Bosch AN PAVIRO Factory System V1_1x Application Note (PAVIRO V1.1) De En US 33215889931
User Manual: Bosch Application note (PAVIRO Factory System v1.1) PVA-4CR12 Controller
Open the PDF directly: View PDF .
Page Count: 5
Download | |
Open PDF In Browser | View PDF |
1 | Application Note | Public Address | PAVIRO Factory Default System Bosch Security Systems | Public Address B hS it S t | P bli Add Application Note PAVIRO Factory Default System - v1.0 PAVIRO Factory Default System This application note describes the functions, installation and operation of this system. Component list: A basic system consists of: 1x PVA-4CR12 Controller 1x PVA-2P500 Amplifier 1x PVA-15CST Call Station 1x 24V/2A Power supply System features: 12 loudspeaker zones via 2 router clusters For each router cluster (zone 1-6 and zone 7-12) 500W loudspeaker load can be connected Selective announcement to each of the 12 loudspeaker zones via the call station A background music (program) source can be selectively activated by the call station into each loudspeaker zone (option) Maximum two audio signals can be activated simultaneously, but only one signal per router cluster The English EVAC-message "incident" can be triggered by a contact (option) A logical output is provided to mute external systems when an announcement or EVAC-message is active (option) 2 | Application Note | Public Address | PAVIRO Factory Default System Block Diagram: System Behavior: The system has to be operated with the call station PVA-15CST, only the evacuation is triggered by an external normal open contact. The operation of the call station is explained in the following figure: 3 | Application Note | Public Address | PAVIRO Factory Default System System installation: Zone 1 Zone 2 Program source Zone 3 Mute contact 24V/200mA Zone 4 EVAC start/stop Zone 5 termination Zone 6 24V DC INPUT Zone 7 Zone 8 Zone 9 Zone 10 termination Mains power Zone 11 Zone 12 o Create the cabling as shown in the wiring diagram. Take in account the requirements in the operation manuals PVA-4CR12 and PVA-2P500 in the chapter "Connections". NOTE: Unused loudspeaker outputs do not have to be wired. The CAN-BUS has to be terminated with the enclosed terminating resistors. NOTE: It is not allowed to terminate the audio Line 1-4. The connections drawn in dashed lines are optional and have to be wired only when the respective function is used. After finishing the cabling, the CAN address has to be set to "01" on the PVA-2P500 amplifier. NOTE: Before the address is set, make sure the PVA-2P500 is disconnected from the mains. Now the system can be connected to the power supply and activated. 4 | Application Note | Public Address | PAVIRO Factory Default System o The address of the call station PVA-15CST must be set to "01". This is done via the menu of the call station: o o o o o o o o o o To open the main menu, press the ▲ Button keep it held down and press the ▼button at the same time. Press the ▼ button until you reach the "CST Setup" menu item. After pressing the ↵ button, the "Input Password" dialog is showing. Press the button "2" (on the right side) four times and then the ↵ button. Press the ▼ Button, to navigate to the "CST Setup Menu" menu item and then the ↵ button. The display shows “CAN Address”. Press the ↵ button. Change the address with the ▲ button from “0” to “1” and press then the ↵ button. Press twice the ESC button to exit the menu. The date and clock settings are done via the PVA-15CST call station menu o o o o To open the main menu, press the ▲ Button keep it held down and press the ▼button at the same time. Press the ▼ button until you reach the "Date / Time" menu item. After pressing the ↵ -button, the current date and time can be entered by using the numeric keys 0-9. Press the ↵ button after the input and then the ESC button. o The date / time display can also be switched off, by the menu of the call station PVA15CST. o To open the main menu, press the ▲ Button keep it held down and press the ▼button at the same time. o Press the ▼ button until you reach the "CST Setup" menu item. o After pressing the ↵ button, the "Input Password" dialog is showing. o Press the button "2" (on the right side) four times and then the ↵ button. o Press the ▼ Button, to navigate to the "CST Setup Menu" menu item and then the ↵ button. o Press the ▼ button until you reach the "Show Date & Time" menu item. o Press the ↵ button. o Change the value with the ▲ button from “on” to “off” and press the ↵ button. o Press twice the ESC button to exit the menu. The system is ready for operation if all steps above are successful performed. 5 | Application Note | Public Address | PAVIRO Factory Default System Fault description and their elimination: The following table gives an overview of faults that may occur and how they can be eliminated. Explanation of the table CST TEXT = The error text that is displayed in the PVA-15CST call station DESCRIPTION = Description of this error type ACTION = Actions to eliminate the fault CST TEXT DESCRIPTION ACTION Contr. Data Fault Memory or Read/Write error. Controller defect, must be repaired by ASA. Watchdog Fault Watchdog error of the device. The system has rebooted. Press the "System Fault" button on the call station to reset the error. Contr. SW Fault The device firmware version is not compatible with the IRIS-Net version used. A firmware update of the Controller is necessary. Contr. HW Fault Error in the power supply or the A/D converters of the device. Controller defect, must be repaired by ASA. Temperature Fault Temperature overload of the device. The internal temperature of the controller is too high. Ensure sufficient cooling. DSP System Fault Error during the processing of audio data. Controller defect, must be repaired by ASA. Message Fault Collected Error of the message manager. Further details are provided in the message manager dialog (ERROR STATES). CAN Bus Fault Fault condition on the CAN bus (Amplifier and Router communication). Further details are provided in the Interface dialog (CAN INTERFACE). CST Bus Fault #%u Fault condition on the CST bus (call station communication). The parameter %u gives the slot number of the erroneous module. Check cable connections between the call station and call station port. Int.Router DSP Fault Error in the digital signal processing (DSP) of the Controller defect, must be repaired by ASA device. Int.Router HW Fault Hardware error. Controller defect, must be repaired by ASA Int.Router TMP Fault Temperature overload of the device. The internal temperature of the controller is too high. Ensure sufficient cooling. Int.Router PLT Fault Missing pilot tone at input 1 of cluster A. Check cable connections between amplifier output and AMP-IN 1 cluster A. Int.Router PLT Fault Missing pilot tone at input 1 of cluster B. Check cable connections between amplifier output and AMP-IN 1 cluster B. CST Fault #%u A connected PVA-15CST call station has transferred an error message. The parameter %u gives the address of the erroneous call station. Further details are provided in the PVACST dialog (Supervision). Amplifier Fault #%u A connected PVA-2P500 power amplifier has transferred an error message. The parameter %u gives the address of the erroneous amplifier. Further details are provided in the PVAAMP dialog (Supervision).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Author : rac2sab Create Date : 2017:05:05 10:15:18+02:00 Modify Date : 2017:06:21 15:00:05+02:00 XMP Toolkit : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30 Format : application/pdf Title : Microsoft Word - AN PAVIRO Factory Default System v1_1.docx Creator : rac2sab Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2017:06:21 15:00:05+02:00 Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:62ebfe6c-e25b-4059-8415-8766a0dc80c3 Instance ID : uuid:825ccc27-38f5-449b-935e-087c36454a3e Page Count : 5EXIF Metadata provided by EXIF.tools