Belter Health Measurement and Analysis Technology E656 Bluetooth wi-fi smart health scale User Manual koogeek S1

Shenzhen Belter Health Measurement and Analysis Technology Co., Ltd. Bluetooth wi-fi smart health scale koogeek S1

User manual-koogeek-S1

Download: Belter Health Measurement and Analysis Technology E656 Bluetooth wi-fi smart health scale User Manual  koogeek S1
Mirror Download [FCC.gov]Belter Health Measurement and Analysis Technology E656 Bluetooth wi-fi smart health scale User Manual  koogeek S1
Document ID2989752
Application IDPWxnasXmuH84vPXZ+jnnYQ==
Document DescriptionUser manual-koogeek-S1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.3kB (403799 bits)
Date Submitted2016-05-13 00:00:00
Date Available2016-10-23 00:00:00
Creation Date2016-05-09 17:46:04
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2016-05-09 17:46:04
Document TitleUser manual-koogeek-S1
Document CreatorMicrosoft® Office Word 2007
Document Author: 微软用户

Koogeek-S1
Function
View 8 Groups of Body Composition Data via the app.
Weight: Check your weight trends
Lean Mass %: Track muscle gain
Fat Mass%: Measure body fat percentage, track fat loss
BMI: Check your healthy range
Bone Mass %: Check your bone mass percentage
Body Water %: Check your body water percentage
BMR: Check your basal metabolic rate
Visceral Fat %: Check your visceral fat percentage
Warning
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities of lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and any understand
the hazards involved. Children shall not be play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
This product will send the measurement data only after the completion of the human body
measurement
How to use
1. Make sure the power supply is normal before using the smart health scale.
2. When a user stands barefoot on the smart health scale ( face the direction of smart health scale
display with each foot stepping on the ITO film of the smart health scale), once the body weight is
more than 5kg, the smart health scale will start measuring weight and body resistance and
display weight on the screen. The smart health scale will automatically turn off five seconds after
the user stepping off the scale.
3. When the smart health scale is on, switch weight unit (kg, lb, St) by pressing the Reset button
on the back of the scale .
4. When the smart health scale is off, press and hold the Reset button for 5 seconds or more, the
smart health scale enters configuration status, and then the user can bind smart health scale to the
app.
Specifications
Name: Bluetooth Wi-Fi Smart Scale
Model: Koogeek-S1
Users: Up to16 users
Measuring Range: 5kg-150kg
Function: Measuring weight, BMI, body fat, body water, lean mass, bone mass, visceral fat, BMR
Power Supply: 4 * AA Battery
Size: 315mm * 315mm * 29 mm
Weight: 2.5kg
Wireless: Bluetooth 4.0, Wi-Fi
Display Screen: LED (Blue)
Color: White
Supported System: Android, iOS
Compatible iOS devices: iOS 8.0 or above
Compatible Android devices: Android 4.3 or above
Operating Temperature: 0°C to 56°C
Relative Humidity: 0-95%
Material: ITO tempered glass + ABS
APP Introduction
1. APP Download Website:
www.koogeek.com
2. APP Installation: For Android mobile phones, please download the app through the official web
site, and install directly on the phone; For iOS mobile phones, please download through app store
and install the app.
3. APP Instructions
3.1 When installing the app for the first time, the user needs to register a new user account and log
in.
3.2 Choose the smart health scale in the device list on the app, when a user stands on the smart hea
lth scale, it can be connected via Bluetooth with the app on the smart phone and the app can get m
easuring results and calculate the eight groups of health data.
POWER
Battery: 4xAA batteries
SWITCH OFF OR AUTO OFF
1, After finish weighing or if no any operation of the scale, the scale will automatically
switch off after approximate 30 seconds.
LOW BATTERY INDICATOR
When the battery power is low, scale will display "Lo", please replace the battery in time.
ATTENTION
1, Place the scale on a hard and flat surface to ensure the greatest accuracy and
reliability.
2, Do not use any chemical cleanser to clean the scale. Clean your scale with a damp
cloth, but do not immerge your scale into any liquid, as this can damage the inner
parts.
3, To ensure that the scales of life, please do not over-heat scale placed in the
environment.
4, Remove the batteries if the scale is not being used for a long time.
5, Treat your scale with care. It’s a precision instrument, do not drop it or jump on it.
Don’t put the object over 150% of the max capacity on the plate.
6, If the scale doesn’t work, check whether the battery contact well with the contactor. If
the scale has been used for a long time, check whether the batteries need to be
replaced. If necessary, please contact the distributor or call our company.
7, This scale is only used in household for body weight measurement, not for
commercial or other use
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly approved
by the party responsible for compliance could void the user’s authority to operate
this equipment.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment and it also complies with Part 15 of FCC RF Rules.
CAUTION
To comply with the limits of the Class B digital device, pursuant to Part 15 of the
FCC Rules, this device is comply with Class B limits. All peripherals must be shielded
and grounded. Operation with non-certified peripherals or non-shielded cables may
results in interference to radio or reception.
MODIFICATION
Any changes or modifications not expressly approved by the grantee of this device
could void the user’s authority to operate the device.
Annex of Report
Manufacturer’s Declaration of the EUT
(altogether 5 pages)
Guidance and manufacturer’s declaration – electromagnetic emission –
for all EQUIPMENT AND SYSTEMS
Guidance and manufacturer’s declaration – electromagnetic emission
The SF-371 body fat scale is intended for use in the electromagnetic environment specified below. The
customer or the user of SF-371 body fat scale should assure that it is used in such an environment.
Emissions test
Compliance
RF emissions
Group 1
CISPR 11
Electromagnetic environment - guidance
The SF-371 body fat scale uses RF energy only for its internal
function. Therefore, its RF emissions are very low and are not
likely to cause any interference in nearby electronic equipment.
RF emissions
Class B
The SF-371 body fat scale is suitable for use in all
establishments, including domestic establishments and those
directly connected to the public low-voltage power supply netw
ork
that supplies buildings used for domestic purposes.
CISPR 11
Harmonic emissions
N/A
IEC 61000-3-2
Voltage fluctuations /
flicker emissions
N/A
IEC 61000-3-3
Guidance and manufacturer's declaration – electromagnetic immunity –
for all EQUIPMENT and SYSTEMS
Guidance and manufacturer’s declaration – electromagnetic immunity
The SF-371 body fat scale is intended for use in the electromagnetic environment specified below. The customer
or the user of the SF-371 body fat scale should assure that it is used in such an environment.
Immunity test
Electrostatic
discharge (ESD)
IEC 61000-4-2
Electrostatic
transient / burst
IEC 61000-4-4
IEC 60601
test level
Compliance level
± 6 kV contact
± 6 kV contact
± 8 kV air
± 8 kV air
± 2 kV for power
supply lines
N/A
± 1 kV for input/output
lines
Electromagnetic environment guidance
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative
humidity
should be at least 30 %.
Mains power quality should be that of
typical commercial or hospital
environment.
Surge
IEC 61000-4-5
± 1 kV differential
mode
N/A
± 2 kV common mode
< 5 % UT
(>95 % dip in UT )
for 0.5 cycle
Voltage
dips,
40 % UT
short
(60 % dip in UT )
interruptions and
for 5 cycles
voltage variations
on power supply
70 % UT
input lines
(30 % dip in UT )
for 25 cycles
IEC 61000-4-11
N/A
< 5 % UT
(>95 % dip in UT )
for 5 sec
Power frequency
(50/60 Hz)
magnetic field
IEC 61000-4-8
NOTE
3 A/m
3 A/m
Mains power quality should be that of
typical commercial or hospital
environment.
Mains power quality should be that of
typical commercial or hospital
environment. If the user of the
SF-371 body fat scale
requires
continued operation during power
mains
interruptions,
it
is
recommended that the SF-371 body
fat scale
be powered from an
uninterruptible power supply or a
battery.
Power frequency magnetic fields
should be at levels characteristic of a
typical location in a typical
commercial or hospital environment.
UT is the a. c. mains voltage prior to application of the test level.
Guidance and manufacturer’s declaration – electromagnetic immunity –
for EQUIPMENT and SYSTEM that are not LIFE-SUPPORTING
Guidance and manufacturer’s declaration – electromagnetic immunity
The SF-371 body fat scale is intended for use in the electromagnetic environment specified below. The customer or
the user of the SF-371 body fat scale should assure that it is used in such an environment.
Immunity test
IEC 60601 test
level
Compliance level
Electromagnetic environment - guidance
Portable and mobile RF communications equipment
should be used no closer to any part of the SF-371 body
fat scale , including cables, than the recommended
separation
distance
calculated
from
the
equation
applicable to the frequency of the transmitter.
Recommended separation distance
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF
N/A
3 V/m
d [
3.5
] P
V1
d [
3.5
] P
E1
d [
] P
E1
80 MHz to 800 MHz
800 MHz to 2.5 GHz
3 V/m
IEC 61000-4-3
80 MHz to 2.5 GHz
where p is the maximum output power rating of the
transmitter in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).b
Field strengths from fixed RF transmitters, as determined
by an electromagnetic site survey,a should be less than the
compliance level in each frequency range. b
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1
At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2
These guidelines may not apply in all situations. Electromagnetic is affected by absorption and reflection from structures,
objects and people.
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios,
amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the
electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field
strength in the location in which the SF-371 body fat scale
SF-371 body fat scale
is used exceeds the applicable RF compliance level above, the
should be observed to verify normal operation. If abnormal performance is observed, additional measures
may be necessary, such as reorienting or relocating the SF-371 body fat scale
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.
Recommended separation distances between portable and mobile
RF communications equipment and the EQUIPMENT or SYSTEM for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING
Recommended separation distances between
portable and mobile RF communications equipment and the SF-371 body fat scale
The SF-371 body fat scale
is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the SF-371 body fat scale
can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the SF-371 body
fat scale
as recommended below, according to the maximum output power of the communications equipment
Separation distance according to frequency of transmitter
Rated maximum
output of
transmitter
150 kHz to 80 MHz
d [
3.5
] P
V1
80 MHz to 800 MHz
d [
3.5
] P
E1
800 MHz to 2.5 GHz
d [
] P
E1
0.01
0.12
0.23
0.1
0.38
0.73
1.2
2.3
10
3.8
7.3
100
12
23
For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres
(m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output
power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 10
Language                        : en-US
Tagged PDF                      : Yes
Author                          : 微软用户
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2016:05:09 17:46:04+08:00
Modify Date                     : 2016:05:09 17:46:04+08:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AAEEE656

Navigation menu