● Advanced Burner Control 7505 PARTS & ACCESSORIES Product Description The Beckett GeniSys™ Advanced Burner Control is a 120 Vac primary safety control for residential and light commercial oil burners used in boiler, furnace, and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 Vac thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15-second lockout time. Features & Benefits • Thermostat and boiler control compatible • Customizable pre-time and post-time • Three status lights for system monitoring and diagnostics • Welded relay protection with redundant motor relays • Limited reset and limited recycle • Sleek, modern design • Cad cell resistance indicator • Technician Pump Prime mode • 5-Year Warranty • Two communication ports for adding alarm contacts, programming display, and/or future wireless communications Add a GeniSys Display and GeniSys Lockout Alarm to fully utilize the features of the GeniSys advanced burner control. The GeniSys Display (Pt. No. 52067) allows a technician to monitor and program the primary control variables. The display shows current burner status, control timings, and burner cycle history. The display’s programming mode allows a technician to customize both the pre-time and post-time settings and a lockout service message. • 32 character backlit alphanumeric display • Sealed pushbutton keypad • Low voltage operation • Continuous real-time cycle monitoring • Continuous cad cell resistance reading • Customizable pre-time (valve-on delay) & post-time (motor off delay) • 15 cycle history monitoring • Five Year Warranty • Customizable lockout service message • Continuous AC line voltage read-out • Real-time error notification The GeniSys Lockout Alarm (Pt. No. 52040) functions as the interface between the primary control and an existing alarm panel or any alarm mechanism requiring contact closure in the event of a soft or hard lockout of the GeniSys Control. To learn more, see www.beckettcorp.com or ask for literature pt. nos. 61669 & 61687 R.W. Beckett Corporation Mail: P.O. Box 1289, Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876) ● FAX: (440)327-1064 R.W. Beckett Canada Ltd. Unit 3 - 430 Laird Road, Guelph, Ontario, Canada N1G 3X7 ● Phone: 800-665-6972 ● FAX: (519)763-5656 PARTS & ACCESSORIES www.beckettcorp.com Cross-Reference Chart Beckett GeniSys Control Part No. Lockout Time Valve-on delay time2 Motor-off delay time2 Replaces Honeywell: Replaces Carlin: 7505A 0000 15 sec - - R7184A, R8184G 48245, 40200 42230, 502001 7505B 1500 15 sec 15 sec - R7184B - 7505P 1515 15 sec 15 sec 15 sec 7505P 1530 15 sec 15 sec 7505P 152M 15 sec 15 sec R7184P, R7184U 1 602001 30 sec R7184P, R7184U 1 602001 2 min R7184P, R7184U1 602001 1) Beckett snap-in alarm module required for direct replacement of the control. 2) Valve-on delay and motor-off delay timings on all models are programmable with Beckett snap-in programming display. Other factory set timings are available. Contact Beckett for alternate timings. Electrical Ratings Inputs Application Ratings Voltage: 102 to 132 Vac Current: 150 mA plus burner motor, igniter, and valve loads Frequency: 60 Hz Oil Burner Input: < 20gph Control Programming: UL372 Group 2 Outputs Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA) Note – Reduce motor FLA rating by igniter current Igniter: 120 Vac, 3 A @ 0.7 PF min Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min Thermostat Anticipator Current: 0.1 A (If applicable) Thermostat Voltage: 24 Vac (If applicable) Environmental Ratings Storage & Operating Ambient Temp.: -40°F to +150°F (-40°C to +65°C) Moisture: 5 to 95% RH, non-condensing and non-crystallizing Approvals Underwriters Laboratory Recognition per UL372 and UL1998, and CSA C22.2 No. 199 Operation Sequence of Operation Resetting From Restricted Lockout 9 1 Standby 2 Valve-on delay 3 5 8 Motor-off delay Trial for ignition Pump prime 4 Lockout Disable Function Ignition carryover 7 6 Run If the control locks out three times without a satisfied call for heat or fails the motor relay check, the Lockout becomes restricted in order to prevent repetitious resetting by the homeowner. To reset, hold the button down for 15 seconds until the red light turns off and the yellow LED turns on. Recycle Any time the burner is running, press and hold the reset button to disable the burner. The burner will remain off as long as the button is held. Priming The Pump Cad Cell Resistance Indicator 1. Initiate a call for heat. During the burner Run state, click the reset button to check the cad cell flame resistance range. The yellow light will flash 1 to 4 times depending on the amount of light detected by the cad cell. See the table below: 2. When the burner starts, press and hold the reset button for 15 seconds until the yellow light turns on. 3. Release the button. The yellow light will turn off and the burner will start again. 4. At burner start up, click the reset button while the igniter is still on to enter Pump Prime mode. The yellow light will turn on. 5. Bleed the pump until all froth and bubbles are purged. 6. If necessary, repeat steps 4 and 5 until the pump is fully primed and the oil is free of bubbles. 7. When finished, hold the reset button or remove the call for heat to exit Pump Prime mode and return to Standby. Yellow LED Flashes Cad Cell Resistance 1 Normal (0 - 400 ohms) 2 Normal (400 - 800 ohms) 3 Normal (800 - 1600 ohms) 4 Limited (1600 ohms - Lockout) Form No. 61658 R08, Printed in the USA 04/08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:64b6d0cd-7fba-4ca5-93a0-9766820cdc25 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:04:29 16:54:06-04:00 Create Date : 2008:04:29 16:54:06-04:00 Document ID : uuid:6093e827-0097-457b-9b6f-a24d30a9a255 Format : application/pdf Title : 61658 Genisys Control Data R08.indd Creator : amyers Author : amyersEXIF Metadata provided by EXIF.tools