Badger Meter 2002A Orion Integral/Remote User Manual ORION Remote and Integral p65

Badger Meter Inc Orion Integral/Remote ORION Remote and Integral p65

Exhibit D Users Manual per 2 1033 b3

Download: Badger Meter 2002A Orion Integral/Remote User Manual ORION Remote and Integral p65
Mirror Download [FCC.gov]Badger Meter 2002A Orion Integral/Remote User Manual ORION Remote and Integral p65
Document ID250630
Application IDv1WvsYoi/5c4P12HjZHhaw==
Document DescriptionExhibit D Users Manual per 2 1033 b3
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize33.01kB (412597 bits)
Date Submitted2002-06-17 00:00:00
Date Available2002-06-14 00:00:00
Creation Date2002-05-31 13:50:58
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2002-05-31 13:50:59
Document TitleORION Remote and Integral.p65
Document CreatorPageMaker 6.5
Document Author: nowakca

RTR® - Integral ORION®
RTR - Remote ORION
Recordall® Transmitter Register for
ORION® Integral or Remote
Technical
Brief
DESCRIPTION
APPLICATIONS: The assembled Badger® RTR® ORION® Integral consists
of the Recordall® Transmitter Register (RTR) in a unique shroud which
incorporates the ORION RF Module. When assembled, the product is fully
configured for use with Recordall disc series, turbo series and compound
series water meters, (excluding Turbo I meter) which are installed as indoor
meter settings, i.e., in basements, utility rooms, etc. (This product is not
designed for vault or meter pit installations which are subject to flooding
or submergence.) Remote units can be also installed with Fire Service
meters and assemblies.
The assembled Integral RTR-ORION is designed to communicate with
Badger interrogation devices, including handheld and mobile.
The RTR-Remote ORION consists of the 3-wire (brown) RTR assembly
wired to the ORION Remote. This product is used in inside meter locations
where the integral RTR-ORION assembly is not suitable, or in outside
applications.
OPERATION: The RTR provides a digital signal from Badger Meter's
patented piezoelectric solid-state switch. This signal has the characteristics
of an open drain Field Effect Transistor (FET) and has no electrical
contacts to stick, wear or corrode. It is fully compatible with the input
circuitry of the ORION RF Module. The ORION Integral and Remote
Modules use the RF bubble-up (broadcast) mode.
RESOLUTION: Digital output from the RTR has resolution of 1/10th of the
register test circle. Output resolution of the ERT may vary with meter size.
The resolution table on the back page of this technical brief lists output
resolution for all Recordall meter applications.
LEAK DETECTION: The Orion system provides optional leak detection
notification when the meter is read. The system reports leak detection
when a two hour window of no usage is found within a 24 hour time period.
The system automatically resets when the next two hour window of no
usage is found.
MOUNTING: The RTR-Integral ORION in its shroud assembly uses a
bayonet connection compatible with all Recordall® Disc, Turbo and
Compound Series meters. A TORX® seal screw is provided to allow
positioning and to secure the register to the meter body in a tamper
resistant mode. The RTR-ORION can be removed from the meter without
disrupting water service.
MAGNETIC DRIVE: Direct drive, high-strength, magnetic coupling through
the meter body to the wetted magnet provides reliable and dependable
register coupling.
SEALED REGISTER: The RTR local register consists of a six-digit straightreading mechanical odometer totalizer, a 360° test circle with sweep hand,
and a flow finder to detect leaks. The register gearing is self-lubricating,
thermoplastic to minimize friction and provide long, reliable life. Permanent
sealing eliminates moisture, dirt, and other contaminants.
TAMPER-PROOF FEATURES: Removal of the RTR-Integral ORION from
the meter can be minimized by using a tamper resistant TORX seal screw.
TORX seal screws are provided as standard accessories with the RTR.
Optional tamper detection seal wire screws are also available.
CUT WIRE TAMPER INDICATION: The ORION remote/integral RF Module
has the capability to detect a tamper should it exist. Proper setup in ORION
Reading System software needed.
CONSTRUCTION: The housing of the RTR is constructed of a tempered
glass lens top and a copper alloy metal bottom. Internal construction
materials are thermoplastic for long-life and high reliability. The integrity
of the adhesive seal joining the glass top to the metal base provide
unmatched protection in water meter applications. A corrosion and tamper
resistant TORX seal screw is provided to secure the RTR to the meter. The
shroud assembly is polycarbonate.
TEMPERATURE: The operating range of the RTR is -40°C to 49°C (-40°F
to 120°F). The operating range of the Integral and Remote ORION
Modules is -40°C to 60°C (-40°F to 140°F). The water meter should not
be subjected to temperatures below freezing.
SPECIFICATIONS
Transmitter/Register
Straight reading, permanently sealed,
magnetic drive
Unit of Measure
U.S. Gallons, Cubic Feet, Cubic Meters,
clearly identified on register face
Number Wheels
Six with 3/16" high numerals
Namel font type
Test Circle
Weight
Humidity
Signal Characteristics
Visual Resolution
Electronic Resolution
Typical Signal Duration
On State Resistance
Power Source
Maximum Switching
Battery on Integral and
Remote ORION
360° circle with ten major increments with
ten divisions each
9 Ounces
0% to 100% Condensing
Open Drain (FET)
1/100th of Test Circle
1/10th of Test Circle
15 ms to 75 ms @ 25°C (77°F)
8 ms to 75 ms over operating temperature
range at 67 µA
7.5 Ohms @ 25°C (77°F)
External
30 VDC @ 1 mA @ 25°C (77°F)
(2) 3.6V 2.4 Ahr Lithium Batteries
See Badger Technical Brief RTR-T-05 for RTR® specifications.
MOISTURE: The RTR-Integral ORION is designed for dry applications,
i.e., meters located in basements, utility rooms, etc. The RTR-remote
ORION can be mounted indoors or outdoors where it is not subjected to
submergence. It is not intended for outdoor meter pits or vaults.
BadgerMeter,Inc.
®
RTR-T-35
5-02
WIRE CONNECTIONS: The RTR can be factory prewired with presized wire harness of up to 75 feet to the ORION® Remote.
.25
TYP
ELECTRONICS: The piezoelectric switch circuit board is completely
sealed against moisture inside the unit and sealed to ensure protection
from humidity. The ORION RF Module is coated to protect against the
effects of humidity.
5.20
ELECTRICAL: The electronic circuitry of the RTR and ORION RF
Module is designed to provide immunity to electrical surges and
transients per IEC801-2, IEC801-4 Severity Level 4.
4.72
SQ
5.80
OPERATING CHARACTERISTICS: The RTR has an output equal
to 1/10th of the meter test circle with the characteristics of an open drain
FET. The on-state condition is a solid-state switch closure. Off-state
condition is an open circuit. Powered by an external source, the RTR
has a maximum rating of 30 VDC at 1 mA (25°C).
PATENT: The Badger Meter RTR-Integral ORION package is covered
by U.S. Patent Nos. 348,384, 486,8566.
2.69
TRANSPORTATION WARNING: The Federal Aviation Administration
prohibits operating transmitters and receivers on all commercial aircraft.
When powered, the Model RTR-ORION RF module is considered an
operating transmitter and receiver and cannot be shipped by air.
MEASUREMENT RESOLUTION: The minimum electronic resolution
of the RTR is noted below. To verify the correct resolution for your
application, contact Badger Meter Customer Solutions.
RTR-Remote ORION Dimensional Drawings
4.67
0.1
0.01
M25
3/4"
0.1
0.01
M35
3/4"
0.1
0.01
M70
1"
0.1
0.01
M120
1 1/2"
10
0.1
M170
2"
10
0.1
RECORDALL
Turbo Series
(Size)
Gallons
Resolution
Cubic
Feet (Ft3)
Resolution
Cubic
Meters (m3)
2"
100
10
0.1
3"
100
10
0.1
4"
100
10
0.1
6"
100
10
M25
6.43
5/8"
Size
6.39
Resolution
Cubic
Meters (m3)
4.58
Gallons
Resolution
Cubic
Feet (Ft3)
RECORDALL
Model
BADGER METER
1234567890
3.90
RTR-Integral ORION Dimensional Drawings
8"
100
10
10"
100
10
12"
1000
100
16"
1000
100
20"
1000
100
METER COMPATIBILITY: Badger Meter's Recordall® Disc, Turbo,
and Compound Series meters for Integral and Remote. Remote can
be installed with Fire Service meters and assemblies.
LICENSE REQUIREMENTS
This device complies with Part 15 of the FCC Rules. Operation of this
device is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired
operation. Any changes made by the user not approved by Badger
Meter can void the user's authority to operate the equipment. No license
is required by the utility to operate a ORION meter reading system.
Badger®, ORION®, Recordall ® and RTR® are registered trademarks of Badger Meter, Inc.
TORX® is a registered trademark of Camcar, Division of Textron, Inc.
Please see our website at
Due to continuous research, product improvements and enhancements,
Badger Meter reserves the right to change product or system specifications
without notice, except to the extent an outstanding bid obligation exists.
www.badgermeter.com
BadgerMeter,Inc.
for specific contacts.
Copyright © Badger Meter, Inc. 2002. All rights reserved.
®
P.O. Box 245036, Milwaukee, WI 53224-9536
(800) 876-3837 / Fax: (888) 371-5982
www.badgermeter.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Fill forms, Extract, Assemble, Print high-res
Create Date                     : 2002:05:31 13:50:58
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : nowakca
Creator                         : PageMaker 6.5
Title                           : ORION Remote and Integral.p65
Modify Date                     : 2002:05:31 13:50:59-05:00
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GIF2002A

Navigation menu