Bosch ICP AMAX3 P1 Intrusion Panel, En/pl/tr Data Sheet (AMAX Panel 3000) AMAX 3000 En US 22656407691
User Manual: Bosch Data Sheet (AMAX panel 3000) ICP-AMAX3-P1 Intrusion panel, en/pl/tr
Open the PDF directly: View PDF
.
Page Count: 5
| Download | |
| Open PDF In Browser | View PDF |
Intrusion Alarm Systems | ICP-AMAX3-P1 Intrusion panel, en/pl/tr ICP-AMAX3-P1 Intrusion panel, en/pl/tr www.boschsecurity.com This hybrid panel is designed for residential and small to medium-sized businesses. It offers 32 zones and 8 areas and comes with an enclosure and a transformer. An on-board PSTN dialer transmits an alarm via the common telephone network to a phone and / or a communication center while at the same time a voice message is sent to the owner’s landline or mobile phone to inform him about an intruder’s presence. Commissioning the system is simple and involves minimum programming: the default settings already cover 90 % of the available functionality. Programming can either be done via the AMAX TEXT, LCD and LED keypads or via the programming software (A-Link Plus). The intrusion system can be used with both RADION wireless peripherals, operating at 433 Mhz and hardwired detectors from Bosch. u 32 zones / 8 areas / 128 user codes u On-board voice dialer u Macro functionality u USB direct connection System overview USB PSTN Telephone Network CMS Phone Functions Basic functions • Keypad code STAY / AWAY arming • One button STAY / AWAY arming A-Link Plus 2 | ICP-AMAX3-P1 Intrusion panel, en/pl/tr • On-board dialer with CID / SIA transmission format. Voice dialer transmits up to 4 recorded messages to landline/mobile phones in case of an alarm. Messages can be recorded with A-Link Plus and sent to the control panel with the remote programming software A-Link Plus • 16 weekly schedules with the option to add exceptions in the calendar • 3 programmable macros: several single functions from the keypad are combined to one customer macro function, can be executed by pressing one button • Remote maintenance operations (e.g. walk test, bypassing) • Installer can enable the service mode for comfortable programming without having alarms or outputs triggered • In multi-area set-up (direct and multiple arming), “area status” is displayed • Area name is displayed on the master or area text keypad • 4 on-board outputs (two monitored) • Up to three output event types can be configured for one physical output • Every zone except zone 1 can be used with four-wire fire detectors • Any zone can be used for chime mode (door bell) • Any zone can be used to detect a sensor tamper (DEOL) • Zones can be bypassed by name • Test mode for outputs and zones Optional functions • • • • Wireless devices (433 MHz) RADION from Bosch Zone inputs on extension modules (with DX2010) Relay outputs on extension modules (with DX3010) Connect outdoor sirens and IP cameras to an optional 8 relay module (DX3010) • Programming key • Arming, bypassing, isolating, operating outputs and inquiry with the RSC+ app on mobile devices (with the B426-M or the B450-M with B442 or B443 modules) Optional alarm transmission • IP communication with Bosch Conettix IP, SIA DC09 UDP and SIA DC 09 TCP protocols via B426-M and B450-M with B442 or B443 modules • GPRS communication with Bosch Conettix IP, SIA DC09 UDP and SIA DC 09 TCP protocols via B450-M with B442 or B443 modules Optional remote programming via A-Link Plus • IP communication (B426-M and B450-M with B442 or B443 modules) • GPRS communication (B450-M with B442 or B443 modules) Communication with Bosch Software Packages The AMAX system can communicate with the following software packages: Remote programming software A-Link Plus The AMAX system can be accessed and programmed via the remote programming software A-Link Plus. All control panel and status information are accessible and an operation of the AMAX panel from a remote location is possible. A-Link Plus can connect to the AMAX panel via USB, IP or modem. Compatibility information Basic PSTN communicator (integrated) Formats: Contact ID, SIA DC 03 Magnetic contacts All magnetic contacts, including recessed, terminal connection, miniature over-head door, and surface mount. Intrusion detectors All conventional intrusion detectors, including Blue Line, seismic, PIR, TriTech, photoelectric and TriTech PIR Microwave. Four-wire smoke detectors Conventional 12V smoke, heat and photoelectric smoke detectors. Optional Zone DX2010 zone input module Relays DX3010 output module IP communicator B426-M and B450-M with B442 or B443 modules GPRS/GSM communicator B450-M with B442 or B443 modules Assorted literature is available. Refer to the appropriate datasheet, brochure, and installation manuals for additional data. Availability varies according to sales region. Certifications and approvals Region Regulatory compliance/quality marks Germany VdS H116003 [AMAX 2100/3000, RFRCOPT, RFUN, RFDW-RM, RFDW-SM, RFPR-12, RFDL-11, RFKF-TB, RFKB-FB] Europe CE AMAX panel 2100, AMAX panel 3000 Parts included Quantity Component 1 AMAX panel 3000 including integrated PSTN communicator 1 Enclosure 1 Transformer 3 | ICP-AMAX3-P1 Intrusion panel, en/pl/tr Quantity Component Option bus 1 Tamper switch 13.8 (+3% / -5%) 1 Terminal block for power supply Option bus nominal output voltage under AC line input in VDC 1 Hardware accessory pack: EOL resistors Option bus output voltage range under AC line input in VDC 13.11 – 14.2 1 Operation Manual Option bus 1 maximum current in mA 500 Panel PCB maximum quiescent current in mA 100 Technical specifications Electrical Power supply type EN = A Transformer Transformer input in VAC 230 Transformer output in VAC 18 Transformer AC power in VA 20 Transformer fuse in mA 500 AC input Minimum operating voltage in VDC 195 Maximum operating voltage in VDC 253 Line voltage frequency in Hz 50 DC output maximum current for all components: dependency on battery Battery type 12 V / 7 Ah Bosch D 126 Low battery condition in VDC below 11.0 Minimum battery condition in VDC 10.8 Frequency bands of operation Power level for radio equipment GSM900 Class 4 (2W) - GPRS Class 33 GSM1800 Class 1 (1W) - GPRS Class 33 UMTS2100 Class 3 (0.25W) Mechanical DC output DC output maximum current for all components in mA Battery 1100 Dimension in cm (H x W x D) 26.0 x 28.0 x 8.35 Weight in g 1950 Panel features • Battery 7Ah standby 12h (recharge Batt 80% in 72h) = 550mA • Battery 7Ah standby 36h + 15min alarm current 500mA (recharge Batt 80% in 72h) = 150mA Number of zones 32 Number of on-board zones 8 Number of users 128 Number of events 256 history events, stamped with time, and date 256 EN history events, stamped with time, and date 256 dialer history events, stamped with time, and date Pin code variations 1000000 Aux 1 / 2 output Aux 1 / 2 output voltage +12V / GND Aux 1 / 2 nominal output voltage under AC line input in VDC 13.8 (+3% / -5%) Aux 1 / 2 output max. Vpp in mV 675 Aux 1 / 2 output voltage range under AC line input in VDC 12.82 – 13.9 Aux 1 / 2 output current in mA 500 Outputs PO -1 / PO -2 maximum supervised output current in mA 500 PO -3 maximum current in mA 100 Number of devices Number of keypads 8 Number of DX 2010 modules 3 Number of DX 3010 modules 2 Number of GPRS modules: B450M with B442 or B443 1 Number of IP modules: B426-M 2 (1 if 1 of the GPRS modules above is connected) 4 | ICP-AMAX3-P1 Intrusion panel, en/pl/tr IUI-AMAX3-LED16 LED keypad, 16-zone Number of RF receivers 1 Number of RADION RF repeaters 8 AMAX keypad 3000 L16 is a 16 zone LED keypad Certification: EN 50131-3 Grade 2 Number of RF sensors 32 Order number IUI-AMAX3-LED16 Number of DSRF RF keyfobs 24 IUI-AMAX4-TEXT Text keypad Number of RADION RF keyfobs 128 Order number IUI-AMAX4-TEXT Zones Zone 1 Single or dual end-of-line (EOL 2,2KΩ) NC, NO Zone 2 - 16 COM 7 Single or dual end-of-line (EOL 2,2KΩ) NC, NO Tamper AMAX keypad 4000 T, LCD text keypad, two lines with each 18 characters Enclosure tamper input (does not reduce point capacity) Option bus ICP-AMAX3-PCBP4 PCB board , en/fr/es/pt Mainboard for AMAX panel 3000 Language package 4: English, French, Spanish, Portuguese Order number ICP-AMAX3-PCBP4 DX2010 Input expander, 8-zone Zone expansion module with 8 DEOL zone inputs Order number DX2010 DX3010 Output expander, 8-relay Package includes only the DX3010 board Dimensions in mm 4 wire, Ø 0.6 - 1.2 Maximum cable length in m 200 (panel to last keypad) Maximum bus length in m 700 (maximum 14 devices, maximum 8 keypads) Order number DX3010 AE20EN Enclosure for module w/tamper skirt, EN AE20EN plastic enclosure for DX2010/DX3010 Order number AE20EN B426-M Ethernet communication module, mobile Minimum operating temperature in °C -10 Supports Ethernet communication for remote programming and mobile apps on AMAX and Solution Series control panels Maximum operating temperature in °C 55 B450-M Plug-in communicator interface, mobile Minimum relative humidity in % 10 Maximum relative humidity in % 95 Protection class IP 30, IK 06 Environmental Ordering information ICP-AMAX3-P1 Intrusion panel, en/pl/tr Language package 1: English, Polish, Turkish, Hungarian Not certified according to European standards Order number ICP-AMAX3-P1 Accessories IUI-AMAX-LCD8 LCD keypad, 8-zone AMAX keypad 2000 D8, 8 zones LCD icon keypad Order number IUI-AMAX-LCD8 IUI-AMAX3-LED8 LED keypad, 8-zone AMAX keypad 3000 L8 is a 8 zone LED keypad Certification: EN 50131-3 Grade 2 Order number IUI-AMAX3-LED8 Order number B426-M Supports cellular communication for remote programming and mobile apps on AMAX and Solution Series control panels Order number B450-M B442 Plug-in cellular module, GPRS Multi-function cellular communicator that provides IP communication over a (GPRS) cellular network Order number B442 B443 Plug-in Cellular, HSPA+ (3G+) Multi-function 3G/4G cellular communicator providing IP communication over a GPRS/EDGE/UMTS/HSPA+ cellular network Order number B443 ICP-EZPK Programming key Blue key for transferring configurations to and from Easy Series and AMAX panels Order number ICP-EZPK ICP-EZRU-0106 ROM UPDATE KEY - EZ V1 Green key for upgrading the panel firmware Order number ICP-EZRU-0106 5 | ICP-AMAX3-P1 Intrusion panel, en/pl/tr Represented by: Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, The Netherlands Phone: + 31 40 2577 284 emea.securitysystems@bosch.com emea.boschsecurity.com Germany: Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Security Systems 2017 | Data subject to change without notice 18243859211 | en, V17, 07. Dec 2017 North America: Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: +1 800 289 0096 Fax: +1 585 223 9180 onlinehelp@us.bosch.com www.boschsecurity.us Asia-Pacific: Robert Bosch (SEA) Pte Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: +65 6571 2699 apr.securitysystems@bosch.com www.boschsecurity.asia
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2017:12:07 16:20:49+01:00 Modify Date : 2017:12:07 16:20:49+01:00 Creator : AH Formatter V5.3 MR3 (5,3,2011,1116) for Windows (x64) Producer : Antenna House PDF Output Library 2.6.0 (Windows (x64)) Title : ICP-AMAX3-P1 Intrusion panel, en/pl/tr Trapped : False Page Count : 5EXIF Metadata provided by EXIF.tools