Bissell 1672 User Manual DEEP CLEANER Manuals And Guides L0905224
BISSELL Power Steamer Manual L0905224 BISSELL Power Steamer Owner's Manual, BISSELL Power Steamer installation guides
User Manual: Bissell 1672 1672 BISSELL BISSELL DEEP CLEANER - Manuals and Guides View the owners manual for your BISSELL BISSELL DEEP CLEANER #1672. Home:Vacuums & Floor Care Parts:Bissell Parts:Bissell BISSELL DEEP CLEANER Manual
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
1672 SERIES 3 4 5=6 6-11 12 13 14 15 16 We're glad you purchaseda BISSELLBig Green®multi-purposedeep cleaner.Everythingwe know aboutfloor care went intothe design and constructionof this complete,high-tech homecleaningsystem. YourBig Greenis well made,and we back it with a limited two-year warranty.We alsostand behind it with a knowledgeable,dedicated ConsumerServicesdepartment,so, shouldyou ever havea problem,you'll receivefast, considerateassistance. My great-grandfatherinventedthe floor sweeperin 1876. Today,BISSELLis a globalleaderin the design,manufacture,and serviceof high quality homecareoroductslike your Big Green. Thanksagain,from all of us at BISSELL Mark J. Bissell Presidentand Chief ExecutiveOfficer 0 Groundin_Pin 0 Large Vacuum Flex Hose Clips_ Grip/Trigger Vacuum Flex Hose WandSolutionTube ,p Power Unit Motor Filter Measuring Cup Ball Cage D Tank Unit Tank SiphonTube i Floor Nozzle 0 This User'sGuidehas been designedto help you get the most satisfactionfrom your BBSELLBig Green.You'll find assembly and operatinginstructions,safety precautionsand pre-cleaningtips, as well as maintenanceand troubleshooting instructions.Pleaseread this Guidethoroughly beforeassembling your Big Greencleaner. Payparticularattention to the productdiagram, assembly instructions,and part names.Locateand organEeall pars beforeassembly.Familiarizeyourself with the parts and where they fit. Followingthis User'sGuidewill greatly enhanceyour ability to get the most performancefrom your BBSELLBig Greenfor many years. Casters. Locate4 casters nside plasticpackagingin collectiontank.Turntank unit upsidedown insertfour castersand push untilthey snao ntoplace. Bail, Placeball on raisedarea of recoverytank bottom. Ball NOTE:Ball may havean unusualcolor due to recycled high density polyethylene(NBPE)used in its manufacture. Bail Cage. Positionball cageoverbali and presscage firmlyonto raisedarea. TankUnit Motor Filter. Locatemotorfilter and insert it into cavity on the undersideof the top powerunit Tank Unit. Flipcarrying handledownoverfilling cavity on tank unit. To_ Power Unit Motor_ Filter TopPower Unit, Placetop powerunit on tank unit. Twist top power unit until it drops into place on tank unit. Flip up carrying handleto lock units. Aluminum Wands. Fit bottomwand sectionintotop aluminumwand section.Latch out,on clODS throughhole to lock sectionstogether. NOTE:Wands are identical and interchangeable. Buttons must be on upper end of wands for properassembly. Aluminumwands fit together snugly. FloorNozzle. Fit floor nozzleoverbottomwandand lock with latch button. Grip/TriggerUnit. Fit grip/triggerun_ mo _ouwand lock with latch button. 0 WandSolution Tube. Connectwand SOlUtton tube to spraytip on floor nozzleano to cao valveon grip/triggerunit _ Wand Solution Tube Vacuum Flex Hose mall Wand Clips.Securetuoe [o wano wt_ntwo small Hose with Threaded Connecl %S wandclips. Vacuum Flex Hose. Connectvacuumflex hoseto grip/triggerunitand lock with latch buttons.Insertvacuum flex hoseinto inleton top powerunit and lock _ place. I__-- Hosewith ThreadedConnectors.Attach hosewith threadedconnectorsto threadedoutleton grip/[rigger unit. Fingertighten only.Presshoseinto moldedslot unoergrip/trigger unit.Attachotne[ end to threaded outlet on powerunit. Fingertighten only. Grip/Trigger ICap "¢_ Vacuum Flex HoseClips. Holdvacuumflex noseano ! hosewith threadedconnectorstogether.Snapthree largevacuumflex hoseclips in placeat three clip bands on flex hose. Tank Siphon Tube. Pull up tank siphontube nex[ _o filling cavityon tank unit. insert firmly intoopeningon powerunit. Make sure the power and tank units are properly aligned and locked with the carrying handle before pulling up siphon tube assembly and inserting it into power unit, Assemblyis now complete. Seeindividualsectionsfor properusageof all accessories __Bare Floor Attachment For Dry Vacuuming Dusting Brush /_y Floor Nozzle Dry Filter Bag_ Small Vacuum Nozzle CreviceAttachment 0 Vacuumcarpet (seepage 10, HOWTO DRYVACUUM,. Decidewhereto begin and ena your.o_).Cleanin 3' X 4' sections,startingin areasfarthest from exit. Plan to leavea pathopen to emptyCOlleCtion tank ana replenishfilling cavity. Carpetingwill dry in two to four nours,aependingon carpetstyleand air circulation_ room.A floor fan speedsdrying. Planactivitiesto givecarpett_meto dry. Replacefurnitureon damocaroetingby placingwaxea paper underlegs untilfloor driescompletely. Checkmanufacturer'stag beforecleaning "W" or "WS" on the tag meansyou can useyour Big Green.If tag is codedwith an "S" (with diagonalstrike-through),or says "DryCleanOnly,"do not proceed. If manufacturer'stag is missingor not coded,checkwith your furnituredealer. If possible,check upholsterystuffing.Coloredstuffing may bleedthroughfabric whenwet. The Big Greenis not recommenaeafor c_eaning woodfloors. UseonlyBissell®FloorCarecleaningsolutionon no-wax floors.Neveruse Bissell®Carlet Cleaneror other carpet cleanerson barefloors. Sweepbeforestarting. Removeold wax beforecleaning. Leavean exit path. Allow at least1/2 hourdryingt_me. @ Measuring Removedryfilter bagfrom bal cage. up O emoveconcentratemeasunngcup from filling cavityon Remove Measuring Cup From Filling Cavity sideof tank unit. Pourtwo gallonsof hot tap water (temoera_ure sllould not exceed120° F/48° C)into filling cavity un_ttlevel reachesbottomof three verticallinesin tank unit. Shakebottle of BISSELLCarpetCare.Fillmeasuringlid to fill line (10 ounces).Emptymeasuringlid into filling cavity and replacemeasuringlid. Plug powercord into approvedgroundedoutlet. Pre-treathighlysoiledareas:Presson pump/spray b switch,hold floor nozzle4"- 6" abovesoiledcarpet,and pull trigger to spraycleaningsolution. Wait 5-I0 minutes.Scrubtoughstainswith floor nozzle P brush. Turnon pump/sprayand vacuum/suctionswt_cnes.Place i floor nozzledirec:tlyon carpetat arm's length.Pul trigger to spray cleaningsolutionwhile pulling wand_owarayou. Repeat,keepingfloor nozzlefirmlyagainstcarpet I surface,Continueuntil no moredirt can be removed. Do not overwet. O eleasespraytrigger.Vacuumarea until no more cleaningsolution can be removed. Continueto cleanentirecaroet,working _ 3' x z[,sections. O 0 f the macn_neosessuction,slops sprayingand/or motor noiserises in pitch,emptythe tank [seeWHENYOU'RE DONE.page 9]. Failureto emptytank will damageunit. ane cnecKcleaningsolu[_on ever runmmediately pumpdry. If floor nozzles_oossprayingrevel. turn N off Dumb Vacuum/suction switch Turnoff pump/sprayand vacuum/suctionsw_cnes. Unplugfrom outlet. Removetank siphontube,flip aowncarryinghandlearia lift top powerunitfrom tank un_. Carrytank unitto a toilet or sink _oempty.With carrying handlein one hand,placeother nano'_ grippingslot underfilling cavity on tank unit. Lift and Dour_Oempty. Make sureball and ball cageare firmly sea_eoon raisedarea.Replacepowerun_ and _OCK in placewith carry handle. See PUTTING ITAWAYon page12. Disconnectwandsolutiontubeand aluminumwands from grip/trigger unit. MoistenO-ringat baseof cap valvewith soapywater. Align smallarea cleaningnozzlewith cap valveand vacuumtube on grip/trigger unit. Presslatch button on vacuum_uDeand slide smallarea cleaningnozzleon until latch button locksin place. Checkmanufacturer'stag and/ortestfabric in an inconspicuousplace. Turnon vacuum/suctionand pump/spraysw_cnes. Depresstrigger and pull small area cleaningnozzle towardyou. Releasetriggerand repeataction _Oex_rac_ excessmoisture. Vacuum/suction switch Repeatuntil area is clean. SeeWHENYOU'REDONE,aboveand PUTTING ITAWAY. page 12. 0 Attachbarefloor attacnmem_obottomof floor nozzle with rubberand brushstrips facingout. Align front edges and snaptogether. Fill measuringlid twice with BissellFloorCareand empty intofilling cavity. Nozzle Vacuul Jsuction switch Pourtwo gallonsof hottap water into filling cavity. ) Waterlevelshouldreachthe bottomof threevertical lines in tank unit. __are _ Pump/spray Turnvacuum/suctionand pump/sprayswitcheson. Depresstriggerand pull floor nozzletowardyou. Releasetriggerand repeatactionto extractexcessmoisture. Disconnectbarefloor attachment.Turnoff maclline,hold I floor nozzleawayfrom you, pushbare floortool off with thumbs. SeeWHENYOU'REDONE,page 9 and PUTTING IT AWAY, page 12. Makesure tank unit is dry beforeproceeding. Checkmotor filter.Cleanif necessary. Pull dry filter bag overball cage,ca[changedgeof bag overlip at bottomof cage. Placebail on raisedarea a[ bottomof tank _n_t Positionbal cage overball ano oressfirmlyon[o raisedarea. Remove_wosmall aluminumwanocl os ano floor nozzle from wano. @ _!i_,_._ur Floor Attachment Attachone of four dry vacuuminotools. O Inserttank sipllontube in tank unit. Turnon vacuum/suctionswitch.Vacuumas usual. _ Emptycollectiontank wllen it is half full. SeePUTTING ITAWAY,page12 Vacuum/suction switch h O Removedry filter bagfrom ball cage. Placeballon raisedareaon bottomof tank unit. Positionball cageover ball and pressfirmly onto raisedarea. Inserttank sipl_ontube in tank unit. Attacl_barefloor tool to floor nozzle. Vacuum/suction switch Turnon vacuum/suctionswitch.Donot turn on pump/sprayswitch or pumpdamagemay occur. _J PlaceBig Greenin a dry areaof the floor. Vacuumas usual. If the machinelosessuctionand!or motor no_serises _ 9_cn.empty the tank [seeWHENYOU'REDONE].Failure_oemp_/_anKw_ damageunit. SeeWHENYOU'REDONE,page9 ana PUTTING IT AWAY.page 2. ® Rinsefilling cavity witn aean wa_er.Leaveabout1/2 gallonof cleanwater in filling caw_y. Holdfloor nozzleoverbucketor sink. O urn on pump/sprayswitch,pull trigger for 30 seconos, and emptypowerunit. Emptyfilling cavityof excesswater. Drainsolutionhoses. Emptyand rinsecollectiontank. R nseand dry collectiontank.ball cage.ball.wanos and tools. Removetank siphontube from openingon powerunit. O emovefilter from end of tank siphontube, cleanfilter under runningwater,then replacefilter in end of tank siphontube. Replacetank siphontube m openingin powerunit. Werecommendthat youair dry beforeclosingunit for storage. Removemeter filter from top power Jn_ano nnse with water.Squeezeto removewater,then air dry before reinstalling.Cleanafter eachvacuuming. Removedry filter bag from Dal cage. Shake_oremove surfacedirt. Rinsebag oy hand _ warm water.Air dry beforereinstalling. @ [ter Weak or no suction/ motorsuddenlyruns louder/ motor runs hot. PossibleCauses Remedies O Vacuumis notoperating O Checkelectricalplug Vacuum/switchon? CallBISSELLConsumerServices(seepage15) O Collectiontank unit is full O Air leak O Emptycollectiontank O Dirtyfilter(s) O SeePUTTING ITAWAY, After DryVacuuming, Steps1-2 (seepage 12) O Powerunitimproperlyattached O Repositiontop powerunit on tank unit Carryinghandlein placeto lock tank unit and top powerunit? O Kink/blockagein hoses/tubes O Straightenhoses/tubes Checkaluminumwands/vacuumflex hose/solutionhoseand tubefor obstructions O Checkall vacuumconnections Secureall latch buttons Reducedsprayor no spray/ Leakingconnections. PossibleCauses Remedies O Tanksiphontubefilter clogged O Fillingcavity empty Q See PUTTING ITAWAYSteps9-11 (seepage12) O Refillfilling cavity O Spraytip clogged O See PUFFING ITAWAYStep8 (seepage12) O Tanksiphontube/Solutionhose/ Wandsolutiontube kinked/disconnected O Tightenlooseconnections Relaxkinksin solutiontubes/hoses O Pumpis not operating O Checkelectricalplug Pump/sprayswitch on? CallBISSELLConsumerServices( seepage15) O Connectionsnottight O Fingertightenall connections (do not usepliersor othertools) A WARNING: To reduce the risk of fire, electric shock or injury unplug from outlet beforeservicing. ® item Part No. PartName 1 210-4706 Vacuumflex hose 2 555-9129 3 555-9013 Largevacuumflex hoseclips (3t Hosewith threadedconnectors 4 216-4181 Grip/triggerunit 5 210-1188 6 010-9156 Dustingbrush Creviceattachment 7 010-6055 Smallvacuumnozzle 8 213-9152 Drainclean-out attachment 9 10 203-1659 555-9008 Capvalveassembl_ Wandsolution tube 11 12 555-6502 215-9151 Smallwand clips (2) Smallnozzle 13 555-9044 Aluminum wands (2. interchangeable) 14 15 603-2920 017-3533 Top powerunit Motor filter 16 213-3537 Filter bag 17 213-1526 Ball cage 18 19 213-3004 213-0329 Measuringcup Ball 20 215-9075 Tankunit (includesfilling cavity,collectiontank. and handle 21 214-1523 Wallstorage rack with screws (optionalon /optionalon some models 22 23 555-9011 555-9036 Tanksiphontube Tanksiphontube filter 24 210-2283 Caster(individual/ 25 210-4740 Dry floor nozzle 26 27 215-6150 555-9005 Spraytip Floornozzle 28 555-9003 Floornozzlebrush 29 213-0471 Barefloor attachment 2 5 8 13 21 @ 22 23 0 Forinformationaboutrepairsor replacementparts,or questionsaboutyour warranty,call: BISSELLConsumerServices 1-800-237-7691 Monday- Friday 8 a.m.- 10 p.m ET Saturday 9 a.m.- 8 p m ET Or write: BISSELLHomecare,Inc. PO Box3606 GrandRapids, MI 49501 ATTN: ConsumerServices Orvisitthe BISSELLwebsite - www.bissell.com Wllen contactingBISSELL,havemodelnumberof unit available. Pleaserecordyour ModelNumber: PleaserecordyourPurchaseDate: NOTE:Please keepyour original sales receipt, it is your warranty. Youmay purchasereplacementpartsfrom your retailer,byusingthe order form in this User'sGuide,bycallingBISSELLConsumerServicesor by visitingour website.Tolocatea retailernearyou, or to placean orderusing Visa,MasterCard,Discoveror AmericanExpress.call BISSELLConsumer Services 1-800-237-7691 Monday- Friday 8 a.m. 10 p.m. ET Saturday 9 a.m.- 8 p.m. ET Or visit our Website - www.bissell.com @ This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. If you need additional instruction regarding this warranty or have questions regarding what it may cover,please contact BISSELLConsumer Services by E-mail, telephone or regular mail as described below. Limited Two Year Warranty Subject to the *EXCEPTIONS AND EXCLUSIONSidentified below, upon receipt of the product BISSELLHomecare, Inc. will repair or replace (with new or remanufactured components or products), at BISSELL'soption, free of charge from the date of purchase by the original purchaser,for two years any defective or malfunctioning part. See information below on "If your BISSELLproduct should require service". This warrantyappliesto productusedfor personal,and not commercialor rentalservice.This warran_ doesnotapplyto fans or routinemaintenancecomponentssuch as filters,belts,or brushes.Damageor malfunctioncausedby negligence,abuse,neglect,unauthorizedrepair,or anyother usenot in accordancewith the User'sGuideis notcovered. If your BISSELLproduct should require service: Call BISSELLConsumer Servicesat the number below or visit the BISSELLwebsite v_t_v,bisseli.com to locate a BISSELLAuthorized Service Center in your area. If there are no authorized BISSELLService Centers in vour area, select the "CustomerService" tab, and follow the instructions for contacting us via email. A BISSELLRepresentative will issue you a Return Authorization Number and a pre-paid mailing label to return the unit to BISSELLfor warranty repair. The machine should be _eturnedwith a photocopy of your proof of purchase. (Your dated sales receipt isyour proof of date of purchase in the event of a warranty claim do not send original.) If you need information about repa=rsor replacement parts, or if you have questions about your warranty, select the "Customer Service" tab on our website and follow the instructions for contacting us by e-mail. Or call: BISSELL Consumer Services 1-800-237-7691 Monday - Friday 8 a.m.- 9 p.m. EST Saturday 9 a.m.- 5 p.m..EST Or write: BISSELL HOMECARE,INC. PO Box 3606 Grand Rapids M149501 ATTN:Consumer Services 31SSELL HOMECARE. INC.IS _]OTLABE FORNCIDENTAL ORCONSEQUENTIAL DAMAGES OFANYNATURE ASSOCIATED WITHTHEUSEOFTHISPRODUCT. BISSELUS LIABILITY WILLNOTEXCEED THEPURCHASE PRICEOFTHEPRODUCT. Somestates do not allOW above ilmltatlorl the exc JSlOn or ilrnltatlon or exclusion may not aDDIV Io of lcldenta or consequentialdamages,so the OL *EXCEPTIONS ANDEXCLUSIONS FROMTHETERM_OFTHELIMITEDWARRANTY THISWARRANTYSEXCLUSIVE AND N LIEUOFANY DTHER WARRANTIES EITHERORAL ORWRITTEN. ANY MPLIEDWARRANTIES WHICHMAYARISEB OPERATION OF LAW, NCLUDING THE MPLIEDWARRANTIES OF MERCHANTABILITY ANDFITNESS FORA DARTCULARPURPOSE ARELIMITEDTOTHETWOYEARDURATION FROMTHEDATEOF PURCHASE A,< DESCRIBED ABOVE Some sta_esdo no_allow _nl_a_lons or now long an repliedwarrant_ as_s,sothe above limitation _na no_aDDIV _0 /ou, @2003 BISSELLHomecare,Inc GrandRapids,Michigan All rightsreserved,Printedin USA PartNumber010-5859 Rev7/03 Visit our websiteat: www,bissell,com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 16 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Sun May 31 04:14:17 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools