Blue Tower Communications EM915V1 EM TransPondIT Meter Interface Unit User Manual EM915 manual

Blue Tower Communications Ltd EM TransPondIT Meter Interface Unit EM915 manual

Manual

Download: Blue Tower Communications EM915V1 EM TransPondIT Meter Interface Unit User Manual EM915 manual
Mirror Download [FCC.gov]Blue Tower Communications EM915V1 EM TransPondIT Meter Interface Unit User Manual EM915 manual
Document ID276359
Application IDiocU0Pi3s5Xxkx9fIn0D4A==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize21.16kB (264514 bits)
Date Submitted2002-10-11 00:00:00
Date Available2002-10-11 00:00:00
Creation Date2002-10-10 09:17:51
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2002-10-10 09:17:51
Document TitleMicrosoft Word - EM915 manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: RSeay

Part No. 950005501 IP 0A
Company Confidential
EM 915 V1.0
Manual
Prepared by:
Approved by:
JSteenson .............................
............................................……….
Signature
Date
..............................................
............................................……….
Signature
Date
This is an unpublished work the copyright in which vests in Advanced Technology RAMAR Ltd. All rights reserved.
The information contained herein is the property of Advanced Technology RAMAR Ltd. and is supplied without liability for
errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 1 of 20
Company Confidential
Part No. xxxxxxxx XX xx
Document Title
DOCUMENT HISTORY
Rev
CR-N No
Action
Originator
Date
Part No.
Doc Type
REFERENCED DOCUMENTS
Document Title
Advanced Technology RAMAR Ltd
7 Enterprise Way
Aviation Park
Christchurch
Dorset
England
BH23 6HB
Tel:
Fax:
+44 (0)1202 592000
+44 (0)1202 592001
E-mail: info@atr-group.com
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 2 of 20
Company Confidential
Part No. xxxxxxxx XX xx
Document Title
GLOSSARY
AMR
Automatic Meter Reading
BOM
Bill of Materials
EIRP
Effective Isotropic Radiated Power
EM
Electricity Meter
HALT
Highly Accelerated Life Test
IC
Integrated Circuit
ISM
Instrumentation, Scientific & Medical
IT
Information Technology
MIU
Meter Interface Unit
PIC
Programmable Intelligent Controller
ppm
Parts per million
PSR
Packet Success Rate
RF
Radio Frequency
ROI
Return On Investment
TBD
To Be Determined
UK
United Kingdom
US
United States of America
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 3 of 20
Company Confidential
TABLE OF CONTENTS
1.
1.1.
1.2.
2.
2.1.
3.
3.1.
3.2.
3.3.
3.4.
3.5.
4.
4.1.
4.2.
4.3.
5.
Introduction ..........................................................................................................................................5
General ..............................................................................................................................................5
Scope.................................................................................................................................................5
Product description .............................................................................................................................6
Ease of Installation.............................................................................................................................6
Environmental Specifications .............................................................................................................7
Storage Temperature Range..............................................................................................................7
Operational Temperature Range........................................................................................................7
Humidity.............................................................................................................................................7
Shock.................................................................................................................................................7
Vibration.............................................................................................................................................7
Mechanical Specifications...................................................................................................................8
Construction.......................................................................................................................................8
Packaging ..........................................................................................................................................8
Marking ..............................................................................................................................................9
Electrical Specifications ....................................................................................................................10
5.1.
5.2.
5.3.
Compatibility ....................................................................................................................................10
Power Supply...................................................................................................................................11
Pick-Up ............................................................................................................................................12
5.3.1.
MECHANISM ..........................................................................................................................12
5.3.2.
ACCURACY ...........................................................................................................................12
5.3.3.
TAMPER DETECTION ..............................................................................................................12
5.4.
Radio ...............................................................................................................................................13
5.4.1.
TRANSMIT CARRIER FREQUENCY ............................................................................................13
5.4.2.
ANTENNA ..............................................................................................................................13
5.4.3.
TRANSMISSION INTERVAL .......................................................................................................13
6.
Interface specifications .....................................................................................................................14
6.1.
Meter Interfaces ...............................................................................................................................14
6.1.1.
POWER .................................................................................................................................14
6.2.
ConFigIT Interface ...........................................................................................................................14
6.2.1.
HARDWARE ...........................................................................................................................14
6.2.2.
USE......................................................................................................................................14
7.
7.1.
7.2.
Regulatory Compliance .....................................................................................................................15
System Integration ...........................................................................................................................16
Meter Compatibility ..........................................................................................................................16
8.
Overview .............................................................................................................................................17
8.1.
Production Process Flow .................................................................................................................17
8.1.1.
THE FOLLOWING PROCESS FLOW CHART SHOWS THE EXPECTED ROUTE TO ACHIEVE THE
INSTALLING, TESTING AND CONFIGURING SEQUENCE OF THE EM MIU INTO VARIOUS RETROFIT METERS: .......17
8.2
METER PREPARATION ................................................................................................................18
8.2.1
ALL RECEIVED METERS ARE TO HAVE THEIR SERIAL NUMBERS RECORDED AS PER EXISTING
PROCEDURES. ........................................................................................................................................18
8.3
DISK MARKING ..........................................................................................................................19
Part No. xxxxxxxx XX xx
1.
Document Title
INTRODUCTION
1.1.
General
This document is intended to provide detailed information required by an AMR
Meter Shop for the integration of AT RAMAR’s 900 series Electric Meter (EM)
TransPondIT Meter Interface Unit (MIU) product for single phase domestic
electricity meters in the US.
1.2.
Scope
This document describes the 900 series EM TransPondIT MIU and provides the
necessary level of detail to enable the meter shop to install, test and deliver the
product ready for use by the customer.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 5 of 20
Company Confidential
Part No. xxxxxxxx XX xx
2.
Document Title
PRODUCT DESCRIPTION
TransPondIT allows the utility to receive data from its meters remotely. The
TransPondIT collects data from the meter and transmits it to a data collection device,
which may be mobile or fixed. In addition, the TransPondIT is capable of detecting
reverse rotation and will transmit an alarm indication if there is doubt about the
validity of the reading. The TransPondIT can be read by the following RAMAR
products: HandTrackIT, FastTrackIT, or CellTrackIT with no change to the
TransPondIT.
The TransPondIT can be fitted or retro-fitted in minutes to the meter.
Only qualified and properly trained personnel should attempt the installation of the
EM MIU.
2.1.
Ease of Installation
EM MIU units will be installed in two different settings; either with new meters at the
meter manufacturer’s plant or in approved meter shops that rework and calibrate
existing meters. It is a design criteria that the MIU be capable of being mounted in
a meter at point of meter calibration without additional tests other than ConFigIT to
confirm PSU connection and to load mechanical register data into electronic
register.
Mounting of the MIU in the meter takes similar time to that of mounting the lower
faceplate plus some time for connection of the power wires.
Mounting of the EM MIU within the electricity meter is simple with minimal operator
training required assuring proper installation and configuration settings by meter
shop employees or field personnel. Field personnel perform configuration of
account numbers at the end-user’s site with the EM ConFigIT device.
Clearing of tamper register in field is performed using ConFigIT.
Caution:
Changes or modifications not expressly approved by Advanced Technology
RAMAR Ltd could void the user’s authority to operate the equipment.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 6 of 20
Company Confidential
Part No. xxxxxxxx XX xx
3.
Document Title
ENVIRONMENTAL SPECIFICATIONS
3.1.
Storage Temperature Range
The temperature range for long-term storage of the MIU in un-powered state is to be -10ºC
to +50ºC.
The temperature range allowed for transport of the MIU in un-powered state is between
-40ºC to +85ºC.
Note: The MIU should not be held in the extended temperature range for transport for
more than 30 days.
3.2.
Operational Temperature Range
The operational temperature range of the MIU shall be -40ºC to +50ºC with occasional
excursions to +85ºC.
3.3.
Humidity
The non-condensing relative humidity shall be 5% to 95%.
3.4.
Shock
The MIU when mounted in meter is to survive Transportation drop test – ISTA Test
Procedure 1A
3.5.
Vibration
The MIU when mounted in meter is to survive Transportation Vibration test – ISTA Test
Procedure 1A.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 7 of 20
Company Confidential
4.
MECHANICAL SPECIFICATIONS
4.1.
Construction
The MIU is designed so that it fits all of the meter types listed with a minimal set of
adaptor hardware.
The product is fitted in the location of the meter lower faceplate, utilising the existing
mounting stand-offs.
The MIU is enclosed in a plastic enclosure to provide protection in handling and
against direct sunlight.
Torque specifications will be provided for attachment fixings to ensure a reliable
installation.
The design avoids any requirement for alignment of pickup at time of installation.
No meter calibration points are obscured.
4.2.
Packaging
Packaging has been developed and tested to ensure that damage does not occur to
the product during normal freight handling. There shall be 48 or 96 units per
package.
Part No. xxxxxxxx XX xx
4.3.
Document Title
Marking
The MIU marking is to include:
•
ATL RAMAR UK logo
•
Part code
•
FCC approval identifier
•
Canadian approval identifier
•
Serial number (with 128C bar code)
•
Mains input voltage and frequency
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 9 of 20
Company Confidential
5.
ELECTRICAL SPECIFICATIONS
5.1.
Compatibility
The unit operates in the same ISM band as the water TransPondIT products.
Furthermore, the EM is compatible with the following reading systems:
•
HandTrackIT
RR915/F-01-013 to RR915/F-01-04
•
FastTrackIT
FR915-01-01
Part No. xxxxxxxx XX xx
5.2.
Document Title
Power Supply
The unit takes mains power from the supply side of the meter.
No batteries are required.
The input voltage range over which the product must be able to read disk and send
transmissions is 100 – 260Vac.
Protection is provided so that the unit will survive the overvoltages and voltage
surges defined in ANSI C12.1.
There is no loss of configuration or meter reading data after power surge, brownout
or interrupt.
Power-line noise as defined in ANSI C12.1 does not adversely affect the unit.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 11 of 20
Company Confidential
The unit is appropriately protected to prevent the possibility of fire damage to a
residence.
Any hazardous voltage points have been protected to avoid accidental contact
during manufacture, service or calibration of the meter.
The average power consumption of the unit shall be less than 1.0W.
5.3.
Measurement Technique
5.3.1.
Mechanism
Electricity usage is measured by detecting rotation of the Ferraris disc. The
detection mechanism is frictionless and does not alter the balance of the disc.
The mechanism will restart regardless of disc position.
The detection mechanism will operate in ambient light levels of up to 100,000lux.
Reverse rotation is detected and causes the register to be decremented so that the
electronic register will match the mechanical register.
For meters where there is no suitable mark provided, the kit provided by the meter
shop shall include a mechanism for providing a black mark on disc that will not peel
off. The specifications of this mark are included in this document.
5.3.2.
Accuracy
The electronic register is to reflect disc rotations to accuracy of better than 0.05%.
5.3.3.
Tamper detection
The value in a tamper register shall be indicated in the following circumstances:
•
if the circuit detects an internal fault
•
if the sensor is disabled or
•
if the rotation of the Ferraris disc is reversed (the design is to incorporate a
separate register to record reverse rotation).
Clearing of the tamper events is to be performed on site using ConFigIT.
5.4.
Radio
Operational Range
The operational range is at least 300m in open field to a production HandTrackIT
held at height of 1.5m.
5.4.1.
Transmit Carrier Frequency
The nominal transmission frequency shall be 919.8976MHz.
5.4.2.
Antenna
The antenna is integral to the TransPondIT located within the glass case of the
electricity meter and does not hinder the installation of the product or obscure the
manually read dials, calibration screws or face-plate.
5.4.3.
Transmission Interval
The transmit interval is configurable from 5 seconds to 10 hours.
Part No. xxxxxxxx XX xx
6.
Document Title
INTERFACE SPECIFICATIONS
6.1.
Meter Interfaces
6.1.1.
Power
Mains power input.
6.2.
ConFigIT Interface
6.2.1.
Hardware
The Electric TranspondIT MIU is interfaced to ConFigIT from outside the glass via a
bi-directional optical port that is active when the MIU is powered.
6.2.2.
Use
a.
In Meter Retrofit Shop or in Meter Factory
The following actions can be performed:
• Enter mechanical meter reading
• Enter rotation rate
• Enter utility code
b.
At meter site
The following actions canl be performed:
• Customer number
• Clear tamper
• Readout of all registers including ID, all settings and status
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 14 of 20
Company Confidential
7.
REGULATORY COMPLIANCE
Fitting a meter with the MIU does not invalidate its compliance with the following:
a.
ANSI C12.1 – 2001
American National Standard for Electric Meters
(covers performance aspects)
b.
ANSI C12.10 – 1997 American National Standard for Watthour Meters
(covers environmental and physical aspects)
c.
CFR47 Part 15 (Note – declared as Class B Digital Device), Part A General,
Part C Intentional Radiator
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio or television reception,
which can be determined by turning the equipment on and off, the user is
encouraged to try to correct the interference by one or more of the following
measures:
--Reorient or relocate the receiving antenna
--Increase the separation between the equipment and receiver
--Consult the dealer
Part No. xxxxxxxx XX xx
Document Title
7.1.
System Integration
Installation Tools and techniques should consider methods such as bar-code scanners to
allow proper configuration and accuracy of information. Seamless integration into existing
IT systems is to be a design aim.
7.2.
Meter Compatibility
The EM MIU is compatible with electricity meters listed in Table 1.
Table 1. Compatibility includes all interfaces such as mechanical, electrical, magnetic and
optical.
Manufacturer
Model
Number
Voltage
Rotations
per kWH
Form
Factor
I-70-S/2
240Vac
7.2
2S
Siemens/Landis&Gyr
MX
240Vac
7.2
2S
ABB
AB1
240Vac
7.2
2S
General Electric
Table 1: List of Compatible Electricity Meters
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 16 of 20
Company Confidential
Part No. xxxxxxxx XX xx
8.
Document Title
OVERVIEW
8.1.
Integration Process Flow
8.1.1.
The following process flow chart shows the expected route to
achieve the installing, testing and configuring sequence of the EM MIU into
various retrofit meters:
Meters
Received
Palletised in multiples of
48/96.
Record Serial No.’s
Prepare
meters
Remove covers and
store.
Clean meters.
Inspect for damage, then
zero meter.
Clean Disk
and apply
Marker
Fit Potential
Clips
Select correct
Fixing Kit
Install Module
Modules
Shipped from
CEM/UK
Modules
Received
Packaging to be
determined by ATR, in
quantities of 48/96 or
multiples of.
Modules to be inspected
for damage to enclosure
and antenna.
Record Serial No.’s
Paint/Decal marker to be
sourced by meter house
and spec’d by ATR.
Cable Assembly – Parts to be sourced
by meter house.
ATR to specify Molex connector.
Specific drawings/part numbers to be
available to ATR.
3 Meter Types – Meter House
to source longer screws per
type and pillars (L&G).
ATR to spec pillar length.
Install with longer screws and pillars
(L&G only). Connect potential clips.
Refit meter nameplate.
Required tooling to be provided by
Meter House.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 17 of 20
Company Confidential
Part No. xxxxxxxx XX xx
Test and
Calibrate
Document Title
Test Spec to be defined
by ATR.
Meter test and
calibration procedure as
per Meter House spec.
Program
/Configure
Module
Hand Held ConFigIT to
be supplied with spec
and procedures by ATR.
Record Test
Data
Software to be
compatible with Meter
House tracking database
– Information Required
Box and
Palletise
Meters to be resealed.
Final Inspection.
Serial No.’s scanned.
Ship/Store
8.2 Meter Preparation
8.2.1 All received meters are to have their serial numbers recorded as per existing
procedures.
8.2.2 Covers are to be removed, cleaned and stored.
8.2.3 Meters are to be inspected for any damage as per existing Meter House criteria.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 18 of 20
Company Confidential
Part No. xxxxxxxx XX xx
Document Title
8.3 Disk Marking
8.3.1 The disk marking method will be determined by customer request, be it paint or
decal. It must meet the following criteria:
i)
There is minimum of a 20mm width apparent at the optical centres.
(Suggested dimensions as per drawing 52000501 iss C)
ii)
The material must have no magnetic susceptibility or effect.
iii)
The material must have 99.98%, or greater, absorption of
electromagnetic radiation having a wavelength of between 300 and
1200nm (UV, visible and IR light).
8.3.2 The marking method used will be as per Meter House current procedures and must
ensure that no damage or stress is caused to the Ferraris Disk is any form.
8.4 EM MIU Installation
8.4.1 The EM MIU is to be installed to the various meter types, as per Table 1, using the
appropriate fixing kit as sourced by the Meter House.
8.4.2 The kit will consist of longer screws of the same thread size as the existing ones
used to mount the lower faceplate to the standoff pillars.
8.4.3 In the case of any meter type not having standoff pillars high enough to support the
EM MIU in its correct position (such as the L&G MX), additional pillars are to be
sourced and fitted (L&G MX pillars to be 20mm long).
8.4.4 The Meter House will source the cable assembly used to connect the EM MIU to
the bus-bar supply. Specification for the cable to board connector will be provided
by the ATR.
8.4.5 The Meter House shall supply tooling required to install the EM MIU.
8.5 Test and Calibration
8.5.1 EM MIU to be tested iaw Test specification and procedures supplied by ATR.
8.5.2 Meter to be calibrated as per Meter House procedures.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 19 of 20
Company Confidential
Part No. xxxxxxxx XX xx
Document Title
8.6 Configuration
8.6.1 The EM MIU is to be configured using the handheld ConFigIT supplied with relevant
software and procedures by ATR.
8.6.2 The following steps are to be performed at the Meter House:
8.6.2.1
i) Clear Tamper
ii) Enter mechanical meter reading
iii) Enter rotation rate (as per Table 1)
iv) Enter utility code
8.7 Quality
8.7.1 The Meter House shall continue to work to their current quality specifications.
8.7.2 Specific standards/criteria shall be supplied by ATR if required.
Meter Shop Processes
© Advanced Technology RAMAR Ltd
Page 20 of 20
Company Confidential

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2002:10:10 09:17:51-04:00
Modify Date                     : 2002:10:10 09:17:51-04:00
Page Count                      : 20
Creation Date                   : 2002:10:10 13:17:51Z
Mod Date                        : 2002:10:10 13:17:51Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : RSeay
Metadata Date                   : 2002:10:10 13:17:51Z
Creator                         : RSeay
Title                           : Microsoft Word - EM915 manual.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MS8EM915V1

Navigation menu