Bosch Security Systems CDL1 Wireless Tri-tech Motion Detector User Manual F01U304624 02e ISC CDL1 W15GHK ING indd
Bosch Security Systems, Inc. Wireless Tri-tech Motion Detector F01U304624 02e ISC CDL1 W15GHK ING indd
Contents
- 1. User Manual
- 2. User Manual2
User Manual
Changes or modifications not expressly approved by Bosch Security Systems, Inc. can void the user’s authority to operate the equipment. UL/C-UL Use only a Listed Class 2 limited-power source. Standby power: The Listed control unit or a Listed burglary power supply must provide 4 hours of standby power. Install the unit in accordance with National Electrical Code NFPA 70 and Part 1 of the Canadian Electrical code CSA C22.1. Models ISC-CDL1-W15H & ISC-CDL1-W15K are not UL or C-UL Listed. FCC This device complies with part 15 of the FCC Rules. and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Test yearly 2,3m - 2,75 m Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Optional Brackets: B328, B338, B335 A mounting bracket can reduce the detector’s range and create dead zones. Not investigated by UL. Not EN50131 compliant. La certificazione IMQ decade nel caso di installazione del rilevatore con gli snodi opzionali. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. This product is intended for use in the following countries within the European Union and in other countries outside the European Union: ISC-CDL1-W15G (10.525 GHz): Austria, Belgium, Denmark, Finland, Greece, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden. ISC-CDL1-W15H (10.588 GHz): France, United Kingdom ISC-CDL1-W15K (9.35 GHz): Germany Under Industry Canada regulations, this radio transmitter may only operate using an antenna of (7.5 ft - 9 ft) 1 | Unlock and open 2 | Surface mount 3 | Bracket mount (optional) B338 B328 B335 4 | Terminal block removal 5 | Wire knock-out options 6 | Leveling 7 | Wiring 7b | Double EOL resistors 7a | Single EOL resistor NC NC T NC NC T NC NC T 9 to 15 VDC T T NC NC NC NC NC NC 33 k 2.2 k 1.0 k 2.2 k 1.0 k Bosch Security Systems, Inc. 33 k 2.2 k 1.0 k 1.0 k 2.2 k 33 k 2.2 k 1.0 k 2.2 k 1.0 k 33 k 33 k 2.2 k 1.0 k 2.2 k 1.0 k 2.2 k 1.0 k 2.2 k 1.0 k 33 k 2.2 k 1.0 k 2.2 k 1.0 k F.01U.304.624 | 03 | 2015.01 | 2 7c | No EOL resistors 9 | Look-down feature 8 | DIP switches 10a | Walk test ON LED NC NC T 2s 2s 2 min HI ON PIR 33 k 2.2 k 1.0 k 2.2 k 1.0 k EN Grade 2 LO 10b | Microwave adjustment 10c | Repeat walk test 2s 2s 2 min Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01 | 3 11 | Certifications 12 | Specifications Region Agency Certification US FCC FCC Part 15 Class B UL -W15G: Intrusion Detection Unit Type: S Canada Europe France CUL -W15G: Intrusion Detection Unit Type: S IC 1249A-CDL1 CENELEC EN 50131-2-4 EN 50130-5 Environmental Class II, Grade 2 / IP41 / IK04 (EN60529, EN 62262) AFNOR/ CNPP NF&A2P (ISC-CDL1-W15H seulement) ISC-CDL1-WA15H Cert # xxxxxxxxxxxx RTC 50131-2-4 NF-324-H58 2 boucliers – 110P2 AFNOR Certification: www.afnor.org CNPP Cert.: www.cnpp.com Autosurveillance à l’ouverture Immunité champ magnétique Germany VdS VdS Gxxxxxx Class B 2110EN Enviromental Class 2 Belgium ANPI/ INCERT INCERT B-509-00xx/a: (ISC-CDL1-W15G) Australia ACMA RCM Voltage (operating) 9 to 15 VDC, 9-15 V 9-15 Vcc de 10 à 15 mA @ 12 Vcc en veille/en alarme, source limitée en puissance, ondulation résiduelle 1 V. Current (maximum) <35 mA Alarm relay / Tamper <100 mA, 25 V Operating temperature -30°C to +55°C (-22°F to +130°F) UL 0°C to +49°C (+32°F to +120°F) AFNOR/CNPP -10°C to +55°C Relative humidity Sweden IMQ SBSC Certificato IMQ sistemi di sicurezza 3° livello di prestazione secondo CEI79-2:1998 + Ab:2000 (modello W15G) For svensk installationsanvisning se www.boschsecurity.se Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Commercial Series TriTech detectors ISC-CDL1-W15G, ISC-CDL1-W15H, ISC-CDL1-W15K en Installation Guide 95% non-condensing UL and C-UL 93% 13 | Coverage pattern 7.5 m Italy , 2.5W 0 ft 7 ft 13 ft 20 ft 26 ft 33 ft 39 ft 50 ft 46 ft 25 ft 6m 20 ft 4m 13 ft 2m 7 ft 90° 0m 0 ft 2m 7 ft 4m 13 ft 6m 20 ft 7.5 m 25 ft ≤2.75 m ≥2.3 m ≤9 ft ≥7.5 ft 0m 0m 2m 4m 6m 8m 10 m 12 m 0 ft 14 m 15 m Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany Bosch Security Systems, Inc. product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/. © 2015 Bosch Security Systems, Inc. F.01U.304.624 | 03 | 2015.01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : rum1fp Create Date : 2015:01:14 16:17:45-05:00 Modify Date : 2015:01:26 10:30:58-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 10.1.9 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:01:26 10:30:58-05:00 Format : application/pdf Title : F01U304624-02e_ISC-CDL1-W15GHK_ING.indd Creator : rum1fp Document ID : uuid:3855640a-e5c5-4451-8860-c5e77b46c3bd Instance ID : uuid:101ae98a-3100-4dce-bf3c-36172515b1ed Page Count : 4EXIF Metadata provided by EXIF.tools