Advanced Burner Control

7505

PARTS & ACCESSORIES

Product Description
The Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used
in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor,
igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power
stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time.

Features & Benefits
• Thermostat and boiler control compatible
• Customizable pre-time and post-time
• Three status lights for system monitoring and diagnostics
• Welded relay protection with redundant motor relays
• Limited reset and limited recycle
• Sleek, modern design
• Cad cell resistance indicator
• Technician Pump Prime mode
• 5-Year Warranty
• Two communication ports for adding alarm contacts, programming display,
and/or future wireless communications

Add a GeniSys Display and GeniSys Lockout Alarm
to fully utilize the features of the GeniSys advanced burner control.
The GeniSys Display (Pt. No. 52067) allows a technician to monitor and program the
primary control variables. The display shows current burner status, control timings, and
burner cycle history. The display’s programming mode allows a technician to customize both
the pre-time and post-time settings and a lockout service message.

• 32 character backlit alphanumeric display
• Sealed pushbutton keypad
• Low voltage operation
• Continuous real-time cycle monitoring
• Continuous cad cell resistance reading

• Customizable pre-time (valve-on delay) &
post-time (motor off delay)
• 15 cycle history monitoring
• Five Year Warranty
• Customizable lockout service message

• Continuous AC line voltage read-out
• Real-time error notification

The GeniSys Lockout Alarm (Pt. No. 52040) functions as the interface between the primary
control and an existing alarm panel or any alarm mechanism requiring contact closure in the
event of a soft or hard lockout of the GeniSys Control.

To learn more, see www.beckettcorp.com or ask for literature pt. nos. 61669 & 61687

R.W. Beckett Corporation
Mail: P.O. Box 1289, Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876) ● FAX: (440)327-1064

R.W. Beckett Canada Ltd.

Unit 3 - 430 Laird Road, Guelph, Ontario, Canada N1G 3X7 ● Phone: 800-665-6972 ● FAX: (519)763-5656

PARTS & ACCESSORIES

www.beckettcorp.com

Cross-Reference Chart
Beckett GeniSys
Control Part No.

Lockout
Time

Valve-on
delay time2

Motor-off
delay time2

Replaces
Honeywell:

Replaces
Carlin:

7505A 0000

15 sec

-

-

R7184A, R8184G

48245, 40200 42230, 502001

7505B 1500

15 sec

15 sec

-

R7184B

-

7505P 1515

15 sec

15 sec

15 sec

7505P 1530

15 sec

15 sec

7505P 152M

15 sec

15 sec

R7184P, R7184U

1

602001

30 sec

R7184P, R7184U

1

602001

2 min

R7184P, R7184U1

602001

1) Beckett snap-in alarm module required for direct replacement of the control. 2) Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-in programming display. Other factory set
timings are available. Contact Beckett for alternate timings.

Electrical Ratings
Inputs

Application Ratings

Voltage: 102 to 132 Vac
Current: 150 mA plus burner motor, igniter, and valve loads
Frequency: 60 Hz

Oil Burner Input: < 20gph
Control Programming: UL372 Group 2

Outputs
Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA)
Note – Reduce motor FLA rating by igniter current

Igniter: 120 Vac, 3 A @ 0.7 PF min
Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
Thermostat Anticipator Current: 0.1 A (If applicable)
Thermostat Voltage: 24 Vac (If applicable)

Environmental Ratings
Storage & Operating Ambient Temp.: -40°F to +150°F (-40°C to
+65°C)
Moisture: 5 to 95% RH, non-condensing and non-crystallizing

Approvals
Underwriters Laboratory Recognition per UL372 and UL1998,
and CSA C22.2 No. 199

Operation
Sequence of Operation

Resetting From Restricted Lockout
9

1
Standby

2

Valve-on
delay

3

5

8

Motor-off
delay

Trial for
ignition

Pump
prime

4

Lockout

Disable Function

Ignition
carryover
7

6

Run

If the control locks out three times without a satisfied call for
heat or fails the motor relay check, the Lockout becomes
restricted in order to prevent repetitious resetting by the
homeowner. To reset, hold the button down for 15 seconds
until the red light turns off and the yellow LED turns on.

Recycle

Any time the burner is running, press and hold the reset
button to disable the burner. The burner will remain off as
long as the button is held.

Priming The Pump

Cad Cell Resistance Indicator

1. Initiate a call for heat.

During the burner Run state, click the reset button to check
the cad cell flame resistance range. The yellow light will flash
1 to 4 times depending on the amount of light detected by the
cad cell. See the table below:

2. When the burner starts, press and hold the reset button for 15
seconds until the yellow light turns on.
3. Release the button. The yellow light will turn off and the burner
will start again.
4. At burner start up, click the reset button while the igniter is still on
to enter Pump Prime mode. The yellow light will turn on.
5. Bleed the pump until all froth and bubbles are purged.
6. If necessary, repeat steps 4 and 5 until the pump is fully primed
and the oil is free of bubbles.
7. When finished, hold the reset button or remove the call for heat to
exit Pump Prime mode and return to Standby.

Yellow LED Flashes

Cad Cell Resistance

1

Normal (0 - 400 ohms)

2

Normal (400 - 800 ohms)

3

Normal (800 - 1600 ohms)

4

Limited (1600 ohms - Lockout)

Form No. 61658 R08, Printed in the USA 04/08



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:64b6d0cd-7fba-4ca5-93a0-9766820cdc25
Producer                        : Acrobat Distiller 6.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2008:04:29 16:54:06-04:00
Create Date                     : 2008:04:29 16:54:06-04:00
Document ID                     : uuid:6093e827-0097-457b-9b6f-a24d30a9a255
Format                          : application/pdf
Title                           : 61658 Genisys Control Data R08.indd
Creator                         : amyers
Author                          : amyers
EXIF Metadata provided by EXIF.tools

Navigation menu