Badger Meter 2002A Orion Integral/Remote User Manual ORION Remote and Integral p65

Badger Meter Inc Orion Integral/Remote ORION Remote and Integral p65

Exhibit D Users Manual per 2 1033 b3

TechnicalBriefBadgerMeter,Inc.®RTR-T-355-02DESCRIPTIONAPPLICATIONS: The assembled Badger® RTR® ORION® Integral  consistsof the Recordall® Transmitter Register (RTR) in a unique shroud whichincorporates the ORION RF Module.  When assembled, the product is fullyconfigured for use with Recordall disc series, turbo series and compoundseries water meters, (excluding Turbo I meter) which are installed as indoormeter settings, i.e., in basements, utility rooms, etc.  (This product is notdesigned for vault or meter pit installations which are subject to floodingor submergence.) Remote units can be also installed with Fire Servicemeters and assemblies.The assembled Integral RTR-ORION is designed to communicate withBadger interrogation devices, including handheld and mobile.The RTR-Remote ORION consists of the 3-wire (brown) RTR assemblywired to the ORION Remote.  This product is used in inside meter locationswhere the integral RTR-ORION assembly is not suitable, or in outsideapplications.OPERATION: The RTR provides a digital signal from Badger Meter'spatented piezoelectric solid-state switch. This signal has the characteristicsof an open drain Field Effect Transistor (FET) and has no electricalcontacts to stick, wear or corrode.  It is fully compatible with the inputcircuitry of the ORION RF Module. The ORION Integral and RemoteModules use the RF bubble-up (broadcast) mode.RESOLUTION: Digital output from the RTR has resolution of 1/10th of theregister test circle.  Output resolution of the ERT may vary with meter size.The resolution table on the back page of this technical brief lists outputresolution for all Recordall meter applications.LEAK DETECTION: The Orion system provides optional leak detectionnotification when the meter is read.  The system reports leak detectionwhen a two hour window of no usage is found within a 24 hour time period.The system automatically resets when the next two hour window of nousage is found.MOUNTING: The RTR-Integral ORION in its shroud assembly uses abayonet connection compatible with all Recordall® Disc, Turbo andCompound Series meters.  A TORX® seal screw is provided to allowpositioning and to secure the register to the meter body in a tamperresistant mode. The RTR-ORION can be removed from the meter withoutdisrupting water service.MAGNETIC DRIVE: Direct drive, high-strength, magnetic coupling throughthe meter body to the wetted magnet provides reliable and dependableregister coupling.SEALED REGISTER: The RTR local register consists of a six-digit straight-reading mechanical odometer totalizer, a 360° test circle with sweep hand,and a flow finder to detect leaks. The register gearing is self-lubricating,thermoplastic to minimize friction and provide long, reliable life. Permanentsealing eliminates moisture, dirt, and other contaminants.TAMPER-PROOF FEATURES: Removal of the RTR-Integral ORION fromthe meter can be minimized by using a tamper resistant TORX seal screw.TORX seal screws are provided as standard accessories with the RTR.Optional tamper detection seal wire screws are also available.CUT WIRE TAMPER INDICATION: The ORION remote/integral RF Modulehas the capability to detect a tamper should it exist. Proper setup in ORIONReading System software needed.CONSTRUCTION: The housing of the RTR is constructed of a temperedglass lens top and a copper alloy metal bottom. Internal constructionmaterials are thermoplastic for long-life and high reliability. The integrityof the adhesive seal joining the glass top to the metal base provideunmatched protection in water meter applications. A corrosion and tamperresistant TORX seal screw is provided to secure the RTR to the meter.  Theshroud assembly is polycarbonate.TEMPERATURE:  The operating range of the RTR is -40°C to 49°C (-40°Fto 120°F). The operating range of the Integral and Remote ORIONModules is -40°C to 60°C (-40°F to 140°F). The water meter should notbe subjected to temperatures below freezing.MOISTURE:  The RTR-Integral ORION is designed for dry applications,i.e., meters located in basements, utility rooms, etc.  The RTR-remoteORION can be mounted indoors or outdoors where it is not subjected tosubmergence.  It is not intended for outdoor meter pits or vaults.SPECIFICATIONSTransmitter/Register Straight reading, permanently sealed,magnetic driveUnit of Measure U.S. Gallons, Cubic Feet, Cubic Meters,clearly identified on register faceNumber Wheels Six with 3/16" high numeralsNamel font typeTest Circle 360° circle with ten major increments withten divisions eachWeight 9 OuncesHumidity 0% to 100% CondensingSignal Characteristics Open Drain (FET)Visual Resolution 1/100th of Test CircleElectronic Resolution 1/10th of Test CircleTypical Signal Duration 15 ms to 75 ms @ 25°C (77°F)8 ms to 75 ms over operating temperaturerange at 67 µAOn State Resistance 7.5 Ohms @ 25°C (77°F)Power Source ExternalMaximum Switching 30 VDC @ 1 mA @ 25°C (77°F)Battery on Integral and (2) 3.6V 2.4 Ahr Lithium BatteriesRemote ORIONSee Badger Technical Brief RTR-T-05 for RTR® specifications.RTR® - Integral ORION®RTR - Remote ORIONRecordall® Transmitter Register forORION® Integral or Remote
®Due to continuous research, product improvements and enhancements,Badger Meter reserves the right to change product or system specificationswithout notice, except to the extent an outstanding bid obligation exists.Copyright © Badger Meter, Inc. 2002. All rights reserved.Please see our website atwww.badgermeter.comfor specific contacts. BadgerMeter,Inc.P.O.  Box   245036,  Milwaukee,  WI  53224-9536(800) 876-3837 / Fax: (888) 371-5982www.badgermeter.comWIRE CONNECTIONS: The RTR can be factory prewired with pre-sized wire harness of up to 75 feet to the ORION® Remote.ELECTRONICS: The piezoelectric switch circuit board is completelysealed against moisture inside the unit and sealed to ensure protectionfrom humidity.  The ORION RF Module is coated to protect against theeffects of humidity.ELECTRICAL:  The electronic circuitry of the RTR and ORION RFModule is designed to provide immunity to electrical surges andtransients per IEC801-2, IEC801-4 Severity Level 4.OPERATING CHARACTERISTICS:  The RTR has an output equalto 1/10th of the meter test circle with the characteristics of an open drainFET. The on-state condition is a solid-state switch closure. Off-statecondition is an open circuit. Powered by an external source, the RTRhas a maximum rating of 30 VDC at 1 mA (25°C).PATENT: The Badger Meter RTR-Integral ORION package is coveredby U.S. Patent Nos. 348,384, 486,8566.TRANSPORTATION WARNING:  The Federal Aviation Administrationprohibits operating transmitters and receivers on all commercial aircraft.When powered, the Model RTR-ORION RF module is considered anoperating transmitter and receiver and cannot be shipped by air.MEASUREMENT RESOLUTION:  The minimum electronic resolutionof the RTR is noted below.  To verify the correct resolution for yourapplication, contact Badger Meter Customer Solutions.Resolution ResolutionRECORDALL Cubic CubicModel Size Gallons Feet (Ft3) Meters (m3)M25 5/8" 1 0.1 0.01M25 3/4" 1 0.1 0.01M35 3/4" 1 0.1 0.01M70 1" 1 0.1 0.01M120 1 1/2" 10 1 0.1M170 2" 10 1 0.1RECORDALL Resolution ResolutionTurbo Series Cubic Cubic(Size) Gallons Feet (Ft3) Meters (m3)2" 100 10 0.13" 100 10 0.14" 100 10 0.16" 100 10 18" 100 10 110" 100 1012" 1000 10016" 1000 10020" 1000 100RTR-Integral ORION Dimensional DrawingsRTR-Remote ORION Dimensional DrawingsMETER COMPATIBILITY: Badger Meter's Recordall® Disc, Turbo,and Compound Series meters for Integral and Remote. Remote canbe installed with Fire Service meters and assemblies.LICENSE REQUIREMENTSThis device complies with Part 15 of the FCC Rules.  Operation of thisdevice is subject to the following two conditions:  (1) This device maynot cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesiredoperation.  Any changes made by the user not approved by BadgerMeter can void the user's authority to operate the equipment. No licenseis required by the utility to operate a ORION meter reading system.Badger®, ORION®, Recordall®  and RTR® are registered trademarks of Badger Meter, Inc.TORX® is a registered trademark of Camcar, Division of Textron, Inc.2.695.205.804.72 SQ.25 TYP1234567890RNBADGER METERS4.584.676.436.393.90

Navigation menu