Bosch Security Systems CDL1 Wireless Tri-tech Motion Detector User Manual F01U304624 02e ISC CDL1 W15GHK ING indd

Bosch Security Systems, Inc. Wireless Tri-tech Motion Detector F01U304624 02e ISC CDL1 W15GHK ING indd

Contents

User Manual

Download: Bosch Security Systems CDL1 Wireless Tri-tech Motion Detector User Manual F01U304624 02e ISC CDL1 W15GHK ING indd
Mirror Download [FCC.gov]Bosch Security Systems CDL1 Wireless Tri-tech Motion Detector User Manual F01U304624 02e ISC CDL1 W15GHK ING indd
Document ID2638325
Application IDxqsF5BFtURhlE9AYhtdHkA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize177.26kB (2215726 bits)
Date Submitted2015-06-05 00:00:00
Date Available2015-12-02 00:00:00
Creation Date2015-01-14 16:17:45
Producing SoftwareAcrobat Distiller 10.1.9 (Windows)
Document Lastmod2015-01-26 10:30:58
Document TitleF01U304624-02e_ISC-CDL1-W15GHK_ING.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: rum1fp

Changes or modifications not expressly approved
by Bosch Security Systems, Inc. can void the
user’s authority to operate the equipment.
UL/C-UL
Use only a Listed Class 2 limited-power source.
Standby power: The Listed control unit or a Listed
burglary power supply must provide 4 hours of
standby power.
Install the unit in accordance with National
Electrical Code NFPA 70 and Part 1 of the
Canadian Electrical code CSA C22.1.
Models ISC-CDL1-W15H & ISC-CDL1-W15K are
not UL or C-UL Listed.
FCC
This device complies with part 15 of the FCC
Rules. and Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following
two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference,
including interference that may cause undesired
operation of the device.
Test yearly
2,3m - 2,75 m
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils radio
exempts de licence. L’exploitation est autorisée
aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout
brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le
fonctionnement.
a type and maximum (or lesser) gain approved for
the transmitter by Industry Canada.
To reduce potential radio interference to other
users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary
for successful communication.
Optional Brackets: B328, B338, B335
A mounting bracket can reduce the detector’s
range and create dead zones. Not investigated
by UL. Not EN50131 compliant. La certificazione
IMQ decade nel caso di installazione del
rilevatore con gli snodi opzionali.
Conformément à la réglementation d’Industrie
Canada, le présent émetteur radio peut
fonctionner avec une antenne d’un type et
d’un gain maximal (ou inférieur) approuvé pour
l’émetteur par Industrie Canada.
Dans le but de réduire les risques de brouillage
radioélectrique à l’intention des autres
utilisateurs, il faut choisir le type d’antenne et
son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas
l’intensité nécessaire à l’établissement d’une
communication satisfaisante.
This product is intended for use in the
following countries within the European Union
and in other countries outside the European
Union:
ISC-CDL1-W15G (10.525 GHz): Austria,
Belgium, Denmark, Finland, Greece, Italy,
Luxembourg, Netherlands, Norway, Portugal,
Spain, Sweden.
ISC-CDL1-W15H (10.588 GHz): France, United
Kingdom
ISC-CDL1-W15K (9.35 GHz): Germany
Under Industry Canada regulations, this radio
transmitter may only operate using an antenna of
(7.5 ft - 9 ft)
1 | Unlock and open
2 | Surface mount
3 | Bracket mount (optional)
B338
B328
B335
4 | Terminal block removal
5 | Wire knock-out options
6 | Leveling
7 | Wiring
7b | Double EOL resistors
7a | Single EOL resistor
NC NC T
NC NC T
NC NC T
9 to 15 VDC
T T
NC NC
NC NC
NC NC
33 k
2.2 k
1.0 k
2.2 k
1.0 k
Bosch Security Systems, Inc.
33 k
2.2 k
1.0 k
1.0 k
2.2 k
33 k
2.2 k
1.0 k
2.2 k
1.0 k
33 k
33 k
2.2 k
1.0 k
2.2 k
1.0 k
2.2 k
1.0 k
2.2 k
1.0 k
33 k
2.2 k
1.0 k
2.2 k
1.0 k
F.01U.304.624 | 03 | 2015.01 | 2
7c | No EOL resistors
9 | Look-down feature
8 | DIP switches
10a | Walk test
ON
LED
NC NC T
2s
2s
2 min
HI
ON
PIR
33 k
2.2 k
1.0 k
2.2 k
1.0 k
EN Grade 2
LO
10b | Microwave adjustment
10c | Repeat walk test
2s
2s
2 min
Bosch Security Systems, Inc.
F.01U.304.624 | 03 | 2015.01 | 3
11 | Certifications
12 | Specifications
Region
Agency
Certification
US
FCC
FCC Part 15 Class B
UL
-W15G: Intrusion Detection Unit Type: S
Canada
Europe
France
CUL
-W15G: Intrusion Detection Unit Type: S
IC
1249A-CDL1
CENELEC
EN 50131-2-4
EN 50130-5
Environmental Class II,
Grade 2 / IP41 / IK04 (EN60529, EN 62262)
AFNOR/
CNPP
NF&A2P (ISC-CDL1-W15H seulement)
ISC-CDL1-WA15H Cert # xxxxxxxxxxxx
RTC 50131-2-4
NF-324-H58 2 boucliers – 110P2
AFNOR Certification: www.afnor.org
CNPP Cert.: www.cnpp.com
Autosurveillance à l’ouverture Immunité champ
magnétique
Germany
VdS
VdS Gxxxxxx
Class B
2110EN Enviromental Class 2
Belgium
ANPI/
INCERT
INCERT B-509-00xx/a: (ISC-CDL1-W15G)
Australia
ACMA
RCM
Voltage
(operating)
9 to 15 VDC, 9-15 V
9-15 Vcc
de 10 à 15 mA @ 12
Vcc en veille/en alarme,
source limitée en
puissance, ondulation
résiduelle 1 V.
Current
(maximum)
<35 mA
Alarm relay /
Tamper
<100 mA, 25 V
Operating
temperature
-30°C to +55°C
(-22°F to +130°F)
UL 0°C to +49°C
(+32°F to +120°F)
AFNOR/CNPP
-10°C to +55°C
Relative
humidity
Sweden
IMQ
SBSC
Certificato IMQ sistemi di sicurezza 3° livello di
prestazione secondo CEI79-2:1998 + Ab:2000
(modello W15G)
For svensk installationsanvisning se
www.boschsecurity.se
Copyright
This document is the intellectual property of Bosch Security Systems, Inc. and is
protected by copyright. All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be
registered trademarks and must be treated accordingly.
Commercial Series
TriTech detectors
ISC-CDL1-W15G,
ISC-CDL1-W15H, ISC-CDL1-W15K
en Installation Guide
95% non-condensing
UL and C-UL 93%
13 | Coverage pattern
7.5 m
Italy
, 2.5W
0 ft
7 ft
13 ft
20 ft
26 ft
33 ft
39 ft
50 ft
46 ft
25 ft
6m
20 ft
4m
13 ft
2m
7 ft
90°
0m
0 ft
2m
7 ft
4m
13 ft
6m
20 ft
7.5 m
25 ft
≤2.75 m
≥2.3 m
≤9 ft
≥7.5 ft
0m
0m
2m
4m
6m
8m
10 m
12 m
0 ft
14 m
15 m
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, NY 14450
USA
www.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
Bosch Security Systems, Inc. product manufacturing dates
Use the serial number located on the product label and refer to the Bosch Security
Systems, Inc. website at http://www.boschsecurity.com/datecodes/.
© 2015 Bosch Security Systems, Inc.
F.01U.304.624 | 03 | 2015.01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Author                          : rum1fp
Create Date                     : 2015:01:14 16:17:45-05:00
Modify Date                     : 2015:01:26 10:30:58-05:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 10.1.9 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2015:01:26 10:30:58-05:00
Format                          : application/pdf
Title                           : F01U304624-02e_ISC-CDL1-W15GHK_ING.indd
Creator                         : rum1fp
Document ID                     : uuid:3855640a-e5c5-4451-8860-c5e77b46c3bd
Instance ID                     : uuid:101ae98a-3100-4dce-bf3c-36172515b1ed
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T3X-CDL1

Navigation menu