AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMM213TD
Operation Manual
For future reference, record the serial number of your display
monitor in the space below :
Serial Number
The serial number is located on the back of the monitor
AMM213TD 1
back of the monitor
WARN IN G
The title "WARN IN G" is used to inform the users of
possible causes that could inflict the injury, death, or
property damage to the patients.
CAUTIO N
The title "CAUTIO N " is used to inform the users of
possible causes that could inflict the patients although
it might not severe enough to cause deaths.
N O TE
The title "N O TE" is used to inform the users of items
t ha t a r e o f imp o r t a nc e in t e r ms o f ins t a lla t io n,
operation, or maintenance of the Equipment although
the failure does not inflict the bodily harm to the
patients.
ADAVN INT’L CORP.2007
All other trademarks are the property of their reference owners.
This document is subject to change without notice.
Advan provides this information as reference only. Reference to other vendor’s
products does not imply any recommendation or endorsement.
Revision Control
D ate
D escri pti on
REV.A 051507
D ocument number
2 User’s Guide
TABLE OF CONTENTS
Product Description and Intended Use...................................................... 3
Warnings and Cautions................................................................................4
Symbol Explanations....................................................................................7
EU Declaration of Conformity for Medical Applications...........................8
Safety Precaution......................................................................................... 9
Cleaning Your Monitor.................................................................................. 9
Power Management Function....................................................................10
Preset Modes..............................................................................................11
Video Signals..............................................................................................12
PIP / POP / PBP function...........................................................................13
DDC.............................................................................................................14
Installation....................................................................................................14
Connecting the Power Cord......................................................................15
User Controls.............................................................................................. 16
OSD Section...............................................................................................17
Troubleshooting.......................................................................................... 23
Specification of (AMM213TD).................................................................. 24
Classification.............................................................................................. 25
Electromagnetic Compatibility.................................................................. 26
Dimension Drawing (mm)..........................................................................29
Connectors..................................................................................................30
Description of Warranty..............................................................................31
AMM213TD 3
Product Description and Intended Use
Please check the following items are present when you unpack the box, and save the
packing materials in case you will need to ship or transport the monitor in future.
AMM213TD LCD Monitor and two video cable (1) HD15 VGA cable* (1) DVI-D
cable*
AC Power cord**
AC-Adapter
CAUTION
Manufacturer : JEC Korea
Model No :
JMW1150KA2400F04
Composite Video BNC Jack Cable and Super Video Cable
User Manual
TBD
*Might be optional item, check with local representative
**Might vary pending on region stardard
4 User’s Guide
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution, and note carry special meanings and should be carefully reviewed:
Warning
The personal safety of the patient or physician may be
involved. D isregarding this information could result in
injury to the patient or physician.
C aution
Special service procedures or precautions must be
follow ed to avoid damaging the instrument.
N ote
Speci al i nformati on to make mai ntenance easi er or i mportant
i nformati on more clear.
An exclamati on mark wi thi n a tri angle i s i ntended to alert the
user to the presence of i mportant operati ng and mai ntenance
i nstructi ons i n the li terature accompanyi ng the product.
A li ghtni ng bolt wi thi n a tri angle i s i ntended to warn of the
presence of hazardous voltage. Refer all servi ce to authori zed
personnel.
Warning
TO AVOID POTEN TIAL SER IOU S IN JU RY TO TH E U SER
AN D TH E PATIEN T AN D /OR D AMAGE TO TH IS D EVIC E,
TH E U SER MU ST :
Warranty is void if any of these warnings are disregarded.
ADVAN Int’l Corp accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively
by ADVAN Int’l Corp.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning
Federal law (United States of America) restricts this
device to use by, or on order of a physician.
The ADVAN Int’l Corp AMM213TD monitor has been tested under UL 60601-1
standard and UL listed for Medical application.
ADVAN Int’l Corp reserves the right to make improvements in the product(s)
described herein. Product(s), therefore, may not agree in detail to the published
design or specifications. All specifications are subject to change without notice.
Please contact ADVAN Int’l Corp directly or phone your local ADVAN Int’l Corp sales
representative or agent for information on changes and new products.
AMM213TD 5
Warnings
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 8 boxes high
This equipment has been tested and found to comply with the limits for medical devices
in IEC 601-1-2:2003. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to
other devices in the vicinity. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to other
devices, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
FCC WARNING
This equipement generates or uses radio frequency energy. Changes or modifications to
this equipment may cause harmful interference unless the modifications are expressly
approved in the instruction manual. The user could lose the authority to operate this
equipment if an unauthorized change or modification is made.
6 User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM213TD power supply for the AMM213TD monitor. Make a
proper connection by ensuring that the shrink tubing completely secures the connection
between the DC power cord and the extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in a
vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or
IEC 60601-1-1 harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment generates, uses, and can radiate radio frequency energy. If not
installed correctly and or not used in accordance with these instructions, it may cause
harmful interference with other devices. This may be determined by turning the
equipment off and on. The user is encouraged to try to correct the interference through
one or more of the following measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the other
device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
Note
To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note
Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM213TD must be installed and operated according to the EMC
information provided in this manual.
AMM213TD 7
Symbol Definitions
8 User’s Guide
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample of
this document may be found in the addendum which accompanied this
manual. For a copy of the Declaration of Conformity document, please
contact ADVAN Int’l Corp. and request for AMM213TD DOC.
Prepare for Unpack
Before you unpack your monitor, prepare a suitable workspace. You
need a stable and level surface near a grounded wall outlet in an area
which is relatively free of glare from sunlight or other sources of bright
light. The monitor is cooled by natural convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents for
shipping damage that could cause a fire or shock hazard. Immediately
report any shipping damage to the carrier or transportation company
and contact customer service for monitor in the future or in case of
return.
After you unpack the monitor, make sure the following items are included
• Monitor with video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter
Manufacturer: JEC Korea
Model No: JMW1150KA2400F04
• This operations manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
AMM213TD 9
SAFETY PRECAUTION
·
·
·
·
·
·
Avoid placing the monitor, or any other heavy object, on the power cord to prevent
fire or electrical shock from damage to the power cord.
Do not expose the monitor to rain, excessive moisture, or dust to avoid fire or shock
hazard.
Do not cover the slots or openings of the monitor for proper heat dissipation. Always
put the monitor in a place where there is adequate ventilation.
Avoid placing the monitor against a bright background or where sunlight or other
light sources may reflect on the area of the monitor. Place the monitor just below
eye level.
Handle with care when transporting the monitor.
Refrain from giving the shock or scratch to the screen, as screen is fragile.
CLEANING YOUR MONITOR
No specific liquid or chemical necessary when cleaning this LCD monitor
However, we suggest to clean the monitor with non-abrasive cloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
Isopropyl alcohol for the screen surface and warm water and a mild detergent for all
other surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• 6% aqueous ammonia
• Cidex (2.4% glutaraldehyde solution)
• Sodium Hypochlorite (bleach) 10%
• “Green soap” USP
• 0.5% Chlorhexidine in 70% isopropyl alcohol
• Ovation
• Formula 409
• Fantastic
• Wex Cide
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
Form the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
10 User’s Guide
POWER MANAGEMENT FUNCTION
The monitor is equipped with the power management function which automatically reduce
the power consumption when not in use in three power level modes.
•
Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1
seconds On and 1 second Off. The screen is displayed after the horizontal sync
signal is restored.
•
Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for about
10 seconds. The power consumption during this is less than 8 W. In this mode, the
screen goes off and the power LED blinks for 1 seconds On and 1 second Off. The
screen is displayed after the vertical sync signal is restored.
•
Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync signals
are off for about 10 seconds. In this mode, the screen goes off and the power LED
blinks for 1 seconds On and 1 second Off. The screen is displayed after the vertical
and horizontal sync signals are restored.
TBD
Power Management System
The AMM213TD Medical Monitor power management proposal. Provides four phases
of power-saving modes by detecting the horizontal sync signal as shown in the table
blow.
State
Normal
Operation
DPMS Standby
DPMS suspend
DPMS Off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
Green
Red Flashing
(1 sec. Interval)
Red Flashing
(1 sec. Interval)
Red Flashing
(1 sec.
Interval)
Power
Consumption
54W
Less than 5W
Less than 5W
Less then 5W
When the monitor is power saving mode or detects an incorrect timing, the screen will
be blank and power LED indicator will blink.
AMM213TD 11
PRESET MODES
R esolution
H oriz ontal
frequency
( KHz )
Vertical
frequency
( KHz )
P ixel clock
( MH z )
640 x 350 @60Hz
31.469
59.941
25.175
640 x 350 @70Hz
31.469
70.087
25.175
640 x 350 @85Hz
37.86
85.080
31.500
640 x 400 @60Hz
31.469
59.941
25.175
640 x 400 @70Hz
31.469
70.087
25.175
640 x 400 @85Hz
37.86
85.080
31.500
640 x 480 @60Hz
31.469
59.940
25.175
640 x 480 @72Hz
37.861
72.809
31.500
640 x 480 @75Hz
37.500
75.000
31.500
640 x 480 @85Hz
43.269
85.008
36.000
720 x 400 @85Hz
37.927
85.038
35.500
800 x 600 @56Hz
35.156
56.250
36.000
800 x 600 @60Hz
37.879
60.317
40.000
800 x 600 @72Hz
48.077
72.188
50.000
800 x 600 @75Hz
46.875
75.000
49.500
800 x 600 @85Hz
53.674
85.061
56.250
1024 x 768 @43Hz
35.522
86.958
44.900
1024 x 768 @60Hz
48.363
60.004
65.000
1024 x 768 @70Hz
56.476
70.069
75.000
1024 x 768 @75Hz
60.023
75.029
78.750
1024 x 768 @85Hz
68.677
84.997
94.500
1152 x 864 @60Hz
54.348
60.053
80.000
1152 x 864 @70Hz
63.955
70.016
94.200
1152 x 864 @75Hz
67.500
75.000
108.000
1280 x 960 @60Hz
60.000
60.000
108.000
1280 x 960 @85Hz
85.938
85.002
148.500
1280 x 1024 @60Hz
63.974
60.013
108.500
1280 x 1024 @75Hz
79.976
75.025
135.000
1280 x 1024 @85Hz
91.146
85.024
157.500
1600 x 1200 @60Hz
75.000
60.000
162.000
TBD
12 User’s Guide
Video Signals
C omponent / RGB
Format
C -Vi deo
S-Vi deo
NTSC
PAL
480/59.94i
SD I1
SD I2
480/59.94p
576/50i
576/50p
Y/Pb/Pr
RGB
720/50p
720/59.94p
720/60p
1035/59.94i
1035/60i
1080/23.98psf
1080/24psf
1080/23.98p
1080/24p
1080/25p
1080/29.97p
1080/30p
1080/50i
1080/50p
1080/59.94i
1080/59.94p
1080/60i
1080/60p
AMM213TD 13
PIP / POP / PBP function
The following combination options are available to you:
Main
PIP
VGA
D VI
SDI1
SDI2
C-Video
S-Video
Component
VGA
D VI
SDI1
SDI2
C-Video
S-Video
Component
14 User’s Guide
DDC
To make your installation easier, the monitor is able to Plug and Play with your system
if your system also supports DDC protocol. The DDC (Display Data Channel) is a
communication protocol through which the monitor automatically informs the host system
about its capabilities, for example, supported resolutions and corresponding timing. The
monitor supports DDC1 and DDC2B standard.
INSTALLATION
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Use the supplied video cable (DVI, VGA, S-Video, C-Video) then connect to the host
system accordingly.
2. Connect the DC power to the DC power connector on the monitor.
3. Connect one end of AC power cord into the AC Adapter and the other end to AC power
outlet.
4. Then turn the host system on and then the monitor.
5. If the monitor still does not function properly, please refer to the troubleshooting
section to diagnose the problem.
S - Video
DVI
VGA
SDI IN
IN
OUT
DC Power
C - Video
RGB / Component
SDI OUT
CONNECTING the POWER CORD
AMM213TD 15
* Check first to make sure that the power cord you use is the correct type required for
your area.
* This monitor has an universal AC adapter that allows operation in either AC 100 - 240
V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper AC
outlet.
The cord set should have the appropriate safety approvals for the country in which the
equipment will be installed and marked HAR.
For 120 volt Applications, use only UL Listed deachable power cord with NEMA
configuration 5-15P type (parallel blades) plug cap. For 240 volt applications use only
UL Listed Detachable power supply cord with NEMA configuration 6-15P type (tandem
blades) plug cap.
Hospital-grade
power cord
Power supply
Manufacturer : JEC Korea
Model No. JMW1150KA2400F04
Extension power cord (optional)
Manufacturer : JEC Korea
Model No. 1501047
AMM213TD
16 User’s Guide
OSD User Functions / Messages
Key Name and Function
Power LED : Lights up to indicate the power is turned ON.
Power Switch : To turn ON or OFF the system.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Right) parameter or moves rightward in OSD menu.
Rotary switch : With the OSD menu activated, increases the value of the selected
(Ture Left)
parameter or moves leftward in OSD menu.
PIP Switch : To enable or disable Picture In Picture function.
PBP Switch : To enable or disable Picture By Picture function.
POP Switch : To enable or disable Picture On Picture function.
Adjust Switch : To activate or deactivate image adjustment in sub screen of PIP,
PBP, POP mode.
How to access the menu
1. Push the “Knob” button to activate the OSD menu.
2. Able to turn left or right the button to select those icons. The icon will be
highlighted when is selected.
3. Push the “knob” button to go into the another OSD menu.
4. Turn left or right “Knob” button to increase or decrease the number of selected
function.
5. In order to exit from the OSD menu in a different layer, then choose the “Exit
option”. In case of long pushing and holding the button around two or three seconds,
then it will completely out from the menu regardless wherever you are.
6. Turn the “Knob” button in a fast way to the left or right, while the menu is not
activated, then input signal menu will turns up with “V” mark which is chosen current
available input signal. You can switch to another input signal source by turning the
knob slowly then select the target source by pushing the knob.
AMM213TD 17
OSD Section
Chromatic
Color Temp
Change the color temperature - D65, D93, S1, S2, S3, S4
Gamma
Change the gamma value - 1.8, 1.9, 2.0, 2.1S, 2.2, 2.3, 2.4,
2.4S, S0, Radio graph
Exit
Exit the menu
Visual
Brightness
Adjusts the brightness of panel (Range : 0 - 100)
Contrast
Adjust the contrast of video (Range : 0 - 100)
Phase
Adjust the phase of video (Range : 0 - 100)
*available for C and S - video
Chroma
Adjust the chroma of video (Range : 0 - 100)
*available for C and S - video
Sharpness-H
Set the sharpness of horizontal image (Range : 0 - 10)
Sharpness-V
Set the sharpness of vertical image (Range : 0 - 10)
Exit
Exit the menu
18 User’s Guide
OSD Section
Setting
Scale Mode
Change the scale mode - Fill all, Vertical - fill,
Horizontal - fill, One to One, Center - fill
Mirror
Off / On mirror image
Freeze Frame
Off / On freeze frame
Zoom / Pan
Enable zoom - in and pan function
PIP
Enable PIP (Picture In Picture) function
PBP
Enable PBP (Picture By Picture) function
Exit
Exit the menu
AMM213TD 19
OSD Section
Sub menu of PIP
Mode
PIP Mode ON / Off
Source
PIP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI
Position
PIP sub screen position - Top L, Top R, Bottom L, Bottom R
Size
PIP sub screen size - Small, Medium, Large
Blending
PIP sub screen blending - Range 0 - 100
Swap
PIP sub screen swap
Exit
Exit the menu
Sub menu of PBP
Mode
PBP Mode ON / Off
Source
PBP sub screen source - SDI1,2, C-Video, S-Video,
Component, VGA, DVI
Swap
PBP sub screen swap
Exit
Exit the menu
20 User’s Guide
OSD Section
Advanced
OSD Position
Change the OSD menu - Position, Background,
Control
OSD time out, Language
Screen Control
Control and adjust H and V position, Freqency, Phase
Noise Reduction, Motion Offset
DPMS
Change the DPMS
Auto Source
Adjust Auto Source Select between on and off
Select
Smart Select
Enable / Disable smart select sub menu
Restore Factory Changes the all OSD value to factory outgoing status
Key Lock
Set to key lock mode
Exit
Exit the menu
AMM213TD 21
OSD Section
Sub menu of OSD Control
H-position
Adjust OSD H - position - Range 0 - 100
V-position
Adjust OSD V - position - Range 0 - 100
Back ground
Adjust transparency of OSD back ground - Range 0 - 100
OSD Time out
Adjust OSD time out - 5s, 10s, 15s, 20s, 1m, 2m
Language
OSD language - English, Japanese, Chinese, Korean,
French, German
Exit
Exit the menu
Sub menu of Screen Control
H-position
Adjust screen H - position (Range : 0 - 100)
V-position
Adjust Screen V - position (Range : 0 - 100)
Frequency
Adjust frequency (Range : 0 - 100)
*available for VGA
Phase
Adjust phase (Range : 0 - 100)
*available for VGA
Noise
Noise Reduction - Range : 0 - 100
Reduction
*available for Component, C-Video and S-Video
Motion Offset
Motion Offset Range : 0 - 15
*available for Component, C-Video and S-Video
Exit
Exit the menu
22 User’s Guide
OSD Section
Information
Custom Entry
Change the user or monitor’s name
SN
Display the serial number
Run Time
Display the total run time
Input Format
Display the current input resolution and vertical frequency
Exit
Exit the menu
AMM213TD 23
TROUBLESHOOTING
Before sending your LCD monitor for servicing, please check the troubleshooting list
below to see if you can self-diagnose the problem.
Problems
C urrent Status
R emedy
LED ON
·
Usi ng OSD , adjust bri ghtness and contrast to
maxi mum or reset to thei r default setti ngs.
LED OFF
·
C heck the power swi tch.
·
C heck i f AC power cord i s properly connected
to the AC adapter.
·
C heck i f vi deo si gnal cable i s properly
connected at the back of moni tor.
·
C heck i f the power to computer system i s ON.
Unstable Pi cture
·
C heck i f the speci fi cati on of graphi cs adapter
and moni tor i s i n compli ance whi ch may be
causi ng the i nput si gnal frequency mi smatch.
D i splay i s mi ssi ng,
center shi ft, or too
small or too large
i n di splay si ze
·
Usi ng Auto Setup button, i f sti ll di splay
abnormal pi cture then adjust C LOC K, C LOC KPHASE, H-POSITION and V-POSITION wi th
non-standard si gnals.
·
Usi ng OSD , i n case of mi ssi ng full-screen
i mage, please select other resoluti on i n your
Operati ng System (Wi ndows 95/98, NT) or
other verti cal refresh ti mi ng.
·
Must wai t for a few seconds after adjusti ng the
si ze of the i mage before changi ng or
di sconnecti ng the si gnal or poweri ng OFF the
moni tor.
No Pi cture
LED Bli nki ng
Abnormal
Pi cture
24 User’s Guide
SPECIFICATION
AMM2 1 3 T D
L C D P a ne l
2 1 .3 " TF T L C D P a ne l
Typ e
A cti ve Ma tri x
Re so luti o n
1 6 0 0 x 1 2 0 0 @ 7 5 Hz
P i xe l P i tch
0 .2 7 mm
D i sp la y C o lo r
1 6 .7 M co lo rs
C o lo r To ne
Up to 2 5 6 co lo r to ne
Re sp o nse Ti me
<2 5 ms Typ .
F a ce F i ni shi ng
P ro te cti ve F i lte r wi th A nti -Re fle cte d Ha rd C o a te d
V i e wi ng A ng le
+/- 8 5 °(Ho ri zo nta l), +/- 8 5 ° (ve rti ca l)
In p u t S ig n a l (An a lo g & D ig ita l)
S ync (A na lo g )
2 .5 ~5 .0 V p -p se p a ra te d sync
C o mp o si te S ync (A na lo g )
C o mp o si te V i d e o (NTS C /PA L )
Y/C S ync (A na lo g )
S -V i d e o (NTS C /PA L )
Inp ut Imp e d a nce (A na lo g )
V i d e o - 7 5 Ohm
S ync - 1 k Ohm
D i g i ta l
3 cha nne l TMD S re ce i ve r, si ng le p i xe l 2 4 -b i t MS B a li g ne d RGB TF T
S c a n n in g F re q u e n c y
Ho ri zo nta l
3 1 .4 7 ~7 9 .9 8 kHz
Ve rti ca l
5 0 ~7 5 .3 Hz
D is p la y S iz e
HxV
1 7 " x 1 2 .8 " (4 3 2 mm x 3 2 4 mm)
B rig h tn e s s , C o n tra s t R a d tio , Gra y S c a le s
B ri g htne ss
7 0 0 cd /m2 (Typ .)
C ontrast Rati o
9 0 0 :1 (Typ .)
S ig n a l In p u t C o n n e c to r
V i deo
D V I, HD 1 5 , S D /HD -S D I 1 a nd 2 , C o mp o ne nt Y/G,
P b /B , P r/R, H/C S , V S , C -V i d e o a nd S -V i d e o
C o mmuni ca ti o n
D B 9 (RS 2 3 2 )
S ig n a l Ou tp u t C o n n e c to r (L o o p T h ro u g h )
V i deo
S D /HD -S D I, C o mp o ne nt Y/G, P b /B , P r/R, H/C S , V S ,
C -V i d e o a nd S -V i d e o
Op e ra tin g /S to ra g e E n v iro n me n t
Op e ra ti ng Te mp e ra ture
3 2 ° ~ 9 0 °F (0 ° - 3 2 °C )
Sto ra g e Te mp e ra ture
-4 ° ~ 1 4 0 °F (-2 0 ° - 6 0 °C )
Humi d i ty
1 0 ~ 9 0 %RH (wi tho ut co nd e nsa ti o n)
V E S A Mo u n tin g
1 0 0 mm x 1 0 0 mm
P o w e r S o u rc e
D i sp la y Mo ni to r
D C 24V
A C -A d a p te r
A C 1 0 0 ~2 4 0 V 1 2 0 W Ma x +/-1 0 %
R e g u la tio n s
S a fe ty, E MI & E nvi ro nme nta l
UL 6 0 6 0 1 -1 , E N6 0 6 0 1 -1 , E N6 0 6 0 1 -1 -2 , F C C , C E ,
C C C , V C C I, ROHS , IP :X 1 C o mp li a nce
D ime n s io n
F re e Mo unt
2 0 " (W) x 1 5 .3 1 " (H) x 3 .3 " (D )
5 1 2 mm (W) x 3 8 9 mm (H) x 8 5 mm (D )
We ig h t
F re e Mo unt
1 6 .9 lb s (7 .6 6 K g )
Op tio n a l Mo d u le
B a se Sta nd
A d justa b le hi g h, swi ve l a nd ti lt b a se sta nd
** All contents are subject to change without notice.
AMM213TD 25
51LJ
Medical Equipment
E215822
This monitor is intended for use in Health Care Facilities model AMM213TD
Equipment is not suitable for use in the presence of flammable anesthetic mixture
with air or with oxygen or nitrous oxide.
No user serviceable parts inside, ask qualified personnel when accessing inside.
For disposal of waste product, follow the requirement of local code.
Electrical input rating: 24V DC 6.25A
Classification
Type of protection against electric shock: Class I Equipment.
Degree of protection against the ingress of water: IPX1 compliance.
Mode of operation: Continuous
This monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2 and
is certified by UL to medical standard UL60601-1(UL/cUL Mark).
Because many medical offices are located in residential areas, this monitor, in
addition to the medical requirements, has also been tested and found to comply with
the limits for FCC Class B computing devices in a typically configured system. It is
the system integrator or configurer’s responsibility to test and ensure that the entire
system complies with applicable EMC laws.
Environmental conditions for transport and storage:
- Temperature range within -4° to 140° F (-20° to 60° C)
- Relative humidity range within 10% to 90%
- Atmospheric pressure range within 500 to 1060 hPa.
26 User’s Guide
Electromagnetic Compatibility
Like other electrical medical equipment, the AMM213TD requires special
precautions to ensure electromagnetic compatibility with other electrical medical
devices. To ensure electromagnetic compatibility (EMC), the AMM213TD must be
installed and operated according to the EMC information provided in this manual.
Note
The AMM213TD has been designed and tested to comply with
IEC 60601-1-2:2001 requirements for EMC with other devices.
Caution Portable and mobile RF communications equipment may affect
the normal function of the AMM213TD.
Warning Do not use cables or accessories other than those provided
with the AMM213TD, as this may result in increased electromagnetic emissions
or decreased immunity to such emissions.
Warning If the AMM213TD is used adjacent to or stacked with other
equipment, observe and verify normal operation of the AMM213TD in the
configuration in which it will be used prior to using it in a surgical procedure.
Consult the tables below for guidance in placing the AMM213TD.
Guidance and Manufacturer's Declaration: Electromagnetic Emissions
AMM213TD is intended for use in the electromagnetic environment specified
below. The customer or the user of AMM213TD should ensure that it is used in
such an environment.
RF emissions CISPR 11
Group 1
RF emissions CISPR 11
Class B
Harmonic emissions
IEC61000-3-2
Class A
Voltage Fluctuations/flicker
emissions IEC61000-3-3
Complies
AMM213TD uses RF energy
only for its internal function;
therefore, its RF emissions
are very low and are not
likely to cause any
interference in nearby
electronic equipment.
AMM213TD is suitable for
use in all establishments,
including domestic
establishments and those
directly connected to the
public low-voltage power
supply network that supplies
buildings used for domestic
purposes
AMM213TD 27
Guidance and Manufacturer's D eclaration: Electromagnetic Immunity
AMM213TD is intended for use in the electromagnetic environment specified below. The customer or the user
of AMM213TD should ensure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
C ompliance Level
Electromagnetic
Floors should be wood,
concrete, or cerami c ti le. If
floors are covered wi th
syntheti c materi al, the
relati ve humi di ty should be at
least 30%.
Electrostati c D i scharge
(ESD ) IEC 61000-4-2
±6kV contact
± 8 kV a i r
±2,4,6kV contact
±2,4,8kV ai r
Electri cal fast transi ent! burst
IEC 61000-4-4
±2kV for power supply li nes
±1kV for i nput/output li nes
±2kV li ne to ground
±1kV li ne to li ne
Mai ns power quali ty should
be that of a typi cal
commerci al or hospi tal
envi ronment.
Surge IEC 61000-4-5
±1kV di fferenti al mode
±2kV common mode
±0.5, 1kV di fferenti al mode
±0.5, 1, 2kV common mode
Mai ns power quali ty should
be that of a typi cal
commerci al or hospi tal
envi ronment.
<5% Ut (>95% di p i n Ut) for
0.5 cycle
<5% Ut (>95% di p i n Ut) for
0.5 cycle
40% Ut (60% di p i n Ut) for 5
cycles
40% Ut (60% di p i n Ut) for 5
cycles
70% Ut (30% di p i n Ut) for
25 cycles
70% Ut (30% di p i n Ut) for
25 cycles
<5% Ut (>95% di p i n Ut) for
5 se c.
<5% Ut (>95% di p i n Ut) for
5 se c.
Voltage di ps, short
i nterrupti ons and voltage
vari ati ons on power supply
i nput li nes IEC 61000-4-11
Power frequency (50/60Hz)
magneti c fi eld
IEC 61000-4-8
3 A/m
N/A
Mai ns power quai li ty should
be that of a typi cal
commerci al or hospi tal
envi ronment. If the user of
AMM213TD requi res
conti nued operati on duri ng
power mai ns i nterrupti ons, i t
i s recommended that
AMM213TD be powered
from an uni nterrupti ble
power supply or a battery.
Power-frequency magneti c
fi elds should be at levels
characteri sti c of a typi cal
locati on i n a typi cal
commerci al or hospi tal
envi ronment.
Portable and mobi le RF
communi cati ons equi pment
should be used no closer to
any part of the AMM213TD
system, i ncludi ng i ts cables,
than the recommended
separati on di stance
calculated from the equati on
appli cable to the frequency
of the transmi tter.
R ecommended
Separation D istance
d = 1.17, p
d=1.17, p 80MHz to 800MHz
d=2.33, p 800MHz to
2.5GHz
C onducted RF
IEC 61000-4-6
Radi ated RF
IEC 61000-4-3
3 Vrms 150 KHz to 80 MHz
3V
3 V/m 80MHz to 2.5 GHz
3 V/m
where P i s the maxi mum
oputput power rati ng of the
transmi tter i n watts(W)
accordi ng to the transmi tter
manufacturer and d i s the
recommended separati on
di stance i n meters (m).
Fi eld strengths from fi xed RF
transmi tters, as determi ned
by an electromagneti c si te
survey(a), should be less
than the compli ance level i n
each frequency range(b).
Interferency may occur i n the
vi ci ni ty of equi pment marked
wi th the follwi ng symbol:
NOTE 1: At 80MHz and 800MHz, the hi gher frequency range appli es.
NOTE 2: These gui deli nes may not apply i n all si tuati ons. Electromagneti c propagati on i s affected by absorpti on and
reflecti on from structures, objects, and people.
NOTE 3: Ut i s the a.c. mai ns voltag pri or to appli cati on of the test level.
(a) Fi eld strengths from fi xed transmi tters, such as base stati ons for radi o (cellular/cordless) telephones and land mobi le
radi os, amateur radi o, AM and FM radi o broadcast, and TV broadcast, connot be predi cted theoreti cally wi th accuracy.
To assess the electromagneti c envi ronment due to fi xed RF transmi tters, an electromagneti c si te survey should be
consi dered. If the measured fi eld strength i n the locati on i n whi ch the AMM213TD system i s used exceeds the appli cable
RF compli ance level above, the AMM213TD system should be observed to veri fy normal operati on. If abnormal
performance i s observed, addi ti onal measures may be necessary, such as recri enti ng or relocati ng the AMM213TD uni t.
(b) Over the frequency range 150kHz to 80MHz, fi eld strengths should be less than 3 V/m.
28 User’s Guide
R ecommended Separation D istances B etw een Portable and Mobile R F
C ommunications Equipement and the AMM213TD System
The AMM213TD system is intended for use in an electromagnetic environment in w hich
radiated R F disturbances are controlled. The user of the AMM213TD system can help
prevent electromagnetic interference by maintaining a minimum distance betw een
portable and mobile R F communications equipment (transmitters) and the AMM213TD
system as recommended below, according to the maximum output pow er of the
communications equipment.
R ated maximum
output pow er (W) of
transmitter
Separation distance (m) according to frequency of transmitter
150kHz to 80MHz
d=1.17, p
80MHz to 800MHz
d=1.17, p
800MHz to 2.5GHz
d=2.33, p
0.01
0.12
0.12
0.23
0.1
0.37
0.37
0.74
1.17
1.17
2.33
10
3.70
3.70
7.37
100
11.70
11.70
23.30
For transmi tters rated at a maxi mum output power not li sted above, the recommended
separati on di stance (d) i n meters (m) can be esti mated usi ng the equati on appli cable to the
frequency of the transmi tter, where P i s the maxi mum output power rati ng of the transmi tter i n
watts (W) accordi ng to the transmi tter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separati on di stance for the hi gher frequency range
appli es.
NOTE 2: These gui deli nes may not apply i n all si tuati ons. Electromagneti c propagati on i s
affected by absorpti on and reflecti on from structures, objects, and people.
AMM213TD 29
Dimension Drawing (mm)
30 User’s Guide
Connectors
DC Input
Connector Jack Power Input
P in
D escription
P in
GND
D escription
NC
GND
V C C _24V
V C C _24V
Video Input
24 pin DVI-I connector.
DDWG or equivalent connector.
P in
D escription
P in
D escription
P in
T.M.D .S . D ata2-
11
T.M.D .S . D ata1 S hi eld
21
D escription
NC
T.M.D .S . D ata2+
12
NC
22
T.M.D .S . C lock S hi eld
T.M.D .S . D ata2 S hi eld
13
NC
23
T.M.D .S . C lock+
NC
14
+5V P ower
24
T.M.D .S . C lock-
NC
15
Ground (for +5V )
25
A nalog Red
D D C C lock
16
Hot P lug D etect
26
A nalog Green
D D C D ata
17
T.M.D .S . D ata0-
27
A nalog B lue
A nalog V - S ync
18
T.M.D .S . D ata0+
28
A nalog H - S ync
29
GND (for analog si gnal)
D escription
T.M.D .S . D ata1-
19
T.M.D .S . D ata0 S hi eld
10
T.M.D .S . D ata1+
20
NC
15 pin VGA connector.
P in
D escription
P in
D escription
P in
GRE D
GND
11
NC
GGRE E N
GND
12
GS D A
IHS
GB LUE
GND
13
GND
G5V
14
IV S
GND
10
GND
15
GS C L
P in
D escription
P in
D escription
GND
C HROMA
GND
LUMA
S - Video connector.
C - Video connector.
P in
D escription
D ATA IN / OUT
AMM213TD 31
Description of Warranty
Advan warrants that the goods the goods sold hereunder will be free of defects in
materials and workmanship, and such goods will substantially conform to the specifications furnished by Advan, and to any drawings or specifications furnished to Advan
by the Buyer if approved by Advan. This warranty shall be effective only if Advan
receives notice of such defect or nonconformance during the period of the warranty.
Advan sole and exclusive the Advan product(s) with refurbished units provide a credit
to buyer in the amount of the purchase price.
Commencement and Duration of Warranty
The warranty period begins on the date of shipment from Advan. The goods sold
hereunder are warranted for a period of 18 months from date of shipment unless
otherwise agreed to by Buyer and Advan. No extension of the warranty will be given
during the time the goods are in Advan possession.
Place of Repair or Replacement
In order to obtain service under this warranty, Buyer must notify Advan of the defect
before expiration on the warranty period, and request a “Return Material Authorization
Number.” If the configuration has been modified in any manner, the product must be
returned to its original configuration before any warranty service will be perfomed by
Advan. No goods are to be returned to Advan without prior authorization. Buyer will be
responsible for packaging and shipping the defective goods to the Advan Service
Facility with shipping charges prepaid.
Limitation of Warranty
Monitor:
For 18 months after the date of purchase, ADVAN or its Authorized Service Centers, will
repair or replace if defective in material or workmanship. This Limited Warranty does not
include cleaning, or damage caused by accident, neglect, misuse or improper installation
or operation, any damage caused from service, maintenance, modifications or tampering
by anyone other than an ADVAN Authorized Service Representative, or by the use of
supplies, consumable items and conditions beyond the control of ADVAN, such as
common carrier provided equipment and/or facilities, operation of ADVAN product in
excess of the specifications or with the Serial Number or Rating label removed.
32 User’s Guide
ADVAN DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR PARTICULAR PURPOSE, EXCEPT TO THE EXTENT THAT ANY
WARRANTIES IMPLIED BY LAW CANNOT BE VALIDLY WAIVED.
No oral or written information or advice given by ADVAN, its authorized service center,
distributors, dealers, agents or employees, shall create another warranty or modify
this warranty. This warranty states ADVAN’s entire liability and your exclusive
remedy against ADVAN for any failure of the ADVAN’s product to operate properly.
Neither ADVAN nor anyone else involved in the development, production, or delivery of
this product shall be liable for any indirect, incidental, special consequential, exemplary, or punitive damages, including lost profits, arising from the use of or inability to
consequential or incidental damages, the above limitation may not apply to you.
This Limited Warranty gives you special legal rights and you may also have other
right, which vary from State to State.
Installation
Advan makes no warranty with respect to any installation of Advan’s product(s)
by Advan, any authorized dealer, or any other person.
Technical Assistance
For technical assistance please call (510)490-1005 between 8:00 a.m. and 5:00 p.m.
PST, Monday through Friday or email to support@advancorp.com with a description
of your technical issues.
Service
If your Medical Monitor needs service, call Advan Customer Service at (510)490-1005
between 7:00 a.m and 4:00 p.m PST, Monday through Friday or fax to (510)490-1151.
You will need the unit’s serial number and a brief description of the problem and where
unit were purchased to receive a RMA number.
If a service is required please return the product for service using the original
shipping container with the RMA number included in package on the outside
of the box.
In order to protect ADVAN employees form potential health hazards, ADVAN
requires that the RMA product be disinfected before returning to ADVAN for
service. Any product not cleaned prior to shipment will be returned to the
customer.
Note: Returns will not be accepted without an assigned RMA number.
In-transit damage is not covered by warranty. We suggest you always insure your
shipment. Advan will only pay for the return shipment by surface transportation. It is
the responsibility of the sender to prepay transportation charges.
ADVAN INT’L CORP
47817 Fremont Blvd. Fremont, CA 94538
Tel : 510-490-1005
Fax : 510-490-1151
Web Page : http://www.advancorp.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Modify, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2007:06:06 16:06:04-07:00
Subject                         : Untitled-1
Author                          : alanyu
Modify Date                     : 2007:08:07 15:04:10+09:00
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Keywords                        : 
Creator Tool                    : Adobe PageMaker 7.0
Format                          : application/pdf
Creator                         : alanyu
Description                     : Untitled-1
Title                           : Untitled-1
Document ID                     : uuid:4b9a971e-e76d-46b1-8179-336eb4b7c30b
Instance ID                     : uuid:2fa0b049-f98f-46b2-a161-fb4df43de5ff
Page Count                      : 36
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QVXAMM213TD

Navigation menu