Bosch Security Systems PR-ZB Motion Sensor User Manual F01U314039 02c RFPR ZB ING indd
Bosch Security Systems, Inc. Motion Sensor F01U314039 02c RFPR ZB ING indd
Users Manual
Coverage Pattern Specifications Batteries Feet Panasonic CR123A Lithium 3 VDC Duracell DL123A Lithium 3 VDC Sanyo CR123A Lithium 3 VDC Battery life for one battery is up to 7 years. Adding a second battery (optional) can increase battery life up to 10 years total. 1500 mA Pet immunity Up to 45 lbs (20 kg). Operating temperature -20°F to +130°F (-30°C to +55°C) Non-condensing humidity 0% to 93% Mounting height 7.5 ft to 9 ft (2.3 m to 2.7 m) Use For indoor use only 13 20 26 33 40 20 13 90° 13 20 ≤2.7 ≥2.3 ≤9 ≥7.5 RADION PIR ZB Wireless Motion Detector RFPR-ZB/RFPR-ZB-EU/RFPR-ZB-CHI RFPR-ZB-ES/RFPR-ZB-MS en Installation Guide FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: Feet Battery capacity 2.4 in x 4.3 in x 1.7 in (60 mm x 108 mm x 42 mm) Meters Dimensions 10 12 PRELIMINARY (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Meters Top: Overhead view Bottom: Side view Key Dark green - PIR detection zones Yellow - PIR detection look-down zones If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – – – Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help – IC Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante. Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © 2016 Bosch Security Systems, Inc. F.01U.314.039 | 02c | 2016.05 1 | Overview 2 | Product Contents The RADION PIR ZB is a wireless motion detector with ZigBee technology that has a dense zone pattern, and is easy to install. This poduct contains: – Wireless motion detector – Installation instructions – Hardware pack – Battery tray with one battery You will need a power drill and a flat-head screwdriver to perform the installation. 3 | Installation considerations 4 | Installation Open the detector and mount the base to either a flat surface, a corner, or a bracket. Opening the detector: 1. Turn the rotary lock at the bottom of the detector to the open position. The body slides down. Refer to Figure 4.1. 2. Pull apart to remove it from the base. Use a smart phone and scan the following QR code for more information regarding installation and mounting considerations. 10 Figure 1.1: Detector base interior view (top), detector body interior view (bottom) Callout ― Description 1 ― Flat surface mounting holes 2 ― Corner surface mounting holes 3 ― Removable bubble level horizontal 4 ― Bubble level holder (swivel mount only) 5 ― Tamper plate 6 ― Rotary lock Figure 4.1: Unlock and open detector Point away from: – Glass exposed to the outdoors – Direct and indirect sunlight – Objects that change temperature rapidly such as heat sources or air conditioning outlets – Outside traffic – Objects animals might climb on (stairs, shelves, furniture) Install: – On solid, vibration free surface – On a flat or corner surface – Within recommended mounting height range measured from the floor – Where an intruder is most likely to cross through the coverage pattern Do not install: – Near rotating machines or other moving objects within the coverage pattern – Near objects that can block the fieldof-view – Where an intruder would only walk directly toward or away from the detector – Near direct hot or cold drafts Pet immunity: – Up to 45 lbs (20 kg). 9 ― Look-down adjustment 10 ― Tamper switch NOTICE! At least one screw must be inserted into the tamper switch for tamper protection. Bosch Security Systems, Inc. A. B. PRELIMINARY 7 ― Battery tray location 8 ― Feature switches Mounting the base: 1. Identify mounting location and surface for install. (Optional mounting brackets: B335 and B338. Sold separately). 2. Identify mounting holes to use based on the mounting surface. Refer to Figure 1.1. 3. Break away or drill through the appropriate mounting hole coverings in the base. Leveling the motion detector: 1. Position the base on the surface and mount in place using one screw and drywall anchor only. Do not over-tighten. 2. Use the bubble level to ensure the base is level from side to side. Refer to Figure 4.3-A. 3. Remove the bubble level and place it into the bubble level holder to verify vertical alignment. This is applicable for swivel mount brackets only. Refer to Figure 4.3-B. 4. Make adjustments until the base is level, and mark the remaining surface mounting hole locations. 5. Remove the bubble level from the holder and place it back to its original position. 6. Secure the base with the remaining screws and drywall anchors. Use a total of 3 screws and drywall anchors for surface mount installations, and 2 screws and drywall anchors for corner mount installations. NOTICE! Use of a bracket might reduce range and increase dead zone areas. NOTICE! Do not break away or separate the tamper plate from the base. Figure 4.3: Level detector 5 | Configuration Configure the features and options located on the detector body before placing the detector body on the base. 5.1 | Set the switches Figure 4.2 Surface mount: left; corner mount: right NOTICE! Supported mounting heights range from 7.5 ft to 9 ft (2.3 m to 2.7 m). Setting the switches: 1. Switch 2 - LED illumination. The LED illuminates when the device detects PIR activity. By default, the LED is disabled (switch down). If you do not want the LED indication after you finish the set up and walk tests, place the switch in the off position (switch down). |2 NOTICE! The LED is active during the pairing process and walk test regardless of the setting of Dip switch 2. NOTICE! To preserve battery life, LED indications are visible only after 3 minutes have passed since the previous alarm restoral when the LED switch is set to on. LED illumination Switch setting ON ON OFF OFF ON 2 LED 6 | Battery installation The battery tray in this device has two compartments. The device requires only one battery to operate (included) and is already installed. You can add a second battery (not included) to extend battery life. If installing for the first time, remove the battery cardboard insert. To install the batteries: 1. Slide the battery tray into the detector body using two fingers with the finger cavity facing out. Be certain to slide the tray in until the top of the tray is flush with the top of the detector body and you feel it “click” into position. The LED stays lit for 2 seconds immediately after the battery “clicks” into place. Refer to battery insertion sequence in Figure 6.1. OFF 1. Table 5.1: Switch settings 5.2 | Look-down and Pet immunity switch NOTICE! Verify your home control system or security control panel is powered up and operational before beginning the pairing process. The unit powers up when batteries are installed. Slide the detector body onto the mounted base. Pairing the detector with the controller: 1. The red LED lights for two seconds, then the detector enters pairing mode. 2. The red LED flashes three times every five seconds until the controller discovers the detector. Complete the next step within three minutes to limit battery consumption. 3. As soon as the detector enters pairing mode, go to the controller and complete the pairing process according to the controller manufacturer’s instructions. NOTICE! If the controller does not discover the motion detector within three minutes, the motion detector exits pairing mode. The motion detector restarts pairing when motion is detected. PRELIMINARY 2. The motion detector has a rotary switch to enable or disable the look-down zone and pet immunity. Refer to Figure 5.2. • Enable the look-down zone by turning the dial to the right. Use this to detect motion in the area underneath the device. This also disables pet immunity and increases sensitivity by approximately 20% for use in higher security applications. • Disable the look-down lens to avoid false alarms from objects moving in the area underneath the device. This also enables pet immunity in applications with pets. 7 | Pairing process 8 | Complete the setup 3. Follow the instructions below to walk test the motion detector. 8.1 | Walk test the detector Performing the walk test: 1. Remove the detector body from the base then slide it back on. This starts a 15 second timer. The LED flashes red during this time. As soon as the LED flashing has completed, walk test mode starts. 2. Once started, the detector remains in walk test mode for as long as it senses motion. If no motion is detected for 90 seconds, the unit exits walk test mode. Be sure to begin walk testing within the 90 second window. 3. Start the walk test from the farthest point of the sensor’s coverage pattern. 4. During the walk test, observe the LED colors. • Red indicates PIR activity 8.2 | Complete the walk test 1. 2. 3. Once you complete the walk test, do not disturb the detector’s coverage pattern for 90 seconds. After 80 seconds, the detector flashes red to indicate the walk test time is about to expire. After flashing for 10 seconds, the detector exits walk test mode. 9 | Operation and maintenance In the normal operating mode, an alarm is transmitted only after three minutes have passed since the previous alarm restoral. This three minute lockout time reduces unnecessary RF transmissions in high traffic areas thereby extending battery life. It is recommended to clean the detector lens periodically using a moisten cloth dipped in water. Use a smart phone and scan the following QR code for additional information on walk test. 4. “Click” NOTICE! Product must be walk tested at least once each year. 5. 2 sec Figure 6.1: Battery insertion Figure 5.2: Look-down adjustment Bosch Security Systems, Inc. |3 9.1 | Battery replacement 9.2 | Detector reset Perform the following to replace the batteries: 1. Remove the detector from the base. Refer to Section 4 Installation to unlock the detector. 2. Hold the detector body with one hand. With the other hand, insert the tip of your finger into the cavity at the top of the battery tray. 3. Press down while sliding the tray completely out of the motion detector body. Refer to Figure 9.1. 4. Insert one or two batteries, observing proper polarity. Refer to the diagram on the battery tray for proper positioning. 5. Slide the battery tray into the detector body using two fingers with the finger cavity facing out. Be certain to slide the tray in until the top of the tray is flush with the top of the detector body until you feel it “click” into position. Unlock and open the detector then follow the steps below to reset the detector to factory settings: 1. Remove the battery tray. 2. Press and hold the tamper switch. 3. Reinsert the battery tray. 4. Release the tamper switch within four seconds after the battery tray is reinserted. 5. Slide the detector body onto the base. The detector LED flashes to indicate it is reset. 6. Repeat section 7 and 8 completely to pair the detector. 10 | Certifications Region Agency Certification US and Canada Control No.3170792 Conforms to ANSI/UL Std. 639 Conforms to ULC Std. S306-03 FCC FCC Part 15 Class B IC 1249A-PRZB ZigBee This ZigBee® Certified product works in global 2.4 GHz networks supporting ZigBee HA 1.2. ZigBee® Certified is a registered trademark of the ZigBee Alliance. ZigBee Cert No.xxxx ZigBee Cert No. ® NOTICE! The detector can also be reset remotely through the supporting controller. 10 | Troubleshooting Copyright This document is the intellectual property of Bosch Security Systems, Inc., and is protected by copyright. All rights reserved. PRELIMINARY Refer to the following sections for troubleshooting information. 10.1 | Low battery Figure 9.1: Removing the battery tray NOTICE! Battery life for one battery is good up to 7 years. Using a second battery (optional) can increase battery life up to 10 years total. NOTICE! Replace all old batteries with new ones. Do not mix between old batteries and new batteries. NOTICE! Bosch is committed to responsible environmental stewardship. Please dispose of batteries in accordance with local laws and regulations in your area. Contact your local waste disposal authorities or consult www.e-cyclingcentral.com to find an electronics recycling center near you. Bosch Security Systems, Inc. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. Bosch Security Systems, Inc. product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at http://www.boschsecurity.com/datecodes/. A trouble status reported on the controller might be the result of low batteries on the detector. To trouble-shoot the condition, begin by replacing the batteries. Refer to Section 4 Installation to unlock the detector and Section 9.1 Battery replacement to open/ replace batteries. Replacing the detector: 1. Slide the detector back onto the base. 2. This starts a 15 second timer. The LED cycles red, green, and yellow during this time. As soon as the LED cycling has completed, walk test mode starts. 3. Complete all steps in Section 7. 10.2 | Detector malfunction A trouble or error status might occur when the detector experiences a failure (for example low battery, detection failure). This is indicated by a single red LED flash every 10 seconds during normal operation, or by a rapid sequence of four red LED flashes when the detector attempts to enter walk test mode. Check your control panel status for more information. F.01U.314.039 | 02c | 2016.05 | 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : nie1fp Create Date : 2016:05:09 14:13:21-04:00 Modify Date : 2016:05:09 14:23:24-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : nie1fp Title : F01U314039-02c_RFPR-ZB_ING.indd Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2016:05:09 14:23:24-04:00 Producer : Acrobat Distiller 10.1.16 (Windows) Document ID : uuid:dd0c5830-4343-4eb5-9ae4-fdc9e1186d87 Instance ID : uuid:e7d2c08f-0346-40e4-aa2e-ea26299ed646 Page Count : 4EXIF Metadata provided by EXIF.tools