Axon Enterprise S00947 Body Worn Video Camera User Manual Manual
TASER International Body Worn Video Camera Manual
Contents
Manual

Contents 
i 
1  Chapter 1: Introduction 
1  What Is the Axon Body 2 Camera System? 
1  Important Safety and Health Information 
1 Additional Reading 
2 Chapter 2: Getting to Know Your Axon Body 2 Camera 
4  Accessories 
4 Parts 
5 Assembly and Use 
6 Chapter 3: Recording with the Axon Body 2 Camera 
6  Operating Modes 
6 BUFFERING Mode (Turning on the Camera) 
7 EVENT Mode (Starting Recording) 
7  Muting Audio Recording 
7 Adding Markers to Recorded Video 
8 Battery Status 
8  Configuring Your Axon Camera 
8  Adjusting the Audio Prompt Volume 
8
Turning off the Camera LEDs (Stealth Mode) 
9
Using Axon View 
9 Pairing Your Axon Body 2 Camera with a Smart Device 
10 Other Settings 
11 Chapter 4: Notification Reference Tables 
11 Audio Prompts 
11 LED Status 
11 Operation LED 
11 Function LED 
12 Battery LED 
12 Upload Status LED 

ii 
TASER Axon Body 2 Camera User Manual 
13 Chapter 5: Axon Signal Operations 
14 Chapter 6: Care and Maintenance 
14 Cleaning the Axon Body 2 Camera 
14 Charging the Battery 
15 Replacing the Battery 
16 Chapter 7: Troubleshooting 
16 Customer Service 
16 Warranty Policy 
16 Warnings 
16 Radio Waves 
18 Product Model Description 
18   Declaration of Conformity  

Chapter 1: Introduction 
1 
What Is the Axon Body 2 Camera System? 
The Axon Body 2 is a camera system incorporating an audio and video recording device. This camera is designed 
for  use  in  tough  environmental  conditions  encountered  in  law  enforcement,  corrections,  military,  and  security 
activities. The Axon Body 2 camera is designed to record events for secure storage, retrieval, and analysis via Evi- 
dence.com services. The recorded events are transferred to your storage solution via the Axon Dock 2, or by using 
Evidence Sync software installed on a Windows computer. 
The Axon  Body  2  camera  has  two  operating  modes  designed to  accommodate  the  needs  of  law  enforcement, 
corrections, security, and the military. The default mode, or BUFFERING mode, provides pre-event buffering to 
capture activities that occur prior to the user activating the EVENT mode. In addition, the Axon View application 
enables playback of footage on a smart device for review prior to storing the data. 
Important Safety and Health Information 
 WARNING 
Rare Earth Neodymium Magnets 
The Axon magnet mount contains a neodymium magnet which emits strong magnetic fields that can affect a 
pacemaker, ICD (implantable defibrillator), VNS (vagal nerve stimulator), and other implanted electrical medical 
devices. Many of these devices are made with a feature that deactivates it when in contact with a strong mag- 
netic field. Therefore, care must be taken to avoid inadvertently deactivating such devices when in close prox- 
imity to the Axon magnet mount. Persons with a pacemaker, ICD, VNS or other implanted electrical medical 
device should not wear the Axon magnet mount. 
Additional Reading 
This manual explains how to operate the Axon Body 2 camera hardware. Other manuals cover additional aspects 
of the Axon Body 2 system. These documents are available at www.taser.com. 
The Axon Academy website explains how to register for the Evidence.com website, configure settings, install Evi- 
dence Sync software, assign personnel to cameras, recharge your camera, and transfer video from an Axon device 
to a computer. Visit academy.axon.io/. 
Detailed instructions for using Axon cameras and other TASER products with Evidence Sync are available in the 
Evidence Sync User Manual. 
If you have an Axon Dock 2, see the Axon Dock 2 Quick Start Guide for how to transfer information and recharge 
your camera. 

2 
Chapter 2: Getting to Know Your Axon Body 2 
Camera 
The Axon Body 2 camera includes physical controls to enable video and audio capture while providing visual, au- 
dible, and vibration notifications of the Axon Body 2 camera’s state of operation. 
top view 
Function LED  Operation LED 
bottom view 
connection socket      
lens       
front view 
on/off switch 
upload status LED 
on/off indicator 
     Function button 
speaker       
EVENT button 
Battery LED 
dual-channel microphone        Battery status button 
Operation LED 
Shows the camera’s current operating mode (for Battery status, see the battery LED, described below). 
Operating Mode 
Operation LED 
Recording 
Blinking Red 
Buffering 
Blinking Green 
Booting up/powering down 
Error state 
Solid Red 

TASER Axon Body 2 Camera User 
Manual 
Chapter 2: Getting to Know Your Axon Body 2 Camera    3 
Function LED 
Shows when certain functions are enabled. 
Function Enabled 
Function LED 
Mute 
Blinking blue 
Camera error 
Solid red 
Bluetooth feature is booting up 
Solid blue 
Connection Socket – Enables data transfer and recharging. 
On/Off Switch – Turns the camera’s power on or off. 
On/Off Indicator – When the camera’s power is turned on, the red portion is exposed. When the camera power is 
turned off, the red portion is covered from view. 
Speaker – Provides audio notifications. 
Function Button – Used in device pairing, to mute the device, and to add markers to the video as it is recorded. 
EVENT Button – Used to start and stop recording. (Double-press to start; hold for four seconds to stop recording.) 
The camera might take several additional seconds to close out of the video when it is powered off before stopping 
an event. 
Battery Status Button – When pressed, the Battery button lights up the Battery LED, which momentarily indicates 
the remaining battery capacity only (it does not indicate the operating mode). 
Battery LED 
When lit, momentarily indicates the remaining battery capacity (it does not indicate the operating mode). 
Battery Status 
Battery LED 
Battery capacity is 41–100 percent 
Green 
Battery capacity is 20–40 percent 
Yellow 
Battery capacity is less than 20 percent 
Red during operation; flashing red and yellow during 
charging 
Battery is critically low 
Blinking red and yellow 
When you turn the camera on, the Operation LED turns solid red until the system is ready to use. Then the Opera- 
tion LED blinks green (BUFFERING mode) and the Battery LED goes out. 
Dual-Channel Microphone – For audio recording. 
Upload Status LED 
Indicates status when the camera is uploading data to the Evidence.com website via the Axon Dock 2. 
System Status 
Upload Status LED 
Initial connection (momentary) 
Solid red (for 20 seconds or fewer) 
In queue awaiting upload 
Solid yellow 
Device ready (all videos uploaded successfully) and ful- 
ly charged 
Solid green 

TASER Axon Body 2 Camera User 
Manual 
Chapter 2: Getting to Know Your Axon Body 2 Camera    4 
System Status 
Upload Status LED 
Device not assigned, agency mismatch, camera set in 
the offline mode, or device error 
Blinking red 
Uploading data 
Blinking yellow – DO NOT remove the camera from 
the Axon Dock 2 
Firmware update, internal battery charging, extremely 
low battery, or memory full 
Blinking red and yellow – DO NOT remove the camera 
from the Axon Dock 2 
Transfer error, device re-trying to transfer 
Blinking green and yellow 
Network error (no connection) 
Blinking red, yellow, and then green (cycling all colors) 
Axon Dock 2 has no communication with the camera. 
Contact TASER customer service. 
LED off 
Lens – The camera lens. 
Pressing buttons causes the Axon Body 2 camera to emit audio alerts (beeps) to indicate system actions. See Chap- 
ter 4: Notification Reference Tables or more information. 
Accessories 
The Axon  Body  2  camera  is  designed  to  work  with  the  new  Axon  RapidLock mounting  system.  The  RapidLock 
mounting system consists of the attachment piece (called the key) on the camera and the various mounting op- 
tions  including  the  attachment  receiver  (called  the  lock).  To engage  the  Axon  RapidLock,  insert  the  key  of  the 
camera into the lock of the mount and turn it 90 degrees counterclockwise (when you are looking straight at the 
mount). To release the camera from the mount, turn the camera 90 degrees clockwise. 
The various mounts that use this system can be used with a wide variety uniforms, and holds the camera to your 
shirt, patrol vest, jacket, or belt. 
Parts 
back  lock  camera 

TASER Axon Body 2 Camera User 
Manual 
Chapter 2: Getting to Know Your Axon Body 2 Camera    5 
Assembly and Use 
Read Important Safety and Health Information (Chapter 1) before performing these steps. 
1 Insert the key on the back of the Axon Body 2 camera into the lock. 
2 Twist the RapidLock mount counterclockwise, 90 degrees. 
3 Place the magnetic back underneath the shirt, patrol vest, or whatever you are using. 
4 Hold the back in place, and place the RapidLock mount over the back. Magnetic attraction will hold the 
camera in place. 
1  2 
4 
When you are wearing the camera, you can use the Axon View application’s live streaming feature to determine 
whether your camera is capturing the view you intended. 

6 
Chapter 3: Recording with the Axon Body 2 Camera 
Operating Modes 
The Axon Body 2 camera has two operating modes: 
1
BUFFERING (turning on the camera and starting pre-event buffering) 
2
EVENT (event recording) 
BUFFERING Mode (Turning on the Camera) 
1  Move the ON/OFF switch on the camera to the ON position. 
With the camera turned on, the Axon system is in the BUFFERING mode. When BUFFERING begins: 
• The Operation LED on the camera will blink green. 
• The camera will be capturing video but no audio, and will not record to permanent memory while in BUFFER- 
ING mode. 
• Buffered video duration is 30 seconds by default (00:00:30). 
When you activate the EVENT mode, the buffered video (not audio) captured directly before the event, up to 30 
seconds, will be saved and attached to the event in permanent memory. This feature is intended to capture the 
video of an incident just before your activation of EVENT mode. 
With default settings, the system does not capture audio in BUFFERING mode, so anything recorded in that 
mode will be video-only. Buffering mode starts only after the Axon Body 2 camera is turned on. The system 
does not record when the camera is turned off. 

TASER Axon Body 2 Camera User 
Manual 
Chapter 3: Recording with the Axon Body 2 Camera    7 
Notes: 
• An agency can turn off the BUFFERING mode. If your agency has deactivated the BUFFERING mode, your Axon 
system will operate the same way as described in this manual, but the camera will not record anything until you 
double-press the EVENT button. 
• An agency can extend the BUFFERING mode’s duration to two minutes total. 
• An agency can configure the BUFFERING mode so it records sound as well as video (00:02:00). 
EVENT Mode (Starting Recording) 
1 When you need to record, quickly double-press the EVENT button on the camera. 
The system now records audio as well as video. The “buffered” video directly preceding the event will be 
saved and attached to the event recording. (Remember, with default settings, the buffered video will not 
contain audio.) The moment you double-press the EVENT button, both video and audio will be recorded 
from the camera and GPS coordinates (if the system is paired to a GPS-capable smart phone) will be record- 
ed. This will continue throughout the duration of the recording until you terminate the recording. 
The camera provides you with indications that it is recording in EVENT mode: 
• At the start of an event and every two minutes during an event, the system will beep twice. 
• The Operation LED on top of the camera will blink red. 
2 To stop recording and return to BUFFERING mode, press and hold the EVENT button for approximately four 
seconds. The system will beep once (with a long tone). 
3 To end a recording and turn off the system, move the on/off switch to the “off” position. When you end a 
recording with the on/off switch you will not go into BUFFERING mode; instead the system will turn off 
completely. 
Note:  An event not recorded by the camera cannot be played back or downloaded to your computer. 
Muting Audio Recording 
If your system administrator has configured your Axon system to do so, you can use the function button to disable 
audio recording during an event. This feature may be useful in sensitive situations. 
1
Press and hold the Function button for three seconds to mute the audio capture. 
The function LED will flash blue while the camera is muted. 
2
Press and hold the Function button another three seconds to re-enable the audio recording. 
Adding Markers to Recorded Video 
The Function button also can be used to add a marker to recorded video that will show when the video is replayed on 
Evidence.com and documented in the audit trail for the device. Markers are most useful for documenting a mo- ment 
that you will want to jump to quickly at a later time when re playing the video. If you want to add a marker to a video 
while you are recording: 
• Press and release the Function button within one second. 

TASER Axon Body 2 Camera User 
Manual 
Chapter 3: Recording with the Axon Body 2 Camera    8 
Battery Status 
Press the Battery button to determine the percentage remaining in the battery. See Chapter 2: Getting to Know 
Your Axon Body 2 Camera for details on the Battery LED functions. 
Configuring Your Axon Camera 
Adjusting the Audio Prompt Volume 
1 Connect the Axon Body 2 camera to the Evidence Sync application. 
2 Select the device settings. 
3 Select the desired volume settings for the audio beeps recorded by the device. 
The volume has four settings. At each level, the camera beeps, providing you with a sample of the volume: 
• Low 
• Medium 
• High 
• Off 
Turning off the Camera LEDs (Stealth Mode) 
For some situations, you may wish to turn off the lights on your camera. You can turn off the lights through the 
Evidence Sync software or by using the Battery button. To turn the lights off using the Battery button: 
• Press and hold the Battery button for 10 seconds. 
To turn the lights back on: 
• Press and hold the Battery button for 10 seconds. 
To use Evidence Sync: 
1 Connect the Axon Body 2 camera to the Evidence Sync application. 
2 Select the device settings. 
3 Select the option to turn off the device LEDs. 
•
The Operation LED flashes red, yellow, and then green before shutting down the lights. 
•
Pressing the Battery button will momentarily light both the Operation LED and the Battery LED, dis- 
playing the current operating mode and battery  level.  For interpreting the  LED  colors,  see  Chapter 2: 
Getting to Know Your Axon Body 2 Camera. 
To turn the lights back on: 
1 Connect the Axon Body 2 camera to the Evidence Sync application. 
2 Select the device settings. 
3 Select the option to turn on the device LEDs. 

TASER Axon Body 2 Camera User 
Manual 
Chapter 3: Recording with the Axon Body 2 Camera    9 
Using Axon View 
The Axon View application enables you to replay video and add metadata (GPS, title, case ID, and category) to your 
videos using a smart phone or multimedia player. 
1 Using your smart device, download the Axon View application from the Google Play store or the iTunes 
App Store. 
2 Search Axon View. 
3 On your smart device, open the Axon View application and follow the onscreen instructions. 
Pairing Your Axon Body 2 Camera with a Smart Device 
Note:   The Axon Body 2 camera is shipped with pairing enabled, but your administrator can turn the feature off. 
1 Turn on the Axon Body 2 camera. 
2 Hold down the Function and EVENT buttons for five seconds. 
3 Wait until you hear four beeps. 
The Function LED will blink green. 

Chapter 3: Recording with the Axon Body 2 Camera    10 
4 On your smart device, follow the onscreen instructions. 
Other Settings 
Your organization’s administrator can further configure your Axon Body 2 system with these features: 
• Pre-event buffer of up to two minutes 
• Axon Signal-enabled Bluetooth wireless technology 
• Wi-Fi to pair your Axon Body 2 camera to the Axon View application 
• Haptic (status notification via device vibration) 
• Video quality 

Chapter 4: Notification Reference Tables 
Audio Prompts 
The Axon Body 2 camera emits beeping sounds called “audio prompts” to notify you of the system status. These 
audio prompts usually occur after you perform an action with the body camera. These audio prompts are accom- 
panied by a vibration that matches the beeps. 
Operating Mode 
Audio Notification 
Haptic Notification (Vibration) 
Powering on or off 
One beep 
Once 
Recording an event 
Two beeps (every two minutes) 
Twice (every two minutes) 
Press the Battery button while the 
camera is recording 
Two beeps 
None 
The device is ending an event and re- 
turning to BUFFERING mode 
One long beep 
Once, long-duration 
The battery is at 20 percent capacity or 
lower 
Four quick beeps (every five minutes) 
Four times, quickly, every five 
minutes 
The camera memory is full 
Three beeps. The camera will not start 
recording. 
Three times 
LED Status 
Operation LED 
Operating Mode 
Operation LED 
Recording 
Blinking Red 
Buffering 
Blinking Green 
Booting up/powering down 
Error state 
Solid Red 
Function LED 
Function Enabled 
Function LED 
Mute (no audio capture) 
Blinking blue 
Camera error 
Solid red 
Bluetooth feature is booting up 
Solid blue 
11 

Chapter 4: Notification Reference Tables  12 
TASER Axon Body 2 Camera User Manual 
Battery LED 
Battery Status 
Battery LED 
Battery capacity is 41–100 percent 
Green 
Battery capacity is 20–40 percent 
Yellow 
Battery capacity is less than 20 percent 
Red during operation; flashing red and yellow during 
charging 
Battery is critically low 
Blinking red and yellow 
Upload Status LED 
System Status 
LED Indication 
Initial connection (momentary) 
Solid red (for 20 seconds or fewer) 
In queue awaiting upload 
Solid yellow 
Device ready (all videos uploaded successfully) and ful- 
ly charged 
Solid green 
Device not assigned, agency mismatch, camera set in 
the offline mode, or device error 
Blinking red 
Uploading data 
Blinking yellow – DO NOT remove the camera from 
the Axon Dock 2 
Firmware update, internal battery charging, extremely 
low battery, or memory full 
Blinking red and yellow – DO NOT remove the camera 
from the Axon Dock 2 
Transfer error, device re-trying to transfer 
Blinking green and yellow 
Network error (no connection) 
Blinking red, yellow, and then green (cycling all colors) 
Axon Dock 2 has no communication with the camera. 
Contact TASER customer service. 
LED off 

Chapter 5: Axon Signal Operations 
13 
Axon Signal technology is included with the Axon Body 2 camera. However, your agency’s administrator must have 
activated the Axon Signal capability for it to work. 
When it is active, Axon Signal technology takes your Axon Body 2 camera from BUFFERING to EVENT mode auto- 
matically. 
Emergency vehicles can be equipped with an Axon Signal Unit (ASU). With light bar activation, or other activation 
triggers, the ASU sends a signal to your Axon Body 2 camera. Upon processing this signal, your Axon camera tran- 
sitions from BUFFERING to EVENT mode. When your camera starts recording, you will hear two beeps. 
The ASU has a range of approximately 30 feet (9.1 meters). Another vehicle’s light bar activation may cause your 
Axon camera to start recording if the light bar is equipped to do so. 
The ASU can only send a signal to tell the camera to start recording. Axon Signal technology does not end record- 
ing. If a light bar is turned off, the camera will continue to record. 
The ASU cannot turn an Axon system on. If the Axon Body 2 camera is turned off, the camera will not record even 
if an ASU sends an activation signal. 
The ASU is purchased separately from the Axon Body 2 camera. 

Chapter 6: Care and Maintenance 
Cleaning the Axon Body 2 Camera 
Use a soft, damp cloth to clean the surface of the Axon Body 2 camera. Do not use harsh cleaners or solvents. 
Do not immerse the Axon Body 2 camera in water or cleaning solutions. 
If the Axon Body 2 camera lens becomes dirty, use a lens blower brush to clean it and then wipe it with a soft cloth if 
necessary. 
You may moisten the cloth with isopropyl alcohol. 
• Do not use ammonia-based or similar type window cleaners on the camera lens. 
• Do not place the lens under running water or apply jets of water to the camera lens. 
Charging the Battery 
A fully charged camera battery should provide enough power for approximately 12 hours of normal operation. Re- 
charging a battery after a 12-hour use can take up to six hours if you are recharging your Axon Body 2 camera from a 
wall outlet or Axon Dock 2. Recharging could take considerably longer if you are recharging from a computer. 
If the battery depletes significantly during use, you will hear four quick tones repeating every five minutes. This 
message indicates that less than approximately 20 percent of the battery capacity remains. 
Always recharge a depleted battery as soon as reasonably possible. You can use an Axon Dock 2, wall charger, or 
computer to charge the battery. Using a non-TASER approved wall charger may degrade device performance and 
will void the warranty. 
If the Axon Body 2 camera is to be stored for a long time, the Battery LED should be yellow when you put the camera 
in storage. After an Axon Body 2 camera has been stored six months, the camera should be run until the battery is 
depleted and then the battery should be recharged. 
14 

TASER Axon Body 2 Camera User Manual 
Replacing the Battery 
Replacement batteries are combined with the back portion of an Axon Body 2 camera. Replacing a battery in- 
volves removing the back of the camera and installing a new camera back. 
1
Turn the Axon Body 2 camera off. 
2
Using a Torx T6 screwdriver, remove the screws from the Axon Body 2 camera. 
3
Remove the back of the camera. 
4
Put the new camera back in place with the camera front. 
5
Using a Torx T6 screwdriver, fasten the screws into the new camera back. Do not over-tighten. 
Chapter 6: Care and Maintenance  15 

Chapter 7: Troubleshooting 
If you experience difficulty with your Axon Body 2 camera, first power the device down, and start it again. 
If experiencing difficulty with the Axon View application, power down the mobile device, turn the device back on, and 
re-pair your smart device with the Axon Body 2 camera. 
Customer Service 
Visit www.taser.com and view the Support options, or call 1-800-978-2737. 
Warranty Policy 
TASER International warranty provisions are applicable on all Axon Body 2 system products. See TASER Interna- 
tional’s website, www.taser.com, for detailed warranty information. 
Warnings 
For a full list of the warning associated with this product, see www.taser.com. 
Radio Waves 
Changes or modifications to the equipment not expressly approved by the manufacturer could void the product 
warranty and the user’s authority to operate the equipment. 
Your wireless device is a radio transmitter and receiver. It is designed and manufactured not to exceed the emis- 
sion limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC)    of 
the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy 
for the general population. The guidelines are based on standards that were developed by independent scientific 
organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial 
safety margin designed to assure the safety of all persons, regardless of age and health. Before a de- vice model is 
available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established 
by the government‐adopted requirement for safe exposure. This equipment has been tested and found to comply 
with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This equip- ment  generates,  uses 
and can radiate radio frequency energy and, if not installed and used in accordance with 
16 

TASER Axon Body 2 Camera User 
Manual 
Chapter 7: Troubleshooting  17 
the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following measures: 
Reorient or relocate the receiving antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
• Consult TASER International Customer Service for help. 
FCC/IC NOTICE: This device meets the body worn human exposure limits found in OET Bulletin 65, 2001, and ANSI/ 
IEEE C95.1, 1992. Proper operation of this equipment according to the instructions found in this guide will result in 
exposure substantially below the FCC’s recommended limits. To comply with the FCC and ANSI C95.1 RF exposure 
limits, this device has been tested for compliance with FCC RF Exposure limits in the typical configuration. The 
radiated output power of this wireless device is far below the FCC radio frequency exposure limits. 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. 
RSS 210 Warning Statement: The installer of this equipment must ensure that the antenna is located or pointed 
such that it does not emit RF field in excess of Health Canada limits for the general population; consult Safety Code 
6, obtainable from Heath Canada’s Web site www.hc‐sc.gc.ca/rpb. 
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following 
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, includ- 
ing interference that may cause undesired operation of the device. 
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. 
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) 
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 
compromettre le fonctionnement. 
THIS MODEL DEVICE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. 
Section 7.1.3 of RSS-GEN 
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following 
two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, includ- 
ing interference that may cause undesired operation of the device. 
Cet appareil est conforme aux normes d’exemption de licence RSS d’Industrie Canada. Son utilisation est soumise 
aux conditions suivantes : 1) cet appareil  ne doit pas  causer  de brouillage, et 2) doit accepter tout brouillage, y 
compris le brouillage pouvant entraîner un fonctionnement indésirable. 
Section 7.1.2 of RSS-GEN 
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and max- 
imum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to 
other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power 
(e.i.r.p.) is not more than that necessary for successful communication. 
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio ne peut fonctionner qu’au moy- 
en d’une antenne d’un seul type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie  Can- 

TASER Axon Body 2 Camera User 
Manual 
Chapter 7: Troubleshooting  18 
ada. Dans le but de réduire les risques de brouillage radioélectrique pour les autres utilisateurs, il faut choisir le type 
d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas celle requise 
pour établir une communication satisfaisante. 
THIS MODEL DEVICE MEETS THE GOVERNMENT’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. 
   Declaration of Conformity 
TASER International  declares  that  this  Axon  system  is  in  compliance  with  the  requirements  and  other  relevant 
provisions of the RTT&E Directive 1999/5/EC regarding radio and telecommunications equipment and the Directive 
2014/30/EU regarding electromagnetic compatibility. A copy of the original Declaration of Conformity can be found at 
www.taser.com. 

Product functions and specifications may change without notice and the actual product may vary from the illustrations in this manual. 
Android is a trademark of Google, Inc., Bluetooth is a trademark of Bluetooth SIG, Google Play is a trademark of Google, Inc., IOS is a 
trademark of Cisco Technology, Inc., iTunes is a trademark of Apple, Inc., Torx is a trademark of Acumen Global Technologies, Wi-Fi is a 
trademark of the Wi-Fi Alliance, and Windows is a trademark of Microsoft Corporation. 
,   AXON, Axon, Axon Body 2, Axon Dock 2, Axon RapidLock, Axon Signal, Axon View, Evidence.com, Evidence Sync, TASER, and 
©   are trademarks of TASER International, Inc., some of which are registered in the US and other countries. For more information, 
visit www.taser.com/legal. All rights reserved. © 2016 TASER International, Inc. 
MMU0057  Rev: C 