BodyMedia MF Physiological monitoring device User Manual GSG minifly rev3 indd

BodyMedia, Inc. Physiological monitoring device GSG minifly rev3 indd

Users Manual

Download: BodyMedia MF Physiological monitoring device User Manual GSG minifly rev3 indd
Mirror Download [FCC.gov]BodyMedia MF Physiological monitoring device User Manual GSG minifly rev3 indd
Document ID896524
Application ID9gDAU0di7zbSRpuaciIrqw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize63.17kB (789641 bits)
Date Submitted2008-01-30 00:00:00
Date Available2008-03-15 00:00:00
Creation Date2007-08-29 09:44:38
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2007-08-29 09:44:38
Document TitleGSG-minifly-rev3.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: quang

100346_REV1
4 Smithfield Street
11th Floor
Pittsburgh, PA 15222
USA
P.412.288.9901
F.412.288.9902
www.bodymedia.com
© Copyright 2007 BodyMedia, Inc.
Getting Started
1
Legal Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Uploading Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Wearing the armband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Registration & Account Creation . . . . . . . . . . . . . . . . . . . . . . . . 18
Your SenseWear® armband. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Features of the SenseWear® armband . . . . . . . . . . . . . . . . . . . . . 12
PLACEHOLDER
The SenseWear® WMS
package includes:
• One (1) SenseWear®
armband
• One (1) standard wing/
strap assembly and one
(1) large size wing/strap
assembly
• One (1) USB cable
This product complies with the general requirements for a safe medical device.
However, this product alone is not meant to substitute for proper medical
diagnosis, care, or treatment.
This Getting Started Guide for SenseWear® WMS takes you step-by-step
through the set up of your system. It tells you how to configure and wear the
SenseWear® armband, and collect and retrieve data from your armband via the
SenseWear® WMS website. It is very important that you read and follow these
directions to ensure the accuracy of your data.
Welcome to the SenseWear® Weight Management Solution (WMS). The
SenseWear® solution will allow you to easily collect, manage, and analyze
physiological and lifestyle data. Please read and follow the instructions included in this guide before using the armband and WMS website.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 02
Important . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 03
introduction
table of contents
3
This EQUIPMENT not suitable for use in the presence of a FLAMMABLE ANAESTHETIC MIXTURE WITH AIR or WITH OXYGEN OR NITROUS OXIDE.
Do not get the device close to other devices that can cause electromagnetic
interferences of any nature.
This product is non-defibrillation proof.
This product complies with the general requirements for a safe medical device
under applicable directives. However, this product alone is not meant to
substitute for proper medical diagnosis, care, or treatment. Clinicians should
not make drastic changes to a user’s lifestyle based solely on data from the
armband. The SenseWear armband has been clinically validated for subjects
between 7 and 65 years of age who are engaged in resting, ambulatory, stationary biking, motoring and weight-lifting activities, etc. Due to metabolic variations, subjects who are 1) outside this age range or 2) engaged in alternate
or obscure activities may see decreased accuracy in the data. Any decisions
based on the data from this device should be made only by medical or paramedic personnel and should consider the condition and lifestyle of the subject
tested. The SenseWear® armband should not be used for life critical applications; improper usage may result in harm or even death to the wearer.
Please be sure to verify equipment is connected and used compliant to
UL1950.
Intended Use
The SenseWear® armband can be used as a monitor for applications such as:
nutritional diagnostics, metabolic diseases, pediatrics, pulmonary and cardiac
studies, geriatrics, internal medicine, occupational medicine, neurology, psychiatrics, sleep screening, and in general anywhere it is necessary to monitor
caloric and energy consumption, movement, physical activity, quality of life,
lifestyle, behavior and/or stress.
Be sure that both your arm and the sensors on the back of the armband are
cleaned daily. To clean the sensors, wipe with a soft, damp cloth. If you develop a rash where the armband comes in contact with your skin, discontinue
Wear comfortably
Be careful not to over-tighten the armband while on your arm. If, at any time,
you feel constriction or loss of circulation, simply loosen the adjustable strap
and re-fasten it to a more comfortable setting.
Keep the SenseWear® armband and wireless communicator out of reach of
children. Both products contain smaller, removable parts which can become
choking hazards.
The SenseWear® wireless communicator should not be used in airplanes,
hospitals or locations where cellular telephones or electronic devices are
prohibited.
The equipment or system should not be used adjacent to or stacked with
other equipment and if adjacent or stacked use is necessary, the equipment or
system should be observed to verify normal operation in the configuration in
which it will be used.
Medical electrical equipment needs special precautions regarding EMC and
needs to be installed and put into service according to the EMC information
provided on pages 8-11. Portable and mobile RF communications equipment
can affect medical electrical equipment.
important
important
5
Please note when submerging the armband in water:
Water resistance
The armband is not intended for long term operation under water. The armband is IP67 water resistant to 1 meter under water for 30 minutes. Loss of
data may occur if the armband is under water for a longer period of time.
Users with sensitive skin should avoid wearing the armband excessively. If you
have sensitive skin, remove the armband 1 hour for every 24 hours of wear
time to reduce potential for skin irritation.
When the armband is on the arm, DO NOT connect it to the USB cable.
There have been reports of scratches/cuts associated with the Velcro tab of the
strap. The Velcro tab should be aligned with the strap to avoid contact with the
skin. Also, excessively hot armbands, such as those left in a car in the summer,
may cause skin burns if they are not allowed to cool before use.
Check armband for sharp edges or damage before each use.
• Data accuracy may become compromised if the sensing module is
submerged in water.
• The wing seal must be in good condition and the wing must be properly
attached to the sensing module to avoid damaging the unit.
• Do not get the sensing module wet while removed from the wing assemble
as damage will occur.
use and consult your physician before continuing regular use of the armband.
The design of the armband involved many materials experts, physicians, and
suppliers who are familiar with wearable materials and products. Each material was chosen for its precedent in other skin contact products or has been
independently approved for skin contact. However, everyone’s skin is different
and wearers with very sensitive skin may experience irritation or redness after
wearing the armband. If this occurs, discontinue use and consult your physician. If you have known metals allergies, you should consult your physician
prior to wearing. Do not wear armband when open sores are present.
Maintenance
Do not attempt to open the armband yourself. It contains no user-serviceable
parts. Refer all servicing to qualified Service Personnel. Opening the armband
yourself will void the warranty.
Dispose of device in accordance with local, state, federal, or country specific
regulations.
To prevent possible damage to the USB cable, grasp the plug end when disconnecting the USB cable. Replace the cable if it becomes frayed.
Avoid exposing the armband to extreme temperatures, direct sunlight, moisture, sand, dust, or mechanical shock.
Handling
Though the SenseWear® armband was designed for wearability and long-term
use, it is a sensitive monitoring device. Rough handling can break internal
components. Never drop or shock the armband and always store it in a safe
place when not in use.
important
important
7
Disinfecting
Wipe back of armband with soft cloth dampened with 70% isopropyl alcohol.
Allow armband to dry for 5-10 minutes before wearing DO NOT STERILIZE
THIS UNIT.
Moisten a soft cloth or towel with mild disinfectant soap and water. Wipe and
dry the skin-touching side of the armband. Never use solvents to clean the
armband, only for disinfecting (see below). The adjustable strap should be
hand-washed with mild soap and warm water, then air-dried. Machine drying
should be avoided.
Cleaning
Always clean and dry the armband after vigorous sweating activities or when
it becomes noticeably moist or dirty. Failure to keep the armband clean, or
improper cleaning, may irritate the skin and affect the sensor performance.
Computer and Wireless Communicator
1.5m
Diagram not to scale.
1.5m
Class B, Group 1
N/A
N/A
Harmonics
IEC 6100-3-2
Flicker
IEC 6100-3-3
Compliance
RF Emissions
CISPR 11
Emissions Test
The Product MF is suitable for use in all establishments, including domestic, and those directly
connected to the public low-voltage power supply
network that supplies buildings used for domestic
purposes.
The Product MF uses RF energy only for its inernal
function. Therefore, its RF emissions are very low
and are not likely to cause any interference in
nearby electronic equipment.
2.5m
Electromagnetic Environment - Guidance
The Product MF (SenseWear® armband) is intended for use in the electromagnetic environment
specified below. The customer or user of the Product MF should ensure that it is used in such an
environment.
Guidance and Manufacturer’s Declaration - Emissions
1.5m
Patient Environment
Changes or modifications to this equipment not expressly approved by the
party responsible for compliance could void the user’s authority to operate
the equipment.
If the armband is dropped, ensure that it is working properly and not physically damaged before relying on readings.
important
important
9
Magnetic Field
IEC 61000-4-8
Power
Frequency
50/60Hz
N/A
>95% Dip for
0.5 Cycles
Voltage Dips/
Dropout
IEC 61000-4-11
3A/m
>95% Dip for 5
Seconds
30% Dip for 25
Cycles
60% Dip for 5
Cycles
N/A
±1kV Differential
±2kV Common
Surge
IEC 61000-4-11
3A/m
N/A
±2kV Mains
±1kV I/Os
EFT
IEC 61000-4-4
±6kV Contact
±8kV Air
Compliance
Level
±6kV Contact
±8kV Air
IEC 60601
Test Level
ESD
IEC 61000-4-2
Immunity Test
Power frequency magnetic fields should
be that of a typical commercial or hospital environment.
Mains power quality should be that of a
typical commercial or hospital environment. If the user of the Product MF requires continued operation during power
mains interruptions, it is recommended
that Product MF be powered from an
uniterruptible power supply or battery.
Mains power quality should be that
of a typical commercial or hospital
environment.
Floors should be wood, concrete, or
ceramic tile. If floors are synthetic, the
r/h should be at least 30%.
Electromagnetic
Environment - Guidance
The Product MF (SenseWear® armband) is intended for use in the electromagnetic environment
specified below. The customer or user of the Product MF should ensure that it is used in such an
environment.
Guidance and Manufacturer’s Declaration - Immunity
important
Radiated RF
IEC 61000-4-3
Conducted RF
IEC 61000-4-6
Immunity Test
3 V/m
80 MHz to
2.5 GHz
3 Vrms
150 kHz to
80 MHz
IEC 60601
Test Level
3 V/m
80MHz to
2.5 GHz
3 Vrms
150 kHz to
80 MHz
Compliance
Level
Interference may occur in the vicinity of
equipment containing a transmitter.
10
FIeld strengths from fixed transmitters,
as determined by an electromagnetic site
survey, should be less than the compliance levels (V1 and E1).
Where P is the max power in watts and D
is the recommended separation distance
in meters.
• D=(7/EI)(Sqrt P)
800 MHz to 2.5 GHz
• D=(3.5/E1)(Sqrt P)
80 to 800 MHz
• D=(3.5/V1)(Sqrt P)
Portable and mobile communications
equipment should be separated from
Product MF by no less than the distances
calculated/listed below:
Electromagnetic
Environment - Guidance
The Product MF (SenseWear® armband) is intended for use in the electromagnetic environment
specified below. The customer or user of the Product MF should ensure that it is used in such an
environment.
Guidance and Manufacturer’s Declaration - Emissions
important
11
0.3689
1.1666
3.6893
11.6666
0.1
10
100
11.6666
3.6893
1.1666
0.3689
0.1166
D=(3.5/V1)(Sqrt P)
D=(3.5/V1)(Sqrt P)
0.1166
Separation (m)
80 to 800MHz
Separation (m)
150kHz to 80MHz
0.01
Max Output
Power (Watts)
23.3333
7.3786
2.3333
0.7378
0.2333
D=(7/E1)(Sqrt P)
Separation (m)
800MHz to 2.5GHz
The Product MF (SenseWear® armband) is intended for use in the electromagnetic environment specified below. The customer or user of the Product MF can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF Communications Equipment and the
Product MF as recommended below, according to the maximum output power of the communications
equipment.
Recommended Separations Distances for the Product MF
important
12
Product specifications
Sensors:
• Accelerometer (3-axis)
• Heat Flux
• Skin Temperature
• Near-Body Temperature
• Galvanic Skin Response (GSR)
Materials:
• Monitor: ABS, polyurethane, co-polyester, 304 grade stainless steel
• Wireless Communicator: ABS
• Adjustable Strap: Nylon, polyester, Lycra (no latex content) or polyisoprene
Battery type: Internal lithium polymer cell battery
RF Frequency: 2.4GHz
Transmitter output power: <1mW
Battery power: about 7 days under use (18 hrs/day)
Memory capacity: about 10 days under use (18 hrs/day)
Monitor size: (l) 55mm x (w) 62mm x (h) 13mm [2.2” x 2.4” x 0.5”]
Monitor weight (with adjustable strap): TBD
Armband features
• Gathers raw physiological data including Movement, Heat Flux, Skin Temperature, Near Body Temperature, and Galvanic Skin Response.
• Contains approximately 7 days of battery life before needing to
be recharged.
• Stores approximately 10 days of continuous physiological and lifestyle
data.
• Offers sound feedback for Reminders and alerts.
• Wireless uploads available if data is sent to a PC via a wireless communicator.
features of the sensewear® armband
13
Skin Temperature
• Calibrated Range is 20.00ºC to 40.00ºC
• A minimum resolution of 0.05ºC
• Two standard deviation accuracy of +/- 0.80°C
Galvanic Skin Response
• Calibrated Range is 56KΩ to 20MΩ (50.00 nSiemens – 17.00 uSiemens)
• Two-standard-deviation accuracy of +/- 7.00 nSiemen up to 233.34 nSiemens reading
• Two-standard-deviation accuracy of +/- 3.00% of expected value otherwise
Heat Flux
• Calibrated Range is 0.00 W/m2 to 300.00W/m2
• A minimum resolution of 1.00W/m2
• Two-standard-deviation of +/-10.00W/m2 at heat flux less than 50W/m2
• Two-standard-deviation of +/-35.00% of expected value otherwise
Accelerometer (3-axis)
• Calibrated range is +/- 2.00g
• The minimum resolution is 0.01g
• Two-standard-deviation accuracy of +/-0.05g, up to 1.00g on longitudinal axis
• Two-standard-deviation accuracy of +/-12.00% of expected value otherwise on the longitudinal axis
• Two-standard-deviation accuracy of +/-0.06g up to 1.00g on the transverse axis
• Two-standard-deviation accuracy of +/-12.00% of expected value otherwise on transverse axis.
• Two-standard-deviation accuracy of +/-0.06g up to 1.00g on the forward axis
• Two-standard-deviation accuracy of +/-12.00% of expected value otherwise on forward axis.
Sensor Accuracy
Water resistance: 1 meter for 30 minutes when properly mated to the wing
assembly.
Operating temperature/humidity: 5°C to +40°C (50°F to 104°F)/100% RH
non-condensing
Humidity Condensing: 5 to 95% Relative Humidity non-condensing
Design and specifications are subject to change without notice.
features of the sensewear® armband
Transmit Power Class 8 - Less than 10mW output power
Duty Cycle Class 4 - permitted to operate at 100% duty cycle Receiver
Class 3 - Standard reliable SRD communication media
Classification of the device, as per 93/42 directives: IIa (rule 10)
Certification procedure : 93/42/EEC, Annex VI, VII.
Identification code of Notified Body involved: XXX
Identification code of Notified Body involved: XXX.
The Waste Electrical and Electronic Equipment Regulations
indicates separate collection for electrical and electronic
equipment.
TYPE B APPLIED PART
Tested to applicable safety standards.
Caution
features of the sensewear® armband
14
15
FCC 47CFR 15C TCB - 47 CFR Part 15 Subpart C Intentional Radiator
Certification Test
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit separate from
the receiver.
• Consult the dealer or an experienced radio/TV technician for help.
• CAUTION: Changes or modifications to this equipment not expressly
approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
FCC 47CFR 15B CLA - 47 CFR Part 15 Subpart B Unintentional Radiators Class
A Verification
FCC statement
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired
operation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
16
ETSI EN 300 440-1 V1.3.1 (2001-07) Electromagnetic compatibility and Radio
spectrum Matters (ERM);Short range devices; Radio equipment to be used in
the 1 GHz to 40 GHz frequency range
ETSI EN 301 489-3 - (Draft) Electromagnetic Compat. and Radio Spectrum
Matters (ERM); Harmonized EN for ElectroMag. Compatibility (EMC) of Radio
Comms. Equip. & Srvs.; Pt. 3: Specific Conditions for Short-Range Devices
(SRD) Operating on Freqs Between 9 KHz and 40 GHz V1.3.1
ETSI EN 301 489-1 - Electromagnetic Compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) Standard for Radio Equipment and Services; Part 1: Common Technical Requirements V1.3.1
CAN/CSA-C22.2 No.606.1-M90
CENELEC EN 60601-1-1 - Medical Electrical Equipment - Part 1: General
Requirements for Safety - Collateral Standard: Safety Requirements for Medical
Electrical Systems.
CENELEC EN 60601-1-2 - 2001 - Medical Electrical Equipment Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests IEC 60601-1-2: 2001
UL 60601-1 - UL Standard for Safety Medical Electrical Equipment, Part 1:
General Requirements for Safety First Edition
features of the sensewear® armband
features of the sensewear® armband
17
18
3. Use the user id and password provided to you to login.
4. You can now add facilitators. These are your health professionals that will
be administering the WMS program to your patients.
5. Once the facilitators have been registered, they can log in to the system and
begin entering Member (patient) accounts and setting up MBA or Weight
Management Programs.
6. Once an account and program are created, there are 5 steps to
complete set up:
Step 1. Agree to end user license agreement. Click Next.
Step 2. Record your patient’s basic body parameters. Click Next.
Step 3. Enter your patient’s weight loss goals. (Weight Management
Program Only). Click Next.
Step 4. Enter their daily targets. This includes targets for total energy expenditure (TEE)/calories burned, step, physical activity duration and
sleep. Click Next.
Step 5. Click Go to start armband registration.
We detected that your computer does not have the required software for Keystone system.
Missing Required Software
1. Go to www.sensewear.com and click on the link For Health Practitioners or
For Patients.
2. If this is your first time entering the site, you will be directed to the “Missing
Required Software” page. You must install the two support softwares to use
the WMS system. Click Next once you have completed both installations.
The patented SenseWear® platform is a marriage of three basic components—
a wearable monitor, a personal feedback device and a website. Working in
concert, these three components deliver the data and insight that enable true
behavior modification, guidance, and adherence.
The SenseWear® armband collects the data. The SenseWear® display shows
up-to-the-minute patient feedback. The SenseWear® WMS website allows armband data uploads and manual input of nutrition intake and health indicators
such as weight and blood glucose.
registration & account creation
your sensewear® armband
19
3. If using the SenseWear® wireless communicator, attach the wireless communicator to the USB cable. Windows will detect the new hardware and
display the Found New Hardware Wizard.
4. After completing the New Hardware Wizard, click Finish.
5. Click Register to configure the armband. The armband is now ready to
collect data.
Skip Step 3 if not using SenseWear® wireless communicator.
1. Plug the USB cable into a USB port on your computer.
2. Plug the opposite end of the USB cable into the armband. Windows will
detect the new hardware and display the Found New Hardware Wizard.
registration & account creation
1. Slide the SenseWear® armband onto your
left arm. The Status button should be
closer to your shoulder.
2. Adjust the strap so that it fits on your
arm comfortably, then secure the oval
pull-tab. Ensure that the sensors maintain continuous contact with your skin at
all times and that the armband does not
slide off your arm.
3. Sync the display device with the armband
by pressing the mode button and view
button simultaneously on the display
device and pressing the time stamp
button on the armband. A Welcome
message will appear on the display device
when you have successfully synced the
armband to the display.
4. The display device will go out-of-sync
when you are not wearing the armband,
to sync the display device again, press
only the mode button on the display
device and press the time stamp on the
armband.
PLACEHOLDER
PLACEHOLDER
20
The SenseWear® armband is designed to be worn on the back of the upper left
arm (the tricep muscle), touching the skin.
wearing the armband
21
NOTE: When the armband is on the arm, DO NOT connect it to the
USB cable.
NOTE: Fully charge the battery before first use. the battery will arrive
with a small, inital charge.
22
7. When your data has been uploaded, you will see the summary screen showing the comparison of your targets versus your actual data.
1. Go to www.sensewear.com and click on the link For Health Practitioners or
For Patients.
2. You will then be required to enter your user id and password. You will then
see the summary page of the user.
3. Select the member.
4. If not using the wireless communicator, connect
the armband to the USB cable.
5. Click the Upload Armband Data button.
6. Click Via USB Cable or Via Wireless Communicator.
Status Indicators
There is no on/off button on your SenseWear® armband. When the monitor
makes secure contact with your body, it automatically performs a “turning
on” sequence. This may take up to ten minutes for some people, depending
on your body state. At anytime you can press and hold the timestamp button,
you will hear a series of sounds as well as a which indicates the armband is
working properly.
NOTE: The armband unit will collect data for at least (7) eighteen hour
days on a single charge.
uploading data
wearing the armband
23
When I try to upload data from my armband, I get an error message.
1. If you are having difficulty uploading your armband data, it could be one
of several reasons. Please double check the following and try again. If the
problem still persists, please contact Technical Support.
2. If you are uploading wirelessly, make sure you are within 10 feet of your PC.
If you wander outside of this range, the upload may not work. Also, make
sure that your armband has had a chance to turn on. It can take up to 10
minutes for the armband to turn on after you have put it on your arm.
3. If you are uploading via the USB cable, make sure the cable is connected to
the armband and the port on the back of your PC.
4. Make sure your battery or available memory is not too low. To make sure
that the armband is powered on and the battery and memory are functioning, press the Status button while the armband is on your arm. If it produces the low sequence when you push it, the battery or memory is too low.
If it produces the very low sequence, the battery is drained or the memory is
full. When you plug the USB cable in while uploading, if the battery light is
red, it needs to be recharged before you can upload.
5. Make sure you have the USB driver installed on the computer you are using.
If you are using a computer that is different than the one you used during
registration and set-up when you first received the armband, you may need
to download the software that enables you to retrieve your data from the
armband to the computer. This is called the USB driver.
My armband is not automatically turning on when I slide it on my arm.
If your armband has not turned on within 10 minutes of putting it on, try
lightly moistening the back of your upper arm with water and slide the armband on again. It should turn on within a few minutes. If the problem persists,
please contact Technical Support.
troubleshooting
24
Solution 3: You may have reminders set on your armband. Check this by clicking on the Personal Assistance tab and clicking Reminders.
Solution 2: Press the Status button. If the memory lights are flashing red or
amber, the memory is low and you must upload the data and clear to continue
collecting data.
My armband is beeping while it is on my arm.
Solution 1: Press the Status button. If the battery lights are flashing red or
amber, the battery is low and will need to be replaced.
My armband is not responding. It seems to be off, and I cannot get it to come
back on.
Press the Status button. If the battery or memory lights are flashing red, either
the battery needs to be recharged or the memory is full. If after pressing the
Status button you still receive no feedback (no lights or sound), try recharging
the battery, it may have drained while you were not wearing the armband. If
after recharging the battery you still do not receive feedback, please contact
technical support and they will help solve the issue.
NOTE: When installing the support software on your machine,
make sure the armband or wireless communicator is NOT plugged
into the USB cable! This will cause the driver to fail to install. If this
happens, simply unplug the armband or Wireless Communicator from
the USB cable and plug it in again. The driver will then install properly.
troubleshooting
25
SenseWear® and BodyMedia® are registered trademarks of BodyMedia, Inc.
26
Patents and patents pending. The SenseWear® Weight Management Solution
armband, display and wireless communicator are covered by one or more
of the following patents: United States Patent Nos.: D439,981, 6,527,711,
6,595,929, 6,605,038, 7,020,508, 7,153,262; European Patent Nos.: 1,292,217,
1,292,218; and various worldwide patents pending. This notice is accurate as
of August 14, 2007. For latest information please see www.bodymedia.com.
When I press the armband button, the armband does not respond.
Disconnect the USB cable and hold the armband button for 15 seconds, release the button. Press the armband button again to see if it responds. Go into
the software and retrieve your data (upload) to re-sync your armband before
wearing again. Caution: Data loss may occur. .
Data that I thought was on my armband has been erased.
Your armband may not have turned on. If this is the case, the armband did not
collect data. Or your battery may need recharged.
legal information
troubleshooting

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2007:08:29 09:44:38-04:00
Modify Date                     : 2007:08:29 09:44:38-04:00
Page Count                      : 14
Creation Date                   : 2007:08:29 13:44:38Z
Mod Date                        : 2007:08:29 13:44:38Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : quang
Metadata Date                   : 2007:08:29 13:44:38Z
Creator                         : quang
Title                           : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PV8-MF

Navigation menu