Bosch Termotecnologia 8708300122 Remote Control User Manual Remote control US
Bosch Termotecnologia S.A. Remote Control Remote control US
Users Manual
6 720 606 990 JS Bosch Remote Control for GWH-635-ES Contents Contents Declaration of Conformity FCC Remote Control Data Parts supplied Caution: the remote control is waterproof and can also be used in the shower . Nevertheless, you should ensure it is not immersed in water, for instance in the bathtub Using the Remote Control Maintenance Declaration of Conformity FCC 3 This device meets the requirements of FCC Directives and is compliant with the type-tested sample in the relative FCC test certificate. Safety Instructions B Read the following instructions very carefully to ensure perfect operation. B Follow safety instructions. Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Caution: The remote control can be used only in the following countries: United States of America and Canada. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 6 720 606 990 Remote Control Data Remote Control Data Remote control for temperature adjustment of Bosch water heaters GWH-635-ES. Support PCB’s connection cable Using the Remote Control 4.1 Description of the LCD Technical Data: Battery power supply Alkaline LR 6 2 x 1,5V Frequency 915 MHz Type of protection IP X6 Further Indications: Remote control Up to 6 remote controls can be programmed for one single appliance.. Fig. 2 Parts supplied Fig. 1 Multifunctional LCD Displays temperature, error codes and functions "Remote control in operation" indication (signal arriving at remote control) Device in operation (with burner on) Temperature measurement unit (possible in °C and °F) Remote control battery level indication (weak signal coming from the remote control) Priority function (temperature cannot be modified by other user interface when water is running) "Security lock" symbol Parts Remote control Remote control transceiver PCB 6 720 606 990 Using the Remote Control 4.2 Remote control transceiver PCB installation Warning: For safety reasons, disconnect the power supply to the heater. Remote control transceiver PCB installation B Open control box top cover (Fig. 3, pos. 1). B Remove the protective cover (Fig. 3, pos. 2) from one face of the support and fix it to the main PCB as shown in Fig. 3. Pre-installation preparation B Remove the plug from the supply socket. B Remove plastic decals on front panel. B Undo two Philips head screws located behind decals. B Lift front cover panel upward and remove. B Remove the lower cover from the control box. B Remove the 2 sets of cables from the control box PCB. B Undo connections from both ignition cables. B Remove holding bracket. B Remove control box. Control box is now out of the appliance casing. Fig. 3 B Remove the other protective cover and fix the remote control PCB as shown in Fig. 4. Assure that the face of the remote control PCB is against the control box. 6 720 606 990 Using the Remote Control • the control box in the appliance • all connections between the PCB and the appliance • lower cover in the control box • holding bracket • front cover panel. 4.3 Fig. 4 Support correct position B Using the supplied cable make the connection between the main PCB and the remote control PCB as shown in Fig. 5. Remote Control Activation Before the remote control will work it will have to be activated, using the procedure described below, and standing in front of the appliance. B Move the main switch on the appliance to the 0 position. B Press and hold key while at the same time turn the main switch to “ON” position (I). LCD shows one number and one rotating digit. The number represents the remote control which is to be registered, the first remote control will be registered Fig. 5 with number “0”, the second with number “1” and so on. B Close the control box cover. B Re-assemble: 6 720 606 990 Using the Remote Control The rotating digit shows that the electronics is expecting a registration. (tolerance from selected set point -5 + 3 °K). B Hold remote control in front of the control panel on the heater and press simultaneously remote control buttons and until the temperature indication is shown on the remote control LCD. B Switch ON/OFF switch to “OFF” position (0) and then back on (I). B Press buttons and in order to reach requested temperature. New remote control is programmed. 4.4 Fig. 6 4.5 Temperature adjustment "Program" Button on the Remote Control Hot Water Temperature Memorizing the water Adjustment by Remote temperature with the remote Control control "Program" button B Press the buttons or on the remote control (Fig. 6, pos. 2) until the required temperature appears on the remote control display (Fig. 6, pos. 1). B Press the buttons or on the remote control (Fig. 7, pos. 2), ) until the required temperature appears on the remote control display (Fig. 7, pos. 1). B When the required temperature is defined, turn on the hot water tap. B You will now be able to memorize this temperature by keeping the "Program" button on the remote B The required temperature will flash on the remote control display. B The flashing will stop when the required temperature is reached 6 720 606 990 Using the Remote Control control (Fig. 7, pos. 3) pressed for 3 seconds. Fig. 7 Memorising water temperature B Only one temperature can be memorized using the "Program" button on the remote control. B At this point the remote control will display the memorized temperature . When the hot water tap is turned on, the water heater will supply hot water at the temperature memorized on the remote control. If the temperature was memorized using remote control buttons (it is possible to combine up to six remote controls), it can only be modified whilst hot water is flowing if the same remote control is used again (see chapter 4.6 "Priority Function"). Using the "Program" button (operation with memorized temperature) To operate the equipment with a previously memorized temperature: B Press the "Program" button on the remote control. The remote control display or control panel will now show the previously memorized temperature. When the hot water tap is turned on, the water heater will supply hot water after a few seconds, at the memorized temperature. Apart from the temperature that can be memorized using the "Program" button on the control panel, a second temperature can be memorized on each remote control using the "Program" button, to meet the needs of each user. 6 720 606 990 Using the Remote Control 4.6 "Priority" function Temperature cannot be memorized or selected using the control panel buttons or even a second remote control when hot water is in use (e.g. during a shower) since the "Priority" function will automatically start up to stop another user modifying the temperature when hot water is in use. The equipment does not have a default temperature setting and therefore has no default "Priority" function.The "priority" will be attributed automatically by the first user who selects or memorises (on the remote control or on the control panel) a temperature for subsequent use (e.g. a shower). Then, when the hot water is used (e.g. for a shower), the control panel display and remote control/s display will show the symbol " ". The temperature may only be modified using the same buttons that memorized it (depending on whether the control panel or the remote control was used). The "Priority" function ends: • 5 minutes after the last use of the hot water (return to basic set up). • 2 minutes after selecting/ memorizing the temperature if no hot water is used immediately afterwards. Acquiring "priority” Any user can acquire "priority" for subsequent use of hot water, as follows: B Move main switch to position I. B Keep button pressed. or button B Select the required temperature. B Press the "Program" button for 3 seconds to memorize the temperature, if required. B Use the hot water within two minutes of acquiring "priority. 4.7 "Priority" cannot be acquired whilst the hot water tap is open. Error Messages This device has an error message system. Any anomalies will be 6 720 606 990 Maintenance indicated by an error code that will appear on the display (Fig. 2, pos. 1) and by a symbol indicating a "safety block" (Fig. 2, pos. 7). The device will be operative once again following the elimination of the fault and after pressing the reset button. To identify the type of anomaly, consult chapter 5 of the installation manual. Maintenance 5.1 Replacing batteries When batteries are flat, the symbol (Fig. 2, pos. 5) will appear on the display. B Remove the two screws on the back of the remote control. B Open the battery housing and remove the flat batteries, then replace with new batteries, ensuring they are inserted correctly. Warning: flat batteries must be replaced. Consequently, the manufacturer is not liable for any faults or damage caused by flat batteries. Do not create litter with flat batteries: ensure they are disposed of in the specific refuse containers. 5.2 Cleaning Use a damp cloth to clean parts of the remote control. No abrasive or solventbased detergents are needed. Certify that the rubber seal is correctly fitted between both plastic housing parts. B Close the battery housing using the two screws. 6 720 606 990 Maintenance 10 6 720 606 990 Maintenance 6 720 606 990 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Encryption : Standard V1.2 (40-bit) User Access : Print, Fill forms, Extract, Assemble, Print high-res Create Date : 2004:01:23 10:25:56 Producer : Acrobat Distiller 4.05 for Windows Author : ali5av Creator : PScript5.dll Version 5.2 Title : Remote control US.fm Modify Date : 2004:01:26 10:19:50+01:00 Page Count : 12 Has XFA : NoEXIF Metadata provided by EXIF.tools