BCF Technology ESGL01 Ultrasound Scanner User Manual Easi Scan manual French ver AW V 3 Mar 2016

BCF Technology Ltd Ultrasound Scanner Easi Scan manual French ver AW V 3 Mar 2016

Scan Go Manual full Eng Ver. LR AW V13 Dec 2017

Download: BCF Technology ESGL01 Ultrasound Scanner User Manual Easi Scan manual French ver  AW V 3 Mar 2016
Mirror Download [FCC.gov]BCF Technology ESGL01 Ultrasound Scanner User Manual Easi Scan manual French ver  AW V 3 Mar 2016
Document ID3778057
Application IDBVXO/TL+J1+sE1Xk/aMH7g==
Document DescriptionScan Go Manual full Eng Ver. LR AW V13 Dec 2017
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.22kB (340305 bits)
Date Submitted2018-03-13 00:00:00
Date Available2018-09-10 00:00:00
Creation Date2018-02-11 22:42:02
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-02-11 22:42:11
Document TitleEasi-Scan manual French ver. AW V.3 Mar 2016
Document CreatorAdobe InDesign CC 2015 (Macintosh)
Document Author: JL Cezon - Photodesign Studio

TM
Instruction manual
Your animal imaging partner
TM
Contents
Introduction			
Scanner menu		
LED sequence		
BCF Go Scan App
Usage files		
10
Factory reset			
10
Measurements menu
13
Care & maintenance
17
Certification
BCF Technology Ltd., hereby declares that the radio equipment type that we use on Easi-Scan:Go
is in compliance with all CE Directives. The full text of the EU declaration of conformity is
available at the following internet address: www.bcftechnology.co.uk
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
If the user changes any modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Note: All BCF Technology products are for animal applications only.
TM
1 Scanner menu
Power button
•
Up button
•
•
Adjust gain.
Save videos.
•
Down button
•
•
•
Adjust depth.
Save images.
To switch on/off the
scanner press and hold
until it beeps.
If no viewing devices are
connected, double press
to change Wi-Fi channel.
Short press to freeze the
image.
1.1 Adjusting gain and depth using scanner´s buttons
In live scanning pressing “Up” button will bring
up the gain menu.
Pressing “Down” button will bring up depth
menu.
Once the gain or depth is visible, pressing the “Power Button” will select that settings. Use The
Up and Down buttons to adjust the selected settings.
TM
1.2 Saving images and videos using scanner´s buttons
Freeze the image using “Power button”
Press “Up” will bring up “Save Cine”.
Freeze the image using “Power button”
Press “Down” will bring up “Save Image”.
Once the desired option is visible, pressing the Power Button will select that option.
Note: The scanner will store the last 300 frame (10-12.5 seconds depending on the selected scan
depth) in its internal memory. To store on the scanner, the scanner must be Frozen. During save,
particularly cine save, the app will pause while downloading and saving the data while scanning.
It is recommended that you save images and videos directly from the app where possible.
2 LED sequence
Power LED
Blue
flashing
Scanner turning on
Blue
Scanner on and battery
between 66–100% charge
Yellow
Scanner on and battery
between 33–66% charge
Yellow
flashing
Scanner on and battery
between 0–33% charge
Wireless LED
Blue
flashing
Scanner ready for smart
device to connect, nothing
connected
Blue
Smart device connected
Blue
Scanner is charging
when placed on wireless
charging plate
Both LEDs
Power
LED
Wireless
LED
Flashing
yellow
Software updating
TM
3 Activation
3.1 First time use
Download the BCF Go Scan app
from Google Play or the App store.
To activate the scanner, ensure that the scanner is charged and that you have a local Wi-Fi
internet connection. This is only necessary the first time you connect the scanner.
1. Press “Power
button” to
switch on the
scanner. Open
app on the smart
device. The app
will request to
connect to the
scanner. Click
OK.
2. Select
EASISCAN
from the Wi-Fi
page and
return to the
app.
3 App requests
to connect to
the internet.
Click OK.
The app will
get serial
number from
the scanner.
4. Select your
local Wi-Fi
network to
connect to the
internet.
5. App requests
to connect back
to the scanner
and retrieves
the licence
from BCF’s
licence server.
6. Select your
EASISCAN from
the Wi-Fi page and
return to the app.
After a few seconds, the ultrasound image will appear. Touch anywhere on the screen to bring up
the live scanning menu.
Note – if the LED flashes on the scanner it is not connected to any smart device.
3.2 Normal start up process
1. Switch on the
scanner and wait
until the Wi-Fi
LED illuminates.
Launch BCF Go
App. App requests
to connect to
scanner.
2. Select your
EASISCAN
from the Wi-Fi
page. Return
to the App.
3.It can take up
to 10 seconds
to connect and
start receiving
ultrasound. You
are now ready
to scan.
TM
4 BCF Go Scan App
4.1 Live scanning
Wi-Fi channel quality*
(only on Android devices)
Recording
indicator
and elapsed
time during
recording.
No probe contact,
scanner enters
low-power
mode and the
screen will dim.
The scanner battery
level
The smart device
battery level
*Change the channel in Wi-Fi settings. No indicator -clear channel in the 5GHz band. This is
recommended state. White indicator-clear channel, but is on 2.4GHz band. It is more prone to
interference. Orange/red indicator-channel with other networks or scanner. This is likely to cause
interference issues.
Touching the screen with two fingers
simultaneously will freeze the image.
Touching the scanner with one finger will open
the main menu.
TM
4.2 Main menu
Start recording
Adjust
scanning depth
Open Settings
Freeze ultrasound
Adjust gain
4.2.1 Freeze menu
Unfreeze and return
to live scanning.
Callipers to measure
size of the embryo
Cattle
Go to cine mode
Save image on
smart device
Draw annotations on
the image
Sheep
TM
Callipers
Save images to the
camera folder on a
smart device.
Reset the cursors to
the initial positon.
Return to freeze
menu.
Note: Use your finger to move crosses.
Cattle
Crown rump length
Head length
Head diameter
Trunk diameter
Eye diameter
TM
Gestational measurements available:
CrownRump length
(distance from
the top of the
skull to the end
of the body)
Trunk diameter
(width of the
ribcage at the
widest part)
Eye diameter
(diameter of
the eye socket)
Head diameter,
(width of the
skull at the
widest point)
Head length
(distance from
the top of the
skull to the end
of the nose)
14mm – 180mm,
33 – 76 days
14mm – 123mm,
53 – 133 days
3mm – 28mm,
62 – 241 days
14mm – 86mm,
55 - 135 days
21mm – 146mm,
56 – 134 days
Sheep
Gestational measurements available:
Head diameter
Trunk diameter
(width of the skull at the widest point)
(width of the ribcage at the widest part)
19mm – 66mm, 48 - 121 days
14mm – 101mm, 49 – 126 days
Head diameter
Trunk diameter
TM
Freedraw
Touch and drag to draw on screen, can be used to make simple annotations or to highlight areas
of interest. Any measurements placed on screen remain visible.
Save button, save the
current image to the
camera folder.
Reset button, deletes all
drawn lines.
Back button, return to
freeze menu.
Cine mode
The app automatically stores the last 300 ultrasound frames (approximately 10 seconds), in cine
mode. These frames can be viewed individually or as a video, individual frames can be saved as
still images or the entire loop as in copy.
Save image
Save cine
Back
Frame forward
Frame slider
Play
Frame back
10
TM
4.3 Settings
Access the Terms
and conditions, Quick
Guide, FAQ
Machine
settings
User
settings
Wi-Fi settings
(only on Android
devices)
Note: FAQ and terms and conditions require an internet connection.
4.3.1 Machine settings
Adjust screen
brightness. Restores
to original settings
when the app is
closed.
Adjust ulttrasound
contrast
Select probe
orientation. The
probe orientation
will change on all
connected devices.
Fit ultrasound by
height or width.
Lock screen rotation
Adjust menu timeout
Grid setting. The grid
overlay will change
on all connected
devices.
Invert the ultrasound
image.
Note: Touching outside the menu area will return to live scanning.
11
TM
4.3.2 User settings
Number of usage
files on this device,
when it was
synchronised with
the server
Software version
of app
User name
User email
Practice or company
name
Scanner serial number
Licence expiry date
Type of scanner
Software version of
scanner
Wi-Fi settings
Wi-Fi settings are only available on Android devices. Channels can be changed.
12
Software version
of scanner
Tap and select the channel.
Yellow, orange, red are
congested channels
Green are clear channels
2.4 GHz channels
Prone to interference
5GHz channels. Best
connection
TM
5 Usage files
The app will generate usage files.
Events logged:
•
Images saved – time and date, scanner serial number and location (if permitted)
•
Connecting to scanner
•
Freeze and unfreeze
•
Texts from Visits ToDo App
•
Entering and exiting standby mode
Files can be uploaded to BCF’s license server, www.licencing.bcftechnology.com.
•
Automatically - if launching app when connected to WiFi
•
Manually – by clicking sync button
•
Prompts – If there are more than 20 usage files to upload
6 Factory reset
A scanner can be reset to factory firmware settings in the unlikely event the scanner fails.
Hold down power and down until both LED’s glow yellow and release.
This will take a few minutes and the scanner will then switch off – removing the license from the
scanner.
13
TM
7 Charging
The battery can be charged in the charging dock, powered by a standard outlet. It can also be
connected in the carry case for in-car charging.
3rd LED
2nd LED
1st LED
A fully discharged battery should be fully
charged within 5.5 hours. While in a good
condition, the battery run time will be 5
hours (assuming 50% idle time between
scans).
Scanner will enter low power mode when
idle.
The Li-ion cells used in the battery pack
do not suffer from the ‘Memory effect’. For
optimal battery longevity, avoid letting the
battery run completely down and recharge at
approximately 20 Celsius/68 Fahrenheit.
LED sequence
One Blue
flashing
Charging, charge level below
33%
First LED Blue
solid
Second LED
flashing blue
Charging, charge level below
66%
First and second
LEDs solid
blue, third LED
flashing blue
Charging, charge level below
100%
All LEDs solid
blue – fully
charged.
Fully charged
All LEDs flashing
yellow
Temperature is too high
(more than 45 Celsius, 113
Fahrenheit) for safe charging
All LEDs flashing
blue
Temperature is too low (less
than 0 Celsius, 32 Fahrenheit)
for safe charging.
Electrical connection to the power pack is through the gold pads on battery and scanner. Power
pack output is protected but care should be taken to prevent short circuiting the gold connector
pins and pads.
Warning:
To reduce the risk of burns, fire, electric shock, or injury to persons
an appliance should never be left unattended when plugged into
mains or 12 V cigarette lighter.
14
TM
8 Care & maintenance
8.1 Easi-Scan: Go & battery
Please note the following important points:
•
The unit is not sealed against jets of water. Water will penetrate your scanner if it is hosed
down or rinsed under a fast flowing tap.
•
The unit is NOT corrosion proof and thus it should not be left wet.Take care to detach the
external battery and ensure interconnect areas are dry also.
•
The battery charger and charging carry case are not waterproof – avoid getting them wet.
8.2 Easi-Scan: Go probe
While every attempt has been made to make the probe as rugged as possible the crystal array
remains vulnerable and should be protected from knocks. The probe has a protective sheath
covering the length of cable subject to wear and flexing. Any damage to this sheath or the rest
of the cable should be repaired before further use to prevent moisture ingress that will rapidly
damage the probe. The probe should be checked regularly for such damage.
Gels
Use only gels recommended by BCF Technology Ltd. Do not store the probe in gel.
Cleaning
The probe may be cleaned by removing all residue and disinfecting using an IPA wipe.
Storage
Clean and dry the probe head prior to storage in dry location. Do not store the transducer in gels
or cleaning/disinfecting solutions. This will lead to premature deterioration of the probe.
Do not expose the transducer to materials containing the following agents:
•
Acetone
•
Methanol
•
Mineral oil
•
Iodine
•
Freon
•
Industrial cleaners
•
Materials containing perfumes (lotions, gels, etc.)
9. Specifications
Warning:
Never sterilize the transducer with autoclave, ultraviolet, gamma
radiation, gas, steam or heat sterilization techniques. Severe
damage will result.
15
TM
Size				 		19x8.3x6.2cm / 7.5 x 3.25 x 2.4 in
Weight					800g/1.76lbs
Mechanical 			 Rugged PC/ABS casing with TPE over mould
User Output
Scanner wireless link to compatible viewing device using BCF Sound-Link over standard WI-FI
connection.
Image and video storage
Storage of images and cine loops limited only by available space on smart device linked with
scanner.
Probe
Broadband straight linear rectal
Active array length 64 mm
Frequency range 4.5 to 8.5 MHz
3 user selectable depths of scan: 6cm, 8cm, 12cm
128 element crystal array
16 digital channels and 32 channel receiver
Power and charging
Removable li-ion battery gives 5h runtime *
Battery charge time 5.5h. Only use BCF aproved/supplied 12V vehicle power supply, battery
charger and DC power adapter.
Maximum output voltage and current raiting of the charger is 4.2V and 2A.
*depending on use, assuming 50% scan time, auto power save with BCF Smart-Beam.
Temperature range
Scanner: -10 Deg C to 45 Deg C *.
Battery Charge: 0 Deg C to 35 Deg C *
* Best charged at 25 Deg C, frequent chaging at 35 Deg C / 95 F may shorten battery lifetime.
Battery Charger has under and over temperature protection and LED status indication.
Warranty
BCF Technology warrants Easi-Scan:Go against defects in materilas for one year from the date
of purchase. BCF Technology does not warrant against normal wear and tear, nor damage
caused by accident or abuse. Lifiteme warranty is available on request.
Smart devices compatibility
Android:
Minimum version: Kit Kat (Android V4.4)
Minimum RAM: 1.5Gb
Minimum Processor: Quad-Core 1.2GHz
Recommended WiFi: 802.11 a/ac (5GHz band)
Apple:
Minimum version: iOS 8
Minimum iPhone version: iPhone 5s
Minimum iPad version: iPad4
16
TM
For further information and video manuals about the Easi- Scan:Go please visit the “Customer
support“ section of the BCF website www.bcftechnology.com/service-support
11 Service centres
If your Easi-Scan requires servicing please contact official authorised service centres below or
distributor in your country. Distributors contact details can be found at www.bcftechnology.com.
In the UK:
BCF Technology Ltd
Imaging House, Phoenix Crescent
Strathclyde Business Park Bellshill,
ML4 3NJ
Schottland, UK
T +44 (0)1506 460 023
info@bcftechnology.com
www.bcftechnology.com
In Ireland:
BCF Technology Ltd
Unit 2, Quayside Business Park
Mill Street, Dundalk
Co Louth, Ireland
T +353 (0)42 932 0070
ireland@bcftechnology.com
www.bcftechnology.com
In North America:
BCF Technology USA Ltd, LLC
2625 Highway 14 West, Suite K
Rochester, Minnesota 55901
T 507-529-8200
T 800-210-9665
F 507-529-8205
contact@bcftechnology.com
www.bcftechnology.com
In Australasia:
BCF Ultrasound Australasia Pty Ltd
10/56 Norcal Road
Nunawading 3131
Melbourne, Victoria
Australia
T +61 (0)3 9894 8980
service@bcfultrasound.com
www.bcfultrasound.com
Easi-Scan:Go does not contain user serviceable parts. Servicing has to be done by BCF´s
authorised service centers.
© BCF Technology Ltd, 2017 | Easi-Scan:GO

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c067 79.157747, 2015/03/30-23:40:42
Instance ID                     : uuid:021d76df-b189-8f4b-9591-30ef282b2c04
Original Document ID            : adobe:docid:indd:caa2edec-e865-11dd-8244-f19c944c00c7
Document ID                     : xmp.id:02414238-846d-4607-8f66-21bb0896a1cc
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:08f0ebec-ef8a-47c4-84b1-bc7d343c5578
Derived From Document ID        : xmp.did:09A782750B206811822AB25F6B84EF2B
Derived From Original Document ID: adobe:docid:indd:caa2edec-e865-11dd-8244-f19c944c00c7
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Macintosh)
History Changed                 : /
History When                    : 2018:02:11 22:42:03Z
Create Date                     : 2018:02:11 22:42:02Z
Modify Date                     : 2018:02:11 22:42:11Z
Metadata Date                   : 2018:02:11 22:42:11Z
Rating                          : 5
Creator Tool                    : Adobe InDesign CC 2015 (Macintosh)
Format                          : application/pdf
Title                           : Easi-Scan manual French ver. AW V.3 Mar 2016
Creator                         : JL Cezon - Photodesign Studio
Description                     : Easi-Scan manual French
Subject                         : Easi-Scan manual, BCF technology, Jose Luis Cezon, photodesign Studio, www.photodesign-studio.com, photodesign Studio, mail to photodesign.studio@hotmail.com
Rights                          : ©JL Cezon ©Photodesign Studio
Web Statement                   : www.photodesign-studio.com
Authors Position                : Easi-Scan manual
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Creator Work Email              : photodesign.studio@hotmail.com.
Creator Work URL                : www.photodesign-studio.com
Page Count                      : 17
Author                          : JL Cezon - Photodesign Studio
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AL6R-ESGL01

Navigation menu