BARCO AMM213TDS3 LCD Monitor User Manual EMISSION TEST REPORT

Advan Int'l Corp. LCD Monitor EMISSION TEST REPORT

users manual

   Test Report No.: GETEC-E3-06-043 FCC Class B Certification  EUT Type: 21” FLAT PANEL MONITOR   APPENDIX G : USER’S MANUAL    FCC ID: QVXAMM213TDS3
2006/05 www.stryker.com 1000-400-895 AVISIONELECT  21'' High-Definition LCD MonitorREF 240-030-930User Guide
16.42(417.20 mm)19.21(488 mm)5.05(128.20 mm)3.94(100 mm).95(24.25 mm)3.15(80 mm)2.05(52 mm)8.66(220 mm)6.23(163.20 mm)3.94(100 mm)4.99(127 mm)
1EnglishENTable of ContentsWarnings and Cautions ......................................................................... 2Warnings ........................................................................................... 2Cautions ............................................................................................3Symbol Definitions  ............................................................................ 5Product Description and Intended Use  ............................................... 6Product Contents  .............................................................................. 6Setting Up the Monitor .......................................................................... 8System Interconnection  .................................................................... 8Power Connection ............................................................................. 8Operating the Monitor ........................................................................... 9Front Panel Controls  ......................................................................... 9Standard On-Screen Display (OSD) Operation ............................... 10Stryker Camera Preset Modes ........................................................ 10OSD Function Description  .............................................................. 11Cleaning the Monitor ....................................................................... 12Troubleshooting  .................................................................................. 13Technical Specifications ..................................................................... 14Classification and Approvals ........................................................... 17Electromagnetic Compatibility ........................................................... 16Warranty ............................................................................................... 22Service and Claims .............................................................................. 22Declaration of Conformity  .................................................................. 23
2 Warnings and CautionsPlease read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed:WarningsWarning To avoid potential serious injury to the user and the patient, and/or damage to this device, the user must: 1. Restrict this device to use by, or on the order of, a physician, because of Federal law (United States of America).2. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment.3. Carefully unpack the unit and check if any damage occurred during shipment.4. Test this equipment prior to a surgical procedure. This monitor was fully tested at the factory before shipment.5. Do not place the monitor or any other heavy object on the power cord. Damage to the cable can cause fire or electric shock.6. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further.7. Unplug the unit if it is not to be used for an extended period of time. To disconnect the cord, pull it out by the plug. Never pull the cord itself.Warning The personal safety of the patient or physician may be involved. Disregarding this information could result in injury to the patient or physician.Warning A lightning bolt within a triangle is intended to warn of the presence of hazardous voltage. Refer all service to authorized personnel.Caution Special service procedures or precautions must be followed to avoid damaging the instrument.Note Special information to make maintenance easier or important information more clear.
3EnglishEN8. To avoid electric shock, avoid removing control unit covers.9. Do not attempt internal repairs or adjustments not specifically detailed in this operating manual.10. Pay close attention to the care and cleaning instructions in this manual. A deviation may cause damage (refer to the Cleaning section).11. Do not sterilize the monitor.12. Use appropriate caution to prevent contact with fluids, if the unit is being used with a power supply in patient environments.Cautions1. The AC Adapter must be plugged into a grounded power outlet.2. Use only the proprietary VISIONELECT (model 240-030-930) power supply (model 240-030-931) for the VISIONELECT (model 240-030-930) monitor. Make a proper connection by ensuring that the shrink tubing completely secures the connection between the DC power cord and the extension cord.3. Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle labeled “Hospital Only” or “Hospital Grade.”4. To connect to an international power supply, use an attachment plug appropriate for the power outlet.5. Turn power off when unit is not in use.6. Remove the power module and connection when transporting the unit.7. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit.8. Handle the monitor with care. Do not strike or scratch the screen.9. Never operate the unit right after having been transported from a cold location directly to a warm location.10. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently.11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation slots. The monitor is cooled by natural convection and has no fan. 13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
4 14. The unit is designed for operation in a horizontal position. Do not operate the unit in a vertical position.15. Keep the unit away from equipment that uses strong magnets (i.e., large loudspeakers).16. Do not touch the patient with signal input or output connectors. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standards or the combination should be evaluated. 17. CAUTION: Changes or modifications not expressly approved bythe party responsible for compliance could void the user's authorityto operate the equipment.NOTE : This equipment has been tested and found to comply with the limit for a  Cass B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide resonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation, which canbe determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more ofthe following measures.• Reorient or relocate the receiving device.• Increase the separation distance between the equipment.• Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected.• Consult the manufacturer or field service technician for help.18. To ensure electromagnetic compatibility, refer to the “Electromagnetic Compatibility” section of this manual. The VISIONELECT (model 240-030-930) monitor must be installed and operated according to the EMC information provided in this manual.The VISIONELECT (model 240-030-930) monitor has been tested under the UL 60601-1 standard and is UL listed for medical application. The warranty is void if any of these warnings or cautions are disregarded.
5EnglishENSymbol DefinitionsThe following symbols appear on the product, its labeling, or the product packaging. Each symbol carries a special definition, as defined belowDangerous: High VoltageConsult accompanying documents.Direct CurrentIndicates protective earth ground.For indoor use only.DC power control switchSerial NumberTop - BottomFragileDo not get wetMaximum StackingManufacturerEuropean Authorized RepresentativeIndicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities.Tested and certified by DEMKO in accordance with EN 60601-1 and  EN 60601-1-2.51LJMedical EquipmentE215822Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1 in regards to electric shock, fire hazards, and mechanical hazards.Tested to comply with FCC Class B standards.This symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment.SN
6 Product Description and Intended UseThe VISIONELECT (model 240-030-930) 21-Inch High Definition LCD Monitor is an intelligent, microprocessor-based TFT-LCD monitor intended for use in endoscopic surgical applications. It has an ergonomically designed display and is compatible with most analog RGB (Red, Green, Blue) display standards.The VISIONELECT (model 240-030-930) monitor has the following features:• Advanced Viewing Solution (AVS): A sophisticated filter extends the viewing angle of the screen image, without sacrificing contrast ratio and brightness.• Upgraded video cards or software will not require buying a new monitor because of the wide auto-scanning compatibility range.• The internal microprocessor digitally controls auto-scanning, for horizontal scan frequencies between 31.47 KHz and 78.88 KHz, and vertical scan frequencies between 50.0 Hz and 85.1 Hz. In each frequency mode, the microprocessor-based circuitry allows the monitor to function at the precision of a fixed frequency.• The resident memory allows for storing factory default settings and also additional user adjustment parameters.• The maximum resolution achievable is UXGA (1600 × 1200,be60Hz), st suited for Stryker cameras.• The monitor is compliant with the VESA-DPMS power- management standard. In order to save energy, the monitor must be connected to a system compliant with the standard.• The monitor is designed to mount an accessory (such as a camera or speaker) with a 2 lbs (max) load per hole.• The monitor is certified by UL International in accordance with medical standard UL 60601-1. It is also CE marked for sale in the European Community for integration or use with medical products. It is certified by DEMKO according to EN 60601-1 and EN 60601-1-2 for sale to the medical market.Product Contents1. Carefully unpack the VISIONELECT (model 240-030-930) monitor. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit.
7EnglishEN2. Check the monitor and its accessories for any damage that may have occurred during shipping. Immediately report any damage to the shipping company.3. Check the contents of the accessories package with the following list to make sure all components have been included. In addition to this manual, you should find:(a)  1 DVI cable(b)  1 VGA HDDB15 cable(c)  1 AC adapter (Stryker P/N 240-030-931)(d)  1 Hospital-grade AC power cord(e)  4 M4 x 10mm VESA screws (not shown)(f)   1 BNC cable(g)  1 S-Video cable(h)  1 15’ or 75’ extension cable with heat shrink tubing, for connection to the DC power cord (optional, not shown)(i)   Power supply bracket (optional, not shown)(a)(b)(c)(d)(f)(g)
8 System InterconnectionPower ConnectionVideo Input Signalseg:SDCSIDNEVIDEO PRINTERDVD/VCRetc...Video Sources:Camera (1188 Series,1088 Series, 988 Series)Video PeripheralSignal Output      DVI   RGBHV   S-Video   C-Video(Model 240-030-930)VISIONELECTVISIONELECT:Hospital-gradepower cord Power Supply240-030-931 Ground toCart ChassisHeat-shrink tubing between theDC power cord and extension cord 240-030-722 or240-030-932VISIONELECT(model 240-030-930)
9EnglishENOperating the MonitorFront Panel ControlsOperate the monitor using the rotary control located on the front panel. A list of the monitor controls and their functions is provided below.. Figure 1: The VISIONELECT LCD Monitor front panel controls. 1. Power LED: Indicates menu current status. Displays green if monitor is powered on, blinks orange if monitor is in Standby mode.2. Power Switch: Turns the power ON or OFF.3. Rotary Control (Turn Right): With the on-screen display menu activated, increases the value of the selected parameter. With the on-screen display deactivated, activates the video source selection menu.4. Rotary Control (Turn Left): With the on-screen display menu activated, decreases the value of the selected parameter. With the on-screen display deactivated, activates the video source selection menu.5. Rotary Control Switch (Push): Accesses/selects on-screen display menu.6. Rotary Control Switch (Push and Hold): Exits on-screen display menu.RotaryControlPower LEDPower Switch
10 Standard On-Screen Display (OSD) OperationThe monitor provides an on-screen display to help navigate through the various monitor-adjustment menus.1. Press the Rotary Control to activate the on-screen display (OSD) menu.2. Rotate the Rotary Control to move up or down through the menu. The parameter will be highlighted when selected.3. Press the Rotary Control to enter the next level OSD.4. Rotate the Rotary Control to increase or decrease the value of the selected parameter, or to make a selection on different options.5. To exit the OSD menu screen from the second- or third-level OSD menu, select the Exit option. To completely exit the OSD, press and hold the rotary control. If no keys are pressed for a time period, the OSD automatically times out.6. While the OSD menu is deactivated, rotate the Rotary Control to activate the input signal selection menu. The current input signal will be highlighted with a dot. Rotate the rotary control to select the preferred input signal.Stryker Camera Preset ModesCamera Resolution (H x V) Horizontal Frequency (KHz)Vertical Frequency (Hz)988 1024 x 768 49.09 59.90988i 1024 x 768 41.25 50.001088/SDC Pro2 1024 x 768 50.03 60.001088i/SDC Pro2 1024 x 768 41.10 50.001088/1188/SDC HD 1280 x 1024 64.02 60.101088i/1188i/SDC HD 1280 x 1024 59.99 50.00
11EnglishENOSD Function DescriptionActual on-screen display values may vary with updated versions of the firmware and user setting.* Only available under S or C video input.** Only available under VGA input.Item Function Description RangeSpecialtyColor Temperature  RGB adjustment is available only for Standard, Arth and Lap settings)Choose between color temperatures for Default, Standard, Arth, or LapRed Red balance 0-255Green Green balance 0-255Blue Blue balance 0-255Gamma Gamma value 1.6-2.4SettingBrightness Increase or decrease the brightness 0-100Contrast Increase or decrease the contrast  0-100Phase* Increase or decrease the Phase level 0-100Chroma* Increase or decrease the Chroma level 0-100Image Sharpness Set image sharpness from 1 to 10 1-10Video Sharpness* Increase or decrease the video sharpness 0-100Image EffectScale Mode Choose scale mode between fill screen, V-fill, H-fill, or one to oneMirror Enable or Disable mirror imageFreeze Frame Enable or Disable freeze frameZoom/Pan Enable zoom-in and pan functionPIP Enable PIP (Picture in Picture) functionAdvancedOSD position Control Control OSD Menu Position, Background, and TimeoutScreen Control** Control and adjust Horizontal, Vertical, Frequency, PhaseDPMS Choose DPMS (Display Power Management Signaling)Auto Source Select Adjust Auto Source Select between on and off.Recall Factory Default Set to factory defaultKey lock Set to Key lock modeInformationUser Name Entry Enter custom username display for boot-up displaySerial Number Display monitor serial numberRuntime Display current run time of monitorInput Format Display current input format
12 Cleaning the MonitorCaution Do not expose the monitor to moisture or directly apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently.No specific liquid or chemical is necessary for cleaning this  VISIONELECT (model 240-030-930) LCD monitor. Use only non-abrasive cloths and cleaning solutions to clean similar equipment used in hospitals.1. Clean the panel with a dry soft cloth, or a soft cloth lightly moistened with mild detergent solution. Do not use any type of solvent, such as alcohol or benzine, which might damage the finish.2. Apply alcohol to glass surfaces with soft cotton applicator to aid in cleaning and drying without leaving spots or streaks.3. Dry thoroughly with soft towel or gauze surgical sponge.Acceptable cleaning agents for bezel cleaning include:• Cidex (2.4% glutaraldehyde solution)• Sodium Hypochlorite (bleach) 10%• 0.5% Chlorhexidine in 70% isopropyl alcohol 70% isopropyl alcohol is recommended for the screen surface.
13EnglishENTroubleshootingBefore returning your LCD monitor for service, consult the troubleshooting list belowProblem Current Status RemedyNo PictureLED ON Using the OSD, adjust the brightness and contrast to maximum, or reset them to their default settings.LED OFFCheck the power switch.Check if the AC power cord is properly connected to the AC adapter.LED BlinkingCheck if the video signal cable is properly connected at the back of the monitor.Check if the power to the computer system is ON.Abnormal Picture Oversized or undersized display; missing display;  center shiftUsing the Auto Setup button, adjust CLOCK, CLOCK-PHASE, H-POSITION, and V-POSITION with non-standard signals.Wait for a few seconds after adjusting the size of the image before changing or disconnecting the signal or powering OFF the monitor.
14 Technical Specifications DisplayLCD Monitor Panel 21 inches (533.4mm)  (s/w TFT Active matrix LCD)Synchronization 2.5 - 5.0 Vpp separated syncPixel Pitch 0.270mmResponse Time <25msView Angle +/-85° (L/R) × +/-85° (U/D)Display Colors 16 million colorsNative Resolution 1600 dots × 1200 dotsInput Signal Composite video; S-video;  Analog RGB; DVIMaximum Pixel Clock 135 MHz × 1Electrical Power Adapter AC 100-240V; DC 24VPower Consumption 90W (max)Current DirectDimensionsDimensions (W × H × D) 499.66 x 428.88 x 104.25mmWeight 17 lbs.VESA Mounting Interface VESA 100mm × 100mmOperating ConditionsOperating Temperature 41 to 90°F (5 to 32.2°C)Relative Humidity 10 to 60%Electrical Input Rating 24V DC 3.75ATransport & Storage ConditionsStorage (-4 to 140°F) -20 to 60°C Relative Humidity Range 10 to 85%Atmospheric Pressure Range 500 to 1060 hPa
15EnglishENClassification and ApprovalsClass I EquipmentMedical equipment with respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1 and CAN/CSA C22.2  No. 601.1.IPX1 Water Ingress ProtectionContinuous operationWarning This equipment is not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR, or WITH OXYGEN OR NITROUS OXIDE.This monitor is intended for use on Health Care Facilities model  240-030-930.No user serviceable parts inside. Ask qualified personnel before accessing internal components.Caution For disposal of waste product, follow the requirement of the local code.This product is considered electronic equipment. It must not be disposed of as unsorted municipal waste, and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment. 51 LJMedical EquipmentE215822
16 Electromagnetic CompatibilityLike other electrical medical equipment, the VISIONELECT (model 240-030-930) monitor requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the VISIONELECT (model  240-030-930) monitor must be installed and operated according to the EMC information provided in this manual. Note The VISIONELECT (model 240-030-930) monitor has been designed and tested to comply with IEC 60601-1-2:2003 requirements for EMC with other devices.Caution The VISIONELECT (model 240-030-930) monitor may be interfered with by other equipment, including portable and mobile RF communication equipment, even if such equipment meets the applicable emissions requirements.Warning Do not use cables or accessories other than those provided with the VISIONELECT (model 240-030-930) monitor, as this may result in increased electromagnetic emissions or decreased immunity to such emissions.Warning If the VISIONELECT (model 240-030-930) monitor is used adjacent to or stacked with other equipment, observe and verify normal operation of the VISIONELECT (model 240-030-930) monitor in the configuration in which it will be used prior to using it in a surgical procedure. Consult the tables below for guidance in placing the VISIONELECT (model 240-030-930) monitorWarning When this device is connected with other electrical equipment, leakage currents may be additive. To minimize total leakage current per patient, ensure that all systems are installed according to the requirements of IEC 60601-1.
17EnglishENGuidance and Manufacturer's Declaration: Electromagnetic Emissions VISIONELECT (model 240-030-930) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISIONELECT (model 240-030-930) monitor should ensure that it is used in such an environment.Emissions test Compliance  Electromagnetic Environment - guidanceRF emissionsCISPR11 Group 1The VISIONELECT (model 240-030-930) monitor must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be affected.RF emissionsCISPR11 Class BVISIONELECT (model 240-030-930) monitor is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes.Harmonic emissionsIEC61000-3-2 Class AVoltage Fluctuations/flicker emissionsIEC61000-3-3 Complies
18 Guidance and Manufacturer's Declaration: Electromagnetic ImmunityVISIONELECT (model 240-030-930)  monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISIONELECT (model 240-030-930) monitor should ensure that it is used in such an environment.Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment: GuidanceElectrostatic Discharge (ESD)IEC61000-4-2±6kV contact±8kV air ±2,4,6kV contact±2,4,8kV airFloors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.Electrical fast transient/burst IEC61000-4-4±2kV for power supply lines ±1kV for input/output lines±2kV line to ground±1kV line to lineMains power quality should be that of a typical commercial or hospital environment.SurgeIEC61000-4-5±1kV differential mode±2kV common mode±0.5, 1kV differential mode ±0.5, 1, 2kV common modeMains power quality should be that of a typical commercial or hospital environment.Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-11<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.<5% Ut (>95% dip in Ut) for 0.5 cycle40% Ut (60% dip in Ut) for 5 cycles70% Ut (30% dip in Ut) for 25 cycles<5% Ut (>95% dip in Ut) for 5 sec.Mains power quality should be that of a typical commercial or hospital environment. If the user of VISIONELECT (model 240-030-930) monitor requires continued operation during power mains interruptions, it is recommended that VISIONELECT (model 240-030-930) monitor be powered from an uninterruptible power supply or a battery.Power frequency (50/60Hz) magnetic fieldIEC 61000-4-8 3 A/m N/APower-frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
19EnglishENNOTE: Ut is the AC mains voltage prior to application of the test level.Guidance and Manufacturer's Declaration: Electromagnetic ImmunityVISIONELECT (model 240-030-930) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISIONELECT (model 240-030-930) monitor should ensure that it is used in such an environment.Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment: GuidancePortable and mobile RF communications equipment should be used no closer to any part of the VISIONELECT (model 240-030-930) monitor system, including its cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.Conducted RFIEC 61000-4-6 3 Vrms150 kHz to 80 MHz 3 V Recommended Separation DistanceRadiated RFIEC 61000-4-3 3 V/m80MHz to 2.5 GHz 3 V/m 80 MHz to 800 MHz 800 MHz to 2.5 GHzwhere P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range(b).Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.Guidance and Manufacturer's Declaration: Electromagnetic ImmunityVISIONELECT (model 240-030-930)  monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISIONELECT (model 240-030-930) monitor should ensure that it is used in such an environment.d1.17P=d1.17P=d2.33P=
20 NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast, cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which theVISIONELECT (model 240-030-930) monitor system is used exceeds the applicable RF compliance level above, the VISIONELECT (model 240-030-930) monitor system should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the VISIONELECT monitor VISIONELECT (model 240-030-930) monitor unit.(b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.Guidance and Manufacturer's Declaration: Electromagnetic ImmunityVISIONELECT (model 240-030-930) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISIONELECT (model 240-030-930) monitor should ensure that it is used in such an environment.
21EnglishENRecommended Separation Distances Between Portable and Mobile RF CommunicationsEquipment and the VISIONELECT (model 240-030-930) monitor SystemThe VISIONELECT (model 240-030-930) monitor system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the VISIONELECT (model 240-030-930) monitor system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the VISIONELECT (model 240-030-930) monitor system as recommended below, according to the maximum output power of the communications equipment.Rated maximum output power (W) of transmitterSeparation distance (m) according to frequency of transmitter150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz0.01 0.12 0.12 0.230.1 0.37 0.37 0.7411.171.172.3310 3.70 3.70 7.37100 11.70 11.70 23.30For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.d1.17P=d1.17P=d2.33P=
22 WarrantyThis Stryker Endoscopy product is warranted to the original purchaser for a period of one year from the date of purchase to be free from defects in material and workmanship.This warranty extends to all purchases and is limited to the repair or replacement of the product without charge when returned in the original shipping case to:Stryker Endoscopy5900 Optical CourtSan Jose, CA 95138USAStryker Endoscopy cannot accept responsibility for returns or replacements which have not been authorized. This warranty does not cover damages caused by misuse or by failure to follow the procedures outlined in this manual or demonstrated by Stryker Endoscopy representatives.There are no other expressed warranties.Service and ClaimsDo not attempt to service this product yourself. If service is needed either during or after the warranty period, contact Stryker Endoscopy at  1-800-624-4422, or phone your local Stryker Endoscopy sales representative.
23Declaration of ConformityManufacturer: Stryker Endoscopy 5900 Optical Court San Jose, CA 95138 USA 1-800-624-4422 1-408-754-2000Product Designation: VISIONELECT (model 240-030-930) 21" High Definition LCD MonitorThe above product complies with the requirements of EC Directive 93/42/EEC. This declaration is based on compliance testing to:EN 60601-1/08-90 EN 60601-1 A1/05-93 EN 60601-1 A2/06-95This document is on file.The CE mark will be affixed based on directive 93/42/EEC.Stryker European RepresentativeRegulatory Manager, Stryker FranceZAC Satolas Green PusignanAv. de Satolas Green69881 MEYZIEU Cedex, FranceStryker and Stryker Endoscopy are registered trademarks of Stryker Corporation.
24
2006/05 www.stryker.com 1000-400-895 AStryker Endoscopy 5900 Optical Court San Jose, CA 95138 USA 1-408-754-2000, 1-800-624-4422 www.stryker.comEuropean Representative:Regulatory Manager, Stryker FranceZAC Satolas Green PusignanAv. De Satolas Green69881 MEYZIEU Cedex, France

Navigation menu