Bosch Security Systems PR-ZB Motion Sensor User Manual

Bosch Security Systems, Inc. Motion Sensor F01U314039 02c RFPR ZB ING indd

a href="https://usermanual.wiki/Bosch-Security-Systems" itemprop="url"> Bosch Security Systems >

Users Manual

en Installation GuideRADION PIR ZBWireless Motion DetectorRFPR-ZB/RFPR-ZB-EU/RFPR-ZB-CHIRFPR-ZB-ES/RFPR-ZB-MS© 2016 Bosch Security Systems, Inc.     F.01U.314.039 | 02c | 2016.05Bosch Security Systems, Inc.130 Perinton ParkwayFairport, NY 14450USAwww.boschsecurity.comBosch Sicherheitssysteme GmbHRobert-Bosch-Ring 585630 GrasbrunnGermany02468100 7 13 20 26 33064202460201370713201240≥2.3 ≥7.5≤2.7 ≤9FeetFeetMetersMeters90°Top: Overhead viewBottom: Side viewFCCThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) this device must accept anyinterference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off  and on, the user is encouraged to try to correct the interference by one or more of the following measures:  – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for helpICUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peutfonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autresutilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.KeyDark green - PIR detection zonesYellow - PIR detection look-down zonesCoverage PatternSpecifi cationsDimensions 2.4 in x 4.3 in x 1.7 in (60 mm x 108 mm x 42 mm)Batteries Panasonic CR123A Lithium 3 VDCDuracell DL123A Lithium 3 VDCSanyo CR123A Lithium 3 VDCBattery life for one battery is up to 7 years. Adding asecond battery (optional) can increase battery life up to 10 years total.Battery capacity 1500 mAPet immunity Up to 45 lbs (20 kg).Operating temperature -20°F to +130°F (-30°C to +55°C)Non-condensing humidity 0% to 93%Mounting height 7.5 ft to 9 ft(2.3 m to 2.7 m) Use For indoor use onlyPRELIMINARY
Bosch Security Systems, Inc. | 2Callout ― Description1 ― Flat surface mounting holes2 ― Corner surface mounting holes3 ― Removable bubble level horizontal4 ― Bubble level holder (swivel mount only)5 ― Tamper plate6 ― Rotary lock7 ― Battery tray location8 ― Feature switches9 ― Look-down adjustment10 ― Tamper switch13456128971012221 | Overview 3 | Installation considerations4 | InstallationFigure 1.1: Detector base interior view (top), detector body interior view (bottom)The RADION PIR ZB is a wireless motion detector with ZigBee technology that has a dense zone pattern, and is easy to install.Point away from: – Glass exposed to the outdoors – Direct and indirect sunlight – Objects that change temperature rapidly such as heat sources or air conditioning outlets – Outside traffi  c – Objects animals might climb on (stairs, shelves, furniture)Install:  – On solid, vibration free surface – On a fl at or corner surface – Within recommended mounting height range measured from the fl oor – Where an intruder is most likely to cross through the coverage pattern Do not install: – Near rotating machines or other moving objects within the coverage pattern – Near objects that can block the fi eld-of-view – Where an intruder would only walk directly toward or away from the detector – Near direct hot or cold draftsPet immunity: – Up to 45 lbs (20 kg).Open the detector and mount the base to either a fl at surface, a corner, or a bracket. Opening the detector:1.  Turn the rotary lock at the bottom of the detector to the open position. The body slides down. Refer to Figure 4.1.2.  Pull apart to remove it from the base.Figure 4.1: Unlock and open detectorMounting the base:1.  Identify mounting location and surface for install. (Optional mounting brackets:  B335 and B338. Sold separately).2.  Identify mounting holes to use based on the mounting surface. Refer to Figure 1.1.  3.  Break away or drill through the appropriate mounting hole coverings in the base.1NOTICE!Do not break away or separate the tamper plate from the base.Figure 4.2 Surface mount: left; cornermount: rightLeveling the motion detector:1.  Position the base on the surface and mount in place using one screw and drywall anchor only. Do not over-tighten. 2.  Use the bubble level to ensure the base is level from side to side. Refer to Figure 4.3-A.3.  Remove the bubble level and place it into the bubble level holder to verify vertical  alignment. This is applicable for swivel mount brackets only. Refer to Figure 4.3-B. 4.  Make adjustments until the base is level, and mark the remaining surface mounting hole locations.5.  Remove the bubble level from the holder and place it back to its original position.6.  Secure the base with the remaining screws and drywall anchors. Use a total of 3 screws and drywall anchors for surface mount installations, and 2 screws and drywall anchors for corner mount installations.Figure 4.3: Level detector5 |  Confi gurationSetting the switches:1.  Switch 2 - LED illumination. The LED illuminates when the device detects  PIR activity. By default, the LED is disabled (switch down). If you do not want the LED indication after you fi nish the set up and walk tests, place the switch in the off  position (switch down).Confi gure the features and options located on the detector body before placing the detector body on the base. 5.1 |  Set the switches2NOTICE!Use of a bracket might reduce range and increase dead zone areas.NOTICE!At least one screw must beinserted into the tamper switchfor tamper protection.A. B.NOTICE!Supported mounting heights range from 7.5 ft to 9 ft (2.3 m to 2.7 m). 2 | Product Contents This poduct contains: – Wireless motion detector – Installation instructions – Hardware pack – Battery tray with one batteryYou will need a power drill and a fl at-head screwdriver to perform the installation.Use a smart phone and scan the following QR code for more information regarding installation and mounting considerations. PRELIMINARY
Download:
Mirror Download [FCC.gov]
Document ID2984796
Application ID4cMLRBvJA7Tz/ADu0NYRrw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize231.97kB (2899570 bits)
Date Submitted2016-05-06 00:00:00
Date Available2016-05-10 00:00:00
Creation Date2016-05-09 14:13:21
Producing SoftwareAcrobat Distiller 10.1.16 (Windows)
Document Lastmod2016-05-09 14:23:24
Document TitleF01U314039-02c_RFPR-ZB_ING.indd
Document CreatorPScript5.dll Version 5.2.2
Document Author: nie1fp
FCC ID Filing: T3X-PR-ZB

Navigation menu