BARCO AMM260WTDS 26" LCD Color Display User Manual SV4 Rev03
Advan Int'l Corp. 26" LCD Color Display SV4 Rev03
BARCO >
Contents
- 1. User Manual
- 2. User Manual 1 of 2
- 3. User Manual 2 of 2
User Manual
Table of Contents English Warnings and Cautions ........................................................................ 2 Warnings ........................................................................................... 2 Cautions ............................................................................................ 3 Symbol Definitions ................................................................................ 5 Product Description and Intended Use ............................................... 6 Product Contents .............................................................................. 6 System Interconnection .................................................................... 8 Power Connection ............................................................................. 8 Operating the Monitor ........................................................................... 9 Front Panel Controls ......................................................................... 9 Standard On-Screen Display (OSD) Operation .............................. 10 Stryker Camera Preset Modes ........................................................ 10 OSD Function Description .............................................................. 11 Cleaning the Monitor ........................................................................... 12 Troubleshooting .................................................................................. 13 Technical Specifications ..................................................................... 14 Classification and Approvals ........................................................... 15 Electromagnetic Compatibility ........................................................... 16 Dimension Drawing .............................................................................. 21 Warranty ............................................................................................... 22 Service and Claims .............................................................................. 22 Declaration of Conformity .................................................................. 23 Warnings and Cautions Please read this manual and follow its instructions carefully. The words warning, caution, and note carry special meanings and should be carefully reviewed: Warning The personal safety of the patient or physician may be involved. Disregarding this information could result in injury to the patient or physician. Warning A lightning bolt within a triangle is intended to warn of the presence of hazardous voltage. Refer all service to authorized personnel. Caution Special service procedures or precautions must be followed to avoid damaging the instrument. Note Special information to make maintenance easier or important information more clear. Warnings Warning To avoid potential serious injury to the user and the patient, and/or damage to this device, the user must: 1. Restrict this device to use by, or on the order of, a physician, because of Federal law (United States of America). 2. Read the operating manual thoroughly and be familiar with its contents prior to using this equipment. 3. Carefully unpack the unit and check if any damage occurred during shipment. 4. Test this equipment prior to a surgical procedure. This monitor was fully tested at the factory before shipment. 5. Do not place the monitor or any other heavy object on the power cord. Damage to the cable can cause fire or electric shock. 6. Should any solid object or liquid fall into the panel, unplug the unit and have it checked by qualified personnel before operating it any further. 7. Unplug the unit if it is not to be used for an extended period of time. To disconnect the cord, pull it out by the plug. Never pull the cord itself. 8. To avoid electric shock, avoid removing control unit covers. English 9. Do not attempt internal repairs or adjustments not specifically detailed in this operating manual. 10. Pay close attention to the care and cleaning instructions in this manual. A deviation may cause damage (refer to the Cleaning section). 11. Do not sterilize the monitor. 12. Use appropriate caution to prevent contact with fluids, if the unit is being used with a power supply in patient environments. Cautions 1. The AC Adapter must be plugged into a grounded power outlet. 2. Use only the proprietary VISION ELECT HDTV(model 240-030960) power supply (P/N 240 -030-950, Manufacturer: JEC Korea, Model No: JMW1150KA2400F07) for the VISION ELECT HDTV (model 240-030-960) monitor. 3. Grounding reliability can only be achieved when the equipment is connected to an equipment receptacle labeled “Hospital Only” or “Hospital Grade.” 4. To connect to an international power supply, use an attachment plug appropriate for the power outlet. 5. Turn power off when unit is not in use. 6. Remove the power module and connection when transporting the unit. 7. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit. 8. Handle the monitor with care. Do not strike or scratch the screen. 9. Never operate the unit right after having been transported from a cold location directly to a warm location. 10. Do not expose the monitor to moisture or directly apply liquid cleaners directly to the screen. Spray the cleaning solution into a soft cloth and clean gently. 11. Allow adequate air circulation to prevent internal heat buildup. 12. Do not place the unit on surfaces (rugs, blankets, etc.) or near materials (curtains, draperies) that may block the ventilation slots. The monitor is cooled by natural convection and has no fan. 13. Do not install the unit near sunlight, excessive dust, mechanical vibration or shock. 14. The unit is designed for operation in a horizontal position. Do not operate the unit in a vertical position. 15. Keep the unit away from equipment that uses strong magnets (i.e., large loudspeakers). 16. Do not touch the patient with signal input or output connectors. Equipment with SIP/SOP connectors should either comply with IEC 60601-1 and/or IEC 60601-1-1 harmonized national standards or the combination should be evaluated. 17. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note This equipment has been tested and found to comply with the limit for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. There is no guarantee that interference will not occur in a particular installation, which can be determined by turning the equipment off and on. The user is encouraged to try to correct the interference by one or more of the following measures: • • • • Reorient or relocate the receiving device. Increase the separation distance between the equipment. Connect the equipment to an outlet on a circuit different from that to which the other device(s) are connected. Consult the manufacturer or field service technician for help. 18. To ensure electromagnetic compatibility, refer to the “Electromagnetic Compatibility” section of this manual. The VISION ELECT HDTV (model 240-030-960) monitor must be installed and operated according to the EMC information provided in this manual. The VISION ELECT HDTV (model 240-030-960) monitor has been tested under the UL 60601-1 standard and is UL listed for medical application. The warranty is void if any of these warnings or cautions are disregarded. Symbol Definitions English The following symbols appear on the product, its labeling, or the product packaging. Each symbol carries a special definition, as defined below Dangerous: High Voltage Consult accompanying documents. Direct Current Indicates protective earth ground. For indoor use only. DC power control switch SN Serial Number Top - Bottom Fragile Do not get wet Maximum Stacking Manufacturer European Authorized Representative Indicates proof of conformity to applicable European Economic Community Council directives and to harmonized standards published in the official journal of the European Communities. 51LJ Medical Equipment E215822 Medical Equipment is in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1 in regards to electric shock, fire hazards, and mechanical hazards. Tested to comply with FCC Class B standards. IPX1 Degrees of protection against the ingress of water. This symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment. DC power on at locker switch Product Description and Intended Use The VISION ELECT HDTV (model 240-030-960) High Definition LCD Monitor is an intelligent, microprocessor-based TFT-LCD monitor intended for use in endoscopic surgical applications. It has an ergonomically designed display and is compatible with most analog RGB (Red, Green, Blue) display standards. The VISION ELECT HDTV (model 240-030-960) monitor has the following features: • Advanced Viewing Solution (AVS): A sophisticated filter extends the viewing angle of the screen image, without sacrificing contrast ratio and brightness. • Upgraded video cards or software will not require buying a new monitor because of the wide auto-scanning compatibility range. • The internal microprocessor digitally controls auto-scanning, for horizontal scan frequencies between 31.47 KHz and 78.88 KHz, and vertical scan frequencies between 50.0 Hz and 85.1 Hz. In each frequency mode, the microprocessor-based circuitry allows the monitor to function at the precision of a fixed frequency. • The resident memory allows for storing factory default settings and also additional user adjustment parameters. • The maximum resolution achievable is WUXGA (1920 × 1200, 60Hz), best suited for Stryker cameras. • The monitor is compliant with the VESA-DPMS powermanagement standard. In order to save energy, the monitor must be connected to a system compliant with the standard. • The monitor is designed to mount an accessory (such as a camera or speaker) with a 2 lbs (max) load per hole. • The monitor is certified by UL International in accordance with medical standard UL 60601-1. It is also CE marked for sale in the European Community for integration or use with medical products. Product Contents 1. Carefully unpack the VISION ELECT HDTV (model 240-030-960) monitor. Save the original carton and associated packing material. They will be useful should you have to transport or ship the unit. 2. Check the monitor and its accessories for any damage that may have occurred during shipping. Immediately report any damage English to the shipping company. 3. Check the contents of the accessories package with the following list to make sure all components have been included. In addition to this manual, you should find: (a) 1 DVI cable (b) 1 VGA HDDB15 cable (c) 1 AC adapter (Stryker P/N 240-030-950, Manufacturer: JEC Korea, Model No: JMW1150KA2400F07) (d) 1 Hospital-grade AC power cord (e) 4 M4 x 10mm VESA screws (not shown) (f) 1 BNC cable (g) 1 S-Video cable (a) (d) (b) (c) (f) (g) System Interconnection VISION ELECT HDTV VISIONELECT (Model240-030-930) 240-030-960) (Model Video Input Signals Video Input Signals Signal Output: Signal Output : DVI DVI RGBHV RGBHV S-Video S-Video C-Video C-Video Video Peripheral Peripheral Video Fiber (Optional) eg: SDC SIDNE eg: SDC VIDEO PRINTER SIDNE DVD/VCR VIDEO PRINTER etc... DVD/VCR etc... Video Sources: Camera (1188 Series, Video Sources: Camera (1188 Series, 1088 Series, 988 Series) 1088 Series, 988 Series) Power Connection Hospital-grade power cord Power Supply Stryker P/N: 240-030-950 Manufacturer: JEC Korea Model No: JMW1150KA2400F07 VISION ELECT HDTV (Model 240-030-960) Operating the Monitor English Front Panel Controls Operate the monitor using the rotary control located on the front panel. A list of the monitor controls and their functions is provided below. Power LED Rotary Control Power Switch Figure 1: The VISION ELECT HDTV LCD Monitor front panel controls. 1. Power LED: Indicates menu current status. Displays green if monitor is powered on, blinks orange if monitor is in Standby mode. 2. Power Switch: Turns the power ON or OFF. 3. Rotary Control (Turn Right): With the on-screen display menu activated, increases the value of the selected parameter. With the on-screen display deactivated, activates the video source selection menu. 4. Rotary Control (Turn Left): With the on-screen display menu activated, decreases the value of the selected parameter. With the on-screen display deactivated, activates the video source selection menu. 5. Rotary Control Switch (Push): Accesses/selects on-screen display menu. 6. Rotary Control Switch (Push and Hold): Exits on-screen display menu. Standard On-Screen Display (OSD) Operation The monitor provides an on-screen display to help navigate through the various monitor-adjustment menus. 1. Press the Rotary Control to activate the on-screen display (OSD) menu. 2. Rotate the Rotary Control to move up or down through the menu. The parameter will be highlighted when selected. 3. Press the Rotary Control to enter the next level OSD. 4. Rotate the Rotary Control to increase or decrease the value of the selected parameter, or to make a selection on different options. 5. To exit the OSD menu screen from the second- or third-level OSD menu, select the Exit option. To completely exit the OSD, press and hold the rotary control. If no keys are pressed for a time period, the OSD automatically times out. 6. While the OSD menu is deactivated, rotate the Rotary Control to activate the input signal selection menu. The current input signal will be highlighted with a dot. Rotate the rotary control to select the preferred input signal. Stryker Camera Preset Modes 10 Camera Resolution (H x V) Horizontal Frequency (KHz) Vertical Frequency (Hz) 988 1024 x 768 49.09 59.90 988i 1024 x 768 41.25 50.00 1088/SDC Pro2 1024 x 768 50.03 60.00 1088i/SDC Pro2 1024 x 768 41.10 50.00 1088/1188/SDC HD 1280 x 1024 64.02 60.10 1088i/1188i/SDC HD 1280 x 1024 59.99 50.00 OSD Function Description Item English Function Description Range Specialty Color Temperature RGB adjustment is available only for Standard, Arth and Lap settings) Choose between color temperatures for Standard, Arth, Lap, PACS, or Norm Red Red balance -128-128 Green Green balance -128-128 Blue Blue balance -128-128 Gamma Gamma value 0.1-2.5 Brightness Increase or decrease the brightness 0-100 Contrast Increase or decrease the contrast 0-100 Phase* Increase or decrease the Phase level 0-100 Setting Chroma* Increase or decrease the Chroma level 0-100 Image Sharpness Set image sharpness 1-10 Video Sharpness* Increase or decrease the video sharpness 1-4 Image Effect Scale Mode Choose scale mode between Fill all, V-fill, H-fill, or one to one Mirror Enable or Disable mirror image Freeze Frame Enable or Disable freeze frame Zoom/Pan Enable zoom-in and pan function PIP/POP Enable PIP/POP (Picture In Picture/Picture On Picture) function PBP Enable PBP (Picture By Picture) function Advanced OSD position Control Control OSD Menu Position, Background, and Timeout Screen Control** Control and adjust Horizontal, Vertical, Frequency, Phase DPMS Choose DPMS (Display Power Management Signaling) Auto Source Select Adjust Auto Source Select between on and off Restore Factory Settings Set to factory default Key lock Set to Key lock mode Information User Name Entry Enter custom username display for boot-up display Serial Number Display monitor serial number Runtime Display current run time of monitor Input Format Display current input format Actual on-screen display values may vary with updated versions of the firmware and user setting. * Only available under S or C video input. ** Only available under VGA input. 11 Cleaning the Monitor No specific liquid or chemical is necessary for cleaning this VISION ELECT HDTV (model 240-030-960) LCD monitor. We suggest to clean the monitor with non-abrasive cloths and cleaning solutions used in hospitals to clean similar equipment. We recommend using 70% Isopropyl alcohol for the screen surface and warm water and a mild detergent for all other surfaces. Other acceptable cleaning agents are listed below: • 70% isopropyl alcohol • Cidex (2.4% glutaraldehyde solution) • 0.5% Chlorhexidine in 70% isopropyl alcohol To clean the screen, do not spray liquid cleaners directly on to the unit. Stand away from the monitor and spray cleaning solution onto a cloth. Without applying excessive pressure, clean the screen with the slightly dampened rag. 12 Troubleshooting English Before returning your LCD monitor for service, consult the troubleshooting list below Problem Current Status LED ON Remedy Using the OSD, adjust the brightness and contrast to maximum, or reset them to their default settings. Check the power switch. No Picture LED OFF LED Blinking Check if the AC power cord is properly connected to the AC adapter. Check if the video signal cable is properly connected at the back of the monitor. Check if the power to the computer system is ON. Abnormal Picture Oversized or undersized display; missing display; center shift Using the Auto Setup button, adjust CLOCK, CLOCK-PHASE, H-POSITION, and V-POSITION with non-standard signals. Wait for a few seconds after adjusting the size of the image before changing or disconnecting the signal or powering OFF the monitor. 13 Technical Specifications Display LCD Monitor Panel Synchronization Pixel Pitch Response Time View Angle Display Colors Native Resolution Input Signal Maximum Pixel Clock Electrical Power Adapter Power Consumption Current Dimensions (Free Stand) Dimensions (W × H × D) Weight VESA Mounting Interface Operating Conditions Operating Temperature Relative Humidity Atmospheric Pressure Range Electrical Input Rating Transport & Storage Conditions Storage Relative Humidity Range Atmospheric Pressure Range 14 25.54 inches (a-Si TFT Active matrix LCD) 2.5 - 5.0 Vpp separated sync 0.2865(W) x 0.2865(H) <25ms Typ +/-89° (L/R) × +/-89° (U/D) 16 million colors 1920 dots × 1200 dots 1 x DVI 1 x VGA 1 x SDI 1 x C-Video/SOG 1 x S-Video 1 x Component (Y/G, Pb/B, Pr/R, H/CS, VS) 1 x Optical 170MHz AC 100-240V; DC 24V 150 (max) Direct 616.4 x 428.8 x 121.2mm 19.62lbs VESA 100 x 100mm 41 to 90°F (5 to 32.2°C) 10 to 60% 500 to 1060 hPa 24V DC 6.25A -4 to 140°F (-20 to 60°C) 10 to 85% 500 to 1060 hPa Classification and Approvals English 51 LJ Medical Equipment E215822 Class I Equipment Medical equipment with respect to electric shock, fire and mechanical hazards only in accordance with UL 60601-1 and CAN/CSA C22.2 No. 601.1. IPX1 Water Ingress Protection Continuous operation Warning This equipment is not suitable for use in the presence of a FLAMMABLE ANESTHETIC MIXTURE WITH AIR, or WITH OXYGEN OR NITROUS OXIDE. This monitor is intended for use on Health Care Facilities model --. No user serviceable parts inside. Ask qualified personnel before accessing internal components. Caution For disposal of waste product, follow the requirement of the local code. This product is considered electronic equipment. It must not be disposed of as unsorted municipal waste, and must be collected separately. Please contact the manufacturer or other authorized disposal company to decommission your equipment. 15 Electromagnetic Compatibility Like other electrical medical equipment, the VISION ELECT HDTV (model 240-030-960) monitor requires special precautions to ensure electromagnetic compatibility with other electrical medical devices. To ensure electromagnetic compatibility (EMC), the VISION ELECT HDTV (model 240-030-960) monitor must be installed and operated according to the EMC information provided in this manual. Note The VISION ELECT HDTV (model 240-030-960) monitor has been designed and tested to comply with IEC 60601-1-2:2003 requirements for EMC with other devices. Caution The VISION ELECT HDTV (model 240-030-960) monitor may be interfered with by other equipment, including portable and mobile RF communication equipment, even if such equipment meets the applicable emissions requirements. Warning Do not use cables or accessories other than those provided with the VISION ELECT HDTV (model 240030-960) monitor, as this may result in increased electromagnetic emissions or decreased immunity to such emissions. Warning If the VISION ELECT HDTV (model 240-030-960) monitor is used adjacent to or stacked with other equipment, observe and verify normal operation of the VISION ELECT HDTV (model 240-030-960) monitor in the configuration in which it will be used prior to using it in a surgical procedure. Consult the tables below for guidance in placing the VISION ELECT HDTV (model 240-030-960) monitor Warning When this device is connected with other electrical equipment, leakage currents may be additive. To minimize total leakage current per patient, ensure that all systems are installed according to the requirements of IEC 60601-1-1. 16 English Manufacturer's declaration - electromagnetic emissions VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030960) monitor should assure that it is used in such an environment. Emissions test Compliance RF emissions CISPR11 Group 1 RF emissions CISPR11 Class B Harmonic emissions IEC61000-3-2 Class D Voltage Fluctuations/ flicker emissions IEC61000-3-3 Complies Electromagnetic Environment - guidance The VISION ELECT HDTV (model 240-030960) monitor must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be affected. VISION ELECT HDTV (model 240-030-960) monitor is suitable for use in all establishments, including domestic establishments and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. 17 Manufacturer's declaration - electromagnetic immunity VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030-960) monitor should assure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic environment guidance Electrostatic Discharge (ESD) IEC61000-4-2 6kV contact 8kV air 6kV contact 8kV air Floors should be wood, concrete, or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/ burst IEC61000-4-4 2kV for power supply lines 1kV for input/output lines 2kV for power supply lines 1kV for input/output lines Mains power quality should be that of a typical commercial or hospital environment. Surge IEC61000-4-5 1kV differential mode 2kV common mode 1kV differential mode 2kV common mode Mains power quality should be that of a typical commercial or hospital environment. 3.0 A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. <5% Ut (>95% dip in Ut) for 0.5 cycle 40% Ut (60% dip in Ut) for 5 cycles 70% Ut (30% dip in Ut) for 25 cycles <5% Ut (>95% dip in Ut) for 5 sec. Mains power quality should be that of a typical commercial or hospital environment. If the user of VISION ELECT HDTV (model 240-030-960) image intensifier requires continued operation during power mains interruptions, it is recommended that VISION ELECT HDTV (model 240030-960) image intensifier be powered from an uninterruptible power supply or a battery. Power frequency (50/60Hz) magnetic field IEC 61000-4-8 Voltage dips, short interruptions and voltage variations on power supply input lines IEC61000-4-11 3.0 A/m <5% Ut (>95% dip in Ut) for 0.5 cycle 40% Ut (60% dip in Ut) for 5 cycles 70% Ut (30% dip in Ut) for 25 cycles <5% Ut (>95% dip in Ut) for 5 sec. NOTE: Ut is the A.C. mains voltage prior to application of the test level. 18 Manufacturer's declaration - electromagnetic immunity English VISION ELECT HDTV (model 240-030-960) monitor is intended for use in the electromagnetic environment specified below. The customer or the user of VISION ELECT HDTV (model 240-030-960) monitor should ensure that it is used in such an environment. Immunity Test IEC 60601 Test Level Compliance Level Electromagnetic Environment: Guidance Portable and mobile RF communications equipment should be used no closer to any part of the VISION ELECT HDTV (model 240-030-960) monitor system, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 3 Vrms 150 kHz to 80 MHz 3V Radiated RF IEC 61000-4-3 3 V/m 80MHz to 2.5 GHz 3 V/m Recommended Separation Distance d = 1.17 P d = 1.17 P 80 MHz to 800 MHz d = 2.33 P 800 MHz to 2.5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey (a), should be less than the compliance level in each frequency range (b). Interference may occur in the vicinity of equipment marked with the following symbol: NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. (a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast, and TV broadcast, cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the VISION ELECT HDTV (model 240-030-960) monitor system is used exceeds the applicable RF compliance level above, the VISION ELECT HDTV (model 240-030-960) monitor system should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the VISION ELECT HDTV (model 240030-960) monitor unit. (b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 19 Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the VISION ELECT HDTV (model 240-030-960) monitor System The VISION ELECT HDTV (model 240-030-960) monitor system is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The user of the VISION ELECT HDTV (model 240-030-960) monitor system can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the VISION ELECT HDTV (model 240-030-960) monitor system as recommended below, according to the maximum output power of the communications equipment. Separation distance (m) according to frequency of transmitter Rated maximum output power (W) of transmitter 0.01 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2.5 GHz d = 1.17 P d = 1.17 P d = 2.33 P 0.12 0.12 0.23 0.1 0.37 0.37 0.74 1.17 1.17 2.33 10 3.70 3.70 7.37 100 11.70 11.70 23.30 For transmitters rated at a maximum output power not listed above, the recommended separation distance (d) in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people. 20 Dimension Drawing (mm) English 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2007:11:01 16:41:28-08:00 Author : ericlau Modify Date : 2007:11:09 16:55:14+09:00 XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Format : application/pdf Creator : ericlau Title : SV4_Rev03.fm Document ID : uuid:ad2a05d8-cbcb-40c5-8626-af3df3a02f7f Instance ID : uuid:fdc0d9c2-960e-40ac-b741-bd836354eaa1 Page Count : 21EXIF Metadata provided by EXIF.tools