Blum Novotest TCA Measuring Probe User Manual 306000011S EN V3

Blum Novotest GmbH Measuring Probe 306000011S EN V3

UserMan

Download: Blum Novotest TCA Measuring Probe User Manual 306000011S EN V3
Mirror Download [FCC.gov]Blum Novotest TCA Measuring Probe User Manual 306000011S EN V3
Document ID1497495
Application IDEmwolpNW8zgVqOcoCq8elw==
Document DescriptionUserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.93kB (611578 bits)
Date Submitted2011-07-08 00:00:00
Date Available2011-07-08 00:00:00
Creation Date2011-05-02 17:41:16
Producing SoftwareGPL Ghostscript 9.0
Document Lastmod2011-05-02 17:41:16
Document Title306000011S_EN_V3
Document CreatorPDFCreator Version 1.2.0
Document Author: Haefele

TC60 | TC63-30
Touch probe
Workpiece measurement
Radio transmission
Multidirectional
Wear-free measuring mechanism
Modular system
Batch- & mass production
Contour measurement
Axes compensation
–
Operating instructions
English
Type
P03.6000-010 | P03.6300-010
focus on productivity
Content
1. Safety Rules .................................................. 4
2. System Overview .............................................. 5
2.1 Display Elements...................................................................................................5
2.2 Tool Holder ............................................................................................................7
2.3 Technical Data .....................................................................................................8
2.4 Complete System.................................................................................................9
3. Mounting and Commissioning ................................... 10
3.1 Batterie einsetzen / wechseln..........................................................................10
3.2 Mounting of the Tool Holder ............................................................................11
3.3 Mounting of the TC76-T .....................................................................................12
3.4 Mounting of the Stylus .......................................................................................13
3.5 Cranked Styli (TC63-30/TC76)...........................................................................14
3.6 Display Basic Adjustments ................................................................................15
3.7 Programming of the Basic Adjustments .........................................................16
3.8 Probe Pairing.......................................................................................................18
3.9 Switch-on Probe (via radio receiver) .............................................................18
4. Maintenance ................................................ 18
4.1 Cleaning of the transparent ring.....................................................................18
4.2 Exchange of External Bellows ..........................................................................19
5. Trouble Shooting ............................................. 21
6. Order Numbers .............................................. 22
7. Shipping Instructions / Storage .................................. 25
8. Radio Approval .............................................. 26
(P03.6600-000.011)
 Installation instructions radio receiver RC66
 Installation instructions interface IF59-A2
(P03.5900-000.011)
 Programming instructions Blum measuring cycles
(P03.8000031.305L/360L)
P03.6000-000.011S
306000011S_EN.docx
 by Blum-Novotest 2010
02.05.2011 version: V1A
Original operating instructions
Subject to technical change without any
notice
Safety Rules
Zeichenerklärung:
CAUTION
Important advice for appliance protection
Advice to secondary literature
Additional advice
LED shines
GN
GN Green
RD Red
GN
BU Blue
LED flashes
OG Orange VT Violet
Abbreviations:
BTH Blum Tool Holder
Md Tightening Torque
LF: Low Force
1. Safety Rules
Important advice for appliance protection:
CAUTION
•
Handle probe like a precision tool.
•
Keep the probe clean.
•
Mount the probe in assigned tool holders only.
•
Battery: Please insert before operating!
•
Protect the probe by using programmed maximum travel.
•
Ensure that adequate safety regulations as well as safety
interlockings are kept.
•
Damaged styli are not reusable.
 by Blum-Novotest 2010
System Overview
2. System Overview
2.1 Description
10
(1)
Shaft for tool holder BTH
(2)
Centering screws
(3)
Battery cover
(4)
Battery
(5)
Hall sensor MODE
(6)
Hall sensor SET
(7)
LED Status
(8)
Measuring mechanism
(9)
Stylus
(10)
Pin hole
Fig. 2.1
3 pcs.
2.2 Display Elements
Colour
LED Status (7)
Standby
GN GN GN GN
Stylus initial position
RD RD RD RD
Stylus deflected
GN BU GN BU
Stylus initial position - battery low
RD BU RD BU
Stylus deflected - battery low
RD
Battery low
Fig. 2.2
 by Blum-Novotest 2010
System Overview
TC60
TC63-30
Ø63
Ø28
Ø28
24
24
Ø63
113
100
TC63-30
10
TC76-T
Ø25
15°
15°
X/Y
X/Y
Fig. 2.3
Stylus length
(mm)
Max. deflection X/Y (mm)
TC60
TC63-30/ TC76
30
14
12
50
19
17
75
26
24
100
32
30
150
44
200
57
Tab. 2.1
 by Blum-Novotest 2010
System Overview
2.3 Tool Holder
Type
Order number
System BTH 50(TC60/63-30)
HSK-A 40
57
P03.8000-035.140A
HSK-A 50
63
P03.8000-035.150A
HSK-A 63
50
P03.8000-035.163A
HSK-A 80
55
P03.8000-035.180A
HSK-A 100
60
P03.8000-035.100A
HSK-E 40
57
P03.8000-035.140E
HSK-E 50
63
P03.8000-035.150E
HSK-E 63
50
P03.8000-035.163E
SK 30
60
P03.8000-035.230
SK 40
50
P03.8000-035.240
SK 50
24
P03.8000-035.250
MAS-BT 30
50
P03.8000-035.330
MAS-BT 40
50
P03.8000-035.340
MAS-BT 50
40
P03.8000-035.350
Tab. 2.2
CAUTION
Coolant
Pls. use coolant pipe for tool holder HSK for machining centers
with internal coolant supply.
Type
System BTH 50
HSK 25
P03.8000-035.125K
HSK 32
P03.8000-035.132K
HSK 40
P03.8000-035.140K
HSK 50
P03.8000-035.150K
HSK 63
P03.8000-035.163K
HSK 80
P03.8000-035.180K
HSK 100
P03.8000-035.100K
Tab. 2.3
 by Blum-Novotest 2010
System Overview
2.4 Technical Data
TC60
Approach direction
Measuring force XY-direction
Measuring force Z-direction
Max. deflection XY
Max. deflection Z
Trigger point XY
Trigger point Z
Max. acceleration
Repeatability**
Max. probing speed
Weight
Protection class
Signal transmission
Frequency band
Transmission power
Operating range
Battery life
Tool holder HSK–SK-BT
Storage temperature
Operating temperature
TC63-30 / TC76-T
± X, ±Y, -Z
± X, ±Y, ±Za
2 N**
1,3 N***
7N
5,9 N
± 15°
± 15°
10 mm
5 mm
------------2
50 m/s
50 m/s2****
1 µm 2σ
1 µm 2σ
3 m/min
2 m/min
970 g
680 g (TC63-30)
IP 68
Funk
2,4000 – 2,4835 GHz
0 dBm
15 m
Ultralife Lithium 6LR61 (9V)
BTH 50
-20 °C ... +70 °C
+5 °C ... +50 °C
** Stylus L=50 mm
*** Stylus L=30 mm
**** with accessories (e.g. extension, angle): max. acceleration 10 m/s2
a)
see chap.3.5
LF: Low Force
Tab. 2.4
 by Blum-Novotest 2010
System Overview
2.5 Complete System
TC60
TC63-30
RC66
IF59 - A2
Aux
Z-Nano
Fig. 2.4
RC66:
⇒ switch ON/OFF via radio signal
⇒ signal transmission for TC series
 Installation instructions RC66 (P03.6600-000.011)
 Installation instructions IF59-A2 (P03.5900-000.011)
 by Blum-Novotest 2010
Mounting and Commissioning
3. Mounting and Commissioning
3.1 Batterie einsetzen / wechseln
Empfohlener Batterietyp:
Type
Ultralife Lithium U9VL-J
mAh
1200
Contin.
operation
ca. xxx h
5% Use
ca. xxx Tage
Standby
ca. xxx Tage
Order number
980702003
Dispose batteries acc. to legal requirements.
CAUTION
Risk of short-circuit
Be careful to correct position of gasket.
Keep battery space clean and dry.
1.
Clean probe carefully and remove battery cover
2.
Exchange battery - take care of polarity!
3.
Install battery cover straight (check O-Ring and grease if necessary)
4.
Automatic display of the basic adjustments (chap. 3.6)
Fig. 3.1
10
 by Blum-Novotest 2010
Mounting and Commissioning
3.2 Mounting of the Tool Holder
1. Insert probe into tool holder (System BTH 50)
2. Tighten screw slightly only
3. Mount stylus (see chap. 3.4)
4.
5.
6.
7.
Insert probe into spindle
Turn probe by 360°
Observe display of run-out – stylus is not allowed to be deflected.
Adjust concentricity by crosswise loosening and tightening of the opposite
center screws (4 internal hexagon screws 2 mm) - Md < 2 Nm
Run-Out:
< 10 µm
8. Tighten holding screw (Md = 12 Nm)
9. Carry out calibration cycle
TC60/TC63-30:
2 mm
Md < 2 Nm
Fig. 3.2
 by Blum-Novotest 2010
11
Mounting and Commissioning
3.3 Mounting of the TC76-T
Md = 10 Nm
Fig. 3.3
(C)
hook wrench (scope of delivery)
Mounting of the extension / angle: see referring data sheet
12
 by Blum-Novotest 2010
Mounting and Commissioning
3.4 Mounting of the Stylus
CAUTION
Damage of the measuring mechanism
•
TC60: When mounting the stylus into the probe, it is
absolutely necessary to lock the probe with the mounting
tool B to avoid torsion of the measuring mechanism.
•
TC63-30 / TC76:
When mounting the stylus into the probe, it is absolutely
necessary to use the interlocking disk (A) (backlash-free).
Pls. take care of the orientation of the interlocking disk (A)
(top side = top)
•
Calibrate probe after mounting of stylus!
•
Damaged styli are not reusable!
1,5 mm
Md = 1 Nm
TC60
TC63-30
Fig. 3.4
(A)
interlocking disk (scope of delivery)
(B)
mounting tool (scope of delivery)
 by Blum-Novotest 2010
13
Mounting and Commissioning
3.5 Cranked Styli (TC63-30/TC76)
CAUTION
Damage of the measuring mechanism
Pay attention to area of operation and max. overtravel
Z+
Fig. 3.5
Fig. 3.6
Fig. 3.7
Fig. 3.8
14
 by Blum-Novotest 2010
Mounting and Commissioning
3.6 Display Basic Adjustments
1. Remove battery
2. Insert battery
3. Automatic display of the
basic
adjustments:
First colour:
MODE
Second colour:
SET
Wait 30
sec.
MODE
RD
OG
BU
RD
SET
Transmission mode
GN
Normal*
(3x MODE – SET)
RD
Robust
BU
Fast
Switch-on time
BU
Fast
(3x MODE – SET)
GN
Normal*
RD
Slow
Battery capacity
GN
O.K.
(3x MODE – SET)
RD
low
Battery low
* Standard
 by Blum-Novotest 2010
15
Mounting and Commissioning
3.7 Programming of the Basic Adjustments
In this mode the basic adjustments can be set.
1. Remove Battery
2. Insert Battery
(Polarity!)
3. Activate programming mode
during display phase
(MODE):
wait 30
sec.
4. Change adjustments (SET)
hold magnetic pin
on inscription SET
16
5. Menu change (MODE)
hold magnetic pin
on inscription MODE
 by Blum-Novotest 2010
Mounting and Commissioning
Activate programming sequence:
MODE
RD
SET
Transmission
Mode
GN
Normal
•
standard adjustment
RD
Robust
•
ambient conditions with
radio interferences
high chip pollution
•
OG
Switch-on
time
BU
Fast
•
•
fast measuring speeds
interference-free ambient
conditions
BU
Fast
•
•
fast switch-on time
setting decreases battery life
GN
Normal
•
•
normal switch-on time
standard setting
RD
Slow
•
•
•
low switch-on time
setting increases battery life
not suitable for switch on/of
impulse controlled
Automatic display of the basic adjustments
Standby
 by Blum-Novotest 2010
17
Maintenance
3.8 Probe Pairing
 Installation instructions IF59-A2 (P03.5900-000.011)
3.9 Switch-on Probe (via radio receiver)
Optical by e.g. M-Code
 Installation instructions RC66 (P03.6600-000.011)
 Installation instructions IF59-A2
(P03.5900-000.011)
4. Maintenance
•
•
•
The
probe
needs
maintenance only
Keep the glass ring clean
Check bellows for damages
minimum
4.1 Cleaning of the transparent ring
CAUTION
18
Please do always use mild detergents (e.g. neutral soap
solution or diluted washing-up liquid) for cleaning of the
transparent ring. Please do always use a soft, clean cloth to
clean.
Damage of the transparent ring
Please, do not use any detergents containing acetone,
alcohol, cleaning benzine or solvent! They can damage the
transparent ring.
Please, do not use any detergents containing abrasive
substances (e.g. scouring powder or cleansing milk. They can
damage the transparent ring!
 by Blum-Novotest 2010
Maintenance
4.2 Exchange of External Bellows
CAUTION
It is not allowed to exchange the internal bellows!
In case that it should be damaged, please send probe for
repair.
Damage of the measuring system
The measuring system is not allowed to be twisted!
TC76-LF (low force):
The bellows is allowed to be exchanged by Blum-Novotest
only!
1. Clean probe and remove stylus if necessary (chap.3.4), while using the
interlocking disk (A) resp. mounting tool (B).
2. Remove front ring (16) with mounting tool (B).
3. Remove external bellows carefully (13), without twisting the measuring
mechanism (10).
4. Grease new bellows (13) at the contact surface to the groove slightly
(grease: ISOFLEX TOPAS NB 52 or STABURAGS NBU30).
5. Install new bellows (13), without twisting the measuring mechanism.
The bellows must click to the groove on the measuring system.
Please take care of plane supporting surface of the bellows.
6. Install front ring (mounting tool (B)).
7. Mount stylus while using the interlocking disk (A) resp. mounting tool (B).
8. Carry out calibration cycle.
 by Blum-Novotest 2010
19
Maintenance
Fig. 4.1 TC60
Fig. 4.2 TC63-30 / TC76
(10)
Measuring mechanism
(14)
Centering ring
(10a
Groove
(15)
Internal bellows
(13)
External bellows
(16)
Front ring
20
 by Blum-Novotest 2010
Trouble Shooting
5. Trouble Shooting
Error
Possible cause
Countermeasures
LED Status flashes
resp. LED light
unsteady
Battery is low
Check batteries and exchange them if
possible
LED Status shines red
Battery is weak
Exchange batteries
LED Status changes
from green to violet
while inserting the
batteries without
deflecting the stylus
resp.
LED Status flashes red
No pressure
com-pensation
after transport by
airfreight
Provide pressure compensation:
1. Remove cover from battery box
2. Loosen thread pin (3a), approx. 2
revolutions
3. Deflect stylus shortly in Z-direction,
wait for approx. 1 minute
4. Then tighten thread pin again
5. Fit battery box cover precisely and
mount it
Battery is empty
Insert new batteries
Probe is outside
of the
transmission
range
Check transmission range between RC66
and TC60
No pairing of the
probe on IF59-A2
Check pairing
Probe is outside
of the
transmission
range
Check transmission range between
receiver and probe
Radio error
signals in
transmission
range
Find and clear radio error signals
Control sends signal
„deflected“ without
deflecting the stylus
No activation of the
probe is possible
LED Status flashes
white
 by Blum-Novotest 2010
Check adjustment of transmission power
(TC60 and IF59-A2)
21
Order Numbers
6. Order Numbers
Werkzeugaufnahme
BTH 50
See chap. 2
Probe TC60
Basic system TC63-30
P03.6000-010-A1
P06.6300-030-A1
Spare and wear parts
Spare and wear parts are not subject to warranty.
Bellows for TC60
P03.8000-020.002
Bellows for TC76
P03.8000-020.010
Battery for Probe TC60 / 63-30
Type Ultralife Lithium U9VL-J-9V
1200mAh
980702003
Accessory set for TC60
P03.8000-020.001
Accessory set for TC63-30
P03.8000-020.013
Accessory set for TC76
P03.8000-020.012
22
9V
9V
 by Blum-Novotest 2010
Order Numbers
Styli for probe TC60
Ceramic
Carbide
 by Blum-Novotest 2010
Length
Ø
50 mm
2 mm
4 mm
5 mm
6 mm
P03.8000-010.050.02
P03.8000-010.050.04
P03.8000-010.050.05
P03.8000-010.050.06
75 mm
6 mm
P03.8000-010.075.06
100mm
2 mm
3 mm
4 mm
5 mm
6 mm
P03.8000-010.100.02
P03.8000-010.100.03
P03.8000-010.100.04
P03.8000-010.100.05
P03.8000-010.100.06
150 mm
4 mm
6 mm
P03.8000-010.150.04
P03.8000-010.150.06
200 mm
6 mm
P03.8000-010.200.06
250 mm
6 mm
P03.8000-010.250.06
300 mm
6 mm
P03.8000-010.300.06
Length
Ø
50 mm
3 mm
4 mm
5 mm
6 mm
P03.8000-012.050.03
P03.8000-012.050.04
P03.8000-012.050.05
P03.8000-012.050.06
100 mm
4 mm
5 mm
6 mm
P03.8000-012.100.04
P03.8000-012.100.05
P03.8000-012.100.06
23
Order Numbers
Styli for probe TC76
Ceramic
Length
Carbide
Ø
50mm
2 mm
4 mm
5 mm
P03.8000-020.050.02
P03.8000-020.050.04
P03.8000-020.050.05
75 mm
5 mm
P03.8000-020.075.05
100 mm
5 mm
P03.8000-020.100.05
Length
Ø
30 mm
2 mm
3 mm
4 mm
5 mm
P03.8000-022.030.02
P03.8000-022.030.03
P03.8000-022.030.04
P03.8000-022.030.05
50mm
3 mm
4 mm
5 mm
6 mm
P03.8000-022.050.03
P03.8000-022.050.04
P03.8000-022.050.05
P03.8000-022.050.06
75 mm
5 mm
P03.8000-022.075.05
100 mm
5 mm
P03.8000-022.100.05
Styli for probe TC76
Adapter
Tasteinsatz / stylus
Adapter
Stylus
24
P03.8000-025.300
Länge
□
27 mm
30 mm
36 mm
47 mm
52 mm
62 mm
77 mm
Q6
Q6
Q6
Q6
Q6
Q6
Q6
P03.8000-025.342
P03.8000-025.341
P03.8000-025.343
P03.8000-025.340
P03.8000-025.345
P03.8000-025.344
P03.8000-025.346
 by Blum-Novotest 2010
Shipping Instructions / Storage
7. Shipping Instructions / Storage
•
•
•
•
•
•
 by Blum-Novotest 2010
If the probe should be stored for a longer period, please
remove the battery from the battery box.
If you return the probe for repair, please enclose a detailed
error description and the probe certificate.
The probe is to be returned in the original packing only.
The packing is not allowed to deflect the probe, neither in
X/Y- nor in Z-direction.
Tool holder and battery are to be removed before packing.
The probe should be packed shock and pollution
protected.
25
Radio Approval
8. Radio Approval
Area:
Radio Approval:
Europe:
0681
Japan:
Regulations:
EN 300 328 V1.4.1,
EN 301 489-17 V1.2.1,
EN 60950-1:2001
202WW10568411
“This device has been granted a designation number by Ministry of
Internal Affairs and Communications under „Ordinance concerning
Technical Regulations Conformity Certification etc. of Specified Radio
Equipment (特定無線設備の技術基準適合証明等に関する規則)“ Article
2-1-19.
USA:
FCC ID: ZCQRCA
FCC Part 15
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
The antenna(s) used for this transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
Canada:
IC:9570A-RCA
Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device
must accept any interference, including interference that may cause
undesired operation of the device.
This device and its antenna(s) must not be co-located or operating in
conjunction with any other antenna or transmitter.
This equipment complies with IC Canada RF radiation exposure limits
set forth for an uncontrolled environment as per RSS-102 Issue 4.
26
 by Blum-Novotest 2010
EC Declaration of Incorporation
acc. to the EC Machine Regulations 2006/42/EC in the edition from 17 May.2006
We hereby confirm that the subsequently following components are defined for the
installation into other machines and that they are in accordance with the following
safety requirements of the EC regulations.
Commissioning is not allowed until it is ascertained that the machines, in which the
components are installed, are in accordance with the EC regulations 2006/42/EC.
The relevant technical information is compiled acc. to annex VII part B and, where
appropriate, we will send the information concerning the components to the different
countries. The industrial property rights of Blum-Novotest GmbH will remain unaffected.
Component name:
Safety requirements
2006/42/EG, Annex I
Applied standards:
EC-Regulations:
P03.6000 / P06.3300
Probe for workpiece measurement
1.5.1
2004/108/EG
2006/95/EG
1999/5/EG
Applied harmonized standards:
EN61000-6
EN60204-1
EN ISO 12100
EN 300 328
EN 301 489-17
EN 60950-1:2001
Applied national standards:
DIN VDE 0100
DIN VDE 0113
Authorised presentative for technical information:
Blum-Novotest GmbH
Kaufstr. 14
88287 Gruenkraut, Germany
 by Blum-Novotest 2010
27
Service Order
Please fill out completely this repair order and attach it to the system. This will
save you and us costs due to time-consuming inquiries and ensures a quick
repair.
Blum-Novotest GmbH
Kaufstr. 14, 88287 Gruenkraut/Gullen - Germany
Tel. +49 751 6008-0, Fax. +49 751 6008-156
Company:
Department:
Contact:
Address:
Phone:
Fax:
Email:
Probe Type, Serial No.:
Machine Type,
Manufacturer:
Description of Defect:
28
 by Blum-Novotest 2010
focus on productivity
Blum-Novotest GmbH
Kaufstr. 14
88287 Gruenkraut, Germany
Tel.:+49 751 6008-0
Fax:+49 751 6008-156
www.blum-novotest.com
vk@blum-novotest.com
Support
Hotline:
Vertrieb/sales:
Tel.:+49 751 6008-200
Service LaserControl :
Tel.:+49 751 6008-202
Service Messtaster/probes: Tel.:+49 751 6008-203
Blum-Novotest GmbH Prüftechnik
Willich, Germany
Tel. +49 2154 921970
KK Blum Laser Measuring Technology
Nagoya, Japan
Tel. +81 568 74-5311
Blum-Novotest Srl
Como, Italy
Tel. +39 031 283 955
Blum-Novotest
Shanghai, China
Tel. +86 21 52080480
Blum-Novotest Ltd.
Birmingham, England
Tel. +44 1543 257111
Blum Production Metrology Co., Ltd.
Taichung, Taiwan
Tel. +886 4 2358 3900
Blum Laser Measuring Technology Inc.
Cincinnati, USA
Tel. +1 859 3446789
Blum Production Metrology Pte. Ltd.
Singapore, Singapore
Tel. +65 62720998
Blum-Novotest Sarl
Bordeaux, France
Tel. +33 55702 0135
Blum-Novotest Ltd.
Soul, Republic of Korea
Tel. +82 2 2026-1300
Blum-Novotest s.r.o.
Kroměříž, Czech Republic
Tel. +420 573 330373
focus on productivity

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 29
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : 2e498db5-772e-11e0-0000-aa3dc7e1ddb7
Producer                        : GPL Ghostscript  9.0
Keywords                        : ()
Modify Date                     : 2011:05:02 17:41:16+02:00
Create Date                     : 2011:05:02 17:41:16+02:00
Creator Tool                    : PDFCreator Version 1.2.0
Document ID                     : 2e498db5-772e-11e0-0000-aa3dc7e1ddb7
Format                          : application/pdf
Title                           : 306000011S_EN_V3
Creator                         : Haefele
Description                     : ()
Author                          : Haefele
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZCQTCA

Navigation menu