Beijing GODA Instruments GDRD5Y6YA Pulse Radar Level Instrument User Manual FCC version11 19 for 209
Beijing GODA Instruments Co., LTD. Pulse Radar Level Instrument FCC version11 19 for 209
User Manual
Level Measurement Expert Pulse Radar Level Instrument Beijing GODA Instruments Co.,Ltd. 北京古大仪表有限公司 Table of Contents 1 For your safety...... ............... 2 Measurement Principle . ............... 3 Product Overview.................... 4 Mounting Requirement................. . ...1 ...2 ....3 ...7 5 Electrical Connection.................. . . . 1 3 6 Adjustment Instructions................. . .15 7 Dimensional Drawings.................. ..18 8 Technical Specifications................. . . 2 2 9 Selection & Ordering Information........... . 2 7 10 Application Questionnaire . ........... . .. 3 3 1. For your safety Authorised personal All operations described in this operating instructions manual must be carried out ouly by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn. Appropriate use Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions. FCC Certification This device complied with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Warning: User must keep a safety distance of at least 20cm from the antenna. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. 2 . Measurement Principle Principle The extremely narrow microwave pulse emitted by the antenna on radar level instrument can travel at the speed of light and part of its energy, which is reflected off the surface of target medium, is received by the very same antenna. The time lapse between pulse emission and reception by the antenna is proportional to the distance between the surface of target medium and the reference point on antenna. However, due to the fact that the electromagnetic wave is transmitted at extremely high speed, which leads to the tiny time lapse (nanosecond level) and makes it difficult to be identified, GDRD series of radar level instrument have adopted a special demodulation technology, enabling itself to detect the time lapse between pulse emission and reception correctly, and eventually generate accurate measurement result. Features The pulse radar level instrument, adopted K band range as transmission frequency, which make this series have specialties as below: Small beam angle, which centralize energy, make GDRD high ability of anti-jamming, hence high accuracy and reliable. Small antenna size, easy to mount and easy to equip extra dust protection. Small blind zone, good accuracy e v e n f o r s m a l l v e s s e l s . S h o r t e r w a v e - l e n g t h , s u i t a b l e f o r s m a l l p o w e r. Equipped with advanced microprocessor and unique EchoDiscovery echo processing technology, the radar level instrument can be used under various hazardous process conditions The pulse radar level instrument, with pulses as its working tool and extremely low emission power, can be mounted on various metal or nonmetal vessels, harmless towards the environment and human beings. 3 Product Overview GDRD55 GDRD61 Liquid Application: Max Measurement Range:: Measurement Accuracy: Common ±3mm 30m Enhanced 70m ±10mm Liquid Level measurement in liquids, especially highly erosive liquids 10m ±5mm Process Temperature: (-40~100) o C (-40~130)o C Process Pressure: Ordinary pressure (-0.1~0.3)MPa Signal Output: Power: (4~20) mA/HART 2-wire(DC24V) Display module: None Housing: Pa66 Process Connection: Lifting frame or 1’NPT (4~20)mA/HART 2-wire(DC24V) Flange Accessories: Antenna: GDRD57 GDRD56 Liquid Level measurement in liquids, under certain temperature and pressure, mildly erosive liquids 30m ±3mm (-40~80)o C (-40~130)o C (-60~250)o C (-60~400)o C Normal (-0.1~4)MPa (-0.1~40)MPa Liquid Level measurement of highly erosive medium under certain pressure/ temperature limit and suitable for 20m ±3mm (-40~150)o C (-0.1~0.5)MPa (4~20)mA/HART 2-wire(DC24V) (4~20)mA/HART 2-wire(DC24V) Optional Optional H/I/J/K L/M/P T/V Pulse Radar Level Instrument GDRD59 GDRD58 Solid strong dew/dust/crystal Solid Normal Temperature/Normal Pressure 70m ±15mm 15m ±10mm (-40~80)o C (-40~120)o C (-60~250)o C (-60~400)o C Normal (-0.1~4)MPa (-0.1~40)MPa (-40~80)o C Normal (4~20)mA/HART 2-wire(DC24V) (4~20)mA/HART 2-wire(DC24V) Optional Optional H/I/J/K L/M/P L/M/N T/V Housing Serial number Aluminium Material Specialty Process Connection Serial number Material PFA Stainless Steel Stainless Steel\\ (Huff) Pressure (-0.1~0.3)MPa (-0.1~4)MPa (-0.1~0.5)MPa (-40~130)oC Temperature (-60~150)oC Stainless Steel (-60~130)oC Stainless Steel Flange (-0.1~4)MPa (-0.1~40)MPa (-60~250)oC (-60~400)oC Flange Accessories Serial number (PTFE/PP)Flange Material Specialty Rust tolerated Stainless Steel Flange Stainless Steel Gimbal Flange High temp./High Pressure High temp./Normal Pressure Antenna Serial number Material Specification Specialty Φ44/Length86 Φ44/Length108 Stainless steel Φ48/Length140 Φ78/Length227 Φ98/Length288 Φ123/Length620 PFA Dn80 DN100 Normal Temperature Temperature tolerated/ Rust tolerated/ Pressure tolerated Pressure tolerated Stainless steel(PFA shield) Φ98/300 Φ123/625 Normal Temperature/ Normal Pressure Stainless steel Φ198 Φ246 Temperature tolerated/ Pressure tolerated Pulse Radar Level Instrument 4 . Mounting Requirements Basic Requirements There is a certain existing beam angle while the antenna transmitting microwave pulses. There should be no barriers between the lower edge of antenna and surface of measured medium. Therefore it is highly recommended to avoid facilities inside vessels, such asladders, limit switches, heating spirals, struts and etc, during the mounting process. “False echo learning” must be carried out during the installation in this case. Furthermore, microwave beams must NOT intersect the filling streams. Be cautions during the installation: the highest level of target medium must NOT enter into blanking zone; the instrument must keep certain distance to vessel walls; every possible measure needs to be taken to position the instrument so that the direction of antenna emission is perpendicular to the surface of measured medium. The installation of instruments in explosion proof area must abide by relevant local or federal safety regulations. Stainless steel housing should be used for intrinsically safe explosion proof version, which is also applicable in explosion proof areas. The instrument must be connected with ground in this case. Illustrations 43 The reference plane is the thread or flange surface 100% 1. Blanking Zone(menu1.9) 2. Empty(menu1.8) 3. Max. Adjustment(menu1.2) 4. Min. Adjustment(menu1.1) 0% Note:The highest level of measured medium must not enter into vlanking zone while radar level measurement instrument is in operation. Mounting Position >200mm Minium distance of 500mm between instrument and vessel wall during installation 1.Reference Plane 2.Center of Vessel or Symmetrical Axis 2 1.Reference Plane 2.Center of Vessel or Symmetrical Axis >200mm The best mounting position for a conical vessel with flat top is the center of its top, as the effective measurement can reach the bottom of vessel. Installation with Gimbal Pulse Radar Level Instrument Damp-proof In order to avoid dampness under outdoor or humid indoor conditions or for those instruments mounted on cooling/heating vessels, seal rings used on cables should be screwed tight, plus the cable must be bended downward outside cable entry, indicated on the diagram below Antenna Extension >10mm The transducer end must at least protrude 10mm out of socket. GDRD56 Antenna Extension If the senser is mounted in a socket extension that is too long, strong false echoes are generated which enterfere with the measurement. Make sure that the horn antenna protrudes out of the socket piece. d 1½ " 50mm(2") 80mm(3") 100mm(4") 150mm(6") h m ax 2 00m m 2 50m m 3 00m m 5 00m m 8 00m m G D R D 5 7 E xtensio n p ipe de m n s t r a t i on d 50mm(2") 80mm(3") 100mm(4") h max 100mm 150mm 250mm Rights and Wrongs in Mounting A大 约 1 3 D 10 1.Correct 2.Wrong:Instruments are mounted in the center of concave or arched vassel tops, which results in multiple echoes. 1.Wrong: Mount the instrument in/above filling stream, which results in the measurement of filling stream not the target medium. 2.Correct: Pulse Radar Level Instrument Reflection board installation If there are barriers in vessels, it is required to mount baffle-board, by doing this, the echo reflected by the barrier will be reflected out. And “False Echo Storage” will be applied. Agitator If there are agitators in vessels, instrument must be mounted as far away from agitators as possible. Once installation completed, a "false echo learning" should be carried out while agitators in motion to eliminate negative influence caused by false echo of agitators. You are advised to opt for installation with standpipe if foam or wave is generated due to the action of agitators. 11 Installation with Standpipe By using standpipe, the influence of foams can be reduced. Side through Standpipe installation with Standpipe ventilation hole You are advised to opt for installation with standpipe (or bypass tube) to avoid the influence on measurement caused by barriers inside vessels or foam generation. It is advised to install antenna inside of the standpipe to avoid the error caused by foam. The minimum inner diameter of standpipe should be 50mm. Avoid large cracks or welding seam when connecting standpipe. False echo storage must be carried out as well in this case. Note: You must NOT mount instrument inside standpipe while measuring adhesive medium. 12 Pulse Radar Level Instrument 5 Electrical Connection Power Supply 20mA/HART(2-Wire) Power supply and current signal are carried by the same two-wire connection cable. This equipment is not allowed to be connected to public utility power lines. See the Technical Specifications of this guide for detailed requirement on power supply. A safety barrier should be placed between power supply and instrument for intrinsically safe version. See the Technical Specifications of this guide for detailed requirement on power supply. Earth-connected current output can be used for standard version of level instruments, while the explosion proof version must be operated with a floating current output. Both instruments and earth terminals should be connected with ground firmly and securely. Normally you can either choose to connect with the earth terminal on vessel or adjacent ground in case of plastic vessels. Cable Connection General Introduction Standard 2-wire cable with outside diameter of 5...9mm, which assures the seal effect of cable entry, can be used as feeder cable. You are recommended to use screened Shielding & Grounding The two ends of shielded cable must be connected with earth terminal. The shielded cable must be connected with inner earth terminal directly inside the transducer, while the outside earth terminal on housing must be connected with ground. In the event of earth-connected current, the shielding side of shielded cable must be connected to ground potential via a ceramic capacitor (e.g. : 1μF 1500V) in order to dampen the low frequency grounding current and avoid the disturbance caused by high frequency signals Wiring Diagram 2-wire 2-wire wiring used for HART 1)Power Supply and Signal Output 13 Pulse Radar Level Instrument Explosion Proof Connection This product is an intrinsic safety explosion proof version (Exia ⅡC T6 Ga) with stainless steel housing and plastic-encapsulated internal structure aimed to prevent sparks resulted from transducer and circuit malfunction from leaking out. It is applicable for the non-contact continuous level measurement of flammable medium under the level of explosion proof inferior to Exia ⅡC T6 Ga. You are required to use series (intrinsic safety explosion proof: [Exia] ⅡC,voltage of power supply: 24V DC±10%,short-circuit current: 114mA,operating current: 4...20mA) of safety barriers, which are supplementary to this product, for the power supply of this product. All connection cables must be screened with max. length of 500m. Stray capacitor≤0.1μF/Km,stray inductance ≤1mH/Km. The level measurement instrument must be connected to ground potential and unapproved supplementary devices are not allowed to use. FBS-2 1 2 3 None-Explosion-Proof Zone 4 5 6 Explosion Proof Zone (4~20)mA (4~20)mA IN (4~20)mA OUT 24V OUT 24V IN 1 2 3 4 5 6 choose either one CO MW AY Adjust with GODAware 14 GODAware 6 Adjustment Instructions Adjustment Methods Three adjustment methods available for GDRD series : 1.Display/Adjustment Module 2.Adjustment software GODAware 3.HART handheld programmer ViewPoint is a pluggable display/adjustment module. The adjustment can be done through operating with four buttons on ViewPoint. Optional menu operation languages are available for selection. ViewPoint is only used for display after adjustment in that the measurement results can be seen clearly through the glass window. Display/Adjustment Module dB 12 0 11 0 10 0 90 80 70 60 50 40 30 20 10 0 . 00 2. 0 0 3.0 0 4 . 00 5 .0 0 LCD Adjustment Keypad [ O K ]Keypad -Enter programming mode; -Confirm programming options; -Confirm modifications to parameters. ]Keypad -Choose programming options; -Choose the digit of parameters to edit; -Display the contents of parameters. ]Keypad -Modify parameter values. [ B K ]Keypad -Programming mode exit; -Return to higher menu level. Shortcut [ B K ]Display Echo wave 15 Pulse Radar Level Instrument GODAware Connect with another unit throuth HART . - DC Choost Either One GODAware C O M WAY 1 RS232 Connect Cable/USB port GDRD series HATR pont adapter used on COMWAY convertor 250 ohm Resistance COMWAY Convertor Connect with another unit throuth I 2C . GODAware COMW A Y - DC 1 RS232 Connect Cable/USB port 2 GDRD series 3 I2C adapter pont used on MOMWAY convertor 4 COMWAY Convertor 16 HART Handheld Programmer Adjust GDRD series with HART Handheld Programmer - DC Choost Either One 1 HART Handheld Programmer 2 GDRD series 3 250 ohm Resistance 17 Pulse Radar Level Instrument 7 Dimension(Unit:mm) Housing Material: AL/PBT/ 316L GDRD61 Nylon Sheath 1 Sealing Hose 2 Sealing Flat Gasket 3 Upper Cover 4 Note: To install from 4 to 1. To remove from 1 to 4. 22 337.5 GDR D55 Threaded Vision 86.0 44 G112A(112NPT) 18 G DRD 56 Threaded Vision Huff Φ48 Φ78 Φ98 Φ123 H(316L) H(316L Shiele) 140 227 288 300 620 625 G DRD 57 Flange Version DN80 PN1.6 Φ200 Φ160 Φ132 174 DN100 PN1.6 Φ220 Φ180 Φ156 260 GDRD58 Threaded Vision Huff Φ48 Φ78 Φ98 Φ123 H(316L) H(316LShiele) 140 227 288 620 300 625 19 Pulse Radar Level Instrument GDRD58 Gimbal Flange Huff n×d n×d H1(316L) H1(316L Shield) 140 227 288 300 620 625 H1 H1 Φ48 Φ78 Φ98 Φ123 DN 100/4" 220mm 180mm 11.5mm 8xΦ18mm DN 125/5" 250mm 210mm 11.5mm 8xΦ18mm GDRD58/59 Threaded Vision 20 GDRD58/59 Gimbal Flange 10mm 4×φ18mm 10mm 4×φ18mm 10mm 4×φ22mm 10mm 4×φ22mm 10mm 4×φ26mm 21 Pulse Radar Level Instrument 8 Technical Specifications General Parameters series/Type Process Connection Material GDRD55 GDRD56 ThreadG1½A Thread1½NPT PP/PFA GDRD57 ThreadG1½A Thread1½NPT Flange 316L Stainless Steel 316L PFA PFA GDRD58 GDRD59 GDRD61 ThreadG1½A ThreadG1½A Lifting Frame Flange 316L Flange 316L Thread 1"NPT Thread1½NPT Thread1½NPT Stainless Steel316L PFA Stainless Steel316L PFA Aluminum PP Housing Aluminium,Stainless Steel 316L Seal ring between housing and housing cover Silicone ViewPoint window on housing Polycarbonate Ground terminal Stainless Steel Weight Weight -GDRD61 -GDRD55 -GDRD56 -GDRD57 -GDRD58 -GDRD59 1.6kg 1kg(Depend on process connections and housings) 2kg(Depend on process connections and housings) 3kg(Depend on process connections and housings) 7kg(Depend on process connections and housings) 2kg(Depend on process connections and housings) Power Standard Version Power Consumption Ripple Allowed (21.6~26.4)V DC max.22.5mA -<100Hz -(100~100K)Hz Uss<1V 2-wire Parameters on Cable Cable Entry/Plug Spring Connection Terminal Output Output Signal Resolution Fault Signal -2-wire load resistance Integration Time 22 Uss<10mV One cable entry of M20x1.5(cable diameter of 5~9m), one binding of M20x1.5 Applicable for cables with cross section of 2.5mm2 4...20mA/HART 1.6μA Constant current output: 20.5mA; 22mA;3.9mA See diagram below 0...40sec, adjustable Characteristic parameter Blanking Distance Max Measurement Distance End of Antenna -GDRD55 -GDRD56 -GDRD57 -GDRD58 -GDRD59 -GDRD61/61L Measurement Interval Adjustment Time 10m(liquid) 30m(liquid) 20m(liquid) 70m (solid) 15m (solid) 30m/70m(liquid) About 1sec(Depend on parameter settings) About 1sec(Depend on parameter settings) Resolution of Display 1mm Accuracy See the diagram below Temperature for Storage/Transport (-40~100)oC Process Temperature (Probe) Relative Humidity Pressure Vibration Proof -GDRD55 -GDRD56 -GDRD57 -GDRD58 -GDRD59 -GDRD61 <95% Max.40MPa (-40~130)oC (-60~400)oC (-40~150)oC (-60~400)oC (-40~200)oC (-40~100)oC Mechanical vibration10m/s 10m2/s ,10~150Hz 23 Pulse Radar Level Instrument GDRD61 Accuracy See the diagram below 10mm 3mm 0.5m 30m -3mm -10mm GDRD55 Accuracy See the diagram left 10mm 5mm 0.5m 10m -5mm -10mm 1) The generation of accurate measurement results needs longer time than usual in the event of drastic level changes(mx. Error 10%). GDRD56 Accuracy See the accuracy illustration diagram below 10mm 3mm 0.5m - 3 mm - 1 0m m 24 30m GDRD57 Accuracy See the accuracy illustration diagram below 10mm 3mm 1.0m 20m -3mm -10mm GDRD58 Accuracy See the accuracy illustration diagram below 30mm 15mm 1.0m 70m - 1 5m m -30mm 25 GDRD59 Accuracy See the accuracy illustration diagram below 15mm 10mm 1.0m -10mm - 1 5m m 26 30m Pulse Radar Level Instrument 9 Selection & Ordering Information GDRD55 Explosion Proof Approval P Standard I Intrinsically Safe(Exia IIC T6 Ga) Shape of Antenna/Material B (R)Airproof HornΦ44mm/L86 N (R)Airproof HornΦ44mm/L108 Process Connection/Material GP (F)Thread G1½A NP (F)Thread 1½NPT Length of Vessel Socket A NO Electronic B (4~20)mA/HART2-Wire Housing/Protection A Aluminium/IP67 Cable Entry M M20x1.5 ½NPT Display/Programming A Yes X No 27 GDRD56 Explosion Proof Approval P Standard I Intrinsically Safe(Exia IIC T6 Ga) Shape of Antenna/Material (T)Horn (T)Horn (T)Horn (T)Horn (Z)Horn Φ48mm/L140/Stainless Steel 316L Φ78mm/L227/Stainless Steel 316L Φ98mm/L288/Stainless Steel 316L Φ123mm/L620/Stainless Steel 316L Φ78mm/Flexible/Stainless Steel 316L Process Connection/Material GP (H)thread G1½A/Stainless Steel 316L GA (H)thread 1½NPT/Stainless Steel 316L GB (G)thread G1½A/PP GC (J)thread G1½A/Stainless Steel 316L/temperature(-60~250)oC GE (I)thread G1½A/Stainless Steel 316L(Huff) Flange/Material Material Spec Code DN50 DN80 DN100 DN125 PP(L) FA GA HA IA PTFE(L) FB GB HB IB Stainless Steel(M) FC GC HC IC F0 No Seal/Process Temperature 2 Viton(-60~150)oC 3 Kalrez(-60~250)oC 4 Graphite(-60~400)oC Electronic B (4~20)mA/HART 2-Wire Housing/Protection A Aluminium/IP67 Cable Entry M M20x1.5 ½NPT Display/Programming A Yes X No 28 Pulse Radar Level Instrument GDRD57 Explosion Proof Approval P Explosion Proof Approval I Intrinsically Safe(Exia IIC T6 Ga) Shape of Antenna/Material C (U)Stainless Steel&PFA Flange DN80 D (U)Stainless Steel&PFA Flange Dn100 Electronic B (4~20)mA/HART 2-Wire Housing/Protection A Aluminium/IP67 Cable Entry M20x1.5 ½NPT Display/Programming A Yes X No 29 GDRD58 Explosion Proof Approval P Explosion Proof Approval I Intrinsically Safe(Exia IIC T6 Ga) Shape of Antenna/Material (T)Horn Φ78mm/L227/Stainless Steel316L (T)Horn Φ98mm/L288/Stainless Steel316L (T)Horn Φ123mm/L620/Stainless Steel316L (V)Horn Φ98mm/L300/Stainless Steel316L/PFA Shield (V)Horn Φ123mm/L625/Stainless Steel316L/PFA Shield (W)ParaboloidΦ198mm/Stainless Steel316L (W)ParaboloidΦ246mm/Stainless Steel316L (Z)Horn Φ78mm/Flexible/Stainless Steel316L Process Connection/Material GP (H) Thread G1½A/Stainless Steel316L GA (H) Thread 1½NPT/Stainless Steel316L GB (G) Thread G1½A/PP GC (J) Thread G1½A/Stainless Steel316L/ Temperature (-60~250)oC GE (I) Thread G1½A/Stainless Steel316L(Huff) GF (E) Thread G1½A/Stainless Steel316L/Temperature (-60~250)oC Flange/Material Material Spec Code DN50 DN80 DN100 DN125 PP(L) PTFE(L) Stainless Steel(M)Gimbal Flange(PP)(N)Gimbal Flange(Stainless Steel)(P) FA GA HA IA FB GB HB IB FC GC HC IC HD ID F0 No Seal/Process Temperature 2 Viton(-60~150)oC 3 Kalrez(-60~250)oC 4 Graphite(-60~400)oC Electronic B (4~20)mA/HART 2-Wire Housing/Protection A Aluminium/IP67 Cable Entry M M20x1.5 ½NPT Display/Programming A Yes X No 30 HE IE Pulse Radar Level Instrument GDRD59 Explosion Proof Approval P Explosion Proof Approval I Intrinsically Safe(Exia IIC T6 Ga) Shape of Antenna/Material (T)Horn Φ78mm/L227/Stainless Steel316L (T)Horn Φ98mm/288/Stainless Steel316L (T)Horn Φ123mm/L620/Stainless Steel316L (V)Horn Φ98mm/L300/Stainless Steel316L/PFA Shield (V)Horn Φ123mm/L625/Stainless Steel316L/PFA Shield (W)Parabolic Φ198mm/Stainless Steel316L (W)Parabolic Φ246mm/Stainless Steel316L (Z)Horn Φ78mm/Flexible Process Connection/Material GP (H) Thread G1½A/Stainless Steel316L GA (H) Thread 1½NPT/Stainless Steel316L GB (G)thread G1½A/PP GE (I) Thread G1½A/Stainless Steel316L(Huff) GF (E) Thread G1½A/Stainless Steel316L/Temperature (-60~250)oC Flange/Material Material Spec Code DN50 DN80 DN100 DN125 DN150 DN200 DN250 PP(L) FA GA HA IA JA KA LA PTFE(L) Stainless Steel(M) FB GB HB IB JB KB LB FC GC HC IC JC KC LC Gimbal Flange(Stainless Steel)(P) HE IE JE KE LE F0 No Seal/Process Temperature 2 Viton(-60~80)oC 3 Kalrez(-60~250) C Electronic B (4~20)mA/HART 2-Wire Housing/Protection A Aluminium/IP67 Cable Entry M20x1.5 ½NPT Display/Programming A Yes X No 31 GDRD61 Explosion Proof Approval Standard(max measurement range of 30m) Intrinsically Safe Exia IIC T6 Ga Enhanced(max measurement range of 70m) Shape of Antenna/Material Horn Φ78mm/L221/PA66 Process Connection/Material GB THREAD 1″NPT PP GD LIFTING FRAME Electronic (4~20)MA/HART Housing/Protection IP68 Programming A Yes No Sunshield A Yes X No Cable A Standard twin-core shielded (leagth of 10m) B Length of twin-core shielded(length:X m) C Length of 7-core shielded lead(length:X m) 32 Pulse Radar Level Instrument 10 Application Questionnaire Approvals Standard Version Intrinsically Safe Version(Exia IIB T6 Ga) Intrinsically Safe Version(Exia IIC T6 Ga) Intrinsically Safe Version+Explosion Proof(Exdia [ia Ga] IIC T6 Gb) Measured Medium Name Condition Liquid Temperature: Min. Surface Flat Dielectric Constant Solid Form Mass Norm. ° Turbulent εr<3 εr>3 Particle Max. ° Agitated Dust) °C Vorte Atmosphere Atmosphere Form Atmosphere Pressure Foam Dust Min. Deposit Norm. Vapour Max. Vessel Shape of Top Flat Height Critical Information Arch Conical Horizontal Diameter Nozzle Length: Nozzle Diameter: Measurement Range: Process Connection Thread( G3/4 A NPT G1A ) Swivelling Holder 3/4 Flange(DN= G 1 A、M 1 0 5 x 2 G1½A 1 ½ N PT G2A ) Installation Mode: Top Side Filling Stream inlet position and installation position (Please specify in the diagram below) Circular Vessel Square Vessel Communication ( 4~20) mA/ HART Display Yes No Customer Information Please give brief explanation on the application of instrument: Contact: Company: Address: P. C.: Email: Tel: Fax: Date: 33 Beijing GODA Instruments Co.,Ltd. Beijing GODA Instruments Co., Ltd. Add: Management Address:3RD Floor,Block B, Hongxianhong base,Beiqijia Town,Changping District,Beijing. Tel:(010)89759341 89759342 89759343 Fax:(010)89759327 PC: 102209 Website: www.godacn.com 89759344 Email:sales@godacn.com Sales Dept Of Beijing GODA Instruments Co., Ltd. Add: Room1303, Block D, Ocean International Center, No 62 Middle Of east 4th ring, Chaoyang Dist., Beijing,100025, China Tel:(010)59648788(Ext.8) Fax:(010)59648789 PC: 100025 Edition: GD/200902
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 36 Create Date : D:20141119164221 Modify Date : D:20141119164221 Producer : Corel PDF Engine Version 1.0.0.458 Creator : CorelDRAW 版本 12.0 Title : FCC version11_19 for 209EXIF Metadata provided by EXIF.tools