BCF Technology ESGL01 Ultrasound Scanner User Manual Easi Scan manual French ver AW V 3 Mar 2016
BCF Technology Ltd Ultrasound Scanner Easi Scan manual French ver AW V 3 Mar 2016
Scan Go Manual full Eng Ver. LR AW V13 Dec 2017
TM Instruction manual Your animal imaging partner TM Contents Introduction Scanner menu LED sequence BCF Go Scan App Usage files 10 Factory reset 10 Measurements menu 13 Care & maintenance 17 Certification BCF Technology Ltd., hereby declares that the radio equipment type that we use on Easi-Scan:Go is in compliance with all CE Directives. The full text of the EU declaration of conformity is available at the following internet address: www.bcftechnology.co.uk This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. If the user changes any modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: All BCF Technology products are for animal applications only. TM 1 Scanner menu Power button • Up button • • Adjust gain. Save videos. • Down button • • • Adjust depth. Save images. To switch on/off the scanner press and hold until it beeps. If no viewing devices are connected, double press to change Wi-Fi channel. Short press to freeze the image. 1.1 Adjusting gain and depth using scanner´s buttons In live scanning pressing “Up” button will bring up the gain menu. Pressing “Down” button will bring up depth menu. Once the gain or depth is visible, pressing the “Power Button” will select that settings. Use The Up and Down buttons to adjust the selected settings. TM 1.2 Saving images and videos using scanner´s buttons Freeze the image using “Power button” Press “Up” will bring up “Save Cine”. Freeze the image using “Power button” Press “Down” will bring up “Save Image”. Once the desired option is visible, pressing the Power Button will select that option. Note: The scanner will store the last 300 frame (10-12.5 seconds depending on the selected scan depth) in its internal memory. To store on the scanner, the scanner must be Frozen. During save, particularly cine save, the app will pause while downloading and saving the data while scanning. It is recommended that you save images and videos directly from the app where possible. 2 LED sequence Power LED Blue flashing Scanner turning on Blue Scanner on and battery between 66–100% charge Yellow Scanner on and battery between 33–66% charge Yellow flashing Scanner on and battery between 0–33% charge Wireless LED Blue flashing Scanner ready for smart device to connect, nothing connected Blue Smart device connected Blue Scanner is charging when placed on wireless charging plate Both LEDs Power LED Wireless LED Flashing yellow Software updating TM 3 Activation 3.1 First time use Download the BCF Go Scan app from Google Play or the App store. To activate the scanner, ensure that the scanner is charged and that you have a local Wi-Fi internet connection. This is only necessary the first time you connect the scanner. 1. Press “Power button” to switch on the scanner. Open app on the smart device. The app will request to connect to the scanner. Click OK. 2. Select EASISCAN from the Wi-Fi page and return to the app. 3 App requests to connect to the internet. Click OK. The app will get serial number from the scanner. 4. Select your local Wi-Fi network to connect to the internet. 5. App requests to connect back to the scanner and retrieves the licence from BCF’s licence server. 6. Select your EASISCAN from the Wi-Fi page and return to the app. After a few seconds, the ultrasound image will appear. Touch anywhere on the screen to bring up the live scanning menu. Note – if the LED flashes on the scanner it is not connected to any smart device. 3.2 Normal start up process 1. Switch on the scanner and wait until the Wi-Fi LED illuminates. Launch BCF Go App. App requests to connect to scanner. 2. Select your EASISCAN from the Wi-Fi page. Return to the App. 3.It can take up to 10 seconds to connect and start receiving ultrasound. You are now ready to scan. TM 4 BCF Go Scan App 4.1 Live scanning Wi-Fi channel quality* (only on Android devices) Recording indicator and elapsed time during recording. No probe contact, scanner enters low-power mode and the screen will dim. The scanner battery level The smart device battery level *Change the channel in Wi-Fi settings. No indicator -clear channel in the 5GHz band. This is recommended state. White indicator-clear channel, but is on 2.4GHz band. It is more prone to interference. Orange/red indicator-channel with other networks or scanner. This is likely to cause interference issues. Touching the screen with two fingers simultaneously will freeze the image. Touching the scanner with one finger will open the main menu. TM 4.2 Main menu Start recording Adjust scanning depth Open Settings Freeze ultrasound Adjust gain 4.2.1 Freeze menu Unfreeze and return to live scanning. Callipers to measure size of the embryo Cattle Go to cine mode Save image on smart device Draw annotations on the image Sheep TM Callipers Save images to the camera folder on a smart device. Reset the cursors to the initial positon. Return to freeze menu. Note: Use your finger to move crosses. Cattle Crown rump length Head length Head diameter Trunk diameter Eye diameter TM Gestational measurements available: CrownRump length (distance from the top of the skull to the end of the body) Trunk diameter (width of the ribcage at the widest part) Eye diameter (diameter of the eye socket) Head diameter, (width of the skull at the widest point) Head length (distance from the top of the skull to the end of the nose) 14mm – 180mm, 33 – 76 days 14mm – 123mm, 53 – 133 days 3mm – 28mm, 62 – 241 days 14mm – 86mm, 55 - 135 days 21mm – 146mm, 56 – 134 days Sheep Gestational measurements available: Head diameter Trunk diameter (width of the skull at the widest point) (width of the ribcage at the widest part) 19mm – 66mm, 48 - 121 days 14mm – 101mm, 49 – 126 days Head diameter Trunk diameter TM Freedraw Touch and drag to draw on screen, can be used to make simple annotations or to highlight areas of interest. Any measurements placed on screen remain visible. Save button, save the current image to the camera folder. Reset button, deletes all drawn lines. Back button, return to freeze menu. Cine mode The app automatically stores the last 300 ultrasound frames (approximately 10 seconds), in cine mode. These frames can be viewed individually or as a video, individual frames can be saved as still images or the entire loop as in copy. Save image Save cine Back Frame forward Frame slider Play Frame back 10 TM 4.3 Settings Access the Terms and conditions, Quick Guide, FAQ Machine settings User settings Wi-Fi settings (only on Android devices) Note: FAQ and terms and conditions require an internet connection. 4.3.1 Machine settings Adjust screen brightness. Restores to original settings when the app is closed. Adjust ulttrasound contrast Select probe orientation. The probe orientation will change on all connected devices. Fit ultrasound by height or width. Lock screen rotation Adjust menu timeout Grid setting. The grid overlay will change on all connected devices. Invert the ultrasound image. Note: Touching outside the menu area will return to live scanning. 11 TM 4.3.2 User settings Number of usage files on this device, when it was synchronised with the server Software version of app User name User email Practice or company name Scanner serial number Licence expiry date Type of scanner Software version of scanner Wi-Fi settings Wi-Fi settings are only available on Android devices. Channels can be changed. 12 Software version of scanner Tap and select the channel. Yellow, orange, red are congested channels Green are clear channels 2.4 GHz channels Prone to interference 5GHz channels. Best connection TM 5 Usage files The app will generate usage files. Events logged: • Images saved – time and date, scanner serial number and location (if permitted) • Connecting to scanner • Freeze and unfreeze • Texts from Visits ToDo App • Entering and exiting standby mode Files can be uploaded to BCF’s license server, www.licencing.bcftechnology.com. • Automatically - if launching app when connected to WiFi • Manually – by clicking sync button • Prompts – If there are more than 20 usage files to upload 6 Factory reset A scanner can be reset to factory firmware settings in the unlikely event the scanner fails. Hold down power and down until both LED’s glow yellow and release. This will take a few minutes and the scanner will then switch off – removing the license from the scanner. 13 TM 7 Charging The battery can be charged in the charging dock, powered by a standard outlet. It can also be connected in the carry case for in-car charging. 3rd LED 2nd LED 1st LED A fully discharged battery should be fully charged within 5.5 hours. While in a good condition, the battery run time will be 5 hours (assuming 50% idle time between scans). Scanner will enter low power mode when idle. The Li-ion cells used in the battery pack do not suffer from the ‘Memory effect’. For optimal battery longevity, avoid letting the battery run completely down and recharge at approximately 20 Celsius/68 Fahrenheit. LED sequence One Blue flashing Charging, charge level below 33% First LED Blue solid Second LED flashing blue Charging, charge level below 66% First and second LEDs solid blue, third LED flashing blue Charging, charge level below 100% All LEDs solid blue – fully charged. Fully charged All LEDs flashing yellow Temperature is too high (more than 45 Celsius, 113 Fahrenheit) for safe charging All LEDs flashing blue Temperature is too low (less than 0 Celsius, 32 Fahrenheit) for safe charging. Electrical connection to the power pack is through the gold pads on battery and scanner. Power pack output is protected but care should be taken to prevent short circuiting the gold connector pins and pads. Warning: To reduce the risk of burns, fire, electric shock, or injury to persons an appliance should never be left unattended when plugged into mains or 12 V cigarette lighter. 14 TM 8 Care & maintenance 8.1 Easi-Scan: Go & battery Please note the following important points: • The unit is not sealed against jets of water. Water will penetrate your scanner if it is hosed down or rinsed under a fast flowing tap. • The unit is NOT corrosion proof and thus it should not be left wet.Take care to detach the external battery and ensure interconnect areas are dry also. • The battery charger and charging carry case are not waterproof – avoid getting them wet. 8.2 Easi-Scan: Go probe While every attempt has been made to make the probe as rugged as possible the crystal array remains vulnerable and should be protected from knocks. The probe has a protective sheath covering the length of cable subject to wear and flexing. Any damage to this sheath or the rest of the cable should be repaired before further use to prevent moisture ingress that will rapidly damage the probe. The probe should be checked regularly for such damage. Gels Use only gels recommended by BCF Technology Ltd. Do not store the probe in gel. Cleaning The probe may be cleaned by removing all residue and disinfecting using an IPA wipe. Storage Clean and dry the probe head prior to storage in dry location. Do not store the transducer in gels or cleaning/disinfecting solutions. This will lead to premature deterioration of the probe. Do not expose the transducer to materials containing the following agents: • Acetone • Methanol • Mineral oil • Iodine • Freon • Industrial cleaners • Materials containing perfumes (lotions, gels, etc.) 9. Specifications Warning: Never sterilize the transducer with autoclave, ultraviolet, gamma radiation, gas, steam or heat sterilization techniques. Severe damage will result. 15 TM Size 19x8.3x6.2cm / 7.5 x 3.25 x 2.4 in Weight 800g/1.76lbs Mechanical Rugged PC/ABS casing with TPE over mould User Output Scanner wireless link to compatible viewing device using BCF Sound-Link over standard WI-FI connection. Image and video storage Storage of images and cine loops limited only by available space on smart device linked with scanner. Probe Broadband straight linear rectal Active array length 64 mm Frequency range 4.5 to 8.5 MHz 3 user selectable depths of scan: 6cm, 8cm, 12cm 128 element crystal array 16 digital channels and 32 channel receiver Power and charging Removable li-ion battery gives 5h runtime * Battery charge time 5.5h. Only use BCF aproved/supplied 12V vehicle power supply, battery charger and DC power adapter. Maximum output voltage and current raiting of the charger is 4.2V and 2A. *depending on use, assuming 50% scan time, auto power save with BCF Smart-Beam. Temperature range Scanner: -10 Deg C to 45 Deg C *. Battery Charge: 0 Deg C to 35 Deg C * * Best charged at 25 Deg C, frequent chaging at 35 Deg C / 95 F may shorten battery lifetime. Battery Charger has under and over temperature protection and LED status indication. Warranty BCF Technology warrants Easi-Scan:Go against defects in materilas for one year from the date of purchase. BCF Technology does not warrant against normal wear and tear, nor damage caused by accident or abuse. Lifiteme warranty is available on request. Smart devices compatibility Android: Minimum version: Kit Kat (Android V4.4) Minimum RAM: 1.5Gb Minimum Processor: Quad-Core 1.2GHz Recommended WiFi: 802.11 a/ac (5GHz band) Apple: Minimum version: iOS 8 Minimum iPhone version: iPhone 5s Minimum iPad version: iPad4 16 TM For further information and video manuals about the Easi- Scan:Go please visit the “Customer support“ section of the BCF website www.bcftechnology.com/service-support 11 Service centres If your Easi-Scan requires servicing please contact official authorised service centres below or distributor in your country. Distributors contact details can be found at www.bcftechnology.com. In the UK: BCF Technology Ltd Imaging House, Phoenix Crescent Strathclyde Business Park Bellshill, ML4 3NJ Schottland, UK T +44 (0)1506 460 023 info@bcftechnology.com www.bcftechnology.com In Ireland: BCF Technology Ltd Unit 2, Quayside Business Park Mill Street, Dundalk Co Louth, Ireland T +353 (0)42 932 0070 ireland@bcftechnology.com www.bcftechnology.com In North America: BCF Technology USA Ltd, LLC 2625 Highway 14 West, Suite K Rochester, Minnesota 55901 T 507-529-8200 T 800-210-9665 F 507-529-8205 contact@bcftechnology.com www.bcftechnology.com In Australasia: BCF Ultrasound Australasia Pty Ltd 10/56 Norcal Road Nunawading 3131 Melbourne, Victoria Australia T +61 (0)3 9894 8980 service@bcfultrasound.com www.bcfultrasound.com Easi-Scan:Go does not contain user serviceable parts. Servicing has to be done by BCF´s authorised service centers. © BCF Technology Ltd, 2017 | Easi-Scan:GO
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42 Instance ID : uuid:021d76df-b189-8f4b-9591-30ef282b2c04 Original Document ID : adobe:docid:indd:caa2edec-e865-11dd-8244-f19c944c00c7 Document ID : xmp.id:02414238-846d-4607-8f66-21bb0896a1cc Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:08f0ebec-ef8a-47c4-84b1-bc7d343c5578 Derived From Document ID : xmp.did:09A782750B206811822AB25F6B84EF2B Derived From Original Document ID: adobe:docid:indd:caa2edec-e865-11dd-8244-f19c944c00c7 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Macintosh) History Changed : / History When : 2018:02:11 22:42:03Z Create Date : 2018:02:11 22:42:02Z Modify Date : 2018:02:11 22:42:11Z Metadata Date : 2018:02:11 22:42:11Z Rating : 5 Creator Tool : Adobe InDesign CC 2015 (Macintosh) Format : application/pdf Title : Easi-Scan manual French ver. AW V.3 Mar 2016 Creator : JL Cezon - Photodesign Studio Description : Easi-Scan manual French Subject : Easi-Scan manual, BCF technology, Jose Luis Cezon, photodesign Studio, www.photodesign-studio.com, photodesign Studio, mail to photodesign.studio@hotmail.com Rights : ©JL Cezon ©Photodesign Studio Web Statement : www.photodesign-studio.com Authors Position : Easi-Scan manual Producer : Adobe PDF Library 15.0 Trapped : False Creator Work Email : photodesign.studio@hotmail.com. Creator Work URL : www.photodesign-studio.com Page Count : 17 Author : JL Cezon - Photodesign StudioEXIF Metadata provided by EXIF.tools