Bioinsec CADENACIO FINGERPRINTER ACCESS CONTROLLER User Manual

Bioinsec Co.,Ltd FINGERPRINTER ACCESS CONTROLLER Users Manual

Users Manual

Download: Bioinsec CADENACIO FINGERPRINTER ACCESS CONTROLLER User Manual
Mirror Download [FCC.gov]Bioinsec CADENACIO FINGERPRINTER ACCESS CONTROLLER User Manual
Document ID1310463
Application ID1nIp/hz3Dnzj3jMJ64gqjA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize25.48kB (318544 bits)
Date Submitted2010-07-13 00:00:00
Date Available2011-01-09 00:00:00
Creation Date2017-11-08 21:47:59
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-11-08 21:47:59
Document TitleMicrosoft Word - Cadenacio Device Manual[ENG6.0].docx
Document CreatorPScript5.dll Version 5.2.2
Document Author: MYHOME

Cadenacio Device Manual
Ver 1.0
’02 Ace Techno Tower1, 1’”-24, Guro-3-dong, Guro-gu, Seoul, 152-‘4‘, Korea
Cadenacio device Manual
Content
1.
Product Instruction ...........................................................................................................- ③ 1-1 Product Specification ...............................................................................................- ④ 1-2 Product Feature........................................................................................................- 8 -
2.
The matters to be checked .............................................................................................- 10 2-1 Precaution / Emergency.........................................................................................- 10 2-2 Terminal Configuration ..........................................................................................- 12 2-3 Icon Guidance .........................................................................................................- 13 2-4 Screen Information & Voice Guidance ..................................................................- 15 2-5 The Proper Method For Registration And Input Of
Fingerprint ........................- 1③ -
3-1. Menu Setting .........................................................................................................- 1④ 3-2. The Organization Of Menu ....................................................................................- 20 3-3. Detail Menu Explanation .......................................................................................- 25 3.
Door Setup...............................................................................................................- 30 -

Configuration ...........................................................................................................- 30 -

Door.........................................................................................................................- 30 -
①
Reader(In) ............................................................................................................- 30 Input/Output.........................................................................................................- 30 Time Delay ..........................................................................................................- 30 -
⑤
Alarm ....................................................................................................................- 30 -
1 : OpenTooLongTime .....................................................................................................- 30 2 : OpenTooLong.............................................................................................................- 30 4.
System ....................................................................................................................- 31 -
www.bioinsec.com
-2-
Cadenacio device Manual
FCC Information to User
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution
Modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC Compliance Information : This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause undesired
operation
www.bioinsec.com
-3-
Cadenacio device Manual
Explanation for terms
฀ Master/Administrator
It refers to the master who can enter into menu mode of terminal. He has such
authorities to register/correct/delete users and also to change operation
environment by modifying installations.
User ID of master is 0 . When user set terminal at first time, he have to use 1111 as a
password. Master has to change this setting value or recognition method for fingerprint.
฀
1 to 1 Verification
It means the method of verifying the fingerprint after a user ID or card has been
entered.
As it compares the only fingerprints registered at the user ID or card, it is called 1
to 1 Verification.
฀
1 to N Identification
It refers to the method of identifying the user by using the fingerprints only.
As it is kind of method of identifying the same fingerprint as the one registered
without a user ID or card, it is called 1 to N Identification.
฀ Security Level
It is the grade used for the verification of fingerprint. Tune security level from Very
Low (1) to Very High (5) level. 3. Normal is set in default. The higher security
level is the lower FAR (fault acceptance rate). Reversibly the lower security level is
the higher FAR. There is an inverse proportion between FAR and FRR (fault
rejection rate).
฀ Authentication Method
It means various forms of verification combined with FP(fingerprint) verification,
PW(password) verification, RF(card) verification
Example) FP|PW: it verifies the person through password, when such verification
means as fingerprint and password fail.
www.bioinsec.com
-4-
Cadenacio device Manual
฀ Function Key
For using Time & Attendance mode, you can set. It refers to such keys as [F0], [F1],
[F2], [F3], [ENTER], and can change the verification into each verification mode.
฀
I/O MAN (Controller)
I/O Man is installed internal of office. And I/O Man communicates with encrypted
data with 4‘5 communication, control lock device and support various I/O ports.
฀ Access Sensor
It was built-in sensor of terminal. When someone approaches within 1m to
terminal, it makes the LCD turn the light on and the camera automatically work.
฀ LAN Card
It is built in module in the terminal. It absolutely needs to communication with
TCP/IP. If you want to use another communication like as RS232, 4‘5, Wiegand not
TCP/IP, you have to remove LAN card and exchange necessary communication
module.
฀ Flash Card
Flash card mounts 32Mbyte flash memory as a built-in module in the terminal. The
flash memory saves firmware and all data. When the firmware is broken and need
to update, you just replace it with new flash card.
฀ Key Phone Card (Option)
It mounts as a module in the terminal. This board is installed in the terminal and
connects switchboard. And then, it is possible to connect telephone through
pressing extension digit in the terminal. And you can call with internal staff. When
calling between visitor and staff, the staff can open the door with pressing
password with using dial-up button.
www.bioinsec.com
-5-
Cadenacio device Manual
1. Product Instruction
BKS-4‘00 device of Bioinsec company is fingerprint access control system which manages for
access controller, time & attendance, managing membership and student management to
check identification. This product can be used to identify each person with their fingerprint
and save image at the point of person s recognition shot. As a result, when using RF system
and keypad, it solves many problems which are for copied card, issuing same card and same
pin number. Fingerprint has a feature like as permanence and unique. Because it is costeffective device, it widely uses in the world. The optic sensor of BKS-4‘00 has developed by
Bioinsec s own technology. And then Bioinsec is proud to be strong durability and stability.
Over 100 hundreds of larger enterprises, academies and governments which have been
supplied with BKS-4‘00 have a reputation of it.
BKS-4‘00 is directly mounted CMOS camera on the main board which function doesn t
support in other company. It supports reduce the cost and gives high performance. And it can
be saved at captured user s image for access granted / failed and check image of visitor in
remote. In addition, it adds AC’” voice codec for high quality sound file and it can be possible
for downloading voice file (wav) to terminal and user can make their wanted language voice
file.
BKS-4‘00 is basically connected I/O Man which is supporting power supplied and easy
installation. It supports powerful solution through various I/O ports and it provide 12‘ x “4
size of LCD, 12 kinds of key, 5 kinds of function key for user friendly environment. When the
user try to access terminal, the access sensor is waking up, the light of LCD turns on, greeting
message is heard and web-camera is working at the point. Communication is TCP/IP basis. It is
possible to support RS-232/4‘5 Wiegand and dial up communication with optional board. And
you just can replace LAN Card with your wanted communication board.
The speed of CPU has updated from 200Mhz to 400Mhz. As a result, high speed processing
and recognition speed. We have made flash memory, LAN Card to be a module. If there is
some problem with those parts, user just replaces each part for recovery of terminal. In case of
standalone mode and disconnected situation, user can save recognition image through
inserting 1GByte Micro SD Memory Card ( T Flash ) in the terminal. These various factions will
help your high security system for access controller. And it can be widely used for enterprise,
lab, and academy etc.
www.bioinsec.com
-③-
Cadenacio device Manual
1-1 Product Specification
CPU
Memory
LCD
Sensor
32bit Micro processor,
400MHz
NAND Flash 12‘Mbyte, “4Mbyte RAM
1Gbyte Micro SD Memory Card (T Flash) Option
12“X“4 Graphic LCD
Optic, 500 DPI
Built-in 1.3Mpixel CMOS Camera
WebCam
Focal Length : 3.”mm
Iris : Fixed
Angle Of View : ’2˚(D)
Access Sensor
Size
Fingerprint data
size
Light is on: when a man approaches.
(H)1“0mm X (L)15“mm X (D)34mm
512 Byte
1:1 User : 10,000 Persons ( 1user with 1FP )
User
Registration
1:N User: 4,000 Persons (1user with 1FP)
RF Card : 100,000 Persons
Log data : 100,000 data
Image Saving : 1G SD Memory Card (Option)
Interface with Controller (I/O MAN)
IN/OUT port
Lock 2Port , Exit button, Fire Alarm, Door Sensor,
Lock Sensor, Output 2Port, Spare I/O 5Port
Communication
Language
/ Voice
Power
consumption
Options
www.bioinsec.com
TCP/IP on board, (RS-4‘5, RS-232, Wiegand optional card)
Korean/English/Italian etc.. (supporting multi language select)
User-configuration for making voice guide through Wav file
350mA
RF-Card, Key Phone, Sub-reader
-④-
Cadenacio device Manual
1-2 Product Feature

High-performance CPU use

It supports fast recognition to use 32 Bit 400 MHz ARM CPU.
Built-in mass storage memory
It basically built in 32Mbyte NAND flash memory.
There is socket which supports mounting Micro SD Memory Card for saving image. If
you mount 1G or 2G T-Memory Card, there isn t any problem for saving log and
image saving.

Mounting for various external RF reader
It is possible to mount EM, MIFARE, etc.
It can configure In/Out reader with other company s RF reader through 2 kinds of
Wiegand Input Port.



Web Camera Function
Saving image for access succeed / Fail image through built in camera in OnBoard
Remote control and visitor view by videophone ( Option )
Interlocking speed gate
It can be set for door open time by 1/10 sec unit.
It is possible to set door lock open time at least 0.5 sec unit to interlock speed gate.
Interlocking parking system
It supports for One terminal with 2 reader for IN/OUT.
I/O Man is design to control each relay for each reader for interlocking parking
system.

Access
sensor with greeting message
When someone try to access terminal within 1 M, the LCD turn the light on ,
working web-camera and listening greeting message due to access sensor.

Built in Key phone ( Option Board )
Connect PBX in the internal company. And call with external number with using BKS
4‘00 and external number through phone. It is possible to open door with pressing
password in the phone for customer to be able to come in.

AC97 voice file play
(playing wav file)
It supports high-quality sound and downloading voice file or sound source which is
made by user.

Supporting Multi language
Language is selectable through menu of terminal. Voice guide can be changed after
www.bioinsec.com
-8-
Cadenacio device Manual
recording.

Installation I/O Man for Control access door & Extension of I/O
I/O Man and BKS-4‘00 is communicated with encrypted data through exchanging
key for high security.
I/O Man can t communicate with new terminal without pressing set up button for
doing encrypted communication both of all.

It supports various I/O ports including fire alarm.
It supports 2 kinds of relay.
Reliance on using fingerprint
It solves the security problems which can be happed in case of using card system or
keypad system like as copied card, losing etc.

Reliable fingerprint algorithm
FAR and FRR is minimized by development of Bioinsec s own algorism.

Applying control for access door and management Time & Attendance

TCP/IP built in the terminal is able to manage many terminals.

Supporting Flexible function key for managing time & attendance
4 kinds of programmable function key and designated time & attendance code up
to ’ kinds are to be flexibly use for managing Time & Attendance. You can adopt
various functions with one terminal.

Management with low cost
Regarding ID card, it needs to be re-issue for new user and missing it and it needs
cost. But if you use fingerprint terminal, there doesn t need any extra additional fee.

EM or MIFARE card can be used for built in RF reader in terminal from each reader s
sort.

Standalone mode or Network connection
Bioinsec s fingerprint access controller system can be used for standalone or TCP/IP,
RS-232, RS-4‘5 and MODEM with server. And it is possible to make your own
program with using SDK supplied with product package. BKS-4‘00 have their own
RTC and management for log (Up to 10,000) and it can be used for time&
attendance without I/O Man (Lock controller)

User time zone setting and reporting
It is possible to download timezone, schedule from server to terminal by weekly or
monthly.

High-Speed user download

It takes just 10 seconds to download 10,000 users from server to terminal.
Automatically transmission log
When the terminal and server is connected, the log is automatically transmitted to
www.bioinsec.com
-9-
Cadenacio device Manual
server and then deleted in terminal.
2. The matters to be checked
2-1 Precaution / Emergency
- The matters that demands special attention for safety
Don t turn the power on when there is the impurity in plug.
Don t operate with wet hand nor let water inside the machine.
Don t install electro flow or a leak of electricity.
Don t install in place under direct sunlight, water, severe change of temperature and
explosiveness.
Please be careful to install or move the terminal by customer.
Don t install the terminal in damp or dusty place because it can be happened electronic short
and failure.
Set up terminal internal place. When you must terminal outside, please make supplement box to
protect terminal at out side environment.
Refer wiring installation manual for set up terminal.
Enroll master ID and his fingerprint after installation terminal.
Don t put the alcohol, benzene, water like as liquid and pin, needle like as metal in the
fingerprint optic sensor.
Be careful not to go into drink, water, drug like as those liquid in the terminal
Don t drop terminal and give strong shock.
Don t spray water on it to clean nor wipe it off with benzene, thinner or alcohol.
Don t carelessly break down or fix terminal.
※
If there are any accidents not to carefully use in the cautions, there is not
responsibility
www.bioinsec.com
- 10 -
Cadenacio device Manual


The matter should be done at first time
Change system password for your security.
Default setting password at manufacturing site : 1111
Power should be supplied after all cablings are completed.
When you can t verify fingerprint well
Try again, after removing some dirties and water on fingerprint
Please lightly place finger on the sensor.
Don t move fingerprint when the fingerprint is sensing.
In case of fingerprint hard to be processed
When device is in disorder without special problem, Just push Reset switch, then it s
back to setting status before latest trial.
You can call anytime to customer support center for your trouble.
www.bioinsec.com
- 11 -
Cadenacio device Manual
2-2 Terminal Configuration
LED
Green(Success) / Red(Fail)
Built-In web camera
Speaker
- Voice guidance
- Beep sound
LCD
Access
Input fingerprint
Sensor
RF Card reader part
Mic
- MIFARE (13.5“Mhz)
- EM (125Khz)
Call button
- HID Prox
Keypad
- Setting environment
- Input ID
- Input Password
www.bioinsec.com
- 12 -
Cadenacio device Manual
2-3 Icon Guidance
Network(TCP/IP) communication connected status with server
TCP/IP communication disconnected status with server
Serial communication connected status with server
Serial communication disconnected status with server
MODEM communication connected status
MODEM communication connected status with server
Try to connect MODEM connection
MODEM communication connected status with server
A mark for communication line between terminal and I/O Man
Locking status
Unlocking status
Forced lock status
Forced open status
Locking status by scheduled
www.bioinsec.com
- 13 -
Cadenacio device Manual
Unlocking status by scheduled
Lock down status
Lock open status
Attend (Sign for entering internal )
Leave (Sign for doing out outside)
Going out
Going In
Access
www.bioinsec.com
- 14 -
Cadenacio device Manual
2-4 Screen Information & Voice Guidance
File Name
Operation
Voice Guidance
100.wav
Access Granted
Succeed
101.wav
Access Failed
Sorry, Authentication failed
102.wav
There is not user registration information.
103.wav
Screen for entering user card
Please enter your card
104.wav
Screen for placing user fingerprint
Place your finger on the sensor.
105.wav
Screen for entering user’s PIN
Please enter your PIN code.
106.wav
Screen for contacting card or fingerprint
107.wav
Screen for entering user’s card or PIN
108.wav
Screen for user’s fingerprint and PIN
109.wav
Screen for entering card, fingerprint and PIN.
110.wav
Screen for retrying
Try it again.
111.wav
Screen for administration menu
Please enter your master
112.wav
Screen for registration user
Enrolled
113.wav
When user registration is failed
Registration failed
114.wav
When the date deletion is succeed.
Deleted
115.wav
Other operation sound effect
Updated it
120.wav
Success sound effect
Pee rick”
121.wav
Fail sound effect
“Pee beek”
122.wav
Sound effect for input card
“Peek”
123.wav
Sound effect for input fingerprint
“Ding dong”
124.wav
Button sound effect
“Peek”
125.wav
Alarm sound effect
“Siren”
126.wav
Greeting
“Thank you for visiting
Sorry you are not register please
confirm and re-try it
Please your enter your card or
fingerprint
Please enter your card or pin code
Please enter your fingerprint or pin
code
Please enter your card, fingerprint
or pin code
116.wav
※
It is possible to make sampling data of 24Khz when voice file is made by 16bit /
11Khz. After making wanted voice files and make same file name and download to
terminal.
www.bioinsec.com
- 15 -
Cadenacio device Manual
2-5 The Proper Method For Registration And Input Of
Fingerprint

The proper method of fingerprint input.

The proper method of fingerprint position.
www.bioinsec.com
- 1③ -
Cadenacio device Manual
3. Terminal Setting
3-1. Menu Setting
‘ Button Information to use terminal >
It is clear key for moving to the upper menu stage without saving and cancel.
It is arrow key which can manage curser scroll down or up.
It is enter key for confirming the selection mode and getting into the lower menu
stage and saved.
1) It is asterisk key in grouping mode to mark all figures in the other place of ID
number,
2) browse all user list for using wild card.
3) mark & delete check (√) and . When input IP address at network mode.
It is sharp key for deleting and like as back space key.
www.bioinsec.com
- 1④ -
Cadenacio device Manual

Master Login
Administration menu allows new user registration,
edition, deletion and system setup. Push 0” and
enter key button and input ‘1111’ as the initial set
value. And go to administration menu.
BKS480
Enter Password:
****
※
If you loose Admin’s password, turn
ON
BioInSec
Admin’s
passing switch in the terminal and go to change into
Admin’s mode. Then you can change your password.

Selecting Menu
First time, when entering into menu, there are 3 kinds
Administration
of menu in the LCD. But, it is possible to see one more
menu
with managing arrow key for 3 times. It is
possible to control menu by arrow key. After selection
menu and press ‘enter key’, there are sub menus. It is
1. User
2. Service
3. Door Setup
possible to select each menu by ‘enter key’.

Check Box
When there is menu for selecting multi items and
control up & down side with using arrow button. For
selecting and cancel of item, please use * key . Once
pressing of * button , it is selected. Twice pressing of *
key , it is canceled. Selected item is checked like as V .
After selecting item, if you press enter key , it goes
ID : 1234
1. FP
2. Card
3. PIN
higher menu. If user presses clear key , the setting
value isn t saved at this time.
www.bioinsec.com
- 18 -
Cadenacio device Manual

List Box
There is list box in the user registration menu for the
user registration. With using arrow button , go to
ID : 1234
menu of 3 FP1 and press enter key . It takes 3 times to
enroll fingerprint and LCD screen will be shown success
message. And Asterisk ( * ) appears in the right of
menu by saving like as right side image. If you want to
1. Save & Exit
2. Access Mode
3. FP1
improve the authentication rate or register another fing
er for convenience, push 2.FP2 and keep the same process as 1.FP registration. Card
is same as that method.

Wild Card
If user wants each user’s information by one by one,
User delete
just input each ID for deleting user information.
But user wants to delete all user, press ‘*’ button and
‘enter key‘. As like above wise, all user information are
Enter user ID:
deleted.

Scroll Button
For managing menu with scroll button, it needs to be
Button Volume
used by ‘arrow button’, The digits is going up, and down
with using Scroll button.
www.bioinsec.com
31
- 19 -
Cadenacio device Manual
3-2. The Organization Of Menu
FP
Card
Save & Exit
Access Mode
New User
1 User
Edit User
FP1
FP2
Delete
PIN
Card+FP
Card+PIN
Card+FP+PIN
Card
PIN
Security Level
Terminal Set
Very Low
Low
Normal
High
Very High
www.bioinsec.com
- 20 -
Cadenacio device Manual
Very Low
Low
Normal
Security Level
2 Service
High
Up/Down Key
Very High
No-F1-…-F4
Free Scan
F1-…-F4-No
Key
Time & Attend
Display
Event
Items
Disable
Text
Icon
Timer
Delete
Output
Mask Event
Network
2③ Wiegand
34 Wiegand
Lock Event
Access
Other Event
www.bioinsec.com
- 21 -
Cadenacio device Manual
Authorize
Grant Active
Auth. Mode
1-Door
1-Door ( In/Out)
Door
Configuration
2-Door
Card Reader
FP Reader
Unreg. Alarm
Reader(In)
Door
Expired Alarm
Deny All
Card Grant All
Local
Wiegand1
Wiegand2
Reader(Out
Pulse Time
Input/Output
Time Delay
Alarm
Door Contact
RequestToExi
Disable
Input1
Input2
Relay2
OpenTooLongTime
OpenTooLong
Enable
ForcedOpen
Output
High Time
Low Time
www.bioinsec.com
- 22 -
Cadenacio device Manual
Very Low
Administrator
Terminal ID
Admin PIN
Low
Admin FP
Normal
Exposure
Very
Reader
4 System
High
Set Date
Date & Time
Set Time
Monitor
User Volume
Admin
Sound
Camera
BackLight Time
LCD Contrast
LCD Brightness
Button
Run/Stop Mode
Automatic
Door Phone
Operation Mode
Volume
Open Number
Speed Dial No
Tone
Manual
Disable
Inter Phone
Standard
Speed Dial
Single Number
Silence Time
Tone Check
Ringback
Busy
Fast Busy
www.bioinsec.com
- 23 -
Cadenacio device Manual
MAC Address
Network Mode
Dynamic Address
5 Network
Local IP Address
Subnet Mask
Gateway
English
③ Language
Italian
Korean
Server Host
Server Port
www.bioinsec.com
- 24 -
Cadenacio device Manual
3-3. Detail Menu Explanation
www.bioinsec.com
- 25 -
Cadenacio device Manual
1. User
This menu is for user resistor, edit, delete and access method.

New User
[Input User ID] is for registration user ID.
If there is already registered user ID, there is message like as [Overlapped ID].
When new user is created, there are items of menu.
① Save & Exit
This menu is for saving user information. If user doesn t select this menu, the
user information is canceled. After finishing date, message of [data is saved] is
shown.
② Access Mode
This menu is for setting of user access method.
1 : FP
2 : Card
3 : PIN
4 : Card+FP
5 : Card+PIN
“ : Card+FP+PIN
It is possible to select multi selection. From 1 and 3, user can get access granted
with just 1 method. From 4 to “, it needs to get access granted by its turn of
combination.
③ FP1
User can save user s 1st kind of fingerprint. The sensor read fingerprint for 3
times.
④ FP2
User can save his/her 2nd
kind of fingerprint. If you want to improve the
authentification rate, you can re-enroll same fingerprint in FP2. The sensor read
fingerprint for 3 times.
⑤ Card
Users can register his/her card in the terminal. Contract card to RF module
under the fingerprint sensor and you can hear
Bee sound and contact again
for final registration of card.
⑥ PIN
www.bioinsec.com
- 2③ -
Cadenacio device Manual
Users can register his/her PIN code in the terminal.
User should enter PIN code from 4 and ‘ digits for twice. When 1st PIN code
needs to be same as last thing, the PIN code is saved. If the date is not same,
user can see message like as [ Incorrect ! ]. When user sees this message, please
input PIN code again.
⑦ Security Level
User can set the security level by personal.
1 : Terminal Set ( Its level is up to terminal s setting )
2 : Very Low
3 : Low
4 : Normal
5 : High
“ : Very high

Edit User
After pressing user ID which needs to be edited, user can see same sub menu like as
new user registration. Select item which will be revised and input new data. If you want
to change authentication method on target ID, scroll down to the target ID by arrow
button and touch enter key and it is ready to change. If you keep push * button for
seconds on edit user, it shows all ID list in BKS-4‘00.

Delete User
For checking user ID to be deleted, please message appears at [1:Yes 2:No]. If you select
[1:Yes], the user ID is deleted. If you select [2:No], the deleted is canceled.
Delete user is finished. Voice message announces as [ Deleted ]. If you want to delete all
user data, press * button and enter key . It will be shown to select [1:Yes 2:No] as user
deletion. After finishing deleting user, Voice message announces as [ Deleted ]
2. Service
www.bioinsec.com
- 2④ -
Cadenacio device Manual
This menu is for management of function of BKS-4‘00

Security Level
This sets the security level of terminal
If user sets security level as [terminal setting], his/her security level effects on
below
setting.
1 : Very low
2 : Low
3 : Normal
4 : High
5 : Very high
There are 5 level of setting security level for fingerprint identification.
If the security level is higher, it has possibility of high FAR (fail accept rate) but has
possibility of low FRR (false reject rate).
If the security level is lower, there is possibility to be high of FAR (false accept rate).

Free Scan

Time & Attend
① Key
For being shown Time & Attendance function on LCD window. It s set the
function key between arrow key and side key.
1 : Arrow Key
2 : No-F1-…-F4
3 : F1-…-F4-No
② Display
T&A status is shown at LCD.
1 : Disable ( When you don t want to use T&A function, just check )
2 : Text
( Display message as IN, OUT, ABSENCE, etc )
3 : Icon
( Display icon as same step as text )
③ Items
1 : Enable ( Select each item for enable or not )
2 : Text
( Select text for each function key )
3 : Icon
( Select icon for each function key )
④ Timer
⑤ The timer is for setting time on LCD. ( 0=always, 1~255 sec )

Event
BKS-4‘00 store many event log records included the lock event ( door open/close ),
www.bioinsec.com
- 28 -
Cadenacio device Manual
Access Event and Other Event. If you don t want to store Lock Event data, disable it.
When BKS-4‘00 use for standalone mode and no need the Log record, sometimes push
Delete Event stored Event or disables all Events. It helps the fast operation speed to
prevent from full memory data.
① Delete Event
Delete event to be set
② Output Type
This is for selecting data output type.
1 : Network
( Log is transmitted to connected server )
2 : 2“ Wiegand
( Log is transmitted to ACU )
3 : 34 Wiegand
( Log is transmitted to ACU )
③ Mask Event
If you don t want to store the events for each menu, please click it in the check
box.
1 : Lock Event ( If its menu is enable, lock event doesn t transmit to server )
2 : Access Event ( If its menu is enable, access event doesn t transmit to server )
3 : Other Event ( If its menu is enable, other event doesn t transmit to server. )
www.bioinsec.com
- 29 -
Cadenacio device Manual
3. Door Setup

Configuration
① 1-Door
② 1-Door (In/Out)
③ 2-Door

Door
① Reader(In)
1 : Auth. Mode
- Authorize
- Grant Active
- Deny All
- Card Grant All
2 : Card Reader
- Local
- Wiegand1
- Wiegand2
3 : FP Reader
4 : Unreg. Alarm
5 : Expired Alarm
② Pulse Time
③ Input/Output
1 : Door Contact
- Disable
- Input1
- Input2
2 : RequestToExit
3 : Relay2
④ Time Delay
⑤ Alarm
1 : OpenTooLongTime
2 : OpenTooLong
- Enable
- Output
- High Time
- Low Time
3 : ForcedOpen
www.bioinsec.com
- 30 -
Cadenacio device Manual
4. System
It is a manual for changing terminal system setting.

Administrator
① Admin PIN ( Password )
It needs to change admin password to log in terminal from 4 and ‘ digits. Its
default admin password is 1111. And it needs to change Admin password for
security. If user set new admin password, it needs to input same password for
twice to check its password. If the data is incorrect, it is shown a message like
[incorrect data!]. And you need to try it again.
② Admin FP ( Fingerprint )
It is possible to log in terminal by registered administrator s fingerprint which is
possible to enroll and revise. At default setting, it doesn t have any fingerprint as
an admin fingerprint. If user wants to log in terminal by admin fingerprint, it is
possible to use that function. It takes 3 times scanning time for making accurate
fingerprint template data.

Terminal ID
Whenever you use many terminals, it is possible to designate ID for identifying each
terminal. ( 1~’’’ )

Reader
① Exposure
It can control the sensor exposure time to get more high quality image.
If fingerprint is dry, it would be better to set high level. If the fingerprint is wet,
sensor s exposure is set to low. User check fingerprint status, it will be helpful to
be high verification rate. You can check the fingerprint image from BioManager as well. First, check the image remained on terminal and you select the
most clear image level.
1 : Very Low
2 : Low
3 : Normal
4 : High
5 : Very High

Date & Time
① Set Date
www.bioinsec.com
- 31 -
Cadenacio device Manual
This is the menu used to set the date.
(YY/MM/DD – Year/Month/Date)
Once, the date is fixed, the date keeps going if the power isn t supplied.
It is possible to set the date at program.
② Set Time
This is the menu used to set the date and time (HH:MM:SS).
Once, the time is fixed, the date keeps going if the power isn t supplied.
It is possible to set the date at program.

Monitor
① BackLight Time
This is the menu to choose the time for LDC back light. (0=always / 1 ~ 255 sec)
When the digit is set to 0 , it means the light is on all the time.
After setting this time, there isn t any additional input, the back light turn the
light off.
② LCD Contrast
This can adjust darkness. (from 0 to “3). The setting value is higher, the screen is
darker
③ LCD Brightness
This can adjust brightness of LCD screen from 0 to ”. The setting value is higher,
the screen is brighter. The selected grade is higher; the brightness of screen is
brighter.

Sound
① User Volume
② Admin Volume
③ Button Volume
This is the menu to adjust the sound volume when users press button from 0 to
31.

Camera
Select active mode of camera which is built in.
①
Run / Stop Mode
1 : Automatic
- This is to be connected with LCD s backlight and when user accesses, camera
is working. Once LCD s backlight is off then, camera is stopped.
2 : Manual
- If you make camera working always, you need to change into manual mode.
Manual mode is different from Auto mode, so Manual mode can be stopped
or after electricity is blowing out and then it keeps working always. ( Caution :
www.bioinsec.com
- 32 -
Cadenacio device Manual
At manual mode, user should work at Manual mode serve menu.)

Door Phone
It is possible to connect with internal exchange phone
and it is possible to make a
phone with Internal conversation.
Key-phone module should be built in the terminal for working.
① Operation Mode
1 : Disable
2 : Inter Phone
3 : Standard
- This is general internal phone mode so if call button is pressed after that
calling sound is being heard. If visitor pressed internal phone number,
receiver phone is being dialed by using terminal Keypad. If receiver gets the
phone call, then it is able to have a conversation.
4 : Speed Dial
- This is short number mode, press
Call button
and press stored short
number then it is possible to have a conversation.
5 : Single Number
- This is Single Number Mode, press
Call Button
and connect exchange
person ( Connecting number is Speed dial number is 0 )
② Volume
It is possible to change volume for User, Admin etc.
③ Open Number
During phone call, by using dial button, you can set password number for
opening door
④ Speed Dial No
At operation mode, if user use speed dial number mode, it is to enroll for being
applied to speed dial no.
⑤ Tone
There is no standard of tone so different kind of sounds come out per exchange
phone. In this case, if basic setting is not matched with sound, you can set
regarding serve sound.
( On /Off time setting is available from 1~’0  0.1sec at distance )
1 : Ringback
2 : Busy
3 : Fast Busy
⑥ Silence Time
www.bioinsec.com
- 33 -
Cadenacio device Manual
Without sound conversation, when key phone is turned on, as waiting time, after
this time, automatically, please hang up the phone.(0~255) 0=always
⑦ Tone Check
5. Network
This menu is with network setting for managing terminal. There are 3 kinds of network
setting type.
※ Menu for TCP/IP Mode
① MAC Address
It is for checking MAC address of terminal.
② Network Mode
This menu is for using TCP/IP [ LAN ] as communication mode.
1 : Serial
2 : Dial-up
3 : TCP/IP
③ Terminal IP ( Local IP )
It is for setting terminal s IP mask of terminal.
Its IP is for terminal and needs to do ping to communicate with server.
[.] is managed by * button.
④ Subnet Mask
It is for setting subnet mask of terminal.
Regarding gateway, you can check it network environment of server. It absolutely
needs to be same as server.
[.] is managed by * button
⑤ Gateway
It is for setting gateway of terminal.
Regarding gateway, you can check it network environment of server. It absolutely
needs to be same as server.
[.] is managed by * button
⑥ Server IP
It is for server IP which is for managing terminal. Regarding server IP, you can
check it network environment of server.
[.] is managed by * button.
⑦ Server Port
It is for server port of managing terminal. (1~“553“)
Default value is ‘00‘
www.bioinsec.com
- 34 -
Cadenacio device Manual
※
Menu for Serial Mode and Dial Up Mode
① MAC Address
This mode is for checking MAC address of terminal.
② Network Mode
This mode is for setting the network of terminal.
③ Serial Speed
This mode is for setting the serial speed of terminal.
1 : ’“00
2 : 1’200
3 : 3‘400
4 : 5”“00
5 : 115200
6. Language
It is to choose language for LCD Screen.
① English
② Italian
③ Korean
www.bioinsec.com
- 35 -

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Extract, Print high-res
Author                          : MYHOME
Create Date                     : 2010:04:07 11:10:39+09:00
Modify Date                     : 2010:04:08 19:26:48+09:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2010:04:08 19:26:48+09:00
Producer                        : Acrobat Distiller 9.3.0 (Windows)
Format                          : application/pdf
Title                           : Microsoft Word - Cadenacio Device Manual[ENG6.0].docx
Creator                         : MYHOME
Document ID                     : uuid:0814edfd-f9f2-42b4-8108-e8bb30f11a1b
Instance ID                     : uuid:d45b5e98-b33f-4dc9-8211-bd3afea49c48
Page Count                      : 35
EXIF Metadata provided by EXIF.tools