BARCO AMM240ED LCD Color Medical Monitor User Manual

BARCO, INC. LCD Color Medical Monitor

User manual

AUTO - SCANNING WITH DIGITAL CONTROLLCD COLOR MEDICAL MONITORAMM240EDOperation ManualFor future reference, record the serial number of your display monitor in the space below :Serial NumberThe serial number is located on the back of the monitor
Back of the MonitorBarco, Inc. 2017             All other trademarks are the property of their reference owners.This document is subject to change without notice.BARCO provides this information as reference only. Reference to other vendor’s products does not imply any recommendation or endorsement.Revision ControlWARNINGThe title «WARNING» is used to inform the users of pos-sible causes that could inict the injury, death, or property damage to the patients. CAUTIONThe title «CAUTION» is used to inform the users of pos-sible causes that could inict the patients although it might not severe enough to cause death. NOTEThe title «NOTE» is used to inform the users of items that are of importance in terms of installation, operation, or maintenance of the Equipment although the failure does not inict the bodily harm to the patients. Document number I-101117190001Rev. AAMM240ED   1
Table of ContentsProduct Description and Intended Use ......................................................Warnings and Cautions .............................................................................Symbol Denitions .....................................................................................EU Declaration of Conformity for Medical Applications .............................Safety Precaution ......................................................................................Cleaning the Monitor .................................................................................Recommendation to Use more than One Unit...........................................On Burn-in .................................................................................................Power Management Function....................................................................Preset Modes..............................................................................................Video Signals .............................................................................................PIP / POP / PBP function...........................................................................DDC ...........................................................................................................Installation .................................................................................................Connecting the Power Cord ......................................................................User Function / Messages.........................................................................OSD Section ..............................................................................................Troubleshooting .........................................................................................Specications of (AMM240ED)..................................................................Classication .............................................................................................Electromagnetic Compatibility ...................................................................Dimension Drawing (mm) of AC Adapter ...................................................Dimension Drawing (mm) of AMM240ED ..................................................Connectors ................................................................................................Description of Warranty .............................................................................  3  4  7  8  9  99910111213141415161725262728303132342    User’s Guide
Product Description and Intended UsePlease check the following items are present when you unpack the box, and save the packing materials in case you will need to ship or transport the monitor in future.•  AMM240ED LCD Monitor (the equipment that displays information, graphic data, image and video on the LED screen) and two video cables    (1) BNC x4 to HD15 Cable(1) DVI-I cable •  AC Power cord*•  AC-Adapter•  BNC Cable, and Y/C Cable.•  CD Multi-language Manual, English User Manual and 4pcs VESA screws•  Stand (optional)•  DC extension cable (optional)•  Cable Cover *Might vary pending on region standardCAUTIONModel No :BM060S24F06                  (Bridgepower) AMM240ED   315ft length: Model 1501047***(Bridgepower)75ft length: Model 1501047***(Bridgepower)***: blank or 001~99933-329-085, SB-004W
Warnings and CautionsPlease read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed: Warning  The personal safety of the patient or physician may be                  involved. Disregarding this information could result in                  injury to the patient or physician.Caution  Special service procedures or precautions must be                   followed to avoid damaging the instrument.Note  Special information to make maintenance easier or important information more clear.                  An exclamation mark within a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the product.                  A lightning bolt within a triangle is intended to warn of the                   presence of hazardous voltage. Refer all service to authorized personnel.Warning  TO AVOID POTENTIAL SERIOUS INJURY TO THE USER AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE, THE USER MUST :Warranty is void if any of these warnings are disregarded. Barco, Inc. accepts full responsibility for the effects on safety, reliability, and performance of the equipment only if:• Re-adjustments, modications, and/or repairs are carried out exclusively    by Barco, Inc.• The electrical installation of the relevant operating room complies with the    applicable IEC and CE requirements.Warning      Federal law (United States of America) restricts this                     device to use by, or on order of a physician.The Barco, Inc. AMM240ED monitor has been tested under UL (ANSI/AAMI ES 60601-1) standard and UL listed for Medical application. Barco, Inc. reserves the right to make improvements in the product(s) described herein. Product(s), therefore, may not agree in detail to the published design or specications. All specications are subject to change without notice. Please contact Barco, Inc. directly or phone your local Barco, Inc. sales representative or agent for information on changes and new products.4    User’s Guide
Warnings1.  Read the operating manual thoroughly and be familiar with its contents prior to using      this equipment.2.  Carefully unpack the unit and check if any damage occurred during shipment.3.  Should any solid object or liquid fall into the panel, unplug the unit and have it checked      by qualied personnel before operating it any further.4.  Uplug the unit if it is not to be used for an extended period of time. To disconnect the      cord, pull it out by the plug. Never pull the cord itself.5.  Be a qualied physician, having complete knowledge of the use of this equipment.6.  Test this equipment prior to a medical procedure. This monitor was fully tested at the      factory before shipment.7.  Avoid removing covers on control unit to avoid electric shock.8.  Attempt no internal repairs or adjustments not specically detailed in this operating      manual.9.  Pay close attention to the care, cleaning instructions in this manual. A deviation may      cause damage (refer to the Cleaning section).10. DO NOT STERILIZE MONITOR.11. Read the entire instruction manual before assembling or connecting the camera.12. Do not place the monitor or any other heavy object on the power cord. Damage to the       cable can cause re or electirc shock.13. Monitor with power supply is suitable for use in patient environment.14. DO NOT stack more than 3 boxes high15. To avoid the risk of electric shock, this equipment must only be connected to a supply       mains with protective earth.This equipment has been tested and found to comply with the limits for medical devices in IEC 60601-1-2:2014. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devic-es in the vicinity. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to other devices, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  - Reorient or relocate the receiving device.  - Increase the separation between the equipment.  - Connect the equipment into an outlet on a circuit different from that to which the other   device(s) are connected.  - Consult the manufacturer or eld service technician for help.NOTICES TO USERThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any inter-ference received, including interference that may cause undesired operation.FCC WARNINGThis equipement generates or uses radio frequency energy.  Changes or modications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The user could lose the authority to operate this equipment if an unauthorized change or modication is made. AMM240ED   5
Cautions1.  The AC Adapter must be plugged into a Grounded power outlet.2.  Use only the proprietary  AMM240ED power supply for the      AMM240ED monitor. Make a proper connection by ensuring that the      shrink tubing completely secures the connection between the DC power cord and the      extension cord.3.  Turn power off when unit is not in use.4.  Never operate the unit right after having transported from a cold location directly to a      warm location.5.  Do not expose the monitor to moisture or directly apply liquid cleaners directly to the      screen. Spray the cleaning solution into a soft cloth and clean gently.6.  Handle the monitor with care. Do not strike or scratch the screen.7.  Do not block the monitor cooling vents. The monitor is cooled by natural convection      and has no fan. 8.  Do not force the monitor past 28 degrees of vertical when adjusting the screen      position. (For monitors equipped with stands only.)9.  Remove the power module and connection when transporting the unit.10. Save the original carton and associated packing material. They will be useful should        you have to transport or ship the unit.11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,       draperies) that may block the ventilation slots.13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.14. The unit is designed for operation in a horizontal position. Never operate the unit in        a vertical position.15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)16. Do not expose the monitor to moisture or excessive dust.17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1       harmonized national standard or the combination should be evaluated.       Do not touch the patient with signal input or output connectors.18. Use only a hospital grade power supply cord.19. This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable generate uses and can radiate radio frequency energy, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation, which can be detemined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving device.  •  Increase the separation distance between the equipment.  •  Connect the equipment to an outlet on a circuit different from that to which the       other device(s) are connected.  •  Consult the manufacturer or eld service technican for help.20. Grounding reliability can only be achieved when the equipment is connected to an       equipment receptacle labeled “Hospital Only” or “Hospital Grade.”21. The products have lower breaking capacity type. So do not install at the building power       system prospective short-circuit current exceeding 35 A.22. Disconnecting of the power cord from teh AC/DC Adapter is the proper means of isolation       from the supply mains.6    User’s GuideNote  To connect to an international power supply, use a an attachment plug                appropriate for the power outlet.Note  Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to                ensure EMC. The AMM240ED must be installed and operated                according to the EMC information provided in this manual.
AMM240ED   7Dangerous: High VoltageDirect CurrentSerial NumberThis Way UpFragile, Handle with CareStacking Limit by NumberKeep DryRecyclableSee Accompanying DocumentIndicates proof of confor-mity to applicable European Economic Community Council directives and to harmonized standards published in the of-Communities.Authorized Representative in EuropeDate of ManufactureManufacturerMedical EquipmentIndicates Protective Earth Ground.For Indoor Use Only.Tested to Comply with FCC Class B Standards.Stand-byTested to Comply with Japan Tested to Comply with China BSMI Mark for Taiwan          ApprovalMark for CU Countries-Russia,Kazakhstan, BelarusChina RoHS symbol. Number indicates EFUP(Environmental Friendly Use Period) from the date of manufacturing.Medical Equipment is in ac-cordance with ANSI/AAMI ES 60601-1 and CAN/CSA C22.2 No. 60601-1 in regards to electric shock, hazards.Tested to Comply with IP (Ingression Protection) RatingWEEE symbol for recyclable product. Please do not throw the product with this symbol in the bin.
EU Declaration of Conformity for Medical ApplicationsA Declaration of Conformity has been led for this product. A sample of this document may be found in the addendum which accompanies this manual.  For a copy of the Declaration of Conformity document, please contact Barco, Inc. and request the AMM240ED DOC.Prepare to Unpack MonitorBefore you unpack your monitor, prepare a suitable workspace. You need a stable and level surface near a grounded wall outlet in an area which is relatively free of glare from sunlight or other sources of bright light. The monitor is cooled by natural convection (it has no fan). For optimum performance, do not block the cooling vents.While unpacking the monitor, inspect it and other package contents for shipping damage that could cause a re or shock hazard. Imme-diately report any shipping damage to the carrier or transportation company and contact customer service for monitor in case of return.After you unpack the monitor, make sure the following items are in-cluded  •  Monitor with video cable  •  AC adapter with cable           CAUTION: AC Adapter must be plugged into Grounded a power outlet          CAUTION : AC adapter          Model No: BM060S24F06 (Bridgepower)       •  This operation manual          Note:  Your system provider may offer alternative cords or cables depending on the installation requirement and local geography issues.8    User’s Guide
Safety Precaution·  Avoid placing the monitor, or any other heavy object, on the power cord ·  Do not expose the monitor to rain, excessive moisture, or dust to avoid ·  Do not cover the slots or openings of the monitor for proper heat        dissipation. Always put the monitor in a place where there is adequate       ventilation.·  Avoid placing the monitor against a bright background or where sunlight . Place the       monitor just below eye level.·  Handle with care when transporting the monitor.·  Refrain from giving the shock or scratch to the screen, as screen is        fragile.·  Performance of preventive maintenance is not essential. Periodic maintenance inspections are essential to keep the monitor in optimum condition and ensure safe operation. We recommend a functional and safety test of the monitor at regular intervals (e.g. at least once a year).Cleaning the MonitorHowever, we suggest to clean the monitor with non-abrasive cloths and cleaning solutions used in hospitals to clean similar equipment. We recommend using 70% isopropyl alcohol for the screen surface and warm water and a mild detergent for all other surfaces. Other acceptable cleaning agents are listed below:  •  70% isopropyl alcohol  •  Cidex (2.4% glutaraldehyde solution)  •  0.5% Chlorhexidine in 70% isopropyl alcoholTo clean the screen, do not spray liquid cleaners directly on to the unit. Stand away from the monitor and spray cleaning solution onto a cloth. Without applying exces-sive pressure, clean the screen with the slightly dampened rag.Recommendation to Use More Than One UnitAs unforeseen situations can occasionally occur for the monitor, when the display is used please use a safety control. It is strongly recommended you use more than one unit or prepare a spare unit in case there is an emergency.AMM240ED   9On Burn-inPermanent burn-in may occur from the following:   •  Displaying color bar or static images repeatedly or for a long period of time.   •  Using the unit repeatedly in a high temperature/ high humidity environment  •  Displaying an image smaller than the monitor continuously.To reduce the risk of burn- in, it is recommended to turn off the power of the unit, and reduce the brightness when the unit is not in use.
Power Management FunctionThe monitor is equipped with the power management function which automatically reduces the power consumption when not in use in three power level modes.• Stand-by ModeThe monitor goes into stand-by mode when the horizontal sync signal is off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 second On and 1 second Off. The screen is displayed after the horizontal sync signal is restored.•Suspend ModeThe monitor goes into suspend mode when the vertical sync signal is off for about 10 seconds. The power consumption during this is 10 W. In this mode, the screen goes off and the power LED blinks for 1 second On and 1 second Off. The screen is displayed after the vertical sync signal is restored.• Off ModeThe monitor goes into power-off mode when the vertical and horizontal sync signals are off for about 10 seconds. In this mode, the screen goes off and the power LED blinks for 1 second On and 1 second Off. The screen is displayed after the vertical and horizontal sync signals are restored.Power Management SystemThe AMM240ED Medical Monitor power management proposal provides four phases of power saving modes by detecting the horizontal sync signal as shown in the table below.When the monitor is power saving mode or detects an incorrect timing, the screen will be blank and power LED indicator will blink.10    User’s GuideState Normal OperationDPMS StandbyDPMS Suspend DPMS OffHorizontal Sync Active Inactive Active InactiveVertical Sync Active Active Inactive InactiveVideo Active Blanked Blanked BlankedPower Indicator Green Green Flashing (1 sec. Interval)Green Flashing (1 sec. Interval)Green Flashing (1 sec. Interval)Power Consumption 40W 15W 15W 15W
PRESET MODESAMM240ED   11ResolutionHorizontal frequency     ( KHz )Vertical frequency     ( Hz )Pixel  clock    ( MHz )640 x 350 @70Hz 31.469 70.087 25.175640 x 480 @60Hz 31.469 59.940 25.175640 x 480 @75Hz 37.500 75.000 31.500800 x 600 @56Hz 35.156 56.250 36.000800 x 600 @60Hz 37.879 60.317 40.000800 x 600 @75Hz 46.875 75.000 49.5001024 x 768 @60Hz 48.363 60.004 65.0001024 x 768 @70Hz 56.476 70.069 75.0001024 x 768 @75Hz 60.023 75.029 78.7501152 x 864 @60Hz 54.348 60.053 80.0001152 x 864 @70Hz 63.955 70.016 94.2001152 x 864 @75Hz 67.500 75.000 108.0001280 x 1024 @60Hz 63.981 60.02 108.0001680 x 1050 @60Hz 64.742 59.946 119.1251680 x 1050 @60Hz 65.160 59.944 147.0001600 x 1200 @60Hz 74.077 59.981 130.3751920 x 1080@60Hz  67.500 60.00 148.5001920 x 1200@60Hz 74.099 59.999 154.125Input Signal Timing
Video Signals12    User’s GuideFormat DVI-I HD-15 Y/C SDI1 SDI2Component/RGBs Y/Pb/Pr/RGB+SOGRGB+ CSNTSC-MNTSC-443 OPAL-BDGHIPAL-MPAL-NPAL-60O480/59.94i O O O O480/59.94p O O576/50i O O O O576/50p O O O O720/50p O O O O O O720/59.94p O O O O O O720/60p O O O O O O1080/23.98p O O O O O1080/24p O O O O  O1080/25p O O O O O O 1080/29.97p O O O O O O1080/30p O O O O O O1080/50i O O O O O1080/59.94i O O O O O1080/60i O O O O O1080/50p O O1080/60P O O
AMM240ED   13PIP / POP / PBP Function*The following combination options are available to you:                PIPMain DVI-I SDI1  SDI2(Optional)Component / RGBs HD-15 Y/CDVI-I X O X O O OSDI 1 O X O O O XSDI 2(Optional) X O X O O OComponent/RGBs O O O X X OHD-15 O O O X X OY/C O X X O O X*When the frame frequency of the main screen is different from that of the sub screen, the picture may   be disturbed.*When both main and sub screens input interlace signals, the picture may be disturbed.
DDCTo make your installation easier, the monitor is able to Plug and Play with your system if your system also supports DDC protocol. The DDC (Display Data Channel) is a communication protocol through which the monitor automatically informs the host system  about its capabilities, for example, supported resolutions and corresponding timing. The monitor supports DDC1 and DDC2B standard.InstallationTo install the monitor to your host system, please follow the steps as given below:Steps1. Use the supplied video cable (DVI-I, Y/C, BNC, BNCx4 to HD15) then connect to the   host system accordingly.2. Connect the DC power to the DC power connector on the monitor.3. Connect one end of AC power cord into the AC Adapter and the other end to AC   power outlet.4. Then turn the host system on and then the monitor.5. If the monitor still does not function properly, please refer to the troubleshooting   section to diagnose the problem.14    User’s GuideRS232CDC PowerHD/SD SDI1 INUSBHD/SD SDI1 OUTHD15/RGBS INDVI-I INHD/SD SDI2 INY/C INDVI-I OUT
Connecting the Power Cord*   the area.*   This  monitor  has  an  universal AC  adapter  that  allows  operation  in  either  AC 100 - 240 V ac voltage area.  No user-adjustment is required.*   Plug one end of the power cord to the AC adapter, plug another end to a proper AC outlet.The cord set should have the appropriate safety approvals for the country in which the equipment will be installed and marked HAR.For 120 volt Applications, use only the UL Listed detachable power cord with NEMA (tandem blades) plug cap.AMM240ED   15Hospital-grade power cordPower SupplyModel No: BM060S24F06  AMM240EDExtension power cord (optional)15ft length: Model 1501047***(Bridgepower)75ft length: Model 1501047***(Bridgepower)***: blank or 001~999
16    User’s GuideUser Functions / MessagesKey Name and FunctionPower : Turns ON/OFF the system.Menu : Enter /Exit OSD menu.Left : Decrease setting/Value.Right : Increase setting/value. Enter Sub menuUp : Move to previos item.Down : Move to next time.Select : Select item.Brightness : Quick key for brightness adjustment.Contrast : Quick key for contrast adjustment.Scale Mode : Quick key for scale mode adjustmentInput: Activate the video source selection menu.How to Access the Menu.1. Press the Menu button to activate the OSD menu.2. Press the Up or Down button to select icons. The icon will behighlighted when selected.3. Press the right arrow button to go into another OSD menu.4. Press the enter button to select sub menu and the right arrow or left arrow button to select the function.5. In order to exit from the OSD menu, choose the “Exit” icon. Press the menu but-ton, then it will completely exit from the menu regardless of where you are.6. Press the input button to enter the input menu. Push the Up or Down arrow to highlight the correct input and press enter to select the input.Power Switch
AMM240ED   17OSD SectionChromatic  Adjust Color Temp, GammaVisual    Adjust Brightness, Contrast, Phase, Chroma,     Sharpness-V, Sharpness-HSetting    Adjust Scale Mode, Color Space, Freeze Frame,     Zoom / Pan, PIP, POP, PBPAdvanced  Adjust OSD Position Control, Screen Control, DPMS, Auto     Source Select, Smart Select, Restore Factory, Key Lock,     OverscanInformation  User Customer Entry, Serial Number, Runtime, Input Format,   ExitMain Menu
18    User’s GuideOSD SectionChromaticColor Temp  Change the Color Temperature - D65, D93, SYS-1, SYS-2  Red  0~100  Green 0~100  Blue 0~100Gamma    Change the Gamma Value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,     2.4, 2.4S, S0, RadiographExit    Exit the MenuVisualBrightness  Adjust the Brightness of Panel (Range 0 - 100)Contrast   Adjust the Contrast of Video (Range 0 - 100)Phase    Adjust the Phase of Video (Range 0 - 100)  *Available for Y/C and HD/SD SDI1 onlyChroma    Adjust the Chroma of Video (Range 0 - 100)    *Available for Y/C and HD/SD SDI1 onlySharpness-V  Set the Sharpness of Vertical Image (Range 0 - 20)Sharpness-H  Set the Sharpness of Horizontal Image (Range 0 - 20) Exit    Exit the Menu
OSD SectionSettingScale Mode  Change the Scale Mode - Fill all, One to One,    Vertical - Fill, Horizontal - Fill, Fill aspect ratioColor Space  Change Color Space Between RGB and YUVFreeze Frame  Off / On Freeze FrameZoom / Pan  Activate zoom/pan OSDPIP    Activate PIP MenuPOP    Activate POP MenuPBP    Activate PBP MenuExit    Exit the MenuAMM240ED   19
20    User’s GuideOSD SectionMode    PIP Mode ON / OFFSource    PIP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2    Component/RGBs, HD15, Y/CPosition    PIP Sub Screen Position - Top L, Top R, Bottom L, Bottom RSize   PIP Sub Screen Size - Small, Medium, LargeBlending   PIP Sub Screen Blending (Range 0 - 20)Swap    PIP Sub Screen SwapExit    Exit the MenuMode    PBP Mode ON / OFFSource    PBP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2    Component/RGBs, HD15, Y/CSwap    PBP Sub Screen SwapExit    Exit the MenuSub menu of PBPSub menu of PIP
Mode    POP Mode ON / OFFSource    POP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2     Component/RGBs, HD15, Y/CPosition    POP Sub Screen Position - Top L, Top R, Bottom L, Bottom RSize   POP Sub Screen Size - Small, Medium, LargeBlending   POP Sub Screen Blending (Range 0 - 20)Swap    POP Sub Screen SwapExit    Exit the MenuSub menu of POPAMM240ED   21OSD Section
22    User’s GuideOSD Section AdvancedOSD Position  Change the OSD Menu - H and V Position, Background, Control    OSD Time Out, LanguageScreen Control  Control and Adjust H and V position, Freqency, Phase,    Noise Reduction, Motion OffsetDPMS    Change the DPMS - Off, 60 min, 90 min, 120 min, NormalAuto Source  Adjust Auto Source Select Between On and OffSelectSmart Select  Enable / Disable Smart Select Sub Menu - Model A, Model B    Model C, Model DRestore Factory  Changes All OSD Value to Factory Outgoing Status(associated with the Color Temperatures are factory calibrated with a consequent reduction of the maximum luminance comparedto Native Color Temperature.)Key Lock  Set to Key Lock ModeOverscan  Adjust Overscan Ratio - Off, Step 1, Step 2, Step 3, Step 4,     Step 5, Step 6, Step 7Exit    Exit the Menu
OSD SectionSub Menu of OSD ControlH-position  Adjust OSD H - Position (Range 0 - 100)V-position  Adjust OSD V - Position (Range 0 - 100)   Back ground  Adjust Transparency of OSD Background (Range 0 - 20)OSD Timeout  Adjust OSD timeout - 5s, 10s, 15s, 20s, 1m, 2mLanguage  OSD Language - English, Japanese, Chinese, Korean,   French, GermanExit    Exit the MenuH-Position  Adjust Screen H - Position (Range 0 - 100)  *Available for HD15, HD/SD SDI1 Component/RGBsV-Position  Adjust screen V - Position (Range 0 - 100)  *Available for HD15, HD/SD SDI1 Component/RGBsFrequency  Adjust Frequency (Range 0 - 100)  *Available for HD15Phase   Adjust Phase (Range 0 - 100)  *Available for HD15Noise    Noise Reduction (Range 0 - 31)Reduction Motion Offset  Motion Offset (Range 0 - 100)  Exit    Exit the MenuSub menu of Screen ControlAMM240ED   23
24    User’s GuideOSD Section InformationCustom Entry  Change the User or Monitor’s Name    Custom Entry Row 1, Custom Entry Row 2SN    Display the Serial NumberRuntime   Display the Total RuntimeInput Format  Display the Current input Resolution and Vertical FrequencyExit    Exit the Menu
TROUBLESHOOTINGBefore sending your LCD monitor for servicing, please check the troubleshooting list below to see if you can self-diagnose the problem.AMM240ED   25Problems Current Status RemedyNo Picture Power LED ON ·  Using OSD, adjust brightness and contrast to maximum or reset to their default settings.Power LED OFF ·  Check the Standby Power Button and Power switch.·  Check if AC power cord is properly connected to the AC adapter.Power LED Blinking ·  Check if video signal cable is properly connected at the back of monitor.·  Check if the power to computer system is ON.Abnormal Picture  Unstable  Picture ·  Check if the specication of graphics adapter and monitor is in compliance which may be causing the input signal frequency mismatch.Display is missing, center shift, or too small or too large in display size·  Using the Screen Control Menu, adjust the Phase, Frequency, Horizontal, and Vertical settings in order to correct the display image.
26    User’s GuideSpecication** All contents are subject to change without notice.**Brightness shown is without touch screen or A/R lter installed.Model AMM240EDDiagonal 24.07 inches (611.32) diagonalResolution 1920 (H) x 1200 (V) @ 60hzPixel Pitch 0.270mm x 0.270mmDisplay Color 16.7M colorsViewing Angle H: 178°, V: 178°Brightness 300 cd/m² (typical)Contrast ratio 1000:1 (typical)Dimension 570 (W) x 386.8 (H) x 63.2 (D) mmColor Gamut sRGB 100%LCD Response Time 14msec (Typ.)InputHD/SD SDI 1BNC x 1HD/SD SDI 2          (optional)BNC x 10.27~2.97Gb/s Serial input data  rate0.27~2.97Gb/s Serial input data rate500~1100mVp-p Serial input swing720~880mVp-p Serial input Voltage swingHD1515p D-Sub (female)DVI-IDVI-I 24+5 pin (female)Video: 0.7 ± 0.1 VP-p H/V Sync: TTL Level (V high ≥2.3V, V low ≤0.5V)TMDS LevelHorizontal Frequency 30~80KHz Vertical Frequency 50~85Hz MAX. 162MHzMAX. 162MHz OutputComponent/RGBs15p D-Sub (female) (BNCx4 to HD15 CableHD/SD SDIBNC x 1 ( 75 ohm ±5% )RGB: 0.7 ± 0.1 Vp-p 0.27~2.98Gb/s Serial output data rateComposite Sync : 0.3Vp-p ~ 5Vp-p H/V SYNC : TTL Level350~600mVp-p Serial output swingY/CMini Din 4-pinDVI-IDVI-I 24+5 pin (female)NTSC, PAL Color standard TMDS LevelLuminance : 1.0± 0.1VP (Video :0.7Vp-p / Sync : 0.3Vp-p) Chromi-nance : 0.3 ± 0.03Vp-pMAX. 162MHzGeneralPower Adaptor AC 100 ~ 240V 50-60HzDC 24V, 2.7APower Consumption 40WPackage Dimension 665 x 240 x 640 (H)Weight Monitor : 7.35Kg (Without cable cover, Without stand)AC adaptor : 410gVESA Mounting 75mm x 100mmOperating/Storage EnvironmentOperating Tempera-ture 50° ~ 104°F (10° - 40°C)Operating Humidity 25% ~ 75%, non-condensingStorage Temperature -0° ~ 140°F (-18° - 60°C)Storage Humidity 15 ~ 90%RH (without condensation)Compliance &CerticationSafety UL(ANSI/AAMI ES 60601-1), cUL(CAN/CSA-C22.2 No. 60601-1), CE(EN 60601-1, IEC 60601-1), AS/NZS 3200-1-0, CCC(GB4943.1), CB-ITE (IEC 60950-1), IP22 ComplianceEMC FCC(Part 15 Class B), CE(EN 60601-1-2, IEC 60601-1-2), AS/NZS 3200-1-2, VCCI(Class B), CCC(GB9254, GB17625.1)Optional ModuleDC Extension Cable 5ft, 15ft, 75ft lengthBase Stand Adjustable high, swivel and tilt base stand
This monitor is intended for use in Health Care Facilities model AMM240EDwith air or with oxygen or nitrous oxide.For disposal of waste product, follow the requirement of local code.Electrical input rating: 24V DC 2.7AType of protection against electric shock: Class I Equipment.Degree of protection against the ingress of water: IP22 compliance.Mode of operation: ContinuousThis monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2 , in ad-dition to the medical requirements, has also been tested and found to comply with system complies with applicable EMC laws.Environmental conditions for transport and storage:-  Temperature range within -4°  to 140° F (-20° to 60°C)-  Relative humidity range within 10% to 85%-  Atmospheric pressure range within 500 to 1060 hPa.: UL approval mark according to thesafety standard for Medical equipment: Direct CurrentMEDICAL EQUIPMENTWITH RESPECT TO ELECTRIC SHOCK,FIRE AND MECHANICAL HAZARDS ONLYIN ACCORDANCE WITH ANSI/AAMI ES 60601-1 andCAN/CSA C22.2 No. 60601-1 Medical Equipment AMM240ED   27
28    User’s GuideElectromagnetic CompatibilityLike other electrical medical equipment, the AMM240ED requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the AMM240ED must be installed and operated according to the EMC information provided in this manual. Note   The AMM240ED has been designed and tested to comply with IEC 60601-1-2:2014 requirements for EMC with other devices. Caution   Portable and mobile RF communications equipment may affect the normal function of the AMM240ED. Warning   Do not use cables or accessories other than those provided with the AMM240ED, as this may result in increased electromagnetic emis-sions or decreased immunity to such emissions. Warning    If the AMM240ED is used adjacent to or stacked with other equipment, observe and verify normal operation of the AMM240ED in the a surgical procedure. Consult the tables below for guidance in placing the AMM240ED. The customer or the user of AMM240ED should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment - guidanceRF emissions CISPR 11 Group 1The Model AMM240ED uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipmentRF emissions CISPR 11 Class BAMM240ED is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposesHarmonic emissions IEC61000-3-2 Class AVoltage Fluctuations IEC61000-3-3 CompliesManufacturer’s declaration - electromagnetic emissionThe customer or the user of AMM240ED should assure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment - guidanceElectrostatic discharge (ESD) IEC61000-4-2                       ± 8 kV contact                        ± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV airFloors should be wood, concrete or ceramic tile. synthetic material, the relative humidity should be at least 30%.Electrical fast transient /burst IEC61000-4-4                       ± 2 kV100 kHz repetition frequencyMains power quality should be that of a typical commercial or hospital environment.Surge IEC61000-4-5                       ± 0,5 kV, ± 1 kV, ± 2 kVMains power quality should be that of a typical commercial or hospital environment.Manufacturer’s Declaration - Electromagnetic Immunity
Power frequency (50/60Hz) mag-netic eld IEC 61000-4-8 3.0 A/m50 Hz or 60 Hz3.0 A/m50 Hz or 60 HzPower frequency mag-netic elds should be at levels characteristic of a typical location in a typical commercial or hospital environment.Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-110 % UT ; 0,5 cycleAt 0° . 45°, 90°, 135°, 180°, 225°, 270°, and 315° q)Mains power quaility should be that of a typical commercial or hospital environment.  If the user of the AMM240ED image intensier requires con-tinued operation during power mains interrup-tions, it is recommended that the AMM240ED image intensier be powered from an uninter-ruptible power supply or a battery.0% UT; 1 cycle and70 % Ut ; 25/30 cyclesSingle phase: at 0°0 % Ut ; 250/300 cycleNote: Ut is the A.C. mains voltage prior to application of the test level.The Model AMM240ED is intended for use in the electromagnetic environment specied below. The customer or the user of AMM240ED should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment - guidanceConducted RFIEC61000-4-6Radiated RFIEC 61000-4-33 V0,15 MHz - 80 MHz6V in ISM and amature radio bands between 0,15 MHz and 80 Mhz80 % AM at 1 kHz10 V/m80 MHz - 2,7 GHz80% AM at 1 kHz3 V0,15 MHz - 80 MHz6V in ISM and amature radio bands between 0,15 MHz and 80 Mhz80 % AM at 1 kHz10 V/m80 MHz - 2,7 GHz80% AM at 1 kHzPortable and mobile RF communications equipment should be used no closer to any part of the AMM240ED, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.Recommended Separation Distance0.15 MHz to 80 MHz80 MHz to 800 MHz800 MHz to 2.5 GHzwhere P is the maximum oputput power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m).Field strengths from xed RF transmitters, as deter-mined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range (b).Interferency may occur in the vicinity of equipment marked with the follwing symbol:NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.NOTE 2: These guidelines may not apply in all situations.  Electromagnetic propagation is affected by absorption and             reection from structures, objects, and people.(a) Field strengths from xed transmitters, such as base stations for radio (cellular/cordless) telephones and land mo-bile radios, amateur radio, AM and FM radio broadcast and TV broadcast, cannot be predicted theoretically with accu-racy.  To assess the electromagnetic environment due to xed RF transmitters, an electromagnetic site survey should be considered.  If the measured eld strength in the location in which the AMM240ED is used exceeds the applicable RF compliance level above, the AMM240ED should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the AMM240ED.(b) Over the frequency range 150kHz to 80MHz, eld strengths should be less than [V1] V/m.Manufacturer’s Declaration - Electromagnetic ImmunityAMM240ED   29
30    User’s GuideRecommended Separation Distances Between Portable and Mobile RF Communications Equi-pement and the AMM240ED SystemThe AMM240ED system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the AMM240ED system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the AMM240ED system as recommended below, according to the maximum output power of the communications equipment.Rated maximum output power (W) of transmitterSeparation distance (m) according to frequency of transmitter150kHz to 80MHzd=1.17, p80MHz to 800MHzd=1.17, p800MHz to 2.5GHzd=2.33, p0.01 0.12 0.12 0.230.1 0.37 0.37 0.741 1.17 1.17 2.3310 3.70 3.70 7.37100 11.70 11.70 23.30For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in me-ters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reection from structures, objects, and people.Dimension Drawing (mm) of AC Adapter
AMM240ED   31Dimension Drawing (mm) of AMM240ED
32    User’s GuideConnectorsDC InputConnector Jack Power InputVideo Input24 Pin DVI-I In Connector.DDWG or Equivalent Connector.Pin Description Pin Description Pin Description1T.M.D.S. Data2- 9 T.M.D.S. Data1- 17 T.M.D.S. Data0-2 T.M.D.S. Data2+ 10T.M.D.S. Data1+18 T.M.D.S. Data0+3T.M.D.S. Data2 Shield 11 T.M.D.S. Data1 Shield 19 T.M.D.S. Data0 Shield4NC 12 NC 20NC5 NC 13 NC 21 NC6 DDC Clock 14 +5V Power 22 T.M.D.S. Clock Shield7 DDC Data 15 Ground (for +5V 23 T.M.D.S. Clock+8 NC 16 Hot Plug Detect 24 T.M.D.S. Clock-Pin Description Pin Description1 GND 4NC2GND 5 24V Input324V InputVideo Input24 Pin DVI-I Out Connector.DDWG or Equivalent Connector.Pin Description Pin Description Pin Description1T.M.D.S. Data2- 9 T.M.D.S. Data1- 17 T.M.D.S. Data0-2 T.M.D.S. Data2+ 10T.M.D.S. Data1+18 T.M.D.S. Data0+3T.M.D.S. Data2 Shield 11 T.M.D.S. Data1 Shield 19 T.M.D.S. Data0 Shield4NC 12 NC 20NC5 NC 13 NC 21 NC6 DDC Clock 14 +5V Power 22 T.M.D.S. Clock Shield7 DDC Data 15 Ground (for +5V 23 T.M.D.S. Clock+8 NC 16 Hot Plug Detect 24 T.M.D.S. Clock-Video Input HD/SD SDI1 IN Connector.Pin Description Pin Description1 SDI IN 2GNDVideo Input HD/SD SDI1 Out Connector.Pin Description Pin Description1 SDI Out 2GND
Signal Input USB Signal Connector.Pin Description Pin Description1Vcc(5V) 2 NC3 NC 4GNDVideo InputHD 15/RGBS IN Connector.Pin Description Pin Description Pin Description1 RED 6 GND-RED 11 GND2GREEN 7GND-GREEN12 DDC SDA3BLUE 8GND-BLUE 13 HSYNC(CS)4GND 9 G5V 14VSYNC5 GND 10 GND 15 DDC SCLSignal InputRS232C Signal Connector.Pin Description Pin Description1 NC 2RX3 TX 4NC5 GND 6 NC7 NC 8 NC9 NCVideo Input HD/SD SDI2 IN Video Connector.Pin Description Pin Description1 SDI Input 2GNDVideo Input Y/C IN Video Connector.Pin Description Pin Description1 GND 2GND3 Chroma_In 4 Luma_InAMM240ED   33
Description of WarrantyBARCO warrants to the rst Buyer (Buyer) that the product purchased when shipped in its original container will conform to BARCO specications, and to any BARCO approved specications furnished to BARCO by the Buyer, and will be free of defects in materials and workmanship. BARCO warrants that the product purchased is manufactured from new components which meet BARCO standards, quality and specications. Subject to the conditions and limitations set forth below, BARCO will, at its option, either repair any component of its products that prove defective by reason of improper workmanship or materials or BARCO has the exclusive right to replace with refurbished units or with an equivalent product.  BARCO warrants that the components used for repair, refurbished units or equivalent product will meet BARCO standards, quality and specications.Commencement and Duration of WarrantyThe product purchased will be warranted for a period of eighteen (18) months (excluding the LCD panel, touch screen, and the protection lter) from the date of shipment. LCD panels and touch screens are warranted for a period of twelve (12) months from the date of shipment. Protection lters are not warranted as damage to the protection lter is considered to be normal wear and tear and can be replaced at Buyer’s cost.Components used for repair, refurbished units or equivalent product will be warranted for a period of twelve (12) months from the date of repair. Limitation of WarrantyThis limited warranty does not cover any damage to this product or other non-BARCO products that results from any of the following: improper installation or operation; accident; abuse; misuse; natural disaster; war; insufcient or excessive electrical supply; abnormal mechanical or environmental conditions; any unauthorized disassembly, repair or modication; normal wear and tear;  tampering by anyone other than an BARCO engineer or an BARCO Authorized Service Center (ASC); the use of supplies, consumable items and conditions beyond the control of BARCO, such as common carrier provided equipment and/or facilities; operation of BARCO product in excess of the specications.  This limited warranty also does not apply to any product that has not been handled or packaged correctly, that has been sold as second-hand or has been resold contrary to the US export regulations, on which the original identication information (i.e. serial number, rating and/or warranty label) has been altered, obliterated or removed.34    User’s Guide
In WarrantyBARCO or its ASC will repair or replace if defective in material or workmanship without cost, for a period of eighteen (18) months, (LCD panels and touch screens for a period of twelve (12) months) after the date of shipment. Buyer must notify BARCO or its ASC of the defect before expiration of the warranty period, and request an RMA number.  If the conguration has been modied in any manner, the product must be returned to its original conguration before any warranty service will be performed by BARCO or its ASC. No goods are to be returned to BARCO or its ASC without prior authorization. Buyer will be responsible for packaging (preferably original container) and shipping the defective goods to BARCO or its ASC, shipping charges prepaid.BARCO or its ASC will return the in warranty product, at no cost to the buyer. AMM240ED   35
Out-of-WarrantyBARCO or its ASC will repair or replace if defective in material or workmanship with fee, any product which the warranty period has expired (out-of-warranty).Buyer must notify BARCO or its ASC of the defect and request an RMA number.  If the conguration has been modied in any manner, the product must be returned to its original conguration before any service will be performed by BARCO or its ASC. No goods are to be returned to BARCO or its ASC without prior authorization. Buyer will be responsible for packaging (preferably original container) and shipping the defective goods to BARCO or its ASC, shipping charges prepaid.BARCO or its ASC will return the out-of-warranty product, at cost to the buyer.Product End of Life (EOL)In the event of an RMA of an EOL product(s), BARCO will hold or store major components of its products for a period of ve (5) years, after the EOL of its products.  BARCO shall continue to perform the service of its products as long as BARCO holds or stores said components of the products, with reasonable charge.The forgoing Warranty and Out-of-Warranty terms apply.36    User’s Guide
DisclaimerTHE FORGOING IS THE COMPLETE WARRANTY FOR BARCO PRODUCTS AND SUPERSEDES ALL OTHER WARRANTIES AND REPRESENTATIONS, WHETHER ORAL OR WRITTEN.  EXCEPT AS EXPRESSLY SET FORTH ABOVE, NO OTHER WARRANTIES ARE MADE WITH RESPECT TO BARCO PRODUCTS AND BARCO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED HEREIN, INCLUDING, TO THE EXTENT PERMITTED BY APPLICABLE LAW, ANY WARRANTY THAT MAY EXIST UNDER NATIONAL, STATE, PROVINCIAL OR LOCAL LAW INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY ON NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARE LIMITED TO THE PERIODS OF TIME SET FORTH ABOVE.  SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY. BARCO’S TOTAL LIABILITY UNDER THIS OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, IS LIMITED TO REPAIR OR REPLACEMENT, AND ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY.  TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, BARCO SHALL NOT BE LIABLE TO THE PURCHASER OR END USER CUSTOMER OF AN BARCO PRODUCT FOR ANY DAMAGES, EXPENSES, LOST DATA, LOST REVENUES, LOST SAVINGS, LOST PROFITS, OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE PURCHASE, USE OR INABILITY TO USE THE BARCO PRODUCT, EVEN IF BARCO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.  SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY. THE LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR JURISDICTION TO JURISDICTION.AMM240ED   37
Barco, Inc.47817 Fremont Blvd. Fremont, CA 94538, USATel  : 1 510 490 1005Fax : 1 510 490 1151

Navigation menu