Aviat Networks 3ECJ68W7P ISM Band Digital Radio User Manual CERTIFICATE OF COMPLIANCE
Aviat Networks ISM Band Digital Radio CERTIFICATE OF COMPLIANCE
Users Manual
Rhein Tech Laboratories 360 Herndon Parkway Suite 1400 Herndon, VA 20170 http://www.rheintech.com Client: Model: Standards: FCC ID: Report No: Stratex Networks, Inc. Velox LE 2450 FCC 15.247/ IC RSS-210 RLW-3ECJ68W7P 2003205 APPENDIX I: MANUAL Please see the following pages. Page 52 of 63 Orion and MDR Digital Radios Orion and MDR Digital Radios User Manual Document Number: 862-01881 862-01881 Issue 13 Page 1 Orion and MDR Digital Radios Issue Status Issue 10 11 12 12c 13 Revised Pages/Amendments 31 General – terminology definition PER used instead of BER to remove interpretation ambiguity between Block Error Rate and Bit Error Rate. Note Block (equivalent to packet) concept is still maintained within sections describing G.826 parameters to maintain consistency with G.826 terminology. MIB Description chapter added, RESET Button Additions, chapter on setup of a serial connection between a PC/Laptop and the Element Management Port, IP network address description diagrams. Amendments related to customer furnished equipment, RF Unit temperature range update, Maintenance and Ordering section updates, Appendix added regarding Antennas. Update on RESET Button functionality description, MIB definition additions, product receive sensitivity level adjustment, FCC notice updates (Warning – this page, Antenna Information – Appendix E), NMS picture update. Appendix D Digital Indoor Unit firmware Upgrade Notice added. Appendix B MIB Elements ResetAllRFPerfomanceData and ResetAllG826 deprecated. Added detail for new MDR2400 RF Unit Added detail for new Digital Indoor Unit – balanced and unbalanced connectors Added detail for Orion 5825 – SR radio (16 QAM radio), 1+1 system. Changed to American English. Updated MIB as well as NMS, now JAVA based. Support for Windows XP, 2000 added. Added ftp firmware upload, Appendix G Added text required by the ATCB with regards to the Orion 5825 – SR. Added additional text required by the ATCB to adhere to FCC requirements. Added description of per trib line code selectivity for T1 interfaces. See Section 2.3.1. Added Appendix describing the Orion5810i and Orion2410i Indoor RF units. Add text to describe the Orion5810-SRi and Orion2410-Sri and changes requested by Rheintech. Add changes requested by ATCB. (Tx power of +25dBm for Orion5810i) Add text to describe the Orion 50 Digital Indoor Unit and the Orion2450 RF Unit. 862-01881 Issue 13 Page 2 Orion and MDR Digital Radios FEDERAL COMMUNICATIONS COMMISSION NOTICE The equipment has been tested and found to comply with the limits for a Class A digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. WARNING- To comply with FCC RF exposure limits, the antennas for this transmitter must be fix-mounted to provide a separation distance of 2 meters (6.6 ft) or more from all persons to satisfy RF exposure requirements. Equipment installation and use This equipment must be professionally installed. The operator of the spread spectrum or digitally modulated intentional radiator, or the installer if the equipment is professionally installed, is responsible for ensuring that the system is used exclusively for fixed, point-to-point operations. NOTE 1 The MDR2400 frequency output must be limited to between 2412MHz and 2458MHz and the power to a maximum of +22dBm (2412-2426MHz) and +18dBm (2458MHz) for the required antennas for compliance to FCC standards, U.S. only. NOTE 2 The center frequencies of the ORION5850 radio is limited by firmware between 5731MHz and 5844MHz as outlined in Sections 2.2.1.4 and 2.2.1.5 and the transmit power is limited to +24dBm. The device must be used with one of the antennas listed below to comply with FCC standards: 1) Gabriel Electronics parabolic antenna, model number SSP2-52B 2) Harris Corporation flat panel antenna, model number MT-20004. NOTE 3 The center frequencies of the ORION5810i radio is limited by firmware between 5735MHz and 5840MHz as outlined in Section 2.2.1.1 and the transmit power is limited to +25dBm. The device must only be used with the antenna listed below to comply with FCC standards: 1) Gabriel Electronics parabolic antenna, model number SSP2-52B INDUSTRY CANADA NOTICE This device has been designed to operate with an antenna having a maximum gain of 33 dBi. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Exposure of Humans to RF Fields The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Health Canada's website: www.hc-sc.gc.ca/rpb 862-01881 Issue 13 Page 3 Orion and MDR Digital Radios Publication Number: 862-01881 Issue 13 October 2003 © 2003 Stratex Networks The information contained herein is the property of Stratex Network and is supplied without liability for errors or omissions. No part may be reproduced, used or disclosed except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction, use and disclosure extend to all media in which this information may be embodied, including magnetic or electronic storage etc. 862-01881 Issue 13 Page 4 Orion and MDR Digital Radios Table of Contents Page INTRODUCTION 10 1.1 Radio Description 10 TECHNICAL DESCRIPTION 12 2.1 2.2 System Overview RF Unit 12 12 2.2.1 Frequency plans 13 2.2.2 RF Power Output Options 18 2.2.3 2.3 MDR24/5800, Orion24/5810i and Orion 24/5850 RF Units MDRMTE, MDRMETU, Orion10, Orion25, Orion50 Digital Indoor Unit 18 19 2.3.1 Payload Interface Options 20 2.3.2 1+1 Redundancy Protected Payload System 21 2.3.3 Digital Indoor Unit Status LEDs 21 2.3.4 Reset / Configuration Button 22 2.3.5 Service (Wayside) Serial Data Channel 23 2.3.6 Element Manager Port 24 2.3.7 10BaseT Ethernet RJ45 Port (10/100BaseT on Orion 50 DIU) 24 2.3.8 DIU/RFU Link LED 24 2.3.9 DIU/RFU Data Interconnect RJ45 24 2.3.10 DIU/RFU Power Interconnect 25 2.3.11 Auxiliary In/Out Port 25 2.3.12 DIU DC Power Input 25 2.3.13 Fuse Holder 25 2.3.14 ON/OFF Switch 25 2.3.15 Ground Terminal 25 PLANNING 26 3.1 System Type Selection 26 3.1.1 3.2 3.3 3.4 3.5 Antenna selection Site Evaluation Multipath Effects Interference Considerations Microcell Backhaul Applications of MDR / Orion Digital Radios 26 28 28 29 30 3.5.1 Setting the Transmitted Power Levels 30 3.5.2 Frequency Multiplexing 30 3.5.3 Antenna Isolation 30 INSTALLATION 31 862-01881 Issue 13 Page 5 Orion and MDR Digital Radios 4.1 4.2 Customer Furnished Tools and Equipment Digital Indoor Unit 32 33 4.2.1 Introduction 33 4.2.2 Installing the Digital Indoor Unit in a Rack 33 4.2.3 Connecting a DC Power Supply 34 4.2.4 Balanced Payload Data : DB25 35 4.2.5 Balanced Payload Data : RJ48 (Orion 10 and Orion 25 Only) 36 4.2.6 Unbalanced Payload Data : BNC 36 4.2.7 Connecting Auxiliary In/Out (Optional) 36 4.2.8 Connecting the Service (Wayside) Serial Channel (Optional) 37 4.2.9 4.3 Connecting the Element Manager Port RF Unit 38 38 4.3.1 4.4 RF Connection Interconnection Cable Installation 38 39 4.4.1 INTERCONNECTION CABLE WIRING DESCRIPTION 41 ANTENNA ALIGNMENT AND SOFTWARE SETUP 42 5.1 5.2 B.1 Installation Equipment Required Information Required Antenna Alignment 42 42 42 5.2.1 Introduction 42 5.2.2 Alignment Procedure 42 5.2.3 5.3 5.4 Set Transmitted Power Level Software Setup Functional Test 44 45 45 5.4.1 5.5 5.6 Link Bit Error Rate Performance Test MDR / Orion Installation Record MDR / Orion Test Record 45 46 47 NMS SOFTWARE 48 6.1 6.2 6.3 6.4 Scope Introduction System requirements Installing the NMS 48 48 49 49 6.4.1 JRE Installation 49 6.4.2 NMS Installation 49 6.4.3 6.5 NMS Un-Installation Help documentation 50 50 MAINTENANCE INFORMATION 51 TECHNICAL DATA 52 8.1 Environmental Requirements 52 862-01881 Issue 13 Page 6 Orion and MDR Digital Radios 8.1.1 Outdoor Equipment 52 8.1.2 8.2 8.3 8.4 8.5 Indoor Equipment Mechanical Information for Outdoor Equipment Mechanical Information for Indoor Equipment Power Supply Requirements Electrical Performance 52 52 52 52 53 8.5.1 General Characteristics 53 8.5.2 Transceiver Characteristics 57 8.5.3 RF Interface 58 8.5.4 Payload Data Interfaces 58 8.5.5 Ethernet Traffic Interface 59 8.5.6 Auxiliary Input Interface (CONTACT CLOSURE) 59 8.5.7 Auxiliary Output Interface 60 8.5.8 Wayside channel interface 60 8.5.9 Element Manager Port Interface 60 8.5.10 Indoor/RF Unit Interface 8.6 Ordering Information 60 62 APPENDIX: ELEMENT MANAGER PORT POINT-TO-POINT SERIAL COMMUNICATIONS SETUP 83 A.1 A.2 Adding a Modem : Windows NT Adding Dial-up Networking : Windows NT 83 88 A.2.1 A.3 A.4 A.5 To add dial-up networking Adding a Modem : Windows 95/98 Adding Dial-up Networking : Windows 95/98 Adding Dial-up Networking : Windows 2000 / Windows XP 88 93 95 97 A.5.1 To add dial-up networking 97 APPENDIX: MANAGEMENT OF THE MDR2400-SR MDR5800-SR AND THE ORION 5825-SR 104 B.1 B.2 B.3 SNMP and the MDR / Orion The MIB Elements – OID (Object ID) DESCRIPTIONS The MIB elements – TRAP DESCRIPTIONS 104 106 121 APPENDIX: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW PINGING OF A ‘REMOTE’CONFIGURED DIGITAL INDOOR UNIT 123 C.1 C.2 IP CONFIGURATION OF THE MDR / Orion – ROUTING CONFIGURATION IP CONFIGURATION OF THE MDR / Orion – BRIDGING CONFIGURATION 123 125 APPENDIX: MDR5800 HARDWARE VERSION 1, 2.X DIFFERENCES, COMPATIBILITY SUMMARY 126 APPENDIX: FIXED ANTENNAS 129 E.1 MDR5800 129 862-01881 Issue 13 Page 7 Orion and MDR Digital Radios E.2 E.3 E.4 Orion5810i Orion5850 MDR2400, Orion2410i and Orion2450 129 129 129 APPENDIX: USEFUL WEB LINKS 130 APPENDIX: MDR / ORION SCALABLE 1-TO-4/8 E/T1 / 10 BASE-T ETHERNET FUNCTIONALITY 131 APPENDIX: MDR / ORION FTP FIRMWARE UPLOAD 132 APPENDIX: GETTING STARTED GUIDE 134 I.1 I.2 I.3 I.4 Checklist for Bench Testing (without a PC) Interpretation Action One Page Set-up for T1/E1 Bench Test (without a PC) 134 135 135 136 APPENDIX: 1+1 PROTECTION SYSTEM OPERATION 138 J.1 Introduction 138 J.1.1 J.2 System Description Technical Description 138 138 J.2.1 System Overview 138 J.2.2 J.3 J.4 System Configuration System functional description Installation 139 141 142 J.4.1 Hardware Installation 142 J.4.2 J.5 Radio Software Configuration System Verification 143 144 APPENDIX: INDOOR RF UNITS ORION2410I, ORION5810I 145 K.1 K.2 K.3 K.4 Description Steps to install the Indoor RF Unit: RF Connection Interconnection Cable Installation 145 145 146 146 862-01881 Issue 13 Page 8 Orion and MDR Digital Radios List of Abbreviations BIT AIS PER DC DCE DIU DRL DRS DTE GUI ISM LED LOS Mbps N.C N.O NMS PC RF RFU RSSI SNMP Built-in-Test Alarm Indication Signal Packet (or Block) Error Rate Direct Current Data Communications Equipment Digital Indoor Unit Digital Radio Link Digital Radio Station Data Terminal Equipment Graphical User Interface Industrial, Scientific and Medical Light Emitting Diode Loss of signal Megabits per second Normally-closed Normally-open Network Management System Personal Computer Radio Frequency RF Unit (Prefix I or O for Indoor or Outdoor type) Received Signal Strength Indication Simple Network Management Protocol 862-01881 Issue 13 Page 9 Orion and MDR Digital Radios 1 Introduction 1.1 Radio Description The MDR24/5800-SR and Orion24/5810-SRi are ISM band digital radio systems that provide short to medium range, point-to-point digital communication with high data security at rates of T1, 2T1 or 4T1. Alternatively, the radio can be software configured to convey E1, 2E1 or 4E1. The radio can also be configured to bridge or route IP via a 10BaseT port. The data rates scale depending on the number of enabled T1/E1 tributaries and whether the data is being bridged or routed. The products make use of spread spectrum technology and may be operated license-free in the 2.4GHz and 5.8GHz ISM bands. The Orion 24/5825–SR and Orion24/5050–SR are similar radios also operating in the 2.4 and 5.8GHz ISM bands respectively. Modulation can be switched between 16 and 32 QAM with digital output scalable up to 16T1/E1 depending on the specific radio. The radios are ideal for applications such as: • Cellular/PCS base station interconnects. • Telecommunications companies, cellular operators and private carriers. • State Local and Federal Government communication systems. • Video surveillance data distribution. • Power utilities. • Petroleum/gas collection companies. • Rural communications. • Emergency/disaster telephone service restoration. • Internet distribution. The radio consists of two main parts: • An RF Unit operating in the 2.4 GHz or 5.8 GHz ISM frequency bands. This could be an MDR2400ET, MDR5800, Orion2410i, Orion5810i or an Orion 5850 unit. The units with an “i” suffix is 1U Indoor RFUs. • A Digital Indoor Unit, available with a Telecommunications (0 to 16T1/E1 depending on the radio) interface and a Data interface (10BaseT Ethernet). This could be an MDRTE, an MDRETU (75 Ohm BNC), Orion10, Orion25 or an Orion50 (10/100BaseT) unit. All DIUs operate with the MDR2400ET, MDR5800 and Orion24/5810i RFUs. Only the Orion type DIUs operate with the Orion type RFUs. For the Orion DIUs, the numerical value in the unit name roughly resembles the maximum data capacity of the unit. Interconnection between the RF Unit and Digital Indoor Unit is achieved using a lowcost UV-protected STP (Screened Twisted Pair: 4 pairs) data cable and a UVprotected 2-core power cable. The split Digital Indoor Unit and RF Unit configuration is used for the lowest loss between the antenna and the transceiver, thereby ensuring optimal long-range performance. The RF Units use a Type-N RF (female) output connector for connection to a coaxial cable jumper when co-located with a 2.4 GHz or a 5.8 GHz antenna for applications where long range is required. 862-01881 Issue 13 Page 10 Orion and MDR Digital Radios The RF Unit can also be located remote from the antenna (tower base or indoor mounted). The RF connector is then connected to the antenna via a coaxial transmission line. An optional indoor rack mounting adapter is available for mounting the RFU, indoors. The system is available for use in FCC regulated countries. Model variants Table 1. MDR24/5800-SR- and Orion24/5810SRi model variants Model Number Interfaces Antenna Coupling MDR2400-ETNor Orion2410-SRiETN N x T1/E1 10BaseT Ethernet (N = 1, 2 or 4) N-type Female MDR5800-ETN or Orion5810-SRiETN N x T1/E1 10BaseT Ethernet (N = 1, 2 or 4) N-type Female Table 2. Orion 24/5825-SR model variants Model Number Interfaces Antenna Coupling Orion 2425-ET8 8 x T1 / 8 x E1 10BaseT Ethernet N-type Female Orion 5825-ET8 8 x T1 / 8 x E1 10BaseT Ethernet N-type Female Table 3. Orion 24/5850-SR model variants Model Number Interfaces Antenna Coupling Orion 2450 - SR 10/100BaseT Ethernet only or 1 - 16 E1/T1 10/100BaseT Ethernet N-type Female Orion 2450 - SR 10/100BaseT Ethernet only or 1 - 16 E1/T1 10/100BaseT Ethernet N-type Female Refer to section 8.6, page 62 for ordering details. The Network Management System provides control and management of the product. SNMP support via an SNMP agent in the Digital Indoor Unit ensures open network management compatibility. Comprehensive data and RF loop-back functions ensure that the system is easy to install and maintain. 862-01881 Issue 13 Page 11 Orion and MDR Digital Radios 2 Technical Description 2.1 System Overview A digital radio link (DRL) consists of a pair of MDR / Orion radio stations. MDR2400, MDR5800 or Orion 5850 OU MDR / Orion IU User Data MDR2400, MDR5800 or Orion 5850 OU MDR / Orion IU User Data The radio stations consists of two main parts: • An RF Unit operating in the 2.4GHz or 5.8 GHz ISM frequency bands. The RF Unit provides the radio transceiver functionality by accepting radio link data from the Digital Indoor Unit and converting it to the 2.4GHz or 5.8 GHz ISM frequency band using spread spectrum or QAM modulation. The received signal is demodulated and transmitted to the Digital Indoor Unit in a digital format. • A Digital Indoor Unit, available with 0, 1, 2, 4, 8 or 16 T1 or E1 data interfaces (choice of T1 or E1 is software selectable). The Digital Indoor Unit combines nT1 or nE1 data with Wayside Service Channel serial data and link IP data to be transmitted across the radio link. The Digital Indoor Unit also provides power to the RF Unit. The E1/T1 data interface is provided through an optional removable Interface Card. Interconnection between RF Unit and Digital Indoor Unit is achieved using low cost data and power cables. 2.2 RF Unit The MDR2400, MDR5800, Orion2410i and Orion5810i RF Units make use of Spread Spectrum modulation technology for license-free operation in the 2.4GHz and 5.8 GHz ISM bands. The Orion2450 RF Unit uses three software selectable bandwidths for license-free operation in the 2.4 GHz ISM band. The Orion5850 RF Unit uses three software selectable bandwidths for license-free operation in the 5.8 GHz ISM band. The Orion2410i and Orion5810i RFUs are MDR2400 and MDR5800 RFUs respectively, that have been repackaged into 1U units that should be used in indoor unit applications only. Please refer to Appendix K for more detail. For operation, the ISM bands are divided into upper and lower frequency sub-bands. A ‘High Band’ RF Unit transmits in the higher frequency sub-band and receives in the lower frequency sub-band, while a ‘Low Band’ RF Unit transmits in the lower sub-band and receives in the higher sub-band. An MDR / Orion radio link will use a ‘Low Band’ RF Unit on one end of the link to communicate with a ‘High Band’ RF Unit on the other end. The RF Units use a Type-N RF output connector for connection to suitable 2.4GHz and 5.8GHz antennas for applications where long range is required. 862-01881 Issue 13 Page 12 Orion and MDR Digital Radios The system is available for use in FCC regulated countries. 2.2.1 Frequency plans The MDR5800, Orion5810i and the Orion 5850 RF Units operate in the 5.725 GHz to 5.850 GHz ISM frequency band with predefined frequency channel plans (termed A, B, C and D). Channel plan D is user selectable / adjustable. The MDR2400, Orion2410i and the Orion2450 RF Units operate in the 2.400 GHz to 2.4835 GHz ISM frequency band with predefined frequency channel plans (termed A, B and D). Channel plan D is user selectable / adjustable. 2.2.1.1 MDR5800 and Orion5810i Frequency Channel Plan A, B and C The channel spacing is based on the bandwidth occupied by the spread spectrum signal (approximately 17 MHz) and is used to optimise link performance. In the case of plan A, plan B and C, note that both RF Units of a link must be set up to the same frequency channel plan (i.e. A, B or C). LOW BAND TRANSMIT AL 5735 HIGH BAND TRANSMIT BL CL 5753 5771 CH 5804 BH AH 5822 5840 Frequency (MHz) Figure 1. MDR5800 and Orion5810i Frequency channel plans A, B and C 2.2.1.2 MDR2400 and Orion2410i Frequency Channel Plan A, B (non-FCC) The channel spacing is based on the bandwidth occupied by the spread spectrum signal (approximately 17 MHz) and is used to optimise link performance. In the case of plan A and B, note that both RF Units of a link must be set up to the same frequency channel plan (i.e. A or B). LOW BAND TRANSMIT AL 2410 BL 2426 HIGH BAND TRANSMIT AH 2458 BH 2474 Frequency (MHz) Figure 2. MDR2400 and Orion2410i Frequency channel plans A and B 862-01881 Issue 13 Page 13 Orion and MDR Digital Radios 2.2.1.3 MDR2400 FCC Compliant Frequency Channels for the U.S. only In countries where FCC compliance is required, only the following frequencies may be used: Low band RF Unit – 2412MHz to 2426MHz, High band RF Unit – 2458MHz. Use frequency plan D (variable frequency) to set the RF Unit. LOW BAND TRANSMIT DL 2412 DL 2426 HIGH BAND TRANSMIT DH 2458 Frequency (MHz) Figure 3. MDR2400 FCC Compliant Frequency Channels for the U.S. only 2.2.1.4 Orion 5850 Frequency Channels Plan A, B and C (FCC Compliant) The channel spacing is based on the transmit bandwidth, either 3 MHz, 6 MHz, 10 MHz or 14 MHz, software selectable. Different bandwidths can be selected dependent on the optimum link performance; required system sensitivity versus data transfer rate. Only channel frequencies that are FCC compliant can be selected through the configuration software. The channel frequency ranges are programmed into the radio firmware and cannot be adjusted by the user. The radios were tested and approved for FCC compliance with the frequency ranges below, see Figure 4. Low band RF Unit: Modulation Type Lowest Center Freq. (MHz) Highest Center Freq. (MHz) 8.46Mbps / 16-QAM 5731 5774 16.93 Mbps / 16-QAM 5732 5773 25.39 Mbps / 16-QAM 5734 5771 50.78 Mbps / 32-QAM 5736 5769 High band RF Unit: Modulation Type 862-01881 Issue 13 Lowest Center Freq. (MHz) Highest Center Freq. (MHz) Page 14 Orion and MDR Digital Radios 8.46Mbps / 16-QAM 5801 5844 16.93 Mbps / 16-QAM 5802 5843 25.39 Mbps / 16-QAM 5804 5841 50.78 Mbps / 32-QAM 5806 5839 NOTE 1 Both RF Units in a link must be set to the same frequency channel plan (i.e. A, B, C or D) and modulator type. Also note that the frequencies differ for different transmit bandwidths, i.e. the frequency of channel A changes according to the transmit bandwidth. NOTE 2 Figure 4 reflects all the frequency bands that could be obtained with the ORION5850 RFU. Pre-programmed frequency ranges in the radio firmware prevent the user from selecting transmission options that will not meet FCC requirements. Low Transmit Band 5731 High Transmit Band 5774 5801 5844 Frequency [MHz] Figure 4. Orion 5850 Frequency channel plans A, B and C. Refer to NOTE 2 above with regards to FCC standards compliance of the different band plans. 2.2.1.5 Orion 2450 Frequency Channels Plan A, B and C (FCC Compliant) The channel spacing is based on the transmit bandwidth, either 3 MHz, 6 MHz, 10 MHz or 14 MHz, software selectable. Different bandwidths can be selected dependent on the optimum link performance; required system sensitivity versus data transfer rate. Only channel frequencies that are FCC compliant can be selected through the configuration software. The channel frequency ranges are programmed into the radio firmware and cannot be adjusted by the user. The radios were tested and approved for FCC compliance with the frequency ranges below, see Figure 4. Low band RF Unit: Modulation Type Lowest Center Freq. (MHz) Highest Center Freq. (MHz) 8.46Mbps / 16-QAM 2405 2429 16.93 Mbps / 16-QAM 2406 2428 25.39 Mbps / 16-QAM 2408 2426 50.78 Mbps / 32-QAM 2410 2424 862-01881 Issue 13 Page 15 Orion and MDR Digital Radios High band RF Unit: Modulation Type Lowest Center Freq. (MHz) Highest Center Freq. (MHz) 8.46Mbps / 16-QAM 2444 2469 16.93 Mbps / 16-QAM 2445 2468 25.39 Mbps / 16-QAM 2447 2466 50.78 Mbps / 32-QAM 2451 2463 NOTE 1 Both RF Units in a link must be set to the same frequency channel plan (i.e. A, B, C or D) and modulator type. Also note that the frequencies differ for different transmit bandwidths, i.e. the frequency of channel A changes according to the transmit bandwidth. NOTE 2 Figure 4 reflects all the frequency bands that could be obtained with the ORION2450 RFU. Pre-programmed frequency ranges in the radio firmware prevent the user from selecting transmission options that will not meet FCC requirements. Low Transmit Band 2405 High Transmit Band 2429 2444 2469 Frequency [MHz] Figure 5. Orion 2450 Frequency channel plans A, B and C. 2.2.1.6 Frequency Channel Plan D (FCC Compliant) Frequency plan D allows independent control of transmit and receive frequencies. This allows a flexible frequency plan and can be used to overcome interference in the 2.4GHz and 5.8 GHz ISM bands. The frequencies that can be used in the lower or upper sub-bands can be selected in 1 MHz increments. Performance degradation can be expected when operating using channel plan D mode with the chosen frequencies close to the sub-band edges i.e. a choice of one of the high frequencies in the lower sub-band and one of the lower frequencies in the upper sub-band. The allocation of Channel plan D frequencies is shown in Table 4, Table 5 and Table 6.The Orion 24/5850 RF units have up to four different sets of minimum and maximum frequencies, which are determined by the data rate setting of the RFU. Only channel frequencies that are FCC compliant can be selected through the configuration software. The channel frequency ranges are programmed into the radio firmware and cannot be adjusted by the user. 862-01881 Issue 13 Page 16 Orion and MDR Digital Radios The radios ware tested and approved for FCC compliance with the frequency ranges below, see Figure 4. Table 4. MDR2400 and Orion2410i Channel plan D channel frequencies Sub-band Center Frequency (MHz) 2410-2426 2458-2474 NOTE the allowable operation range in FCC countries, page 14. Table 5. MDR5800 and Orion5810i Channel plan D channel frequencies Sub-band Center Frequency (MHz) 5735-5771 5804-5840 Table 6. Orion 5850 Channel plan D channel frequencies RF BW [MHz] / Data Rate [kbps] Lower Sub-band Upper / Higher Sub-band 2.6 / 8464 5731-5774 5801-5844 5.4 / 16928 5732-5773 5802-5843 8.0 / 25392 5734-5771 5804-5841 14.0 / 50784314 5769-5769 5806-5839 Center Frequency (MHz) Table 7. Orion 2450 Channel plan D channel frequencies RF BW [MHz] / Data Rate [kbps] Lower Sub-band Upper / Higher Sub-band 2.6 / 8464 2405-2429 2444-2469 5.4 / 16928 2406-2428 2445-2468 8.0 / 25392 2408-2426 2447-2466 14.0 / 50784314 2410-2424 2451-2463 Center Frequency (MHz) 2.2.1.7 Orion 24/5850 Modulator Types The Orion 24/5850 can operate with different modulator types, the trade-offs being better radio performance versus higher data throughput. The changes can be made via software, using either the Orion NMS / GUI or an SNMP client application. 862-01881 Issue 13 Page 17 Orion and MDR Digital Radios Modulator types and frequency bands that were tested and approved for compliance with FCC regulations are specified in Sections 2.2.1.4 and 2.2.1.5. Table 8. Orion 24/5850 Modulator Types Data Rate [kbps] Modulation type Raw data throughpu t [bit/sec] Typical Payload Approx. RFU output spectrum BW 8464 16-QAM 8 464 052 4T1/E1 + 150kbit Ethernet 2.6 MHz 16928 16-QAM 16 928 105 8T1/E1 + 150kbit Ethernet 5.4 MHz 25392 16-QAM 25 392 157 8T1/E1 + 9.5Mbit Ethernet 8 MHz 50784314 32-QAM 50784314 46 Mbit/s Ethernet or 16 T1/E1 + 14 Mbit/s Ethernet 14 MHz NOTE 1: Changing the modulator type of an Orion 24/5850 RF Unit may take up to 30 seconds. During this period, the link will not be available. Changing the RFU modulator type does not support Auto Recovery thus; the modulator type of the remote station must be changed before the modulator type of the local station is changed. 2.2.2 RF Power Output Options The RF Unit is designed for use in countries that have adopted FCC standards. It is possible to adjust the output power on the RFU using the supplied NMS software or a SNMP Management application. The FCC standards for the MDR2400 unit require a limited output power as stated on page 2, U.S. only. NOTE 1 The firmware on the Orion and MDR type RFUs will not accept power level settings that fall outside the FCC compliant levels. 2.2.3 MDR24/5800, Orion24/5810i and Orion 24/5850 RF Units The RF Units transmit and receive RF signals through a diplexer interfaced via an RF cable to an external antenna. The unit has a type-N connector for connection to the RF cable used between the RFU and the antenna. The RF Unit houses the following main parts: a. Transmit/Receive Modules b. Baseband Modulator/Demodulator Circuitry c. Microcontroller/Framing & Buffering Circuitry d. Power Amplifier e. Diplexer 862-01881 Issue 13 Page 18 Orion and MDR Digital Radios 2.3 MDRMTE, MDRMETU, Orion10, Orion25, Orion50 Digital Indoor Unit The Digital Indoor Unit is designed for mounting in a 19” rack, occupying a 1U slot. It can also be used as a table-top system. The Digital Indoor Unit accepts n x T1/nE1 user payload channels and combines it with Wayside Service Serial Data and IP data to be transmitted across the radio link. The Digital Indoor Unit is fitted with a DC power supply. There are five types of Digital Indoor Units: An MDR 120 Ohm (scalable up to 4 T1/E1), an MDR 75 / 120 Ohm (scalable up to 4 T1/E1), an Orion 10 Digital Indoor Unit (Orion 25 with only up to 4 T1/E1) an Orion 25 Digital Indoor Unit (scalable up to 8 T1/E1) an Orion 50 Digital Indoor Unit (with optional 16 T1/E1 interface card) The MDRMTE and MDRMETU Digital Indoor Units can operate with the MDR2400, MDR5800, Orion2410i and Orion5810i RF Units. The Orion 10 / 25 and 50 Digital Indoor Unit is used with the Orion 24/5850 RF Unit, but can also support the MDR24/5800, and Orion24/5810i RFUs if the appropriate firmware version is loaded on the Digital Indoor Unit. Figure 6. 120 OHM MDR MTE DIU front panel. Figure 7. 75/120 OHM MDR MTE DIU front panel. 862-01881 Issue 13 Page 19 Orion and MDR Digital Radios Figure 8. 120 OHM / 75/120 OHM MDR MTE DIU back panel. Figure 9. ORION25 DIU front panel. Payload Interface Card Reset button Status LEDs 10/100BaseT Network Socket AUX Port DIU DC In Fuse Ground Terminal RF-Unit Data RF Unit DC Out Figure 10. ORION50 DIU front panel with and without payload interface panel. 2.3.1 Payload Interface Options The Digital Indoor Unit can be configured for nT1 or nE1 operation. MDR-Type and Orion10 type DIU: • 1, 2, or 4 x T1 (1.544 Mbps) or E1 (2.048 Mbps) Orion25 type DIU: • 1, 2, 4 or 8 x T1 (1.544 Mbps) or E1 (2.048 Mbps) Orion50 type DIU: 862-01881 Issue 13 Page 20 Orion and MDR Digital Radios • None • 1 - 16 x T1 (1.544 Mbps) or E1 (2.048 Mbps) For T1 connectivity, bipolar AMI or B8ZS line coding is software selectable. For E1 connectivity, bipolar AMI or HDB3 line coding is software selectable. Line coding on the Orion 25 DIU may be selected separately for tributary channels 1 to 4 and 5 to 8 when used with an Orion 24/5850 RFU. Line coding and impedance may be selected on a per tributary basis for the Orion 50 DIU with a tributary data interface. The payload can be connected on: • Unbalanced 75 Ohm BNC connectors, 75/120 Ohm DIU only (RX= In, TX= Out). • Balanced 120 Ohm, 25 way D-type connectors (refer to paragraph 4.2.4 for the pin outs). • Balanced RJ48C connectors on the Orion 25 (refer to paragraph 4.2.5 for the pin outs). NOTE A special version of the MDR Digital Indoor Unit exists that allows the user to select AMI or B8ZS line encoding on a per-trib basis for T1 connectivity. These Digital Indoor Units are marked as Version 2.1AT. Line codes can be selected on a per-trib basis using the Orion NMS software application. In the Payload Configuration window: 1. Set the Digital Indoor Unit Payload interface to T1 mode and Apply. 2. Refresh the information displayed in the window. 3. Select the desired Line Code next to each trib and Apply. Hardware modified to implement this feature can ONLY work with special DIU firmware – contact the distributor for details. 2.3.2 1+1 Redundancy Protected Payload System The MDR and Orion radios can be used in a 1+1 redundant mode system to protect the tributary payload data carried over a radio link. This system detects the quality of the link over which it is receiving data and allows switching between two parallel radio links to protect the user data against link failures. Please refer to Appendix I, or the Protection Kit user manual, doc. no. 862-02236 for detail on the functioning of this system. 2.3.3 Digital Indoor Unit Status LEDs The Digital Indoor Unit LED functionality is described as follows: SYSTEM Green OK, Orange (RFU/DIU Comms Error), Red (RFU/DIU Comms Down) 862-01881 Issue 13 Page 21 Orion and MDR Digital Radios PAYLOAD Green OK, Orange (AIS Detected), Red (LOS Detected) RF LINK Green OK, Orange (FEC Correcting Errors), Red (FEC unable to correct errors) In ALL cases flashing red and orange LEDs imply historic alarm conditions (The alarm can be cleared using the front panel button ‘position 1’ : see next section). Flashing LED’s and yellow indicators (Orion NMS) may also be cleared by clicking on the “Clear Alarms” button in the Orion NMS Main Radio Window. 2.3.4 Reset / Configuration Button The functionality of the Reset Button is described below. These functions are used to set up the radio. A paper clip or similar “probe” can be used to push the “reset / configuration button”. The count value / LED count at which the button is released, will be the "new" configuration / state of the DIU. The count value is determined by the different LEDs lighting up. ‘Position 1’ being RF Link LED (Green), 2 being Payload LED (Green), 3 being System LED (Green), 4 being RF Link LED (Orange), 5 being Payload LED (Orange) and 6 being System LED (Orange) etc. Reset button functions (according to "LED reset" number) 1. Clear Front Panel LEDs (and associated alarms in DIU) 2. Clear Event Log in the Digital Indoor Unit 3. Reset the Digital Indoor Unit (does not reset the non-volatile memory storing the DIU’s configuration parameters) 4. Routed Configuration: Reset the DIU configuration parameters that are stored in non-volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side DIU’ : i.e. for a ROUTED IP configuration, set the Ethernet IP address as 10.11.1.2, Element Manager IP address to 10.12.1.2 5. Routed Configuration: Reset the DIU configuration parameters that are stored in non-volatile memory and configure as a ‘Near Side DIU’ : i.e. for a ROUTED IP configuration set the Ethernet IP address as 10.2.1.2, Element Manager IP address to 10.13.1.2 6. Routed Configuration: If you are not sure how the DIU is configured (NEAR or FAR side DIU), reset it AS IS i.e. reset the ‘Near Side DIU’ or ‘Far Side DIU’ configuration parameters depending on how the DIU is currently configured. 7. Bridged Configuration: Reset the DIU configuration parameters that are stored in non-volatile memory (BATTERY-BACKED STATIC RAM) and configure as a ‘Far Side DIU’ For a BRIDGED IP configuration, see Appendix C of this document for a description of the default IP addresses. 8. Bridged Configuration: Reset the DIU configuration parameters that are stored in non-volatile memory and configure as a ‘Near Side DIU’. For a BRIDGED IP configuration, see Appendix C of this document for a description of the default IP addresses. 9, 10, 11 RESERVED 862-01881 Issue 13 Page 22 Orion and MDR Digital Radios 12. Set up Digital Indoor Unit with E1 tributaries. 13. Set up Digital Indoor Unit with T1 tributaries. 14. Deactivate buttons 4 onwards. 15. Toggle SNMP and FTP Servers ON/OFF (V3.00+ firmware) 16. DHCP ON (V3.00+ firmware) 17. DHCP OFF (V3.00+ firmware) 18. Ethernet MAC learning enabled via front panel 19. Transparent ethernet mode enabled via front panel 20. EEprom erased via front panel (MDR Only) 21. RFU back-to-back enable / disabled toggle via front panel NOTE All buttons can be REACTIVATED (i.e. undoing a 14 'reset') by doing a poweron reset while holding the front-panel Reset Button in for 1 LED count. NOTE POSITIONS 4, 5, 6, 7 and 8 RESET THE DIGITAL INDOOR UNIT TO FACTORY DEFAULTS – THESE RESETS ARE TYPICALLY ONLY USED ONCE (THESE CHOICES RESET CERTAIN ADJUSTABLE PARAMETERS IN NON-VOLATILE MEMORY IN THE DIGITAL INDOOR UNITS). IF CHANGES ARE MADE TO THE CONFIGURATION PARAMETERS AND THE USER DOES NOT WANT THESE TO CHANGE WHEN A UNIT IS RESET, THE DIGITAL INDOOR UNIT CAN BE POWER-CYCLED OR POSITION ‘3’ MUST BE USED E.G. THIS TECHNIQUE IS USED IF THE IP ADDRESSES ASSOCIATED WITH THE NETWORK INTERFACES ARE ADJUSTED – THE PROCESSOR NEEDS TO BE RESET TO ALLOW THE CHANGE/S TO BE IMPLEMENTED. IF YOU OVER-RUN THE SELECTION YOU REQUIRE, CONTINUE UNTIL THE LEDs GO BLANK – THEN, START AGAIN (OPTION AVAILABLE WITH RELEASE 2+ OF DIU FIRMWARE). 2.3.5 Service (Wayside) Serial Data Channel 862-01881 Issue 13 Page 23 Orion and MDR Digital Radios This port supports asynchronous full duplex, serial data transfer at a speed of 115200 bps. The interface type is RS-232 configured as DCE (Data Communications Equipment). Handshaking can be None, Hardware. 2.3.6 Element Manager Port This port is used for communication with the NMS software or with an SNMP manager to control the MDR system. The port must be connected to a serial port (configured for a speed of 115200 bps) on a personal computer to use the NMS software. The interface type is RS-232 configured as DTE (Data Terminal Equipment). Hardware handshaking is used. 2.3.7 10BaseT Ethernet RJ45 Port (10/100BaseT on Orion 50 DIU) This port is used for communications with the NMS / GUI software from a laptop / PC or with an SNMP manger to control the system. It can also be connected to a hub for 10BaseT / 10/100BaseT wayside Ethernet throughput. The interface type is DTE (Data Terminal Equipment) and can support Full and Half Duplex Ethernet connections. Select the Ethernet Duplex mode from the following MIB element: 1.3.6.1.4.1.1316.1.1.1.4.16 mdrmteEthernetFullDuplex. Take note that connecting the radio to an Ethernet hub requires the Ethernet interface to operate in Half Duplex mode. 2.3.8 DIU/RFU Link LED This LED indicates if there is a suitable electrical connection between the Indoor and RF Units . 2.3.9 DIU/RFU Data Interconnect RJ45 This receptacle accepts an RJ45 plug that connects to UV-protected STP (Screened twisted pair) cable used between the DIU and the RFU. NOTE that on V1 hardware only the Ethernet Physical interface is checked with this LED, not the RS232/485 interface. The integrity of the RS232/485 interface is checked using the front panel “System LED”. On later versions the RS232/485 interface is no longer used. 862-01881 Issue 13 Page 24 Orion and MDR Digital Radios 2.3.10 DIU/RFU Power Interconnect This connector (socket) is used for power interconnection between the DIU and the RFU. The connection is made using UV-protected 2-core cable. The cable is connected to a GREEN, two-pin connector, a plug. CAUTION The polarity sense (labelled) must be maintained between the DIU and the RFU. 2.3.11 Auxiliary In/Out Port The auxiliary in/out port is used for remote monitoring and control. The following are provided • Two inputs (for sensing contact closure or opening) are provided to sense site alarm inputs. The states of these alarm inputs can be monitored with NMS, as well as from an SNMP Management Station. • Two relay contact outputs, normally-open and normally-closed contacts, are provided as alarm / auxiliary outputs. Output states are software customised and controlled. The outputs are used to indicate alarm or other states selected by the operator via the NMS or a SNMP Management Station. 2.3.12 DIU DC Power Input This connector (socket) is used for power input to the DIU. The connection is made using 2 or 3-core cable. The cable is connected to a two pin GREY connector on the MDR radio and a THREE pin GREEN connector on the Orion unit - both are plugs. The polarity-sense (labelled) must be observed and implemented. A ground connection is available on the three-pin connector. This ground connection is not required if the ground terminal is connected (2.3.15). 2.3.13 Fuse Holder This holder is used to hold a fuse (2A, slow blow fuse). 2.3.14 ON/OFF Switch This switch is used to control power input to the Digital Indoor Unit (and indirectly the RF Unit). No switch is fitted to the Orion DIU. The unit will start up as soon as the required DC voltage is applied. 2.3.15 Ground Terminal This is used to accept connection to an earth strap, terminated with a crimped earth lug. Refer to the installation chapter for details on wire/earth lug requirements. A ground connection is also available on the three-pin DIU DC power connector. 862-01881 Issue 13 Page 25 Orion and MDR Digital Radios 3 Planning This chapter is aimed at management and planning staff to enable them to assess the requirements for installing an MDR / Orion digital radio link. 3.1 System Type Selection The system uses an RF Unit with a type-N RF output for connection to a range of antennas. The MDR / Orion is aimed at FCC regulated markets. Antenna polarization can used to co-locate multiple systems. Antenna polarization can be used to overcome interference. 3.1.1 Antenna selection The antenna type must be selected before the system is to be installed. The chosen antenna must enable the system to operate with sufficient link fade margin without excessive cost and allow the user’s ‘link availability requirements’ to be met. The main consideration when selecting an antenna is antenna gain measured in dBi. A path loss analysis is highly recommended to determine the antenna gain needed for adequate fade margin. The table below shows antenna selection guidelines for some configurations. The distances are calculated for a 20 dB link fade margin. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (EIRP) is not more than that required for successful communication. Table 9 MDR5800 Antenna Selection Antenna Type Gain (dBi) MDR RFU Typical Distance (Km) Power level (dBm) 0.15 m Flat panel 18 24 0.3 m Flat panel 24 30 24 0.6 m Flat panel 28 80 24 Table 10 Orion5810i Antenna Selection Antenna Type Gain (dBi) MDR RFU Typical Distance (Km) Power level (dBm) Gabriel Parabolic Antenna (SSP 52B) 29 80 25 862-01881 Issue 13 Page 26 Orion and MDR Digital Radios Table 11 Orion5850 Antenna Selection Antenna Type Gain (dBi) MDR RFU Typical Distance (Km) Power level (dBm) 0.6 m Flat panel (MT-20004) 28 80 24 Table 12 MDR2400, Orion2410i and Orion2450 Antenna Selection Antenna Type Gain (dBi) Distance (Km) Power level (dBm) 1.2 m Parabolic Antenna 27 80 18 862-01881 Issue 13 Page 27 Orion and MDR Digital Radios 3.2 Site Evaluation When planning a site for a digital radio link, it is of the utmost importance that you take the operational environment of the proposed site into account. The combined effect of atmospheric environmental factors such as rain and lightning, atmospheric attenuation, signal path obstruction, propagation fading, air temperature gradients, ice build-up, wind and solar radiation can contribute towards reducing the level of performance of the system. The 2.4 GHz and 5.8 GHz bands are not adversely affected by rain, ice or snow. Severely cold and excessively warm climatic conditions outside the scope of the operating temperature range can affect the function of the system, especially the outdoor equipment (see Environmental Characteristics on page 52 of this manual). Also, if masts are not sufficiently rigid, very strong winds can affect the antenna beam alignment and Outdoor equipment reliability due to wind force build-up and/or vibration of the mast-mounted equipment. 3.3 Multipath Effects The effects of multipath propagation can influence the radio. Understanding these effects will help when installing a radio link and maximise the reliability of the link. Multipath fading occurs when the receiving antenna receives not only the direct signal from the transmitting antenna but also a signal from the transmitting antenna that has reflected off the ground or nearby obstacles. The reflected signal takes a longer path to reach the receiver and acts as interference since it is not in-phase with the direct path signal. The amplitude of the interference can be almost equal to that of the direct path signal, thus degrading the performance of the link. Multipath propagation is dependent on transmit frequency and the specific geometry of the link such as antenna heights, distance between the antennas and the local terrain. To counteract multipath propagation, the installer can change the frequency at which the link operates or adjust the height of one or both of the antennas. D ir e c t R F P a t h M D R / O r io n O U M D R / O r io n O U R e f le c t io n P a t h M D R M D R / O r io n I U / O r io n I U U s e r D a ta U s e r D a ta Figure 11. Multipath Effects. 862-01881 Issue 13 Page 28 Orion and MDR Digital Radios 3.4 Interference Considerations The ISM frequency bands are used by other devices that can cause interference to the MDR / Orion radio systems. Interference can be avoided by careful planning of the system installation. The available methods for providing isolation from interfering radiators are the following: • Frequency diversity • Antenna polarization It is recommended to scan the proposed installation areas with a spectrum analyzer prior to installation to establish the presence of interference. The spectrum analyzer feature available on the NMS / GUI may also be used. If interference is detected on the path, the GUI, via laptop connection, can be used to select a new channel plan (A, B, or C) to “steer around the interferer, or to create a new custom channel plan (Plan D) to avoid the interference. SNMP network architecture, if employed, may also be used to make the frequency plan changes. The frequency spectrum should be scanned over a sufficient time period to ensure that periodic transmissions are recorded. Interferers will cause problems if their amplitudes are not more than 20 dB below the intended receive power level. A link path loss calculation should be performed to determine the expected receive power level. The procedure for selecting the optimum antenna polarization and system frequency plan is the following: • Perform a spectral analysis at each site in the link direction using a high gain antenna. • Repeat the spectral analysis for vertical and horizontal polarization. • Select the polarization with the lowest interfering levels as the system antenna polarization. • Consult the MDR / Orion frequency channel plans as shown in section 2.2.1 and select the frequency plan that would operate in an interference-free band. • Install the ‘High Band’ and ‘Low Band’ RF Units at the sites where they would experience the lowest interference in their respective receive bands. 862-01881 Issue 13 Page 29 Orion and MDR Digital Radios 3.5 Microcell Backhaul Applications of MDR / Orion Digital Radios In applications where more than one independent and separate links, need to radiate from a central site, a number of parameters can be taken advantage of, to provide isolation and minimise interference between these links: • Frequency multiplexing • Antenna polarization • Choice of High Antenna Gain It is important to note that these methods only provide isolation between two radio Systems, and that power levels in the separate systems should be balanced to ensure correct operation. 3.5.1 Setting the Transmitted Power Levels To minimise interference, received power levels should be balanced between separate radio links. This means that transmit power levels should be set to provide similar levels of received power, as indicated by the RSSI values of the adjacent receivers at the central site. Power levels are easily adjusted via point and click selection utilizing the provided NMS / GUI, installed on your laptop or via SNMP network architecture. 3.5.2 Frequency Multiplexing The MDR2400, Orion2410i and Orion2450 offers three frequency channel plans, the MDR5800, Orion5810i and the Orion 5850 offers four frequency channel plans. Refer to paragraph 2.2.1 for more detail on the frequency channel plans. A radio link requires two channels (one for transmit and one to receive) to provide full duplex operation. Each radio has a high and a low sub-band, one that it uses for transmission and another for reception. Terminology definition: the ‘High-band RF Unit’ of a system transmits on the higher of the two sub-bands. The ‘Low-band RF Unit’ of a system transmits on the lower of the two sub-bands. A system (link) always has one High Band and one Low Band RF Unit. It is important to note that unwanted transmitted signals in adjacent frequency bands can affect other receivers operating in an adjacent band if insufficient antenna isolation is provided. A solution is to group high-band or low-band RF Units at the central site, rather than group high and lowband RF Units together. 3.5.3 Antenna Isolation Separate links at a central site will have sufficient isolation when radio systems operate outside the radiation beamwidth or side lobes of the system antenna. The achievable isolation can be established by examining the measured radiation patterns of the system antennas. Directional isolation can be used if the antenna radiation is 15 dB or lower relative to the adjacent main beam. Antennas with high directionality will allow reduced angular separation of adjacent systems. Antenna cross-polarization isolation can be used for adjacent radio links, radiating in the same direction. Typical isolation of 30 dB can be achieved using high quality antennas. 862-01881 Issue 13 Page 30 Orion and MDR Digital Radios 4 Installation This chapter describes a recommended installation procedure for the MDR24/5800, Orion24/5810i and the Orion24/5850. Before installation / departure to site 1. Carefully open all shipping boxes and look for any obvious damage that might have resulted during shipment. 2. Do an operational bench test to verify the functionality of the system. 3. Confirm that both radios have the correct IP configuration (refer to page 125, paragraph C.2) for "local" and "remote" sites. Use the provided NMS / GUI installed on a laptop / PC to configure / analyze the radio via a serial / ethernet connection to the DIU element manager port. Local and remote IP addresses labels may be fitted to the DIU’s and can be verified with those listed in the GUI. 4. Both radios should be on the same channel plan (paragraph 2.2.1) and power should be set to an appropriate test level (not muted). 5. NOTE Use at least 60dB attenuation when directly connecting two RFU RF ports. 6. After initial power up and a minute or so of “settle time”, clear any flashing LEDs via the front panel reset button (paragraph 2.3.4) or the GUI. The DIU status LEDs should be green with no errors indicated and remain green for an appropriate time span (at least 1-2 minutes). 7. After satisfactory results, disconnect the units and transfer to the installation site for permanent installation. NOTE It is recommended that the installer have previous experience in installing radio communication equipment or has attended a training course from the supplier for the purpose of understanding how to set-up and configure an MDR / Orion radio. Recommended installation procedure 1. Install the Digital Indoor Unit. 2. Prepare and connect the cables to the Digital Indoor Unit. 3. Install the RF Unit and antenna. 4. Install the Indoor-to-RF Unit interconnection cables (the power and data cables). 5. Turn the Digital Indoor Unit power on. 6. Perform the initial software setup using the supplied NMS application 7. Repeat item 1-5 for the remote site. 8. Align the antennas (use the RSSI voltage on the RFU or the RSSI value from the MIB or the NMS Graphic User Interface to assist with the setup). 9. Perform a functional test and commission the link. 10. Connect to user data. 11. Start the system. Installation of the MDR / Orion elements are described in the following sections: • Installing the Digital Indoor Unit • Installing the RF Unit and Antenna • Installing the interconnection cables 862-01881 Issue 13 Page 31 Orion and MDR Digital Radios 4.1 Customer Furnished Tools and Equipment The following table lists tools and equipment required to install the MDR and Orion radio systems. General, DIU-to-RFU Interconnect • Cable cutting and stripping tools. • Ground lug crimp tools. • 3 mm flat screwdriver - DIU to RFU power cable. • RJ45 crimp tool - DIU to RFU data cable. • Soldering iron. • Ground cable or strap rated at 45A with 5 mm ground lug for grounding the Indoor and RF Units. • Cable ties, used to secure the cables to the mast at regular intervals. DIU • Pozi #2 screwdriver - DIU mounting in a 19" rack and the ground lug. • 7mm Spanner – Attaching the earth cable to the DIU. • 2.5mm Allen key - To change the position of the DIU mounting brackets. • DC power supply cable: minimum 2.5 mm square conductor, rated for 10 A. For connection between the power supply and the Digital Indoor Unit DC connector on the rear panel. (The DC connector is on the front panel of the Orion DIU.) • DIU ground lug: 10-4 (10 square mm for wire and hole big enough for M4 thread) Outdoor RFU • 13 mm wrench / spanner – used for attachment of RFU to mounting bracket and mounting bracket to pole. Also used to close RFU with hinge type connection box. • 2.5 mm Allen key - used to tighten RFU connection box cover fasteners. • RFU ground lug: 10-8 (10 square mm for wire and hole big enough for M8 thread) • Multimeter (recommended) to measure RSSI at RFU during antenna panning. The RSSI level may also be read from the NMS / GUI via laptop connection to the DIU, indoors Indoor RFU • Pozi #2 screwdriver - DIU mounting in a 19" rack and the ground lug. • 7mm Spanner – Attaching the earth cable to the DIU. • 2.5mm Allen key - To change the position of the DIU mounting brackets. • RFU ground lug: 10-8 (10 square mm for wire and hole big enough for M8 thread) • Multimeter (recommended) to measure RSSI at RFU during antenna panning. The RSSI level may also be read from the NMS / GUI via laptop connection to the DIU, indoors 862-01881 Issue 13 Page 32 Orion and MDR Digital Radios Please refer to paragraphs 4.3.1 and 8.5.10 for details on the RF and data cables, which are also customer furnished equipment. 4.2 4.2.1 Digital Indoor Unit Introduction This section describes the recommended installation procedure for the Digital Indoor Unit. The Digital Indoor Unit is designed for mounting in the DIN 41494 (19") racking standard and occupies a 1U high slot. Desktop mounting is also possible. The Digital Indoor Unit’s payload (nT1, nE1 and Ethernet) and Service Channel (‘Wayside serial’) data interfaces and Element Management interface are located on the front panel. Input Power, Auxiliary alarm and ‘DIU/RFU Interconnect’ interfaces are located on the rear panel for the MDR DIU, suitable for rack installations and on the front panel for the Orion DIU, simplifying accessibility. The recommended installation procedure for the Digital Indoor Unit is the following: 1. Install the Digital Indoor Unit in the rack. 2. Ground the Digital Indoor Unit. This is required for safety and to minimise radiated emissions. 3. Connect the DC power supply. There is no ON/OFF switch on the Orion DIU, thus connecting the DC power supply will start up the radio. 4. Connect Payload data ports (front panel). 5. Connect Auxiliary In/Out port (optional). 6. Connect Service Channel (Wayside) serial port (optional). 7. Connect the Element Manager port using the supplied cable (front panel). 4.2.2 Installing the Digital Indoor Unit in a Rack 1. Slide the Digital Indoor Unit into the 19" rack and secure to the rack using four (4) APPROPRIATELY sized bolts for size and rack threads provided. M6 x 18 mm screws are recommended. 2. Ground the Digital Indoor Unit by connecting the ground cable or strap between the station ground and the ground terminal on the Digital Indoor Unit rear / front (Orion) panel. 862-01881 Issue 13 Page 33 Orion and MDR Digital Radios 4.2.3 Connecting a DC Power Supply WARNING – See section 8.4 for specification of the power supply. 1. 2. 3. Observing the polarity of the supply, wire up the supplied power connector cable plug and connect it to the DC supply (Voltage range as indicated on the Digital Indoor Unit) through a minimum 2 A slow blow circuit breaker. Check the supply voltage using a multimeter. Secure the connector screws to the unit. DC Power Connector Pinouts (MDR DIU) Digital Indoor Unit connector: Pin GREY No 2-pin Wieland Type 8213 Socket + Signal DC POWER - DC + DC POWER RETURN DC Power Connector Pinouts (Orion DIU) Digital Indoor Unit connector: GREEN 3-pin Phoenix Type 18.27.87.1 Socket 862-01881 Issue 13 Pin No Signal DC POWER GND GROUND PIN DC POWER RETURN Page 34 Orion and MDR Digital Radios 4.2.4 Balanced Payload Data : DB25 1. Assemble the (nE1) / (nT1) payload data input and output cable. See the table below for Digital Indoor Unit connector pin assignments. 2. Connect the payload data cable to the DB25 connector on the front panel of the Digital Indoor Unit. Standard termination of this port is 120 Ohms. On the Orion 25, 75 Ohms termination is available on request (please contact the factory). On the Orion 50 DIU with the appropriate payload interface card fitted, the termination can be selected on a per tributary basis. NOTE Rx implies IN (signal expected to go INTO the interface), Tx implies RFUT (signal coming out of the interface) Tribs 1-4 are connected on D1 on the Orion10, Orion25 and MDR DIU. In a similar fashion tribs 5-8 are connected on D2 for the Orion 25 radio, that is pin 2 = RTIP6, pin 10 = RTIP5 and so on. This pattern is repeated for Tribs 9 – 16 on connectors D3 and D4 for the Orion 50 16 E1/T1 payload interface card. D-Type Payload Data Connector Pin # 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 862-01881 Issue 13 Pin Name Tributary GND / Earth RTIP2 Direction N/A RX + GND / Earth N/A TTIP2 TX - RRING2 TRING2 RX - TX + GND / Earth N/A GND / Earth N/A RRING1 RX + GND / Earth N/A TRING1 TX - RTIP1 TTIP1 TRING3 TTIP3 RX - TX + TX TX + GND / Earth N/A RRING3 RX+ RTIP3 GND / Earth TTIP4 TRING4 N/A GND / Earth RTIP4 RRING4 GND / Earth RXTXTX+ N/A RX+ RXN/A Page 35 Orion and MDR Digital Radios 4.2.5 Balanced Payload Data : RJ48 (Orion 10 and Orion 25 Only) 1. Assemble the T1 / E1 payload data input and output cable. See the table below for Digital Indoor Unit connector pin assignments. 2. Connect the payload data cables to the RJ48 connectors (numbered 1-8 for tribs 1-8) on the front panel of the Digital Indoor Unit. Standard termination of this port is 110 Ohms. On the Orion10 and Orion25, 75 Ohms termination is available on request (please contact the factory). It is recommended to use a cable that connects to pin 1,2,4, and 5 only since the other pins on the RJ48 are not used to transfer data. NOTE Rx implies IN (signal expected to go INTO the interface), Tx implies RFUT (signal coming out of the interface) RJ48C Socket Pin 3,6 7,8 Description R (Ring 1) T (Tip 1) 50 Ohm terminated R1 (Ring) T1 (Tip) No Connection Direction TX TX N/A RX RX N/A NOTE Use Twisted Pair Cable conductors for pins: 1 & 2, 3 & 6 and 4 & 5. 4.2.6 Unbalanced Payload Data : BNC One of the variants of the MDR Digital Indoor Unit has a set of 75 Ohm BNC’s on the front panel as well as the DB25 connector. • Rx implies IN (signal expected to go INTO the interface) • Tx implies RFUT (signal coming RFUT of the interface) NOTE Tribs are numbered 0-3 on the front panel, but are called 1-4/1-8 in the NMS / GUI. 4.2.7 Connecting Auxiliary In/Out (Optional) The auxiliary in/out port is used to: • Monitor switch-closure events using two isolated inputs. • Control line connections using normally-open and normally-closed relay outputs. Connect the port: 1. Assemble an auxiliary in/out cable using a 15 way D-type male connector according to connector pin assignments shown in Table 13. 862-01881 Issue 13 Page 36 Orion and MDR Digital Radios 2. Connect to the cable Digital Indoor Unit auxiliary in/out connector. 3. Secure the connector using locking screws. NOTE The Orion and MDR Digital Indoor Units are equipped with only two relays. The Normally-Open and Normally-Closed output for each of the two relays are however provided on the Auxiliary Connector for convenience. Table 13. Auxiliary In/Out Connector Pin Outs Digital Indoor Unit connector 15-pin D-type female 15 4.2.8 Pin No 10 11 12 13 14 15 Signal OUTPUT 1 COMMON OUTPUT 1 NORMALLY-OPEN OUTPUT 1 NORMALLY-OPEN OUTPUT 1 NORMALLY-CLOSED OUTPUT 1 NORMALLY-CLOSED OUTPUT 1 COMMON OUTPUT 2 COMMON OUTPUT 2 COMMON OUTPUT 2 NORMALLY-OPEN OUTPUT 2 NORMALLY-OPEN OUTPUT 2 NORMALLY-CLOSED INPUT 1 INPUT 1 RETURN INPUT 2 INPUT 2 RETURN Connecting the Service (Wayside) Serial Channel (Optional) This ‘clear’ serial channel can transport up to 115,200 bps across the radio link. This channel does not interfere with the payload data channels. The port is configured as DCE. 1. Connect the serial data interface cable to the Service channel connector on the Digital Indoor Unit rear panel. The supplied serial data cable can be used to connect to this port after the software setup is completed. 2. See the table below for Digital Indoor Unit connector pin assignments when a custom cable needs to be assembled. 3. Secure the connector using locking screws. Service Channel Connector Pinouts Digital Indoor Unit connector 9-pin D-type Female Connector 862-01881 Issue 13 Pin No Signal TD RD DTR GROUND DSR RTS CTS Page 37 Orion and MDR Digital Radios 4.2.9 Connecting the Element Manager Port The Element Manager port is used to connect the Digital Indoor Unit to a PC/Laptop serial port. This enables the Digital Indoor Unit to be configured using the supplied NMS / GUI software or controlled via a PPP-dialup connection. The port can be connected to using the supplied serial data cable. The port is configured as DTE. NOTE The Ethernet port can also be used to control the DIU via the GUI / SNMP software. 4.3 RF Unit The MDR2400 and MDR5800 outdoor RF Units are also available as 1U indoor RF Units, Orion2410i and Orion5810i, that can be rackmounted in a 1U rack. Before installing the Orion or MDR RF Unit, ensure that a suitable mast is used for the antenna and that the RF Unit installation is firmly in position. The pole diameter must be between 50 and 102 mm or between 2" and 4½". The outdoor unit type RF Unit may also be mounted indoors, utilizing an optional rack mount adapter (not included as a standard item) at the base of a tower for convenient access. However, this as not recommended as a long and expensive RF cable would then be required, compromising system sensitivity and increasing link costs. CAUTION – ENSURE THAT THE POLE IS EARTHED FOR LIGHTNING PROTECTION. Follow these steps to install the RF Unit: 1. Install the system antenna. 2. Adjust the mounting bracket to be slightly bigger than the pole diameter. 3. Secure the mounting bracket to the pole. 4. Secure the RF Unit to the bracket using the screws on each bracket. 5. Connect the RF Unit to the pole electrically by connecting the earth cable or strap between the pole earth and the RF Unit earth point. 6. Connect the type-N RF output connector to the system antenna through an in-line lightning protection unit in areas with lightning activity. 7. Cover the connectors using an ultra violet protective, self-vulcanising tape. 4.3.1 RF Connection 1. The RF port is an N-type female connector. 2. The N-Type connector is used to connect to the antenna, typically using coaxial transmission line. 3. 1/2" or 5/8” coaxial cables are recommended. Coaxial cable that is 7/8” or larger can exhibit moding at 5.8 GHz and is not recommended for 5.8 GHz radios. 862-01881 Issue 13 Page 38 Orion and MDR Digital Radios 4. Do not use right angle N-type connectors with the radios: they may present high loss. 5. Do not use low quality cables. Some cable types, such as RG-8, may have too high a loss at 5.8 GHz. 4.4 Interconnection Cable Installation Follow these steps to install the Digital Indoor Unit to RF Unit interconnection cables. CAUTION - DO NOT OVER TIGHTEN THE CABLE STRAPS ON THE CABLES AND DO NOT FASTEN THE STRAP LOCKING MECHANISM OF THE CABLE STRAP ONTO THE CABLES. 1. 2. On the RFU side, connect an RJ45 plug to the data cable. Place the RJ45 plug into the RJ45 socket in the RF Unit connection box / Indoor RF Unit front panel. On the RFU side, connect the DC power leads within the RF Unit Connection Box / on the Indoor RF Unit front panel. Use the + and - connections. Rear Panel IU/O U LINK RJ45 Socket Front Panel RJ45 Socket IU/OU LINK LOOKING AT THE "RF Unit" CONNECTION BOX (Located on the rear panel of the MDR DIU, front panel of the Orion DIU) 3. 4. 5. 6. 7. If applicable: Close the RF Unit Connection Box Cover using a 2.5mm Allen key. Make sure the rubber gaskets seal correctly over the power and data cables. If applicable: Using cable ties, secure the cable to the pole at regular intervals. On the DIU side, connect an RJ45 plug to the data cable. Place the RJ45 plug into the RJ45 socket in the "RF Unit" connection box. On the DIU side, connect the DC power leads to the supplied GREEN Phoenix plug. Insert this plug into the green socket in the "RF Unit" connection box. The user can see that there is a suitable DIU/RFU data interconnection if the ‘DIU/RFU Link’ LED of the DIU is lit up green. 862-01881 Issue 13 Page 39 Orion and MDR Digital Radios CAUTION - UNDO THE SCREWS OF THE “CONNECTION BOX” IN A UNIFORM MANNER. THIS ENSURES THAT THE “CONNECTION BOX” GASKET MATERIAL RELEASES STRESS UNIFORMLY AND DOES NOT LEAD TO THE SECURING SCREWS BEING BENT DUE TO THE PRESSURE PLACED ON THE CONNECTION BOX LID. 862-01881 Issue 13 Page 40 Orion and MDR Digital Radios 4.4.1 INTERCONNECTION CABLE WIRING DESCRIPTION TOP VIEW (LOCKING TAB UNDERNEATH) RJ-45 PLUG Pin DTE (on DIGITAL INDOOR UNIT) DCE (on RF UNIT) Wiring 4† 5† 7† 8† TxD+ RxD- Orange/White TxD- RxD+ White/Orange RxD+ TxD+ Green/White TxC+ RxC+ Blue/White TxC- RxC- White/Blue RxD- TxD- White/Green RxC+ TxC+ Brown/White RxC- TxC- White/Brown NOTE † VERSION 1 AND 2 RELEASES OF THE HARDWARE (INDOOR AND RF UNITS) CANNOT BE USED INTERCHANGEABLY. FOR VERSION 2 DIU & RFU HARDWARE, USE OF TxC+, TxC-, RxC+, RxC- FALLS AWAY AND ONLY TWO (2) TWISTED PAIRS ARE REQUIRED. 862-01881 Issue 13 Page 41 Orion and MDR Digital Radios 5 Antenna Alignment and Software Setup This chapter describes the procedure for software setup and antenna alignment. The setup is done with a laptop / PC running the supplied NMS Graphical User Interface (GUI) software. See chapter 6 for details on using the NMS / GUI. 5.1 Installation Equipment Required The following tools and instruments are required for software setup and aligning the antenna: 5.2 • RSSI test cable • Voltmeter • Wrench / spanner (see appropriate details in installation chapter depending on the antenna being used) • PC with NMS software and supplied serial data cable. • Binoculars (optional) used for locating the far end site. This will assist in the antenna alignment operation. • GPS or Standard Compass (optional) used for locating the far end site. This will assist in the antenna alignment operation. • Bit Error Rate Tester and connecting leads. Information Required You should know: • the proposed frequency channel plan for each station. • the expected receive level based on the chosen system configuration and a path loss analysis. B.1 Antenna Alignment 5.2.1 Introduction The RFU should be installed on both sites before alignment starts. Perform the following steps at both stations: 1. Switch the Digital Indoor Unit power ON. 2. Install and run the NMS Software application. 3. Configure the radio channel plan as required. 4. Set the transmitted power to maximum. 5. Perform a RF loopback test at each site before starting the alignment procedure. 5.2.2 Alignment Procedure 1. 2. 3. 4. Locate the far site and point the antenna to the antenna at the far site, as accurately as possible using binoculars or a compass. Connect the multimeter to the RSSI connector on the RFU using the supplied RSSI test cable and set the multimeter to measure volts. Check the RSSI level and refer to the figure below for received power level. Align the antenna until the maximum RSSI is attained. 862-01881 Issue 13 Page 42 Orion and MDR Digital Radios 5. 6. 7. Secure the antenna. Measure the RSSI level and record the value (see section 5.6). Compare with the value with that calculated for the link i.e. using the path loss calculation done when planning the link. Typical Version 2 MDR OU RSSI Voltage vs Received Signal Power (5.8GHz) Outdoor Unit RSSI Voltage 1.4 1.2 0.8 0.6 0.4 -80 -75 -70 -65 -60 -55 -50 -45 -40 -35 -30 Received Signal Power [dBm] Figure 12. Typical Version 2 MDR5800 and Orion5810i RFU RSSI Voltage as a function of RF input power level -80 dBm Average 0.436 ± 0.029 V : MIB RSSI 95 ± 1 dBm (see comment below) -30 dBm Average 1.333 ± 0.047 V : MIB RSSI 54 ± 2 dBm (see comment below) The front panel RF Link LED, the Received Signal Strength Indicators (RSSI : on NMS, via SNMP or as an Electrical signal on the RF Unit), Carrier-detect (NMS, SNMP) and Frame Lock (NMS, SNMP) indicators are available to assist with link installation and alignment. NOTE 1 The MIB lists a value representative of the received signal level in [-dBm]. This value corresponds to the signal power measured in a 200 kHz BW centred at the receive frequency of the radio. When not in spectrum analyser mode, the Orion RFU translates the measured signal power to a value corresponding to the wanted signal power in the receiver bandwidth. NOTE 2 For the MDR and Orion10i RFUs, the RSSI values displayed in the MIB are representative of the signal level measured over a 200kHz BW. Add ~20dB to the MIB value for a wanted spread spectrum signal. The NMS / GUI will do this adjustment automatically and will therefore always display the correct RSSI value. NOTE 3 Due to the technique used to calculate the RSSI level of a wanted signal, the measured RSSI level can differ from the actual value with up to ±3 dB. 862-01881 Issue 13 Page 43 Orion and MDR Digital Radios Outdoor Unit RSSI Voltage Typical MDR2400 OU RSSI Voltage vs Received Signal Power 1.8 1.6 1.4 1.2 0.8 0.6 -100 -95 -90 -85 -80 -75 -70 -65 -60 -55 -50 -45 -40 Received Signal Power [dBm] Figure 13. Typical MDR2400 and Orion2410i RFU RSSI Voltage as a function of RF input power level (See comment above.) Typical Orion OU RSSI Voltage vs Received Signal Power Outdoor Unit RSSI Voltage 1.8 1.6 1.4 1.2 0.8 0.6 -100 -95 -90 -85 -80 -75 -70 -65 -60 -55 -50 -45 -40 -35 -30 Received Signal Power [dBm] Figure 14. Typical Orion 5850 RFU RSSI Voltage as a function of RF input power level (note the different bandwidths) 5.2.3 Set Transmitted Power Level It is good practice to match received power levels by adjusting transmitted powers if co-located systems are being installed. This is important to avoid interference between co-located systems. An attenuator can be fitted between the RF Unit and the antenna if the power level cannot be sufficiently reduced. The dBm output at the RFU N-type connector (socket) levels are set via the NMS or using a SNMP Management application. 862-01881 Issue 13 Page 44 Orion and MDR Digital Radios 5.3 Software Setup Refer to chapter 6, for setting up the following: 5.4 • Payload interface. • Service Channel (Wayside) serial port. • Auxiliary in/out port. • General link parameters. Functional Test After completing the physical installation of the Digital Indoor Units, antennas, RF Units and the interconnection cables, you need to commission the system. This procedure describes how to set up the minimum requirements for successful MDR / Orion system operation. 5.4.1 Link Bit Error Rate Performance Test To start : when the link is setup correctly, the RF Link LEDs on both DIUs on both sides of the RF link should be GREEN. When the link has been setup and is running error-free: 1. Clear the Digital Indoor Unit Log using Reset Button Position ‘2’ 2. Clear the Digital Indoor Unit Errors using Reset Button Position ‘1’ Perform a link bit error rate performance test as follows: • Connect a bit error rate tester to the payload interface of the link. • Run data over the link for a period of 24 hours. • Record the BER. • Record the LED statuses. Check the Digital Indoor Unit Packet Error Results via the NMS or via SNMP access to the Digital Indoor Unit MIB – for the NMS, right-click on the antennas in the NMS for either side of the link and select the “Diagnostic/Error Monitor” option. Record the results by saving the data to a file. For SNMP access, use a MIB Browser and check the mdrmteRFLinkPerf and mdrmteG826 Performance groups. Record all results on a test record. See MDR / Orion Test Record, section 5.6 for an example. 862-01881 Issue 13 Page 45 Orion and MDR Digital Radios 5.5 MDR / Orion Installation Record Parameter Unit Site A Site B Site Name Antenna Type RF cable length Meters Lightening protection unit Yes/No Interconnecting cable length Meters RF Unit serial number Digital Indoor Unit serial number RF Unit earthed Yes/No Digital Indoor Unit earthed Yes/No Power Supply Volts DC/AC Date Name Signature Performed by Approved by 862-01881 Issue 13 Page 46 Orion and MDR Digital Radios 5.6 MDR / Orion Test Record Parameter Unit Frequency channel plan: Transmit Receive NOTE 1 : C is NOT used for the MDR2400. NOTE 2 : FCC requirements (U.S. only), page 2. Transmitter output power (NOTE 2) Receiver input level (ON) Site A Site B A/B/C/D A/B/C/D If D – List Transmit and Receive Frequencies [MHz] dBm Volts Receiver input level (ON) dBm Receiver input level (OFF) Volts Receiver input level (OFF) dBm Calculated input level dBm Fade margin dB Frame Lock indicator Colour Fixed attenuator DB BER-test Hours BER Alarm Indicators Clear (Yes/No) Date Name Signature Performed by Approved by 862-01881 Issue 13 Page 47 Orion and MDR Digital Radios 6 NMS Software 6.1 Scope This section provides minimal information required to install the Orion NMS. A detailed HTML-based help document can be found on the NMS installation CD supplied with new radios. 6.2 Introduction The purpose of the Network Management System, hereafter called the NMS, is to allow you to configure, manage or interrogate the following primary functional elements of a Digital Radio Link: • Digital Indoor Unit • RF Unit A Digital Radio Link consists of two Indoor-RF Unit stations connected through a radio link. The Orion NMS is designed to auto-detect the radio type it is connected to and can support the following radio types: • Orion XX • MDR XXXX Since the firmware and software for the MDR XXXX and the Orion XX10i RFUs are exactly the same, the NMS has no means to detect the difference between these units. The NMS will therefore always display the radio type as MDR XXXX. The NMS is a PC-based software package that provides you with a graphical interface that is used to perform on-site element management of a digital radio system. It allows you to configure, manage and interrogate the system by selecting various menus and options. The hardware as well as the software constituting the NMS is collectively called the NMS Terminal. The NMS Terminal is the principal system support equipment associated with the radio for system installation and commissioning. The NMS connects to a designated NMS Terminal port (labelled Element Manager) on the front panel of the Digital Indoor Unit, by means of a serial data interface (this cable is supplied in the DIU box). It can also connect to any number of Digital Indoor Units interconnected through an IP network. The NMS communicates with SNMP agent software that is contained in each Digital Indoor Unit. The NMS communicates with the agent’s software: the software enables a unit to interpret MIB (Management Information Base) commands via SNMP (Simple Network Management Protocol). 862-01881 Issue 13 Page 48 Orion and MDR Digital Radios NOTE The NMS application supplied with older MDR radios have been replaced with the Java-based Orion NMS. The older NMS does not support the Orion series radios and it is highly recommended to replace this NMS with the Orion NMS. 6.3 System requirements The following PC system requirements apply for the Orion NMS: 6.4 • P III 450 MHz or higher CPU • 128 MB RAM • 20 MB Free Hard disk space • CD-ROM Drive • Win 98, 2000, NT or XP Operating System (Linux optional) Installing the NMS The NMS have been developed on the Java platform from Sun Micro Systems. This requires the installation of a Java Runtime Environment (JRE) on the PC from where the NMS will be used. The installation files for the NMS and the JRE are provided on the installation CD that is shipped with each radio. The supplied installation files allows the NMS to be set up on any WIN32 system (Windows 98, NT, 2000, XP). If required, a special installation can also be provided which would allow the NMS to be installed on a system using a Linux operating system. 6.4.1 JRE Installation Complete the following steps to set up the required JRE on the required PC: 6.4.2 • Browse to the //OrionNMS/JRE folder in the root of the installation CD • Execute the j2re-1_3_1_02-win.exe installation application • Follow the user prompts in the JRE installation application to set up the JRE in the preferred folder on the PC NMS Installation After installing the JRE on the PC, complete the following steps to install the NMS on the PC: • If a previous version of the Orion NMS have been installed on the target PC, first uninstall the older version • Browse to the //OrionNMS/Setup folder in the root of the installation CD • Execute the Plessey_OrionNMS_vXpXX.exe installation application • Follow the user prompts in the NMS installation application to set up the NMS in the preferred folder on the PC The NMS should now be installed on the target PC and should be available for selection through the Start Programs menu option. 862-01881 Issue 13 Page 49 Orion and MDR Digital Radios 6.4.3 NMS Un-Installation Select the Uninstall menu item in the Orion NMS menu group from the Start Programs menu to uninstall the NMS form the PC. This action removes all installed files, menu items and register entries from the PC. 6.5 Help documentation The HTML based help documents for the Orion NMS application is available on the installation CD at the following path: //OrionNMS/help/Orion NMS Help.htm. The help document can be accessed by opening it with an Internet browser of your choice. The help documents can also be opened from the Windows Start Menu folder created for the Orion NMS or through the Help|Contents menu in the Orion NMS application. 862-01881 Issue 13 Page 50 Orion and MDR Digital Radios 7 Maintenance Information 1. The user is advised to refer to the Technical Data section (paragraph 8.5.10) for details on DIU/RFU interconnection cables (customer-furnished). 2. The “Ordering Information” paragraph in the Technical Data section (paragraph 8.6) provides details on part numbers for items that can be ordered. 3. Paragraph 4 of this manual lists customer furnished equipment that should be used for installing the MDR / Orion product. 4. There are two options to control the MDR / Orion products via SNMP. a. One uses any open-standard-compliant SNMP Management package (HP OpenView, SNMPc etc): in this case, one has access to the full compliment of the product's MIB elements. b. The NMS application package supplied with the product accesses a subset of the MIB. It has a graphical user interface carefully designed to assist installation and maintenance staff. 862-01881 Issue 13 Page 51 Orion and MDR Digital Radios 8 Technical Data 8.1 8.1.1 Environmental Requirements Outdoor Equipment This specification applies to the outdoor type RFUs only. 8.1.2 Operating temperature: -30°C to +60°C Relative humidity: 8-100% Atmospheric pressure: 0.7 to 1.06 kPa Lightning protection ITU-T K.20 Indoor Equipment This specification applies to all indoor mounted units. 8.2 8.3 8.4 Operating temperature: 0°C to +50°C Relative humidity: 5-90% Lightning protection: ITU-T K.20 Mechanical Information for Outdoor Equipment Dimensions (HxWxD): 335mm x 231mm x 124mm Weight: ~ 5.9 Kg Mechanical Information for Indoor Equipment Dimensions (HxWxD): 45mm x 480 mm x 265mm Mounting: 19” Rack, 1U high or Table top Weight: ~ 2.9 Kg Power Supply Requirements DC power supply: 21 to 56 VDC (58 VDC when indicated as such) DC power supply grounding: Positively or negatively grounded Power consumption (MDR2400/5800/ Orion2410i/Orion5810i) 35 W typical, 45 W maximum. Power consumption (Orion 5825): 35 W typical, 45 W maximum – standard power 42 W typical, 52 W maximum – high power 862-01881 Issue 13 Page 52 Orion and MDR Digital Radios 8.5 8.5.1 Electrical Performance General Characteristics MDR2400-SR and Orion2410-SRi Frequency Range: 2400 to 2483.5 MHz Payload Data Capacity: T1 (1.544 Mbps/s) / E1 (2.048 Mbps) 2T1 / 2E1 4T1 / 4E1 RF Channel Bandwidth: 17 MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: CCK Processing Gain: 11 dB Frequency Channel Plan A: 2410 and 2460 MHz Frequency Channel Plan B: 2426 and 2476 MHz Transmission Delay: 600 us maximum for radios only (one-way) MDR5800-SR and Orion5810-SRi Frequency Range: 5731 to 5844 MHz Payload Data Capacity: T1 (1.544 Mbps/s) / E1 (2.048 Mbps) 2T1 / 2E1 4T1 / 4E1 RF Channel Bandwidth: 17 MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: CCK Processing Gain: 11 dB Frequency Channel Plan A: 5735 and 5804 MHz Frequency Channel Plan B: 5753 and 5822 MHz Frequency Channel Plan C: 5771 and 5840 MHz Transmission Delay: 600 us maximum for radios only (one-way) 862-01881 Issue 13 Page 53 Orion and MDR Digital Radios Orion 5825-SR Frequency Range: Payload Data Capacity: 5731 to 5844 MHz • 1 – 4T1 (1.544 Mbps/s) / 1 - 4E1 (2.048 Mbps) (2.6MHz BW) • 1 - 8T1 (1.544 Mbps/s) / 1 - 8E1 (2.048 Mbps) (5.4MHz, 8.0MHz BW) RF Channel Bandwidth: (Selectable) 2.6MHz 5.4MHz 8.0MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: 16-QAM Frequency Channel Plan A: 5731 and 5801 MHz (2.6MHz BW) 5732 and 5802 MHz (5.4MHz BW) 5734 and 5804 MHz (8.0MHz BW) Frequency Channel Plan B: 5752 and 5822 MHz (all bandwidths) Frequency Channel Plan C: 5774 and 5844 MHz (2.6MHz BW) 5773 and 5843 MHz (5.4MHz BW) 5771 and 5841 MHz (8.0MHz BW) Transmission Delay: 600 us maximum for radios only (one-way) Orion 2425-SR Frequency Range: Payload Data Capacity: 2405 to 2469 MHz • 1 - 4T1 (1.544 Mbps/s) / 1 - 4E1 (2.048 Mbps) (2.6MHz BW) • 1 - 8T1 (1.544 Mbps/s) / 1 - 8E1 (2.048 Mbps) (5.4MHz, 8.0MHz BW) RF Channel Bandwidth: (Selectable) 2.6MHz 5.4MHz 8.0MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: 16-QAM Frequency Channel Plan A: 2405 and 2444 MHz (2.6MHz BW) 2406 and 2445 MHz (5.4MHz BW) 2408 and 2447 MHz (8.0MHz BW) Frequency Channel Plan B: 2417 and 2456 MHz (all bandwidths) Frequency Channel Plan C: 2429 and 2469 MHz (2.6MHz BW) 2428 and 2468 MHz (5.4MHz BW) 2426 and 2466 MHz (8.0MHz BW) 862-01881 Issue 13 Page 54 Orion and MDR Digital Radios Transmission Delay: 600 us maximum for radios only (one-way) Orion 5850-SR Frequency Range: Payload Data Capacity: 5731 to 5844 MHz • Ethernet Only (Max 46 Mb/s bidirectional) • Optional through interface card: 1 - 16T1/E1 (1.544 Mbps/s) / (2.048 Mbps) RF Channel Bandwidth: (Selectable) 2.6MHz 5.4MHz 8.0MHz 14MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: 16-QAM / 32-QAM Frequency Channel Plan A: 5731 and 5801 MHz (2.6MHz BW) 5732 and 5802 MHz (5.4MHz BW) 5734 and 5804 MHz (8.0MHz BW) 5736 and 5806 MHz (14.0MHz BW) Frequency Channel Plan B: 5752 and 5822 MHz (all bandwidths) Frequency Channel Plan C: 5774 and 5844 MHz (2.6MHz BW) 5773 and 5843 MHz (5.4MHz BW) 5771 and 5841 MHz (8.0MHz BW) 5769 and 5839 MHz (14.0MHz BW) Transmission Delay: 600 us maximum for radios only (one-way) Orion 2450-SR Frequency Range: Payload Data Capacity: 2405 to 2469 MHz • Ethernet Only (Max 46 Mb/s bidirectional) • Optional through interface card: 1 - 16T1/E1 (1.544 Mbps/s) / (2.048 Mbps) RF Channel Bandwidth: (Selectable) 2.6MHz 5.4MHz 8.0MHz 14.0 MHz Go/Return spacing: Can be adjusted as fixed go-return spacing. NOT mandatory in the ISM licence-free bands. Modulation: 16-QAM / 32-QAM Frequency Channel Plan A: 2405 and 2444 MHz (2.6MHz BW) 2406 and 2445 MHz (5.4MHz BW) 862-01881 Issue 13 Page 55 Orion and MDR Digital Radios 2408 and 2447 MHz (8.0MHz BW) 2410 and 2451 MHz (14.0MHz BW) Frequency Channel Plan B: 2417 and 2457 MHz (all bandwidths except 14 MHz) Frequency Channel Plan C: 2429 and 2469 MHz (2.6MHz BW) 2428 and 2468 MHz (5.4MHz BW) 2426 and 2466 MHz (8.0MHz BW) 2424 and 2463 MHz (14.0MHz BW) Transmission Delay: 600 us maximum for radios only (one-way) 862-01881 Issue 13 Page 56 Orion and MDR Digital Radios 8.5.2 Transceiver Characteristics 8.5.2.1 Frequency Band: MDR2400 and Orion2410i Lowband RF Units Transmit band: 2410 – 2426 MHz (Centre frequency) Receive band: 2458 – 2474 MHz (Centre frequency) 8.5.2.2 Frequency Band: MDR2400 and Orion2410i Highband RF Units Transmit band: 2458 – 2474 MHz (Centre frequency) Receive band: 2410 – 2426 MHz (Centre frequency) 8.5.2.3 Frequency Band: MDR5800 and Orion5810i Lowband RF Units Transmit band: 5725 – 5787 MHz (Band edge) Receive band: 5787 – 5850 MHz (Band edge) 8.5.2.4 Frequency Band: MDR5800 and Orion5810i Highband RF Units Transmit band: 5787 – 5850 MHz (Band edge) Receive band: 5725 – 5787 MHz (Band edge) 8.5.2.5 Frequency Band: Orion 5850 Lowband RF Units Transmit band: 5731 – 5774 MHz (Center frequency) Receive band: 5801 – 5844 MHz (Center frequency) 8.5.2.6 Frequency Band: Orion 5850 Highband RF Units Transmit band: 5801 – 5844 MHz (Center frequency) Receive band: 5731 – 5774 MHz (Center frequency) 8.5.2.7 Frequency Band: Orion 2450 Lowband RF Units Transmit band: 2405 – 2429 MHz (Center frequency) Receive band: 2444 – 2469 MHz (Center frequency) 8.5.2.8 Frequency Band: Orion 2450 Highband RF Units Transmit band: 2444 – 2469 MHz (Center frequency) Receive band: 2405 – 2429 MHz (Center frequency) 862-01881 Issue 13 Page 57 Orion and MDR Digital Radios 8.5.3 8.5.4 RF Interface Transmitted Power +2 to+24 dBm – MDR2400, MDR5800, Orion2410i +2 to+25 dBm – Orion5810i +2 to +24 dBm – Orion 5850 high output power, software adjustable (incl. mute) Receiver Sensitivity: Up to 4T1/4E1 : -6 -88dBm for BER = 10 (MDR2400) -6 -86dBm for BER = 10 (MDR5800) Up to 16T1/E1 : Orion 5850, 16/32 QAM -6 -88dBm for BER = 10 (2.6 MHz BW) -6 -85dBm for BER = 10 (5.4 MHz BW) -6 -83dBm for BER = 10 (8 MHz BW) -6 -78dBm for BER = 10 (14 MHz BW) Maximum Receive Level: -30dBm Payload Data Interfaces 8.5.4.1 1, 2, 4 or 8 (i.e. nE1) Interface (MDR – Orion 10/25) Data Rate: Full duplex E1 (2.048Mbit/s), 2E1, 4E1 or 8E1 Digital Interface: ITU-T G.703 Connectors: Balanced 110 ohm on DB25 Balanced 110 ohm on RJ45 (Orion 10/25 DIU only) Unbalanced 75 ohm on BNC’s (Available on one of the MDR DIU variants) Line code: HDB3 or AMI selectable, refer to Section 2.3.1 Jitter and Wander: ITU-T G.823 8.5.4.2 1, 2, 4 or 8 (i.e. nT1) Interface (MDR – Orion 10/25) Data Rate: Full duplex T1 (1.544Mbit/s), 2T1, 4T1 or 8T1 Digital Interface: DSX-1, G.703 compliant Connectors: Balanced 110 ohm on DB25 Balanced 110 ohm on RJ45 (Orion 10/25 DIU only) Unbalanced 75 ohm on BNC’s (Available on one of the MDR DIU variants) Line code: AMI or B8ZS selectable, refer to Section 2.3.1 Jitter and Wander: ITU-T G.823 862-01881 Issue 13 Page 58 Orion and MDR Digital Radios 8.5.4.3 1-16 (i.e. nT1) Interface Card (Available on Orion50 as optional I/F card) Data Rate: Full duplex T1 (1.544Mbit/s) up to 16T1 Digital Interface: DSX-1, G.703 compliant Connectors: Balanced on DB25, Termination impedance selectable per tributary channel through software (75, 100, 110, 120 ohn) Line code: AMI or B8ZS selectable per tributary channel through software Jitter and Wander: ITU-T G.823 8.5.4.4 1-16 (i.e. nE1) Interface Card (Available on Orion50 as optional I/F card) 8.5.5 Data Rate: Full duplex E1 (2.048Mbit/s) up to 16E1 Digital Interface: ITU-T G.703 Connectors: Balanced on DB25, Termination impedance selectable per tributary channel through software (75, 100, 110, 120 ohn) Line code: AMI or B8ZS selectable per tributary channel through software Jitter and Wander: ITU-T G.823 Ethernet Traffic Interface All except Orion 50 DIU: Data Rate: < 8 Mbps Half / full duplex software selectable (Refer to Chapter G, page 131) Digital Interface: 10 BaseT, Half / full duplex, DTE Connector: RJ45 Orion 50 DIU: 8.5.6 Data Rate: < 46 Mbps Half / full duplex software selectable limited by RF data capacity Digital Interface: 10/100 BaseT, Half / full duplex, DTE Connector: RJ45 Auxiliary Input Interface (CONTACT CLOSURE) Number of Inputs: Maximum voltage: 12V Logical zero: Short from input to return pin 862-01881 Issue 13 Page 59 Orion and MDR Digital Radios Logical one: 8.5.7 Open input to return pin Auxiliary Output Interface Number of outputs: States: Normally-open and normally-closed Contact rating: DC: 220 V, 1 A, 60 W AC: 250 V, 1 A, 125 VA 8.5.8 8.5.9 Wayside channel interface Interface standard: RS232, DCE Handshaking: None, Hardware Port rate: 115,200 bps Element Manager Port Interface Interface standard: RS232, DTE Handshaking: Hardware Data rate: 115,200 bps 8.5.10 Indoor/RF Unit Interface The physical interface between the Indoor and RF Unit is IEEE802.3 Ethernet. As such, the same considerations that apply between standard routers/switches/hubs and PC LAN cards should be adhered to when selecting lengths of cables between the RFU and the DIU. Cable lengths of up to 120 meters have been tested in a laboratory environment. The following table lists information to assist the user to select cables to be used between the Indoor and RF Units. Interconnecting cable Data South Africa STP (FTP) 4 Pairs Solid Cat 5, PVC FR UV protected Polifin H2/J263/904 Outer Black. Outer diameter of cable : 7.3mm ± 0.5mm. (this is an “upjacketed” STP 4 Pair cable). This is a standard FTP Cat 5 cable that is ‘upjacketed’ with suitable plastic for FR/UV (Flame retardant/Ultra Violet) protection. Other cables: 1. 2. 3. 4. Superior Essex BBDN CAT 5 cable P/N 04-0010-34 (7.8mm) Superior Essex CAT 5 P/N 18-241-31 18-241-11 (5.1mm) General Cable CAT 5 P/N 2137113 2137114 (5.6mm) Belden CAT 5 P/N BC1002 (6.0mm) 862-01881 Issue 13 Page 60 Orion and MDR Digital Radios Option 1 is the preferred choice. For the cables that have diameters less the required OD, one can use one or two pieces of heatshrink on the cable where it passes through the gasket. Interconnecting cable Power South Africa Power 1.5mm sq stranded PVC Insulated, PVC FR UV protected Polifin H2/J263/904 Outer Black 300/500V Temp -20°C to +85°C. Cable outer diameter: between 7.4mm and 9mm i.e. 8.2mm ± 0.8mm. Other cables: Superior Essex type SJOOW flexible cable P/N 441821* (7.4mm) Carol Cable (General Cable) SJOW/SJO P/N 02001 18 gauge 2 conductor (7.8mm) 862-01881 Issue 13 Page 61 Orion and MDR Digital Radios 8.6 Ordering Information MDR 2400 SR Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-03994-01-H1-PT 651-03994-01-L1-PT 651-03994-01-H2-PT 651-03994-01-L2-PT 651-03994-01-H4-PT 651-03994-01-L4-PT 651-04106-01-H1-PT 651-04106-01-L1-PT 651-04106-01-H2-PT 651-04106-01-L2-PT 651-04106-01-H4-PT 651-04106-01-L4-PT MDR 2400 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced Interface - DB25 (specify - E1 or T1, Bridge or Router) MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 Unbalanced Interface - BNC (specify - E1 or T1, Bridge or Router) MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 MDR 2400 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 MDR 2400 SR operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for MDR 2400 SR Ordering Code Description 862-01881 Issue 13 Page 62 Orion and MDR Digital Radios 651-03994-01-S1-PT 651-03994-01-S2-PT 651-03994-01-S4-PT 651-04106-01-S1-PT 651-04106-01-S2-PT 651-04106-01-S4-PT MDR 2400 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced Interface - DB25 (specify - E1 or T1, Bridge or Router) MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Unbalanced Interface - BNC (specify - E1 or T1, Bridge or Router) MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 MDR 2400 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Ordering Code 651-03905-01L-PT 651-03905-01H-PT Description MDR 2400 SR Low Band Outdoor RF Unit - Spare Part MDR 2400 SR High Band Outdoor RF Unit - Spare Part 651-04104-02-1-PT 651-04104-02-2-PT 651-04104-02-4-PT Balanced Interface - DB25 (specify - E1 or T1) MDR 2400 SR Digital Unit 1xE1/T1 - Spare Part MDR 2400 SR Digital Unit 2xE1/T1 - Spare Part MDR 2400 SR Digital Unit 4xE1/T1 - Spare Part 651-04105-02-1-PT 651-04105-02-2-PT 651-04105-02-4-PT Unbalanced Interface - BNC (specify - E1 or T1) MDR 2400 SR Digital Unit 1xE1/T1 - Spare Part MDR 2400 SR Digital Unit 2xE1/T1 - Spare Part MDR 2400 SR Digital Unit 4xE1/T1 - Spare Part The MDR 2400 SR uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Outdoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Outdoor RF Unit. 862-01881 Issue 13 Page 63 Orion and MDR Digital Radios Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. MDR 5800 SR Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-03853-02-H1-PT 651-03853-02-L1-PT 651-03853-02-H2-PT 651-03853-02-L2-PT 651-03853-02-H4-PT 651-03853-02-L4-PT 651-04055-02-H1-PT 651-04055-02-L1-PT 651-04055-02-H2-PT 651-04055-02-L2-PT 651-04055-02-H4-PT 651-04055-02-L4-PT MDR 5800 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced Interface - DB25 (specify - E1 or T1, Bridge or Router) MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 Unbalanced Interface - BNC (specify - E1 or T1, Bridge or Router) MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 MDR 5800 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 MDR 5800 SR operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for MDR 5800 SR Ordering Code Description 862-01881 Issue 13 Page 64 Orion and MDR Digital Radios 651-03853-02-S1-PT 651-03853-02-S2-PT 651-03853-02-S4-PT 651-04055-02-S1-PT 651-04055-02-S2-PT 651-04055-02-S4-PT MDR 5800 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced Interface - DB25 (specify - E1 or T1, Bridge or Router) MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Unbalanced Interface - BNC (specify - E1 or T1, Bridge or Router) MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 MDR 5800 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Ordering Code 651-03806-02L-PT 651-03806-02H-PT Description MDR 5800 SR Low Band Outdoor RF Unit - Spare Part MDR 5800 SR High Band Outdoor RF Unit - Spare Part 651-04104-02-1-PT 651-04104-02-2-PT 651-04104-02-4-PT Balanced Interface - DB25 (specify - E1 or T1) MDR 5800 SR Digital Unit 1xE1/T1 - Spare Part MDR 5800 SR Digital Unit 2xE1/T1 - Spare Part MDR 5800 SR Digital Unit 4xE1/T1 - Spare Part 651-04105-02-1-PT 651-04105-02-2-PT 651-04105-02-4-PT Unbalanced Interface - BNC (specify - E1 or T1) MDR 5800 SR Digital Unit 1xE1/T1 - Spare Part MDR 5800 SR Digital Unit 2xE1/T1 - Spare Part MDR 5800 SR Digital Unit 4xE1/T1 - Spare Part The MDR 5800 SR uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Outdoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Outdoor RF Unit. Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. 862-01881 Issue 13 Page 65 Orion and MDR Digital Radios Orion 2410 SR Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04373-01-H1-PT 651-04373-01-L1-PT 651-04373-01-H2-PT 651-04373-01-L2-PT 651-04373-01-H4-PT 651-04373-01-L4-PT Orion 2410 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 2410 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 Orion 2410 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 Orion 2410 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 Orion 2410 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 Orion 2410 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 Orion 2410 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 Orion 2410 SR operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2410 SR Ordering Code Description 651-04373-01-S1-PT 651-04373-01-S2-PT 651-04373-01-S4-PT Ordering Code 651-03905-01L-PT 651-03905-01H-PT 862-01881 Issue 13 Orion 2410 SR Sp-Pkg: Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 2410 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 Orion 2410 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 Orion 2410 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Description Orion 2410 SR Low Band Outdoor RF Unit - Spare Part Orion 2410 SR High Band Outdoor RF Unit - Spare Part Page 66 Orion and MDR Digital Radios 651-04316-01-01-P 651-04316-01-02-P 651-04316-01-04-P Balanced/Unbalanced Interface - DB25 (specify - E1 or T1) Orion 10 Digital Unit 1xE1/T1 - Spare Part Orion 10 Digital Unit 2xE1/T1 - Spare Part Orion 10 Digital Unit 4xE1/T1 - Spare Part The Orion 2410 SR uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Outdoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Outdoor RF Unit. Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. Orion 2410 SRi Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04317-01-H1-PT 651-04317-01-L1-PT 651-04317-01-H2-PT 651-04317-01-L2-PT 651-04317-01-H4-PT 651-04317-01-L4-PT Orion 2410 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 2410 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 1E1 /1T1 Orion 2410 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 1E1 /1T1 Orion 2410 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 2E1 /2T1 Orion 2410 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 2E1 /2T1 Orion 2410 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 4E1 /4T1 Orion 2410 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 4E1 /4T1 Orion 2410 SRi operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2410 SRi Ordering Code Description 862-01881 Issue 13 Page 67 Orion and MDR Digital Radios 651-04317-01-S1-PT 651-04317-01-S2-PT 651-04317-01-S4-PT Orion 2410 SRi Sp-Pkg: Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 2410 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 1E1 /1T1 Orion 2410 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 2E1 /2T1 Orion 2410 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 4E1 /4T1 Ordering Code 651-04353-01L-P 651-04353-01H-P Description Orion 2410 SRi Low Band Indoor RF Unit - Spare Part Orion 2410 SRi High Band Indoor RF Unit - Spare Part 651-04316-01-01-P 651-04316-01-02-P 651-04316-01-04-P Balanced/Unbalanced Interface - DB25 (specify - E1 or T1) Orion 10 Digital Unit 1xE1/T1 - Spare Part Orion 10 Digital Unit 2xE1/T1 - Spare Part Orion 10 Digital Unit 4xE1/T1 - Spare Part The Orion 2410 SRi uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Indoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Indoor RF Unit. Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. Orion 2425 SR Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04367-01-H08-P 651-04367-01-L08-P 862-01881 Issue 13 Orion 2425 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, TypeN RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 2425 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 8E1 /8T1 Orion 2425 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 8E1 /8T1 Page 68 Orion and MDR Digital Radios Orion 2425 SR Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2425 SR Ordering Code Description 651-04367-01-S08-P Orion 2425 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 2425 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 8E1 /8T1 Ordering Code 651-04368-01L-P 651-04368-01H-P Description Orion 2450 Low Band Outdoor RF Unit - Spare Part Orion 2450 High Band Outdoor RF Unit - Spare Part 651-04313-01-08-P IDU (specify - E1 or T1) Orion 25 Digital Unit 8xE1/T1 - Spare Part Orion 2425 SRi Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description Orion 2425 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, TypeN RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface 651-04369-01-H08-P Orion 2425 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 8E1 /8T1 651-04369-01-L08-P Orion 2425 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 8E1 /8T1 Orion 2425 SRi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) 862-01881 Issue 13 Page 69 Orion and MDR Digital Radios Microwave Digital Radio System Spare Parts for Orion 2425 SRi Ordering Code Description 651-04369-01-S08-P Orion 2425 SRi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 2425 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 8E1 /8T1 Ordering Code 651-04370-01L-P 651-04370-01H-P Description Orion 2450i Low Band Indoor RF Unit - Spare Part Orion 2450i High Band Indoor RF Unit - Spare Part 651-04313-01-08-P IDU (specify - E1 or T1) Orion 25 Digital Unit 8xE1/T1 - Spare Part Orion 2450 IP Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04371-01-HE-P 651-04371-01-LE-P Orion 2450 IP Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 2450 IP Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - IP only Orion 2450 IP Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - IP only Orion 2450 IP Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2450 IP Ordering Code Description 862-01881 Issue 13 Page 70 Orion and MDR Digital Radios 651-04371-01-SE-P Orion 2450 IP Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 2450 IP Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - IP only Ordering Code 651-04368-01L-P 651-04368-01H-P Description Orion 2450 Low Band Outdoor RF Unit - Spare Part Orion 2450 High Band Outdoor RF Unit - Spare Part 651-04322-01-E-P IDU (specify - E1 or T1) Orion 50 Digital Unit IP only - Spare Part Orion 2450 IPi Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04374-01-HE-P 651-04374-01-LE-P Orion 2450 IPi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, TypeN RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 2450 IPi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - IP only Orion 2450 IPi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - IP only Orion 2450 IPi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2450 IPi Ordering Code Description 651-04374-01-SE-P 862-01881 Issue 13 Orion 2450 IPi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex Ethernet 10/100 BaseT data interface Orion 2450 IPi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - IP only Page 71 Orion and MDR Digital Radios Ordering Code 651-04370-01L-P 651-04370-01H-P Description Orion 2450i Low Band Indoor RF Unit - Spare Part Orion 2450i High Band Indoor RF Unit - Spare Part 651-04322-01-E-P IDU (specify - E1 or T1) Orion 50 Digital Unit IP only - Spare Part Orion 2450 SR Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04377-01-H16-P 651-04377-01-L16-P Orion 2450 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 2450 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 16E1 /16T1 Orion 2450 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 16E1 /16T1 Orion 2450 SR Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2450 SR Ordering Code Description 651-04377-01-S16-P Orion 2450 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 2450 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 16E1 /16T1 Ordering Code 651-04368-01L-P Description Orion 2450 Low Band Outdoor RF Unit - Spare Part 862-01881 Issue 13 Page 72 Orion and MDR Digital Radios 651-04368-01H-P Orion 2450 High Band Outdoor RF Unit - Spare Part 651-04379-01-16-P IDU (specify - E1 or T1) Orion 50 Digital Unit 16xE1/T1 - Spare Part Orion 2450 SRi Microwave Digital Radio System, 2.4GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04380-01-H16-P 651-04380-01-L16-P Orion 2450 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 2450 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 16E1 /16T1 Orion 2450 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 16E1 /16T1 Orion 2450 SRi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 2450 SRi Ordering Code Description 651-04380-01-S16-P Orion 2450 SRi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 2450 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 16E1 /16T1 Ordering Code 651-04370-01L-P 651-04370-01H-P Description Orion 2450i Low Band Indoor RF Unit - Spare Part Orion 2450i High Band Indoor RF Unit - Spare Part IDU (specify - E1 or T1) 862-01881 Issue 13 Page 73 Orion and MDR Digital Radios 651-04379-01-16-P Orion 50 Digital Unit 16xE1/T1 - Spare Part Orion 5810 SR Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04375-02-H1-PT 651-04375-02-L1-PT 651-04375-02-H2-PT 651-04375-02-L2-PT 651-04375-02-H4-PT 651-04375-02-L4-PT Orion 5810 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 5810 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 1E1 /1T1 Orion 5810 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 1E1 /1T1 Orion 5810 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 2E1 /2T1 Orion 5810 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 2E1 /2T1 Orion 5810 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 4E1 /4T1 Orion 5810 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 4E1 /4T1 Orion 5810 SR operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5810 SR Ordering Code Description 651-04375-02-S1-PT 651-04375-02-S2-PT 651-04375-02-S4-PT Ordering Code 862-01881 Issue 13 Orion 5810 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 5810 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 1E1 /1T1 Orion 5810 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 2E1 /2T1 Orion 5810 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 4E1 /4T1 Description Page 74 Orion and MDR Digital Radios 651-03806-02L-PT 651-03806-02H-PT Orion 5810 SR Low Band Outdoor RF Unit - Spare Part Orion 5810 SR High Band Outdoor RF Unit - Spare Part 651-04316-01-01-P 651-04316-01-02-P 651-04316-01-04-P Balanced/Unbalanced Interface - DB25 (specify - E1 or T1) Orion 10 Digital Unit 1xE1/T1 - Spare Part Orion 10 Digital Unit 2xE1/T1 - Spare Part Orion 10 Digital Unit 4xE1/T1 - Spare Part The Orion 5810 SR uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Outdoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Outdoor RF Unit. Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. Orion 5810 SRi Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04318-02-H1-PT 651-04318-02-L1-PT 651-04318-02-H2-PT 651-04318-02-L2-PT 651-04318-02-H4-PT 651-04318-02-L4-PT Orion 5810 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 5810 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 1E1 /1T1 Orion 5810 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 1E1 /1T1 Orion 5810 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 2E1 /2T1 Orion 5810 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 2E1 /2T1 Orion 5810 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 4E1 /4T1 Orion 5810 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 4E1 /4T1 Orion 5810 SRi operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5810 SRi Ordering Code Description 862-01881 Issue 13 Page 75 Orion and MDR Digital Radios 651-04318-02-S1-PT 651-04318-02-S2-PT 651-04318-02-S4-PT Orion 5810 SRi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 9.5Mbps link data capacity, fully scalable between 10 BaseT Ethernet and up to 4xE1(4x2Mbps) or 4xT1(4x1.5Mbps) data interface Balanced/Unbalanced Interface - DB25 (specify - E1 or T1, Bridge or Router) Orion 5810 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 1E1 /1T1 Orion 5810 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 2E1 /2T1 Orion 5810 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 4E1 /4T1 Ordering Code 651-04354-01L-PT 651-04354-01H-PT Description Orion 5810 SRi Low Band Indoor RF Unit - Spare Part Orion 5810 SRi High Band Indoor RF Unit - Spare Part 651-04316-01-01-P 651-04316-01-02-P 651-04316-01-04-P Balanced/Unbalanced Interface - DB25 (specify - E1 or T1) Orion 10 Digital Unit 1xE1/T1 - Spare Part Orion 10 Digital Unit 2xE1/T1 - Spare Part Orion 10 Digital Unit 4xE1/T1 - Spare Part The Orion 5810 SRi uses standard CAT5 Ethernet cable and RJ-45 connectors for connecting the Digital Unit to the Indoor RF Unit. A two-wire power cable is also required between the Digital Unit and the Indoor RF Unit. Note Screened Cat5 cable, and UV resistant cables are recommended for long term outdoor use. Orion 5825 SR Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04253-01-H08-P 651-04253-01-L08-P 862-01881 Issue 13 Orion 5825 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, TypeN RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 5825 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 8E1 /8T1 Orion 5825 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 8E1 /8T1 Page 76 Orion and MDR Digital Radios Orion 5825 SR Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5825 SR Ordering Code Description 651-04253-01-S08-P Orion 5825 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 5825 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 8E1 /8T1 Ordering Code 651-04254-01L-P 651-04254-01H-P Description Orion 5850 Low Band Outdoor RF Unit - Spare Part Orion 5850 High Band Outdoor RF Unit - Spare Part 651-04313-01-08-P IDU (specify - E1 or T1) Orion 25 Digital Unit 8xE1/T1 - Spare Part Orion 5825 SRi Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description Orion 5825 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, TypeN RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface 651-04342-01-H08-P Orion 5825 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 8E1 /8T1 651-04342-01-L08-P Orion 5825 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 8E1 /8T1 Orion 5825 SRi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) 862-01881 Issue 13 Page 77 Orion and MDR Digital Radios Microwave Digital Radio System Spare Parts for Orion 5825 SRi Ordering Code Description 651-04342-01-S08-P Orion 5825 SRi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 25Mbps link data capacity, 10 BaseT Ethernet and up to 8xE1(8x2Mbps) or 8xT1(8x1.5Mbps) data interface Orion 5825 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 8E1 /8T1 Ordering Code 651-04358-01L-P 651-04358-01H-P Description Orion 5850i Low Band Indoor RF Unit - Spare Part Orion 5850i High Band Indoor RF Unit - Spare Part 651-04313-01-08-P IDU (specify - E1 or T1) Orion 25 Digital Unit 8xE1/T1 - Spare Part Orion 5850 IP Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04305-01-HE-P 651-04305-01-LE-P Orion 5850 IP Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 5850 IP Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - IP only Orion 5850 IP Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - IP only Orion 5850 IP Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5850 IP Ordering Code Description 862-01881 Issue 13 Page 78 Orion and MDR Digital Radios 651-04305-01-SE-P Orion 5850 IP Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, Up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 5850 IP Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - IP only Ordering Code 651-04254-01L-P 651-04254-01H-P Description Orion 5850 Low Band Outdoor RF Unit - Spare Part Orion 5850 High Band Outdoor RF Unit - Spare Part 651-04322-01-E-P IDU (specify - E1 or T1) Orion 50 Digital Unit IP only - Spare Part Orion 5850 IPi Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04385-01-HE-P 651-04385-01-LE-P Orion 5850 IPi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, TypeN RF output, high power output for FCC and unregulated, up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 5850 IPi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - IP only Orion 5850 IPi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - IP only Orion 5850 IPi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5850 IPi Ordering Code Description 651-04385-01-SE-P 862-01881 Issue 13 Orion 5850 IPi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, up to 46 Mbps full duplex 10/100 BaseT Ethernet data interface Orion 5850 IPi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - IP only Page 79 Orion and MDR Digital Radios Ordering Code 651-04358-01L-P 651-04358-01H-P Description Orion 5850i Low Band Indoor RF Unit - Spare Part Orion 5850i High Band Indoor RF Unit - Spare Part 651-04322-01-E-P IDU (specify - E1 or T1) Orion 50 Digital Unit IP only - Spare Part Orion 5850 SR Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum Ordering Code Description 651-04387-01-H16-P 651-04387-01-L16-P Orion 5850 SR Radio: 1 Digital Unit and 1 High or Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 5850 SR Radio:1 Digital Unit and 1 High Band Outdoor RF Unit - 16E1 /16T1 Orion 5850 SR Radio:1 Digital Unit and 1 Low Band Outdoor RF Unit - 16E1 /16T1 Orion 5850 SR Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5850 SR Ordering Code Description 651-04387-01-S16-P Orion 5850 SR Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Outdoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 5850 SR Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Outdoor RF Unit - 16E1 /16T1 Ordering Code 651-04254-01L-P Description Orion 5850 Low Band Outdoor RF Unit - Spare Part 862-01881 Issue 13 Page 80 Orion and MDR Digital Radios 651-04254-01H-P Orion 5850 High Band Outdoor RF Unit - Spare Part 651-04379-01-16-P IDU (specify - E1 or T1) Orion 50 Digital Unit 16xE1/T1 only - Spare Part Orion 5850 SRi Microwave Digital Radio System, 5.8GHz ISM Frequency Band, Spread Spectrum - All indoor radio Ordering Code Description 651-04389-01-H16-P 651-04389-01-L16-P Orion 5850 SRi Radio: 1 Digital Unit and 1 High or Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 5850 SRi Radio:1 Digital Unit and 1 High Band Indoor RF Unit - 16E1 /16T1 Orion 5850 SRi Radio:1 Digital Unit and 1 Low Band Indoor RF Unit - 16E1 /16T1 Orion 5850 SRi Radio operates from 21-56VDC, optional 110-220VAC power supply available below. A complete link requires two radios, one must be High Band (HB) and the other a Low Band (LB) Microwave Digital Radio System Spare Parts for Orion 5850 SRi Ordering Code Description 651-04389-01-S16-P Orion 5850 SRi Sp-Pkg: 1 Digital Unit and 1 High and 1 Low band Indoor RF Unit, Type-N RF output, high power output for FCC and unregulated, 46Mbps link data capacity, fully scalable between 10/100 BaseT Ethernet and up to 16xE1(16x2Mbps) or 16xT1(16x1.5Mbps) data interface Orion 5850 SRi Sp-Pkg:1 Digital Unit and 1 HB and 1 LB Indoor RF Unit - 16E1 /16T1 Ordering Code 651-04358-01L-P 651-04358-01H-P Description Orion 5850i Low Band Indoor RF Unit - Spare Part Orion 5850i High Band Indoor RF Unit - Spare Part IDU (specify - E1 or T1) 862-01881 Issue 13 Page 81 Orion and MDR Digital Radios 651-04379-01-16-P 862-01881 Issue 13 Orion 50 Digital Unit 16xE1/T1 only - Spare Part Page 82 Orion and MDR Digital Radios A Appendix: Element Manager Port Point-to-Point Serial Communications Setup This appendix summarises how to set up a network connection (using PPP) between a computer and the MDR / Orion DIU’s Element Manager port. It lists how the connection can be setup and configured to allow data transfer and SNMP-based control of the MDR / Orion DIU. Note : For both NT and Win 95 or 98 machines, check that a Network Adapter is installed. The following screen capture shows the Windows help available to assist setting up a serial comms network adapter. A.1 Adding a Modem : Windows NT 1. When working with a PC running a Windows NT, add a modem using the following screen as a guideline. 862-01881 Issue 13 Page 83 Orion and MDR Digital Radios 862-01881 Issue 13 Page 84 Orion and MDR Digital Radios 862-01881 Issue 13 Page 85 Orion and MDR Digital Radios 2. Select the COM port to use – push the Next when the COM port has been selected. 862-01881 Issue 13 Page 86 Orion and MDR Digital Radios 862-01881 Issue 13 Page 87 Orion and MDR Digital Radios A.2 Adding Dial-up Networking : Windows NT A.2.1 To add dial-up networking 1. From the desktop, open the My Computer icon and double-click the Dial-up Networking icon. 2. The following windows are displayed: 862-01881 Issue 13 Page 88 Orion and MDR Digital Radios 3. Whether COM1 or COM2 is selected, setup the connection using the following screens as a guideline. This allows establishment of a PPP connection between the computer and the DIU’s Element Manager port. 862-01881 Issue 13 Page 89 Orion and MDR Digital Radios 862-01881 Issue 13 Page 90 Orion and MDR Digital Radios 862-01881 Issue 13 Page 91 Orion and MDR Digital Radios 862-01881 Issue 13 Page 92 Orion and MDR Digital Radios A.3 Adding a Modem : Windows 95/98 1. When working with a PC running a Windows 95/98, add a modem using the following screen as a guideline. 3. Use the mdrnull.inf to add a serial cable modem connection capability to the PC or laptop. 862-01881 Issue 13 Page 93 Orion and MDR Digital Radios 4. Once setup, use the following screens to set up the COM port’s parameters. 862-01881 Issue 13 Page 94 Orion and MDR Digital Radios A.4 Adding Dial-up Networking : Windows 95/98 1. After adding the modem, set up the connection properties using the following screens as a guideline. This will allow establishment of a PPP connection between the computer and the DIU’s Element Manager port. A Null_Modem connection option as shown below will be created. If one doesn’t exist, double click on the “Make New Connection” icon. 862-01881 Issue 13 Page 95 Orion and MDR Digital Radios 862-01881 Issue 13 Page 96 Orion and MDR Digital Radios A.5 Adding Dial-up Networking : Windows 2000 / Windows XP A.5.1 To add dial-up networking The installation procedure documented here is based on the procedure that should be followed for Windows 2000. Some of the configuration windows for Windows XP may look slightly different, and may appear in a different order, but the basic procedure are the same as for Windows 2000 and are therefore not repeated in an attempt to reduce the size of this user manual. 1. Select the Make New Connection menu item. Win2000 & Win-XP 862-01881 Issue 13 Page 97 Orion and MDR Digital Radios 2. Select the Connect directly to another computer and press the Next button. Win2000 Win-XP 862-01881 Issue 13 Page 98 Orion and MDR Digital Radios 3. Set the dialup connection to connect as Guest and press the Next button. Win2000 & Win-XP 4. Select the COM port you intend to use to connect to the radio from the Select Device dropdown box and press the Next button. In Windows XP, this window is preceded by Step 6 below. Win2000 & Win-XP 862-01881 Issue 13 Page 99 Orion and MDR Digital Radios 5. Select the users that must be able to use this dialup connection and press the Next button. Win2000 & Win-XP 862-01881 Issue 13 Page 100 Orion and MDR Digital Radios 6. Enter the name of this dialup connection and press the Finish button. This name may be any name of your choice. The connection is now installed, but its properties must still be configured. This window is displayed earlier in Windows XP. Win2000 & Win-XP 7. Finish installing the connection (Windows XP only) Win-XP 862-01881 Issue 13 Page 101 Orion and MDR Digital Radios 8. Browse to the newly added connection under the Network and Dial-Up connections menu item of Windows, and right-click on the connection with your mouse. Select the Properties item from the pop-up menu to bring up the properties window below. Now click on the Configure button below the Select a Device combo box in the General properties tab window to bring up the Modem Configuration box below. Make sure that all the settings on your PC are the same is in this window (Maximum speed: 115200 bps & hardware flow control enabled). Now press the OK button. Win2000 & Win-XP 9. In the Options properties box below, select Redial if line is dropped and press the OK button. Win2000 & Win-XP 862-01881 Issue 13 Page 102 Orion and MDR Digital Radios 10. Browse to the newly added connection under the Network and Dial-Up connections menu item of Windows, and left-click on the connection with your mouse. This will bring up the connection window below. The values of the Username and Password fields does not matter, press Connect to dial into the radio once the dialup cable has been plugged into the Digital Indoor Unit and the PC. Win2000 & Win-XP 862-01881 Issue 13 Page 103 Orion and MDR Digital Radios B Appendix: MANAGEMENT OF THE MDR2400-SR MDR5800-SR and the Orion 5825-sr All management of the MDR and Orion products are implemented using SNMP (Simple Network Management Protocol), an open standard. The products can be managed by: 1. Standard SNMP managers such as HP OpenView or SNMPc i.e. there is Open Network Management compatibility. 2. For rapid product installation, the NMS GUI Application (hereafter referred to as the NMS-GA) provides extensive management functions on site and, via the microwave radio link, can be used to access the MDR / Orion station on the opposite side of the link. The NMS-GA is a software application that runs on a PC workstation such as a laptop or notebook computer that is connected to an MDR / Orion Digital Indoor Unit serial port (DB9 DTE) or an Ethernet connection (10BaseT DTE), both accessed via the DIU front-panel. B.1 SNMP and the MDR / Orion Use of SNMP within the product allows remote: configuration, monitoring of performance, notification of alarms and firmware upgrades via an IP-network. Within an IP network supporting routing of IP data, the radios can be supported from any remote location. The product can be accessed via the Internet if the necessary gateways are provided. A GSM/PCS modem dial-up capability provides another remote management option. The Digital Indoor Units have built-in SNMP agents and an extensive MIB (Management Information Base). The MDR /Orion product uses SNMP V1 (RFC1155, 1157). The user has access to an Enterprise MIB (obtainable though customer services) and MIB II (RFC 1213). Access to the MIB via the DIU SNMP agent is via Ethernet (10BaseT interface on the product's front panel) or PPP (RFC 1661) via the product's serial channel Element Manager port. The use of SNMP provides flexibility for operators with central equipment monitoring. It provides management access to radio configuration (all data interfaces), interface status and statistics, fault and maintenance information. SNMP security (if enabled) is ensured by using a login and password to give the user "administrator" or "standard user" rights. The "standard user rights" option limits the ability to SET MIB variables. NOTE Secure SNMP is not longer supported. The product has threshold-based alarm generation (there is an extensive SNMP trap list with a trap filter that is adjustable via SNMP). Network access (wired or wireless i.e. GSM/PCS Modem) allows over-the-air remote firmware uploading (FTP) with a load verification (and reversion) capability. There are three principle requirements to use SNMP with the MDR / Orion Radio Stations. 862-01881 Issue 13 Page 104 Orion and MDR Digital Radios 1. A Management Station that runs a SNMP Management Software package that is installed on a networked or stand-alone PC that can be connected to an Digital Indoor Unit either using a serial connection or an Ethernet connection. From the Management station, the agents within the Digital Indoor Units can be configured or polled for information. 2. Agent: The agent accepts SNMP GET, SET or GET-NEXT commands from the Management Application software and collects or adjusts information from the Digital Indoor Unit's MIB. 3. Management Information Base (MIB): the MIB is a database that is accessed based on the OID (object ID) the SNMP Manager has chosen. The Digital Indoor Unit uses an Enterprise MIB and a standard MIB (MIB II) to store or allow access to information relevant to the MDR / Orion link. 862-01881 Issue 13 Page 105 Orion and MDR Digital Radios B.2 The MIB Elements – OID (Object ID) DESCRIPTIONS Object ID Object name .1316 plessey .1316.1 products .1316.1.1 digitalradio .1316.1.1.1 mdrmte .1316.1.1.1.1 mdrmtePerformance .1316.1.1.1.2 mdrmteConfiguration .1316.1.1.1.3 mdrmteFault .1316.1.1.1.4 mdrmteAccess .1316.1.1.1.5 mdrmteRelayOutputs .1316.1.1.1.6 mdrmteOptoInputs .1316.1.1.1.1.1 mdrmtePayloadPerf Access Object Type Rights .1316.1.1.1.1.1.1 mdrmtePpTable SEQUENCE not-accessible .1316.1.1.1.1.1.1.1 mdrmtePpEntry MdrmtePpEntry not-accessible INTEGER read-only .1316.1.1.1.1.1.1.1.1 mdrmtePpIndex Description A Loss of Signal has been detected on the input to a tributary - there is one for each tributary (0, 1, 2, 3, ...) An Alarm Indication Signal has been detected on the input to a tributary - there is one for each tributary (0, 1, 2, 3, ...) The number of CRC4 or CRC6 errors seen on the selected tributary since the last time errors were cleared. .1316.1.1.1.1.1.1.1.2 mdrmtePpLOS INTEGER read-only .1316.1.1.1.1.1.1.1.3 mdrmtePpAIS INTEGER read-only .1316.1.1.1.1.1.2 mdrmteCrcErrors INTEGER read-only .1316.1.1.1.1.1.3 mdrmteCrcTribSelect INTEGER read-write .1316.1.1.1.1.1.4 mdrmteCrcLock INTEGER read-only The tributary selected for CRC checking. Indication of whether the CRC checking algorithm has locked onto a CRC frame signature in the payload data. read-only Reflects the number of assertions of the 'E' bits in selected tributary. .1316.1.1.1.1.1.5 mdrmteCrcEbitCnt .1316.1.1.1.1.2 mdrmteRFLinkPerf INTEGER .1316.1.1.1.1.2.1 mdrmteCarrierDetect INTEGER read-only .1316.1.1.1.1.2.2 mdrmteRSSI Gauge read-only 862-01881 Issue 13 Indicates if a RF Carrier has been detected by the RF Unit - if so, the header in the RF Packet has been identified as a potential valid packet - note however, that it could be received from another transmitter that uses the same header format A dBm value representative of the received signal level. The value detected is representative of the level that would be measured should a spread spectrum signal be input at the RF Unit's Diplexer RF Port - a CW (Continuous Wave) signal will appear to be 20 dB higher Page 106 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights .1316.1.1.1.1.2.3 mdrmteCurrentPER DisplayString read-only .1316.1.1.1.1.2.4 mdrmteMaximizedPER DisplayString read-only .1316.1.1.1.1.2.5 mdrmteLinkUnavailable INTEGER read-only .1316.1.1.1.1.2.6 mdrmteFrameUnlock INTEGER read-only Description This is the current Packet Error Rate and is based on the number of uncorrectable packets/blocks being detected by the FEC (Forward Error Correction) circuitry within the Digital Indoor Unit (based of the number of errored packets divided by the total number of packets transmitted in a measurement period of 250msec) This is the maximum Packet Error Rate detected during the last measurement period, based number of maximum number Based on G.826 criteria, this MIB element indicates RF Link Availability/Nonavailability The data that is transmitted across the RF Link is conveyed in a frame, compiled within .1316.1.1.1.1.2.7 mdrmteRemoteFrameUnlock INTEGER read-only .1316.1.1.1.1.2.8 mdrmteErrSecRatioExceeded INTEGER read-only Frame-lock (mdrmteFrameUnlock) as seen by the other end of the link is fed back here. The ESR is a ratio of the number of Errored seconds (one second periods within read-only The SESR is a ratio of the number of Severely Errored seconds (one second periods within .1316.1.1.1.1.2.9 mdrmteSevErrSecRatioExceeded INTEGER .1316.1.1.1.1.2.10 mdrmteBkgrndBlkErrRatioExceeded INTEGER read-only .1316.1.1.1.1.2.11 mdrmteMinorPERExceeded INTEGER read-only .1316.1.1.1.1.2.12 mdrmteMajorPERExceeded INTEGER read-only .1316.1.1.1.1.2.13 mdrmteCriticalPERExceeded INTEGER read-only The BBER is a ratio of the number of uncorrectable blocks/packets received This parameter indicates if the minor packet (uncorrectable by FEC) error rate has been exceeded based on the defined This parameter indicates if the major packet (uncorrectable by FEC) error rate has been exceeded based on the defined This parameter indicates if the critical packet (uncorrectable by FEC) error rate has been exceeded based on the defined read-only Indicates if autorecovery for the RF Unit settings had to be invoked This is the current Average Packet Error Rate and is based on the number of .1316.1.1.1.1.2.14 mdrmtePrevParamsRestored INTEGER .1316.1.1.1.1.2.15 mdrmteAveragePER DisplayString read-only .1316.1.1.1.1.2.16 mdrmteStartSweep INTEGER read-write .1316.1.1.1.1.2.17 mdrmteRssiSpectrum DisplayString read-only .1316.1.1.1.1.3 mdrmteG826 862-01881 Issue 13 This is used to start the spectral RSSI sweep. This contains the results of the sweep through the spectum of Page 107 Orion and MDR Digital Radios Object ID .1316.1.1.1.1.3.1 Object name mdrmteStatus Access Object Type Rights Description INTEGER Indicates if 'G.826-like' errored, severely errored and unavailable read-only .1316.1.1.1.1.3.2 mdrmteTotalSeconds Counter read-only .1316.1.1.1.1.3.3 mdrmteAvailableSeconds Counter read-only .1316.1.1.1.1.3.4 mdrmteUnavailableSeconds Counter read-only .1316.1.1.1.1.3.5 mdrmteErroredSeconds Counter read-only .1316.1.1.1.1.3.6 mdrmteSeverelyErroredSeconds Counter read-only Indicates the total number of seconds, both available and unavailable A period of unavailable time begins at the onset of ten consecutive SES events. A period of unavailable time begins at the onset of ten consecutive SES events. A one second period with one or more errored packets(uncorrectable packets) or at least one defect A one-second period which contains > 30% errored blocks or at least one defect. SES is a subset of ES. .1316.1.1.1.1.3.7 mdrmteErroredBlocks Counter read-only .1316.1.1.1.1.3.8 mdrmteBackgroundBlockErrors Counter read-only .1316.1.1.1.1.3.9 mdrmteErroredSecondsRatio DisplayString read-only .1316.1.1.1.1.3.10 mdrmteSeverelyErroredSecondsRat io DisplayString read-only A packet which has been identified as containing uncorrectable bits by the FEC circuitry An errored block not occurring as part of a SES. The ratio of ES to total seconds in available time during a fixed measurement interval. The ratio of SES to total seconds in available time during a fixed measurement interval. The ratio of Background Block Errors (BBE) to total blocks in available time .1316.1.1.1.1.3.11 mdrmteBackgroundBlockErrorRatio DisplayString read-only .1316.1.1.1.1.3.12 mdrmteDeprecated2 INTEGER write-only .1316.1.1.1.1.3.13 mdrmteCorrectedSymbols INTEGER read-only Deprecated This parameter lists the number of corrected symbols i.e. those corrected by the FEC .1316.1.1.1.1.4 mdrmteCounters read-only Indicates the total number of times an ethernet packet could not be buffered read-only Indicates the total number of times a link packet could not be buffered .1316.1.1.1.1.4.1 .1316.1.1.1.1.4.2 mdrmteLostEthRxPkts mdrmteLostLinkRxPkts Counter Counter .1316.1.1.1.1.4.3 mdrmteLostWaySideTxPkts Counter read-only .1316.1.1.1.1.4.4 mdrmteScc1FullCnt Counter read-only .1316.1.1.1.1.4.5 mdrmteScc2FullCnt Counter read-only .1316.1.1.1.1.4.6 mdrmteScc1UnderrunCnt Counter read-only .1316.1.1.1.1.4.7 mdrmteScc2UnderrunCnt Counter read-only Indicates the total number of times a wayside packet could not be buffered Indicates the total number of times SCC1 was full to capacity Indicates the total number of times SCC2 was full to capacity Indicates the total number of times SCC1 ran out of BDs Indicates the total number of times SCC2 ran out of BDs read-only Indicates the total number of times SCC2 received an aborted frame .1316.1.1.1.1.4.8 mdrmteScc2RxBdAbortCnt 862-01881 Issue 13 Counter Page 108 Orion and MDR Digital Radios Object ID .1316.1.1.1.1.4.9 Object name mdrmteScc2RxBdNonOctCnt Access Object Type Rights Description Counter Indicates the total number of times SCC2 received a Non octet aligned frame read-only .1316.1.1.1.1.4.10 mdrmteScc2RxBdCrcCnt Counter read-only .1316.1.1.1.1.4.11 mdrmteEtherTxRetries Counter read-only Indicates the total number of times SCC2 received a frame with a CRC error Indicates the total number of (collisions) packets that were retransmitted on ethernet .1316.1.1.1.1.4.12 mdrmteEtherTxDeferCnt Counter read-only .1316.1.1.1.1.4.13 mdrmteEtherTxHeartBeatCnt Counter read-only .1316.1.1.1.1.4.14 mdrmteEtherTxLateCollisions Counter read-only .1316.1.1.1.1.4.15 mdrmteEtherReTxLimit Counter read-only .1316.1.1.1.1.4.16 mdrmteEtherTxUnderrun Counter read-only Indicates the total number of frames deferred due to early collisions on ethernet Indicates the total number of times the collision inup was not asserted on ethernet Indicates the total number of late collisions on ethernet Indicates the total number of times the retransmission limit was reached on ethernet Indicates the total number of buffer underruns on ethernet read-only Indicates the total number of times carrier was lost on ethernet .1316.1.1.1.1.4.17 mdrmteEtherTxCarrierLost Counter .1316.1.1.1.1.4.18 mdrmteEtherRxLenErr Counter read-only .1316.1.1.1.1.4.19 mdrmteEtherRxNonOctet Counter read-only Indicates the total number of frame length violations received on ethernet Indicates the total number of non-octet aligned frames received on ethernet read-only Indicates the total number of (too) short frames received on ethernet read-only Indicates the total number of CRC errored frames received on ethernet read-only Indicates the total number of receiver overruns received on ethernet read-only Indicates the total number of collisioned frames received on ethernet .1316.1.1.1.1.4.20 .1316.1.1.1.1.4.21 .1316.1.1.1.1.4.22 .1316.1.1.1.1.4.23 mdrmteEtherRxShort mdrmteEtherRxCRCerr mdrmteEtherRxOverrun mdrmteEtherRxCollision Counter Counter Counter Counter .1316.1.1.1.1.4.24 mdrmteEtherJunkFrames Counter read-only .1316.1.1.1.1.4.25 mdrmteEtherShortFrames Counter read-only .1316.1.1.1.1.4.26 mdrmteEtherTxBdsFull Counter read-only .1316.1.1.1.1.4.27 mdrmteEtherRxPauseCnt Counter read-only .1316.1.1.1.1.4.28 mdrmteIdma1InUse Counter read-only 862-01881 Issue 13 Indicates the total number of invalid frames received on ethernet Indicates the total number of times the Ethernet frame received was too short. Indicates the total number of times the ethernet Tx BD queue was too full to insert data Indicates the total number of times the ethernet receiver was disabled due to lack of buffers. Indicates the total number of times IDMA controller 1 was already in use. memcpy() was used instead. Page 109 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights .1316.1.1.1.1.4.29 mdrmteIdma2InUse Counter read-only .1316.1.1.1.1.4.30 mdrmteLinkKnQueueFull Counter read-only .1316.1.1.1.1.4.31 mdrmteLinkTxBdsFull Counter read-only .1316.1.1.1.1.4.32 mdrmteKnEtherFramesLost Counter read-only .1316.1.1.1.1.4.33 mdrmteKnCraftFramesLost Counter read-only .1316.1.1.1.1.4.34 mdrmteKnLinkFramesLost Counter read-only Description Indicates the total number of times IDMA controller 2 was already in use. memcpy() was used instead. Indicates the total number of times a Kwiknet frame was deferred due to a lack of space in the AMX link queue. Indicates the total number of times the Rf Link Tx BD queue was too full to insert data Indicates the total number of times the Kwiknet queue was too full to insert Ethernet data Indicates the total number of times the Kwiknet queue was too full to insert SCC4 data Indicates the total number of times the Kwiknet queue was too full to insert SCC2 data .1316.1.1.1.1.4.35 mdrmteKnFramesTooShort Counter read-only .1316.1.1.1.1.4.36 mdrmteLinkVoidFrames Counter read-only .1316.1.1.1.1.4.37 mdrmteLinkRxPauseCnt Counter read-only Indicates the total number of times the Kwiknet buffer allocated was too short. Indicates the total number of overwritten frames received on the wireless PPP link Indicates the total number of times the link receiver was disabled due to lack of buffers. read-only Indicates the total number of times the Relay scripting server restarted. .1316.1.1.1.1.4.38 mdrmteRelayServerRestarts Counter .1316.1.1.1.1.4.39 mdrmteRelayClientRestarts Counter read-only .1316.1.1.1.1.4.40 mdrmteMuxEtherErrors Counter read-only .1316.1.1.1.1.4.41 mdrmteMuxBlockErrors Counter read-only .1316.1.1.1.1.4.42 mdrmteOuRxEtherCRCerrors Counter read-only .1316.1.1.1.1.5 mdrmteResetAllPerfData INTEGER write-only Indicates the total number of times the Relay scripting client restarted. The number of Ethernet errors reported by the FPGA The number of Block errors reported by the FPGA The number of Ethernet errors reported by the FPGA on the RFU Reset all parameters associated with Packet Error and G.826 measurements for the RF Link .1316.1.1.1.2.1 mdrmtePayloadConf .1316.1.1.1.2.1.1 mdrmteDataRate INTEGER read-write Configure the tributary data interface rate - either E1 or T1 .1316.1.1.1.2.1.2 mdrmteLineCodeType INTEGER read-only Deprecated .1316.1.1.1.2.1.3 mdrmtePcTable SEQUENCE not-accessible .1316.1.1.1.2.1.3.1 mdrmtePcEntry MdrmtePcEntry not-accessible INTEGER read-only .1316.1.1.1.2.1.3.1.1 mdrmtePcIndex .1316.1.1.1.2.1.3.1.2 mdrmtePcLabel DisplayString read-write E1/T1 Payload configuration tributary label .1316.1.1.1.2.1.3.1.3 mdrmtePcActive INTEGER read-write Defines whether tributaries are active or inactive .1316.1.1.1.2.1.4 SEQUENCE not-accessible mdrmteLineEncodingTable 862-01881 Issue 13 Page 110 Orion and MDR Digital Radios Object ID .1316.1.1.1.2.1.4.1 Object name Access Object Type Rights mdrmteLineEncodingEntry MdrmteLineEncoding Entry not-accessible .1316.1.1.1.2.1.4.1.1 mdrmteLineEncodingIndex .1316.1.1.1.2.1.4.1.2 mdrmteLineEncodingTribSelect .1316.1.1.1.2.1.4.1.3 mdrmteLineEncoding .1316.1.1.1.2.2 INTEGER INTEGER INTEGER Description read-only read-only Selects the trib, or group of tributaries to which encoding applies read-write Defines the line code types for the tributaries, either HDB3 or AMI for E1 mdrmteRFLinkConf .1316.1.1.1.2.2.1 mdrmteTxPower INTEGER read-write .1316.1.1.1.2.2.2 mdrmteBandPlan INTEGER read-write .1316.1.1.1.2.2.3 mdrmteTxFrequencyPlanD INTEGER read-write Allows setup of the output power available at the diplexer port of the RF Unit The MDR5800 RF Units operate in the 5.725 GHz to 5.850 GHz ISM frequency band. Frequency plan D allows independent control of transmit and receive frequencies. read-write Refer to the mdrmteTxFrequencyPlanD description This value is read from the RF Unit via the Digital Indoor Unit and defines whether it transmits in the .1316.1.1.1.2.2.4 mdrmteRxFrequencyPlanD INTEGER .1316.1.1.1.2.2.5 mdrmteTransmitBand INTEGER read-only .1316.1.1.1.2.2.6 mdrmteReserved2 INTEGER read-write .1316.1.1.1.2.2.7 mdrmteRegulations INTEGER read-only .1316.1.1.1.2.2.8 mdrmteAutoRecovery INTEGER read-write This parameter is read from the RF Unit via the Digital Indoor Unit and defines regulatory compliance of the RF Unit This feature is used if the user is installing a link from one side and there is no assistance on the opposite side of the link. It mitigates against the link failing and not being able to be .1316.1.1.1.2.2.9 mdrmteOURateOverride INTEGER read-write Depracated read-write A setable rate that allows a reduced transfer data rate over the RF Link read-only This value [MHz] is read back from the RF Unit and defines the transmit frequency of the RF Unit .1316.1.1.1.2.2.10 .1316.1.1.1.2.2.11 mdrmteOUDataRate mdrmteTxFrequencyCurrent INTEGER INTEGER .1316.1.1.1.2.2.12 mdrmteRxFrequencyCurrent INTEGER read-only .1316.1.1.1.2.2.13 mdrmteNonAutoBandPlan INTEGER read-write .1316.1.1.1.2.2.14 mdrmteNonAutoTxFreqPlanD INTEGER read-write 862-01881 Issue 13 This value [MHz] is read back from the RF Unit and defines the receive frequency of the RF Unit Same as mdrMTEBandPlan setting in this MIB group except Autorecovery is not enabled - this allows control of the Outdoor Same as mdrTxFrequencyPlanD setting in this MIB group except autorecovery is not enabled - this allows control of the Outdoor Page 111 Orion and MDR Digital Radios Object ID .1316.1.1.1.2.2.15 .1316.1.1.1.2.2.16 .1316.1.1.1.2.2.17 Object name mdrmteNonAutoRxFreqPlanD mdrmteNonAutoTxPower mdrmteRadioType Access Object Type Rights Description INTEGER read-write Same as mdrRxFrequencyPlanD setting in this MIB group except autorecovery is not enabled - this allows control of the Outdoor read-write Same as mdrTxPower setting in this MIB group except autorecovery is not enabled - this allows control of the Outdoor read-only This value is read from the RF Unit via the Digital Indoor Unit and defines INTEGER INTEGER .1316.1.1.1.2.2.18 mdrmteSevereErrorMargin INTEGER read-write .1316.1.1.1.2.2.19 mdrmteTimedMute INTEGER write-only Defines the percentage threshold (1-99) used when calculating in a one second period Initiates muting of transmitted signal for a short period to facilitate spectral analysis. .1316.1.1.1.2.3 mdrmteServiceChannel .1316.1.1.1.2.3.1 mdrmteScDataRate INTEGER read-write Bit rate used across the wayside service channel link .1316.1.1.1.2.3.2 mdrmteScDataBits INTEGER read-write The data width - can be 7 or 8 bits .1316.1.1.1.2.3.3 mdrmteScParity INTEGER read-write Serial channel - set to none, odd or even .1316.1.1.1.2.3.4 mdrmteScStopBits INTEGER read-write The nuber of stop bits can be set to 1 or 2 .1316.1.1.1.2.3.5 mdrmteScFlowControl INTEGER read-write Either hardware or no flow control is used read-write Allows the wayside service (serial) channel to be used as a diagnostics port .1316.1.1.1.2.3.6 mdrmteScStatusDump .1316.1.1.1.2.4 mdrmteGeneral INTEGER .1316.1.1.1.2.4.1 mdrmteStationName DisplayString read-write .1316.1.1.1.2.4.2 mdrmteIUSerialNumber DisplayString read-only .1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion DisplayString read-only .1316.1.1.1.2.4.4 mdrmteIUBootkernelVersion DisplayString read-only .1316.1.1.1.2.4.5 mdrmteOUBarCode INTEGER read-only .1316.1.1.1.2.4.6 mdrmteOUPICFirmwareVersion DisplayString read-only .1316.1.1.1.2.4.7 mdrmteOUPayloadSupport INTEGER read-only .1316.1.1.1.2.4.8 mdrmteDate DisplayString read-write 862-01881 Issue 13 The station name is stored in the Digital Indoor Unit in nonvolatile memory An electronic serial number is read from the Digital Indoor Unit - this number is unique The Digital Indoor Unit firmware number is the version of application firmware that is loaded into The Digital Indoor Unit bootkernel version is the version of boot firmware that is loaded into The RF Unit bar-code number is programmed into the RFU at time of manufacture and is read via the The RF Unit PIC firmware number is programmed into the RFU at time of manufactute and is read via the Deprecated This is a date record that is recovered from the Digital Indoor Unit's Real Time Clock Page 112 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights Description .1316.1.1.1.2.4.9 mdrmteTime DisplayString read-write .1316.1.1.1.2.4.10 mdrmteNOVRAMInit INTEGER read-write .1316.1.1.1.2.4.11 mdrmteFECBypass INTEGER read-write .1316.1.1.1.2.4.12 mdrmteFECCorrectableSymbols INTEGER read-write .1316.1.1.1.2.4.13 mdrmteTribCode DisplayString read-write .1316.1.1.1.2.4.14 mdrmteIndoorUnitBarCodeNumber DisplayString read-write .1316.1.1.1.2.4.15 mdrmteIndoorUnitPCBrevision INTEGER read-write This is a time record that is recovered from the Digital Indoor Unit's Real Time Clock If activated, the Nonvolatile memory is initialised to a set of default parameters This is primarily a laboratory test entry used to control whether the FEC circuitry within the This is primarily a laboratory test entry used to control the FEC correction power - 20 parity symbols This is a text entry code (80 characters ie 40 bytes) used to allow activation of tributaries on the Digital Indoor Units. This is a text entry code used to allow storage of the Digital Indoor Unit's bar code serial number (as seen on the outside of the This is a numeric entry code used to reflect the PCB revision number and modification status. read-write The station location is stored in the Digital Indoor Unit in nonvolatile memory .1316.1.1.1.2.4.16 mdrmteLocation DisplayString .1316.1.1.1.2.4.17 mdrmteOnePlusOne INTEGER read-write .1316.1.1.1.2.4.18 mdrmteMaxTribs INTEGER read-only .1316.1.1.1.2.4.19 mdrmteDefaultConfig INTEGER write-only .1316.1.1.1.2.4.20 mdrmteTotalTribs INTEGER read-only .1316.1.1.1.2.4.21 mdrmteCustomConfigSet INTEGER read-write .1316.1.1.1.2.4.22 mdrmteFpgaVersion INTEGER read-only .1316.1.1.1.2.4.23 mdrmteOuCommsRate INTEGER read-write .1316.1.1.1.2.4.24 mdrmteHdlcRateCap INTEGER read-write .1316.1.1.1.2.4.25 mdrmteOUSerialNo DisplayString read-only .1316.1.1.1.2.4.26 mdrmteApVersion DisplayString read-only .1316.1.1.1.2.5 mdrmteFirmware .1316.1.1.1.2.5.1 mdrmteFTPServerStatus INTEGER read-write .1316.1.1.1.2.5.2 mdrmteFlashNewFirmware INTEGER read-write 862-01881 Issue 13 Enables 'one-plus-one' dual-redundant (nonhitless) operation How many tribs can be used with the current trib code. Allows one to set one of four default-configurations. How many tribs in total on this version of IDU motherboard. Changes the way in which the default configurations work by pre-loading Firmware version of the FPGA. Data-rate of the ethernet link between the DIU and the RFU. Maximum Data-rate of the HDLC link between the DIU's (Mbit/sec + 1) The RF Unit serial number is programmed into the RFU at time of manufacture and is read via the The Firmware version number of the Atmel processor This allows activation/deactivation of the FTP server that runs in the Digital Indoor Unit and is This entry determines the time when the new version of firmware will be activated Page 113 Orion and MDR Digital Radios Object ID Object name .1316.1.1.1.2.5.3 mdrmtePlatformSupport .1316.1.1.1.2.6 mdrmteOutdoorUnit .1316.1.1.1.2.6.1 mdrmteOuPersonalityTable .1316.1.1.1.2.6.1.1 mdrmteOuPersonalityEntry .1316.1.1.1.2.6.1.1.1 mdrmteOuPersonalityIndex Access Object Type Rights Description DisplayString This indicates the hardware types supported by the firmware: read-only SEQUENCE not-accessible MdrmteOuPersonality Entry not-accessible INTEGER read-only .1316.1.1.1.2.6.1.1.2 mdrmteOuPersonalityActive INTEGER read-write Indicates whether this particular RFU personality is selected. .1316.1.1.1.2.6.1.1.3 mdrmteOuPersonalityDataRate INTEGER read-only Maximum raw data rate of the personality. .1316.1.1.1.2.6.1.1.4 mdrmteOuPersonalityModulation INTEGER read-only Modulation type. .1316.1.1.1.2.6.1.1.5 mdrmteOuPersonalityFpgaVersion INTEGER read-only FPGA version. .1316.1.1.1.2.6.1.1.6 mdrmteOuPersonalityRssiComp INTEGER read-only .1316.1.1.1.2.6.1.1.7 mdrmteOuPersonalityMinTxFreq INTEGER read-only .1316.1.1.1.2.6.1.1.8 mdrmteOuPersonalityMaxTxFreq INTEGER read-only .1316.1.1.1.2.6.1.1.9 mdrmteOuPersonalityMinRxFreq INTEGER read-only .1316.1.1.1.2.6.1.1.10 mdrmteOuPersonalityMaxRxFreq INTEGER read-only RSSI compensation factor used by the RFU Lowest allowed Tx frequency Highest allowed Tx frequency Lowest allowed Rx frequency Highest allowed Rx frequency .1316.1.1.1.2.6.1.1.11 mdrmteOuPersonalityPlanATxFreq INTEGER read-only Band plan A Tx frequency .1316.1.1.1.2.6.1.1.12 mdrmteOuPersonalityPlanARxFreq INTEGER read-only Band plan A Tx frequency .1316.1.1.1.2.6.1.1.13 mdrmteOuPersonalityPlanBTxFreq INTEGER read-only Band plan B Tx frequency .1316.1.1.1.2.6.1.1.14 mdrmteOuPersonalityPlanBRxFreq INTEGER read-only Band plan B Rx frequency .1316.1.1.1.2.6.1.1.15 mdrmteOuPersonalityPlanCTxFreq INTEGER read-only Band plan C Rx frequency .1316.1.1.1.2.6.1.1.16 mdrmteOuPersonalityPlanCRxFreq INTEGER read-only Band plan C Rx frequency .1316.1.1.1.2.6.1.1.17 mdrmteOuPersonalityMaxTxPower INTEGER read-only Maximum allowed Transmit Power .1316.1.1.1.2.6.1.1.18 mdrmteOuPersonalityMinTxPower INTEGER read-only Minimum allowed Transmit Power .1316.1.1.1.2.6.1.1.19 mdrmteOuPersonalityDefTxPower INTEGER read-only Default Transmit Power .1316.1.1.1.2.6.1.1.20 mdrmteOuPersonalityDescription DisplayString read-only Verbal description of this personality .1316.1.1.1.2.6.2 mdrmteOuPersonalities INTEGER read-only The number of FPGA personalities that the RFU has programmed .1316.1.1.1.2.6.3 mdrmteOuActivePersonality INTEGER read-write The currently active FPGA personality .1316.1.1.1.3.1 mdrmteInfo .1316.1.1.1.3.1.1 mdrmteLEDTable SEQUENCE not-accessible .1316.1.1.1.3.1.1.1 mdrmteLEDEntry MdrmteLEDEntry not-accessible .1316.1.1.1.3.1.1.1.1 mdrmteLEDIndex INTEGER read-only .1316.1.1.1.3.1.1.1.2 mdrmteLEDLabel DisplayString read-only .1316.1.1.1.3.1.1.1.3 mdrmteLEDState INTEGER read-only 862-01881 Issue 13 A group of LEDs on the front panel of the Digital Indoor Unit. A LED entry containing objects describing a particular LED. A unique value for each LED in the Digital Indoor Unit. Its value SYSTEM Green OK, Orange (RFU/DIU Comms Error), Red (RFU/DIU Comms Down). The current state of the LED - for a detailed description of functionality, see the mdrmteLEDLabel entry Page 114 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights Description The current colour of the LED - for a detailed description of functionality, see the mdrmteLEDLabel entry The number of Amber 'blips' that the LED is flashing .1316.1.1.1.3.1.1.1.4 mdrmteLEDColour INTEGER read-only .1316.1.1.1.3.1.1.1.5 mdrmteLEDHistoricAmberWarning INTEGER read-only .1316.1.1.1.3.1.1.1.6 mdrmteLEDHistoricRedError INTEGER read-only .1316.1.1.1.3.1.2 mdrmteOutdoorUnitComms INTEGER read-only .1316.1.1.1.3.1.3 mdrmteOutdoorUnitResetType INTEGER read-only .1316.1.1.1.3.1.4 mdrmteOutdoorUnitLockDetect INTEGER read-only The number of Red 'blips' that the LED is flashing Describes the state of Digital Indoor Unit communication with the RF Unit. This message is read from the RF Unit and identifies the last reason for a reset within the The transmit RF synthesizer, receive RF synthesizer and IF phased locked loop lock detect signals read-only In a One-Plus-One configuration, this tells you if this DIU is driving the .1316.1.1.1.3.1.5 mdrmtePayloadDrive INTEGER .1316.1.1.1.3.1.6 mdrmteLock INTEGER read-only .1316.1.1.1.3.1.7 mdrmtePeerPayloadDrive INTEGER read-only .1316.1.1.1.3.1.8 mdrmtePeerLock INTEGER read-only .1316.1.1.1.3.1.9 mdrmteOuEtherRate INTEGER read-only .1316.1.1.1.3.2 mdrmteSelfTest .1316.1.1.1.3.2.1 mdrmteFlash INTEGER read-only .1316.1.1.1.3.2.2 mdrmteDRAM INTEGER read-only .1316.1.1.1.3.2.3 mdrmteSRAM INTEGER read-only .1316.1.1.1.3.2.4 mdrmteLineInterface INTEGER read-only .1316.1.1.1.3.2.5 mdrmteFPGA INTEGER read-only In a One-Plus-One configuration, this tells you if this DIU is driving the In a One-Plus-One configuration, this tells you if the peer (standby) is driving the In a One-Plus-One configuration, this tells you if the peer (standby) is driving the The current (actual) Datarate of the ethernet link between the DIU and the RFU. Identifies pass/fail status of the Digital Indoor Unit's application flash Identifies pass/fail status of the Digital Indoor Unit's Dynamic RAM Identifies pass/fail status of the Digital Indoor Unit's Static RAM Identifies pass/fail status of the Digital Indoor Unit's Line Interface IC Identifies pass/fail status of the Digital Indoor Unit's FPGA interface registers to the microprocessor .1316.1.1.1.3.2.6 mdrmteFEC INTEGER read-only .1316.1.1.1.3.2.7 mdrmteRealTimeClock INTEGER read-only .1316.1.1.1.3.2.8 mdrmteIndoorUnitResetType INTEGER read-only Identifies pass/fail status of the Digital Indoor Unit's FEC IC electrical interface Identifies pass/fail status of the Digital Indoor Unit's Real Time Clock This message is read from the Digital Indoor Unit and identifies the last reason for a reset within the read-write Entry defines the loopback mode of a radio station in terms of loopback at either read-write This is the number of seconds the loopback will run for until it times out .1316.1.1.1.3.2.9 .1316.1.1.1.3.2.10 mdrmteLoopbackMode mdrmteLoopbackTimeOut 862-01881 Issue 13 INTEGER INTEGER Page 115 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights .1316.1.1.1.3.2.11 mdrmteOuTemperature DisplayString read-only .1316.1.1.1.3.2.12 mdrmteOuEtherPhy INTEGER read-only .1316.1.1.1.3.2.13 mdrmteEEprom INTEGER read-only .1316.1.1.1.3.3 mdrmteTrapManagement .1316.1.1.1.3.3.1 mdrmteTrapFilter INTEGER read-write .1316.1.1.1.3.3.2 mdrmteNumberTrapManagers INTEGER read-only .1316.1.1.1.3.3.3 mdrmteTrapManagerTable .1316.1.1.1.3.3.3.1 mdrmteTrapManagerEntry SEQUENCE not-accessible MdrmteTrapManager Entry not-accessible .1316.1.1.1.3.3.3.1.1 mdrmteTrapManagerIndex INTEGER Description This is the measured temperature in the Outdoor unit (if supported) in degrees Celcius Identifies pass/fail status of the ethernet phy to the RFU Identifies pass/fail status of the Digital Indoor Unit's EEPROM Alarms within the MDR product are classfied as critical, major, minor or informational. The trap This entry shows the number of trap managers allowed read-only .1316.1.1.1.3.3.3.1.2 mdrmteTrapManagerIP IpAddress read-write .1316.1.1.1.3.3.3.1.3 mdrmteTrapManagerComm DisplayString read-write This is the IP address of the management station that is set up to detect and act upon This is the 'SNMP community name' used for dispatch of traps read-write Defines whether a particular Trap Manager is active or inactive .1316.1.1.1.3.3.3.1.4 mdrmteTrapManagerActive .1316.1.1.1.3.4 INTEGER mdrmtePerfTrapThreshold .1316.1.1.1.3.4.1 mdrmteMinorPERThreshold DisplayString read-write .1316.1.1.1.3.4.2 mdrmteMajorPERThreshold DisplayString read-write .1316.1.1.1.3.4.3 mdrmteCriticalPERThreshold DisplayString read-write Defines the threshold used as a checking criterion for the Minor PER (Packet Error Rate) Defines the threshold used as a checking criterion for the Major PER (Packet Error Rate) Defines the threshold used as a checking criterion for the Critical PER (Packet Error Rate) Defines the threshold used as a checking criterion for the Errored Second Ratio Defines the threshold used as a checking criterion for the Severely Errored Second Ratio Defines the threshold used as a checking criterion for the Background Block Error Ratio .1316.1.1.1.3.4.4 mdrmteErrSecRatioThreshold DisplayString read-write .1316.1.1.1.3.4.5 mdrmteSevErrSecRatioThreshold DisplayString read-write .1316.1.1.1.3.4.6 mdrmteBkgrndBlkErrRatioThreshold DisplayString read-write .1316.1.1.1.3.5 mdrmteEventLogTable .1316.1.1.1.3.5.1 mdrmteEventLogEntry SEQUENCE not-accessible MdrmteEventLogEntr not-accessible .1316.1.1.1.3.5.1.1 mdrmteEventIndex INTEGER read-only .1316.1.1.1.3.5.1.2 mdrmteEventDate DisplayString read-only Lists the date on which the event occurred .1316.1.1.1.3.5.1.3 mdrmteEventTime DisplayString read-only Lists the time when the event occurred .1316.1.1.1.3.5.1.4 mdrmteEventType INTEGER read-only Lists the type of event informational, minor, major or critical .1316.1.1.1.3.5.1.5 mdrmteEventDescription DisplayString read-only Textual description of the logged event 862-01881 Issue 13 Page 116 Orion and MDR Digital Radios Object ID Object name Access Object Type Rights Description .1316.1.1.1.3.6 mdrmteClearEventLog INTEGER write-only This entry is used to clear the Event Log .1316.1.1.1.3.7 mdrmteResetAllFaults INTEGER write-only .1316.1.1.1.3.8 mdrmteEnableDebug INTEGER read-write .1316.1.1.1.3.9 mdrmteErrorWindow INTEGER read-write .1316.1.1.1.3.10 mdrmteTrapData DisplayString read-only .1316.1.1.1.3.11 mdrmteLogCorrectedSymbols INTEGER read-write .1316.1.1.1.3.13 mdrmteHideHistoricLeds INTEGER read-write .1316.1.1.1.3.12 mdrmteEngineering This entry is used to This entry is used to enable test and debugging features This entry is used to set the time period in minutes during Textual description or data relating to a trap Enable or disable periodic logging of corrected sybmols Enable or disable the 'historic' flashing on the LEDs .1316.1.1.1.3.12.1 mdrmteDataStreamStatus INTEGER read-only .1316.1.1.1.3.12.2 mdrmteFramingSchedule INTEGER read-only .1316.1.1.1.3.12.3 mdrmteFrameTribCnt INTEGER read-only Status bits for the RF Unit and tribs during during production tests. The current framing schedule selected on the FPGA The number of tribs supported by the framing structure in use read-write Loop one Digital Indoor Unit to another without RF Units for production tests .1316.1.1.1.3.12.4 mdrmteIuBackToBack INTEGER .1316.1.1.1.3.12.5 mdrmteWaysideFeedsOu INTEGER read-write .1316.1.1.1.4.1 mdrmteEthernetIPAddress IpAddress read-write Feed the Wayside channel to the RF Unit for production tests The IP address associated with product's Ethernet port. .1316.1.1.1.4.2 mdrmteEthernetNetMask IpAddress read-write The netmask associated with the Ethernet port .1316.1.1.1.4.3 mdrmteMaxNumUsers INTEGER read-only If the firmware is compiled with the security feature read-only If the firmware is built with the security feature switched on, users .1316.1.1.1.4.4 mdrmteMaxNumActiveUsers INTEGER .1316.1.1.1.4.5 mdrmteNumActiveUsers Gauge read-only If the firmware is built with the security feature switched on, users .1316.1.1.1.4.6 mdrmteUserTable SEQUENCE not-accessible Deprecated .1316.1.1.1.4.6.1 mdrmteUserEntry MdrmteUserEntry not-accessible Deprecated .1316.1.1.1.4.6.1.1 mdrmteUserIndex INTEGER read-only Deprecated read-write If the firmware is built with the security feature switched on, users write-only If the firmware is built with the security feature switched on, users .1316.1.1.1.4.6.1.2 .1316.1.1.1.4.6.1.3 mdrmteUserName mdrmteUserPassword DisplayString DisplayString .1316.1.1.1.4.6.1.4 mdrmteUserAccessLevel INTEGER read-write .1316.1.1.1.4.6.1.5 mdrmteUserActive INTEGER read-write .1316.1.1.1.4.6.1.6 mdrmteUserAdd INTEGER write-only .1316.1.1.1.4.6.1.7 mdrmteUserDelete INTEGER write-only 862-01881 Issue 13 If the firmware is built with the security feature switched on, users Indicates if a user is active or not based on password entry In security-enabled mode, allows an administrator to add users In security-enabled mode, allows an administrator to delete users Page 117 Orion and MDR Digital Radios Object ID .1316.1.1.1.4.7 Object name mdrmteRFLinkIPAddress Access Object Type Rights Description IpAddress PPP IP address for the RF Link. The user need not adjust this parameter read-write .1316.1.1.1.4.8 mdrmteRFLinkNetMask IpAddress read-write .1316.1.1.1.4.9 mdrmteRemoteIPAddress IpAddress read-write .1316.1.1.1.4.10 mdrmteElementManagerIPAddress IpAddress read-write .1316.1.1.1.4.11 mdrmteElementManagerNetMask IpAddress read-write .1316.1.1.1.4.12 mdrmteIPNegotiable INTEGER read-write .1316.1.1.1.4.13 mdrmtePPPisDefaultRoute INTEGER read-write Default PPP IP address for the the element manager port - 10.13.1.1 IP netmask for the Element Manager PPP port Determines if the local PPP IP address is negotiable or not - does not need to be adjusted by Determines if PPP interface is the default route - does not need to be adjusted by Manually added static routes. (Only activated after system reset) .1316.1.1.1.4.14 mdrmteStaticRouteTable .1316.1.1.1.4.14.1 mdrmteStaticRouteEntry .1316.1.1.1.4.14.1.1 mdrmteStaticRouteIndex INTEGER mdrmteStaticRouteIPAddressDestin IpAddress ation read-only read-write read-write Where to forward to .1316.1.1.1.4.14.1.5 mdrmteStaticRouteIPAddressMask IpAddress mdrmteStaticRouteIPAddressNextH op IpAddress mdrmteStaticRouteInterfaceForNext Hop INTEGER Ultimate destination net mask, 255.255.255.255 if destination is host address read-write .1316.1.1.1.4.15 mdrmteBridgeEnable INTEGER read-write .1316.1.1.1.4.16 mdrmteEthernetFullDuplex INTEGER read-write .1316.1.1.1.4.17 mdrmteDefaultGateway IpAddress read-write Interface (net) for nexthop Determines if the system is to act as a transparent bridge for all ethernet packets received. Determines if the ethernet interface is full- or halfduplex. Default Gateway (Only activated after system reset) .1316.1.1.1.4.18 mdrmteDefaultGWInterface INTEGER read-write .1316.1.1.1.4.19 mdrmteElementManagerPeerIP IpAddress read-write .1316.1.1.1.4.20 mdrmteMacLearning INTEGER read-write .1316.1.1.1.4.21 mdrmteEnableDHCP INTEGER read-write .1316.1.1.1.4.22 mdrmteClearArpCache INTEGER read-write .1316.1.1.1.4.23 mdrmteMacAddress DisplayString read-write .1316.1.1.1.4.24 mdrmteSnmpSetCommunity DisplayString write-only .1316.1.1.1.4.14.1.2 .1316.1.1.1.4.14.1.3 .1316.1.1.1.4.14.1.4 862-01881 Issue 13 SEQUENCE not-accessible MdrmteStaticRouteEn try not-accessible PPP IP netmask for the RF Link. The user need not adjust this parameter Default PPP IP address for the other end of the link. The user need not adjust this parameter read-write Default Gateway interface Default PPP IP address for the the PC connected to the element manager serial port. Enable or disable the ability to learn what MAC addresses are present locally. Enable or disable the DHCP client on ethernet. If enabled, the locally stored IP Delete all cached MAC addresses in the ARP table 3-octet substring of the ethernet MAC address excluding the Plessey RFUI. Up to 31 octets defining the SNMP Write community string for READ/WRITE access. Page 118 Orion and MDR Digital Radios Object ID Object name .1316.1.1.1.4.25 mdrmteSnmpGetCommunity .1316.1.1.1.5.1 mdrmteRelay1 .1316.1.1.1.5.1.1 .1316.1.1.1.5.1.2 mdrmteRelay1Label mdrmteRelay1OpenStateLabel Access Object Type Rights Description DisplayString write-only Up to 31 octets defining the SNMP Read community string for READ access. read-write A short, descriptive name indicating the primary funtion of the relay, read-write A short, descriptive name indicating the primary funtion of the relay DisplayString DisplayString .1316.1.1.1.5.1.3 mdrmteRelay1ClosedStateLabel DisplayString read-write A short, descriptive name indicating the primary funtion of the relay .1316.1.1.1.5.1.4 mdrmteRelay1Reserved INTEGER read-write Reserved. .1316.1.1.1.5.1.5 mdrmteRelay1CurrentState INTEGER read-write .1316.1.1.1.5.1.7 mdrmteRelay1Latching INTEGER read-write .1316.1.1.1.5.1.6 mdrmteRelay1ScriptTable .1316.1.1.1.5.1.6.1 mdrmteRelay1ScriptEntry SEQUENCE not-accessible MdrmteRelay1ScriptE ntry not-accessible .1316.1.1.1.5.1.6.1.1 mdrmteRelay1ScriptIndex INTEGER The current state of the relay. Used to activate/deactivate a relay. Indicates whether the relay will be latched by Scripting events, or will follow the state. read-only .1316.1.1.1.5.1.6.1.2 mdrmteRelay1ScriptID INTEGER read-only .1316.1.1.1.5.1.6.1.3 mdrmteRelay1ScriptActiveLocal INTEGER read-write .1316.1.1.1.5.1.6.1.4 mdrmteRelay1ScriptActiveRemote INTEGER read-write Defines which of the listed alarms can cause a relay to activate Defines if the script is active or not for local relay activation Defines if the script is active or not for remote relay activation read-write A short, descriptive name indicating the primary funtion of the relay. read-write A short, descriptive name indicating the primary funtion of the relay .1316.1.1.1.5.2 .1316.1.1.1.5.2.1 .1316.1.1.1.5.2.2 mdrmteRelay2 mdrmteRelay2Label mdrmteRelay2OpenStateLabel DisplayString DisplayString .1316.1.1.1.5.2.3 mdrmteRelay2ClosedStateLabel DisplayString read-write A short, descriptive name indicating the primary funtion of the relay .1316.1.1.1.5.2.4 mdrmteRelay2Reserved INTEGER read-write Reserved. .1316.1.1.1.5.2.5 mdrmteRelay2CurrentState INTEGER read-write .1316.1.1.1.5.2.7 mdrmteRelay2Latching INTEGER read-write .1316.1.1.1.5.2.6 mdrmteRelay2ScriptTable .1316.1.1.1.5.2.6.1 mdrmteRelay2ScriptEntry SEQUENCE not-accessible MdrmteRelay2ScriptE not-accessible ntry .1316.1.1.1.5.2.6.1.1 mdrmteRelay2ScriptIndex INTEGER read-only .1316.1.1.1.5.2.6.1.2 mdrmteRelay2ScriptID INTEGER read-only .1316.1.1.1.5.2.6.1.3 mdrmteRelay2ScriptActiveLocal INTEGER read-write .1316.1.1.1.5.2.6.1.4 mdrmteRelay2ScriptActiveRemote INTEGER read-write 862-01881 Issue 13 The current state of the relay. Used to activate/deactivate a relay. Indicates whether the relay will be latched by Scripting events, or will follow the state. Defines which of the listed alarms can cause a relay to activate Defines if the script is active or not for local relay activation Defines if the script is active or not for remote relay activation Page 119 Orion and MDR Digital Radios Object ID .1316.1.1.1.5.3 Object name mdrmteRelayScriptServerPort Access Object Type Rights Description INTEGER This specifies the IP port number to be used by the Relay scripting server read-write .1316.1.1.1.5.4 mdrmteRelayClientComms INTEGER read-only .1316.1.1.1.5.5 mdrmteRelayScriptRemotePollTime INTEGER read-write .1316.1.1.1.5.6 mdrmteActiveEventsTable not-accessible This indicates the state of the Relay Scripting clientserver socket. This specifies the poll interval for remote scripting updates in seconds. Shows all the currently active events (even if scripting on the event is disabled.) .1316.1.1.1.5.6.1 mdrmteActiveEventsEntry SEQUENCE MdrmteActiveEvents Entry .1316.1.1.1.5.6.1.1 mdrmteActiveEventsIndex INTEGER read-only Index .1316.1.1.1.5.6.1.2 mdrmteActiveEventsLabel INTEGER read-only Name of the event .1316.1.1.1.5.6.1.3 mdrmteActiveEvents INTEGER read-only .1316.1.1.1.5.6.1.4 mdrmteActiveRemoteEvents INTEGER read-only .1316.1.1.1.5.7 mdrmteRelayScriptingEnable INTEGER read-write Defines whether events are active or inactive Defines whether remote events are active or inactive This enables or disables relay scripting. Both near and far units must have the same setting. .1316.1.1.1.6.1 mdrmteOptoInput1 read-write A short, descriptive name indicating the primary funtion of the contactclosure input read-only Indicates if the opto input contact-closure input is active (on) or not (off) read-write A short, descriptive name indicating the primary funtion of the contactclosure input read-only Indicates if the opto input contact-closure input is active (on) or not (off) .1316.1.1.1.6.1.1 mdrmteOptoInput1Label .1316.1.1.1.6.1.2 mdrmteOptoInput1State .1316.1.1.1.6.2 mdrmteOptoInput2 .1316.1.1.1.6.2.1 .1316.1.1.1.6.2.2 mdrmteOptoInput2Label mdrmteOptoInput2State 862-01881 Issue 13 DisplayString INTEGER DisplayString INTEGER not-accessible Page 120 Orion and MDR Digital Radios B.3 The MIB elements – TRAP DESCRIPTIONS mdrmteTrapUndefined : Informational mdrmteTrapPayloadLOS : Critical Indicates a Loss of Signal identified on the INPUT TO a tributary mdrmteTrapPayloadAIS : Critical Indicates an Alarm Indication Signal ' all 1's ' identified/sensed on the INPUT TO a tributary mdrmteTrapLinkUnavailable : Critical Indicates, based on G.826 criteria if the RF Link has become unavailable MdrmteTrapLinkFrameUnlock : Critical Indicates a Frame Unlock condition associated with the Digital Indoor Unit mdrmteTrapLinkOuSynthUnlock : Critical Indicates if a synthesizer unlock condition was identified in the RF Unit mdrmteTrapLinkMinorPERExceeded : Minor Indicates the minor packet error rate threshold was exceeded mdrmteTrapLinkMajorPERExceeded : Major Indicates the major packet error rate threshold was exceeded mdrmteTrapLinkCriticalPERExceeded : Critical Indicates the critical packet error rate threshold was exceeded 10 mdrmteTrapLinkESRExceeded : Minor Indicates the Link Errored Second Ratio Threshold limit was exceeded 11 mdrmteTrapLinkSESRExceeded : Critical Indicates the Link Severely Errored Second Ratio threshold limit was exceeded 12 mdrmteTrapLinkBBERExceeded : Minor Indicates the Link Background Block Error Rate threshold limit was exceeded 13 mdrmteTrapFTPUploadDone : Informational Indicates FTP Upload done 14 mdrmteTrapFlashEraseFail : Informational Indicates failure to erase Application flash 15 mdrmteTrapFirmwareUpgradePass : Informational Indicates that firmware was uploaded successfully 16 mdrmteTrapFirmwareUpgradeFail : Informational Indicates that there was a firmware upload failure 17 mdrmteTrapInterstationCommsTimeOut : Major Indicates an interstation communications timeout 18 mdrmteTrapInterstationCommsInvalidResponse : Minor Indicates a communications error on the interstation overhead link 19 mdrmteTrapOUCommsTimeOut : Major Indicates an RF Unit communications timeout 20 mdrmteTrapOUCommsInvalidResponse : Minor Indicates an RF Unit communications error - an invalid response was received 21 MdrmteTrapOUCommsTxFail Indicates RF Unit communications transmit failure 22 mdrmteTrapSSPCRCError : Minor Simple Serial Protocol CRC error identified 23 mdrmteTrapSSPLengthError : Minor Simple Serial Protocol Length error identified 24 mdrmteTrapOptoInput1Off : Major Contact closure input off state detected - Opto 1 25 mdrmteTrapOptoInput1On : Major Contact closure input off state detected- Opto 1 26 mdrmteTrapOptoInput2Off : Major Contact closure input off state detected - Opto 2 27 mdrmteTrapOptoInput2On : Major Contact closure input on state detected - Opto 2 28 mdrmteTrapUserLoginFailed : Informational With security MODE ON - indicates a user attempted to log on and the attempt failed 29 mdrmteTrapUserLogoutFailed : Informational With security MODE ON - indicates a user attempted to log out and the attempt failed 30 MdrmteTrapUserAddFailed : Informational With security MODE ON - indicates there was an attempt to add a user, but the attempt failed. 31 mdrmteTrapUserDeleteFailed : Informational With security MODE ON - indicates there was an attempt to remove/delete a user, but the attempt failed. 32 mdrmteTrapUserLogIn : Informational With security MODE ON - indicates a user logged in. 33 mdrmteTrapUserLogOut : Informational With security MODE ON - indicates a user logged out. 34 mdrmteTrapUserAdd : Informational With security MODE ON - indicates a user was added successfully. 35 mdrmteTrapUserDelete : Informational With security MODE ON - indicates a user was deleted successfully. 36 mdrmteTrapOUSetBandPlan : Informational Indicates the RF Unit channel/band plan was changed. 37 mdrmteTrapOUSetTxChannel : Informational Indicates the RF Unit transmit frequency was changed. 38 mdrmteTrapOUSetRxChannel : Informational Indicates the RF Unit receive frequency was changed. 862-01881 Issue 13 Page 121 Orion and MDR Digital Radios 39 mdrmteTrapOUEepromWrite : Minor Indicates there was an attempt to write to the RF Unit EEPROM. 40 MdrmteTrapOUSetTxPower : Informational Indicates there was an attempt to change the transmit power. 41 MdrmteTrapOUSetPNCode Deprecated 42 MdrmteTrapOUSetAutoRecovery Indicates there was an attempt to change the 'auto recovery' setting. 43 MdrmteTrapOUProgramConfig Deprecated 44 mdrmteTrapOUChangeRFLoopback : Informational Indicates a change the RFU RF Loopback setting was implemented. 45 mdrmteTrapOUChangeBBPLoopback : Informational Indicates a change the Baseband Processor Loopback setting was implemented. 46 mdrmteTrapOUWriteBBP : Minor Indicates there was an attempt to write to the Baseband Processor. 47 mdrmteTrapSetDate : Informational Indicates the Digital Indoor Unit date was adjusted. 48 mdrmteTrapSetTime : Informational Indicates the Digital Indoor Unit time was adjusted. 49 mdrmteTrapSynchronizeSwRTC : Informational Indicates the Digital Indoor Unit's time was synchronized with its realtime clock. 50 MdrmteTrapSetRelayLabel A relay label was changed. 51 MdrmteTrapSetRelayOpenStateLabel A relay open-state label was changed. 52 MdrmteTrapSetRelayClosedStateLabel A relay closed-state label was changed. 53 mdrmteTrapSetRelayDefaultState : NA Deprecated 54 mdrmteTrapSetRelayCurrentState : Informational Relay's current state has changed 55 MdrmteTrapRelayScriptEnable Relay scripting is enabled. 56 MdrmteTrapRelayScriptDisable Relay scripting is disabled. 57 mdrmteTrapGetEventLog : Informational Digital Indoor Unit's event log is being accessed. 58 mdrmteTrapClearEventLog : Informational Digital Indoor Unit's event log is being cleared. 59 mdrmteTrapSelfTestFailure : Major Digital Indoor Unit's self test failed. 60 mdrmteTrapProcessorReset : Critical There was an Digital Indoor Unit processor reset. 61 MdrmteTrapEtherRx There was an Digital Indoor Unit Receive Ethernet buffer error. 62 mdrmteTrapTest : Informational Test trap 63 MdrmteTrapGenericText Test trap 64 mdrmteTrapGenericText_Data Test trap 65 mdrmteTrapGenericText_DecData Test trap 66 mdrmteTrapSocket_Error Test trap 67 mdrmteLog_Link_Status : Informational The Event Log was cleared, so a summary of the status has been logged. 68 mdrmteLog_Link_Errors : Informational One or more packet errors occurred in the last error window. 69 mdrmteLog_Link_Corrections : Informational One or more corrected symbols occurred in the last error window. 70 mdrmteLocRelayScriptOpen : Minor A relay opened as a result of a local relay scripting event. 71 mdrmteLocRelayScriptClose : Minor A relay closed as a result of a local relay scripting event. 72 mdrmteRemRelayScriptOpen : Minor A relay opened as a result of a remote relay scripting event. 73 MdrmteRemRelayScriptClose : Minor A relay closed as a result of a remote relay scripting event. 74 mdrmteRemScriptEvent : Minor A remote event occurred which will be processed by relay scripting. 75 MdrmteTrapLinkFrameUnlockAgain Indicates a Frame Unlock condition associated with the Digital Indoor Unit 76 MdrmteTrapOUSetFrequencies Indicates the RF Unit receive frequencies were changed. 77 MdrmteTrapOUSetPersonality Indicates the RF Unit FPGA personality was changed. 862-01881 Issue 13 Page 122 Orion and MDR Digital Radios C Appendix: SETUP OF A PC (WIN 95, 98, NT) TO ALLOW PINGING OF A ‘REMOTE’-CONFIGURED DIGITAL INDOOR UNIT The following diagram shows the default (factory) network IP addresses assigned to the various network ports on the MDR / Orion System: ROUTING CONFIGURATION C.1 IP CONFIGURATION OF THE MDR / Orion – ROUTING CONFIGURATION M DR / Orion - ROUTING CONFIGURATION PPP W IRELESS Ethernet 10-BaseT 10.2.1.2 10.10.9.9 10.10.9.10 10.11.1.2 10.13.1.1 10.12.1.1 PPP RS232 PPP RS232 "NEAR" "FAR" Ethernet 10-BaseT Hub Browser/NMS 10.13.1.2 (IP Auto assigned) "Server assigned" Laptop computer Browser/NMS 10.12.1.2 (IP Auto assigned) "Server assigned" Laptop computer Browser/NMS 10.2.1.3 (IP User assigned) Laptop computer To allow pinging of a DIU configured as a "remote unit" i.e. with an IP address of (10.11.1.2) when the PC has a 10.2.1.3 IP address, 10.2.1.2 default gateway and netmask 255.255.0.0, create batch files. Batch file 1 - addroute.bat route add 10.11.0.0 mask 255.255.0.0 10.2.1.3 Batch file 1 adds a route so that the IP stack on the PC "knows" where to send IP packets destined for the net 10.11.0.0 862-01881 Issue 13 Page 123 Orion and MDR Digital Radios If you want to delete the route, use Batch file 2 - delroute.bat route delete 10.11.0.0 If you want a screen printout of the routes the PC is using, use the command line entry: route print NOTE DO NOT ALLOW AN RF LINK TO ESTABLISH BEFORE DOING A PING on the remote DIU (with 10.11.1.2 as an IP address) - if the RF link was established before, use the front panel button "position 3" to reset the DIU before attempting to ping. 862-01881 Issue 13 Page 124 Orion and MDR Digital Radios C.2 IP CONFIGURATION OF THE MDR / Orion – BRIDGING CONFIGURATION The following diagram shows the default (factory) network IP addresses assigned to the various network ports on the MDR / Orion System: BRIDGING CONFIGURATION. NOTE For most networks, bridging is the preferred IP configuration. MDR / Orion - BRIDGING CONFIGURATION PPP W IRELESS Ethernet 10-BaseT 192.168.1.2 192.168.4.2 192.168.4.3 Ethernet 10-BaseT 192.168.1.3 192.168.2.2 192.168.3.3 PPP RS232 PPP RS232 "NEAR" "FAR" Hub Browser/NM S 192.168.2.3 (IP Auto assigned) "Server assigned" Browser/NM S 192.168.3.2 (IP Auto assigned) "Server assigned" Laptop computer Laptop computer Browser/NM S 192.168.1.4 (IP User assigned) Laptop com puter NOTE The netmask for all the 192.168.x.x addresses is 255.255.255.0 862-01881 Issue 13 Page 125 Orion and MDR Digital Radios D Appendix: MDR5800 hardware VERSION 1, 2.x DIFFERENCES, COMPATIBILITY SUMMARY Version 1 hardware (Indoor and RF Units) is incompatible with Version 2.x hardware. The Digital Indoor Unit /RF Unit Twisted Pair Data Interconnection for Version 2 hardware uses 2 twisted pair cables to convey payload and RF Unit control signals whereas Version 1 hardware uses 4 twisted pair cables. Notes : Version 2.x firmware (can be uploaded into the Digital Indoor Unit using the NMS’s Maintenance option) that can be used in Version 1.x hardware must be obtained from the product manufacturer. The file is not the same file that is used with Version 2.x hardware. Updated RSSI and Power control functionality have been added to Version 2.x hardware and firmware. Version 2.x firmware has 1. FTP upload functionality (needs to be activated via the MIB) 2. IP Bridging functionality (half and full duplex – selectable via the MIB). Appropriate DIU hardware must be used. 3. Band Plan C 4. Refer to the MIB section of this manual and look for the † symbol to see what MIBrelated functionality is in place/activated/planned for Version 2.x + firmware. 5. Functional RF Loopback built-in test feature. 6. Ethernet packet error monitoring and buffer monitoring added to MIB 7. E1 CRC4 payload monitoring added to MIB (only applicable for a single tributary) 8. Digital Indoor Unit PCB hardware revision added to MIB 9. Periodic reporting of RF Link packet errors (adjustable in time, defaulted to 10 minutes) added to MIB. Version 2.x NMS has 1. Ability to allow the user to connect to the Digital Indoor Unit using PPP (via a serial cable interface to the DIU’s front panel Element Manager RS232 port) or via Ethernet (via the front panel RJ45 connector: 10BaseT). 2. Graphical Spectrum Analyzer display By default, firmware provided for the Digital Indoor Units does not provide a secure login feature (thereby limiting a user’s ability to ‘set’ MIB variables). Suitably adapted firmware versions (dependent on hardware version) need to be requested from the product manufacturer to allow activation of this feature. 862-01881 Issue 13 Page 126 Orion and MDR Digital Radios MDR / ORION DIGITAL INDOOR UNIT FIRMWARE UPGRADE NOTICE MDR Version 2 hardware Digital Indoor Units are identified as having 200+ serial numbers, RF Units have 250+ serial numbers. If upgrading Digital Indoor Units to use V2.02+ DIU firmware, upgrade the DIU firmware on BOTH sides of the RF Link. Note that firmware upgrades of Version 1 MDR Digital Indoor Unit hardware do not require setting up of the PCB Issue in the MIB i.e. mdrmteIndoorUnitPCBrevision element. Upgrade to DIU firmware Version 2+ of Version 1 hardware will NOT give improved RSSI functionality. This is only achieved with Version 2 hardware or modified version 1 hardware. Full Duplex Ethernet Capability on MDR DIUs As a standard setting for mdrmteIndoorUnitPCBrevision, use MIB selection Issue_2. HOWEVER, if an appropriate Indoor PCB modification (made at the factory) has been made to allow Full Duplex Ethernet operation, the Issue_2_Mod_A selection option in the MIB MUST be used. Per trib line code selectivity on MDR DIUs MDR Digital Indoor Units that are modified to allow T1 line codes to be selected uniquely on a per trib basis are identified by a hardware version number of 2.1AT. These Digital Indoor Units must only be operated with firmware version 4.09 and higher. The PCB revision of these units should also be set to 5. Table 14 indicates the compatibility between different indoor and RF Unit types. The DIU firmware types required to provide the compatibility between different hardware types are listed in. NOTE Different Digital Indoor Unit firmware versions may be required to provide compatibility between different indoor and RF Unit types. Table 14 Indoor - RF Unit compatibility matrix. Hardware Type MDR DIU ORION 10 DIU ORION 25 DIU ORION 50 DIU MDR2400 RFU Orion2410i RFU MDR5800 RFU Orion5810i RFU Orion2450 RFU Orion5850 RFU Older versions (up to version 3.08) of the firmware are only suitable for MDR Digital Indoor Units and are identified by the following filename: IDU_X_XX.CVF, WHERE THE X_XX IS THE NUMERIC VERSION NUMBER. Newer firmware versions (version 4 upwards) are identified by the following filename: abcddeeefghi_x_xx.cvf, where x_xx is the numeric version number of the firmware. The other fields in the name has the following meaning: 862-01881 Issue 13 Page 127 Orion and MDR Digital Radios a: b: c: dd: eee: f: ghi: M, O, P = Digital Indoor Unit PCB (MDR, Orion10/25, Orion 50 respectively) C=100 X=10 Ethernet to RFU (or - if both are supported) 2=v2 framing 3=v3 framing structure (3 is programmable, 2 is used on MDR) tt = 04=4 tribs 08=8 tribs E3, T3, etc 2.4 5.8 if it's specifically limited, not in name if not used T or E for T1/E1 if it's specifically limited, not in name if not used Reserved, not in number if not used Examples: oc308_4_04.cvf = Orion 100M v3 framing 8 tribs (Normal 8e1) ox204_4_04.cvf = Orion 10M v2 framing 4 tribs (CCK-compatible 8e1) mx204_4_09.cvf = MDR type DIU firmware. 862-01881 Issue 13 Page 128 Orion and MDR Digital Radios E Appendix: FIXED Antennas The table below identifies the distances where the 1mW/cm exposure limits may be exceeded during continuous transmission using the proposed fixed antennas. E.1 MDR5800 Manufacturer Gabriel Gabriel MTI Type Dish Flat panel Flat panel Model Gain (dBi) Numeric gain Peak Power (mW) Calculated Distance (m) Minimum RF Exposure Separation Distance (m) SSP2 52B DFPD1-52 MT-20004 29.0 23.9 28.0 794.3 245.5 631.0 239.9 239.9 239.9 1.2 0.7 1.1 Model Gain (dBi) Numeric gain Peak Power (mW) Calculated Distance (m) Minimum RF Exposure Separation Distance (m) SSP2 52B 29.0 794.3 239.9 1.2 Model Gain (dBi) Numeric gain Peak Power (mW) Calculated Distance (m) Minimum RF Exposure Separation Distance (m) SSP2 52B MT-20004 29.0 28.0 794.3 631.0 239.9 239.9 1.2 1.1 E.2 Orion5810i Manufacturer Gabriel Type Dish E.3 Orion5850 Manufacturer Gabriel MTI Type Dish Flat panel E.4 MDR2400, Orion2410i and Orion2450 Manufacturer Gabriel Type Parabolic Model Gain (dBi) Numeric gain Peak Power (mW) Calculated Distance (m) Minimum RF Exposure Separation Distance (m) SSG4-23 26.7 467.7 63 0.5 WARNING: It is the responsibility of the professional installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only these antenna configurations shown in the table above are used. The use of any antenna other than those listed is expressly forbidden in accordance to FCC rules CFR47 part 15.204. FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment when installed as directed. This equipment should be installed and operated with fix-mounted antennas that are installed with a minimum separation distance of 2 meters (6.6 ft) or more from all persons during normal operation to satisfy RF exposure requirements. 862-01881 Issue 13 Page 129 Orion and MDR Digital Radios F Appendix: Useful web links The URL http://www.plesseyinc.com/ provides information on current products as well as some FAQ. For any other questions, the latest firmware or software, contact your local distributor, customer support on the above web site or customer support at mdrsupport@tellumat.com. 862-01881 Issue 13 Page 130 Orion and MDR Digital Radios G Appendix: MDR / Orion SCALABLE 1-to-4/8 E/T1 / 10 BaseT Ethernet functionality Depending on the radio model and RFU configuration, the MDR / Orion radio can simultaneously support 1 to 8 E1 or T1 tributary channels, with the balance of the available user BW made up by Ethernet packet data, up to a maximum aggregate Ethernet throughput no greater than 9.5 Mbps (Combined up- and downstream throughput). The unidirectional Ethernet throughput of the radios is limited to a maximum of 8 Mbps, which decreases as more tributary channels are activated. 862-01881 Issue 13 Page 131 Orion and MDR Digital Radios H Appendix: MDR / Orion FTP Firmware Upload Firmware can be uploaded to MDR and Orion DIUs using FTP uploads as well as by using the "CVF Loader" or NMS software, available on the software CD or from the distributor. Note the following: Username : anonymous Password : guest The relevant MIB info is in the "mdrmteConfiguration" GROUP 1.3.6.1.4.1.1316.1.1.1.2.5 mdrmteFirmware 1.3.6.1.4.1.1316.1.1.1.2.5.1 mdrmteFTPServerStatus 1.3.6.1.4.1.1316.1.1.1.2.5.2 mdrmteFlashNewFirmware By Default for mdrmteFTPServerStatus : the Digital Indoor Unit FTP server is active By Default for mdrmteFlashNewFirmware : the upgrade is immediate (it can also be timed) We recommend that the user ALWAYS verify that the new version has indeed been uploaded and is being used by the DIU. In this case one checks the following element: 1.3.6.1.4.1.1316.1.1.1.2.4.3 mdrmteIUFirmwareVersion This OID (object ID) is part of: 1.3.6.1.4.1.1316.1.1.1.2.4 mdrmteGeneral, part of the "mdrmteConfiguration" GROUP When updating the Digital Indoor Unit firmware by means of FTP, please note that the choice of IP address is very important. You must always choose the IP address of the interface "closest" to you. In other words if you are using Ethernet to connect, then use the IP address of the Ethernet Interface. NOTE If you are updating the firmware on the remote unit, use the IP address of the "overhead" PPP link - NOT the Ethernet interface of the remote unit. For example use 192.168.4.3 when uploading to the far side and using the bridging configuration. If by mistake you use the wrong address, you will create a "half-established" FTP session, and NO FURTHER SESSIONS will be permitted until the session times out after some minutes. 862-01881 Issue 13 Page 132 Orion and MDR Digital Radios Setup for Full Duplex mode on the MDR: Max Transfer Rate Follow the steps outlined below to setup the MDR radio in Full Duplex mode: • Upload the radio Firmware by following the aforementioned procedure. Full duplex Ethernet operation is supported from version 2 of the firmware. • Setup default configuration of the radio to the required configuration. Refer to Section 2.3.4 for a description of the different default configurations. • Ensure that the PCB revision of the DIU is issue_2_mod_a(3) by reading the following MIB element: 1.3.6.1.4.1.1316.1.1.1.2.4.15 mdrmteIndoorUnitPCBrevision. If the PCB revision is issue_2(2) the radio hardware does not support Full Duplex Ethernet mode. • Disable all tributary channels to make the maximum user bandwidth available for Ethernet traffic. • Enable Full Duplex mode via the MIB using element: 1.3.6.1.4.1.1316.1.1.1.4.16 mdrmteEthernetFullDuplex. • Set the data rate to T1 if required using MIB element: 1.3.6.1.4.1.1316.1.1.1.2.1.1 mdrmteDataRate. 862-01881 Issue 13 Page 133 Orion and MDR Digital Radios I Appendix: Getting started guide I.1 Checklist for Bench Testing (without a PC) Chec You will need the following: 1 MDR / Orion User Manual (Issue 11) 2 Digital Indoor Units 2 RF Units 1 or 2 Power supplies 2 Digital Indoor Unit power cables 2 Indoor to RF Unit power cables 2 Indoor to Outdoor RJ45 Data cables N-type male to N-type male (6 GHz) RF cable 60 - 90 dB of N-type attenuators 10 2.5 mm Allen Key 11 3 mm terminal screwdriver Additional Information 1 low and 1 high band - see L/H stamp near serial number User Manual par. 4.2.3 and 8.4 User Manual par. 4.2.3 Specifications - User Manual par. 8.5.10 Connections - User Manual par. 4.4.1 Type and connection - User Manual par. 4.3.1 Note Max input is -30 dBm, default output power is +24 dBm Required to open the connector lid on the RF Unit. Required to connect the power cables Recommended items: 12 13 T1 or E1 BER Tester T1/E1 Payload cable 14 Payload Loopback Connector User Manual par. 4.2.4, 4.2.5, 4.2.6 User Manual par. 4.2.4, 4.2.5, 4.2.6 You will need to know: 15 How to use the reset button: When you press and hold down the reset button on the front panel with a suitable tool,the 3 LEDs on the front panel will change state depending on the duration that the button is held down for: Count the number of state changes and let go of the reset button when the desired count is reached: It starts off with one green LED in the right most position, "moving" to the left: Numb er 862-01881 Issue 13 Left (System) off Middle(Payloa d) off Right (RF Link) Green Page 134 Orion and MDR Digital Radios off Green off Green off off Then an Orange LED "moving" from right to left (for 4-6), then Red, then Green again etc. NOTE If you accidentally overshoot, keep on holding the reset button until all the LEDs eventually go off. Then release the button and try again. See User Manual - par. 2.3.4 for more detail. 16 How to interpret the status of the LEDs: Interpreting Rear Panel LED (Front Panel on Orion DIU) DIU/RFU Link LED - OFF: No communication between Indoor and RF Units Check cables between Digital Indoor Unit and RF Unit Interpreting Front Panel LEDs Continually Lit LEDs LED COLOR I.2 Interpretation System RED There is a problem with the communication to the RF Unit RF Link RED Continually running bit errors on tributaries Payload RED System RF Link Payload The is no Payload signal present (LOS) on one or more tributaries ORANGE There is a problem with the communication to the RF Unit ORANGE FEC is correcting errors - no problem ORANGE The incoming payload signal is AIS I.3 Action Check cables between Digital Indoor Unit and RF Unit If System LEDs are green then check RF Units Check connections to the BER Tester Check cables between Digital Indoor Unit and RF Unit No problem unless the LED stays orange Check BER tester Flashing/Blinking LEDs A blinking LED indicates that a particular error condition from the table above (same colour coding) occurred at some time in the past. You can clear this memory of past errors by applying a "1 LED"-reset. 862-01881 Issue 13 Page 135 Orion and MDR Digital Radios I.4 One Page Set-up for T1/E1 Bench Test (without a PC) 1. PREPARATION: Complete the attached check list This section applies to the MDR and Orion radio series with the only difference being the location of the interface connectors on the MDR and Orion DIUs. Complete the attached checklist (above section) to ensure that you have the required equipment and information to continue. Do not continue until you have read the checklist in the above section! 2. CONNECT AS SHOWN, THEN SWITCH POWER ON RF Attenuator Outdoor Unit Data Power DC Power Supply Far Side Indoor Unit Attenuator Loopback Connector RF O utdoor Unit Data Power DC Power Supply Near Side Indoor Unit BER Tester 862-01881 Issue 13 Page 136 Orion and MDR Digital Radios 3. CONFIGURE USING THE RESET BUTTON Be sure that you know how to use the reset button before continuing! See note "How to use the reset button" on the checklist, above section. Configure your payload type to T1 or E1: For E1: For T1: Do a 12-reset on both Digital Indoor Units Do a 13-reset on both Digital Indoor Units Configure Near and Far side Digital Indoor Units: For Near: Do an 8-reset on the Digital Indoor Unit you would like as the "Near" side unit Note that this clears all stored parameters to factory defaults For Far: Do a 7-reset on the Digital Indoor Unit you would like as the "Far" side unit Note that this clears all stored parameters to factory defaults 4. CLEAR ERRORS Apply a 1-reset to Clear the Historical errors on the Front Panel LEDs See note "Interpreting LED Status" on the checklist Apply a 2-reset to Clear the Event Log in the Digital Indoor Unit This is required if you wish to view the Event Log using a PC. Reset your BER Tester. 5. MONITOR STATUS Be sure that you know how to interpret the status of the LEDs before continuing! See note "Interpreting LED Status" on the checklist If all is well, then: BER Tester should run with no errors All 3 Front Panel LEDs should be green. (The RF Link LED may flash orange without the need to worry.) If you have not connected a BER Tester, then the Payload LED will be Red, indicating LOS i.e. no payload signal. NOTE Make sure to deactivate all unused tribs to ensure that the Payload LED stays GREEN for the tribs used. That is: if only two tribs are used, but all four are active, a RED Payload LED will be indicated as the two unused tribs have LOS. Deactivating the two unused tribs through the NMS / GUI, will result in the Payload LED only indicating information for two active tribs – i.e. are there a valid signals on the two tribs, regardless of the two other, unused tribs. 862-01881 Issue 13 Page 137 Orion and MDR Digital Radios J APPENDIX: 1+1 PROTECTION SYSTEM OPERATION J.1 J.1.1 Introduction System Description When a single radio link is used to convey user data, any number of unexpected events may cause the link to fail resulting in user data being lost. This would require immediate corrective actions from the network operator responsible for maintaining the radio link. Since such a failure may occur at any time and possibly at a remote location, corrective actions may be very costly, both in terms of downtime and human resources. Common reasons for radio links to fail are: • Signal fading on the radio link • The presence of strong in-band interference • Equipment failure One possible solution to this problem is to install a second redundant radio link that can automatically take over the function of the primary radio link. This not only reduces the downtime of the link, but also provides the network operator with the opportunity to repair the faulty link at a convenient time. This document describes the one-plus-one redundancy system that can be used with the radio products of Plessey BBW. Radio systems that are currently supported by the system are: • MDR2400-SR • MDR5800-SR • Orion 2410-SRi • Orion 5810-SRi • Orion 5825-SR The remainder of this document is aimed at giving a detailed technical description of the redundancy system and the installation thereof. J.2 J.2.1 Technical Description System Overview The functionality required to establish a protected radio link is already built into the MDR- and Orion-type Software Radios. This implies that the user can set up a protected radio link by interconnecting the equipment for two parallel radio links through a 1U protection panel and a dedicated communications cable. Each Digital Indoor Unit in a protected radio system continuously monitors the status of the radio link it uses, as well as the radio link provided through the redundant system running in parallel. Digital Indoor Units forming part of a redundant link at each end of the radio link share status information through a cable connecting the two Auxiliary ports of the Digital Indoor Units. 862-01881 Issue 13 Page 138 Orion and MDR Digital Radios Only the tributary payload data channels are protected by the redundant link i.e. there is no protection for Ethernet data. Tributary payload data is split and combined between links through a 1U protection panel that connects to the user network equipment as well as the two Digital Indoor Units used at each end of the redundant link. Although both radio links are functioning continuously, only one of the Digital Indoor Units is actively driving the tributary channels of the user network at any given time. Each Digital Indoor Unit continuously monitors the level of the Packet Error Ratio (PER) for the radio link on which it is receiving user data. When the PER exceeds a predefined ratio of 10 consecutive seconds, the Digital Indoor Unit driving the tributary channels of the user network will signal the redundant Digital Indoor Unit to take over processing the data it receives over the radio link. The value of the PER threshold is configurable and can be changed through the Orion NMS if required. The default value is set at 30%. There is no notion of a primary and secondary link in this redundancy system. The first link to be configured successfully will start driving the tributary payload channels. Switch over will only take place when the aforementioned condition occurs. In the event where the link to which the data was switched over fails at a later stage, the system will attempt to switch the data back to the original link. NOTE 1 A situation can arise where the up- and downstream user tributary data is carried by separate radio links, i.e. link A carries the upstream data, and link B carries the downstream data. NOTE 2 Due to the architecture of the redundancy system, the process of switching over from one link to another is not hitless and user tributary data will be lost for a few seconds (< 10) J.2.2 System Configuration The block diagram in Figure 15 illustrates a typical redundancy system configuration. Note that this system is managed over an Ethernet LAN, where the two local Digital Indoor Units are connected to the LAN using a hub. It is important to note that the IP addresses for each Digital Indoor Unit should be unique. It is however possible to configure each link in the redundant system separately through the Element-Manager port of each local Digital Indoor Unit, in which case it is not necessary to assign unique IP addresses to the Digital Indoor Units. The block diagram in Figure 15 also clearly illustrates the following important interfaces: • DIU A to DIU B connection through the respective Auxiliary ports of the four Digital Indoor Units • The Protection Panel interfaces on each side of the link that combines and splits the tributary payload channels between the two radio links • The single user network interfaces provided by the Protection Panel • The two radio links that provide the redundancy required for user data protection 862-01881 Issue 13 Page 139 Orion and MDR Digital Radios One-Plus-One Redundancy System Tributries Tributries Network Port IP Addr 192.168.1.2 IDU 1 A Network Port IP Addr 192.168.1.3 ODU RF Link A ODU IDU 2 A AUX Port Cross Connect IDU 1 B Protection Panel Splitter/Combiner Protection Panel Splitter/Combiner Ethernet AUX Port Cross Connect ODU RF Link B ODU Network Port IP Addr Ethernet 192.168.1.4 IDU 2 B Network Port IP Addr 192.168.1.5 HUB Config PC Figure 15: Block diagram of a typical redundancy protected system where the radio links are managed through an Ethernet network. J.2.2.1 1U Protection Panel There are two types of protection panels: a four and an eight tributary channel panel. They operate in the same way and perform the signal splitting and combination functions for the tributary channels taking part in the redundancy protected radio system. Note from Table 15: Protection Kit connector interfaces. that the Protection Kit is currently only provided in 110-ohm as a compromise to make provision for E1 and T1 mode. Table 15: Protection Kit connector interfaces. Description Connector Impedance 2xDB-25 or 8xRJ-48 110 ohm 2x2xDB-25 110 ohm DB-25 or 4xRJ-48 110 ohm 2xDB-25 110 ohm Orion Protection Panel Payload Network Interface Digital Indoor Unit Interface Orion Protection Panel Payload Network Interface Digital Indoor Unit Interface The cables required to connect the Patch Panel to the two Digital Indoor Units are provided with the Patch Panel. The DB-25 pinouts used for each DB-25 connector on 862-01881 Issue 13 Page 140 Orion and MDR Digital Radios the patch panel are exactly the same as that of the MDR and Orion Digital Indoor Units respectively. J.2.2.2 Auxiliary port communication The two Digital Indoor Units on each side of the radio link share status information through the two relay outputs and OPTO inputs on the Auxiliary (AUX) port of each Digital Indoor Unit. Information shared by each of these: J.3 • Indication if the Digital Indoor Unit is currently driving the tributary channels on the user network • The current Frame Lock status detected by the Digital Indoor Unit for the radio link it is using System functional description Each Digital Indoor Unit taking part in a protected radio link continuously monitors the PER of the radio link it is receiving tributary data over. If the PER for the link increases above the Sever Error Margin for more than 10 consecutive seconds, the Digital Indoor Unit will request the second Digital Indoor Unit to take over the driving of the tributary channels if the second Digital Indoor Unit sees a frame lock. Once the second Digital Indoor Unit has started driving the tributary channels, the first Digital Indoor Unit becomes the redundant link. The flow diagram for the algorithm that governs the protection switch-over process in each Digital Indoor Unit is illustrated in Figure 16. Reset Is IU driving the Tribs Reset Timer NO NO Is Redundant IU driving Tribs YES NO PER > Threshold IU has frame lock YES YES Timer >= 10sec Start Driving Tribs & Signal Redundant IU YES NO YES Stop Driving Tribs & Signal Redundant IU YES Redundant IU has frame lock Figure 16: Redundant system switch-over algorithm. 862-01881 Issue 13 Page 141 Orion and MDR Digital Radios J.4 J.4.1 Installation Hardware Installation The following list of equipment is required to set up a protected radio link: • Four MDR / Orion Digital Indoor Units • Four MDR / Orion RF Units • Two MDR / Orion Protection Kit 1U panels (Supplied with protection kit) • Four / Eight DIU interface loom cables (Supplied with protection kit) • Tributary channel interface cables to connect to the user network • Two DIU auxiliary communications cables (Supplied with protection kit) • Standard tools and cabling required to set up a MDR / Orion radio link Illustrations of the Protection Kits can be seen in Figure 17and Figure 18. Note from the drawings that the Orion Protection Kit offers the ability to protect eight E1/T1 tributary channels. Thus, the latter could be used with either the MDR or Orion radios. Follow the steps below at each site to interconnect and set up the protected radio systems: • Install each DIU-RFU system as described in the MDR / Orion User Manual • Install the four / eight tributary channel Protection Kit panel in the rack mount • Connect tributary paths A and B on the Protection Kit panel to the two installed Digital Indoor Units using the provided DB-25 interface cables • Link the two Digital Indoor Unit auxiliary ports of the Digital Indoor Units through the DIU auxiliary communications cable • Switch on the two units and configure the radios as explained in Section J.4.2 • Connect the tributary interface of the Protection Kit panel to the user network through the preferred interface (DB-25 / RJ48) NOTE Be sure to acquire the correction protection kit that matches the Digital Indoor Unit type you intend to use. Figure 17: MDR Protection Kit front panel. 862-01881 Issue 13 Page 142 Orion and MDR Digital Radios Figure 18: Orion Protection Kit front panel. Figure 19: Tributary channel interface cable used to connect Protection Kit Paths A & B to the two Digital Indoor Units. DIU auxiliary communications cables are supplied with the Protection Kit and are used to connect the auxiliary ports of the two Digital Indoor Units according to Table 16. The system diagram when using the two radio pairs in bridging mode is shown in Figure 15. Table 16: Auxiliary Port cross connection. Radio 1A Pin No 12 13 14 15 J.4.2 Radio 1B Pin No 12 13 14 15 Radio Software Configuration Two MIB elements are used to configure the radios taking part in the protected radio link. These MIB elements can be set using any SNMP element manager application, or through the Orion NMS application. Please refer to the following user manuals for details on using the above applications: • MDR / Orion – SR user manual • Orion NMS HTML user manual • 3 party user manual (If a 3 party SNMP element manager / MIB browser is used. rd rd Set the following MIB element in all IDUs taking part in the protected radio link to 1 (Yes). mdrmteOnePlusOne (OID: 1.3.6.1.4.1.1316.1.1.1.2.4.17, Parent: mdrmteGeneral) 862-01881 Issue 13 Page 143 Orion and MDR Digital Radios The MIB element controlling the switch-over threshold, mdrmteSevereErrorMargin (OID: 1.3.6.1.4.1.1316.1.1.1.2.2.18, Parent: mdrmteRFLinkConf), is set to 30% by default. This value is a percentage and represents the switch-over threshold for the Packet Error Ratio (PER). When the PER exceeds 30%, the switch-over will occur. The value of this MIB element can be adjusted to meet the exact user requirements. It is advisable to set the switch-over threshold on all Digital Indoor Units to the same value. J.5 System Verification Since most of the functionality of the protected system is hidden from the user, it may be difficult to monitor the status at times. It can however be determined by monitoring the MIB elements listed below. The status of the protected link can also be monitored through the Orion NMS. Please refer to the Orion NMS user manual for more information on this option. • Name: mdrmteOnePlusOne – shows if the protected mode is active (OID: 1.3.6.1.4.1.1316.1.1.1.2.4.17, Parent: mdrmteGeneral) • Name: mdrmtePayloadDrive – shows if the Digital Indoor Unit is driving the tributary channels of the user network (OID: 1.3.6.1.4.1.1316.1.1.1.3.1.5, Parent: mdrmteInfo) • Name: mdrmteLock – shows if frame lock is present (OID: 1.3.6.1.4.1.1316.1.1.1.3.1.6, Parent: mdrmteInfo) • Name: mdrmtePeerPayloadDrive – shows if the Auxiliary port connected Digital Indoor Unit (Peer) is driving the tributary channels. This element is the inverse (opposite) of mdrmtePayloadDrive (OID: 1.3.6.1.4.1.1316.1.1.1.3.1.7, Parent: mdrmteInfo) • Name: mdrmtePeerLock - shows if the Auxiliary port connected Digital Indoor Unit (Peer) has frame lock (OID: 1.3.6.1.4.1.1316.1.1.1.3.1.8, Parent: mdrmteInfo) • Name: mdrmteSevereErrorMargin – the threshold percentage value for link unavailable to switch over (OID: 1.3.6.1.4.1.1316.1.1.1.2.2.18, Parent: mdrmteRFLinkConf) • Name: mdrmteAveragePER – average Packet Error Ratio (OID: 1.3.6.1.4.1.1316.1.1.1.1.2.15, Parent: mdrmteRFLinkPerf) • Name: mdrmteCurrentPER – real time Packet Error Ratio. For example a PER of 1e-1 (10%) corresponds to a SevereErrorMargin value of 10. The Current PER has to exceed the Severe Error Margin for 10 seconds continuously for the link to become unavailable and switch over to its peer Digital Indoor Unit. (OID: 1.3.6.1.4.1.1316.1.1.1.1.2.3, Parent: mdrmteRFLinkPerf) 862-01881 Issue 13 Page 144 Orion and MDR Digital Radios K APPENDIX: Indoor RF Units Orion2410i, Orion5810i K.1 Description The Indoor RF Units are functionally similar to the MDR2400 and MDR5800 RF Units referred to in the body of this manual. All connections and functional indicators are on the front panel. Combinations: Orion2410-SRi = Orion10 (Digital Indoor Unit) + Orion2410i (Indoor RFU) Orion5810-SRi = Orion10 (Digital Indoor Unit) + Orion5810i (Indoor RFU) K.2 Steps to install the Indoor RF Unit: 1. Install the Indoor RF Unit similar to description in 4.2.2 not forgetting earthing. 2. Install the system antenna with reference to Section 5. The RSSI BNC connector is on the front panel. 3. Connect the RF cable or wave guide outer conductor to the pole lightning earth electrically before it enters the equipment shelter. 4. Connect the type-N RF output connector to the system antenna through an inline lightning protection unit in areas with lightning activity. 5. Cover the connectors using an ultra violet protective, self-vulcanising tape. CAUTION – ENSURE THAT THE POLE IS EARTHED FOR LIGHTNING PROTECTION. 862-01881 Issue 13 Page 145 Orion and MDR Digital Radios K.3 RF Connection 1. The RF port is an N-type female connector on the front panel. 2. The N-Type connector is used to connect to the antenna, typically using coaxial transmission line or flexible wave guide via a launch/N-type adaptor. 3. Elliptical wave guide is recommended for longer feeder runs to minimize losses. 4. Also refer to 4.3.1. K.4 Interconnection Cable Installation Refer to 4.4 and follow the steps to install the interconnection cables between Indoor (Digital) Unit and Indoor (RF) Unit. All connections to the Indoor (Digital) Unit are on the front panel. 862-01881 Issue 13 Page 146 Orion and MDR Digital Radios Index Add Modem Windows 2000 and XP · 97 auxiliary port · 36 installation before radio installation · 31 commissioning record · 46 outdoor unit mechanical · 38 recommended procedure · 31 cables IU to OU connections · 39 IU to OU (RJ45 + power) cable type · 10, 60 recommended · 60 RF · 38 commissioning · See installation configuration button · See reset button customer support · See web links dial-up networking add Windows 95/98 · 95 Windows NT · 88, 97 LED reset · See reset button LEDs interpreting on front panel · 21 modem add Windows 95/98 · 93 Windows NT · 83 modulation different types MDR2400 · 53 MDR5800 · 53 Orion 5850 · 17 element manager dial-up connection · See modem PPP RS232 connection · See modem outdoor unit connection to IU · See cables, IU to OU (RJ45 + power) firmware compatibility · 126 upload ftp · 132 fuse · 25 payload (T1/E1) BNC · 36 DB25 · 35 RJ45 · 36 power IU DC connector · 25, 34 IU DC requirement · 52 getting started · 134 reset button · 22 862-01881 Issue 13 Page 147 Orion and MDR Digital Radios 862-01881 Issue 13 web links · 130 www · See web links Page 148
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2003:12:22 11:40:02-07:00 Create Date : 2003:12:22 11:39:38-07:00 Title : CERTIFICATE OF COMPLIANCE Author : Systems Administrator Creator : Microsoft Word 10.0 Producer : Acrobat Distiller 4.05 for Windows Page Count : 149EXIF Metadata provided by EXIF.tools