User Manual
GENERAL VIEW INSTALLATION GUIDELINES LED INDICATORS COBALT C0405-232-01 COM RF High Frequency Passive Radio Frequency, Identification Controller Select a suitable location to mount the C0405 Controller. C0405 Series RFID Controllers can be mounted to wood or plastic fixtures. The C0405 may be mounted horizontally or vertically, but should be aligned in such a manner that the LED indicators can be seen during operation. RF performance and read/write range can be negatively impacted by the proximity of metallic objects. Avoid mounting the controller within 5 cm (2 in.) of any metallic object or surface. Do not route cables near other unshielded cables or near wiring carrying high voltage or high current. Cross cables at perpendicular intersections and avoid routing cables near motors and solenoids. Avoid mounting the controller near sources of EMI (electro-magnetic interference) or near devices that generate high ESD (electro-static discharge) levels. Always use adequate ESD prevention measures to dissipate potentially high voltages. If electrical interference is encountered (as indicated by a significant reduction in read/write performance), relocate the controller to an area free from potential sources of interference. When installing multiple RFID controllers that operate at the same frequency (13.56 MHz), maintain a minimum distance of 20 cm (8 in.) between adjacent RF devices. RS232 Power Bottom QUICK REFERENCE GUIDE C0405 This document provides instructions and information designed to assist users in the hardware setup of the Cobalt C0405232-01 RFID Controller. For configuration details download the C-Series Reference Manual from the product page at www.automation.datalogic.com. Antenna Field Top CONNECTIVITY TECHNICAL FEATURES Cobalt C0405-232-01 M12 8-pin Male Connector Typical Layout ELECTRICAL FEATURES Power Supply DC Input Current Communication Interface RADIO FEATURES Frequency Air Protocols CBL-1478 10 to 30 VDC 150 to 60 mA RS232 INSTALLATION 13.56 MHz ISO 14443A, ISO 15693 C0405 1. Attach the C0405 Controller to the polycarbonate mounting bracket (for metallic isolation) using the two sets of M4 screws, washers and nuts provided as shown in the mounting figure. Fasten the other end of the mounting bracket to your work area. Tighten all screws to 0.7 Nm (6 lbs per inch). 2. Connect the CBL-1478 M12 8-pin female connector to the M12 8-pin male connector on the C0405. Connect the CBL-1478 9-pin female D-sub connector to an RS232 COM port on the host computer. Tighten the cable’s two locking thumbscrews. 3. Connect the power supply to the VDC (red) and GND (black) wires on the CBL-1478 cable. 4. Apply power to the controller after all cable connections have been made. The LEDs on the unit will flash. 5. On the host computer, set COM port parameters to: 9600 baud, 8 data bits, 1 stop bit, no parity and no handshaking. Host ENVIRONMENTAL FEATURES Operating Temperature Storage Temperature Humidity max. Vibration Resistance EN 60068-2-6 Shock Resistance EN 60068-2-27 Protection Class EN 60529 -20° to +50 °C (-4° to +122 °F) -20° to +70 °C (-4° to +158 °F) 90% non condensing 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2 g @ 70 to 200 Hz; 2 hours on each axis 30 g; 11 ms; 3 shocks on each axis VDC (red) GND (black) See the C-Series Reference Manual for a complete list of accessories including alternative cables and connectors. MECHANICAL DIMENSIONS Weight MOUNTING IP67 39.2 [1.54] PHYSICAL FEATURES Dimensions 67 x 40 x 24 mm (2.64 x 1.57 x .94 in) 47 g (1.7 oz) 24 [0.94] 14.3 [0.56] 15.5 [0.61] 12.5 [0.49] USER INTERFACE LED Indicators Power Supply RF, COM, Operating Mode/Diagnostic, Power 67 [2.64] 40 [1.57] 28 [1.10] Ø4.5 MOUNTING HOLE 2X [Ø.18] mm [in] To verify operations, download the Cobalt Dashboard™ Utility from www.automation.datalogic.com. The Cobalt Dashboard™ Utility allows users to configure and control their C0405 controllers and send RFID commands for testing purposes. UPDATES AVAILABILITY UK/US The latest documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com Su Internet sono disponibili le versioni aggiornate di documentazione di questo prodotto. Collegarsi a: www.automation.datalogic.com Les versions mises à jour de documentation de ce produit sont disponibles sur Internet. Cliquez sur: www.automation.datalogic.com Im Internet finden Sie die aktuellsten Versionen der Dokumente zu diesem Produkt. Adresse: www.automation.datalogic.com COMPLIANCE FCC Compliance This product is intended to be installed by Qualified Personnel only. Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This product must not be used in explosive environments. See the C-Series Reference Manual for the Declaration of Conformity. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. Power Supply FCC ID: E36-0005 This device is intended to be supplied by a UL Listed or CSA Certified Power Unit with «Class 2» or LPS power source. Radio Compliance En Internet están disponibles las versiones actualizadas de la documentación de este producto. Dirección Internet: www.automation.datalogic.com ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required. For further information, refer to the web site: http://ec.europa.eu/enterprise/sectors/rtte/ ITALIANO Prendi contatto con l'autorità competente per la gestione degli apparati a radio frequenza del tuo paese, per verificare eventuali restrizioni o licenze. Ulteriori informazioni sono disponibili sul sito: http://ec.europa.eu/enterprise/sectors/rtte/ This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FRANÇAIS Contactez l'autorité compétente en la gestion des appareils à radio fréquence de votre pays pour vérifier d'éventuelles restrictions ou licences. Pour tout renseignement vous pouvez vous adresser au site web: http://ec.europa.eu/enterprise/sectors/rtte/ SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information: PRODUCTS Search through the links to arrive at your product page which describes specific Info, Features, Applications, Models, Accessories, and Downloads including the Cobalt Dashboard™ utility program, which allows system testing, monitoring, and configuration using a PC. It provides Serial (RS232 or USB) and Ethernet interface configuration. SERVICE - Overview - Warranty Extensions and Maintenance Agreements - Sales Network - Listing of Subsidiaries, Repair Centers, Partners - Helpdesk - Material Return Authorization DEUTSCH Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres Landes, um zu prüfen ob es Einschränkungen gibt, oder eine Lizenz erforderlich ist. Weitere Informationen finden Sie auf der Web Seite: http://ec.europa.eu/enterprise/sectors/rtte/ ESPAÑOL Contacta la autoridad competente para la gestión de los dispositivos de radio frecuencia de tu país, para verificar cualesquiera restricciones o licencias posibles requerida. Además se puede encontrar mas información en el sitio: Web: http://ec.europa.eu/enterprise/sectors/rtte/ LEGAL NOTICES © 2010 - 2012 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic Automation S.r.l. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Subnet16, Cobalt Dashboard and Cobalt C-Macro Builder are trademarks of Datalogic Automation S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material. Datalogic Automation S.r.l. Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy Tel: +39 051 6765611 - Fax: +39 051 6759324 www.automation.datalogic.com e-mail: info.automation@datalogic.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2012:03:12 09:18:51+01:00 Create Date : 2012:03:12 09:18:51+01:00 Format : application/pdf Title : Microsoft Word - C0405-232-01 Quick Reference Guide.DOC Creator : ESchino Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:a0e5c9ec-3cc1-49c6-a717-5be0b5f19129 Instance ID : uuid:a420eda3-04a4-454c-81b0-7d960f9130ac Page Count : 2 Author : ESchinoEXIF Metadata provided by EXIF.tools