Axon Enterprise S00146 Body Worn POV Camera System User Manual
TASER International Body Worn POV Camera System Users Manual
Users Manual
Axon Flex 2 User Manual Models AX1005, AX1006 IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions. Save these Instructions. The most up-to-date warnings and instructions are available at www.taser.com. MMU#### Rev: X Contents Chapter 1: Introduction ...................................................................................................................... 1 What Is the Axon Flex 2 Camera System...................................................................................... 1 Important Safety and Health Information ................................................................................... 1 Additional Reading .......................................................................................................................... 1 Chapter 2: Getting to Know Your Axon Flex 2 Camera .................................................................. 3 Axon Flex 2 Features ....................................................................................................................... 3 Axon Flex 2 Camera ..................................................................................................................... 3 Axon Flex 2 Controller ................................................................................................................. 4 Axon Flex 2 Cables and Connectors ............................................................................................. 7 Straight-to-Right-Angle Connector ............................................................................................ 7 USB Cable...................................................................................................................................... 7 Axon RapidLock Mount................................................................................................................... 7 Parts ............................................................................................................................................... 8 Assembly and Use ....................................................................................................................... 8 Other Equipment Mounting Options ........................................................................................ 9 Chapter 3: Hardware Details .......................................................................................................... 10 Preparing the Axon Flex 2 Camera ............................................................................................ 10 Using the Camera Clip ................................................................................................................. 12 Attaching the Camera to the Clip ........................................................................................... 12 Removing the Camera from the Clip ..................................................................................... 13 Attaching the Clip to a Mount ................................................................................................. 14 Chapter 4: Recording with the Axon Flex 2 Camera ................................................................... 15 BUFFERING Mode (Turning on the Camera) ......................................................................... 15 EVENT Mode (Starting Recording) .......................................................................................... 16 Muting Audio Recording .............................................................................................................. 17 Adding Markers to Recorded Video ........................................................................................... 17 Battery Status ................................................................................................................................ 17 Configuring Your Axon Camera.................................................................................................. 17 Adjusting the Audio Prompt Volume ..................................................................................... 17 Turning off the Camera LEDs (Stealth Mode) ....................................................................... 18 Using Axon View ....................................................................................................................... 18 Pairing Your Axon Flex 2 Camera with a Smart Device ....................................................... 18 Other Settings ........................................................................................................................... 19 Chapter 5: Notification Reference Tables ..................................................................................... 20 Audio Prompts .............................................................................................................................. 20 LED Status ...................................................................................................................................... 20 Controller Operation LED ........................................................................................................ 20 Controller Function LED........................................................................................................... 21 Controller Battery LED ............................................................................................................. 21 Camera Upload Status LED ..................................................................................................... 21 Chapter 6: Axon Signal Operations................................................................................................ 23 Chapter 7: Care and Maintenance ................................................................................................. 24 Cleaning the Axon Flex 2 Camera .............................................................................................. 24 Charging the Battery .................................................................................................................... 24 Replacing the Battery ................................................................................................................... 25 Chapter 8: Troubleshooting ............................................................................................................ 26 Customer Service.......................................................................................................................... 26 Warranty Policy ............................................................................................................................. 26 Declaration of Conformity ........................................................................................................... 26 Radio Waves .................................................................................................................................. 26 ii Chapter 1: Introduction What Is the Axon Flex 2 Camera System The Axon Flex 2 is a camera system incorporating an audio and video recording device. This camera is designed for use in tough environmental conditions encountered in law enforcement, corrections, military, and security activities. The Axon Flex 2 camera is designed to record events for secure storage, retrieval, and analysis via Evidence.com services. The recorded events are transferred to your storage solution via the Axon Dock, or by using Evidence Sync software installed on a Windows computer. The Axon Flex 2 camera has 2 operating modes designed to accommodate the needs of law enforcement, corrections, security, and the military. The default mode, or BUFFERING mode, provides pre-event buffering to capture activities that occur prior to the user activating the EVENT mode. In addition, the Axon View application enables playback of footage on a smart device for review prior to storing the data. Important Safety and Health Information WARNING! Read, understand, and follow all warnings and instructions before using this product. The most up-to-date warnings and instructions are available at www.taser.com. Additional Reading This manual explains how to operate the Axon Flex 2 camera hardware. Other manuals cover additional aspects of the Axon Flex 2 system. These documents are available at www.taser.com. The Axon Academy website explains how to register for the Evidence.com website, configure settings, install Evidence Sync software, assign personnel to cameras, recharge your camera, and transfer video from an Axon device to a computer. Visit academy.axon.io/. Detailed instructions for using Axon cameras and other TASER products with Evidence Sync are available in the Evidence Sync User Manual. For instructions on using Axon cameras with a smart device, see the Axon View for Android Devices User Manual or the Axon View for iOS Devices User Manual. If you have an Axon Dock, see the Axon Dock Quick Start Guide for how to transfer information and recharge your camera. Chapter 2: Getting to Know Your Axon Flex 2 Camera Axon Flex 2 Features The primary Axon Flex 2 components are the camera and controller. Axon Flex 2 Camera The camera offers high quality video and low-light gathering capabilities. The camera is designed to store at least 12 hours of video (and up to 70 hours based on the video setting). If the camera is full (has reached its storage limit), the camera will not record over previous video but instead stops recording. If notifications are turned on, the sytem will alert with 3 beeps and 3 vibrations and the camera will not start recording when the memory is full. USB connector LED Speaker Imager (lens) Microphone Imager – This is the camera lens. Avoid touching the lens. For cleaning information, see Chapter 5 Care and Maintenance in this manual. LEDs – the LEDs will illuminate when in the dock to signify status of uploads or firmware updates. USB Connector – This feature on the back of the camera connects to a cable leading to the Axon Flex 2 controller. Microphone – Records ambient sound. Speaker – Issues alerts in the form of beeps. Axon Flex 2 Controller The Axon Flex 2 camera includes physical controls to enable video and audio capture while providing visual, audible, and vibration notifications of the Axon Flex 2 camera’s state of operation. Note: You can turn off the controller LEDs, if necessary. See Turning off the Controller LEDs (Chapter 4) for instructions. top view Function LED Operation LED Connection Socket front view On/Off Switch On/Off Indicator Speaker Slide Lock Function Button EVENT button Battery LED Battery Status Button Operation LED Shows the camera’s current operating mode ”for battery status, see the Battery LED, described below). Operating Mode Operation LED EVENT Blinking red BUFFERING Blinking green Operating Mode Operation LED Recovering interrupted video* Booting up/powering down Solid red Error state** * When the Function LED also is blinking red. Interrupted video is video that was stopped incorrectly (for example a sudden power loss). ** When the Function LED also is solid red. Controller Function LED Shows when certain functions are enabled. Function Enabled Function LED Mute Blinking blue Camera error* Solid red Bluetooth feature is booting up Solid blue * Use the power switch to turn the camera off and on. Connection Socket – Enables data transfer and recharging. Slide Lock – Holds the cable to the controller. On/Off Switch – Turns the camera’s power on or off. On/Off Indicator – When the camera’s power is turned on, the red portion is exposed. When the camera power is turned off, the red portion is covered from view. Speaker – Provides audio notifications. Function Button – Used in device pairing, to mute the device, and to add markers to the video as it is recorded. EVENT Button – Used to start and stop recording. (Double-press to start; hold for 4 seconds to stop recording.) The camera might take several additional seconds to close out of the video when it is powered off before stopping an event. Battery Status Button – When pressed, the Battery button lights up the Battery LED, which momentarily indicates the remaining battery capacity only (with default settings, the Battery LED does not indicate the operating mode). Battery LED When lit, momentarily indicates the remaining battery capacity (with default settings, it does not indicate the operating mode). When you turn the camera on, the Operation LED turns solid red until the system is ready to use. Then the Operation LED blinks green (BUFFERING mode). The camera can be configured so the Battery LED operates in sync with the Operation LED. In BUFFERING mode both the Operation and Battery LEDs will blink green, and in EVENT mode both will blink red. If the battery status button is pressed, the battery LED displays the battery status for approximately 10 seconds and then resumes displaying the EVENT mode. Battery Status Battery LED Battery capacity is 41–100 percent Green Battery capacity is 20–40 percent Yellow Battery capacity is less than 20 percent Red during operation; flashing red and yellow during charging Battery is critically low Blinking red and yellow BUFFERING mode (if configured) Blinking green EVENT mode (if configured) Blinking red Dual-Channel Microphone – For audio recording. Upload Status LED Indicates status when the camera is uploading data to the Evidence.com website via the Axon Dock. System Status Upload Status LED Initial connection (momentary) Solid red (for 20 seconds or fewer) In queue awaiting upload Solid yellow Device ready (all videos uploaded successfully) and fully charged Solid green Device not assigned, agency mismatch, camera set in the offline mode, or device error Blinking red Uploading data Blinking yellow – DO NOT remove the camera from the Axon Dock Firmware update, internal battery charging, extremely low battery, or memory full Blinking red and yellow – DO NOT remove the camera from the Axon Dock Transfer error, device re-trying to transfer Blinking green and yellow Network error (no connection) Blinking red, yellow, and then green (cycling all colors) Axon Dock has no communication with the camera. Contact TASER customer service. LED off Lens – The camera lens. Pressing buttons causes the Axon Flex 2 camera to emit audio alerts (beeps) to indicate system actions. See Chapter 4: Notification Reference Tables for more information. Axon Flex 2 Cables and Connectors Straight-to-Right-Angle Connector The Axon Flex 2 camera and controller are designed to work with a purpose-built cable, with a straight connector at one end and a right-angle connector at the other. Insert the straight connector into the camera and the right-angle connector into the controller. CAUTION! POTENTIAL DATA LOSS These cables are specifically calibrated to work with the Axon Flex 2 system. Use of unapproved cables will degrade system performance and may cause the system to not function properly or at all. Ensure that your cables are inserted properly into the camera and controller. If the camera’s battery is low, or the cable is disconnected, your recorded video will be lost. USB Cable A USB cable is available to connect the Axon Flex 2 camera directly to your computer. The cable used with the Axon Flex 2 system is not the same as the cable used with the Axon Flex system. The cables are not interchangeable. CAUTION! ENSURE SOFTWARE IS INSTALLED Do NOT connect your Axon Flex 2 camera to your computer before you have installed the Evidence Sync software. Axon RapidLock Mount The Axon Flex 2 controller is designed to work with the Axon RapidLock mounting system. The Axon RapidLock mounting system consists of the attachment piece (called the key) on the camera and the various mounting options including the attachment receiver (called the lock). To engage the Axon RapidLock, insert the key of the camera into the lock of the mount and turn it 90 degrees counterclockwise (when you are looking straight at the mount). To release the camera from the mount, turn the camera 90 degrees clockwise. The various mounts that use this system can be used with a wide variety uniforms, and holds the camera to your shirt, patrol vest, jacket, or belt. Parts back lock controller Assembly and Use WARNING! IMPORTANT SAFETY AND HEALTH INFORMATION Read Important Safety and Health Information (Chapter 1) and Chapter 9: Error! Reference source not found. before performing these steps. Insert the key on the back of the Axon Flex 2 controller into the lock. Twist the RapidLock mount counterclockwise, 90 degrees. Place the magnetic back underneath the shirt, patrol vest, or whatever you are using. Hold the back in place, and place the RapidLock mount over the back. Magnetic attraction will hold the controller in place. Other Equipment Mounting Options The Axon Flex 2 system provides you with a variety of ways to wear your camera. A variety of mounts enable the camera to be attached to your Oakley Flak Jacket eyewear, shirt collar or epaulette, load bearing equipment, helmet, or cap. Additional information on Axon Flex 2 mounting options is available at www.axon.io. Chapter 3: Hardware Details This chapter describes preparing and wearing the Flex 2 camera system. For additional information on using the universal mount and other mounts, see the instructional videos for assembling Axon Flex 2 hardware at www.axon.io. WARNING! AXON SYSTEM USE If the camera system causes discomfort or headaches, adjust the system for comfort. NEVER wrap cables around the neck. The Axon Flex 2 system uses magnets in many of its mounting systems. The Axon Flex 2 camera and Axon Flex 2 controller both contain batteries. Preparing the Axon Flex 2 Camera All Axon Flex 2 cameras shipped from the factory are configured to be installed on the right side of the body. If you wish to wear a camera on the left side, you will have to adjust your settings through the Evidence Sync software or on the Evidence.com website to re-orient the camera. The side on which you wear the camera is configured through the Evidence Sync software. Try wearing your camera on your dominant side and your non-dominant side to find what works best for you. If you have the Axon View application, you can view live video and determine if the camera is pointed where you want it. See the Axon View for Android Devices or Axon View for iOS Devices manuals for more information on how to do this. Cable connectors are inserted into the rear of the Axon Flex 2 camera. If you do not connect the cable to the camera properly, the connection may not be secure. 10 The controller has a Slide Lock that is retracted before inserting the cable into the port. After putting the cable in the port, release the slide. Ensure that it closes properly. 11 Using the Camera Clip Several mounting systems are available for the Axon Flex 2 camera, enabling you to wear the camera in different ways. The camera does not attach directly to a mount. Instead, the camera is attached to a camera clip, and the clip is then fitted to the mount. Axon Flex 2 camera attached to the clip Attaching the Camera to the Clip To attach the camera to the clip, push the camera straight into the clip as shown. 12 Removing the Camera from the Clip To remove the camera from the clip, roll the camera out. front view 13 Attaching the Clip to a Mount With the camera attached to the clip, press the clip onto the mounting system you are using. 14 Chapter 4: Recording with the Axon Flex 2 Camera The Axon Flex 2 camera has 2 operating modes: BUFFERING (turning on the camera and starting pre-event buffering) EVENT (event recording) BUFFERING Mode (Turning on the Camera) Move the On/Off switch on the controller to the On position. With the camera turned on, the Axon system is in the BUFFERING mode. When BUFFERING begins: • The Operation LED on the camera will blink green. • The camera will be capturing video but no audio, and will not record to permanent memory while in BUFFERING mode. • Buffered video duration is 30 seconds by default (00:00:30). When you activate the EVENT mode, the buffered video (not audio) captured directly before the event, up to 30 seconds, will be saved and attached to the event in permanent 15 memory. This feature is intended to capture the video of an incident just before your activation of EVENT mode. CAUTION! OPERATING MODES With default settings, the system does not capture audio in BUFFERING mode, so anything recorded in that mode will be video-only. Buffering mode starts only after the Axon Flex 2 camera is turned on. The system does not record when the camera is turned off. Notes: • An agency can turn off the BUFFERING mode. If your agency has deactivated the BUFFERING mode, your Axon system will operate the same way as described in this manual, but the camera will not record anything until you double-press the EVENT button. • An agency can extend the BUFFERING mode’s duration to 2 minutes total ”00:02:00). • An agency can configure the BUFFERING mode so it records sound as well as video. EVENT Mode (Starting Recording) When you need to record, quickly double-press the EVENT button on the camera. The system now records audio as well as video. The buffered video directly preceding the event will be saved and attached to the event recording. (Remember, with default settings, the buffered video will not contain audio.) The moment you double-press the EVENT button, both video and audio will be recorded from the camera and GPS coordinates (if the system is paired to a GPS-capable smart phone) will be recorded. This will continue throughout the duration of the recording until you terminate the recording. The camera provides you with indications that it is recording in EVENT mode: • At the start of an event and every 2 minutes during an event, the system will beep twice. • The Operation LED on top of the camera will blink red. To stop recording and return to BUFFERING mode, press and hold the EVENT button for approximately 4 seconds. The system will beep once (with a long tone). To end a recording and turn off the system, move the On/Off switch to the off position. When you end a recording with the on/off switch you will not go into BUFFERING mode; instead the system will turn off completely. Note: An event not recorded by the camera cannot be played back or downloaded to your computer. 16 Muting Audio Recording If your system administrator has configured your Axon system to do so, you can use the function button to disable audio recording during an event. This feature may be useful in sensitive situations. Press and hold the Function button for 3 seconds to mute the audio capture. The Function LED will flash blue while the camera is muted. Press and hold the Function button another 3 seconds to re-enable the audio recording. Adding Markers to Recorded Video The Function button also can be used to add a marker to recorded video that will show when the video is replayed on Evidence.com and documented in the audit trail for the device. Markers are most useful for documenting a moment that you will want to jump to quickly at a later time when re playing the video. If you want to add a marker to a video while you are recording: • Press and release the Function button within 1 second. Battery Status Press the Battery Status button to determine the percentage remaining in the battery. See Chapter 2: Getting to Know Your Axon Flex 2 Camera for details on the Battery LED functions. Configuring Your Axon Camera Adjusting the Audio Prompt Volume Connect the Axon Flex 2 camera to the Evidence Sync application. Select the device settings. Select the desired volume settings for the audio beeps recorded by the device. The volume has 4 settings. At each level, the camera beeps, providing you with a sample of the volume: • Low • Medium • High 17 • Off Turning off the Camera LEDs (Stealth Mode) For some situations, you may wish to turn off the LED lights on your camera. You can turn off the lights through the Axon View application, Evidence Sync software or by using the Battery button. To turn the lights off using the Battery Status button: • Press and hold the Battery button for 10 seconds. To turn the lights back on: • Press and hold the Battery Status button for 10 seconds. To use Evidence Sync: Connect the Axon Flex 2 camera to the Evidence Sync application. Select the device settings. Select the option to turn off the device LEDs. • The Operation LED flashes red, yellow, and then green before shutting down the lights. • Pressing the Battery button will momentarily light both the Operation LED and the Battery LED, displaying the current operating mode and battery level. For interpreting the LED colors, see Chapter 2: Getting to Know Your Axon Flex 2 Camera. To turn the lights back on: • Connect the Axon Flex 2 camera to the Evidence Sync application. • Select the device settings. • Select the option to turn on the device LEDs. Using Axon View See the Axon View for Android Devices User Manual or the Axon View for iOS Devices User Manual. Pairing Your Axon Flex 2 Camera with a Smart Device For instructions on using Axon cameras with a smart device, see the Axon View for Android Devices User Manual or the Axon View for iOS Devices User Manual. 18 Other Settings Your organization’s administrator can further configure your Axon Flex 2 system with these features: • Pre-event buffer of up to 2 minutes • Axon Signal-enabled Bluetooth wireless technology • Wi-Fi to pair your Axon Flex 2 camera to the Axon View application • Haptic (status notification via device vibration) • Video quality 19 Chapter 5: Notification Reference Tables Audio Prompts The Axon Flex 2 camera emits beeping sounds called audio prompts to notify you of the system status. These audio prompts usually occur after you perform an action with the body camera. These audio prompts are accompanied by a vibration that matches the beeps. Operating Mode Audio Notification Haptic Notification (Vibration) Powering on or off One beep Once Recording an event Two beeps (every 2 minutes) Twice (every 2 minutes) Press the Battery button while the camera is recording Two beeps None The device is ending an event and returning to BUFFERING mode One long beep Once, long-duration The battery is at 20 percent capacity or lower Four quick beeps (every 5 minutes) Four times, quickly, every 5 minutes The camera memory is full Three beeps. The camera will not start recording. Three times LED Status Controller Operation LED Shows the camera’s current operating mode ”for battery status, see the Battery LED, described below). Operating Mode Operation LED EVENT Blinking red BUFFERING Blinking green Recovering interrupted video* 20 Operating Mode Booting up/powering down Operation LED Solid red Error state** * When the Function LED also is blinking red. ** When the Function LED also is solid red. Controller Function LED Shows when certain functions are enabled. Function Enabled Function LED Mute Blinking blue Camera error* Solid red Bluetooth feature is booting up Solid blue * Use the power switch to turn the camera off and on. Controller Battery LED Battery Status Battery LED Battery capacity is 41–100 percent Green Battery capacity is 20–40 percent Yellow Battery capacity is less than 20 percent Red during operation; flashing red and yellow during charging Battery is critically low Blinking red and yellow BUFFERING mode (if configured) Blinking green EVENT mode (if configured) Blinking red Camera Upload Status LED System Status Upload Status LED Initial connection (momentary) Solid red (for 20 seconds or fewer) In queue awaiting upload Solid yellow Device ready (all videos uploaded successfully) and fully charged Solid green Device not assigned, agency mismatch, camera set in the offline mode, or device error Blinking red Uploading data Blinking yellow – DO NOT remove the camera from the Axon Dock Firmware update, internal battery charging, extremely low battery, or memory full Blinking red and yellow – DO NOT remove the camera from the Axon Dock Transfer error, device re-trying to transfer Blinking green and yellow 21 System Status Upload Status LED Network error (no connection) Blinking red, yellow, and then green (cycling all colors) Axon Dock has no communication with the camera. Contact TASER customer service. LED off 22 Chapter 6: Axon Signal Operations Axon Signal technology is included with the Axon Flex 2 camera. However, your agency’s administrator must have activated the Axon Signal capability for it to work. When it is active, Axon Signal technology takes your Axon Flex 2 camera from BUFFERING to EVENT mode automatically. Emergency vehicles can be equipped with an Axon Signal Unit (ASU). With light bar activation, or other activation triggers, the ASU sends a signal to your Axon Flex 2 camera. Upon processing this signal, your Axon camera transitions from BUFFERING to EVENT mode. When your camera starts recording, you will hear 2 beeps. The ASU has a range of approximately 30 feet ”9.1 meters). Another vehicle’s light bar activation may cause your Axon camera to start recording if the light bar is equipped to do so. The ASU can only send a signal to tell the camera to start recording. Axon Signal technology does not end recording. If a light bar is turned off, the camera will continue to record. The ASU cannot turn an Axon system on. If the Axon Flex 2 camera is turned off, the camera will not record even if an ASU sends an activation signal. The ASU is purchased separately from the Axon Flex 2 camera. 23 Chapter 7: Care and Maintenance Cleaning the Axon Flex 2 Camera Use a soft, damp cloth to clean the surface of the Axon Flex 2 camera. Do not use harsh cleaners or solvents. Do not immerse the Axon Flex 2 camera in water or cleaning solutions. If the Axon Flex 2 camera lens becomes dirty, use a lens blower brush to clean it and then wipe it with a soft cloth if necessary. CAUTION! POSSIBLE EQUIPMENT DAMAGE • Do not use alcohol or alcohol-based liquids with the Axon Flex 2 system. • Do not use ammonia-based or similar type window cleaners on the camera lens. • Do not place the lens under running water or apply jets of water to the camera lens. Charging the Battery A fully charged controller battery should provide enough power for approximately 12 hours of normal operation. Recharging a battery after a 12-hour use can take up to 6 hours if you are recharging your Axon Flex 2 controller from a wall outlet or Axon Dock. Recharging could take considerably longer if you are recharging from a computer. If the battery depletes significantly during use, you will hear 4 quick tones repeating every 5 minutes. This message indicates that less than approximately 20 percent of the battery capacity remains. Always recharge a depleted battery as soon as reasonably possible. You can use an Axon Dock, wall charger, or computer to charge the battery. Using a non-TASER approved wall charger may degrade device performance and will void the warranty. If the Axon Flex 2 controller is to be stored for a long time, the Battery LED should be yellow when you put the controller in storage. After an Axon Flex 2 controller has been stored 6 months, the controller should be run until the battery is depleted and then the battery should be recharged. After an Axon Flex 2 controller has been stored more than 1 year, recharge the controller before using it. 24 Replacing the Battery Replacement batteries are not available with the Axon Flex 2 system. However, new controllers are sold separately. 25 Chapter 8: Troubleshooting If you experience difficulty with your Axon Flex 2 camera, first power the device down, and start it again. If experiencing difficulty with the Axon View application, power down the mobile device, turn the device back on, and re-pair your smart device with the Axon Flex 2 camera. Customer Service Visit www.axon.io and view the Support options, or call 1-800-978-2737. Warranty Policy TASER International warranty provisions are applicable on all Axon Flex 2 system products. See TASER International’s website, www.taser.com, for detailed warranty information. Declaration of Conformity TASER International declares that this Axon system is in compliance with the requirements and other relevant provisions of the RTT&E Directive 1999/5/EC regarding radio and telecommunications equipment and the Directive 2014/30/EU regarding electromagnetic compatibility. A copy of the original Declaration of Conformity can be found at www.taser.com. Radio Waves Changes or modifications to the equipment not expressly approved by the manufacturer could void the product warranty and the user’s authority to operate the equipment. Your wireless device is a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, 26 regardless of age and health. Before a device model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult TASER International Customer Service for help. FCC/IC NOTICE: This device meets the body worn human exposure limits found in OET Bulletin 65, 2001, and ANSI/IEEE C95.1, 1992. Proper operation of this equipment according to the instructions found in this guide will result in exposure substantially below the FCC’s recommended limits. To comply with the FCC and ANSI C95.1 RF exposure limits, this device has been tested for compliance with FCC RF Exposure limits in the typical configuration. The radiated output power of this wireless device is far below the FCC radio frequency exposure limits. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RSS 210 Warning Statement: The installer of this equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 6, obtainable from Heath Canada’s Web site www.hc‐sc.gc.ca/rpb. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : ”1) l’appareil ne doit pas produire de brouillage, et ”2) l’utilisateur de l’appareil doit accepter 27 tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. THIS MODEL DEVICE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Section 8.4 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux normes d’exemption de licence RSS d’Industrie Canada. Son utilisation est soumise aux conditions suivantes : 1) cet appareil ne doit pas causer de brouillage, et 2) doit accepter tout brouillage, y compris le brouillage pouvant entraîner un fonctionnement indésirable. Section 8.3 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of atype and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio ne peut fonctionner qu’au moyen d’une antenne d’un seul type et d’un gain maximal ”ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique pour les autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas celle requise pour établir une communication satisfaisante. THIS MODEL DEVICE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. 28 Product functions and specifications may change without notice and the actual product may vary from the illustrations in this manual. Android is a trademark of Google, Inc.; Bluetooth is a trademark of Bluetooth SIG; iPad, iPhone, iPod, and iTunes are trademarks of Apple, Inc.; IOS is a trademark of Cisco Technology, Inc.; Wi-Fi is a trademark of the Wi-Fi Alliance; and Windows is a trademark of Microsoft Corporation. AXON, Axon, Axon Flex 2, Axon Dock, Axon RapidLock, Axon Signal, Axon View, Evidence.com, Evidence Sync, TASER, and © are trademarks of TASER International, Inc., some of which are registered in the US and other countries. For more information, visit www.taser.com/legal. All rights reserved. © 2016 TASER International, Inc. 29 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information This document presents important safety warnings, instructions, and information intended to minimize hazards associated with the use of TASER International, Inc.’s (TASER) Axon camera systems. These instructions and warnings are for your protection as well as the safety of others. Read the entire document before using any Axon system. These warnings and instructions are effective December 12, 2016, and supersede all prior revisions. The most current warnings are also available online at www.taser.com. 1. Read and obey. Read, understand, and follow all current Axon system instructions, manuals, warnings, and relevant TASER training materials before using any Axon system. Failure to do so could increase the risk of serious injury, system malfunctions, or loss of data. 2. Obey applicable laws, regulations, and agency guidance. Use the Axon systems only in accordance with applicable federal, state, and local laws and other regulations or legal requirements. This document uses a signal word panel to mark specific warnings: WARNING This signal word panel indicates a potentially hazardous situation which if not avoided could result in fire, electric shock, damage, system malfunctions, death, or personal injury. CAUTION This signal word panel indicates a potentially hazardous situation which if not avoided or heeded could result in minor or moderate injury. Warnings may be followed by instructions and information to help avoid the hazard and improve safety. WARNING! POTENTIALLY EXPLOSIVE ENVIRONMENTS Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. Potentially explosive environments. Electric sparks in a potentially explosive area could cause an explosion or fire, resulting in serious injury or even death. Areas with a potentially explosive atmosphere are often, but not always, marked clearly. Potential areas may include: fueling areas (such as gas stations); below deck on boats; fuel or chemical transfer or storage facilities; vehicles using liquefied petroleum gas (such as propane or butane); areas where the air contains chemicals or particles (such as grain, dust, or metal powders); and any other area where you would normally be advised to turn off your vehicle engine. Axon Flex, Axon Flex 2, Axon Body, Axon Body 2, and Axon Fleet cameras contain wireless transmission technology that transfers radio frequencies over the air as a form of energy transfer. Wireless transmission has been deemed a risk factor in igniting an explosive environment. In situations where the Axon camera operator needs to enter a potentially explosive environment, TASER recommends that the user err on the side of caution and power off the camera before entering the explosive environment. An Axon camera should be treated the same as a cellular telephone would be treated in this situation. December 12, 2016 Page 1 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information WARNING! NEODYMIUM RARE EARTH MAGNETS Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. Neodymium Magnets. The Axon magnet mount contains a neodymium magnet which emits strong magnetic fields that can affect a pacemaker, ICD (implantable defibrillator), VNS (vagal nerve stimulator), and other implanted electrical medical devices. Many of these devices are made with a feature that deactivates it when in contact with a strong magnetic field. Therefore, care must be taken to avoid inadvertently deactivating such devices when in close proximity to the Axon magnet mount. Persons with a pacemaker, ICD, VNS, or other implanted electrical medical device should not wear the Axon magnet mount. WARNING! AXON DOCK USE Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. Electrical Warnings. To reduce the risk of fire, electric shock, or injury to persons when using any Dock, follow basic precautions, including the following: • Plug into a grounded 3-prong outlet and do not remove the ground prong. • Verify the outlet is installed according to applicable local electrical codes. • Do not use an adapter or an extension cord. • Disconnect power and verify power disconnect before servicing. • Keep away water, other liquids, corrosive substances, and flammable materials and vapors, such as gasoline. Keep away from sources of static electricity. Static electricity can cause damage to the Dock or cause it to malfunction. • In the event of electrostatic discharge or intermittent power fluctuation, power will need to be cycled to the unit to regain full functionality. CAUTION! AXON DOCK USE Maintenance. Failure to properly maintain the Dock may cause the system to malfunction or not operate optimally. To reduce the risk of malfunction, including failure or loss of data: 1. Anchoring and Installation. Docks should be securely placed on a flat surface; when anchoring (for example, to the wall or other hard and stable surface) be sure to use appropriate hardware. The following are guidelines for installation: • • • • Comply with your local and other applicable building and electricity regulations and codes; Install in an area with redundant power and redundant HVAC; Install in an area with an ambient temperature between 41 °F to 95 °F (5 °C to 35 °C); Leave adequate space around all sides of the Dock for proper ventilation and maneuvering around it without people or items bumping it; • Do not expose cords or wires which can be a tripping hazard; and • If mounted to a wall, secure to wall studs or with drywall or concrete anchors, as applicable. December 12, 2016 Page 2 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information 2. Indoor use only. The Dock is manufactured for indoor use only. Install the Dock indoors, away from excessive moisture, liquids, corrosive substances, or heat, dust, direct sunlight, water, or other negative environmental factors. In-car installations may expose the Dock to excessive heat. 3. Avoid water, other liquids, and wet locations. Do not install the Dock near or around liquids, water, or water pipes. Do not get the Dock wet. WARNING! AXON SYSTEM USE Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. To prevent potential injuries or system malfunctions or compromise, take the following precautions: 1. Handling the components. Ensure proper connections between the Axon components (e.g., the Axon Body camera is correctly inserted into the Dock). Do not drop, crush, disassemble, deform, open, incinerate, or insert foreign objects into the Axon system components. 2. Operate safely. Be careful and attentive while using an Axon system, including while operating a vehicle, riding a bicycle, operating other conveyance, when dealing with potentially violent individuals, or handling a hazardous or potentially hazardous situation. If you use an Axon system while operating a conveyance, keep in mind the following guidelines: • Do not take notes, look up information, adjust the camera, or perform any other activities that require or distract your attention. Give full attention to driving or riding and to the road. Using a mobile device or mobile data terminal (MDT) while driving or riding may be distracting. • Get to know the Axon system and its features. • Position the Axon system’s camera and activation buttons within easy reach. 3. Navigate safely. If your Axon system is paired or combined with a mobile phone or device or MDT and has applications that provide maps, digital compass headings, directions or location-based tracking or navigation assistance, these applications should only be used for basic navigation assistance and should not be relied on to determine precise locations, proximity, distance, or direction. Maps, digital compass, directions, and location-based applications provided by TASER depend on data collected and services provided by third parties. These data services are subject to change, may not be available in all geographic areas, or may not be accurate, resulting in maps, digital compass headings, directions, or location-based information that may be unavailable, inaccurate, or incomplete. Compare the information provided on the Axon system to your surroundings and defer to posted signs to resolve any discrepancies. 4. Wire and mount safety. If the system causes bodily discomfort discontinue use or find an alternative way to wear the equipment. Never wrap wires around your neck. 5. Avoiding hearing damage. Hearing damage, impairment, or loss may occur and may be permanent if an Axon Flex or Axon Flex 2 camera is mounted near your head and used at high volume. Set the volume to a safe and comfortable level. Be advised that you can adapt over time to a higher volume of sound that may sound normal but can be damaging to your hearing. 6. Choking hazards. The Axon systems contain small parts, which may present a choking hazard. Keep the Axon systems and their accessories away from small children. 7. Repetitive motion. When you perform repetitive activities such as typing on a mobile phone or device, you may experience occasional discomfort, which may create injury, including permanent injury, in your hand, wrist, arm, shoulder, neck, or other part of your body. Take frequent breaks and if you have discomfort during or after use, stop use and see a physician. 8. Use only TASER-approved components, batteries, and accessories. Only TASER-approved components, batteries, and accessories are to be used with the systems. Use of anything other than December 12, 2016 Page 3 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information TASER-approved components, batteries, or accessories will void the warranty, may cause malfunction, and may put the user or other person at risk of injury. WARNING! BATTERIES Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. Damage to or improper handling of batteries could result in fire, electric shock, damage, system malfunctions, loss of data, or personal injury. To prevent potential injuries, leaking, overheating or explosion of batteries, take the following precautions: 1. Do not replace the batteries in the Axon Flex system, Axon Flex 2 system, Axon Body camera, or Axon Fleet power unit. The batteries in the Axon Flex system, Axon Flex 2 system, Axon Body camera, and Axon Fleet power unit are not designed to be replaced. DO NOT attempt to replace these batteries. The Axon Body 2 camera battery is replaceable only with a TASERmanufactured battery. 2. Avoid extreme temperatures. Do not expose the battery to excessive heat, cold, water, other liquids, or corrosive substances. Do not use or leave the batteries for on-officer cameras near a heat source or at a very high temperature (for example, fire, heater, in strong direct sunlight, or in a vehicle in extremely hot weather). Otherwise, the battery may overheat, cause a fire, or its performance will be degenerated and its service life will be shortened. The battery in the Axon Fleet power unit is designed to be installed in the passenger compartment of a vehicle. Do not install the Axon Fleet power unit in the engine compartment, on the exterior of a vehicle, or in any location that will continually expose it to direct sunlight, water, other liquids, or corrosive substances. 3. Avoid static electricity. Keep the battery away from sources of static electricity. Static electricity can cause damage to the battery, which could result in serious injury. 4. Recharging. When recharging Axon equipment, use the Dock or TASER-approved power source specifically for that purpose. Do not reverse the positive (+) and negative (−) terminals. Do not connect the battery to an electrical outlet without using a TASER-approved adapter. The Axon Fleet power unit is designed to be recharged when the vehicle’s engine is running. Do not attempt to recharge the Axon Fleet power unit by other means. 5. Handling. Ensure proper connections between the Axon equipment when charging or docking an Axon component. To avoid risk of fire, burns, or damage to your battery pack, do not: allow a metal object to touch the battery contacts; strike or throw the battery; directly solder the battery or pierce the battery with a nail or other sharp object; disassemble, short circuit, or heat batteries; or put batteries in a fire. Doing so may cause battery explosion, battery leakage, system damage, injury, or fire. 6. Abnormal appearance. If the battery gives off an odor, generates heat, becomes discolored or deformed, or in any way appears abnormal during use, recharging or storage, immediately place the Axon component with the battery in a contained vessel such as a metal box. 7. Avoid battery acid contact with skin or eyes. In case the battery acid gets into the eyes due to the leakage of battery, do not rub the eyes. Rinse the eyes with clean running water, and immediately seek medical attention. Battery acid’s contact with the eyes or skin could cause serious injury, including a loss of eyesight. 8. Disposal. Dispose of any battery properly; contact your local waste disposal provider regarding local restrictions on the disposal or recycling of batteries. Do not dispose of the battery in fire or heat; the battery may explode if placed in the fire. Do not dispose of the battery in water. December 12, 2016 Page 4 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information WARNING! VEHICLE INSTALLATIONS Failure to follow these safety instructions could result in damage, system malfunctions, death, or personal injury. To prevent potential injuries or system malfunctions, take the following precautions: 1. Anchoring and Installation. If the Axon system is installed in the cab of the vehicle (in a location other than under the center console), it should be permanently mounted to avoid injury. Do not install an Axon system anywhere that will interfere with airbag deployment. 2. Avoid extreme temperatures. Do not expose the Axon system to excessive heat, cold, water, other liquids, or corrosive substances. Do not install the Axon system in the engine compartment, on the exterior of a vehicle, or in any location that will continually expose it to direct sunlight, water, other liquids, or corrosive substances. 3. Axon Dock in-Vehicle Caution. Installing an Axon Dock in a vehicle may expose the Dock to excessive temperatures. In-vehicle temperatures may exceed the threshold for recharging an Axon device in the Dock. WARNING! HAZARDOUS SUBSTANCES Failure to follow these safety instructions could result in fire, electric shock, damage, system malfunctions, death, or personal injury. Hazardous Substances. The Axon system has components that contain chemicals known to the State of California, U.S.A. and others to cause cancer and birth defects or other reproductive harm. Do not disassemble. Refer to your agency’s guidance for proper handling and disposal. CAUTION! LOSS OF DATA Read and obey. Always follow all current instructions, warnings, and TASER training materials to minimize risks and the loss of data. Properly Maintain the System. Failure to maintain or use the Axon system or Axon Dock (“Dock”) as instructed may cause the system to malfunction or fail to function properly or optimally. Recorded content in memory may be compromised, destroyed, or erased by operating mistakes, system or unit malfunction, or during repair work. Back up and save important content as necessary, after each shift, and before returning the unit for repair work. Installation and Update of Software. Install the Evidence Sync software on the appropriate computer before attempting to transfer files from an Axon camera to a computer or the Evidence.com services. Ensure the most recent software and firmware are installed on the system components. CAUTION! MAINTENANCE Failure to properly maintain or use the Axon system may cause the system to malfunction or fail to function properly or optimally, including failure to capture data and corruption of loss of data. To reduce the risk of malfunction, including failure, corruption or loss of data: December 12, 2016 Page 5 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information 1. Charging the battery. The Axon system batteries must be charged prior to use. Only use the approved TASER chargers, charging cables, or Dock units. Be aware that a battery can fail to function, fail to charge, fail to maintain a charge, or deteriorate over time. 2. Regularly update firmware and software. The Axon systems have the capability for firmware and software updating through the Evidence.com services or Evidence Sync software. It is important to acquire, update, and maintain the latest software update. Current software may be obtained from www.evidence.com. 3. Storage. Do not store the Axon system or its accessories in the following locations or under the following conditions: • Anywhere extremely hot, cold, or humid: o Axon on-officer cameras are not intended to be operated in temperatures above 122 °F (50 °C). o Axon on-officer cameras should not stored in environments where the temperature is likely to exceed 95 °F (35 °C) (such as under direct sunlight, near heaters, or in a vehicle in extremely hot weather) or exposed to temperatures below −4 °F (−20 °C). o Axon systems for automotive applications are rated for different temperatures. See the appropriate specification sheet. • With the battery completely drained. • Near strong magnetic fields or mechanical vibrations. 4. Exposure to Magnets or Magnetic Fields. Do not use the Axon system in close proximity to unauthorized magnets or magnetic fields, which may cause the Axon system to unintentionally turn the camera on or off. 5. Avoid Exposure to Wet Conditions. If a system component (including a camera or controller) is drenched or immersed in water, seawater, or other liquid, DO NOT use the component. Do not attempt to dry the Axon component with an external heat source, such as a microwave oven or hair dryer. An Axon component that has been damaged as a result of exposure to liquids is not serviceable. 6. Repairing or Modifying. Never attempt to repair or modify the Axon system yourself except as specifically outlined in the model specific operating instructions. Service should only be provided by TASER or an authorized service provider. Disassembling the Axon system may cause damage that is not covered under the product warranty. For service information, go to: www.taser.com. CAUTION! RADIO WAVES Radio Waves. Changes or modifications not expressly approved in writing by the manufacturer could void the user’s authority to operate the equipment. The Axon system contains a radio transmitter and receiver. It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government, Industry Canada (IC), and the recommendations of the Council of the European Union (EU). The FCC limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population. The FCC guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. Before a device model is available for sale to the public, it must be tested and December 12, 2016 Page 6 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information certified to the FCC that it does not exceed the limit established by the government‐adopted requirement for safe exposure. The Axon systems have been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Contact TASER’s Customer Service Department for help. FCC/IC NOTICE: The Axon systems meet the body worn human exposure limits found in OET Bulletin 65, 2001, and ANSI/IEEE C95.1, 1992. Proper operation of this radio according to the product instructions will result in exposure substantially below the FCC’s recommended limits. To comply with the FCC and ANSI C95.1 RF exposure limits, these devices have been tested for compliance with FCC RF Exposure limits in the typical configuration. The radiated output power of these wireless devices are far below the FCC radio frequency exposure limits. Axon systems comply with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) the device may not cause harmful interference, and (2) the device must accept any interference received, including interference that may cause undesired operation. NOTE: Unauthorized modifications could void the warranty and the user’s authority to operate the equipment. Axon systems comply with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) the device may not cause interference, and (2) the device must accept any interference, including interference that may cause undesired operation of the device. Axon systémes est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Section 8.4 of RSS-GEN Axon systems comply with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) the device may not cause interference, and 2) the device must accept any interference, including interference that may cause undesired operation of the device. Axon systems est conforme aux normes d’exemption de licence RSS d’Industrie Canada. Son utilisation est soumise aux conditions suivantes : 1) cet appareil ne doit pas causer de brouillage, et 2) doit accepter tout brouillage, y compris le brouillage pouvant entraîner un fonctionnement indésirable. Section 8.3 of RSS-GEN Under Industry Canada regulations, radio transmitters may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio December 12, 2016 Page 7 of 8 TASER Axon Flex, Axon Flex 2, Axon Fleet, Axon Body, Axon Body 2, Axon Dock, and Axon Signal Unit Warnings, Instructions & Information interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, émetteur radio ne peut fonctionner qu’au moyen d’une antenne d’un seul type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique pour les autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas celle requise pour établir une communication satisfaisante. AXON SYSTEMS MEET THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. AXON, Axon, Axon Body, Axon Body 2, Axon Dock, Axon Fleet, Axon Flex, Axon Flex 2, Evidence.com, Evidence Sync, TASER, and © are trademarks of TASER International, Inc., some of which are registered in the US and other countries. For more information, visit www.taser.com/legal. All rights reserved. © 2016 TASER International, Inc. December 12, 2016 Page 8 of 8
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 1 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:89f36feb-a29a-11f2-0000-02c7314339d4 Producer : GPL Ghostscript 9.18 Modify Date : 2017:07:16 23:25:01Z Create Date : 2017:07:16 23:25:01Z Creator Tool : UnknownApplication Document ID : uuid:89f36feb-a29a-11f2-0000-02c7314339d4 Format : application/pdf Title : UntitledEXIF Metadata provided by EXIF.tools