Document CreatorAdobe InDesign CC 2017 (Windows)

AUTO - SCANNING WITH DIGITAL CONTROL
LCD COLOR MEDICAL MONITOR
AMM240ED
Operation Manual
For future reference, record the serial number of your display
monitor in the space below :
Serial Number
The serial number is located on the back of the monitor
AMM240ED 1
Back of the Monitor
WARNING
The title «WARNING» is used to inform the users of possible causes that could inflict the injury, death, or property
damage to the patients.
CAUTION
The title «CAUTION» is used to inform the users of possible causes that could inflict the patients although it might
not severe enough to cause death.
NOTE
The title «NOTE» is used to inform the users of items that
are of importance in terms of installation, operation, or
maintenance of the Equipment although the failure does
not inflict the bodily harm to the patients.
Barco, Inc. 2017
All other trademarks are the property of their reference owners.
This document is subject to change without notice.
BARCO provides this information as reference only. Reference to other vendor’s
products does not imply any recommendation or endorsement.
Revision Control
Document number I-101117190001
Rev. A
2 User’s Guide
Table of Contents
Product Description and Intended Use....................................................... 3
Warnings and Cautions.............................................................................. 4
Symbol Definitions...................................................................................... 7
EU Declaration of Conformity for Medical Applications.............................. 8
Safety Precaution....................................................................................... 9
Cleaning the Monitor.................................................................................. 9
Recommendation to Use more than One Unit........................................... 9
On Burn-in.................................................................................................. 9
Power Management Function.................................................................... 10
Preset Modes.............................................................................................. 11
Video Signals.............................................................................................. 12
PIP / POP / PBP function........................................................................... 13
DDC............................................................................................................ 14
Installation.................................................................................................. 14
Connecting the Power Cord....................................................................... 15
User Function / Messages......................................................................... 16
OSD Section............................................................................................... 17
Troubleshooting.......................................................................................... 25
Specifications of (AMM240ED).................................................................. 26
Classification.............................................................................................. 27
Electromagnetic Compatibility.................................................................... 28
Dimension Drawing (mm) of AC Adapter.................................................... 30
Dimension Drawing (mm) of AMM240ED................................................... 31
Connectors................................................................................................. 32
Description of Warranty.............................................................................. 34
AMM240ED 3
Product Description and Intended Use
Please check the following items are present when you unpack the box, and save
the packing materials in case you will need to ship or transport the monitor in future.
• AMM240ED LCD Monitor (the equipment that displays information, graphic
data, image and video on the LED screen) and two video cables
(1) BNC x4 to HD15 Cable(1) DVI-I cable
•
AC Power cord*
•
AC-Adapter
CAUTION
Model No :BM060S24F06
(Bridgepower)
•
BNC Cable, and Y/C Cable.
•
DC extension cable (optional)
15ft length: Model 1501047***(Bridgepower)
75ft length: Model 1501047***(Bridgepower)
***: blank or 001~999
•
CD Multi-language Manual, English User Manual and 4pcs VESA screws
•
Cable Cover
•
Stand (optional)
33-329-085, SB-004W
*Might vary pending on region standard
4
User’s Guide
Warnings and Cautions
Please read this manual and follow its instructions carefully. The words warning,
caution, and note carry special meanings and should be carefully reviewed:
Warning
The personal safety of the patient or physician may be
involved. Disregarding this information could result in
injury to the patient or physician.
Caution
Special service procedures or precautions must be
followed to avoid damaging the instrument.
Note
Special information to make maintenance easier or important
information more clear.
An exclamation mark within a triangle is intended to alert the
user to the presence of important operating and maintenance
instructions in the literature accompanying the product.
A lightning bolt within a triangle is intended to warn of the
presence of hazardous voltage. Refer all service to authorized
personnel.
Warning
TO AVOID POTENTIAL SERIOUS INJURY TO THE USER
AND THE PATIENT AND/OR DAMAGE TO THIS DEVICE,
THE USER MUST :
Warranty is void if any of these warnings are disregarded.
Barco, Inc. accepts full responsibility for the effects on safety, reliability, and
performance of the equipment only if:
• Re-adjustments, modifications, and/or repairs are carried out exclusively
by Barco, Inc.
• The electrical installation of the relevant operating room complies with the
applicable IEC and CE requirements.
Warning
Federal law (United States of America) restricts this
device to use by, or on order of a physician.
The Barco, Inc. AMM240ED monitor has been tested under UL (ANSI/AAMI ES
60601-1) standard and UL listed for Medical application.
Barco, Inc. reserves the right to make improvements in the product(s) described
herein. Product(s), therefore, may not agree in detail to the published design
or specifications. All specifications are subject to change without notice. Please
contact Barco, Inc. directly or phone your local Barco, Inc. sales representative or
agent for information on changes and new products.
Warnings
AMM240ED 5
1. Read the operating manual thoroughly and be familiar with its contents prior to using
this equipment.
2. Carefully unpack the unit and check if any damage occurred during shipment.
3. Should any solid object or liquid fall into the panel, unplug the unit and have it checked
by qualified personnel before operating it any further.
4. Uplug the unit if it is not to be used for an extended period of time. To disconnect the
cord, pull it out by the plug. Never pull the cord itself.
5. Be a qualified physician, having complete knowledge of the use of this equipment.
6. Test this equipment prior to a medical procedure. This monitor was fully tested at the
factory before shipment.
7. Avoid removing covers on control unit to avoid electric shock.
8. Attempt no internal repairs or adjustments not specifically detailed in this operating
manual.
9. Pay close attention to the care, cleaning instructions in this manual. A deviation may
cause damage (refer to the Cleaning section).
10. DO NOT STERILIZE MONITOR.
11. Read the entire instruction manual before assembling or connecting the camera.
12. Do not place the monitor or any other heavy object on the power cord. Damage to the
cable can cause fire or electirc shock.
13. Monitor with power supply is suitable for use in patient environment.
14. DO NOT stack more than 3 boxes high
15. To avoid the risk of electric shock, this equipment must only be connected to a supply
mains with protective earth.
This equipment has been tested and found to comply with the limits for medical devices in
IEC 60601-1-2:2014. These limits are designed to provide reasonable protection against
harmful interference in a typical medical installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to other devices, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving device.
- Increase the separation between the equipment.
- Connect the equipment into an outlet on a circuit different from that to which the other
device(s) are connected.
- Consult the manufacturer or field service technician for help.
NOTICES TO USER
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipement generates or uses radio frequency energy. Changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment. The user could lose the authority to operate this equipment if an
unauthorized change or modification is made.
6
User’s Guide
Cautions
1. The AC Adapter must be plugged into a Grounded power outlet.
2. Use only the proprietary AMM240ED power supply for the
AMM240ED monitor. Make a proper connection by ensuring that the
shrink tubing completely secures the connection between the DC power cord and the
extension cord.
3. Turn power off when unit is not in use.
4. Never operate the unit right after having transported from a cold location directly to a
warm location.
5. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the
screen. Spray the cleaning solution into a soft cloth and clean gently.
6. Handle the monitor with care. Do not strike or scratch the screen.
7. Do not block the monitor cooling vents. The monitor is cooled by natural convection
and has no fan.
8. Do not force the monitor past 28 degrees of vertical when adjusting the screen
position. (For monitors equipped with stands only.)
9. Remove the power module and connection when transporting the unit.
10. Save the original carton and associated packing material. They will be useful should
you have to transport or ship the unit.
11. Allow adequate air circulation to prevent internal heat buildup.
12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains,
draperies) that may block the ventilation slots.
13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock.
14. The unit is designed for operation in a horizontal position. Never operate the unit in
a vertical position.
15. Keep the unit away from equipment with strong magnets (i.e. a large loudspeaker.)
16. Do not expose the monitor to moisture or excessive dust.
17. Equipment with SIP/SOP connectors should either comply with IEC 60601-1
harmonized national standard or the combination should be evaluated.
Do not touch the patient with signal input or output connectors.
18. Use only a hospital grade power supply cord.
19. This equipment has been tested and found to comply with the limit for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable generate uses and can radiate radio frequency energy, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation, which can be detemined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving device.
• Increase the separation distance between the equipment.
• Connect the equipment to an outlet on a circuit different from that to which the
other device(s) are connected.
• Consult the manufacturer or field service technican for help.
20. Grounding reliability can only be achieved when the equipment is connected to an
equipment receptacle labeled “Hospital Only” or “Hospital Grade.”
21. The products have lower breaking capacity type. So do not install at the building power
system prospective short-circuit current exceeding 35 A.
22. Disconnecting of the power cord from teh AC/DC Adapter is the proper means of isolation
from the supply mains.
Note
To connect to an international power supply, use a an attachment plug
appropriate for the power outlet.
Note
Refer to the “Electromagnetic Compatibility” (EMC) section of this manual to
ensure EMC. The AMM240ED must be installed and operated
according to the EMC information provided in this manual.
AMM240ED 7
Dangerous: High Voltage
Indicates Protective Earth
Ground.
Direct Current
For Indoor Use Only.
Serial Number
Tested to Comply with FCC
Class B Standards.
This Way Up
Stand-by
Fragile, Handle with Care
Tested to Comply with Japan
Stacking Limit by Number
Tested to Comply with China
Keep Dry
BSMI Mark for Taiwan
Approval
Recyclable
Mark for CU CountriesRussia,Kazakhstan, Belarus
See Accompanying Document
China RoHS symbol. Number
indicates EFUP(Environmental
Friendly Use Period) from the
date of manufacturing.
Indicates proof of conformity to applicable European
Economic Community Council
directives and to harmonized
standards published in the of-
Medical Equipment is in accordance with ANSI/AAMI ES 60601-1
and CAN/CSA C22.2 No. 60601-1
in regards to electric shock,
Communities.
Medical Equipment
hazards.
Authorized Representative in
Europe
Tested to Comply with IP
(Ingression Protection) Rating
Date of Manufacture
WEEE symbol for recyclable
product. Please do not throw
the product with this symbol in
the bin.
Manufacturer
8
User’s Guide
EU Declaration of Conformity for Medical Applications
A Declaration of Conformity has been filed for this product. A sample
of this document may be found in the addendum which accompanies
this manual. For a copy of the Declaration of Conformity document,
please contact Barco, Inc. and request the AMM240ED DOC.
Prepare to Unpack Monitor
Before you unpack your monitor, prepare a suitable workspace. You
need a stable and level surface near a grounded wall outlet in an area
which is relatively free of glare from sunlight or other sources of bright
light. The monitor is cooled by natural convection (it has no fan).
For optimum performance, do not block the cooling vents.
While unpacking the monitor, inspect it and other package contents
for shipping damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or transportation
company and contact customer service for monitor in case of return.
After you unpack the monitor, make sure the following items are included
• Monitor with video cable
• AC adapter with cable
CAUTION: AC Adapter must be plugged into Grounded a power outlet
CAUTION : AC adapter
Model No: BM060S24F06 (Bridgepower)
• This operation manual
Note: Your system provider may offer alternative cords or cables
depending on the installation requirement and local geography issues.
Safety Precaution
AMM240ED 9
·
Avoid placing the monitor, or any other heavy object, on the power cord
·
Do not expose the monitor to rain, excessive moisture, or dust to avoid
·
Do not cover the slots or openings of the monitor for proper heat
dissipation. Always put the monitor in a place where there is adequate
ventilation.
Avoid placing the monitor against a bright background or where sunlight
. Place the
monitor just below eye level.
Handle with care when transporting the monitor.
Refrain from giving the shock or scratch to the screen, as screen is
fragile.
Performance of preventive maintenance is not essential. Periodic maintenance
inspections are essential to keep the monitor in optimum condition and ensure
safe operation. We recommend a functional and safety test of the monitor at regular
intervals (e.g. at least once a year).
·
·
·
·
Cleaning the Monitor
However, we suggest to clean the monitor with non-abrasive cloths and cleaning
solutions used in hospitals to clean similar equipment. We recommend using 70%
isopropyl alcohol for the screen surface and warm water and a mild detergent for all
other surfaces. Other acceptable cleaning agents are listed below:
• 70% isopropyl alcohol
• Cidex (2.4% glutaraldehyde solution)
• 0.5% Chlorhexidine in 70% isopropyl alcohol
To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away
from the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag.
Recommendation to Use More Than One Unit
As unforeseen situations can occasionally occur for the monitor, when the display
is used please use a safety control. It is strongly recommended you use more than
one unit or prepare a spare unit in case there is an emergency.
On Burn-in
Permanent burn-in may occur from the following:
• Displaying color bar or static images repeatedly or for a long period of time.
• Using the unit repeatedly in a high temperature/ high humidity environment
• Displaying an image smaller than the monitor continuously.
To reduce the risk of burn- in, it is recommended to turn off the power of the unit,
and reduce the brightness when the unit is not in use.
10
User’s Guide
Power Management Function
The monitor is equipped with the power management function which automatically
reduces the power consumption when not in use in three power level modes.
•
Stand-by Mode
The monitor goes into stand-by mode when the horizontal sync signal is off for
about 10 seconds. In this mode, the screen goes off and the power LED blinks
for 1 second On and 1 second Off. The screen is displayed after the horizontal
sync signal is restored.
•      Suspend Mode
The monitor goes into suspend mode when the vertical sync signal is off for
about 10 seconds. The power consumption during this is 10 W. In this mode,
the screen goes off and the power LED blinks for 1 second On and 1 second
Off. The screen is displayed after the vertical sync signal is restored.
•
Off Mode
The monitor goes into power-off mode when the vertical and horizontal sync
signals are off for about 10 seconds. In this mode, the screen goes off and the
power LED blinks for 1 second On and 1 second Off. The screen is displayed
after the vertical and horizontal sync signals are restored.
Power Management System
The AMM240ED Medical Monitor power management proposal provides four
phases of power saving modes by detecting the horizontal sync signal as shown in
the table below.
State
Normal
Operation
DPMS
Standby
DPMS
Suspend
DPMS Off
Horizontal Sync
Active
Inactive
Active
Inactive
Vertical Sync
Active
Active
Inactive
Inactive
Video
Active
Blanked
Blanked
Blanked
Power Indicator
Green
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Green Flashing (1
sec. Interval)
Power
Consumption
40W
15W
15W
15W
When the monitor is power saving mode or detects an incorrect timing, the screen
will be blank and power LED indicator will blink.
AMM240ED 11
PRESET MODES
Input Signal Timing
Resolution
Horizontal
frequency
( KHz )
Vertical
frequency
( Hz )
Pixel clock
( MHz )
640 x 350 @70Hz
31.469
70.087
25.175
640 x 480 @60Hz
31.469
59.940
25.175
640 x 480 @75Hz
37.500
75.000
31.500
800 x 600 @56Hz
35.156
56.250
36.000
800 x 600 @60Hz
37.879
60.317
40.000
800 x 600 @75Hz
46.875
75.000
49.500
1024 x 768 @60Hz
48.363
60.004
65.000
1024 x 768 @70Hz
56.476
70.069
75.000
1024 x 768 @75Hz
60.023
75.029
78.750
1152 x 864 @60Hz
54.348
60.053
80.000
1152 x 864 @70Hz
63.955
70.016
94.200
1152 x 864 @75Hz
67.500
75.000
108.000
1280 x 1024 @60Hz
63.981
60.02
108.000
1680 x 1050 @60Hz
64.742
59.946
119.125
1680 x 1050 @60Hz
65.160
59.944
147.000
1600 x 1200 @60Hz
74.077
59.981
130.375
1920 x 1080@60Hz
67.500
60.00
148.500
1920 x 1200@60Hz
74.099
59.999
154.125
12
User’s Guide
Video Signals
Component/RGBs
Format
DVI-I
HD-15
Y/C
NTSC-M
NTSC-443
PAL-BDGHI
PAL-M
PAL-N
PAL-60
480/59.94i
SDI1
SDI2
480/59.94p
Y/Pb/Pr/
RGB+SOG
576/50i
576/50p
720/50p
720/59.94p
720/60p
RGB+
CS
1080/23.98p
1080/24p
1080/25p
1080/29.97p
1080/30p
1080/50i
1080/59.94i
1080/60i
1080/50p
1080/60P
AMM240ED 13
PIP / POP / PBP Function*
The following combination options are available to you:
PIP
DVI-I
SDI1
SDI2
(Optional)
Component /
RGBs
HD-15
Y/C
DVI-I
SDI 1
SDI 2
(Optional)
Component/
RGBs
HD-15
Y/C
Main
*When the frame frequency of the main screen is different from that of the sub screen, the picture may
be disturbed.
*When both main and sub screens input interlace signals, the picture may be disturbed.
14
User’s Guide
DDC
To make your installation easier, the monitor is able to Plug and Play with your
system if your system also supports DDC protocol. The DDC (Display Data
Channel) is a communication protocol through which the monitor automatically
informs the host system about its capabilities, for example, supported resolutions
and corresponding timing. The monitor supports DDC1 and DDC2B standard.
Installation
To install the monitor to your host system, please follow the steps as given below:
Steps
1. Use the supplied video cable (DVI-I, Y/C, BNC, BNCx4 to HD15) then connect to
the
host system accordingly.
2. Connect the DC power to the DC power connector on the monitor.
3. Connect one end of AC power cord into the AC Adapter and the other end to AC
power outlet.
4. Then turn the host system on and then the monitor.
5. If the monitor still does not function properly, please refer to the troubleshooting
section to diagnose the problem.
HD/SD SDI1 OUT
DC Power
RS232C
HD15/RGBS IN
HD/SD SDI1 IN
DVI-I OUT DVI-I IN
USB
Y/C IN
HD/SD SDI2 IN
Connecting the Power Cord
AMM240ED 15
the area.
* This monitor has an universal AC adapter that allows operation in either
AC 100 - 240 V ac voltage area. No user-adjustment is required.
* Plug one end of the power cord to the AC adapter, plug another end to a proper
AC outlet.
The cord set should have the appropriate safety approvals for the country in which
the equipment will be installed and marked HAR.
For 120 volt Applications, use only the UL Listed detachable power cord with NEMA
(tandem blades) plug cap.
Hospital-grade
power cord
Extension power cord (optional)
15ft length: Model 1501047***(Bridgepower)
75ft length: Model 1501047***(Bridgepower)
***: blank or 001~999
Power Supply
Model No: BM060S24F06
AMM240ED
16
User’s Guide
User Functions / Messages
Key Name and Function
Power : Turns ON/OFF the system.
Menu : Enter /Exit OSD menu.
Left : Decrease setting/Value.
Right : Increase setting/value. Enter Sub menu
Up : Move to previos item.
Down : Move to next time.
Select : Select item.
Brightness : Quick key for brightness adjustment.
Contrast : Quick key for contrast adjustment.
Scale Mode : Quick key for scale mode adjustment
Input: Activate the video source selection menu.
Power Switch
How to Access the Menu.
1. Press the Menu button to activate the OSD menu.
2. Press the Up or Down button to select icons. The icon will be
highlighted when selected.
3. Press the right arrow button to go into another OSD menu.
4. Press the enter button to select sub menu and the right arrow or left arrow button
to select the function.
5. In order to exit from the OSD menu, choose the “Exit” icon. Press the menu button, then it will completely exit from the menu regardless of where you are.
6. Press the input button to enter the input menu. Push the Up or Down arrow to
highlight the correct input and press enter to select the input.
AMM240ED 17
OSD Section
Main Menu
Chromatic
Adjust Color Temp, Gamma
Visual		
Adjust Brightness, Contrast, Phase, Chroma,
Sharpness-V, Sharpness-H
Setting
Adjust Scale Mode, Color Space, Freeze Frame,
Zoom / Pan, PIP, POP, PBP
Advanced
Adjust OSD Position Control, Screen Control, DPMS, Auto
Source Select, Smart Select, Restore Factory, Key Lock,
		Overscan
Information
User Customer Entry, Serial Number, Runtime, Input Format,
		Exit
18
User’s Guide
OSD Section
Chromatic
Color Temp
Change the Color Temperature - D65, D93, SYS-1, SYS-2
		Red
0~100
		Green
0~100
		Blue
0~100
Gamma		
Change the Gamma Value - 1.8, 1.9, 1.95, 2.1, 2.1S, 2.2, 2.3,
2.4, 2.4S, S0, Radiograph
Exit		
Exit the Menu
Visual
Brightness
Adjust the Brightness of Panel (Range 0 - 100)
Contrast		
Adjust the Contrast of Video (Range 0 - 100)
Phase		
Adjust the Phase of Video (Range 0 - 100)
		*Available for Y/C and HD/SD SDI1 only
Chroma
Adjust the Chroma of Video (Range 0 - 100)
*Available for Y/C and HD/SD SDI1 only
Sharpness-V
Set the Sharpness of Vertical Image (Range 0 - 20)
Sharpness-H
Set the Sharpness of Horizontal Image (Range 0 - 20)
Exit		
Exit the Menu
AMM240ED 19
OSD Section
Setting
Scale Mode
Change the Scale Mode - Fill all, One to One,
Vertical - Fill, Horizontal - Fill, Fill aspect ratio
Color Space
Change Color Space Between RGB and YUV
Freeze Frame
Off / On Freeze Frame
Zoom / Pan
Activate zoom/pan OSD
PIP		
Activate PIP Menu
POP		
Activate POP Menu
PBP		
Activate PBP Menu
Exit		
Exit the Menu
20
User’s Guide
OSD Section
Sub menu of PIP
Mode		
PIP Mode ON / OFF
Source		
PIP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2
Component/RGBs, HD15, Y/C
Position		
PIP Sub Screen Position - Top L, Top R, Bottom L, Bottom R
Size
PIP Sub Screen Size - Small, Medium, Large
Blending		
PIP Sub Screen Blending (Range 0 - 20)
Swap		
PIP Sub Screen Swap
Exit		
Exit the Menu
Sub menu of PBP
Mode		
PBP Mode ON / OFF
Source		
PBP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2
Component/RGBs, HD15, Y/C
Swap		
PBP Sub Screen Swap
Exit		
Exit the Menu
AMM240ED 21
OSD Section
Sub menu of POP
Mode		
POP Mode ON / OFF
Source		
POP Sub Screen Source - DVI-I, HD/SD SDI1, HD/SD SDI2
Component/RGBs, HD15, Y/C
Position		
POP Sub Screen Position - Top L, Top R, Bottom L, Bottom R
Size
POP Sub Screen Size - Small, Medium, Large
Blending		
POP Sub Screen Blending (Range 0 - 20)
Swap		
POP Sub Screen Swap
Exit		
Exit the Menu
22
User’s Guide
OSD Section
Advanced
OSD Position
Change the OSD Menu - H and V Position, Background,
Control
OSD Time Out, Language
Screen Control
Control and Adjust H and V position, Freqency, Phase,
Noise Reduction, Motion Offset
DPMS
Change the DPMS - Off, 60 min, 90 min, 120 min, Normal
Auto Source
Adjust Auto Source Select Between On and Off
Select
Smart Select
Enable / Disable Smart Select Sub Menu - Model A, Model B
Model C, Model D
Restore Factory Changes All OSD Value to Factory Outgoing Status
(associated with the Color Temperatures are factory calibrated
with a consequent reduction of the maximum luminance compared
to Native Color Temperature.)
Key Lock
Set to Key Lock Mode
Overscan
Adjust Overscan Ratio - Off, Step 1, Step 2, Step 3, Step 4,
Step 5, Step 6, Step 7
Exit
Exit the Menu
AMM240ED 23
OSD Section
Sub Menu of OSD Control
H-position
Adjust OSD H - Position (Range 0 - 100)
V-position
Adjust OSD V - Position (Range 0 - 100)
Back ground
Adjust Transparency of OSD Background (Range 0 - 20)
OSD Timeout
Adjust OSD timeout - 5s, 10s, 15s, 20s, 1m, 2m
Language
OSD Language - English, Japanese, Chinese, Korean,
		French, German
Exit		
Exit the Menu
Sub menu of Screen Control
H-Position
Adjust Screen H - Position (Range 0 - 100)
		*Available for HD15, HD/SD SDI1 Component/RGBs
V-Position
Adjust screen V - Position (Range 0 - 100)
		*Available for HD15, HD/SD SDI1 Component/RGBs
Frequency
Adjust Frequency (Range 0 - 100)
		*Available for HD15
Phase
Adjust Phase (Range 0 - 100)
		*Available for HD15
Noise		
Noise Reduction (Range 0 - 31)
Reduction
Motion Offset
Motion Offset (Range 0 - 100)
Exit		
Exit the Menu
24
User’s Guide
OSD Section
Information
Custom Entry
Change the User or Monitor’s Name
Custom Entry Row 1, Custom Entry Row 2
SN		
Display the Serial Number
Runtime
Display the Total Runtime
Input Format
Display the Current input Resolution and Vertical Frequency
Exit		
Exit the Menu
AMM240ED 25
TROUBLESHOOTING
Before sending your LCD monitor for servicing, please check the troubleshooting
list below to see if you can self-diagnose the problem.
Problems
Current Status
Remedy
No Picture
Power LED ON
· Using OSD, adjust brightness and
contrast to maximum or reset to their
default settings.
Power LED OFF
· Check the Standby Power Button and
Power switch.
· Check if AC power cord is properly
connected to the AC adapter.
Power LED Blinking
· Check if video signal cable is properly
connected at the back of monitor.
· Check if the power to computer system
is ON.
Abnormal Picture
Unstable Picture
· Check if the specification of graphics
adapter and monitor is in compliance
which may be causing the input signal
frequency mismatch.
Display is missing, center shift,
or too small or too large in
display size
· Using the Screen Control Menu, adjust
the Phase, Frequency, Horizontal, and
Vertical settings in order to correct the
display image.
26
User’s Guide
Specification*
Model
AMM240ED
Diagonal
Resolution
Pixel Pitch
Display Color
Viewing Angle
Brightness
Contrast ratio
Dimension
Color Gamut
LCD Response Time
24.07 inches (611.32) diagonal
1920 (H) x 1200 (V) @ 60hz
0.270mm x 0.270mm
16.7M colors
H: 178°, V: 178°
300 cd/m² (typical)
1000:1 (typical)
570 (W) x 386.8 (H) x 63.2 (D) mm
sRGB 100%
14msec (Typ.)
Input
HD/SD SDI 1
HD15
Component/RGBs
Y/C
BNC x 1
0.27~2.97Gb/s Serial input data
rate
500~1100mVp-p Serial input
swing
15p D-Sub (female)
Video: 0.7 ± 0.1 VP-p
H/V Sync: TTL Level (V high
≥2.3V, V low ≤0.5V)
Horizontal Frequency 30~80KHz
Vertical Frequency 50~85Hz
HD/SD SDI 2
(optional)
DVI-I
TMDS Level
MAX. 162MHz
MAX. 162MHz
15p D-Sub (female) (BNCx4 to
HD15 Cable
Output
RGB: 0.7 ± 0.1 Vp-p
HD/SD SDI
Composite Sync : 0.3Vp-p ~ 5Vpp H/V SYNC : TTL Level
Mini Din 4-pin
NTSC, PAL Color standard
Luminance : 1.0± 0.1VP (Video
:0.7Vp-p / Sync : 0.3Vp-p) Chrominance : 0.3 ± 0.03Vp-p
BNC x 1
0.27~2.97Gb/s Serial input
data rate
720~880mVp-p Serial input
Voltage swing
DVI-I 24+5 pin (female)
BNC x 1 ( 75 ohm ±5% )
DVI-I
0.27~2.98Gb/s Serial output
data rate
350~600mVp-p Serial output
swing
DVI-I 24+5 pin (female)
TMDS Level
MAX. 162MHz
General
Power Adaptor
Power Consumption
Package Dimension
Weight
VESA Mounting
AC 100 ~ 240V 50-60Hz
DC 24V, 2.7A
40W
665 x 240 x 640 (H)
Monitor : 7.35Kg (Without cable cover, Without stand)
AC adaptor : 410g
75mm x 100mm
Operating/Storage Environment
Operating Tempera50° ~ 104°F (10° - 40°C)
ture
Operating Humidity
25% ~ 75%, non-condensing
Storage Temperature
-0° ~ 140°F (-18° - 60°C)
Storage Humidity
15 ~ 90%RH (without condensation)
Compliance &Certification
Safety
UL(ANSI/AAMI ES 60601-1), cUL(CAN/CSA-C22.2 No. 60601-1), CE(EN 60601-1, IEC
60601-1), AS/NZS 3200-1-0, CCC(GB4943.1), CB-ITE (IEC 60950-1), IP22 Compliance
EMC
FCC(Part 15 Class B), CE(EN 60601-1-2, IEC 60601-1-2), AS/NZS 3200-1-2, VCCI(Class
B), CCC(GB9254, GB17625.1)
Optional Module
DC Extension Cable
5ft, 15ft, 75ft length
Base Stand
Adjustable high, swivel and tilt base stand
* All contents are subject to change without notice.
**Brightness shown is without touch screen or A/R filter installed.
AMM240ED 27
: Direct Current
Medical Equipment
MEDICAL EQUIPMENT
WITH RESPECT TO ELECTRIC SHOCK,
FIRE AND MECHANICAL HAZARDS ONLY
IN ACCORDANCE WITH
ANSI/AAMI ES 60601-1 and
CAN/CSA C22.2 No. 60601-1
: UL approval mark according to the
safety standard for Medical equipment
This monitor is intended for use in Health Care Facilities model AMM240ED
with air or with oxygen or nitrous oxide.
For disposal of waste product, follow the requirement of local code.
Electrical input rating: 24V DC 2.7A
Type of protection against electric shock: Class I Equipment.
Degree of protection against the ingress of water: IP22 compliance.
Mode of operation: Continuous
This monitor has been tested to comply with IEC/EN 60601-1, IEC/EN60601-1-2
, in addition to the medical requirements, has also been tested and found to comply with
system complies with applicable EMC laws.
Environmental conditions for transport and storage:
Temperature range within -4° to 140° F (-20° to 60°C)
Relative humidity range within 10% to 85%
Atmospheric pressure range within 500 to 1060 hPa.
28
User’s Guide
Electromagnetic Compatibility
Like other electrical medical equipment, the AMM240ED requires special precautions
to ensure electromagnetic compatibility with other electrical medical devices. To ensure
electromagnetic compatibility (EMC), the AMM240ED must be installed and operated
according to the EMC information provided in this manual.
Note
The AMM240ED has been designed and tested to comply with IEC 60601-12:2014 requirements for EMC with other devices.
Caution Portable and mobile RF communications equipment may affect
the normal function of the AMM240ED.
Warning Do not use cables or accessories other than those provided
with the AMM240ED, as this may result in increased electromagnetic emissions or decreased immunity to such emissions.
Warning If the AMM240ED is used adjacent to or stacked with other
equipment, observe and verify normal operation of the AMM240ED in the
a surgical procedure.
Consult the tables below for guidance in placing the AMM240ED.
Manufacturer’s declaration - electromagnetic emission
The customer or the user of AMM240ED should assure that it is used in such an environment.
Emission test
Compliance
RF emissions CISPR 11
Group 1
RF emissions CISPR 11
Class B
Harmonic emissions
IEC61000-3-2
Class A
Voltage Fluctuations
IEC61000-3-3
Complies
Electromagnetic environment - guidance
The Model AMM240ED uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not
likely to cause any interference in nearby electronic equipment
AMM240ED is suitable for use in all establishments, including
domestic establishments and those directly connected to the
public low-voltage power supply network that supplies buildings
used for domestic purposes
Manufacturer’s Declaration - Electromagnetic Immunity
The customer or the user of AMM240ED should assure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
Compliance Level
Electromagnetic
environment - guidance
Floors should be wood,
concrete or ceramic tile.
Electrostatic discharge
(ESD)
IEC61000-4-2
± 8 kV contact
± 2 kV, ± 4 kV, ± 8 kV, ± 15 kV air
Electrical fast transient
/burst IEC61000-4-4
± 2 kV
100 kHz repetition frequency
Mains power quality
should be that of a typical
commercial or hospital
environment.
Surge
IEC61000-4-5
± 0,5 kV, ± 1 kV, ± 2 kV
Mains power quality
should be that of a typical
commercial or hospital
environment.
synthetic material, the relative
humidity should be at least
30%.
AMM240ED 29
Power frequency
(50/60Hz) magnetic field
IEC 61000-4-8
3.0 A/m
50 Hz or 60 Hz
Power frequency magnetic fields should be
at levels characteristic
of a typical location in
a typical commercial or
hospital environment.
3.0 A/m
50 Hz or 60 Hz
Mains power quaility
should be that of a typical
commercial or hospital
environment. If the user
of the AMM240ED image
intensifier requires continued operation during
power mains interruptions, it is recommended
that the AMM240ED
image intensifier be
powered from an uninterruptible power supply or
a battery.
0 % UT ; 0,5 cycle
At 0° . 45°, 90°, 135°, 180°, 225°, 270°, and 315° q)
0% UT; 1 cycle
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines IEC61000-4-11
and
70 % Ut ; 25/30 cycles
Single phase: at 0°
0 % Ut ; 250/300 cycle
Note: Ut is the A.C. mains voltage prior to application of the test level.
Manufacturer’s Declaration - Electromagnetic Immunity
The Model AMM240ED is intended for use in the electromagnetic environment specified below.
The customer or the user of AMM240ED should ensure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
Compliance Level
Electromagnetic environment guidance
Portable and mobile RF communications
equipment should be used no closer to
any part of the AMM240ED, including
cables, than the recommended separation
distance calculated from the equation
applicable to the frequency of the
transmitter.
3V
3V
0,15 MHz - 80 MHz
0,15 MHz - 80 MHz
Conducted RF
IEC61000-4-6
6V in ISM and amature
radio bands between 0,15
MHz and 80 Mhz
6V in ISM and amature
radio bands between
0,15 MHz and 80 Mhz
Radiated RF
IEC 61000-4-3
80 % AM at 1 kHz
80 % AM at 1 kHz
10 V/m
10 V/m
80 MHz - 2,7 GHz
80 MHz - 2,7 GHz
80% AM at 1 kHz
80% AM at 1 kHz
Recommended Separation Distance
0.15 MHz to 80 MHz
80 MHz to 800 MHz
800 MHz to 2.5 GHz
where P is the maximum oputput power
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and d is the recommended separation
distance in meters (m).
Field strengths from fixed RF transmitters,
as deter-mined by an electromagnetic
site survey (a), should be less than the
compliance level in each frequency range
(b).Interferency may occur in the vicinity
of equipment marked with the follwing
symbol:
NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast, cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should
be considered. If the measured field strength in the location in which the AMM240ED is used exceeds the applicable
RF compliance level above, the AMM240ED should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as reorienting or relocating the AMM240ED.
(b) Over the frequency range 150kHz to 80MHz, field strengths should be less than [V1] V/m.
30
User’s Guide
Recommended Separation Distances Between Portable and Mobile RF Communications Equipement and the AMM240ED System
The AMM240ED system is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The user of the AMM240ED system can help prevent electromagnetic
interference by maintaining a minimum distance between portable and mobile RF communications
equipment (transmitters) and the AMM240ED system as recommended below, according to the maximum
output power of the communications equipment.
Separation distance (m) according to frequency of transmitter
Rated maximum output
power (W) of transmitter
150kHz to 80MHz
d=1.17, p
80MHz to 800MHz
d=1.17, p
800MHz to 2.5GHz
d=2.33, p
0.01
0.12
0.12
0.23
0.1
0.37
0.37
0.74
1.17
1.17
2.33
10
3.70
3.70
7.37
100
11.70
11.70
23.30
For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum
output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects, and people.
Dimension Drawing (mm) of AC Adapter
Dimension Drawing (mm) of AMM240ED
AMM240ED 31
32
User’s Guide
Connectors
DC Input
Connector Jack Power Input
Pin
Description
Pin
Description
GND
NC
GND
24V Input
24V Input
Video Input
24 Pin DVI-I In Connector.
DDWG or Equivalent Connector.
Pin
Description
Pin
Description
Pin
Description
T.M.D.S. Data2-
T.M.D.S. Data1-
17
T.M.D.S. Data0-
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
T.M.D.S. Data2 Shield
11
T.M.D.S. Data1 Shield
19
T.M.D.S. Data0 Shield
NC
12
NC
20
NC
NC
13
NC
21
NC
DDC Clock
14
+5V Power
22
T.M.D.S. Clock Shield
DDC Data
15
Ground (for +5V
23
T.M.D.S. Clock+
NC
16
Hot Plug Detect
24
T.M.D.S. Clock-
Video Input
24 Pin DVI-I Out Connector.
DDWG or Equivalent Connector.
Pin
Description
Pin
Description
Pin
Description
T.M.D.S. Data2-
T.M.D.S. Data1-
17
T.M.D.S. Data0-
T.M.D.S. Data2+
10
T.M.D.S. Data1+
18
T.M.D.S. Data0+
T.M.D.S. Data2 Shield
11
T.M.D.S. Data1 Shield
19
T.M.D.S. Data0 Shield
NC
12
NC
20
NC
NC
13
NC
21
NC
DDC Clock
14
+5V Power
22
T.M.D.S. Clock Shield
DDC Data
15
Ground (for +5V
23
T.M.D.S. Clock+
NC
16
Hot Plug Detect
24
T.M.D.S. Clock-
Video Input
HD/SD SDI1 IN Connector.
Pin
Description
Pin
Description
SDI IN
GND
Video Input
HD/SD SDI1 Out Connector.
Pin
Description
Pin
Description
SDI Out
GND
AMM240ED 33
Video Input
HD 15/RGBS IN Connector.
Pin
Description
Pin
Description
Pin
Description
RED
GND-RED
11
GND
GREEN
GND-GREEN
12
DDC SDA
BLUE
GND-BLUE
13
HSYNC(CS)
GND
G5V
14
VSYNC
GND
10
GND
15
DDC SCL
Signal Input
RS232C Signal Connector.
Pin
Description
Pin
Description
NC
RX
TX
NC
GND
NC
NC
NC
NC
Signal Input
USB Signal Connector.
Pin
Description
Pin
Description
Vcc(5V)
NC
NC
GND
Video Input
HD/SD SDI2 IN Video Connector.
Pin
Description
Pin
Description
SDI Input
GND
Description
Pin
Description
GND
GND
Chroma_In
Luma_In
Video Input
Y/C IN Video Connector.
Pin
34
User’s Guide
Description of Warranty
BARCO warrants to the first Buyer (Buyer) that the product purchased when
shipped in its original container will conform to BARCO specifications, and to any
BARCO approved specifications furnished to BARCO by the Buyer, and will be
free of defects in materials and workmanship. BARCO warrants that the product
purchased is manufactured from new components which meet BARCO standards,
quality and specifications.
Subject to the conditions and limitations set forth below, BARCO will, at its option,
either repair any component of its products that prove defective by reason of
improper workmanship or materials or BARCO has the exclusive right to replace
with refurbished units or with an equivalent product. BARCO warrants that the
components used for repair, refurbished units or equivalent product will meet
BARCO standards, quality and specifications.
Commencement and Duration of Warranty
The product purchased will be warranted for a period of eighteen (18) months
(excluding the LCD panel, touch screen, and the protection filter) from the date of
shipment.
LCD panels and touch screens are warranted for a period of twelve (12) months
from the date of shipment.
Protection filters are not warranted as damage to the protection filter is considered
to be normal wear and tear and can be replaced at Buyer’s cost.
Components used for repair, refurbished units or equivalent product will be
warranted for a period of twelve (12) months from the date of repair.
Limitation of Warranty
This limited warranty does not cover any damage to this product or other nonBARCO products that results from any of the following: improper installation
or operation; accident; abuse; misuse; natural disaster; war; insufficient or
excessive electrical supply; abnormal mechanical or environmental conditions; any
unauthorized disassembly, repair or modification; normal wear and tear; tampering
by anyone other than an BARCO engineer or an BARCO Authorized Service Center
(ASC); the use of supplies, consumable items and conditions beyond the control of
BARCO, such as common carrier provided equipment and/or facilities; operation
of BARCO product in excess of the specifications. This limited warranty also does
not apply to any product that has not been handled or packaged correctly, that has
been sold as second-hand or has been resold contrary to the US export regulations,
on which the original identification information (i.e. serial number, rating and/or
warranty label) has been altered, obliterated or removed.
AMM240ED 35
In Warranty
BARCO or its ASC will repair or replace if defective in material or workmanship
without cost, for a period of eighteen (18) months, (LCD panels and touch screens
for a period of twelve (12) months) after the date of shipment.
Buyer must notify BARCO or its ASC of the defect before expiration of the warranty
period, and request an RMA number. If the configuration has been modified in
any manner, the product must be returned to its original configuration before any
warranty service will be performed by BARCO or its ASC. No goods are to be
returned to BARCO or its ASC without prior authorization. Buyer will be responsible
for packaging (preferably original container) and shipping the defective goods to
BARCO or its ASC, shipping charges prepaid.
BARCO or its ASC will return the in warranty product, at no cost to the buyer.
36 User’s Guide
Out-of-Warranty
BARCO or its ASC will repair or replace if defective in material or workmanship with
fee, any product which the warranty period has expired (out-of-warranty).
Buyer must notify BARCO or its ASC of the defect and request an RMA number. If
the configuration has been modified in any manner, the product must be returned to
its original configuration before any service will be performed by BARCO or its ASC.
No goods are to be returned to BARCO or its ASC without prior authorization. Buyer
will be responsible for packaging (preferably original container) and shipping the
defective goods to BARCO or its ASC, shipping charges prepaid.
BARCO or its ASC will return the out-of-warranty product, at cost to the buyer.
Product End of Life (EOL)
In the event of an RMA of an EOL product(s), BARCO will hold or store major
components of its products for a period of five (5) years, after the EOL of its
products. BARCO shall continue to perform the service of its products as long as
BARCO holds or stores said components of the products, with reasonable charge.
The forgoing Warranty and Out-of-Warranty terms apply.
AMM240ED 37
Disclaimer
THE FORGOING IS THE COMPLETE WARRANTY FOR BARCO PRODUCTS
AND SUPERSEDES ALL OTHER WARRANTIES AND REPRESENTATIONS,
WHETHER ORAL OR WRITTEN. EXCEPT AS EXPRESSLY SET FORTH ABOVE,
NO OTHER WARRANTIES ARE MADE WITH RESPECT TO BARCO PRODUCTS
AND BARCO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED
HEREIN, INCLUDING, TO THE EXTENT PERMITTED BY APPLICABLE LAW, ANY
WARRANTY THAT MAY EXIST UNDER NATIONAL, STATE, PROVINCIAL OR
LOCAL LAW INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY ON
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, ARE
LIMITED TO THE PERIODS OF TIME SET FORTH ABOVE. SOME STATES
OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED
WARRANTIES OR LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY
LASTS, SO THE ABOVE LIMITATIONS MAY NOT APPLY.
BARCO’S TOTAL LIABILITY UNDER THIS OR ANY OTHER WARRANTY,
EXPRESSED OR IMPLIED, IS LIMITED TO REPAIR OR REPLACEMENT, AND
ARE THE SOLE AND EXCLUSIVE REMEDIES FOR BREACH OF WARRANTY
OR ANY OTHER LEGAL THEORY. TO THE FULLEST EXTENT PERMITTED
BY APPLICABLE LAW, BARCO SHALL NOT BE LIABLE TO THE PURCHASER
OR END USER CUSTOMER OF AN BARCO PRODUCT FOR ANY DAMAGES,
EXPENSES, LOST DATA, LOST REVENUES, LOST SAVINGS, LOST PROFITS,
OR ANY OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM
THE PURCHASE, USE OR INABILITY TO USE THE BARCO PRODUCT, EVEN
IF BARCO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
SOME STATES OR OTHER JURISDICTIONS DO NOT ALLOW THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE
ABOVE LIMITATIONS MAY NOT APPLY.
THE LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU
MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR
JURISDICTION TO JURISDICTION.
Barco, Inc.
47817 Fremont Blvd. Fremont, CA 94538, USA
Tel : 1 510 490 1005
Fax : 1 510 490 1151

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Create Date                     : 2017:11:30 09:07:10-08:00
Creator                         : Adobe InDesign CC 2017 (Windows)
Modify Date                     : 2018:01:12 12:15:37+09:00
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.2-c063 53.351735, 2008/07/22-18:11:12
Instance ID                     : uuid:a53114bb-3032-4ba3-881b-94ed57f06a9d
Original Document ID            : adobe:docid:indd:04820b23-dec4-11de-9bf3-8358dd57a9a2
Document ID                     : xmp.id:023cee5c-87b3-b447-be01-676e46c7b7fb
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:796da058-35bf-8346-916b-432043e44e84
Derived From Document ID        : xmp.did:3bc3bd23-358f-444b-90dd-c62c15354842
Derived From Original Document ID: adobe:docid:indd:04820b23-dec4-11de-9bf3-8358dd57a9a2
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Windows)
History Changed                 : /
History When                    : 2017:11:30 09:07:10-08:00
Metadata Date                   : 2018:01:12 12:15:37+09:00
Creator Tool                    : Adobe InDesign CC 2017 (Windows)
Thumbnail Width                 : 180
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 16103 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : True
Max Page Size W                 : 176.000110
Max Page Size H                 : 249.999900
Max Page Size Unit              : Millimeters
Font Name                       : Arial-ItalicMT, Arial-BoldItalicMT, ArialMT, Arial-BoldMT
Font Family                     : Arial, Arial, Arial, Arial
Font Face                       : Italic, Bold Italic, Regular, Bold
Font Type                       : Open Type, Open Type, Open Type, Open Type
Font Version                    : Version 5.21, Version 5.21, Version 5.21, Version 5.21
Font Composite                  : False, False, False, False
Font File Name                  : ariali.ttf, arialbi.ttf, arial.ttf, arialbd.ttf
Plate Names                     : Cyan, Magenta, Yellow, Black, Auto
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : Auto
Swatch Colorant Type            : SPOT
Swatch Colorant Tint            : 100.000000
Swatch Colorant Mode            : RGB
Swatch Colorant Red             : 0
Swatch Colorant Green           : 0
Swatch Colorant Blue            : 0
Page Count                      : 39
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QVXAMM240ED

Navigation menu