BTI Wireless 1900-160 High Power Multi.Carrier Power Amplifier User Manual

Bravo Tech (Shenzhen) Co. Ltd. High Power Multi.Carrier Power Amplifier Users Manual

Users Manual

Download: BTI Wireless 1900-160 High Power Multi.Carrier Power Amplifier User Manual
Mirror Download [FCC.gov]BTI Wireless 1900-160 High Power Multi.Carrier Power Amplifier User Manual
Document ID1141028
Application IDyr9LraZ6/GQGODWPl2EtFA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize17.57kB (219603 bits)
Date Submitted2009-07-20 00:00:00
Date Available2009-07-21 00:00:00
Creation Date2009-07-20 17:59:18
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-07-20 17:59:46
Document TitleMicrosoft Word - LPA1900-160-SC01 operation introduction.doc
Document CreatorPScript5.dll Version 5.2
Document Author: D1CFC0F6

Product Operation Introduction
LPA1900-160-SC01
V1.0
2009-07-06
Bravo Tech Inc.
All right reserved
Version
V1.00
Revision
description
First edition
HISTORY
Prepared by
Xiao Hua Gan
Audited by
Cong HaiBao
Approved by
Content
Part A, Summary......................................................................... 4
Part B, Connector and definition................................................ 4
Part C, LED Indication ................................................................ 6
Part D, Specifications .................................................................. 6
Part E, Declare ................................................................................ 7
Part F, Information to the User ........................................................ 8
Accessory, Sample of Test Procedure ...................................... 8
1、Test equipment set up ............................................................. 8
1). Signal generator:............................................................................ 8
2). Spectrum analyzer: ........................................................................ 8
3). Power meter: ................................................................................. 9
4). Network analyzer ........................................................................... 9
2、 test condition description ........................................................ 9
1). Power supply cables and connectors: ......................................... 9
3、 Checking item before testing ................................................. 9
4、RF performance test procedure:............................................ 10
1) Spectrum emission ....................................................................... 10
2) Gain flatness................................................................................. 12
3) Gain Variation & Detect Accuracy & Current consumption
............................................................................................................13
Part A,
Summary
Bravo Tech Inc’s newly introduced High Power Multi-Carrier Power Amplifier platform provides
higher downlink EIRP to extend the coverage of existing networks. This multi-carrier based product
platform can also work with customized BTS to extend capacity of original BTS with a low system
total cost. This product platform features:
•
•
•
•
•
•
•
•
•
•
Available for UMTS band
Support multi-carrier WCDMA signals, with mixed mode operation
Output maximum power 160W, support carriers number up to 4.
Very High System Efficiency
Extensive product monitoring and control (local and remote)
Centralized system control/display/alarms
Great system reliability supported by architecture built-in redundancy
Powered by 30VDCavailable
Extensive protection for lightning, voltage surge, and any high failure rate assemblies
Compact system size and light weight
Part B,
Connector and definition
Block Diagram of MCPA in system
1、 RF Part
Port Name
Type
Warning
Input
SMA Female (50Ω)
Output
N Female (50Ω)
Normal :-6.2dBm
Maximum input power +1dBm.
Normal :52dBm
Maximum output power 52.5dBm.
2、 DC power
Port Name
DC IN
Type
NO
D-Sub type
DSCD175PS1M
(Male)
A1、A2
VDC type +30V, range 24~32V
A3、A4
GND to VDC
3、 Communication
Connector type: USB
Note: Manufacture use to debug.
Warning
Part C,
LED Indication
Figure 1 Power Amplifier Indicators
Table 1 Specification of Power Amplifier Indicator Lights
Item
Label
Color
State
MAJOR ALM
Red
On
MINOR ALM
Yellow
Off
RF ON
Green
Off
MAJOR ALM
Red
Off
MINOR ALM
Yellow
On
RF ON
Green
Off
MAJOR ALM
Red
Off
MINOR ALM
Yellow
Off
RF ON
Green
On
Part D,
Specification
Power amplifier alarms and
shuts down
Power amplifier alarms but still works
Power amplifier works normally
Specifications
1、 Electrical Specifications
PARAMETER
Frequency
SPECIFICATION
1930 ~ 1990 MHz (Band: any 15MHz@customer require,
maximal band Δ60MHz)
Output Power
Spurious Emission
(3G 4Carriers)
160Watts average max. (3FA, PAR:8.0dB), Any location in the BW.
@+29~ +31 Vdc
<-48dBc @±5MHz
<-50dBc @±10MHz
@-20℃~+50℃,Po=52dBm(max)
<-48dBc @±5MHz
@+29 ~ +31 Vdc
<-53dBc @±10MHz
RF Gain
@+25℃, Po=52dBm(max)
Normal Operating Voltage
57.0 ± 1.0dB @ frequency range, +30Vdc, room temp.
+30Vdc±1.0Vdc
Operating Voltage
+29Vdc ~ +31Vdc
RF Gain Variation over
Voltage & Temperature
±1.5dB @ +29≤Vsup≤+31V, -20℃ to +50℃
Gain Flatness
Peak to Peak 0.2dB over any 5MHz
Input/Output Return Loss
<-18dB
Output Protection
Efficiency
Mismatch protected with isolator
≥15%@+30Volts, Po=+52dBm
Operating Temperature
-30℃ to +55℃ (Air Temperature inside System),
Operating point
Input Power ALC
Output power:52dBm ± 0.5dB
Operating range
6dB min
Over Power
Output Pwr:52.5dBm ± 0.5dB
2. Alarm and Functions Specifications
TTL output for the alarm pins. Normal is High, Alarm is Low.
2.1.
Over temperature alarm
Alarm and shutdown at 95℃ base temperature, auto-recover at 90℃ base temperat
ure.
2.2.
Over power alarm
Alarm and shutdown when output power is over 52.5dBm, no auto-recover.
2.3. ALC
2.3.1. ALC level:
2.3.2. ALC range:
2.4.
52±0.5dBm
≥6dB
VSWR alarm
Alarm and shutdown when reject is over 5, auto-recover at 3.
Part E, Declare
The device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) this device not cause harmful interference, and (2) this device must accept any
interference received, including interference that many cause undesired operation.
Part F, Information to the User
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could
void to the user’s authority to operate the equipment.
This device must be installed by a professional installer.
The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent
structures.RF exposure compliance is addressed at the time of licensing, as required by the
responsible FCC Bureau(s) including antenna co-location requirements acc to §1.1307(b)(3).
Accessory, Sample of Test Procedure
1、Test equipment set up
1). Signal generator:
Agilent IFR3413
2). Spectrum analyzer:
ROHDE&SCHWARZ FSEA
3). Power meter:
Agilent E4418B/E8481A
4). Network analyzer
Agilent 8753E or R3765CH
2、 test condition description
1). Power supply cables and connectors:
Port Name
DC IN
Type
NO
DESCRIPTION
D-Sub type
DSCD175PS1M
(Male)
1、2
VDC
3、4
GND to VDC
2).Alarm ports (D-SUB DSCD175PS1M male connector)
Pin#1:
N.C
Pin#2:
BTI (do not contact anywhere)
Pin#3:
Over power alarm /over driver alarm /transistor fail alarm
Pin#4:
Over temperature alarm
Pin#5:
GND
Pin#6:
RF output power indication
Pin#7:
BTI (do not contact to anywhere)
Pin#8:
VSWR alarm
Pin#9:
Enable/Disable
3、 Checking item before testing
No seam on the surface of PA, the position and content of barcodes and labels are rig
ht.
Check the silk-screen of PA is correct and normal.
The connectors of power supply work normally and the poplars of positive and negative
are right.
RF connectors work normally.
Power switch is in the position of turnoff.
Turn on power supply and check the static current whose normal value should be 10A~
12A.
When the PA works with full power, the current should be 33A~35A.
4、RF performance test procedure:
1) Spectrum emission
Test flow chart:
Signal
Generator
30dB
Attenuator
LPA1900-120
-SC01
Cable2
Power
Supply
20dB
Attenuator
20dB
Attenuator
Cable1
10dB coupler
Spectrum
Analyzer
Cable3
Power
Meter
Figure 1
Purpose:
Check the quality of amplified signal.
Test setup list
Signal generator: Agilent IFR3413 or the same level instrumentation.
Power meter: Agilent E4418B or the same level instrumentation.
Spectrum analyzer: R&S FSEA or the same level instrumentation.
Power supply: 30V/50A
Attenuator: 30dB 500W 1PCS, 20dB 5W 2PCS,
Coupler: 60dB frequency range: 1930MHz~1990MHz
RF cable
Instruction
1. Set up the structure according to the figure 1.
2. Signal generator setup:
signal type:1. 3G 3Carriers
3FA, PAR:8.0dB
2. ats_3gpp_fdd_fwd_tm1_64ch_sc0_v5pt1
3. Spectrum analyzer setup:
RBW→30KHz, VBW→300KHz, Center frequency: 1960MHz, SPAN→40MHz, Sweep
time: 1S Spectrum Analyzer’s offset value according the attenuation from PA output to
input port of spectrum analyzer.
4. Power meter must to be calibration and set the offset value according to attenuation
from PA output to power sensor.
5. Input PA voltage setup +30V.
6. Turn on the signal generator.
7. Than confirm standard ACLR peculiarity.
2) Gain flatness
Test flow chart:
Signal
Generator
30dB
Attenuator
LPA19100-16
0-SC01
Cable2
Power
Supply
20dB
Attenuator
20dB
Attenuator
Cable1
10dB coupler
Spectrum
Analyzer
Cable3
Power
Meter
Figure 4
Purpose:
Check the gain at different frequency point.
Test setup list
Signal generator: IFR3413 or the same level instrumentation.
Power meter: Agilent E4418B or the same level instrumentation.
Spectrum analyzer: R&S FSEA or the same level instrumentation.
Power supply: 30V/50A
Attenuator: 30dB 500W 1PCS, 20dB 5W 2PCS,
Coupler: 60dB frequency range: 1930MHz~1990MHz
RF cable
3) Gain Variation & Detect Accuracy & Current consumption
Test flow chart:
Signal
Generator
30dB
Attenuator
LPA1900-160
-SC01
Cable2
Power
Supply
20dB
Attenuator
20dB
Attenuator
Cable1
10dB coupler
Cable3
Spectrum
Analyzer
Power
Meter
Figure 5
Purpose:
Check the variation of gain over voltage.
Measure the difference between forward power and detect power.
Measure the efficiency of PA.
Test setup list
Signal generator: IFR3413 or the same level instrumentation.
Power meter: Agilent E4418B or the same level instrumentation.
Spectrum analyzer: R&S FSEA or the same level instrumentation.
Power supply: 30V/50A
Attenuator: 30dB 500W 1PCS, 20dB 5W 2PCS,
Coupler: 60dB frequency range: 1930MHz~1990MHz
RF cable
Instruction
1. Set up the structure according to the figure 5.
2. Signal generator setup:
3. Spectrum analyzer setup:
RBW→30KHz, VBW→300KHz, Center frequency is 1960MHz, SPAN→40MHz, and
Spectrum Analyzer’s offset value according the attenuation from PA output to input port of
spectrum analyzer.
4. Power meter must to be calibration and set the offset value according to attenuation
from PA output to power sensor.
5. Input PA voltage setup +30V.
6. Turn on the signal generator; adjust the output power from -6.2dBm to -23dBm with
-1dB step.
7. Read out the output power from the power meter and do subtractions of each gain
and get the gain Variation.
9. Compare the value on the power meter with the value shown on GUI, and then get
the accuracy for different frequency range and different carriers.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2009:07:20 17:59:46+08:00
Create Date                     : 2009:07:20 17:59:18+08:00
Metadata Date                   : 2009:07:20 17:59:46+08:00
Format                          : application/pdf
Title                           : Microsoft Word - LPA1900-160-SC01 operation introduction.doc
Creator                         : 
Document ID                     : uuid:508ec81f-1fa9-4d47-874a-4069feab97cc
Instance ID                     : uuid:97121086-2ec2-4fca-94e3-a9bde67926a5
Page Count                      : 14
Author                          : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WBK1900-160

Navigation menu