Beckman Coulter Biomedical B40421 B40421 RFID module User Manual B40420 B40421 RFID Modules
Beckman Coulter Biomedical GmbH B40421 RFID module B40420 B40421 RFID Modules
User Manual
Instructions for Use B40420 & B40421 RFID Modules B40420B40421 July 2015 Manufactured by Beckman Coulter, Inc. 250 S. Kraemer Blvd. Brea, CA 92821 U.S.A. Instructions for Use B40420 & B40421 RFID Modules PN B40420B40421 (July 2015) © 2015 Beckman Coulter, Inc. All Rights Reserved. Trademarks The following Beckman Coulter trademarks are registered in the USPTO and may be used in this manual: • Beckman Coulter and the Beckman Coulter logo All other trademarks are the property of their respective owners. Find us on the World Wide Web at: www.beckmancoulter.com EC REP Beckman Coulter Ireland, Inc. Mervue Business Park, Mervue Galway, Ireland 353 91 774068 Beckman Coulter do Brasil Com e Imp de Prod de Lab Ltda Calçada Aldebarã, 39, Centro De Apoio 2 - Alphaville, Cep 06541-055 - Santana De Parnaíba, Sp, Brasil CNPJ: 42.160.812/0001-44 製造販売業者: ベックマン・コールター株式会社 〒 135-0063 東京都江東区有明三丁目 5 番 7 号 TOC 有明ウエストタワー 贝克曼库尔特有限公司, 美国加利福尼亚州,Brea 市,S. Kraemer 大街 250 号, 邮编:92821 电话:(001) 714-993-5321 Beckman Coulter KK 贝克曼库尔特株式会社 东京都江东区有明三丁目 5 番 7 号 邮编:135-0063 Original Instructions Contents CHAPTER 1: Important User Information, 1-1 Prologue, 1-1 Important User Information, 1-1 Declaration of Conformity, 1-1 Comprehensive Integration Instructions, 1-2 Labeling of Host Equipment, 1-2 ESD Instructions, 1-3 Product Identification, 1-3 Product Information, 1-3 Intended Use, 1-3 Unintended Use, 1-4 Product Photos, 1-4 Physical Dimensions, 1-5 Electrical Interface, 1-5 Connector Type, 1-5 Connector Pin Allocation, 1-6 Technical Specifications, 1-6 Supported TAGs, 1-7 Communication Protocol, 1-7 Timing Diagram, 1-8 Port Settings, 1-8 Commands, 1-8 Firmware Update, 1-11 Contact, 1-11 B40420B40421 iii Contents iv B40420B40421 CHAPTER 1 Important User Information Prologue These Instructions For Use must be read prior to the installation and initial start-up of the RFID modules! It provides operating and maintenance instructions, commands, tag references, and other detailed product information like certification and conformity. Lire ce guide d'utilisation avant de procéder à l'installation et première mise en service du module RFID. Il fournit des instructions d'utilisation et de maintenance, des commandes, références de balises RFID et d'autres informations detaillées sur le produit tels que certification et conformité. Important User Information IMPORTANT: Changes or modifications to this product not authorized by Beckman Coulter Biomedical GmbH or improper use could void the Certification and negate your authority to operate this product. IMPORTANT: Les changements ou modifications à ce produit qui ne sont pas autorisés par Beckman Coulter Biomedical GmbH, ainsi que la mauvaise utilisation peuvent rendre invalide la certification et annuler votre autorisation d'opérer ce produit. Declaration of Conformity USA Information The following is communications regulation information on the RFID modules Model B40420 and B40421. FCC ID: 2AEGN-B40420 FCC ID: 2AEGN-B40421 This device complies with 47 CFR Part 15 Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. B40420B40421 1-1 Important User Information Comprehensive Integration Instructions Canada Information This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio RSS-210. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. IC: 20032 - B40420 IC: 20032 - B40421 Information These devices fully comply with R&TTE Directive 1999/5/EC. Comprehensive Integration Instructions For proper integration of modules in the final products it is required that following detailed and comprehensive instructions are followed by the integrators so that any subsequent associated party (grantee, host manufacture, original equipment manufacturer (OEM), integrator, or end-user) can clearly understand the conditions and limitations for authorized uses of the modular transmitter: • Do not exceed the DC power supply voltage of 5.5V. • The power supply has to be a SELV (Safety Extra Low Voltage) type compliant to EN 60950-1. • The DC power supply should have an output current limited to 500mA DC to avoid fire hazard in case of a short circuit into the module or cable. • Do not use the modules into an explosive ambient. • Do not use any liquids or solvents to clean the modules. • Follow the ESD instructions from this Manual. • Do not place any electrical conductive or ferromagnetic parts into a distance of 30mm from the PCB surface (measured perpendicular to it in both top and bottom direction) or 10mm coplanar with the PCB from any edge of the board, in order to avoid distorting the antenna characteristic. • Use only the protocol and commands described in this document to control the modules. Labeling of Host Equipment If the FCC / IC / CE identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label should contain the following, as applicable by model: 1-2 B40420B40421 Important User Information ESD Instructions US: Contains Transmitter Module FCC ID: 2AEGN-B40420, FCC ID: 2AEGN-B40421 Canada: Contains Transmitter Module IC: 20032-B40420, IC: 20032-B40421 Europe: ESD Instructions This equipment is sensitive to electrostatic discharge that can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static before handling the product. • Wear an approved grounding wrist strap or ESD clothes / shoes at a static-safe workstation if available. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment. • Store the equipment in appropriate static-safe packaging when not in use. Product Identification Model: B40420 multi antenna RFID Reader Model: B40421 single antenna RFID Reader Figure 1.1 Example Label Product Information This manual applies to B40420 and B40421 13.56 MHz RFID reader boards. Intended Use The modules should be used to read RFID Tags, under specific communication protocol, power supply, and environmental conditions in industrial environment, as a part of other equipment, machine or device. The modules are delivered without housing. Present manual should be read and followed by technicians, engineers and manufacturing personnel handling, building, installing, servicing or using the product. Violation of intended use may lead to loss of compliance certification. B40420B40421 1-3 Important User Information Product Information Unintended Use These modules are not designed and manufactured for use as standalone, or in any mobile, consumer, automotive or outdoor application. Any product change, modification, firmware update should only be carried out after prior approval of Beckman Coulter Biomedical GmbH. Product Photos Figure 1.2 B40420 Top View Figure 1.3 B40420 Bottom View Figure 1.4 B40421 Top View 1-4 B40420B40421 Important User Information Electrical Interface Figure 1.5 B40421 Bottom View Physical Dimensions Figure 1.6 B40420 PCB size: 662.5 x 63 mm, Cable length: 750 ±mm Figure 1.7 B40421 PCB size: 23 x 40 mm, Cable length: 750 ±mm Electrical Interface Connector Type Designation B40420B40421 Manufacturer Manufacturer's part no. RECEPTACLE, 8-POLE, MICRO-FIT 3.0 MOLEX 43025-0800 CRIMPCONTACT, FEMALE, AWG 24-20,MICRO-FIT 3.0 MOLEX 43030-0001 1-5 Important User Information Technical Specifications Connector Pin Allocation Pin # Wire color Signal WH/G GND OG RX A WH/BU TX Y GN +5VDC WH/OG RX B BU TX Z Technical Specifications Model no. B40420 Item Power supply Current consumption Specification +5V ± 10% Standby: 32mA Read: approx. 100mA 1-6 Communication interface 4 wire ANSI/TIA/EIA-485 Storage temperature -40°C ÷ 85°C Operating temperature 0°C ÷ 50°C Operating frequency 13.56 MHz TX power Max. 200mW Number of antennas 15, multiplexed Type of antenna PCB integrated Reading range 0 ÷ 30mm B40420B40421 Important User Information Supported TAGs Item Supported tags Specification ISO 15693 RFID tags Model no. B40421 Item Power supply Current consumption Specification +5V ± 10% Standby: 32mA Read: approx. 100mA Communication interface 4 wire ANSI/TIA/EIA-485 Storage temperature -40°C ÷ 85°C Operating temperature 0°C ÷ 50°C Operating frequency 13.56 MHz TX power Max. 200mW Number of antennas Type of antenna PCB integrated Reading range 0 ÷ 10mm Supported tags ISO 15693 RFID tags Supported TAGs • For B40420 Beckman order # B46145 TAG, RFID, 22mmx3mm - RCK • For B40421 Beckman order # B41938 TAG, RFID, 10mm x 2mm - TRAN Communication Protocol The RFID Boards communicate using a 4 wire ANSI/TIA/EIA-485 serial communication interface. The general structure of the communication is that the host sends a request to the RFID Board in a defined format. The RFID board then responds to the request in a defined time frame with a defined format. No spontaneous messages are sent by the RFID boards. The communication protocol is compatible to the ISO/IEC 13239 Standard. B40420B40421 1-7 Important User Information Communication Protocol Timing Diagram Description Symbol Time period before start of the request telegram tStart\End or after end of a response transmission, where no signal on the communication line is allowed. This is defined to ensure that no collision of transmitting happens. Time period for the request telegram to be send. Depends on the baud rate and data length. tReq Time period between request and response tGap Time period of the response length. Depends on the baud rate and data length. tResp Port Settings The default setting for the serial interface is: 57.6 kbps, 8N1. These values are fixed by firmware and cannot be changed by user. The default bus address for the RFID board is '0x01'. Commands Request Format General request format Start Flag Address Command Parameter Size Parameter CRC End Flag The definition for the fields is in the following table. Field name Size Start Flag 1 Byte Address 1 Byte Description Fixed value of '0x7F'. Address of the Client that has to respond to this request. 0x01 - 0xFE : Client Address Range 0xFF: Broadcast for all connected Clients 1-8 B40420B40421 Important User Information Communication Protocol Field name Size Description Command 1 Byte Command to execute from the Client. See Command Description Parameter Size 2 Bytes Amount of bytes used in the parameter section Parameter n Byte(s) Parameter bytes depending on the Command CRC 2 Bytes Checksum value CRC-16 (a.k.a. CRC-CCITT) as per definition in ISO/IEC 13239. See [3.1.1.7] for a detailed description End Flag 1 Byte Fixed value of '0xF7'. Response Format General response format Start Flag Address Command Data Size Data CRC End Flag The definition for the fields is in the following table. Field name Size Start Flag 1 Byte Address 1 Byte Description Fixed value of '0x80'. Address of the Client that responds to the host's request. 0x00 - 0xFE : Client Address Range Command 1 Byte Command that has been executed and that the client is responding to Data Size 2 Bytes Amount of bytes used in the Return section Data n Byte(s) Data bytes depending on the Command. Contains the Return Code. CRC 2 Bytes Checksum value CRC-16 (a.k.a. CRC-CCITT) as per definition in ISO/IEC 13239. End Flag 1 Byte Fixed value of '0xF8'. The RFID boards Serial Communication Interface supports the following (request and response) commands: • Initialization — Purpose: Initialize the hardware and firmware of the client. — Command Code: 0x01 — Format: Return Code / Board ID / Firmware Version Major / Firmware Version Minor — Input: NA — Output: RFID Board ID, Firmware Version • Set Communication Parameters — Purpose: Sets the communication parameters for the serial communication port. B40420B40421 1-9 Important User Information Communication Protocol — Command Code: 0x08 — Input: Bit rate, Data Bits, Parity bits, Stop bits. The Default values for the communication parameters are 57.6 kbps, 1 start bit, 8 bits data, 1 stop bit and no parity bit (8N1). — Output: NA • Start Firmware Update — Purpose: Sets the RFID reader board to the firmware update mode. — Command Code: 0x0A — Input: NA — Output: NA • Firmware Data — Purpose: Send the firmware data from the host to the RFID reader board. — Command Code: 0x0B — Input: Firmware HEX file — Output: NA • Set Address — Purpose: Sets the RS-485 Bus Address for the RFID reader board. — Command Code: 0x0F — Input: RS-485 Bus Address — Output: NA • Reset Address — Purpose: Reset the RS-485 Bus Address of the RFID reader board to the Default value. — Command Code: 0xFF — Input: NA — Output: NA • Get antenna connection state — Purpose: Identify the connected antennas and to know how many are connected to the RFID Board. — Command Code: 0x10 — Input: NA — Output: Amount of connected antennas and Antenna indices • Get inventory — Purpose: Read out the inventory from all RFID tag's that are in the range of the connected antennas. — Command Code: 0x11 — Input: NA — Output: Amount of connected antennas, Antenna indices, DSFID, UID • Get memory — Purpose: Read out the RFID Memory Data of all known RFID tag's or only one defined RFID tag. — Command Code: 0x1F — Input: RFID Tag — Output: Number of RFID Tags, Index of the antenna, Amount of data bytes for each RFID tags and Memory data 1-10 B40420B40421 Important User Information Contact Firmware Update The firmware is preprogrammed during manufacturing. The boards have both the option to firmware update in field (in installed and powered state) during serial communication interface, according to following procedure. • Send / respond the following commands — Initiation, Get Inventory for ensuring the RFID Reader Board is working fine — Set the new baud rate (For example: 115000-8-Even-1) : 0x01 • Communication settings are changed and updated in the Application code execution • Then send / respond the following commands • • • • — Initiation, Get Inventory for ensuring the RFID Reader Board is working fine with new baud rate — Start firmware upgrade and Firmware Data - to upgrade the new firmware command and write the new .hex file data to the flash (hex file available from Beckman Coulter) Firmware upgrade command is issued firmware will jump to boot Boot loader will receive new firmware data with changed communication settings But after successful programming of new application hex file, the RFID board will communicate with default communication settings (57600-8-None-1). RFID board needs power cycle after successful firmware upgrade process. Contact Beckman Coulter Biomedical GmbH Sauerbruchstrasse 50 81377 Munich, Germany Tel: +49 (0) 89 579589-0 www.beckmancoulter.com B40420B40421 1-11 Important User Information Contact 1-12 B40420B40421 www.beckmancoulter.com © 2015 Beckman Coulter, Inc. All Rights Reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Language : EN XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2015:07:20 00:54:13-08:00 Creator Tool : AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Modify Date : 2015:07:20 09:57:34+02:00 Metadata Date : 2015:07:20 09:57:34+02:00 Producer : Antenna House PDF Output Library 2.6.0 (Windows (x64)) Trapped : False Format : application/pdf Title : B40420 & B40421 RFID Modules Creator : Beckman Coulter Document ID : uuid:57dafe0c-fdbb-4f15-ac2a-90fbac6f4333 Instance ID : uuid:5419869b-d13a-4569-9349-e5d9be8ef41f Page Layout : SinglePage Page Mode : UseOutlines Page Count : 18 Author : Beckman Coulter Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools