G U I DA N C E N OT E S Solar Collectors In-Roof Tile Installation (First Fix) Please leave these instructions with the User © Baxi Heating UK Ltd 2011 Contents 2 © Baxi Heating UK Ltd 2011 1.0 Legislation 3 2.0 General Layout 4 3.0 Icon Quick Reference Guide 5 4.0 Dimensions 6 5.0 Health & Safety 8 6.0 Snow & Wind Load 11 7.0 Optimum Pipework Assembly 12 8.0 Kit Contents and Components 13 9.0 Installation of the Collector 16 10.0 Fixing the Flashing 20 11.0 Maintenance 24 1.0 Legislation Please note the following instructions regarding laws, regulations and technical rules. When setting up solar energy installations, the laws and regulations at local, state, European and international level that apply to the country in question must be observed. Generally acknowledged technical regulations apply; these are usually formulated in the form of standards, guidelines, provisions, regulations and technical rules laid down by local and national bodies, energy supply companies, trade organisations and technical committees in the relevant fields. The installation of solar units may require improved rain resistance with regard to roof, wall and sealing technology and this must be taken into account accordingly. To meet regulations for the prevention of accidents, it may be necessary to use safety equipment (straps, scaffolding, supports, etc.). Such safety equipment is not supplied and must be ordered separately. Installation must only be carried out by technically qualified and authorised personnel with a recognised qualification (verified by a state or national body) in the relevant technical area. Use a safety harness when working at height. The structure of the roof must be assessed for its suitability prior to commencing work. This product is unclassified against BS 476-3. Consult a Structural Engineer if you are unsure of the collector’s siting. Loading due to snow may exceed the capability of the property’s structure. Wind loads may cause excess forces on the structure and cause damage. The Installer is responsible for the suitability of the site and its sub-structure. The collector should be sited to avoid damage from falling debris and vandalism. All pipe work within this installation must be Earth bonded. In exposed areas, the collector must be protected against the risk of lightning. It is recommended that a minimum of 2 people are used to lift this product. The collector must not be lifted by its pipe connections. Ensure all hydraulic connections are securely fixed and are free of leaks. The system must be inspected on completion of the work. A further inspection is recommended annually. Avoid installing the collector in shaded areas. The general recommended torque setting for nuts and bolts is 10Nm. A separate second array can be installed behind the first if necessary. Large arrays will require specialist piping, pump groups and design. The collector must not be installed on an uneven roof surface. Do not apply excessive force when installing the collector. Hot, exposed surfaces that can be touched must be insulated to protect against injury. Lubrication is not required for the ‘O’ ring connections. © Baxi Heating UK Ltd 2011 3 2.0 General Layout North Angle of tilt 90° 90° 80° 80° 70° 70° 60° 60° 50° 50° 40° 40° 30° 30° 20° 20° 10° 10° West East S.W. S.E. South less than optimum by 0-5% 5-10% 10-20% 20° to 55° 100mm > 350mm > 500mm > 500mm 4 © Baxi Heating UK Ltd 2011 3.0 Icon Quick Reference Guide 3A 3B 3C 13mm 3D 3E 3F 3G 3H 3J 3A - Contents 3B - Page Reference Number 3C - Measure 3D - Specialist Advice Required 3E - Materials to be Provided by Installer 3F - Spanner Tight 3G - Information or Advice 3H - Screwdriver 3J - Hammer 3K - 1 Collector 3L - 2 Collectors 3M - Right Hand Side 3N - Left Hand Side 3P - Caution 3Q - Drill / Driver 3R - Tile Cutter R/H 3K 3L L/H ! 3N 3P © Baxi Heating UK Ltd 2011 3M 3Q 3R 5 4.0 Dimensions a 174.5 174.5 SOL 200 SOL 200H SOL 250 SOL 250H 390 kg 0 b d c bar 10 ! 35kg 36kg 48kg 49kg 10bar 10bar 10bar 10bar 130 e f 150 / 300mm a 174.5 174.5 40 390 b c d f 130 e f a 174.5 40 40 174.5 390 b c 130 e f 6 © Baxi Heating UK Ltd 2011 d 4.0 Dimensions mm 1 2 3 4 5 mm Sol 200 Sol 200H Sol 250 Sol 250H Sol 200 Sol 200H Sol 250 Sol 250H a 1496 2101 1496 2536 a 7431 11067 7431 13671 b 1753 1147 2187 1147 b 1753 1147 2187 1147 c 1610 1004 2044 1004 c 1610 1004 2044 1004 d 2272 1666 2706 1666 d 2272 1666 2706 1666 e 1147 1753 1147 2187 e 7082 10718 7082 13322 6 f 1289 1895 1289 2329 f 7224 10860 7224 13464 a 2683 3895 2683 4763 a 8618 12860 8618 15898 b 1753 1147 2187 1147 b 1753 1147 2187 1147 c 1610 1004 2044 1004 c 1610 1004 2044 1004 d 2272 1666 2706 1666 d 2272 1666 2706 1666 e 2334 3546 2334 4414 e 8269 12511 8269 15549 7 f 2476 3688 2476 4556 f 8411 12653 8411 15691 a 3870 5688 3870 6990 a 9805 14653 9805 18125 b 1753 1147 2187 1147 b 1753 1147 2187 1147 c 1610 1004 2044 1004 c 1610 1004 2044 1004 d 2272 1666 2706 1666 d 2272 1666 2706 1666 e 3521 5339 3521 6641 e 9456 14304 9456 17776 8 f 3663 5481 3663 6783 f 9598 14446 9598 17918 a 5057 7481 5057 9217 a 10992 16446 10992 20352 b 1753 1147 2187 1147 b 1753 1147 2187 1147 c 1610 1004 2044 1004 c 1610 1004 2044 1004 d 2272 1666 2706 1666 e 4708 7132 4708 8868 9 d 2272 1666 2706 1666 e 10643 16097 10643 20003 f 4850 7274 4850 9010 f 10785 16239 10785 20145 a 6244 9274 6244 11444 a 12179 18239 12179 22579 b 1753 1147 2187 1147 b 1753 1147 2187 1147 c 1610 1004 2044 1004 c 1610 1004 2044 1004 d 2272 1666 2706 1666 e 5895 8925 5895 11095 f 6037 9067 6037 11237 © Baxi Heating UK Ltd 2011 10 d 2272 1666 2706 1666 e 11830 17890 11830 22230 f 11972 18032 11972 22372 7 ! 8 © Baxi Heating UK Ltd 2011 5.0 Health and Safety ! © Baxi Heating UK Ltd 2011 5.0 Health and Safety 9 ! 5.0 Health and Safety ! kg ! ! ! 10 © Baxi Heating UK Ltd 2011 6.0 Snow and Wind Load ! kg ! EN1991-1-3:2003 - Standard - Snow Loading SOL 200/200H/250/250H - Design limit snow load on the ground = 2.8kN/m2 ! X NOTE: This limit may be reduced for installations where abutments create additional risks of drifting or falling snow. EN1991-1-4:2005 - Standard - Wind Loading Y ! X - Basic wind speed (Vb, o) in m/s Y - Maximum height above ground for installation (m) WARNING: The maximum wind load to be borne by the mounting structure depends on the height and geographical area of the site among other factors. This structure must be installed in accordance with the provisions of the EN1991 standard. Consult a structural engineer if in doubt. Limit for in-roof installation for given site basic wind speed (For co=1) 200 SOL200/200H SOL250/250H 180 160 140 120 Y 100 80 60 40 20 0 21 22 23 24 25 26 27 28 29 30 31 32 33 X © Baxi Heating UK Ltd 2011 11 7.0 Optimum Pipework Assembly n<5 - Tee Piece SOL 200 - Valve SOL 250 - Plug - Air Vent (Optional) SOL 200H - Flow SOL 250H - Sensor n>5 SOL 200 SOL 250 SOL 200H SOL 250H 12 © Baxi Heating UK Ltd 2011 8.0 Kit Contents and Components BB3 JJ3 AA3 CC3 AA3 - Collector BB3 - Sensor Elbow CC3 - End Cap DD3 - Joining Piece EE3 - Elbow FF3 - Plug for Manual Air Vent GG3 - Tee Piece HH3 - Clip JJ3 - Manual Vent (Optional) KK3 - Auto Air Vent (Optional) LL3 - Sensor MM3 - 2m Pipe Kit NN3 - Straight Connector with fittings KK3 DD3 EE3 MM3 FF3 © Baxi Heating UK Ltd 2011 GG3 HH3 NN3 LL3 13 8.0 Kit Contents and Components AA BB CC RR SS WW XX VV UU TT YY DD NN KK LL SOL 250 only HA SOL 250 only JA PP JB HB JJ HH OO GG QQ 14 © Baxi Heating UK Ltd 2011 MM ZZ FF EE A - One SOL200 Portrait Collector Kit B - One SOL250 Portrait Collector Kit C - One SOL200H Landscape Collector Kit D - One SOL250H Landscape Collector Kit E - Two SOL200 Portrait Collector Kit F - Two SOL250 Portrait Collector Kit G - Two SOL200H Landscape Collector Kit H - Two SOL250H Landscape Collector Kit - Top Panel Landscape SOL200H J - SOL200 + 1 Extension Portrait Kit - Top Panel Landscape SOL250H K - SOL250 + 1 Extension Portrait Kit EE - Top Corner L/H L - SOL200H + 1 Extension Landscape Kit FF - Top Corner R/H M - SOL250H + 1 Extension Landscape Kit GG - Top Infill Section HH - Side Lower L/H Portrait SOL200 8.0 Kit Contents and Components +1 AA - Intermediate Clamp BB - Side Clamp CC - Bottom Bracket DD - Top Panel Portrait SOL200/250 - Side Lower L/H Landscape SOL200H/250H AA BB CC DD EE FF GG HH HA HB JJ JA JB KK LL MM NN OO PP QQ RR SS TT UU VV WW XX YY ZZ CC3 DD3 EE3 FF3 GG3 HH3 A 6 2 1 1 1 1 1 1 1 1 1 1 5 15 16 14 14 8 4 8 1 2 1 1 1 4 B 6 2 1 1 1 1 1 1 1 1 1 1 1 1 5 15 16 14 14 8 4 8 1 2 1 1 1 4 C 6 2 1 1 1 1 1 1 1 1 1 1 5 15 16 14 14 8 3 8 1 2 1 1 1 4 D 6 2 1 1 1 1 1 1 1 1 1 1 10 20 16 14 14 8 4 8 1 2 1 1 1 4 © Baxi Heating UK Ltd 2011 E 3 6 3 2 1 1 1 1 1 1 1 1 2 1 1 10 30 24 19 19 8 4 8 1 1 2 2 1 1 1 4 F 3 6 3 2 1 1 1 1 1 1 1 1 1 1 2 1 1 10 30 24 19 19 8 5 8 1 1 2 2 1 1 1 4 G 3 6 3 2 1 1 1 1 1 1 1 1 2 1 1 10 30 24 19 19 8 4 8 1 1 2 2 1 1 1 4 H 3 6 3 2 1 1 1 1 1 1 1 1 2 1 1 20 40 24 19 19 8 5 8 1 1 2 2 1 1 1 4 J 3 1 1 1 1 1 5 10 8 5 5 1 1 2 - K 3 1 1 1 1 1 5 10 8 5 5 1 1 2 - L 3 1 1 1 1 1 5 10 8 5 5 1 1 2 - M 3 1 1 1 1 1 10 20 8 5 5 2 1 2 - HA/HB - Side Lower L/H Portrait SOL250 JJ - Side Lower R/H Portrait SOL200 - Side Lower R/H Landscape SOL200H/250H JA/JB - Side Lower R/H Portrait SOL250 KK - Side Cover L/H Portrait SOL200 - Side Cover L/H Portrait SOL250 - Side Cover L/H Landscape SOL200H/250H LL - Side Cover R/H Portrait SOL200 - Side Cover R/H Portrait SOL250 - Side Cover R/H Landscape SOL200H/250H MM - Middle Infill Section Portrait SOL200 - Middle Infill Section Portrait SOL250 - Middle Infill Section Landscape SOL200H/250H NN - Bottom Section Portrait SOL200/250 - Bottom Section Landscape SOL200H - Bottom Section Landscape SOL250H OO - Bottom Corner L/H PP - Bottom Corner R/H QQ - Batten 25 x 75 x 1200 (mm) SOL200/250 - Batten 25 x 75 x 1800 (mm) SOL200H - Batten 25 x 75 x 2200 (mm) SOL250H RR - Wood Screw (75mm) SS - Wood Screw (25mm) TT - Coloured Waterproof Washer UU - Coloured Self Drilling Screw VV - Nail WW - Flashing Kit Foam (2m) XX - Side Flashing Fixing Tab YY - Instructions ZZ - Bottom Infill Piece 15 9.0 Installation of the Collector >a 6 7 >d RR X1 = Sol 200 Sol 250 Sol 200H Sol 250 H 435mm 560mm 260mm 260mm X2 = Sol 200 Sol 250 Sol 200H Sol 250 H 935mm 1185mm 585mm 585mm 85mm X3 = Sol 200 Sol 250 Sol 200H Sol 250 H 1435mm 1810mm 910mm 910mm QQ X4 X4 = Sol 200 Sol 250 Sol 200H Sol 250 H 2020mm 2460mm 1415mm 1415mm X3 X4 X2 X3 X2 85mm X1 QQ h 16 © Baxi Heating UK Ltd 2011 X1 >h h =h h >h = 9.0 Installation of the Collector 80mm X > 220mm W + 80mm SS W CC X QQ X= X CC Sol 200/250 1147mm Sol 200H 1753mm Sol 250H 2186mm CC CC CC CC © Baxi Heating UK Ltd 2011 17 SS 9.0 Installation of the Collector SS BB AA DD3 18 © Baxi Heating UK Ltd 2011 9.0 Installation of the Collector SS QQ SS AA BB3 BB LL3 QQ Seal using High Temperature UV Stable Sealant HH3 MM3 EE3 GG3 HH3 ! © Baxi Heating UK Ltd 2011 Seal using High Temperature UV Stable Sealant CC3 HH3 19 10.0 Fixing the Flashing OO TT UU NN ZZ PP TT UU TT UU HH MM HA HB 20 © Baxi Heating UK Ltd 2011 VV 10.0 Fixing the Flashing XX HH (HA) (HB) LL KK JJ (JA) (JB) TT © Baxi Heating UK Ltd 2011 UU 21 ! 10.0 Fixing the Flashing DD EE GG GG EE EE EE FF DD FF 22 © Baxi Heating UK Ltd 2011 GG 10.0 Fixing the Flashing TT - UU WW TT UU © Baxi Heating UK Ltd 2011 23 11.0 Maintenance It is recommended that the following checks are carried out on an annual basis: 1) Check the collector installation for any signs of damage or any build up of debris. 2) Check for any corrosion to the collector or the mounting system and repair if necessary. 3) Check the tightness of the fasteners. Where fasteners cannot be readily accessed, the overall security of the collector installation may indicate whether problems exist. 4) Check the fittings and pipe work for any signs of fluid leakage or damage, including the condition of the pipe insulation, and repair if necessary. Check inside the building for any evidence of leaks. 5) Examine the roof tiles around the collector installation for any damage or deterioration, and repair if necessary. 6) Check for any foliage growth that may cause shading of the collectors. 7) Where applicable, check the condition of any ballast used to secure the system. 8) In areas where there may be a build up of dirt on the collector, only non-abrasive cleaning materials and methods should be used to clean the collectors and mounting system components. All descriptions and illustrations provided in this leaflet have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. M U L T I F IT A Tr a din g D i v i s i o n o f B ax i H eat i ng U K Lt d ( 3879156) Brooks House, Coventry Road, Warwick. CV34 4LL Technical Enquiries 0844 871 1568 Website www.bdrthermea.com e&oe © Baxi Heating UK Ltd 2011 UK Comp No 720291002 (4/11)