STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 125 of 500 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 126 of 500 
 9.4.3.  800MHz Line Amplifier (Ext. Amp.) (55-165401) 
800MHz Line Amplifier (Ext. Amp.) (55-165401) list of major components 
 section Component 
Part  Component Part Description  Qty. Per 
Assembly
9.4.3.3. 02-007206 Bandpass Filter  4 
9.4.3.4. 07-015105 Wideband Asymmetric Coupler  2 
9.4.3.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 
9.4.3.6. 11-006702 Low Noise Amplifier  1 
9.4.3.7. 12-018002K Power Amplifier  1 
9.4.3.8. 12-021901 Low Power Amplifier  2 
17-001109  AGC Detector Assembly (Logarithmic)  1 
17-001117  AGC Detector Assembly   1 
9.4.3.9. 
17-001201  AGC Attenuator Assembly   2 
9.4.3.10.  80-008901  12V (Single) Relay Board  1 
9.4.3.11.  94-100004  Dual Diode Assembly  1 
9.4.3.12. 96-200047  DC/DC Converter  1 
9.4.3.13.  96-300052  12V Switch-Mode PSU  1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 127 of 500 
 9.4.3.1.  800MHz Line Amplifier (Ext. Amp.) (55-165401) outline drawing 
Drawing number 55-1654101 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 128 of 500 
 9.4.3.2.  800MHz Line Amplifier (Ext. Amp.) (55-165401) system diagram  
Drawing number 55-165481 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 129 of 500 
 9.4.3.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 9.4.3.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 130 of 500 
 9.4.3.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the 
four miniature toggle switches on the top of each unit. Each switch is clearly marked with the 
attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are 
designed to maintain an accurate 50Ω impedance over their operating frequency at both input and 
output. 
10-000901 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-15dB 
Attenuation Steps 1, 2, 4 and 8dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range  DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
 9.4.3.6.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800 – 1000MHz 
Bandwidth <200MHz 
Gain 29dB (typical) 
1dB Compression point 20dBm 
OIP3 33dBm 
Input/Output return loss >18dB 
Noise figure 1.3dB (typical) 
Power consumption 180mA @ 24V DC 
Supply voltage 10-24V DC 
Connectors SMA female 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
Size 90 x 55 x 30.2mm 
Weight 290gms (approximately) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 131 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 
 9.4.3.7.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 132 of 500 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 9.4.3.8.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 133 of 500 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 9.4.3.9.  Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz Line Amplifier (Ext. Amp.) (55-165401); 17-001117 and 17-001201 
are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 
800MHz Line Amplifier (Ext. Amp.) (55-165401) is fitted with two differing types of Automatic Gain 
Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-
001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the 
downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the downlink 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 134 of 500 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 9.4.3.10. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. The relay is provided with polarity protection diodes and diodes for 
suppressing the transients caused by "flywheel effect" which can destroy switching transistors or 
induce spikes on neighbouring circuits. It’s common use is to amalgamate all the alarm signals into 
one, volts-free relay contact pair for the main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 135 of 500 
 9.4.3.11. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 
 9.4.3.12.  DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 9.4.3.12.  12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  
(absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 136 of 500 
10. UNIVERSITY STATION MASTER SITE 1 (80-330552-1) 
Rack C05-CR-06 
55-165601 
55-165602 
55-165502 
98-800001 
98-700002 
55-165507 
55-165601 
55-165602 
55-165711 
University Station Master Site 1 (80-330552-1) list of major components 
section   Component Part Component Part Description  Qty. Per Assembly
10.4.1.  55-165502  800MHz FO HUB Splitter/Combiner  1 
10.4.2.  55-165507  Fibre Optic Splitter  1 
10.4.3.  55-165601  800MHz FO Hub Amplifier + Filters  2 
10.4.4.  55-165602  700MHz FO Hub Amplifier  2 
10.4.5.  55-165711  UNIVERSITY ST. SPLITTER 1  1 
10.4.6.  98-700002  Optical A/B Switch FC/APC  1 
10.4.7.  98-800001  F/O Link Subsystem  1 
800MHz FO Hub Amplifier (55-165601)  

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 137 of 500 
 10.1. University Station Master Site 1 (80-330552-1) Rack elevation 
Drawing number 80-330552 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 138 of 500 
 10.2. University Station Master Site 1 (80-330552-1) system diagram 
Drawing number 80-330582-1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 139 of 500 
 10.3. University Station Master Site 1 (80-330552-1) Alarm Wiring Diagram 
Drawing number 80-330522-1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 140 of 500 
 10.4  University Station Master Site 1 (80-330552-1) Major Components 
 10.4.1.  800MHz FO HUB Splitter/Combiner (55-165502) 
800MHz FO HUB SPLITTER/COMB (55-165502) List of major components 
 section  Component 
Part  Component Part Description  Qty. Per 
Assembly
10.4.1.3.  05-002602  900MHZ SPLITTER/COMBINER, 20W  2 
10.4.1.4.  05-003302  Four Way Splitter/Combiner  2 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 141 of 500 
 10.4.1.1.  800MHz FO HUB SPLITTER/COMB (55-165502) Outline Drawing 
Drawing number 55-1655102 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 142 of 500 
 10.4.1.2.  800MHz FO HUB SPLITTER/COMB (55-165502) System Diagram 
Drawing number 55-165582 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 143 of 500 
 10.4.1.3. 900MHz Splitter/Combiner (05-002602) 
The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an 
appropriate 50Ω load. 
Being passive devices, the splitters should have an extremely long operational life and require no 
maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module 
rather than attempt repair or re-tuning. 
05-002602 Specification 
 PARAMETER  SPECIFICATION 
Narrowband: 815 – 960MHz Frequency 
range:  Broadband: 800 – 1200MHz 
Narrowband: 145MHz 
Bandwidth:  Broadband: 400MHz 
Input ports: 1 
Output ports: 2 
Narrowband: 3.3dB 
Insertion loss:  Broadband: 3.5dB 
Return loss input & output: 1.3:1 
Impedance: 50Ω 
Narrowband: >20dB 
Isolation:  Broadband: >18dB 
MTFB: >180,000 hours 
Splitting: 20Watts 
Power rating:  Combining: 0.5Watt 
Connectors: SMA female 
Weight: 200g (approximately) 
Size: 54 x 44 x 21mm  
 10.4.1.4.  Four Way Splitter/Combiner (05-003302) 
The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an 
appropriate 50Ω load. 
Four Way Splitter (05-003302) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 700-980MHz 
Bandwidth 180MHz 
Rejection >14dB 
Insertion loss <7.0dB (in band) 
Connectors N type, female 
Weight <1.5kg 
operational -20%C to +60%C Temperature 
range  storage -40%C to +70%C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 144 of 500 
 10.4.2.  Fibre Optic Splitter (55-165507) 
Fibre Optic Splitter (55-165507) is a 1U rack mount tray containing an optical splitter/coupler 
Fibre Optic Splitter (55-165507) List of Major Sub Components 
 Component 
Part  Component Part Description  Qty. Per 
Assembly 
98-100001  Single Mode Optical Splitter/Coupler  1 
 10.4.2.1.  Single Mode Optical Splitter/Coupler (98-100001) 
Single Mode Optical Splitter/Couplers are used whenever it is necessary to split or combine outputs 
from optical transmitters or inputs to receivers. Operators should be aware that a small insertion loss 
(typically 3-4dB) is common with these type of couplers.  
Single Mode Optical Splitter/Coupler (98-100001) It is an O.E.M unit featuring almost negligible 
insertion loss to the F/O signal. Extreme caution should be exercised when handling these devices. 
Special attention should be shown to the connectors; repair of a broken Splitter/Coupler is not 
possible; replacement is the only option. 
In the Fibre Optic Splitter (55-165507) in University Station Master Site 1 (80-330552-1), Single Mode 
Optical Splitter/Coupler (98-100001) is used to split the optical signal from the FO TX module in F/O 
Link Subsystem (98-700001) into two equal paths. 
 10.4.3.  800MHz FO Hub Amplifier + Filters (55-165601) 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
10.4.3.3.  02-007206  900MHZ 8POLE 25MHz+ B/W "SMA"  6 
10.4.3.4.  07-015105  ASYMMETRIC CPLR 30dB 800-2500MHz GA  3 
10.4.3.5.  10-000701  SW ATT 0-30dB 0.25W SMA F  2 
10.4.3.6.  11-005902K 900MHz LOW NOISE AMP WITH RELAY KIT  1 
10.4.3.7.  11-006702K 800-1000MHz LNA 29dB (cw RELAY) KIT  2 
10.4.3.8.  12-018002K PA 800-960MHz 20W CLASS A KIT  1 
10.4.3.9.  12-021901  Low Power Amplifier  2 
17-001109*  AGC Detector Assembly (Logarithmic)  1 
17-001117*  AGC Detector Assembly   1 
10.4.3.10. 
17-001201*  AGC Attenuator Assembly   2 
10.4.3.11.  20-001601  12V RELAY BOARD  1 
10.4.3.12.  80-008901  12V RELAY PCB ASSEMBLY  1 
10.4.3.13.  94-100004  STPS12045TV 60A DUAL DIODE  1 
10.4.3.14. 96-200047  DC/DC Converter  1 
10.4.3.15.  96-300052  JWS150-12/A PSU (COUTANT LAMBDA)  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz FO Hub Amplifier + Filters (55-165601); 17-001117 and 17-001201 
are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 145 of 500 
 10.4.3.1.  800MHz FO Hub Amplifier + Filters (55-165601) outline drawing 
drawing number 55-1656101 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 146 of 500 
 10.4.3.2.  800MHz FO Hub Amplifier + Filters (55-165601) system diagram  
drawing number 55-165681 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 147 of 500 
 10.4.3.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 10.4.3.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 148 of 500 
 10.4.3.5. Switched Attenuator 0.25Watt, 0 - 30dB (10-000701) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
Switched Attenuator 10-000701 provides attenuation from 0 to 30dB in 2 dB steps The attenuation is 
simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly 
marked with the attenuation it provides, and the total attenuation in line is the sum of the values 
switched in. They are designed to maintain an accurate 50Ω impedance over their operating 
frequency at both input and output. 
10-000701 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-30dB 
Attenuation Steps 2, 4, 8 and 16dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation  -20°C to +60°C Temperature 
range  storage  -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 149 of 500 
 10.4.3.6.  Low Noise Amplifier (11-005902) 
The Gallium-Arsenide low noise amplifier used in the unit is a double stage, solid-state low noise 
amplifier. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low 
noise over a very wide dynamic range. The active devices are very moderately rated to provide a long 
trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a 
failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm 
system which gives a volt-free relay contact type alarm that is easily integrated into any alarm system. 
There is a Current Fault Alarm Function, which indicates failure of each one or both RF transistors by 
a various alarm output options. The amplifier is housed in an aluminium case (Iridite NCP finish) with 
SMA connectors for the RF input/output and a 9way D-type for DC and alarm outputs.  
11-005902 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 960MHz * 
Bandwidth: <170MHz 
Gain: 19.5dB (typical) 
1dB compression point: 21dBm 
OIP3: 33dBm 
Input/output return loss: >20dB 
Noise figure: 1dB (typical) 
Power consumption: 190mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C Temperature 
range  storage: -40°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 0.28kg  *tuned to Customer's specification 
 LNA ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm relay O/P bad 
4  Alarm relay common 
5  Alarm relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 150 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
 10.4.3.7.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 151 of 500 
 10.4.3.8.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 152 of 500 
 10.4.3.9.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 153 of 500 
 10.4.3.10. Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz FO Hub Amplifier + Filters (55-165601); 17-001117 and 17-001201 
are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link 
800MHz FO Hub Amplifier + Filters (55-165601) is fitted with two differing types of Automatic Gain 
Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-
001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the 
downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the down link 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 154 of 500 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 10.4.3.11. 12V (Dual) Relay Board (20-001601) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw 
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the 
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on 
neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay 
contact pair for the main alarm system. 
20-001601 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage: 8 to 30V (floating earth) 
Alarm threshold: Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current: 1.0Amp 
Max. switch volts: 120Vdc/60VA 
Max. switch power: 24W/60VA 
Min. switch load: 10.0µA/10.0mV 
Relay isolation: 1.5kV 
Mechanical life: >2x107 operations 
Relay approval: BT type 56 
Connector details: Screw terminals 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 155 of 500 
 10.4.3.12. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. 
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
 10.4.3.13. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 156 of 500 
 10.4.3.14. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 10.4.3.15. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  (absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 157 of 500 
 10.4.4.  700MHz FO Hub Amplifier (55-165602) 
700MHz FO Hub Amplifier (55-165602) List of major components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
10.4.4.3.  02-007206  900MHZ 8POLE 25MHz+ B/W "SMA"  2 
10.4.4.4.  07-015105  ASYMMETRIC CPLR 30dB 800-2500MHz GA  2 
10.4.4.5.  10-000701  SW ATT 0-30dB 0.25W SMA F  2 
10.4.4.6.  11-005902  900MHz LOW NOISE AMP WITH RELAY KIT  1 
10.4.4.7.  11-006702  800-1000MHz LNA 29dB (cw RELAY) KIT  2 
10.4.4.8.  12-018002  PA 800-960MHz 20W CLASS A KIT  1 
10.4.4.9.  12-021901  Low Power Amplifier  2 
17-001109  AGC Detector Assembly (Logarithmic)  1 
17-001117  AGC Detector Assembly   1 
10.4.4.10. 
17-001201  AGC Attenuator Assembly   2 
10.4.4.11.  20-001601  12V RELAY BOARD  1 
10.4.4.12.  80-008901  12V RELAY PCB ASSEMBLY  1 
10.4.4.13.  94-100004  STPS12045TV 60A DUAL DIODE  1 
10.4.4.14. 96-200047  DC/DC Converter  1 
10.4.4.15.  96-300052  JWS150-12/A PSU (COUTANT LAMBDA)  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 700MHz FO Hub Amplifier (55-165602); 17-001117 and 17-001201 are paired 
for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 158 of 500 
 10.4.4.1.  700MHz FO Hub Amplifier (55-165602) Outline Drawing 
drawing number 55-1656102 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 159 of 500 
 10.4.4.2.  700MHz FO Hub Amplifier (55-165602) system diagram  
drawing number 55-165682 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 160 of 500 
 10.4.4.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 10.4.4.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 161 of 500 
 10.4.4.5. Switched Attenuator 0.25Watt, 0 - 30dB (10-000701) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
Switched Attenuator 10-000701 provides attenuation from 0 to 30dB in 2 dB steps The attenuation is 
simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly 
marked with the attenuation it provides, and the total attenuation in line is the sum of the values 
switched in. They are designed to maintain an accurate 50Ω impedance over their operating 
frequency at both input and output. 
10-000701 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-30dB 
Attenuation Steps 2, 4, 8 and 16dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation  -20°C to +60°C Temperature 
range  storage  -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 162 of 500 
 10.4.4.6.  Low Noise Amplifier (11-005902) 
The Gallium-Arsenide low noise amplifier used in the unit is a double stage, solid-state low noise 
amplifier. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low 
noise over a very wide dynamic range. The active devices are very moderately rated to provide a long 
trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a 
failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm 
system which gives a volt-free relay contact type alarm that is easily integrated into any alarm system. 
There is a Current Fault Alarm Function, which indicates failure of each one or both RF transistors by 
a various alarm output options. The amplifier is housed in an aluminium case (Iridite NCP finish) with 
SMA connectors for the RF input/output and a 9way D-type for DC and alarm outputs.  
11-005902 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 960MHz * 
Bandwidth: <170MHz 
Gain: 19.5dB (typical) 
1dB compression point: 21dBm 
OIP3: 33dBm 
Input/output return loss: >20dB 
Noise figure: 1dB (typical) 
Power consumption: 190mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C Temperature 
range  storage: -40°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 0.28kg  *tuned to Customer's specification 
 LNA ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm relay O/P bad 
4  Alarm relay common 
5  Alarm relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 163 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
 10.4.4.7.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 164 of 500 
 10.4.4.8.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 165 of 500 
 10.4.4.9.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 166 of 500 
 10.4.4.10. Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 700MHz FO Hub Amplifier (55-165602); 17-001117 and 17-001201 are paired 
for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 
700MHz FO Hub Amplifier (55-165602) is fitted with two differing types of Automatic Gain Control 
(AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is 
fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the downlink 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 167 of 500 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 10.4.4.11. 12V (Dual) Relay Board (20-001601) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw 
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the 
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on 
neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay 
contact pair for the main alarm system. 
20-001601 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage: 8 to 30V (floating earth) 
Alarm threshold: Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current: 1.0Amp 
Max. switch volts: 120Vdc/60VA 
Max. switch power: 24W/60VA 
Min. switch load: 10.0µA/10.0mV 
Relay isolation: 1.5kV 
Mechanical life: >2x107 operations 
Relay approval: BT type 56 
Connector details: Screw terminals 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 168 of 500 
 10.4.4.12. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. 
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
 10.4.4.13. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 
 10.4.4.14. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 169 of 500 
 10.4.4.15. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  (absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 170 of 500 
 10.4.5. University Station Splitter 1 (55-165711) 
University Station Splitter 1 (55-165711) list of major components 
 section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
10.4.5.3.  05-003005  3 PORT THC 900MHz  1 
10.4.5.4.  07-015102  ASYMMETRIC CPLR 10dB 800-2500MHz GA  4 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 171 of 500 
UNIVERSITY  STATION. SPLITTER 1
1:2 55-1657111
PB
17/10/2007
GD
17/10/2007
AA
24/09/07
OUTLINE DRAWING
PL
490.00
150.00
100.00
PORT JA2
PORT JA3
PORT JA1
PORT JC2
PORT JC1
PORT JB2
PORT JB1
PORT I1
PORT I2
5x HOLES SUITABLE FOR M5 FIXINGS
10.0
83.0
543
523.0
PRODUCT NUMBER : 55-165711
MATERIAL : CHASSIS - ALUMINIUM
FINISH : IRIDITE
CONNECTORS : 'N' TYPE SOCKET
180.0
AA ORIGINAL ISSUE PL
3.00
33.0
63.0
 10.4.5.1.  University Station Splitter 1 (55-165711) outline drawing 
drawing number 55-1657111 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 172 of 500 
 10.4.5.2.  University Station Splitter 1 (55-165711) system diagram 
drawing number 55-165791 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 173 of 500 
 10.4.5.3.  2-Way Splitter/Combiner (05-003005) 
This printed circuit based Splitter/Combiner is a device for accurately matching two or more RF 
signals to single or multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and 
ensuring that the VSWR and insertion losses are kept to a minimum. Any unused ports should be 
terminated with an appropriate 50Ω load. 
(05-003005) Specification 
 PARAMETER  SPECIFICATION 
Frequency Range 800 - 1000 MHz 
Input Ports 2 
Output Ports 1 
Insertion Loss <3.3 dB 
Isolation >18 dB 
VSWR 1.3:1 
Power Rating as a Splitter 50 Watts 
Power Rating as a Combiner 5 Watts 
Mechanical Wall mount case 
Weight <1.5kg 
RF Connectors ‘N’ female 
Dimensions 70mm x 63mm x 21mm 
(excludes connectors) 
operational -20%C to +60%C Temperature 
range:  storage -40%C to +70%C 
 10.4.5.4. Wideband Asymmetric Coupler (07-015102) 
The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 
10dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015102 Specification 
 PARAMETER  SPECIFICATION 
Frequency Range 800 - 2500 MHz 
Coupling Value 10 dB ± 1.0 dB 
Main Line Insertion Loss <1.6 dB 
VSWR 1.4:1 
Directivity >18 dB 
Power Rating 200 Watts 
RF Connectors ‘N’ female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 174 of 500 
 10.4.6.  Optical AB Switch FC/APC (98-700002)  
Optical A/B Switch FC/APC (98-700002) an O.E.M. sourced Fibre Optic relay supplied as a 1U rack 
mount tray. 98-700002 allows for the automatic switching between two optical inputs to provide a 
common optical output. Manual selection of the input is also possible via toggle switches on the front 
panel. 
98-700002 Specification  
 PARAMETER  SPECIFICATION 
Electrical Characteristics 
Power Supply Voltage  100 - 240 VAC 
Power Supply Frequency 50 - 60 Hz 
Optical Characteristics 
Operating Wavelength  1200 – 1610nm 
Optical Input Range  +20 dBm 
Optical Insertion Loss  2.0 dB 
Optical Trip Threshold/Meter Range  -35 - +20 dBm 
Optical Switch Speed  15ms 
Backreflection Tolerance  -50dB 
Environmental and Physical Characteristics 
Optical Connectors  FC/APC 
Operating Temp. Range  +10 to +40°C 
Storage Temp. Range  -40 to +80 °C   
Humidity  5 to 90 % RHNC 
Weight  2.2 kg (6 lbs) 
Dimensions  483 x 361 x 44mm (19.0 x 14.2 x 1.72 in.) 
 10.4.7.  F/O Link Subsystem (98-800001) 
F/O Link Subsystem (98-800001) is an O.E.M. sourced Optical Tranceiver package containing 
discreet TX and RX modules and supplied as a 1U rack mount tray  
 Parameter  Specification 
Optical Output Power 4 mW 
Wavelength, peak 1310 1550 nm  
Frequency Response, 50 to 2.2 GHz ± 1.5 dB 
Input and Output VSWR 1.5:1  
Link Gain (2) 0 dB 
Output Noise Floor (1) -137 dBm/Hz 
Input 3rd Order Intercept (1) 30 dBm 
Operating Temperature  −30 to +75°C 
Storage Temperature −40 to +85°C 
Maximum RF Input to Transmitter +20 dBm 
Maximum Optical Input to Receiver 6 mW 
A.C. Supply Voltage 90 – 265 VAC 
Dimensions 483 x 457 x 44mm (19.0 x 18 x 1.72 in.) 
(1) SFDR, Noise and IP3 specified with 5 dB optical loss. 
(2) Link Gain specified with 1 meter fiber. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 175 of 500 
11. UNIVERSITY STATION MASTER SITE 2 (80-330552-2) 
Rack C05-CR-07 
55-165601 
55-165602 
55-165603 
98-800001 
98-700002 
55-165507 
55-165601 
55-165602 
55-165711 
University Station Master Site 2 (80-330552-2) list of major components 
Section  Component 
Part  Component Part Description  Qty. Per Assembly
11.4.1.  55-165507  Fibre Optic Splitter  1 
11.4.2.  55-165601  800MHz FO HUB AMP + FILTERS  2 
11.4.3.  55-165602  700MHz FO Hub Amplifier  2 
11.4.4.  55-165603  700MHz FO HUB Splitter/Combiner  1 
11.4.5.  55-165712  UNIVERSITY ST. SPLITTER 2  1 
11.4.6.  98-700002  Optical A/B Switch FC/APC  1 
11.4.7.  98-800001  F/O Link Subsystem  1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 176 of 500 
 11.1. University Station Master Site 2 (80-330552-1) Rack elevation 
Drawing number 80-330552 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 177 of 500 
 11.2. University Station Master Site 2 (80-330552-1) system diagram 
Drawing number 80-330582-1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 178 of 500 
 11.3. University Station Master Site 2 (80-330552-1) Alarm Wiring Diagram 
Drawing number 80-330522-1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 179 of 500 
 11.4  University Station Master Site 2 (80-330552-1) Major Components 
 11.4.1.  Fibre Optic Splitter (55-165507) 
Fibre Optic Splitter (55-165507) is a 1U rack mount tray containing an optical splitter/coupler 
Fibre Optic Splitter (55-165507) List of Major Sub Components 
 Component 
Part  Component Part Description  Qty. Per 
Assembly 
98-100001  Single Mode Optical Splitter/Coupler  1 
 11.4.1.1.  Single Mode Optical Splitter/Coupler (98-100001) 
Single Mode Optical Splitter/Couplers are used whenever it is necessary to split or combine outputs 
from optical transmitters or inputs to receivers. Operators should be aware that a small insertion loss 
(typically 3-4dB) is common with these type of couplers.  
Single Mode Optical Splitter/Coupler (98-100001) It is an O.E.M unit featuring almost negligible 
insertion loss to the F/O signal. Extreme caution should be exercised when handling these devices. 
Special attention should be shown to the connectors; repair of a broken Splitter/Coupler is not 
possible; replacement is the only option. 
In the Fibre Optic Splitter (55-165507) in University Station Master Site 1 (80-330552-1), Single Mode 
Optical Splitter/Coupler (98-100001) is used to split the optical signal from the FO TX module in F/O 
Link Subsystem (98-700001) into two equal paths. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 180 of 500 
11.4.2.  800MHz FO Hub Amplifier + Filters (55-165601) 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
11.4.2.3.  02-007206  900MHZ 8POLE 25MHz+ B/W "SMA"  6 
11.4.2.4.  07-015105  ASYMMETRIC CPLR 30dB 800-2500MHz GA  3 
11.4.2.5.  10-000701  SW ATT 0-30dB 0.25W SMA F  2 
11.4.2.6.  11-005902K 900MHz LOW NOISE AMP WITH RELAY KIT  1 
11.4.2.7.  11-006702K 800-1000MHz LNA 29dB (cw RELAY) KIT  2 
11.4.2.8.  12-018002K PA 800-960MHz 20W CLASS A KIT  1 
11.4.2.9.  12-021901  Low Power Amplifier  2 
17-001109*  AGC Detector Assembly (Logarithmic)  1 
17-001117*  AGC Detector Assembly   1 
11.4.2.10. 
17-001201*  AGC Attenuator Assembly   2 
11.4.2.11.  20-001601  12V RELAY BOARD  1 
11.4.2.12.  80-008901  12V RELAY PCB ASSEMBLY  1 
11.4.2.13.  94-100004  STPS12045TV 60A DUAL DIODE  1 
11.4.2.14. 96-200047  DC/DC Converter   
11.4.2.15.  96-300052  JWS150-12/A PSU (COUTANT LAMBDA)  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz FO Hub Amplifier + Filters (55-165601); 17-001117 and 17-001201 
are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 181 of 500 
 11.4.2.1.  800MHz FO Hub Amplifier + Filters (55-165601) outline drawing 
drawing number 55-1656101 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 182 of 500 
 11.4.2.2.  800MHz FO Hub Amplifier + Filters (55-165601) system diagram  
drawing number 55-165681 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 183 of 500 
 11.4.2.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 11.4.2.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 184 of 500 
 11.4.2.5. Switched Attenuator 0.25Watt, 0 - 30dB (10-000701) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
Switched Attenuator 10-000701 provides attenuation from 0 to 30dB in 2 dB steps The attenuation is 
simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly 
marked with the attenuation it provides, and the total attenuation in line is the sum of the values 
switched in. They are designed to maintain an accurate 50Ω impedance over their operating 
frequency at both input and output. 
10-000701 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-30dB 
Attenuation Steps 2, 4, 8 and 16dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation  -20°C to +60°C Temperature 
range  storage  -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 185 of 500 
 11.4.2.6.  Low Noise Amplifier (11-005902) 
The Gallium-Arsenide low noise amplifier used in the unit is a double stage, solid-state low noise 
amplifier. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low 
noise over a very wide dynamic range. The active devices are very moderately rated to provide a long 
trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a 
failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm 
system which gives a volt-free relay contact type alarm that is easily integrated into any alarm system. 
There is a Current Fault Alarm Function, which indicates failure of each one or both RF transistors by 
a various alarm output options. The amplifier is housed in an aluminium case (Iridite NCP finish) with 
SMA connectors for the RF input/output and a 9way D-type for DC and alarm outputs.  
11-005902 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 960MHz * 
Bandwidth: <170MHz 
Gain: 19.5dB (typical) 
1dB compression point: 21dBm 
OIP3: 33dBm 
Input/output return loss: >20dB 
Noise figure: 1dB (typical) 
Power consumption: 190mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C Temperature 
range  storage: -40°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 0.28kg  *tuned to Customer's specification 
 LNA ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm relay O/P bad 
4  Alarm relay common 
5  Alarm relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 186 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
 11.4.2.7.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 187 of 500 
 11.4.2.8.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 188 of 500 
 11.4.2.9.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 189 of 500 
 11.4.2.10. Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz FO Hub Amplifier + Filters (55-165601); 17-001117 and 17-001201 
are paired for use in the uplink and 17-001109 and 17-001201 are paired for use in the down link 
800MHz FO Hub Amplifier + Filters (55-165601) is fitted with two differing types of Automatic Gain 
Control (AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-
001117) is fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the 
downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the down link 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 190 of 500 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 11.4.2.11. 12V (Dual) Relay Board (20-001601) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw 
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the 
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on 
neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay 
contact pair for the main alarm system. 
20-001601 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage: 8 to 30V (floating earth) 
Alarm threshold: Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current: 1.0Amp 
Max. switch volts: 120Vdc/60VA 
Max. switch power: 24W/60VA 
Min. switch load: 10.0µA/10.0mV 
Relay isolation: 1.5kV 
Mechanical life: >2x107 operations 
Relay approval: BT type 56 
Connector details: Screw terminals 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 191 of 500 
 11.4.2.12. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector.  
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
 11.4.2.13. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 192 of 500 
 11.4.2.14. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 11.4.2.15. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  (absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 193 of 500 
 11.4.3.  700MHz FO Hub Amplifier (55-165602) 
700MHz FO Hub Amplifier (55-165602) List of major components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
11.4.3.3.  02-007206  900MHZ 8POLE 25MHz+ B/W "SMA"  2 
11.4.3.4.  07-015105  ASYMMETRIC CPLR 30dB 800-2500MHz GA  2 
11.4.3.5.  10-000701  SW ATT 0-30dB 0.25W SMA F  2 
11.4.3.6.  11-005902  900MHz LOW NOISE AMP WITH RELAY KIT  1 
11.4.3.7.  11-006702  800-1000MHz LNA 29dB (cw RELAY) KIT  2 
11.4.3.8.  12-018002  PA 800-960MHz 20W CLASS A KIT  1 
11.4.3.9.  12-021901  Low Power Amplifier  2 
17-001109  AGC Detector Assembly (Logarithmic)  1 
17-001117  AGC Detector Assembly   1 
11.4.3.10. 
17-001201  AGC Attenuator Assembly   2 
11.4.3.11.  20-001601  12V RELAY BOARD  1 
11.4.3.12.  80-008901  12V RELAY PCB ASSEMBLY  1 
11.4.3.13.  94-100004  STPS12045TV 60A DUAL DIODE  1 
11.4.3.14. 96-200047  DC/DC Converter   
11.4.3.15.  96-300052  JWS150-12/A PSU (COUTANT LAMBDA)  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 700MHz FO Hub Amplifier (55-165602); 17-001117 and 17-001201 are paired 
for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 194 of 500 
 11.4.3.1.  700MHz FO Hub Amplifier (55-165602) outline drawing 
drawing number 55-1656102 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 195 of 500 
 11.4.3.2.  700MHz FO Hub Amplifier (55-165602) system diagram 
drawing number 55-165682 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 196 of 500 
 11.4.3.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 11.4.3.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling leve: -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 197 of 500 
 11.4.3.5. Switched Attenuator 0.25Watt, 0 - 30dB (10-000701) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
Switched Attenuator 10-000701 provides attenuation from 0 to 30dB in 2 dB steps The attenuation is 
simply set using the four miniature toggle switches on the top of each unit. Each switch is clearly 
marked with the attenuation it provides, and the total attenuation in line is the sum of the values 
switched in. They are designed to maintain an accurate 50Ω impedance over their operating 
frequency at both input and output. 
10-000701 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-30dB 
Attenuation Steps 2, 4, 8 and 16dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation  -20°C to +60°C Temperature 
range  storage  -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 198 of 500 
 11.4.3.6.  Low Noise Amplifier (11-005902) 
The Gallium-Arsenide low noise amplifier used in the unit is a double stage, solid-state low noise 
amplifier. Class A circuitry is used throughout the units to ensure excellent linearity and extremely low 
noise over a very wide dynamic range. The active devices are very moderately rated to provide a long 
trouble-free working life. There are no adjustments on these amplifiers, and in the unlikely event of a 
failure, then the complete amplifier should be replaced. This amplifier features its own in-built alarm 
system which gives a volt-free relay contact type alarm that is easily integrated into any alarm system. 
There is a Current Fault Alarm Function, which indicates failure of each one or both RF transistors by 
a various alarm output options. The amplifier is housed in an aluminium case (Iridite NCP finish) with 
SMA connectors for the RF input/output and a 9way D-type for DC and alarm outputs.  
11-005902 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 960MHz * 
Bandwidth: <170MHz 
Gain: 19.5dB (typical) 
1dB compression point: 21dBm 
OIP3: 33dBm 
Input/output return loss: >20dB 
Noise figure: 1dB (typical) 
Power consumption: 190mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C Temperature 
range  storage: -40°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 0.28kg  *tuned to Customer's specification 
 LNA ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm relay O/P bad 
4  Alarm relay common 
5  Alarm relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 199 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
 11.4.3.7.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 200 of 500 
 11.4.3.8.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 201 of 500 
 111.4.3.9. Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 202 of 500 
 11.4.3.10. Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 700MHz FO Hub Amplifier (55-165602); 17-001117 and 17-001201 are paired 
for use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 
700MHz FO Hub Amplifier (55-165602) is fitted with two differing types of Automatic Gain Control 
(AGC) system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is 
fitted in the uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the downlink 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 203 of 500 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 11.4.3.11. 12V (Dual) Relay Board (20-001601) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw 
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the 
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on 
neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay 
contact pair for the main alarm system. 
20-001601 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage: 8 to 30V (floating earth) 
Alarm threshold: Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current: 1.0Amp 
Max. switch volts: 120Vdc/60VA 
Max. switch power: 24W/60VA 
Min. switch load: 10.0µA/10.0mV 
Relay isolation: 1.5kV 
Mechanical life: >2x107 operations 
Relay approval: BT type 56 
Connector details: Screw terminals 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 204 of 500 
 11.4.3.12. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. 
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
 11.4.3.13. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs. They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 205 of 500 
 11.4.3.14. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 11.4.3.15. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  (absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 206 of 500 
 11.4.4.  700MHz FO HUB Splitter/Combiner (55-165603) 
700MHz FO HUB Splitter/Combiner (55-165603) list of major components 
 section Component 
Part  Component Part Description  Qty. Per 
Assembly 
11.4.4.2.  05-003302  4 WAY SPLITTER GSM 900MHz  2 
11.4.4.1.  700MHz FO HUB Splitter/Combiner (55-165603) system diagram 
drawing number 55-165683 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 207 of 500 
 11.4.4.2.  Four Way Splitter/Combiner (05-003302) 
The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an 
appropriate 50Ω load. 
Four Way Splitter (05-003302) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 700-980MHz 
Bandwidth 180MHz 
Rejection >14dB 
Insertion loss <7.0dB (in band) 
Connectors N type, female 
Weight <1.5kg 
operational -20%C to +60%C Temperature 
range  storage -40%C to +70%C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 208 of 500 
UNIVERSITY  STATION. SPLITTER 2
20/09/07
55-1657112
PB
18/10/2007
GD
18/10/2007
1:2
OUTLINE DRAWING
PL
100.00
150.00
420.00
483
463.0
65 5x FIXING HOLES SUITABLE
FOR M5 FIXINGS
180.0
PORT JA2
PORT JA1
PORT JB3
PORT JB2
PORT JB1
PORT I1 PORT I2
3.00
PRODUCT NUMBER : 55-165712
MATERIAL: CHASSIS - ALUMINIUM
FINISH : IRIDITE
CONNECTORS : 'N' TYPE SOCKETS
83.0
10.0
AA ORIGINAL ISSUE PL
 11.4.5. UNIVERSITY ST. SPLITTER 2 (55-165712) 
UNIVERSITY ST. SPLITTER 2 (55-165712) List of major Components 
 section  Component 
Parts  Component Part Description  Qty. Per 
Assembly
11.4.5.3.  07-015102  ASYMMETRIC CPLR 10dB 800-2500MHz GA  3 
 11.4.5.1.  University Station Splitter 2 (55-165712) outline drawing  
drawing number 55-1657112 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 209 of 500 
 11.4.5.2.  University Station Splitter 2 (55-165712) system diagram  
drawing number 55-165792 
 11.4.5.3. Wideband Asymmetric Coupler (07-015102) 
The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 
10dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015102 Specification 
 PARAMETER  SPECIFICATION 
Frequency Range 800 - 2500 MHz 
Coupling Value 10 dB ± 1.0 dB 
Main Line Insertion Loss <1.6 dB 
VSWR 1.4:1 
Directivity >18 dB 
Power Rating 200 Watts 
RF Connectors ‘N’ female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 210 of 500 
 11.4.6.  Optical AB Switch FC/APC (98-700002)  
Optical A/B Switch FC/APC (98-700002) an O.E.M. sourced Fibre Optic relay supplied as a 1U rack 
mount tray. 98-700002 allows for the automatic switching between two optical inputs to provide a 
common optical output. Manual selection of the input is also possible via toggle switches on the front 
panel. 
98-700002 Specification  
 PARAMETER  SPECIFICATION 
Electrical Characteristics 
Power Supply Voltage  100 - 240 VAC 
Power Supply Frequency 50 - 60 Hz 
Optical Characteristics 
Operating Wavelength  1200 – 1610nm 
Optical Input Range  +20 dBm 
Optical Insertion Loss  2.0 dB 
Optical Trip Threshold/Meter Range  -35 - +20 dBm 
Optical Switch Speed  15ms 
Backreflection Tolerance  -50dB 
Environmental and Physical Characteristics 
Optical Connectors  FC/APC 
Operating Temp. Range  +10 to +40°C 
Storage Temp. Range  -40 to +80 °C   
Humidity  5 to 90 % RHNC 
Weight  2.2 kg (6 lbs) 
Dimensions  483 x 361 x 44mm (19.0 x 14.2 x 1.72 in.) 
 11.4.7.  F/O Link Subsystem (98-800001) 
F/O Link Subsystem (98-800001) is an O.E.M. sourced Optical Tranceiver package containing 
discreet TX and RX modules and supplied as a 1U rack mount tray  
 Parameter  Specification 
Optical Output Power 4 mW 
Wavelength, peak 1310 1550 nm  
Frequency Response, 50 to 2.2 GHz ± 1.5 dB 
Input and Output VSWR 1.5:1  
Link Gain (2) 0 dB 
Output Noise Floor (1) -137 dBm/Hz 
Input 3rd Order Intercept (1) 30 dBm 
Operating Temperature  −30 to +75°C 
Storage Temperature −40 to +85°C 
Maximum RF Input to Transmitter +20 dBm 
Maximum Optical Input to Receiver 6 mW 
A.C. Supply Voltage 90 – 265 VAC 
Dimensions 483 x 457 x 44mm (19.0 x 18 x 1.72 in.) 
(1) SFDR, Noise and IP3 specified with 5 dB optical loss. 
(2) Link Gain specified with 1 meter fiber. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 211 of 500 
12. WESTLAKE STATION LINE AMPLIFIER (80-330553) 
rack number C03-CR-06 
Westlake Station Line Amplifier (80-330553) list of major components 
Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
12.4.1.  55-165703  800MHz LINE AMP + FILTERS (INT AMP)  2 
12.4.2.  55-165704  700MHz LINE AMP + FILTERS (INT AMP)  2 
12.4.3.  55-165707  WESTLAKE ST. SPLITTER  1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 212 of 500 
 12.1. Westlake Station Line Amplifier (80-330553) rack elevation  
drawing number 80-330553 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 213 of 500 
 12.2. Westlake Station Line Amplifier (80-330553) system diagram  
drawing number 80-330583 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 214 of 500 
 12.3. Westlake Station Line Amplifier (80-330553) alarm wiring diagram 
drawing number 80-330523 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 215 of 500 
 12.4. Westlake Station Line Amplifier (80-330553) Sub Components 
 12.4.1.  800MHz Line Amplifier (55-165703) 
800MHz Line Amplifier (55-165703) List of Major Components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
12.4.1.3. 02-007206 Bandpass Filter  4 
12.4.1.4.  07-015105  Wideband Asymmetric Coupler  1 
12.4.1.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 
12.4.1.6.  11-006702  Low Noise Amplifier  1 
12.4.1.7.  12-018002  Power Amplifier (20W 800MHz )  1 
12.4.1.8.  12-021901  Low Power Amplifier  2 
17-001109*  AGC Detector Assembly (Logarithmic)  1 
17-001117*  AGC Detector Assembly  1 
12.4.1.9. 
17-001201*  AGC Attenuator Assembly  2 
12.4.1.10.  20-001601  12V (Dual) Relay Board  1 
12.4.1.11.  80-008901  12V (Single) Relay Board  1 
12.4.1.12.  94-100004  Dual Diode Assembly  1 
12.4.1.13. 96-200047  DC/DC Converter  1 
12.4.1.14.  96-300052  12V Switch-Mode PSU  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for 
use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 216 of 500 
 12.4.1.1.  800MHz Line Amplifier (55-165703) Outline Drawing 
Drawing number 55-1657103 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 217 of 500 
 12.4.1.2.  800MHz Line Amplifier (55-165703) System Diagram  
Drawing number 55-165783 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 218 of 500 
 12.4.1.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 12.4.1.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 219 of 500 
 12.4.1.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the 
four miniature toggle switches on the top of each unit. Each switch is clearly marked with the 
attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are 
designed to maintain an accurate 50Ω impedance over their operating frequency at both input and 
output. 
10-000901 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-15dB 
Attenuation Steps 1, 2, 4 and 8dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weigh 0.2kg 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
 12.4.1.6.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 800MHz Line Amplifier (55-165703) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 220 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 
 12.4.1.7.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
12-018002 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 221 of 500 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 12.4.1.8.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 222 of 500 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 12.4.1.9.  Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for 
use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 
800MHz Line Amplifier (55-165703) is fitted with two differing types of Automatic Gain Control (AGC) 
system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the 
uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the downlink 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 223 of 500 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 
AGC Specification (both types) 
 PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 12.4.1.10. 12V (Dual) Relay Board (20-001601) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with two dual pole change-over relays with completely isolated wiring, accessed via screw 
terminals. Both relays are provided with polarity protection diodes and diodes for suppressing the 
transients caused by "flywheel effect" which can destroy switching transistors or induce spikes on 
neighbouring circuits. It’s common use is to amalgamate all the alarm signals into one, volts-free relay 
contact pair for the main alarm system. 
20-001601 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage: 8 to 30V (floating earth) 
Alarm threshold: Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current: 1.0Amp 
Max. switch volts: 120Vdc/60VA 
Max. switch power: 24W/60VA 
Min. switch load: 10.0µA/10.0mV 
Relay isolation: 1.5kV 
Mechanical life: >2x107 operations 
Relay approval: BT type 56 
Connector details: Screw terminals 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 224 of 500 
 12.4.1.11. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. 
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
 12.4.1.12. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 225 of 500 
 12.4.1.13. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 12.4.1.14. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  
(absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 226 of 500 
 12.4.2  700MHz Line Amplifier (55-165704) 
Description of 700MHz Line Amplifier (55-165704) 
700MHz Line Amplifier (55-165704) List of Major Components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
12.4.2.3. 02-007206 Bandpass Filter  4 
12.4.2.4.  07-015105  Wideband Asymmetric Coupler  1 
12.4.2.5.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  2 
12.4.2.6.  11-006702  Low Noise Amplifier  1 
12.4.2.7.  12-018002  Power Amplifier (20W 800MHz )  1 
12.4.2.8.  12-021901  Low Power Amplifier  2 
17-001109*  AGC Detector Assembly (Logarithmic)  1 
17-001117*  AGC Detector Assembly  1 
12.4.2.9. 
17-001201*  AGC Attenuator Assembly  2 
12.4.2.10.  80-008901  12V (Single) Relay Board  1 
12.4.2.11.  94-100004  Dual Diode Assembly  1 
12.4.2.12.  96-200047  DC/DC Converter   1 
12.4.2.13.  96-300052  12V Switch-Mode PSU  1 
*The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 800MHz Line Amplifier (55-165703); 17-001117 and 17-001201 are paired for 
use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 227 of 500 
 12.4.2.1.  700MHz Line Amplifier (55-165704) Outline Drawing  
Drawing number 55-1657104 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 228 of 500 
 12.4.2.2.  700MHz Line Amplifier (55-165704) System Diagram  
Drawing number 55-165784 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 229 of 500 
 12.4.2.3.  Bandpass Filter (02-007206) 
The bandpass filters are multi-section designs with a bandwidth dependent upon the passband 
frequencies, (both tuned to customer requirements). The response shape is basically Chebyshev with 
a passband design ripple of 0.1dB. The filters are of slot coupled, folded combline design, and are 
carefully aligned during manufacture in order to optimise the insertion loss, VSWR and 
intermodulation characteristics of the unit. The tuned elements are silver-plated to reduce surface 
ohmic losses and maintain a good VSWR figure and 50Ω load at the input and output ports. 
Being passive devices, the bandpass filters should have an extremely long operational life and require 
no maintenance. Should a filter be suspect, it is usually most time efficient to replace the module 
rather than attempt repair or re-tuning. 
No adjustments should be attempted without full network sweep analysis facilities to monitor both 
insertion loss and VSWR simultaneously. 
02-007206 Specification 
 PARAMETER  SPECIFICATION 
Response type Chebyshev 
Frequency range 800 - 950MHz * 
Bandwidth 25MHz * 
Number of sections 8 
Insertion loss 1.2 dB 
VSWR better than 1.2:1 
Connectors SMA female 
Power handling 100W max 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
Weight 3 kg (typical)  *tuned to Customer's specification 
 12.4.2.4. Wideband Asymmetric Coupler (07-015105) 
The purpose of Wideband Asymmetric Coupler (07-015105) is to tap off a known portion (in this case 
30dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015105 Specification 
 PARAMETER  SPECIFICATION 
Construction Inductive air gap 
Frequency 800-2500MHz 
Through loss 0.4dB (typical) 
Coupling level -30dB ±0.5dB 
Isolation N/A 
Weight <1.0kg 
Connectors SMA, female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 230 of 500 
 12.4.2.5. Switched Attenuator 0.25W, 0 - 15dB (10-000901) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the 
four miniature toggle switches on the top of each unit. Each switch is clearly marked with the 
attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are 
designed to maintain an accurate 50Ω impedance over their operating frequency at both input and 
output. 
10-000901 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-15dB 
Attenuation Steps 1, 2, 4 and 8dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weigh 0.2kg 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 
 12.4.2.6.  Low Noise Amplifier (11-006702) 
The Gallium-Arsenide low noise amplifiers used in 700MHz Line Amplifier (55-165704) are double 
stage, solid-state low noise amplifiers. Class A circuitry is used throughout the units to ensure 
excellent linearity and extremely low noise over a very wide dynamic range. The active devices are 
very moderately rated to provide a long trouble-free working life. There are no adjustments on these 
amplifiers, and in the unlikely event of a failure, then the complete amplifier should be replaced. This 
amplifier features its own in-built alarm system which gives a volt-free relay contact type alarm that is 
easily integrated into the main alarm system. 
11-006702 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800 – 1000MHz 
Bandwidth: <200MHz 
Gain: 29dB (typical) 
1dB Compression point: 20dBm 
OIP3: 33dBm 
Input/Output return loss: >18dB 
Noise figure: 1.3dB (typical) 
Power consumption: 180mA @ 24V DC 
Supply voltage: 10-24V DC 
Connectors: SMA female 
operational: -10°C to +60°C 
Temperature range:  storage: -20°C to +70°C 
Size: 90 x 55 x 30.2mm 
Weight: 290gms (approximately) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 231 of 500 
7 8 96
1 2 3 4 5
9-Way Pin-Out Graphical Representation
Low Noise Amplifier (11-006702) ‘D’ Connector Pin-out details 
 Connector pin  Signal 
1  +Ve input (10-24V) 
2 GND 
3  Alarm RelayO/P bad 
4  Alarm Relay common 
5  Alarm Relay good 
6 No connection 
7  TTL voltage set 
8  TTL alarm/0V (good) 
9  O/C good/0V bad 
 12.4.2.7.  Power Amplifier (12-018002) 
This amplifier is a Class A 20W power amplifier from 800-960MHz in a 1 stage balanced 
configuration. It demonstrates a very high linearity and a very good input/output return loss (RL). It 
has built in a Current Fault Alarm Function. 
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
Technical Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 800-960MHz 
Small signal gain: 30dB 
Gain flatness: ±1.2dB 
I/O Return loss: >18dB 
1dB compression point: 42.8dBm 
OIP3: 56dBm 
Supply voltage: 24V DC 
Supply current: 5.0Amps (Typical) 
operational: -10°C to +60°C Temperature 
range  storage: -20°C to +70°C 
Weight: <2kg (no heatsink) 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 232 of 500 
Power Amplifier (12-018002) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 12.4.2.8.  Low Power Amplifier (12-021901) 
The low power amplifier used is a triple stage solid-state low-noise amplifier. Class A circuitry is used 
in the unit to ensure excellent linearity over a very wide dynamic range. The three active devices are 
very moderately rated to provide a long trouble-free working life.  
Its housing is an aluminium case (Iridite NCP finish) with SMA connectors for the RF input/output and 
a D-Type connector for the power supply and the Current Fault Alarm Function. 
There are no adjustments on this amplifier, and in the unlikely event of failure then the entire amplifier 
should be replaced. 
Low Power Amplifier (12-021901) Specification 
 PARAMETER  SPECIFICATION 
Frequency range 800-960MHz* 
Bandwidth 20MHz * 
Maximum RF output >1.0 Watt 
Gain 15dB 
1dB compression point +30.5dBm 
3rd order intercept point +43dBm 
Noise Figure <6dB 
VSWR better than 1.5:1 
Connectors SMA female 
Supply 500mA @ 10-15V DC 
operational -10°C to +60°C 
Temperature 
range  storage -20°C to +70°C 
Weight 0.5 kg 
Size 167x52x25mm 
* Tuned to Customer’s specification 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 233 of 500 
Low Power Amplifier (12-021901) 7-Way Connector Pin-outs 
 Connector Pin  Signal 
A1 (large pin)  +24V DC 
A2 (large pin)  GND 
1  Alarm relay common 
2  TTL alarm/0V good 
3  Alarm relay contact (bad) 
4  Alarm relay contact (good) 
5  O/C good/0V bad (TTL) 
 12.4.2.9.  Automatic Gain Control 
17-001109  AGC Detector Assembly (Logarithmic) 
17-001117  AGC Detector Assembly  
17-001201  AGC Attenuator Assembly  
The sub components 17-001109, 17-001117 & 17-001201 are parts of the Automatic Gain Control 
(AGC) system used in 700MHz Line Amplifier (55-165704); 17-001117 and 17-001201 are paired for 
use in the uplink and 17-001109 and 17-001201 are paired for use in the downlink 
700MHz Line Amplifier (55-165704) is fitted with two differing types of Automatic Gain Control (AGC) 
system, one linear, and one logarithmic. The AGC with logarithmic detector (17-001117) is fitted in the 
uplink path and the AGC with linear detector (17-001109) is fitted in the downlink path  
The AFL Automatic Gain Control system consists of two units, a detector/amplifier and an attenuator. 
The detector/amplifier unit is inserted in the RF path on the output of the power amplifier, and the 
attenuator is situated in the RF path between the 1st and 2nd stages of amplification.  
17-001117 and 17-001201 are paired for use in the uplink and 17-001109 and 17-001201 are paired 
for use in the downlink 
The attenuator comprises a 50Ω P.I.N diode, voltage-variable attenuator with a range of 3 to 30dB. 
The attenuation is controlled by a DC voltage which is derived from the associated detector controller 
board. 
Normally the attenuator is at minimum attenuation. The detector/amplifier unit monitors the RF level 
being delivered by the power amplifier, and when a certain threshold is reached it begins to increase 
the value of the attenuator to limit the RF output to the (factory set) threshold. Therefore overloading 
of the power amplifier is avoided. 
The factory set threshold is 1dB below the Enhancer 1dB compression point. Some adjustment of this 
AGC threshold level is possible, a 10dB range is mostly achieved. It is not recommended under any 
circumstances to adjust the AGC threshold to a level greater than the 1dB compression point as 
system degradation will occur. 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 234 of 500 
The detector comprises of a 50Ω transmission line with a resistive tap which samples a small portion 
of the mainline power. The sampled signal is amplified and fed to a conventional half wave diode 
rectifier, the output of which is a DC voltage proportional to the RF input signal. 
This DC voltage is passed via an inverting DC amplifier with integrating characteristics, to the output, 
which drives the attenuation control line of the corresponding AGC attenuator. This unit is fitted at 
some earlier point in the RF circuit. 
For small signals, below AGC onset, the output control line will be close to 12V and the AGC 
attenuator will have minimum attenuation. As the signal level increases the control line voltage will 
fall, increasing the attenuator value and keeping the system output level at a constant value. 
AGC Specification (both types) 
PARAMETER  SPECIFICATION 
Frequency range up to 1000MHz 
Attenuation range 3 to 30dB  
Attenuation steps continuously variable 
VSWR better than 1.2:1 
RF Connectors SMA female 
attenuator 1W Power 
handling  detector/amp >30W (or as required) 
operation -10°C to +60°C Temperature 
range  storage -20°C to +70°C 
attenuator pcb 50 x 42 x 21mm 
Size  detector/amp pcb 54 x 42 x 21mm 
attenuator 90grams 
Weight  detector/amp 100grams 
 12.4.2.10. 12V (Single) Relay Board (80-008901) 
The General Purpose Relay Board allows the inversion of signals and the isolation of circuits. It is 
equipped with a single dual pole change-over relay RL1, with completely isolated wiring, accessed 
via a 15 way in-line connector. 
The relay is provided with polarity protection diodes and diodes for suppressing the transients caused 
by "flywheel effect" which can destroy switching transistors or induce spikes on neighbouring circuits. 
It’s common use is to amalgamate all the alarm signals into one, volts-free relay contact pair for the 
main alarm system. 
80-008901 Specification 
 PARAMETER  SPECIFICATION 
Operating voltage 8 to 30V (floating earth) 
Alarm threshold Vcc - 1.20 volt +15% 
Alarm output relay contacts: 
Max. switch current 1.0Amp 
Max. switch volts 120Vdc/60VA 
Max. switch power 24W/60VA 
Min. switch load 10.0µA/10.0mV 
Relay isolation 1.5kV 
Mechanical life >2x107 operations 
Relay approval BT type 56 
Connector details Screw terminals 
operational -10°C to +60°C Temperature 
range  storage -20°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 235 of 500 
 12.4.2.11. Dual Diode Assembly (94-100004) 
The purpose of these dual diode assemblies is to allow two DC voltage sources to be combined, so 
that the main DC rail within the equipment can be sourced from either a mains driven PSU, or 
externally through an XLR connector or from dual mains driven PSUs . They are very heavy-duty 
diodes and they prevent any reverse current from flowing back to their source or the alternative 
supply rail. Combining diodes such as these will also be used if the equipment is to be powered from 
external back-up batteries. 
 12.4.2.12. DC/DC Converter 96-200047 
96-200047 is an O.E.M. high power device with a wide input range and 12.5 amp @ 12V (150Watts) 
output capability used to derive a 12V fixed voltage power supply rail from a higher voltage supply, in 
this case 12V. In the event of failure this unit should not be repaired, only replaced. 
96-200047 Specification 
 PARAMETER  SPECIFICATION 
DC Input Voltage range 19 to 36V 
DC Output voltage 12V ± 1% 
Max. current load 12.5Amps 
Operation -10°C to +60°C Temperature 
range  Storage -20°C to +85°C 
Working Humidity 20 to 90% RHNC 
 12.4.2.13. 12V Switch-Mode PSU (96-300052) 
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from 
the power supply may be measured on its output terminals. This is typically set to 12.2V. The 
adjustment potentiometer will be found close to the DC output terminals. 
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal 
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by 
the operator. 
96-300052 Specification 
 AC Input Supply  110 or 220V nominal 
Voltage 85 - 265V AC  
(absolute limits) 
Frequency 47 to 63Hz 
DC Output Supply  12V DC (nominal) 
Voltage 10.5-13.8V (absolute limits) 
Current 12.5A 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 236 of 500 
 12.4.3. Westlake Station. Splitter (55-165707) 
2U rack mount chassis 
Westlake Station. Splitter (55-165707) list of major components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
12.4.3.3.  07-015102  Wideband Asymmetric Coupler  5 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 237 of 500 
 12.4.3.1. Westlake Station. Splitter (55-165707) outline drawing  
Drawing number 55-1657107 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 238 of 500 
 12.4.3.2. Westlake Station. Splitter (55-165707) system diagram 
Drawing number 55-165787 
 12.4.3.3. Wideband Asymmetric Coupler (07-015102) 
The purpose of Wideband Asymmetric Coupler (07-015102) is to tap off a known portion (in this case 
10dB) of RF signal from transmission lines and to combine them, for example through splitter units for 
different purposes (alarms/monitoring etc.), whilst maintaining an accurate 50Ω load to all 
ports/interfaces throughout the specified frequency range. They are known formally as directional 
couplers as they couple power from the RF mainline in one direction only.  
07-015102 Specification 
 PARAMETER  SPECIFICATION 
Frequency Range 800 - 2500 MHz 
Coupling Value 10 dB ± 1.0 dB 
Main Line Insertion Loss <1.6 dB 
VSWR 1.4:1 
Directivity >18 dB 
Power Rating 200 Watts 
RF Connectors ‘N’ female 
operation -20°C to +60°C 
Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 239 of 500 
13  ATTENUATOR SHELF (ITAC) 1 (55-165506) 
Attenuator Shelf (ITAC) 1 (55-165506) list of major components 
Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
13.3.1. 05-002602  900MHz Splitter/Combiner  1 
13.3.2.  05-003007  4 Port Hybrid Coupler  1 
13.3.3. 09-000902  Dummy load  1 
13.3.4.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  1 
13.3.5.  10-002960  25W 2.5GHz 60dB ATTENUATOR N M/F  1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 240 of 500 
 13.1. Attenuator Shelf (ITAC) 1 (55-165506) outline drawing  
Drawing number 55-1655106 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 241 of 500 
 13.2  Attenuator Shelf (ITAC) 1 (55-165506) system diagram  
Drawing number 55-165586  

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 242 of 500 
 13.3. Attenuator Shelf (ITAC) 1 (55-165506) major components 
 13.3.1.  900MHz Splitter/Combiner (05-002602) 
The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an 
appropriate 50Ω load. 
Being passive devices, the splitters should have an extremely long operational life and require no 
maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module 
rather than attempt repair or re-tuning. 
05-002602 Specification 
 PARAMETER  SPECIFICATION 
Narrowband 815 – 960MHz Frequency 
range  Broadband 800 – 1200MHz 
Narrowband 145MHz 
Bandwidth  Broadband 400MHz 
Input ports 1 
Output ports 2 
Narrowband 3.3dB 
Insertion loss  Broadband 3.5dB 
Return loss input & output 1.3:1 
Impedance 50Ω 
Narrowband >20dB 
Isolation  Broadband >18dB 
MTFB >180,000 hours 
Splitting 20Watts 
Power rating  Combining 0.5Watt 
Connectors SMA female 
Weight 200g (approximately) 
Size 54 x 44 x 21mm  
 13.3.2.  4 Port Hybrid Coupler (05-003007) 
This transmitter hybrid coupler is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 
50Ω load. In this specific instance one port of 4 Port Hybrid Coupler (05-003007) is terminated with 
Dummy load 09-000902 (see below). 
05-003007 Specification 
 PARAMETER  SPECIFICATION 
Frequency range 700-900MHz 
Bandwidth 200MHz 
Rejection >14dB 
Insertion loss 6.5dB (in band, typical) 
Connectors SMA 
Weight <1.0kg 
operational -10%C to +60%C Temperature 
range  storage -20%C to +70%C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 243 of 500 
 13.3.3.  Dummy load (09-000902) 
When a combiner system is used to split or combine RF signals, in many cases it is most cost 
effective to use a standard stock item 4, 6 or 8 port device where, in fact, only a 3 or 6 port device is 
needed. In this case 4 Port Hybrid Coupler (05-003007) has one of its ports terminated with Dummy 
load (09-000902) in order to preserve the correct impedance of the device over the specified 
frequency range. 
09-000902 specification 
 PARAMETER  SPECIFICATION 
Frequency Range 0 - 2500 MHz 
Power Rating 25 Watts continuous 
VSWR Better than 1.1:1 
Impedance 50 Ohms 
Temperature Range -20 to +60°C 
RF Connectors N Type female 
Dimension 110.3mm x 38.1mm x 
Weight 485 grams 
Finish Black Anodised 
RF Connector N Type male 
Environmental IP66 
MTBF >180,000 hours 
 13.3.4.  Switched Attenuator 0.25W, 0 - 15dB (10-000901) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the 
four miniature toggle switches on the top of each unit. Each switch is clearly marked with the 
attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are 
designed to maintain an accurate 50Ω impedance over their operating frequency at both input and 
output. 
10-000901 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-15dB 
Attenuation Steps 1, 2, 4 and 8dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 244 of 500 
 13.3.5.  Attenuator 25W, 60dB (10-002960) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. Attenuator 25W, 60dB (10-002960) is a fixed attenuator providing 60dB of signal attenuation. 
10-002960 Specification 
 PARAMETER  SPECIFICATION 
Frequency Range DC to 2.5GHz 
Power Handling 25 W 
Attenuation 60 dB 
Attenuation Accuracy ± 0.5dB 
Return Loss to 2.2GHz 18dB 
Nominal Impedance 50 Ω 
RF Conectors N male to N female 
Finish  Matt Black Anodise 
operational -20%C to +55%C 
Temperature 
range  storage -20%C to +70%C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 245 of 500 
14  ATTENUATOR SHELF (ITAC) 2 (55-165506) 
Attenuator Shelf (ITAC) 2 (55-165506) list of major components 
 Section  Component 
Part  Component Part Description  Qty. Per 
Assembly 
13.3.1. 05-002602  900MHz Splitter/Combiner  1 
13.3.2.  05-003007  4 Port Hybrid Coupler  1 
13.3.3. 09-000902  Dummy load  1 
13.3.4.  10-000901  Switched Attenuator 0.25W, 0 - 15dB  1 
13.3.5.  10-002960  Attenuator 25W, 60dB  1 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 246 of 500 
 14.1. Attenuator Shelf (ITAC) 2 (55-165506) outline drawing  
Drawing number 55-1655106 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 247 of 500 
 14.2  Attenuator Shelf (ITAC) 2 (55-165506) system diagram  
Drawing number 55-165586  

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 248 of 500 
 14.3. Attenuator Shelf (ITAC) 2 (55-165506) major components 
 14.3.1.  900MHz Splitter/Combiner (05-002602) 
The Splitter/Combiner used is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
VSWR and insertion losses are kept to a minimum. Any unused ports should be terminated with an 
appropriate 50Ω load. 
Being passive devices, the splitters should have an extremely long operational life and require no 
maintenance. Should a unit be suspect, it is usually most time efficient to replace the whole module 
rather than attempt repair or re-tuning. 
05-002602 Specification 
 PARAMETER  SPECIFICATION 
Narrowband 815 – 960MHz Frequency 
range  Broadband 800 – 1200MHz 
Narrowband 145MHz 
Bandwidth  Broadband 400MHz 
Input ports 1 
Output ports 2 
Narrowband 3.3dB 
Insertion loss  Broadband 3.5dB 
Return loss input & output 1.3:1 
Impedance 50Ω 
Narrowband >20dB 
Isolation  Broadband >18dB 
MTFB >180,000 hours 
Splitting 20Watts 
Power rating  Combining 0.5Watt 
Connectors SMA female 
Weight 200g (approximately) 
Size 54 x 44 x 21mm  
 14.3.2.  4 Port Hybrid Coupler (05-003007) 
This transmitter hybrid coupler is a device for accurately matching two or more RF signals to single or 
multiple ports, whilst maintaining an accurate 50Ω load to all inputs/outputs and ensuring that the 
insertion losses are kept to a minimum. Any unused ports should be terminated with an appropriate 
50Ω load. In this specific instance one port of 4 Port Hybrid Coupler (05-003007) is terminated with 
Dummy load 09-000902 (see below). 
05-003007 Specification 
 PARAMETER  SPECIFICATION 
Frequency range: 700-900MHz 
Bandwidth: 200MHz 
Rejection: >14dB 
Insertion loss: 6.5dB (in band, typical) 
Connectors: SMA 
Weight: <1.0kg 
operational
:-10%C to +60%C 
Temperature 
range:  storage -20%C to +70%C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 249 of 500 
 14.3.3.  Dummy load 09-000902 
When a combiner system is used to split or combine RF signals, in many cases it is most cost 
effective to use a standard stock item 4, 6 or 8 port device where, in fact, only a 3 or 6 port device is 
needed. In this case 4 Port Hybrid Coupler (05-003007) has one of its ports terminated with Dummy 
load (09-000902) in order to preserve the correct impedance of the device over the specified 
frequency range. 
09-000902 specification 
 PARAMETER  SPECIFICATION 
Frequency Range 0 - 2500 MHz 
Power Rating 25 Watts continuous 
VSWR Better than 1.1:1 
Impedance 50 Ohms 
Temperature Range -20 to +60°C 
RF Connectors N Type female 
Dimension 110.3mm x 38.1mm x 
Weight 485 grams 
Finish Black Anodised 
RF Connector N Type male 
Environmental IP66 
MTBF >180,000 hours 
 14.3.4.  Switched Attenuator 0.25W, 0 - 15dB (10-000901) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. 
10-000901 provides attenuation from 0 - 15dB in 2 dB steps The attenuation is simply set using the 
four miniature toggle switches on the top of each unit. Each switch is clearly marked with the 
attenuation it provides, and the total attenuation in line is the sum of the values switched in. They are 
designed to maintain an accurate 50Ω impedance over their operating frequency at both input and 
output. 
10-000901 Specification 
 PARAMETER  SPECIFICATION 
Attenuation Values 0-15dB 
Attenuation Steps 1, 2, 4 and 8dB 
Power Handling 0.25 Watt 
Attenuation Accuracy ± 1.0 dB 
Frequency Range DC to 1GHz 
Impedance 50Ω 
Connectors SMA 
VSWR 1.3:1 
Weight 0.2kg 
operation -20°C to +60°C Temperature 
range  storage -40°C to +70°C 

STTRS DOCUMENTATION 
Document Number 80-330501HBKM – Issue A - Draft  Page 250 of 500 
 14.3.5.  Attenuator 25W, 60dB (10-002960) 
In many practical applications for Cell Enhancers etc., the gain in each path is found to be excessive. 
Therefore, provision is made within the unit for the setting of attenuation in each path, to reduce the 
gain. Attenuator 25W, 60dB (10-002960) is a fixed attenuator providing 60dB of signal attenuation. 
10-002960 Specification 
 PARAMETER  SPECIFICATION 
Frequency Range DC to 2.5GHz 
Power Handling 25 W 
Attenuation 60 dB 
Attenuation Accuracy ± 0.5dB 
Return Loss to 2.2GHz 18dB 
Nominal Impedance 50 Ω 
RF Conectors N male to N female 
Finish  Matt Black Anodise 
operational -20%C to +55%C 
Temperature 