Banner Engineering Q240RA Q240RA-US-AF2Q and Q240RA-US-AF2 User Manual

Banner Engineering Corporation Q240RA-US-AF2Q and Q240RA-US-AF2

User Manual

DatasheetRadar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary Targets• FMCW (true-presence) radar detects moving and stationary objects• Narrow 11° × 13° beam pattern• Two independent, adjustable sensing zones detect objects up to 40 metersaway (131.2 ft)• Easy setup and configuration of range, sensitivity, and output with simple DIPswitches• Sensing functions are unaffected by wind, falling rain or snow, fog, humidity,air temperatures, or light• Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunicationband• Rugged IP67 housing withstands harsh environmentsProtected by US patentsModel SensingRange Connection SupplyVoltage Telecom Approval OutputQ240RA-US-AF2Q Twoindependentsensingzones; 1 to40+ meters(131 ft)5-pin M12quickdisconnect12 to 30 VdcTelecom approved for US and CanadaDIP-switch-selectable NPN orPNP; N.O. or N.C.Q240RA-CN-AF2Q Telecom approved for ChinaCAUTION: Make No Modifications to this ProductAny modifications to this product not expressly approved by Banner Engineering could void the user'sauthority to operate the product. Contact Banner Engineering for more information.WARNING: Not To Be Used for Personnel ProtectionNever use this device as a sensing device for personnel protection. Doing so could lead toserious injury or death. This device does not include the self-checking redundant circuitry necessaryto allow its use in personnel safety applications. A sensor failure or malfunction can cause either anenergized or de-energized sensor output condition.OverviewThe R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of thisemitted energy is reflected back to the receiving antenna. Signal processing electronics determine the distance from thesensor to the object based on the time delay of the return signal. The sensor can be configured to two independentsensing zones.The two sensing zones are factory pre-set to default distances; they can be reconfigured for different distances using theDIP switches on the side of the sensor. The sensor is plug-in ready for immediate operation.The sensitivity is precalibrated at the factory, assuming that the sensing field will be clear of obstacles. The sensitivity canbe adjusted using the DIP switches on the side of the sensor.R-GAGE™ Q240RA-AF2 Sensor    Original Document184564 Rev. A 22 September 2015184564
125634Figure 1. R-GAGE features1. Output LEDs: Yellow (output 1 energized); Red(configuration)2. Output LEDs: Yellow (output 2 energized); Red(configuration)3. Power LED: Green (power ON)4. Signal Strength LED: Red (flashes in proportion tothe signal strength)5. DIP switch row A6. DIP switch row BAccess the DIP switches behind the threaded cap on thesensor sideDX YA BZone 1 Zone 2Figure 2. R-GAGE setpoint distancesCN Model US ModelX Minimum Zone 1 setpoint distance 2 m (6.6 ft) 3.5 m (11.5 ft)Y Maximum Zone 1 setpoint distance 30 m (98.4 ft) 30 m (98.4 ft)A Minimum Zone 2 (offset from Zone 1: 2 m to 25 m) 4 m (13.1 ft) 5.5 m (18.0 ft)B Maximum Zone 2 (offset from Zone 1: 2 m to 25 m) 55 m (180.4 ft) 55 m (180.4 ft)D Dead Zone1Sensor ConfigurationUse the included spanner to open the screw-off cover on the side of the sensor and access the DIP switches.Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertightseal.1Typical dead zone: 0.4 m (1.3 ft) for moving and 1.0 m (3.3 ft) for stationary targets, but varies with target reflectivity.    R-GAGE™ Q240RA-AF2 Sensor2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 184564 Rev. A
DIP Switch FunctionsSwitches FunctionA1, A2, A3, A4 Zone 1 Distance (detects objects from sensor face to this point)A5, A6, A7 Zone 2 Distance, Offset from Zone 1A8 PolarityB1, B2, B3 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern)B4, B5, B6 Response SpeedB7 Normally Open/Normally Closed output functionalityB8 Not UsedDIP switch 1 is on the left and DIP switch 8 is on the right.Distance SettingsZone 1 DistanceA1 A2 A3 A4 DistanceCN US0 0 0 0 2 m (6.6 ft) 3.5 m (11.5 ft)0 0 0 1 2.5 m (8.2 ft) 4 m (13.1 ft)0 0 1 0 3 m (9.8 ft) 4.5 m (14.8 ft)0 0 1 1 3.5 m (11.5 ft) 5 m (16.4 ft)0 1 0 0 4 m (13.1 ft) 5.5 m (18.0 ft)0 1 0 1 5 m (16.4 ft) 6 m (19.7 ft)0 1 1 0 6 m (19.7 ft) 6.5 m (21.3 ft)0 1 1 1 7 m (23.0 ft) 7 m (23.0 ft)1* 0* 0* 0* 8 m (26.2 ft) 8 m (26.2 ft)1 0 0 1 10 m (32.8 ft) 10 m (32.8 ft)1 0 1 0 12 m (39.4 ft) 12 m (39.4 ft)1 0 1 1 14 m (45.9 ft) 14 m (45.9 ft)1 1 0 0 16 m (52.5 ft) 16 m (52.5 ft)1 1 0 1 20 m (65.6 ft) 20 m (65.6 ft)1 1 1 0 25 m (82.0 ft) 25 m (82.0 ft)1 1 1 1 30 m (98.4 ft) 30 m (98.4 ft)* Default settingsR-GAGE™ Q240RA-AF2 Sensor    P/N 184564 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 3
Zone 2 Distance Offset from Zone 1A5 A6 A7 Offset0 0 0 2 m (6.6 ft)0 0 1 4 m (13.1 ft)0 1 0 6 m (19.7 ft)0* 1* 1* 8 m (26.2 ft)1 0 0 10 m (32.8 ft)1 0 1 15 m (49.2 ft)1 1 0 20 m (65.6 ft)1 1 1 25 m (82.0 ft)NOTE: Highest sensitivity is achieved only if the sensing distance is 36 m (118.1 ft) or less.Sensitivity SelectionB1 B2 B3 Sensitivity0 0 0 8 (Highest)0 0 1 7...0 1 0 6 (High)0 1 1 5...1 * 0 * 0 * 4 (Medium)1 0 1 3...1 1 0 2 (Low)1 1 1 1 (Lowest)* Default settingsNOTE: Operation at a high sensitivity not guaranteed for a zone set beyond 45 m (147.6 ft)Output ConfigurationA8 NPN / PNP0* NPN1 PNP* Default settingsB7 Normally Open / Closed0* NO1 NCResponse SpeedB4 B5 B6 ON Total (ms) OFF Total (ms) Total (ms)0 0 0 15 15 300 0 1 30 70 1000 1 0 30 120 1500* 1* 1* 50 300 350    R-GAGE™ Q240RA-AF2 Sensor4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 184564 Rev. A
B4 B5 B6 ON Total (ms) OFF Total (ms) Total (ms)1 0 0 50 600 6501 0 1 30 1000 10301 1 0 120 600 7201 1 1 120 6000 6120* Default settingsSpecificationsRangeThe sensor is able to detect a proper object (see Detectable Objects)from 1 to 40+ m (3.3 to 131.2+ ft), depending on targetDetectable ObjectsObjects containing metal, water, or similar high-dielectric materialsOperating PrincipleFrequency modulated continuous-wave (FMCW) radarOperating Frequency24.00 to 24.25 GHz, ISM Band (varies slightly with model, dependingon national telecom regulations)Supply Voltage12 to 30 V dc, less than 100 mA, exclusive of loadSupply Protection CircuitryProtected against reverse polarity and transient overvoltagesDelay at Power-upLess than 2 secondsOutput ConfigurationDIP switch A8 selects Dual NPN (default) or PNP; DIP switch B7 selectsN.O. (default) or N.C. operation; 150mA each· Zone 1 output: white wire· Zone 2 output: black wireOutput ProtectionProtected against short circuit conditionsResponse TimeDIP-switch-configurable ON/OFF response timeIndicatorsPower LED: Green (power ON)Signal Strength LED: Red, flashes in proportion to signal strength.Steady on at 4x excess gain. Only indicates signal amplitude, nottarget distance.Output LEDs: Yellow (output energized) / Red (configuration)See Overview on page 1AdjustmentsDIP-switch-configurable sensing distance, sensitivity, response time,and output configurationConstructionHousing: PolycarbonateLightpipes: AcrylicAccess Cap: PolyesterOperating Temperature– 40° to + 65° C (– 40° to + 149° F)Environmental RatingIP67ConnectionsIntegral M12 Euro-style QD fitting. QD models require a mating cordsetCertificationsCMIIT Category G, FCC part 15, RSS-210, others pendingBeam AnglesSIDE TOPFCC ID: UE3Q240RAUS—This device complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received,including interference that may cause undesired operation.IC: 7044A-Q240RA—This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject tothe following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,including interference that may cause undesired operation of the device.Cet appareil est conforme aux CNR exempts de licence d'Industrie Canada. Son fonctionnement est soumis aux deuxconditions suivantes: (1) Ce dispositif ne peut causer des interférences; et (2) Ce dispositif doit accepter touteinterférence, y compris les interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil.R-GAGE™ Q240RA-AF2 Sensor    P/N 184564 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 5
Beam PatternTypical Beam Pattern (with BRTR-CC20E RadarTarget, Radar Cross Section = 50 m2)Typical Beam Pattern (with 4 different targets)00-1-2-33215 10 15 20 25Meters30 35 40 45MetersSensitivity 1Sensitivity 8812345671–8: Indicates sensitivity level00-1-2-3-4-5-64365215 10 15 20 25Meters30 35 40 45MetersWeak ObjectCarLarge TruckPassenger Train4321At sensitivity level 81: Weak Object (Radar cross section = 0.25 m2)2: Car (Radar cross section = 3 m2)3: Large Truck (Radar cross section = 50 m2)4: Passenger Train (Radar cross section = 300 m2)00-1-2-3-4-5-64365215 10 15 20 25Meters30 35 40 45MetersCarLarge TruckPassenger Train432Weak Object(Trace Data)1At sensitivity level 4NOTE: The effective beam pattern depends on the sensitivity level and target properties.    R-GAGE™ Q240RA-AF2 Sensor6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 184564 Rev. A
DimensionsAll measurements are listed in millimeters (inches), unless noted otherwise.WindowsThe R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and thedistance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20%signal reduction when the sensor is placed behind a window.Polycarbonate at 4 mm thickness performs well in most situations, but the performance depends on filler materials.Thinner (1 to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, anddistance from the sensor to the window.Locate the sensor in a position of minimum reflection from the window, which will repeat every 6.1 mm of distancebetween the sensor and the window. The positions of maximum reflection from the window repeat between the minimums,and decrease in effect until the window is approximately 150 mm (5.9 in) away. Consult the factory for pre-tested windowmaterials which can be used at any distance without issue.Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hooddirectly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on theface of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face ofthe window can be detected as a dielectric boundary.The Q240WS is a clip-on hydrophobic weather shield accessory specially designed to meet these requirements.R-GAGE™ Q240RA-AF2 Sensor    P/N 184564 Rev. A www.bannerengineering.com - Tel: +1-763-544-3164 7
Wiringshield (QD cordset)3124512-30V dcLoad 1Load 2+–Wiring Key:1. Brown2. White3. Blue4. Black5. Gray (Do not connect)NOTE: Banner recommends that the shield wire(QD cordsets only) be connected to earth groundor dc common. Shielded cordsets arerecommended for all QD models.AccessoriesQuick Disconnect (QD) Cordsets5-Pin Threaded M12/Euro-Style Cordsets—with ShieldModel Length Style Dimensions Pinout (Female)MQDEC2-506 1.83 m (6 ft)Straight44 Typ.ø 14.5M12 x 1234151 = Brown2 = White3 = Blue4 = Black5 = GrayMQDEC2-515 4.57 m (15 ft)MQDEC2-530 9.14 m (30 ft)MQDEC2-550 15.2 m (50 ft)MQDEC2-506RA 1.83 m (6 ft)Right-Angle32 Typ.[1.26"]30 Typ.[1.18"]ø 14.5 [0.57"]M12 x 1MQDEC2-515RA 4.57 m (15 ft)MQDEC2-530RA 9.14 m (30 ft)MQDEC2-550RA 15.2 m (50 ft)NOTE: Pin 5 is not used.Brackets and Other AccessoriesSMBQ240SS2• Add-on accessory to beused in conjunction withSMBQ240SS1• Provides ± 20° of tilt insecond axis for maximumcontrol of sensor alignment• 12 gauge stainless steelQ240WS• Coated to help repel waterand maximize signalstrength• Snap-on cover for easyapplication and replacement    R-GAGE™ Q240RA-AF2 Sensor8 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 184564 Rev. A
SMBQ240SS1• Sensor mounting plate andpivoting bracket• Provides ± 20° of tilt in oneaxis for enhanced sensoralignment• 12 gauge stainless steel• Sensor can mount onbracket horizontally orverticallyQ240RA R-GAGE sensor shown with all three accessoriesinstalled.Banner Engineering Corp Limited WarrantyBanner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year followingthe date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacturewhich, at the time it is returned to the factory, is found to have been defective during the warranty period. This warrantydoes not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS ORIMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING ORTRADE USAGE.This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NOEVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FORANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL ORSPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THEPRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,NEGLIGENCE, OR OTHERWISE.Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming anyobligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.   R-GAGE™ Q240RA-AF2 Sensor  www.bannerengineering.com - Tel: +1-763-544-3164

Navigation menu