BEA 75.0151.05 Remote Control 20060903 Reference Guide Universal

User Manual: BEA Reference Guide - BEA Universal Remote Reference Guide

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadBEA - 75.0151.05 Remote Control 20060903 Reference Guide Universal
Open PDF In BrowserView PDF
BEA INC. UNIVERSAL REMOTE CONTROL REFERENCE GUIDE
FUNCTION

?

EAGLE

BODYGUARD
NOT USED

LOCK

LOCK

UNLOCK

UNLOCK

NOT USED

INQUIRY

INQUIRY

INQUIRY

SENSITIVITY
(0 – 9 max) Default = 8

SENSITIVITY
(0 – 9 max) Default = 8 closed, 8 open

SENSITIVITY
(0 – 9 max) Default = 8 closed, 7 open

HOLD TIME (0-9)
(0.5 sec – 9 sec)
Default = 0 (.5 sec)
RELAY OUTPUT (1-4)

HOLD TIME (0-9)
(1 - 10 sec)
Default = 0 (1 sec)
RELAY OUTPUT (1-4)

HOLD TIME (0-9)
(1 sec – 10 sec)
Default = 0 (1 sec)
RELAY OUTPUT (1-4)

1.
2.
3.
4.

1.
2.
3.
4.

1.
2.
3.
4.

Active output*
Passive output**
ON
OFF

Default = 1 (Active)

Using The Remote Control

Active output*
Passive output**
ON
OFF

Default = 1 (Active)

DETECTION MODE (1-3)
1
2
3

Bidirectional
Unidirectional
Unidirectional with MTF

Default = 3 (Uni-Directional
With MTF)

IMMUNITY (1-3)
1.
Extreme sensitivity
2.
Normal sensitivity
3.
Decreased sensitivity
NOT USED

RESTORE DEFAULT
SETTINGS (1)

0
1
2
3
4

30 sec
1 min
2 min
3 min
5 min

5
6
7
8
9

AUTO LEARN TIME (0-9)
7 min
10 min
15 min
20 min
25 min

PATTERN WIDTH (1-9)
1

Passive output**
Active output*
ON
OFF

Default = (Active)

AUTO LEARN TIME (0-9)
NOT USED

75.0151 V5 July 2003

DK-12

0
1
2
3
4

30 sec
1 min
2 min
3 min
5 min

5
6
7
8
9

7 min
10 min
15 min
20 min
25 min

PATTERN WIDTH (1-6)

Wide (Default – door closed)

1

2
Middle (Default – door open)
3
Asymmetrical Left Narrow
4
Asymmetrical Right Narrow
5
Narrow Left
6
Narrow Right
7
Asymmetrical Left Wide
8
Asymmetrical Right Wide
9
Center Narrow
Default = 1 (Wide/Middle)
PATTERN DEPTH (1-3)
1.
Deep pattern
2.
Medium pattern
3.
Limited pattern
Default = 1 door closed, 1 door open
FREQUENCY (1-2)
1.
Normal frequency
2.
Random frequency 1
3.
Random frequency 2
SET-UP (1-3) – See manual
1.
Door closed
2.
Door open
3.
Restore factory defaults

2
3
4
5
6

Wide (Default – door open &
closed)
Left Wide
Right Wide
Left Narrow
Center Narrow
Right Narrow
Default = 1 (Wide)

NOT USED

FREQUENCY (1-2)
1.
High impulse
2.
Low impulse
SET-UP (1-3) – See manual
1.
Door closed
2.
Door open
3.
Restore factory defaults

*Passive output (Fail-Safe): NO-COM circuit is closed and NC-COM circuit is open
** Active output (Fail-Secure): NC-COM circuit is closed and NO-COM circuit is open.

1. Every programming session with the remote
control MUST begin by unlocking the sensor
(except for DK-12). Press the UNLOCK key
once, and the sensor will unlock, unless there
has been a passcode previously stored. If so,
press UNLOCK once, then enter the code. If
code is unknown, power the sensor OFF, then
power back ON. Press UNLOCK with 60
seconds, then re-lock with the new code when
programming is complete. The default code is
0000 and is not required to be entered.
2. To INQUIRE a setting, simply UNLOCK the
sensor, then press the desired function key,
followed by the “?” key. Observe the LED on
the sensor and count the number of flashes to
determine current setting.
3. When programming is complete, press the
LOCK key twice. If a passcode is desired,
press the LOCK key once, followed by a 4digit code.
4. If there are several sensors in close proximity
to one another, be sure to exercise caution
when programming, as to not unlock more
than one sensor at a time.

BEA INC. UNIVERSAL REMOTE CONTROL REFERENCE GUIDE
Defaults shown in bold print if not not stated.
FUNCTION

?

IS-87/ IS-87XL

FALCON

WIZARD

LOCK

LOCK

LOCK

UNLOCK

UNLOCK

UNLOCK

INQUIRY

INQUIRY

INQUIRY

SENSITIVITY
(0 min – 9 max)
Default = 7

SENSITIVITY
(0 min – 9 max)
Default = 7

SENSITIVITY
(0 min – 9 max)
Default = 7

HOLD TIME (0-9)
(0.5 sec – 9 sec)
Default = 0 (0.5sec)
RELAY OUTPUT (1-4)

HOLD TIME (0-9)
(0.5 sec – 9 sec)
Default = 0 (0.5sec)
RELAY OUTPUT (1-4)

HOLD TIME (0-9)
(0.5 sec – 9 sec)
Default = 0 (0.5sec)
RELAY OUTPUT (1-4)

1.
2.
3.
4.

Active output*
Passive output**
ON
OFF

1.
2.
3.
4.

Active Output*
Passive Output**
ON
OFF

Default = 1 (Active)

Default = 1 (Active)

NOT USED

NOT USED

DETECTION MODE (1-3)
1.
2.
3.

Bidirectional
Unidirectional approach
Unidirectional depart

Default = 2 (Unidirectional
Approach)

DETECTION MODE (1-3)
1.
2.
3.

Bidirectional
Unidirectional approach
Unidirectional depart

1.
2.
3.

Active Relay / Passive Transistor
Passive Relay / Active Transistor
Passive Relay / Passive
Transistor
4.
Active Relay / Active
Transistor
5.
All Relay Output – Active
6.
All Relay Output – Passive
(5 & 6 on SN 52000 and higher only)
0 = 30 Sec
5 = 15 Minutes
1 = 1 Minute
6 = 20 Minutes
2 = 2 Minutes
9 = Infinity
3 = 5 Minutes
(9 is on SN 60000
4 = 10 Minutes
and higher only)

DETECTION MODE (1-3)
1.
2.
3.

Bidirectional
Unidirectional
Unidirectional With MTF

Default = 2 (Unidirectional Approach)

Default = 3 (Unidirectional with MTF)

TYPE OF DETECTION (1-2)
1.
Pedestrian & Vehicle
2.
Pedestrian only
IS-87 Default = 2 (Ped. Only)
IS-87XL = 1 (Ped. And vehicle)

REJECTION MODE (1-5)
1. Detects all traffic :pedestrian & vehicle
2. Detects all traffic + interference immunity
3. Low Pedestrian / Parallel traffic rejectiion
4. Mid Pedestrian / Parallel traffic rejectiion
5. High Pedestrian / Parallel traffic rejectiion

IMMUNITY (1-3) (MOTION)
1.
Extreme sensitivity
2.
Normal sensitivity
3.
Decreased sensitivity

NOT USED

NOT USED

RESTORE DEFAULT SETTINGS (1)

RESTORE DEFAULT SETTINGS (1)

INFRARED SENSITIVITY (1-2)
1.
Low gloss (high sensitivity)
2.
High gloss (lNormal
sensitivity)
SET-UP (0-2) – see manual
0. Infrared – Learn Background
1. Normal mounting height (7-10’)
2. Higher mounting height (10-12’)

*Passive output (Fail-Safe): NO-COM circuit is closed and NC-COM circuit is open
** Active output (Fail-Secure): NC-COM circuit is closed and NO-COM circuit is open.

75.0151 V5 July 2003



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 2
Title                           : Microsoft Word - 75.0151.05 Remote Control 20060903.doc
Producer                        : Mac OS X 10.9.2 Quartz PDFContext
Creator                         : Word
Create Date                     : 2014:05:02 18:33:03Z
Modify Date                     : 2014:05:02 18:33:03Z
EXIF Metadata provided by EXIF.tools

Navigation menu