   EP3011  Quick  Installation  Guide
 1  1. Product Overview 1.1 Interface (1) Interfaces  (2) LEDs   Interface & Button  Description SW  Power On/Off POWER  24VDC, 1A WAN  1  RJ45,  WAN  10/100/1000  auto-sensing,  auto-MDX,  24V 0.5A PoE RST  Long press over 10 seconds to restore factory settings LAN  2 RJ45, LAN 10/100 auto-sensing, auto-MDX  No. Name Status Description 1  Power Steady On Power On OFF No Power Supply 2  WLAN Steady On Wi-Fi enabled OFF Wi-Fi disabled Blinking Wi-Fi is starting 3 LTE (if connect to LTE ODU) Steady On LTE is connected OFF LTE is disconnected Blinking  LTE is starting
   No. Name Status Description 4 Signal (if connect to LTE ODU) Steady On The more the lights on, the stronger the signal OFF No signal or weak signal Blinking Only the first LED on the left is blinking  Scanning the LTE network The two LEDs on the left are blinking Attaching to the LTE network Three LEDs blinking Attached successfully
   2. Specifications Item  Description Standard  IEEE 802.11b/g/n/ac(WA) or 802.11bgn(WN) Channel Bandwidth  20MHz, 40MHz or 20MHz, 40MHz, 80MHz Frequency  2.4GHz, 5GHz or 2.4G only TXRX  2T2R MIMO  2×2 Peak Rate 802.11b: 11Mbps 802.11g: 54Mbps 802.11n: 300Mbps 802.11ac: 866Mbps Modulate  DSSS/CCK, OFDM Sensitivity -64 dBm@65Mbit/s, typical for 802.11n/ac -65 dBm@54Mbit/s, typical for 802.11g -76 dBm@11Mbit/s, typical for 802.11b Antenna Type  Internal omni-antenna Antenna Gain  5dBi
   3. Installation Guide 3.1 Support Materials Before installation, prepare the following support materials: Item  Description Ethernet cable  Outdoor Shield CAT5E Shorter than 330 feet Ground wire  16mm² yellow-green wire 3.2 Installation  CAUTION: NO OTHER DEVICES ARE ALLOWED TO BE CONNECT WITH IDU’s WAN PORT EXCEPT BAICELLS’ OUD PRODUCTS (EG7035E/L and EG7010A/C) Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
   4. Configuration Guide 4.1 Log in The EP3011 manages, configures, and maintains the device by web management page. The steps to log in are as follows: 1.  In the address column of browser, type in http://192.168.150.1, then press “Enter”, login in page is shown in Figure 4-1. Figure 4-1 Login Page   2.  Enter the user name and password, click "LOGIN". After password authentication, you can log on to the web management page. The default user name and password is admin. For security, it is recommended that you open the firewall, and keep your login password, WLAN FTP passwords and password well. 4.2 View Status In the overview area, you can view the device information and LTE status, such as Product name, Software version, PLMN, IMSI, RSRP, RSRQ, CINR, SINR, Tx Power, Cell ID, PCI, and so on, as shown in Figure 4-2.
   Figure 4-2 View Status   4.3 Basic Configuration 4.3.1 LTE Setting To set the LTE Network, perform the following steps: 1.  Choose LTE.   2.  In the LTE Setting area, configure the LTE network.   4.3.2 Set Connection Method To set the LTE network connection method, perform the following steps: 1.  Choose “LTE>connection Method”, enter the setting connection method page, as shown in Figure 4-3. Figure 4-3 Set Connection Method
   2.  In the connection Method area, set the connection method 3.  There are two methods to connect the LTE network, it is needed to choose a method between Auto and Manual, if you want to auto connect to the LET network you should choose the Auto, otherwise you should choose Manual.   4.  Click “SAVE & APPLY”.
   Regulatory Compliance FCC Compliance This  device  complies  with  part  15  of  the  FCC  Rules.  Operation  is  subject  to  the following two conditions: (1) This device may not cause harmful interference, and (2) this  device must accept  any  interference received, including interference that may cause undesired operation.  Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part  15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed  and  used  in  accordance  with  the  instructions,  may  cause  harmful interference  to  radio  communications.  However,  there  is  no  guarantee  that interference will not  occur in  a particular  installation. If this  equipment does cause harmful  interference  to  radio  or  television  reception,  which  can  be  determined  by turning  the  equipment  off  and  on,  the  user  is  encouraged  to  try  to  correct  the interference by one or more of the following measures:   Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.      Consult the dealer or an experienced radio/TV technician for help. Warning This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an uncontrolled  environment.  This  equipment  should  be  installed  and  operated  with minimum distance 20 cm between the radiator & your body. ISEDC Compliance This device complies with Innovation, Science, and Economic Development Canada licence-exempt RSS standard(s).  Operation is subject to the following two conditions:  (1) This device may not cause interference, and  (2) This device must accept any interference, including interference that may cause undesired operation of the device.
    Le présent appareil est conforme aux CNR d'Innovation, Science et Développement économique Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:   (1) l'appareil ne doit pas produire de brouillage, et  (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,  même si le brouillage est susceptible d'en compromettre le fonctionnement.  The  antenna(s) used  for  this  transmitter  must be  installed to  provide  a  separation distance of at least 20cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter, End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.