Conettix D6600/D6100IPv6/D6100i

Computer Interface Manual

EN

Receiver/Gateway

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual |

Contents
1.0
1.1
1.2
2.0
2.1
2.2
3.0
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
3.1.7
3.1.8
3.1.9
3.1.10
3.1.11
3.1.12
3.1.13
3.1.14
3.1.15
3.1.16
3.1.17
3.1.18
3.1.19
3.1.20
3.1.21
3.1.22
3.1.23
3.1.24
3.1.25
3.1.26
3.1.27
3.1.28
3.1.29
3.1.30
3.1.31
3.1.32
3.1.33
3.2
3.2.1
3.2.2
3.2.3
3.2.4
3.2.5
3.2.6
2

System Connection ........................................................................................................... 4
Conettix D6686/D6682/D6680 Ethernet Network Adapter Connection ..................................... 4
Direct Connection – RS-232 ........................................................................................................ 5
Making the Right Connection ............................................................................................ 6
COM3 DB9 Connector ................................................................................................................. 6
Selecting Program Options in the D6600/D6100IPv6/D6100i .................................................... 7
Computer Communication Protocols ................................................................................ 8
D6500 Mode Messages ................................................................................................................ 8
Acron Super Fast (Message Type 9) ............................................................................................ 8
Ademco 4-1 Express (Message Type b) ....................................................................................... 9
Ademco 4-2 Express (Message Type c) ..................................................................................... 10
Ademco Contact-ID (Message Type a) ...................................................................................... 11
Ademco 10-Digit Contact-ID (Message Type a) ......................................................................... 12
Ademco High Speed, 4-8-1 (Message Type f) ............................................................................ 13
ADT SIA (Message Type S) ........................................................................................................ 14
Caller ID (Message Type e) ........................................................................................................ 15
CFSK (Message Type i) .............................................................................................................. 15
Common Formats (Message Type 1) ......................................................................................... 16
DNIS/ANI (Message Type N) ...................................................................................................... 17
DSC 4-3 (Message Type d) ........................................................................................................ 18
FBI Super Fast (Message Type F) .............................................................................................. 19
ITI (Message Type I) .................................................................................................................. 20
Link Test (Message Type 1) ....................................................................................................... 21
Robofon (Message Type j) ......................................................................................................... 22
Sescoa Super Speed (Message Type 7) .................................................................................... 23
Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ........................... 24
Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) ........................... 25
Seriee FSK (Message Type k) .................................................................................................... 26
Seriee DTMF (Message Type l) .................................................................................................. 27
SIA (Message Type S) ................................................................................................................ 28
Silent Knight FSK0 (Message Type 1)........................................................................................ 29
Silent Knight FSK1 (Message Type m)....................................................................................... 32
Silent Knight FSK2 (Message Type m)....................................................................................... 35
Silent Knight FSK80 D6500 mode (Message Type 1) ................................................................ 36
Telim (Message Type n) ............................................................................................................. 37
Text Message (Message Type 3) ................................................................................................ 38
Varitech FSK 4-1 (Message Type 1) ........................................................................................... 39
Varitech FSK 4-2 (Message Type 1) ........................................................................................... 40
VONK (Message Type V) ............................................................................................................ 41
X-SIA Text (Message Type S) ..................................................................................................... 42
SafeCom (Message Type p) ....................................................................................................... 43
SIA Mode Messages ................................................................................................................... 44
Acron Super Fast (Message Type 9) .......................................................................................... 44
Ademco Contact-ID (Message Type a) ...................................................................................... 45
Ademco 10-Digit (Message Type b) ........................................................................................... 46
Ademco 4-1 Express (Message Type b) ..................................................................................... 47
Ademco 4-2 Express (Message Type c) ..................................................................................... 48
Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f) ................................................. 49
Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual |
3.2.7 ADT SIA (Message Type S) ........................................................................................................ 50
3.2.8 Caller ID (Message Type ) ............................................................................................... 51
3.2.9 CFSK (Message Type i) .............................................................................................................. 52
3.2.10 Common Formats (Message Type ) ................................................................................. 53
3.2.11 DNIS/ANI (Message Type N) ...................................................................................................... 55
3.2.12 DSC 4-3 (Message Type d) ........................................................................................................ 56
3.2.13 FBI Super Fast (Message Type F) .............................................................................................. 58
3.2.14 ITI (Message Type I) .................................................................................................................. 60
3.2.15 Link Test (Message Type ) ............................................................................................... 60
3.2.16 RB2000 (Message Type R) Description ..................................................................................... 61
3.2.17 Robofon (Message Type j) ......................................................................................................... 62
3.2.18 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) ........................... 63
3.2.19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) ........................... 64
3.2.20 Seriee DTMF (Message Type l) .................................................................................................. 65
3.2.21 Seriee FSK (Message Type k) .................................................................................................... 66
3.2.22 Sescoa Super Speed (Message Type 7) .................................................................................... 67
3.2.23 Silent Knight FSK() (Message Type ) ............................................................................... 68
3.2.24 Silent Knight FSK1 (Message Type m)....................................................................................... 69
3.2.25 Silent Knight FSK2 (Message Type m)....................................................................................... 71
3.2.26 Silent Knight FSK80 (Message Type ) ............................................................................. 71
3.2.27 Telim (Message Type n) ............................................................................................................. 72
3.2.28 Varitech FSK 4-1 (Message Type ) .................................................................................. 73
3.2.29 Varitech FSK 4-2 (Message Type ) ................................................................................... 73
3.2.30 VONK (Message Type V) ............................................................................................................ 74
3.2.31 X-SIA text (Message Type ) .............................................................................................. 75
3.2.32 SafeCom (Message Type p) ....................................................................................................... 76
3.3
Input Command Processing ...................................................................................................... 77
Appendix A: Contact ID Event Code Classifications ................................................................... 78
Appendix B: Internal Messages .................................................................................................. 88
Appendix C: Modem4/ModemIIIa² Messages .............................................................................. 92
Appendix D: Network Messages ............................................................................................... 140
Appendix E: Pulse Output ........................................................................................................ 143
Appendix F: Format ID (by Message Type) – D6600 Only ......................................................... 152
Appendix G: ADT SIA Report Codes ......................................................................................... 156
Appendix H: RB2000 Messages (D6600 Only) .......................................................................... 161
Appendix I: SafeCom Messages (D6600 Only) ......................................................................... 169
Appendix J: Acknowledgement from Automation Software to D6600/D6100IPv6 Receiver ...... 180
Appendix K: Cyclic Redundancy Check (CRC) Calculation ....................................................... 181
Appendix L: Network Automation ............................................................................................. 184

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

3

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 1.0 System Connection

Trademarks
®

®

®

®

Microsoft , Windows , Windows 2000 , Windows XP , and Windows Vista are either registered
trademarks or trademarks of Microsoft Corporation in the United States and/or other countries.

1.0 System Connection
1.1

Conettix D6686/D6682/D6680 Ethernet Network Adapter Connection

Use the Conettix D6686/D6682/D6680 Ethernet Network Adapter to connect a manufacturer’s
automation software package to the D6600/D6100IPv6/D6100i when the software cannot receive
network data (Figure 1). Refer to the Special Conettix D6600 Applications in the Conettix
D6600/D6100IPv6/D6100i Network System Guide (P/N: 4998122712).
Figure 1:

D6600/D6100IPv6/D6100i System – Standard/Network Automation

1 - Automation PC
2 - Connection - PC COM Port to D6686/D6682/D6680 RS-232
3 - D6686/D6682/D6680
4 - Connection - D6686/D6682/D6680 to Hub/Switch
5 - Hub/Switch
6 - Connection – D6686/D6682/D6680 to Hub/Switch
7 - D6686/D6682/D6680
8 - Connection – D6686/D6682/D6680 RS-232 to D6100IPv6/D6100i COM3
9 - D6100IPv6/D6100i
10 - Connection - D6686/D6682/D6680 to Hub/Switch
11 - D6686/D6682/D6680
12 - Connection – D6686/D6682/D6680 RS-232 to D6600 COM3
13 – D6600
* For automation packages with network capabilities: The packet format received from the D6600/D6100IPv6/D6100i is
the same as for RS-232 reporting, except an internet protocol (IP) and user datagram protocol (UDP) header is
stamped on the packet as the data transmitted by either standard IP or UDP structure over the network. Automation
software can support the network communication easily by calling Socket functions, both provided in Windows and
Unix by using the built-in IP connections (or sockets) available in Windows and Unix.

4

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 1.0 System Connection
.

1.2

Direct Connection – RS-232

Figure 2 and Figure 3 show a D6600 System using any manufacturer’s automation software package
directly connected to a D6600/D6100IPv6/D6100i.
Figure 2:

D6600 System – Direct Connect

1 - Automation PC
2 - Connection - Automation PC COM port to D6600 COM3
3 - D6600
Figure 3:

D6100i System – Direct Connect

1 - Automation PC
2 - Connection - Automation PC COM port to D6100IPv6/D6100i COM3
3 - D6100IPv6/D6100i

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

5

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 2.0 Making the Right Connection

2.0 Making the Right Connection
2.1

COM3 DB9 Connector

The COM3 Port uses a standard DB9 female connector. The suggested connections to the computer
are shown in Figure 4 to Figure 6.
When connecting data terminal equipment (DTE) together (such as a COM1 port to PC serial port), a
null-modem cable must be used. One possible configuration for a null-modem cable is shown in
Figure 4.
Figure 4:

Null Modem Cable Configuration
DTE
DB-9 Pin

DTE
DB-9 Pin

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

When connecting data terminal equipment to data communication equipment (DCE) (such as the
D6600/D6100IPv6/D6100i COM port to a modem), a modem cable should be used (such as a straightthrough cable shown in Figure 5).
Figure 5:

Straight-through Modem Cable Configuration
DTE

DCE

1

8

2

3

3

2

4

20

5

7

6

6

7

4

8

5

9

22

Each pin of the modem cable is defined in Figure 6.

6

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 2.0 Making the Right Connection
.
Figure 6:

Modem Cable Pin Definitions

6

7

5

4

3

2

1

8

9

(Male DB9 on receiver)
12345-

2.2

Data carrier detect (DCD)
Receive (RX)
Transmit (TX)
Data terminal ready (DTR)
Signal-ground (SIG-GND)

6789-

Data set ready (DSR)
Ready to send (RTS)
Clear to send (CTS)
Ring indicator (RI)

Selecting Program Options in the D6600/D6100IPv6/D6100i

Use the D6600/D6100IPv6/D6100i keypad or the D6200 Programming Software to program the
receivers. Below are the recommended selections for programming when connecting the receivers to
an automation system. Additional selections can be found in the D6600/D6100IPv6/D6100i Program
Entry Guide (P/N: 4998122702).
Table 1:

Recommended Programming Selections

Receiver
Gateway
Number

Selects a number (01 to 99) that is included in every message to the computer in
both D6500 and SIA modes

Output
Format

Enable computer output messages in the selected format:
SIA

computer interface standard format, recommended (expanded
reporting capabilities)

D6500

21-character format output

Baud Rate

Use maximum speed supported by PC

Link Test

Tests if a supervision signal can be sent and received from the central station by
the receiver

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

7

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols

3.0 Computer Communication Protocols
3.1

D6500 Mode Messages

In D6500 Mode, the line number/group number sent to the computer is only one digit. Refer to
Table 2.
Table 2:

D6600 Line Number/Group Number Conversion Table

Line#
/Group #

Converted
to

Line#
/Group #

Converted
to

Line #
/Group #

Converted
to

Line #
/Group #

Converted
to

L01/G01

1

L09/G09

9

L17/G17

H

L25/G25

P

L02/G02

2

L10/G10

A

L18/G18

I

L26/G26

Q

L03/G03

3

L11/G11

B

L19/G19

J

L27/G27

R

L04/G04

4

L12/G12

C

L20/G20

K

L28/G28

S

L05/G05

5

L13/G13

D

L21/G21

L

L29/G29

T

L06/G06

6

L14/G14

E

L22/G22

M

L30/G30

U

L07/G07

7

L15/G15

F

L23/G23

N

L31/G31

V

L08/G08

8

L16/G16

G

L24/G24

O

L32/G32

W

In D6500 mode, any group that equals 33 is converted to an “X.” Any group greater than or equal
to 34 is converted to a “Y.” For lines that are grouped, Gxx appears instead of Lxx. For
networked accounts, Nxx appears instead of Lxx and the line number is identified.
3.1.1

Acron Super Fast (Message Type 9)

Acron Super
Fast Example

Table 3:

8

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

9

r

r

l

s

s

s

s

a

a

a

a

C

C

C

C

C

C

C

C

Message Type 9 (Acron Super Fast) Byte Description

#

Title

Description

1

Header Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

9

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group Number

Line number in the receiver gateway that sent the message.

6-9

Spaces

Six spaces.

10-13

Account Number

Account number, four digits.

14-21

Channels

Channels 1 to 8

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.2 Ademco 4-1 Express (Message Type b)
4-1 Express
Example

Table 4:

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

b

r

r

l

s

s

s

s

s

s

a

a

a

a

s

E

s

s

s

X

t

Message Type b (Ademco 4-1 Express) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

b

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

Space

One space.

17

E

Event Code, “A” as the default.

18-20

Spaces

Three spaces.

21

X

Zone number.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

9

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.3

Ademco 4-2 Express (Message Type c)

4-2 Express
Example

Table 5:

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

c

r

r

l

s

s

s

s

s

s

a

a

a

a

s

E

s

s

X

Message Type c (Ademco 4-2 Express) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

c

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

Space

One space.

17

E

Event Code, “A” as the default.

18-19

Spaces

Two spaces.

20-21

XY

Event code and zone number.

22

Trailer Character

Typically, this is HEX 14.

10

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Y

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.4 Ademco Contact-ID (Message Type a)
Contact ID
Example

Table 6:

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

a

r

r

l

s

a

a

a

a

1

8

Q

X

Y

Z

G

G

C

C

C

t

Message Type a (Ademco Contact ID) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

a

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Space

One space.

7-10

Account Number

Account number, four digits.

11-12

18

Ademco Contact-ID format number

13

Qualifier

Qualifier, 1=New event or opening, 3=New restore or closing,
6=Previous event.

14-16

XYZ

Class code and event code (see Appendix A: Contact ID Event Code
Classifications).

17-18

GG

Group number.

19-21

CCC

Zone codes or user ID.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

11

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.5

Ademco 10-Digit Contact-ID (Message Type a)

Contact
ID
Example

Table 7:

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10

11

12

13

14

h

a

r

r

l

s

a

a

a

a

a

a

a

a

15

16

17

18

19

20

21

22

23

24

25

26

27

28

a

a

5

8

Q

X

Y

Z

G

G

C

C

C

t

Message Type a (Ademco 10-Digit) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

ASCII a. Message Type a for Ademco Contact-ID format.

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Card Number

Line number in the receiver gateway that sent the message.

6

Space

One space.

7-16

Account Number

Account number, 10 digits.

17-18

58

Ademco Contact-ID format number for 10 digits account.

19

Qualifier

Qualifier, 1=New event or opening, 3=New restore or closing,
6=Previous event.

20-22

XYZ

Class code and event code (see Appendix A: Contact ID Event Code
Classifications).

23-24

GG

Group number.

25-27

CCC

Zone codes or user ID.

28

Trailer Character

Typically, this is HEX 14.

12

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.6 Ademco High Speed, 4-8-1 (Message Type f)
SCANCOM 4-8-1, 5-8-1, 6-8-1 - Available Upon Request

High
Speed
Example

Table 8:

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

h

f

r

r

l

a

a

a

a

a

a

s

C

C

C

C

s

C

C

C

C

s

C

t

Message Type f (Ademco High Speed, 4-8-1) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

f

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Account Number

Account number, up to six digits.
Account number less than six characters is right aligned with leading
ASCII spaces.

12

Space

One space.

13-16

CCCC

Channels 1 to 4.

17

Space

One space.

18-21

CCCC

Channels 5 to 8.

22

Space

One space.

23

C

Supervisory channel.

24

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

13

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.7

ADT SIA (Message Type S)

ADT SIA
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21

h

S

r

r

l

[

#

a

a

a

a

|

d

a

m

m

-

d

d

-

y

22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
y

Table 9:

t

I

h

h

:

m

m

:

s

s

E

M

M

Z

Z

Z

Z

/

*** t

ADT SIA (Message Type S) Byte Description

#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

S

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

space

One space.

7

#

#

8-11

Account Number

Up to sixteen digits in the account number.

12

|

Separator. Indicates more data positions after account number.

13-32

Date and Time

Date and time.

33

E

SIA block code.

34-35

Event Code

SIA event code (refer to Appendix G: ADT SIA Report Codes).

36-39

Zone

Zone number.

40

/

Separator.

41

***

Next block of data.

42

Trailer Character

Typically, this is HEX 14.

14

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.8 Caller ID (Message Type e)
Caller ID
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

e

r

r

1

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

t

Table 10: Caller ID (Message Type e) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

e

3-4

Receiver Number

Receiver gateway Number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-21

Caller ID

Up to sixteen digits, Caller ID with less than sixteen characters is
right aligned with leading ASCII spaces.

22

Trailer Character

Typically, this is HEX 14.

3.1.9

CFSK (Message Type i)

CFSK
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

i

r

r

l

s

s

s

s

a

a

a

a

a

a

T

T

E

E

s

s

t

Table 11: CFSK (Message Type i) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

i

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-9

Spaces

Four spaces.

10-15

Account Number

Six digit account number.

16-17

TT

Event Code.

18-19

EE

Zone/User ID.

20-21

Spaces

Two spaces.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

15

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.10 Common Formats (Message Type 1)
Type 1
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

l

r

r

l

a

a

a

a

a

a

a

a

a

a

E

E

y

y

y

y

t

Table 12: Common Formats (Message Type 1) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number in the receiver gateway that sent the message.

6-15

Account Number

Account number, up to ten digits. Account numbers less than ten
characters are right aligned with leading ASCII spaces.

16-17

Event Code

Event codes define the type of signal received and interpreted by the
D6500 receiver gateway.

18-21

Zone Number

Zone or ID number sent by the communicator. Zone numbers less
than four digits are right aligned with leading ASCII spaces.

22

Trailer Character

Typically, this is HEX 14.

The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats,
BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the
programmable option selected. The receiver gateway also sends internal and ModemIIIa² messages in
either D6500 mode or SIA mode, depending on the option selected. Refer to Appendix B: Internal
Messages and Appendix C: Modem4/ModemIIIa² for a list of the messages and their descriptions.

16

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.11 DNIS/ANI (Message Type N)
DNIS/ANI
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

H

N

r

r

l

s

D

d

d

d

d

d

d

d

d

d

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

d

d

&

a

a

a

a

a

a

a

a

a

a

a

t

Table 13: DNIS/ANI (Message Type N) Byte Description
#

Title

Description

1

Header Character
(H)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

N (Capital n).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Space

One space.

7

DNIS Identifier

DNIS identifier.

8-18

DNIS Number

DNIS number, up to 11 digits.

19

ANI Identifier (&)

ANI identifier.

20-30

ANI Number

ANI number, up to 11 digits.

31

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

17

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.12 DSC 4-3 (Message Type d)
DSC 4-3
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

d

r

r

l

s

s

s

s

s

s

a

a

a

a

s

E

s

X

Y

Table 14: DSC-4-3 (Message Type d) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

d

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

Space

One space.

17

E

Event Code, “A” as the default.

18

Space

One space.

19

X

Event code number.

20-21

YY

Zone number.

22

Trailer Character

Typically, this is HEX 14.

18

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Y

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.13 FBI Super Fast (Message Type F)
FBI Super
Fast Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

F

r

r

l

s

s

s

s

s

s

a

a

a

a

T

Z

Z

E

s

s

t

Table 15: FBI Super Fast (Message Type F) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

F (Capital f).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

T

Zone type.

17-18

ZZ

Zone number.

19

E

Event type.

20-21

Spaces

Two spaces.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

19

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.14 ITI (Message Type I)
ITI Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

I

r

r

l

s

s

s

a

T

a

a

a

a

G

I

Z

Z

E

Table 16: ITI (Message Type I) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

I (Capital i).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-8

Spaces

Three spaces.

9

Account Number

First digit account number.

10

Panel Type

Control panel Type.

11-14

Account Number

Next four digit account number.

15

G

Group number.

16

I

Open/close (O/C) User ID.

17-18

ZZ

Zone number.

19

E

Condition code.

20

W

Protection level was.

21

N

Protection level is.

22

Trailer Character

Typically, this is HEX 14.

20

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

W

N

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.15 Link Test (Message Type 1)
Link Test
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

1

r

r

0

s

s

s

s

s

s

s

s

s

s

s

@

s

s

s

s

t

The D6600/D6100IPv6/D6100i can automatically generate this message at the programmed intervals.
Table 17: Link Test (Message Type 1) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number as zero for link test.

6-15

Spaces

Eleven spaces.

16-17

Event Code

Event code is @ for link test.

18-21

Spaces

Four spaces.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

21

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.16 Robofon (Message Type j)
Robofon
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

j

r

r

l

s

s

s

s

a

a

a

a

a

a

E

E

s

s

Table 18: Robofon (Message Type j) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

j

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-9

Spaces

Four spaces.

10-15

Account Number

Six digit account number.

16-17

EE

Event code.

18-21

Spaces

Four spaces.

22

Trailer Character

Typically, this is HEX 14.

22

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

s

s

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.17 Sescoa Super Speed (Message Type 7)
Sescoa Super D6500 Byte Description
Speed
1
2 3 4 5 6 7
Example
h
7 r
r
l
s
s

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

s

s

s

s

a

a

a

a

s

I

A

A

C

s

t

Table 19: Sescoa Super Speed (Message Type 7) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

7

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account Number

Account number, four digits.

16

Space

One space.

17

I

Event code.

18-19

AA

Two digit zone code or the first two digits user code.

20

C

Space if zone report, or the last digit user code.

21

s

One space.

22

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

23

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.18 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g)
Scancom 416-1, 5-16-1,
6-16-1
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

h

g

r

r

l

a

a

a

a

a

a

s

C

C

C

C

s

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

C

C

C

C

s

C

C

C

C

s

C

C

C

C

s

C

t

Table 20: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte
Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

g

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Account Number

Account number up to six digits. Account numbers less than six
characters are right aligned with leading ASCII spaces.

12

Space

One space.

13-16

CCCC

Channels 1 to 4.

17

Space

One space.

18-21

CCCC

Channels 5 to 8.

22

Space

One space.

23-26

CCCC

Channels 9 to 12.

27

Space

One space.

28-31

CCCC

Channels 13 to 16.

32

Space

One space.

33

C

Supervisory channel.

34

Trailer Character

Typically, this is HEX 14.

24

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)
Scancom
4-24-1
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

h

r

r

l

a

a

a

a

a

a

s

C

C

C

C

s

C

C

C

C

s

23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44
C

C

C

C

s

C

C

C

C

s

C

C

C

C

s

C

C

C

C

s

C

Table 21: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte
Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

h

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Account Number

Account number up to six digits. Account numbers less than six
characters are right aligned with leading ASCII spaces.

12

Space

One space.

13-16

CCCC

Channels 1 to 4.

17

Space

One space.

18-21

CCCC

Channels 5 to 8.

22

Space

One space.

23-26

CCCC

Channels 9 to 12.

27

Space

One space.

28-31

CCCC

Channels 13 to 16.

32

Space

One space.

33-36

CCCC

Channels 17 to 20.

37

Space

One space.

38-41

CCCC

Channels 21 to 24.

42

Space

One space.

43

C

Supervisory channel.

44

Trailer Character

Typically, this is HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

25

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.20 Seriee FSK (Message Type k)
Seriee FSK
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

k

r

r

l

s

s

s

s

s

s

a

a

a

a

a

s

E

s

Z

Table 22: Seriee FSK (Message Type k) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

k

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-16

Account Number

Five digit account number.

17

Space

One space.

18

E

Event code.

19

Space

One space.

20 -21

ZZ

Zone number.

22

Trailer Character

Typically, HEX 14.

26

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Z

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.21 Seriee DTMF (Message Type l)
Seriee DTMF
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

l

r

r

l

L

L

*

a

a

a

a

a

a

*

...

t

Table 23: Seriee DTMF (Message Type l) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1 (lowercase L).

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-7

LL

Data length.

8

*

Data separator.

9-14

Account number

Four, five or six account numbers.

15

*

Data separator.

16-21

***

DTMF Seriee Data.

22

Trailer Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

27

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.22 SIA (Message Type S)
SIA Example D6500 Byte Description
Defined
1
2 3 4 5 6 7
Messages
h
S r
r
l
[
#

8

9

10 11 12 13 14 15 16 17 18 19 20 21

22

a

a

a

t

a

|

E

M

M

Z

Z

Z

Z

/

***]

Table 24: SIA (Message Type S) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

S

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

[

Open bracket.

7

#

#

8-11

Account
Number

Up to sixteen digits may be used in the account number.

12

|

Separator, indicates more data positions after account number.

13

E

SIA block code.

14-15

Event Code

SIA Event code.

16-19

Zone

Zone number.

20

/

Separator.

21

***]

Next block of data.

22

Trailer
Character

Typically, HEX 14.

Undefined Messages
When an SIA message contains unprintable characters (unprintable characters are out of ASCII range
0x32-0x7E) or without an account block:
SIA Example

28

D6500 Byte Description
1

2

3

4

5

6

7

h

S

r

r

L

[

data

. . .

N-1

N

]

t

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Table 25:

SIA (Message Type S) Byte Description

#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

S

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

[

Open bracket.

7-(N-2)

data

The received SIA message contains hex characters either with or
without account portion.

N

Trailer
Character

Typically, HEX 14.

3.1.23 Silent Knight FSK0 (Message Type 1)
Silent Knight D6500 Byte Description
FSK0 Example 1 2 3 4 5 6 7
h

1

r

r

l

s

s

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

s

s

s

s

a

a

a

a

s

E

s

s

s

Z

t

Table 26: Silent Knight FSK1 (Message Type m) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account
Number

Four digit account number.

16

Spaces

One space.

17

E

Event code.

18-20

Space

Three spaces.

21

Zone number

Zone number.

22

Trailer
Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

29

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Optional Silent Knight SK1 (Message Type m):
If Menu Item 2.5.16 in the D6600/D6100IPv6/D6100i Receiver is equal to 1, the following output
is used.
Silent Knight D6500 Byte Description
FSK1 Example 1 2 3 4 5 6 7
h

m

r

r

l

s

a

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

a

a

a

a

a

a

a

“

Z

Z

“

...

Table 27: Optional Silent Knight SK1 (Message Type m) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

m

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Spaces

One space.

7-14

Account
Number

Maximum eight-digit account code. If the account code is less than
eight digits, enter the actual number of digits without a leading space.

15

“

Separator.

16-17

ZZ

First zone number, up to eight reports, one report has two digits.

18

“

Separator.

19

***

More data.

21

Trailer
Character

Typically, HEX 14.

30

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Table 28: Silent Knight Automation Format

Report Code

Description

00:

To Automation

Note

2 5 16=0(EEZZ)

2 5 16=1(ZZ)

Alarm Panic

PAss

00

01 to 08:

Alarm 01 to 08

sA0x

01 to 08

09:

Holdup

Hass

09

10 to 19:

Alarm 10 to 19

sA1x

10 to 19

x=0 to 9

20 to 29:

Alarm Restore 10 to
19

sH1x

20 to 29

x=0 to 9

30:

Test Code

sXss

30

31:

Trouble Line 1

LT01

31

32:

Trouble Line 2

LT02

32

33:

Expand Trouble

ETss

33

34:

Forced Access

DFss

34

35:

Restore Line 1

LR01

35

36:

Restore Line 2

LR02

36

37:

Expand Restore

ERss

37

38:

Cancel Code

OCss

38

39:

Data Lost

RTss

39

40:

Closing

CL00

40

41 to 49:

Closing 01 to 09

CL0x

41 to 49

x=1 to 9

50 to 59:

Bypass 10 to 19

sB1x

50 to 59

x=0 to 9

60:

Trouble AC

ATss

60

61 to 68:

Trouble 01 to 08

sT0x

61 to 68

69:

Trouble BAT

YTss

69

70:

Restore AC

ARss

70

71 to 78:

Restore 01 to 08

sRss

71 to 78

79:

Restore BAT

YRss

79

80:

Access

DS00

80

81 to 89:

Access 01 to 09

DG0x

80 to 89

90:

Opening

OP00

90

91 to 99:

Opening 01 to 09

OP0x

91 to 99

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

x=1 to 8

x=1 to 8

x=1 to 9

31

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.24 Silent Knight FSK1 (Message Type m)
Silent Knight D6500 Byte Description
FSK1 Example
1 2 3 4 5 6 7
h

m

r

r

l

s

a

8

9

10 11 12 13 14 15 16 17 18 19

2128

29

a

a

a

…

t

a

a

a

a

“

E

E

Z

Z

Table 29: Silent Knight FSK1 (Message Type m) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

m

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Spaces

One space.

7-14

Account
Number

Maximum 8-digit account code. If the account code is less than 8
digits, enter the actual number of digits without a leading space.

15

“

Separator.

16-19

EEZZ

First event and zone number. If this is the only event, it will be ended
with the terminator. Up to 8 reports. One report has 4 digits: 1-digit
event code, 1-digit condition code, 2-digit zone code.

20

“

Separator.

21 - 28

***

Next data.

28

Trailer
Character

Typically, HEX 14.

32

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Optional Silent Knight SK1 (Message Type m):
If Menu Item 2.5.16 in the D6600/D6100IPv6/D6100i Receiver is equal to 1, the following output
is used.
Silent Knight D6500 Byte Description
FSK1 Example 1 2 3 4 5 6 7
h

m

r

r

l

s

a

8

9

10 11 12 13 14 15 16 17 18 19

21

a

a

a

t

a

a

a

a

“

Z

Z

“

...

Table 30: Optional Silent Knight SK1 (Message Type m) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

m

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Spaces

One space.

7-14

Account
Number

Maximum eight-digit account code. If the account code is less than
eight digits, enter the actual number of digits without a leading space.

15

“

Separator.

16-17

ZZ

First zone number, up to eight reports, one report has two digits.

18

“

Separator.

19

***

More data.

21

Trailer
Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

33

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Table 31: Silent Knight Automation Format

Report Code

Description

00:

To Automation

Note

2 5 16=0(EEZZ)

2 5 16=1(ZZ)

Alarm Panic

PAss

00

01 to 08:

Alarm 01 to 08

sA0x

01 to 08

09:

Holdup

Hass

09

10 to 19:

Alarm 10 to 19

sA1x

10 to 19

x=0 to 9

20 to 29:

Alarm Restore 10 to
19

sH1x

20 to 29

x=0 to 9

30:

Test Code

sXss

30

31:

Trouble Line 1

LT01

31

32:

Trouble Line 2

LT02

32

33:

Expand Trouble

ETss

33

34:

Forced Access

DFss

34

35:

Restore Line 1

LR01

35

36:

Restore Line 2

LR02

36

37:

Expand Restore

ERss

37

38:

Cancel Code

OCss

38

39:

Data Lost

RTss

39

40:

Closing

CL00

40

41 to 49:

Closing 01 to 09

CL0x

41 to 49

x=1 to 9

50 to 59:

Bypass 10 to 19

sB1x

50 to 59

x=0 to 9

60:

Trouble AC

ATss

60

61 to 68:

Trouble 01 to 08

sT0x

61 to 68

69:

Trouble BAT

YTss

69

70:

Restore AC

ARss

70

71 to 78:

Restore 01 to 08

sRss

71 to 78

79:

Restore BAT

YRss

79

80:

Access

DS00

80

81 to 89:

Access 01 to 09

DG0x

80 to 89

90:

Opening

OP00

90

91 to 99:

Opening 01 to 09

OP0x

91 to 99

34

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

x=1 to 8

x=1 to 8

x=1 to 9

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.25 Silent Knight FSK2 (Message Type m)
Silent Knight D6500 Byte Description
FSK2 Example 1 2 3 4 5 6 7
h

m

r

r

l

s

a

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

a

a

a

a

a

a

a

“

E

E

Z

Z

“

*** t

Table 32: Silent Knight FSK2 (Message Type m) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

m

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Spaces

One space.

7-14

Account
Number

Maximum eight-digit account code. If the account code is less than
eight digits, enter the actual number of digits without a leading space.

15

“

Separator.

16-19

EEZZ

First event and zone number. If this is the only event, it will be ended
with the terminator. Up to eight reports. One report has four digits:
one-digit event code, one-digit condition code, two-digit zone code.

20

“

Separator.

21

***

Next data.

22

Trailer
Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

35

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.26 Silent Knight FSK80 D6500 mode (Message Type 1)
Silent Knight
FSK80
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

1

r

r

l

s

s

s

s

s

s

A

A

A

A

s

A

s

s

Table 33: Silent Knight FSK80 (Message Type 1) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

12-15

Account
Number

16

Space

17

Filler character
A

18-19

Spaces

20-21

XY

Two-digit alarm zone code.

24

Trailer
Character

Typically, HEX 14.

36

Four-digit account number.

Always char “A”.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

X

Y

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.27 Telim (Message Type n)
Telim
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

h

n

R

R

L

s

A

A

A

A

A

A

s

E

T

T

Z

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

t

Z

Table 34: Telim (Message Type n) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

n

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

Space

One space.

7-12

Account
Number

Six digit account number.

13

Space

One space.

14

E

Event code.

15-32

TTZZZZZZZZZZ
ZZ

Input line number.

33

Trailer
Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

37

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.28 Text Message (Message Type 3)
Type 3
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

3

r

r

l

P

R

I

N

T

E

R

v

v

.

Table 35: Text Message (Message Type 3) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

3

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line Number

Line number fixed at 1.

6-21

Message Text

Sixteen characters in length.

22

Trailer
Character

Typically, HEX 14.

38

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

v

v

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.29 Varitech FSK 4-1 (Message Type 1)
Varitech FSK
4-1 Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

1

r

r

l

s

s

s

s

s

s

a

a

a

a

s

E

s

s

s

X

t

Table 36: Varitech FSK 4-1 (Message Type 1) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account
Number

Four digit account number.

16

Space

One space.

17

E

Event code.

18-20

Spaces

Three spaces.

21

X

Zone number.

22

Trailer
Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

39

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.30 Varitech FSK 4-2 (Message Type 1)
Varitech FSK
4-2 Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

1

r

r

l

s

s

s

s

s

s

a

a

a

a

s

E

s

s

Table 37: Varitech FSK 4-2 (Message Type 1) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

1

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-11

Spaces

Six spaces.

12-15

Account
Number

Four digit account number.

16

Space

One space.

17

E

Event code.

18-19

Spaces

Two spaces.

20-21

XY

Zone number.

22

Trailer
Character

Typically, HEX 14.

40

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

X

Y

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.31 VONK (Message Type V)
VONK

D6500 Byte Description

Example

1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

h

V

r

r

l

A

A

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

G

Table 38: VONK (Message Type V) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

V

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6-7

Account
Number

Two digit account number.

8-23

Zone status

Status of zones 1 to 16. If the zone is Closed, a “.”(period) is in this
position. If the zone is Open, 1 to G appears in this position.

24

Trailer
Character

Typically, HEX 14

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

41

t

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.1.32 X-SIA Text (Message Type S)
X-SIA Example D6500 Byte Description
1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18 19 20 21 22

h

S

r

r

l

[

#

a

a

a

a

|

E

M

M

Z

Z

Z

Z

*

23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42
T

T

T

T

T

T

T

T

T

T

T

T

‘

N

M

/

*

*

*

t

Table 39: X-SIA Text (Message Type S) Byte Description
#

Title

Description

1

Header
Character (h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

S

3-4

Receiver
Number

Receiver gateway number from 01 to 99.

5

Line/Group
Number

Line number in the receiver gateway that sent the message.

6

[

Open bracket.

7

#

#

8-11

Account
Number

Use up to sixteen digits in the account number.

12

|

Separator. Indicates more data positions after account number.

13

E

SIA block code.

14-15

MM

SIA event code.

16-19

ZZZZ

Zone number.

20

*

Text identifier.

21

‘

Quotation mark (single).

22-34

TT…T

13 character text string.

35

‘

Qutotation mark (single).

36-37

NM

Unit field characters.

38

/

Separator.

39-41

***

Next block of data.

42

Trailer
Character

Typically, HEX 14.

42

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

`

T

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.1.33 SafeCom (Message Type p)
SafeCom
Example

D6500 Byte Description
1

2

3

4

5

6

7

8

9

10

11

12

13

14

...

h

p

r

r

l

A

A

A

A

E

E

E

E

...data...

N-1

N
t

Table 40: SafeCom (Message Type p) Byte Description
#

Title

Description

1

Header Character
(h)

Optional. Check with the computer automation software for
compatibility.

2

Message Type

p

3-4

Receiver Number

Receiver gateway number from 01 to 99.

5

Line Card Number

Line number in the receiver gateway that sent the message.

6-9

Account Number

Four digits.

10-13

Event Code

Four digits.

14-(N1)

Data

Parameter data for event code.

N

Trailer Character

Typically, HEX 14.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

43

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols

3.2

SIA Mode Messages

Use the SIA mode for central station monitoring.
3.2.1 Acron Super Fast (Message Type 9)
Acron Super
Fast Example

SIA Mode Description
<9>[#aaaa|CCCCCCCC]

Table 41: Acron Super Fast (Message Type 9) Byte Description
Title

Description

L

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

9

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

Figure 7:

Message sent to printer

mm/ddshh:mmsLxxsACNsACCTsaaaa
+++sACCTsaaaasCCCCsCCCC
For lines that are grouped, Gxx appears instead of Lxx.

Table 42: Acron Super Fast (Message Type 9) Printer Output
Characters

Description

ACN

Acron Super Fast format.

Lxx

Line number.

Gxx

Grouped line numbers.

44

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.2 Ademco Contact-ID (Message Type a)
Contact-ID
Example

SIA Mode Description
[#aaaa|18QXYZGGCCC]

Table 43: Ademco Contact-ID (Message Type a) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

a

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

18

Ademco Contact-ID format number.

Q

Qualifier, 1 = New event or opening, 3 = New restore or closing, 6 =
Previous event.

XYZ

Class code and event code (refer to Appendix A: Contact ID Event Code
Classifications).

GG

Group number.

CCC

Zone codes or User ID.

Figure 8:

Message sent to printer

mm/ddshh:mmsLxxsCIDsACCTsaaaa
+++sACCTsaaaasNNNsEVENT=XYZsG=GGsC=CCC
For lines that are grouped, Gxx appears instead of Lxx.

Table 44: Ademco Contact-ID (Message Type a) Printer Output
Characters

Description

CID

Contact-ID format.

Gxx

Grouped Line numbers.

Lxx

Line number.

NNN

If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing
If Q = 6, print “OLD” for old messages and events.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

45

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.3

Ademco 10-Digit (Message Type b)

10-Digit
Example

SIA Mode Description
[#aaaaaaaaaa|58QXYZGGCCC]

Table 45: Ademco 10-Digit (Message Type b) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

a

Message Type a Ademco Contact-ID.

sequence#

The message sequence number. The valid sequence number range is 0001 to
9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for the
D6600/D6100/D6100IPv6.

line#

The line number of the line in the Receiver/Gateway that sent the message.
Valid digits are: 00- 99. The D6600 uses line#0 for Receiver/Gateway
messages.

account#

The communicator's account number.

58

Ademco Contact-ID format number for 10 digits account.

Q

Qualifier, 1=New event or opening, 3=New restore or closing, 6=Previous event

XYZ

Class code and event code (refer to Appendix A: Contact ID Event Code
Classifications)

GG

Group number

CCC

Zone codes or user ID

Figure 9:

Message sent to printer

mm/ddshh:mmsLxxsCIDsACCTsaaaaaaaaaa
+++sNNNsEVENT=XYZsG=GGsC=CCC
For lines that are grouped, Gxx appears instead of Lxx.

Table 46: Ademco Contact-ID (Message Type a) Printer Output
Characters

Description

CID

Contact-ID format.

Gxx

Grouped Line numbers.

Lxx

Line number.

NNN

If Q = 1, print E/O for new event or opening If Q = 3, print R/C for restore or closing
If Q = 6, print “OLD” for old messages and events.

46

Bosch Security Systems | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.4 Ademco 4-1 Express (Message Type b)
4-1 Express
Example

SIA Mode Description
[#aaaa|X]

Table 47: Ademco 4-1 Express (Message Type b) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

b

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

X

Zone number

Figure 10: Message sent to printer
mm/ddshh:mmsLxxsE41sACCTsaaaasEVENT=X
For lines that are grouped, Gxx appears instead of Lxx.

Table 48: Ademco 4-1 Express (Message Type b) Printer Output
Characters

Description

E41

Ademco 4-1 Express format.

Lxx:

Line number.

Gxx

Grouped line numbers.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

47

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.5

Ademco 4-2 Express (Message Type c)

4-2 Express
Example

SIA Mode Description
[#aaaa|XY]

Table 49: Ademco 4-2 Express (Message Type c) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

c

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

XY

Event code and Zone number.

Figure 11: Message sent to printer
mm/ddshh:mmsLxxsE42sACCTsaaaasEVENT=XY
For lines that are grouped, Gxx appears instead of Lxx.

Table 50: Ademco 4-2 Express (Message Type c) Printer Output
Characters

Description

E42

Ademco 4-2 Express format.

Lxx:

Line number.

Gxx

Grouped line numbers.

48

Bosch Security Systems | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.6 Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type f)
SCANCOM 5-8-1, 6-8-1 - available upon request
High Speed
Example

SIA Mode Description
[#aaaaaa|CCCCsCCCCsC]

Table 51: Ademco High Speed 4-8-1, SCANCOM 4-8-1 (Message Type F) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

f

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has up to six digits.

CCCC

Channels 1 to 4.

s

One space.

CCCC

Channels 5 to 8.

s

One space.

C

Supervisory channel.

Figure 12: Message sent to printer
mm/ddshh:mmsLxxsHGHsACCTsaaaaaa
+++sACCTsaaaaaasCCCCsCCCCsC
For lines that are grouped, Gxx appears instead of Lxx.

Table 52: Ademco High Speed, 4-8-1 (Message Type f) Printer Output
Characters

Description

HGH

Ademco High Speed format.

Lxx:

Line number.

Gxx

Grouped line numbers.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

49

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.7

ADT SIA (Message Type S)

ADT SIA
Example

SIA Mode Description
[#aaaa|data]

Table 53: ADT SIA (Message Type S) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

S (capital S)

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number up to sixteen digits.

E

Event Code (refer to Appendix G: ADT SIA Report Codes).

damm-dd-yytihh:mm:ss

Date and time.

Data

This field contains message data codes such as event type, area number,
point number, identification number.

50

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.8 Caller ID (Message Type )
SIA Example

SIA Mode Description
[#0000|&TTTTTTTTTTTTTTTT]

Table 54: Caller ID (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical Redundancy Check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6..

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

&

Origin ID Block.

T

Up to 16-digit Caller ID.

Figure 13: Message sent to Printer
30/04 17:00 L01 CLI 9563832510

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

51

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.9

CFSK (Message Type i)

CFSK Example

SIA Mode Description
[#aaaaaa|TTEE]

Table 55: CFSK (Message Type i) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

i.

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number, up to six digits.

TT

Event code.

EE

Zone/User ID.

52

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.10 Common Formats (Message Type )
Defined
Messages SIA
Example

SIA Mode Description
[#aaaaaaaaaaaaaaaa|data]

Table 56: Common Formats (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical Redundancy Check number.

Message Type

09 hex 

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number up to sixteen digits.

Data

This field contains message data codes such as event type, area number,
point number, identification number, and so on.

The receiver gateway sends the 3-1, 4-1, 4-2, single round, double round, extended pulse formats,
BFSK, Modem II or Modem IId messages in either D6500 Mode or SIA Mode, depending on the
program option selected. The receiver gateway also sends internal and ModemIIIa² messages in either
D6500 mode or SIA mode, depending on the programmable option selected. Refer to Appendix B:
Internal Messages and Appendix C: Modem4/ModemIIIa² for a list of the messages and their
descriptions.
Figure 14: Message sent to printer
MM/DDsHH:MMsLxxSIA ACCT aaaa
+++ TEXT 1
+++ TEXT 2

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

53

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Undefined Messages
When a common format message contains unprintable hexadecimal characters (unprintable
characters are out of ASCII range 0x32-0x7E) or without an account block:
SIA Example

SIA Mode Description
[data]

Table 57: Common Formats (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical Redundancy Check number.

Message Type

09 hex.

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The D6600/D6100/D6100IPv6 uses
Line 0 (zero) for receiver gateway messages.

Data

The receiver message contains hex characters either with or without
account portion.

Figure 15: Message sent to printer
MM/DDsHH:MMsLxx[SIA]
+++ TEXT 1
+++ TEXT 2

54

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.11 DNIS/ANI (Message Type N)
SIA Example

SIA Mode Description
[#0000|Dddddddddddd&aaaaaaaaaa]


Table 58: DNIS/ANI (Message Type N) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

N

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account#

Fixed at 0000.

D

DNIS identified.

DNIS number (d)

DNIS number, up to 11 digits.

ANI identifier (&)

ANI identifier.

ANI number (a)

ANI number, up to 11 digit.s

Figure 16: Message sent to printer
MM/DDsHH:MMsLxxsDNISsddddddddddd
+++sANIsaaaaaaaaaaa

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

55

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.12 DSC 4-3 (Message Type d)
DSC4-3
Example

SIA Mode Description
[#aaaa|XYY]

Table 59: DSC 4-3 (Message Type d) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

d

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

X

Event code number.

YY

Zone number.

Figure 17: Message sent to printer
mm/ddshh:mmsLxxsDSGsACCTsaaaasEVENT=XYY
+++sACCsaaaaseeeeeeeesiisnnn
For lines that are grouped, Gxx appears instead of Lxx.

56

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Table 60: DSC 4-3 (Message Type d) Printer Output
Characters

Description

DSG

DSC/Sur-Gard 4-3 format.

Lxx:

Line number.

Gxx

Grouped line numbers.

Table 61: Printer Output Codes
Character
s

Description

ii

ZN=Zone number - ID=User ID

nnn

Zone/User number.

eeeeeeee

Up to eight-character event type, right justified – ALARM, RESTORE, TROUBLE, OPEN,
OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL.

Table 62: Event Code Table
Code Number

Message

Event Characters

1

Alarm

A

2

A

3

A

4

Close

C

5

Open

O

6

Alarm

A

7

A

8

A

9

Restore

R

0

Trouble

T

B

CloseGrp

C

C

OpenGrp

O

D

Bypass

B

E

UnBypass

H

F

Cancel

O

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

57

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.13 FBI Super Fast (Message Type F)
FBI Super Fast
Example

SIA Mode Description
[#aaaa|TZZE]

Table 63: FBI Super Fast (Message Type F) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

F

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account#

The communicator's account number has four digits.

T

Zone type.

ZZ

Zone number.

E

Event type.

Figure 18: Message sent to printer
mm/ddshh:mmsLxxsFBIsACCTsaaaasETsnnn
+++sACCTsaaaastttttttttseeeeeeeesZNsnnn
For lines that are grouped, Gxx appears instead of Lxx.

58

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Table 64: FBI Super Fast (Message Type F) Printer Output
Characters

Description

FBI

FBI Super Fast format.

Lxx:

Line number.

Gxx

Grouped line numbers.

Table 65: Event Code Table
Code

Zone/Event Type

1

Fire

2

Panic

3

Burglary

4

Medical

5

Auxiliary

6

Bypass

7

Inactive

8

Eight

9

Nine

0

Zero

B

Opening

C

Closing

D

Abort

E

Restore

F

Trouble

Table 66: Printer Output Codes
Characters

Description

ZN

ZN=Zone number - ID=User ID

nnn

Zone/User number.

ttttttttt

Up to nine-character zone type, right justified FIRE, PANIC, BURGLARY, MEDICAL,
AUXILIARY.

eeeeeeee

Up to eight-character event type, left justified ALARM, RESTORE, TROUBLE, OPEN,
OPENGRP, CLOSE, CLOSEGRP, BYPASS, UN BYPASS, CANCEL.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

59

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.14 ITI (Message Type I)
ITI Example

SIA Mode Description
[#aaaaa|GIZZEWN]

Table 67: ITI (Message Type I) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

I (Captial I).

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account#

The communicator's account number has up to six digits.

G

Group number.

I

O/C User ID.

ZZ

Zone number.

E

Condition code.

W

Protection level was.

N

Protection level now.

3.2.15 Link Test (Message Type )
Link Test
Example

SIA Mode Description
 []

The D6600/D6100IPv6/D6100i can automatically generate this message at the preprogrammed
intervals.
Table 68: Link Test (Message Type ) Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
the D6600/D6100/D6100IPv6.

60

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.16 RB2000 (Message Type R) Description
RB2000
Example

SIA Mode Description
[]

Table 69: RB2000 (Message Type R) Byte Description
Title

Description

LF

Standard line feed character, hex 0A.

CRC

Cyclical redundancy check number.

R

ASCII R, Message Type R for RB2000 format.

sequence#

The message sequence number. The valid sequence number range: 0001
to 9999.

Receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for the
D6600.

line#

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal
messages.



VDS message sent as a hex string, the receiver extracts the alarm type.

CR

Hex 0D

Figure 19: Single message sent to Printer
MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx
+++ RB2000_EVENT_RAW_DATA
Figure 20: Multiple messages sent to printer
MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx
+++ RB2000_EVENT_RAW_DATA 1
+++ RB2000_EVENT_RAW_DATA 2
...
+++ RB2000_EVENT_RAW_DATA n

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

61

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Table 70: RB2000 (Message Type R) Printer Output
Characters

Description

MM/DDsHH:MM

Date and time.

RB2

RB2000 format.

Lxx

Line number.

ACCT
xxxxxxxxxxxx

Subscriber number, up to 12 characters(hex).

RB2000_EVENT_R
AW_DATA

The raw data of RB2000 event.

RB2000_EVENT_R
AW_DATA1

The raw data of RB2000 event 1.

RB2000_EVENT_R
AW_DATA 2

The raw data of RB2000 event 2.

RB2000_EVENT_R
AW_DATA n

The raw data of RB2000 event n.

3.2.17 Robofon (Message Type j)
Robofon
Example

SIA Mode Description
[#aaaaaa|EE]

Table 71: Robofon (Message Type j) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

j

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number has up to six digits.

EE

Event code.

62

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.18 Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g)
4-16-1
Example

SIA Mode Description

[#aaaaaa|CCCCsCCCCsCCCCsCCCCsC]

Table 72: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Byte
Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

g

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

Account#

The communicator's account number has up to six digits.

CCCC

Channels 1 to 4.

s

One space.

CCCC

Channels 5 to 8.

s

One space.

CCCC

Channels 9 to 12.

s

One space.

CCCC

Channels 13 to 16.

s

One space.

C

Supervisory channel.

Figure 21: Message sent to printer
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa
+++sACCTsaaaaaasCCCCsCCCCsCCCCsCCCCsC
For lines that are grouped, Gxx appears instead of Lxx.

Table 73: Scancom 4-16-1, 5-16-1, 6-16-1 - Available Upon Request (Message Type g) Printer
Output
Characters

Description

SCN

Scancom.

Lxx:

Line number.

Gxx

Grouped line numbers.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

63

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.19 Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h)
4-24-1
Example

SIA Mode Description
[#aaaaaa|CCCCsCCCCs
CCCCs CCCCsCCCCsCCCCsC]

Table 74: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Byte
Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

h

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account#

The communicator's account number, up to six digits.

CCCC

Channels 1 to 4.

s

One space.

CCCC

Channels 5 to 8.

s

One space.

CCCC

Channels 9 to 12.

s

One space.

CCCC

Channels 13 to 16.

s

One space.

CCCC

Channels 17 to 20.

s

One space.

CCCC

Channels 21 to 24.

s

One space.

C

Supervisory channel.

Figure 22: Message sent to printer
mm/ddshh:mmsLxxsSCNsACCTsaaaaaa
+++sACCTsaaaasCCCCsCCCCsCCCCsCCCC
++++++++++++++CCCCsCCCCsC
For lines that are grouped, Gxx appears instead of Lxx.

64

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
Table 75: Scancom 4-24-1, 5-24-1, 6-24-1 - Available Upon Request (Message Type h) Printer
Output
Characters

Description

SCN

Scancom.

Lxx:

Line number.

Gxx

Grouped line numbers.

3.2.20 Seriee DTMF (Message Type l)
Seriee DTMF
Example

SIA Mode Description
[#aaaa|*data]

Table 76: Seriee DTMF (Message Type l) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

l (lowercase L).

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number has four digits.

*

Data separator.

Data

DTMF Seriee Data.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

65

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.21 Seriee FSK (Message Type k)
Seriee FSK
Example

SIA Mode Description
[#aaaaa|EZZ]

Table 77: Seriee FSK (Message Type k) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

k

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

Account #

The communicator's account number has up to six digits.

E

Event code.

ZZ

Zone number.

66

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.22 Sescoa Super Speed (Message Type 7)
Sescoa Super
Speed
Example

SIA Mode Description
<7>[#aaaa| IAAC]

Table 78: Sescoa Super Speed (Message Type 7) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

7

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits are 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account#

The communicator's account number has four digits.

I

Event code.

AA

Two- digit zone code or the first two digits user code.

C

Space if zone report, or the last digit user code.

Figure 23: Message sent to printer
mm/ddshh:mmsLxxSESsACCTsaaaa +++sACCTsaaaasEEEseeeeeeeeeeeeee
For lines that are grouped, Gxx appears instead of Lxx.

Table 79: Sescoa Super Speed (Message Type 7) Printer Output
Characters

Description

SES

SESCOA Super Speed format.

Lxx

Line number.

Gxx

Grouped line numbers.

aaaa

Account code.

EEE

SESCOA Super Speed format event.

eeeeeeeeeeee
ee

Up to 14-characters of event description.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

67

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.23 Silent Knight FSK() (Message Type )
Silent Knight
FSK0 Example

SIA Mode Description
[#aaaa|data]

Table 80: Silent Knight FSK0 (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has four digits.

Data

Data.

68

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.24 Silent Knight FSK1 (Message Type m)
Silent Knight
FSK1 Example

SIA Mode Description
[#aaaa|
EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]

Table 81: Silent Knight FSK1 (Message Type m) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

m

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has four digits.

EEZZ”EEZZ”EEZZ”EEZ
Z”EEZZ”EEZZ”EEZZ”E
EZZ

Up to eight reports. One report has four digits: one-digit event code, onedigit condition code, and two-digit zone code. The quote (“) is the
separation character.

Optional Silent Knight FSK1 (Message Type m)
If Menu Item 2.5.16 in the D6600/D6100/D6100IPv6 Receiver is equal to 1, the following output
is used.
Silent Knight
FSK1 Example

SIA Mode Description
[#aaaa|ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”ZZ]

Table 82: Optional Silent Knight FSK1 (Message Type m) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

m

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has four digits.

ZZ”ZZ”ZZ”ZZ”ZZ”ZZ”Z
Z”ZZ

Up to eight reports. One report has two digits. The quote (“) is the
separate character.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

69

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Table 83: Silent Knight FSK1 Optional Outputs
Report Code

Description

To Automation

Note

2 5 16 = 0(EEZZ)

2 5 16 = 1(ZZ)

00

Alarm Panic

PAss

00

01 to 08

Alarm 01 to 08

sA0x

01 to 08

09

Holdup

Hass

09

10 to 19

Alarm 10 to 19

sA1x

10 to 19

x = 0 to 9

20 to 29

Alarm Restore 10 to
19

sH1x

20 to 29

x = 0 to 9

30

Test Code

sXss

30

31

Trouble Line 1

LT01

31

32

Trouble Line 2

LT02

32

33

Expand Trouble

ETss

33

34

Forced Access

DFss

34

35

Restore Line 1

LR01

35

36

Restore Line 2

LR02

36

37

Expand Restore

ERss

37

38

Cancel Code

OCss

38

39

Data Lost

RTss

39

40

Closing

CL00

40

41 to 49

Closing 01 to 09

CL0x

41 to 49

x = 1 to 9

50 to 59

Bypass 10 to 19

sB1x

50 to 59

x = 0 to 9

60

Trouble AC

ATss

60

61 to 68

Trouble 01 to 08

sT0x

61 to 68

69

Trouble BAT

YTss

69

70

Restore AC

ARss

70

71 to 78

Restore 01 to 08

sRss

71 to 78

79

Restore BAT

YRss

79

80

Access

DS00

80

81 to 89

Access 01 to 09

DG0x

80 to 89

90

Opening

OP00

90

91 to 99

Opening 01 to 09

OP0x

91 to 99

70

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

x = 1 to 8

x = 1 to 8

x = 1 to 9

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.25 Silent Knight FSK2 (Message Type m)
Silent Knight
FSK2 Example

SIA Mode Description
[#aaaaaa|
EEZZ”ECZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ”EEZZ]

Table 84: Silent Knight FSK2 (Message Type m) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

m

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has up to six digits.

EEZZ”EEZZ”EEZZ”EEZ
Z”EEZZ”EEZZ”EEZZ”E
EZZ

Up to eight reports. One report has four digits: one-digit event code, onedigit condition code, and two-digit zone code. The quote (“) is the
separation character.

3.2.26 Silent Knight FSK80 (Message Type )
Silent Knight
FSK80
Example

SIA Mode Description
[#AAAA|NBAXY]

Table 85: Silent Knight FSK80 (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages.

account #

The communicator's account number has four digits.

NBA

Alarm event

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

71

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols

Figure 24: Message sent to printer
MM/DDsHH:MMsLxxsSFKsACCTsAAAA
+++ACCTsAAAAsALARM_ZNs1
+++ACCTsAAAAsALARM_ZNs2
+++ACCTsAAAAsALARM_ZNs3
+++ACCTsAAAAsALARM_ZNs4
+++ACCTsAAAAsALARM_ZNs5
+++ACCTsAAAAsALARM_ZNs7
+++ACCTsAAAAsALARM_ZNs8
+++ACCTsAAAAsALARM_ZNs9
Table 86: Silent Knight FSK80 Printer/LCD output
Characters

Description

MM/DDsHH:M
M

Date and time.

SFK

SFSK80 format.

Lxx

Line number.

AAAA

The communicator's account number has four digits.

s

Space.

3.2.27 Telim (Message Type n)
Telim Example

SIA Mode Description
[#aaaaaa|EETTZZZZZZZZZZZZZZZZZZ]

Table 87: Telim (Message Type n) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

n

sequence#

The message sequence number. The valid sequence number range is
0001 to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the
message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for
internal messages.

account #

The communicator's account number has up to six digits.

EETTZZZZZZZZZZZZZZZZ
ZZ

The event type and input line number.

72

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.28 Varitech FSK 4-1 (Message Type )
Varitech FSK
4-1 Example

SIA Mode Description
[#aaaa|data]

Table 88: Varitech FSK 4-1 (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99 The receiver uses Line 0 (zero) for internal messages.

account#

The communicator's account number has four digits.

data

The event type and 1-digit zone number.

3.2.29 Varitech FSK 4-2 (Message Type )
Varitech FSK
4-2 Example

SIA Mode Description
[#aaaa|data]

Table 89: Varitech FSK 4-2 (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number has four digits.

data

The event type and two-digit zone number.

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

73

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
3.2.30 VONK (Message Type V)
VONK Example

SIA Mode Description
[#aa|123456789ABCDEFG]

Table 90: VONK (Message Type V) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type

V

sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number has two digits.

Data

Status of zones 1 to 16. If the zone is closed, a “.” (Period) appears in this
position. If the zone is open, any digit from 1 to G appears in this position.

74

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
.
3.2.31 X-SIA text (Message Type )
X-SIA Example

SIA Mode Description
[#aaaa|EMMZZZZ*'TTTTTTTTTTTTT'NM/***
]

Table 91: X-SIA text (Message Type ) Byte Description
Title

Description

LF

Standard line feed character.

CRC

Cyclical redundancy check number.

Message Type



sequence#

The message sequence number. The valid sequence number range is 0001
to 9999.

receiver#

The receiver gateway that sent the message. Valid digits: 01 to 99 for
D6600/D6100/D6100IPv6.

line#
(Line/Group #)

The line number of the line in the receiver gateway that sent the message.
Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal
messages.

account #

The communicator's account number has up to 16 digits.

E

SIA block code.

MM

SIA event code.

ZZZZ

Zone number.

*

Text identifier.

`

Single quote.

TT…TTT

13 character text string.

‘

Single quote.

NM

Unit field characters.

/

Separator.

***

Next data.

Figure 25: Message sent to printer
MM/DDsHH:MMsLxxsSIAsACCTsAAAA
+++sEMMZZZZ*'TTTTTTTTTTTTT'NM
+++sEMMZZZZ*'TTTTTTTTTTTTT'NM

Bosch Security Systems, Inc. | 2012.09 | 4998122703-05

75

Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication
Protocols
Table 92: X-SIA Printer/LCD output
Characters

Description

MM/DDsHH:MM

Date and time.

Lxx

Line number.

SIA

SIA format.

AAAA

Account code.

E

SIA block code.

MM

SIA event code.

ZZZZ

Zone number.

*

Text identifier.

‘

Single quote.

TTT…T

13 character text string.

‘

Single quote.

NM

Unit field characters.

3.2.32 SafeCom (Message Type p)
SafeCom
Example

SIA Mode Description

[#aaaa|EEEEdata] Table 93: SafeCom (Message Type p) Byte Description Title Description LF Standard line feed character. CRC Cyclical redundancy check number. Message p sequence# The message sequence number. The valid sequence number range is 0001 to 9999. receiver# The receiver gateway that sent the message. Valid digits: 01 to 99 for D6600. line# The line number of the line in the receiver gateway that sent the message. Valid digits: 00 to 99. The receiver uses Line 0 (zero) for internal messages. account # The communicator's account number has four digits. EEEE Event code, four digits. data Event code parameter data. 76 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | 3.0 Computer Communication Protocols . 3.3 Input Command Processing Input devices, such as automation systems, send the commands described in Table 94 to the receiver. If the receiver does not recognize a command, it generates a REJECT COMMAND message, prints at connected printers, and sends an ASCII text message to the automation port. The CPU programming in Menu Item 2.2.4 of the D6600/D6100/D6100IPv6 Receiver must be set to 1 to use input commands. Table 94: ASCII Text Message to Automation Port Set Time Set Date Stop Two Way Audio Reject Comma nd The automation system, or other device, sends the command shown below to set the time at the D6600/D6100/D6100IPv6 if the D6600/D6100/D6100IPv6 is programmed to synchronize the time and date with the automation system. D6650 Mode: !Thhmm SIA Mode: [CSThhmm] hh - hours (24 hour format) mm – minutes. The automation system, or other device, sends the command shown below to set the date at the D6600/D6100/D6100IPv6 if the D6600/D6100/D6100IPv6 is programmed to synchronize the time and date with the automation system. D6650 Mode: !Dmmddyy SIA Mode: [CSDmmddyy] mm - month, dd - day, yy – year The automation system, or other device, sends the command shown below to stop a two way audio session on the line specified. D6650 Mode: !Kn SIA Mode: [CLKnn] nn - line card number, 01-32. D6650 Mode: h3rrlsREJECTsCOMMANDsst SIA Mode: [REJECT COMMAND] Table 95: Input Command Output Messages D6500 Mode SIA Mode Printer Output Set Time h1rrssssssssssssXss2t [NJT] TIME SET Set Date h1rrssssssssssssXss51t [NJD] DATE SET Stop Two Way Audio h1rrssssssssssssXss52t [CLK] TWO WAY AUDIO STOP STOP Table 95 shows the D6500 and SIA automation output formats for these input commands. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 77 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Appendix A: Contact ID Event Code Classifications Figure 26: Contact ID format 1 2 3 4 5 1234 E 123 01 123 1 2 3 4 Customer (Subscriber Account Number) Event Qualifier - E = New Event, R = Restore Event Code - refer to Section A1 Event Codes Group or Partition Number, 00 to FF (2 Hex digits 0-9, B-F, always 00 for non-partitioned panels) 5 - Zone ID number* - reporting the alarm (001 to 999) or user number for open or close reports. * System status messages, such as AC Loss and Low Battery, are Zone ID 000. 78 - Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 96: Contact ID Event Code Classifications # Event Type Zone Medical: 100 Medical Emerg-Personal Emergency-# 101 Pendant Transmitter Emerg-Personal Emergency-# 102 Fail to report in Emerg-Fail to check in-# Fire Alarms: 110 Fire Fire-Fire Alarm-# 111 Smoke w/Verification Fire-Fire Alarm-# 112 Combustion Fire-Combustion-# 113 Waterflow Fire-Water Flow-# 114 Heat Fire-Heat Sensor-# 115 Pull Station Fire-Pull Station-# 116 Duct Fire-Duct Sensor-# 117 Flame Fire-Flame Sensor-# 118 Near Alarm Fire-Near Alarm-# Panic Alarms: 120 Panic Alarm Panic-Panic-# 121 Duress Panic-Duress-User # 122 Silent Panic-Silent Panic-# 123 Audible Panic-Audible Panic-# 124 Duress-Access Granted Panic-Duress Access Grant-# 125 Duress-Egress Granted Panic-Duress Egress Grant-# Burglar Alarms: 130 Burglary Burg-Burglary-# 131 Perimeter Burg-Perimeter-# 132 Interior Burg-Interior-# 133 24 HR Burg (Aux) Burg-24 Hour-# 134 Entry/Exit Burg-Entry/Exit-# 135 Day/Night Burg-Day/Night-# 136 Outdoor Burg-Outdoor-# 137 Tamper Burg-Tamper-# 138 Near Alarm Burg-Near Alarm-# 139 Intrusion Verifier Burg-Intrusion Verifier-# Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 79 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone General Alarms: 140 General Alarm Alarm-General Alarm-# 141 Polling Loop Open Alarm-Polling Loop Open 142 Polling Loop Short (AL) Alarm-Polling Loop Short 143 Expansion Mod Failure Alarm-Exp. Module Tamper-# 144 Sensor Tamper Alarm-Sensor Tamper-# 145 Expansion Module Tamper Alarm-Exp. Module Tamper-# 146 Silent Burg Alarm-Silent Burglary-# 24 Hour Non-Burglary: 150 24 Hour (Auxiliary Alarm-24 Hr. Non-Burg-# 151 Gas Detected Alarm-Gas Detected-# 152 Refrigeration Alarm-Refrigeration-# 153 Loss of Heat Alarm-Heating System-# 154 Water Leakage Alarm-Water Leakage-# 155 Foil Break Trouble-Foil Break-# 156 Day Trouble Trouble-Day Zone-# 157 Low Bottled Gas Level Alarm-Low Gas Level-# 158 High Temp Alarm-High Temperature-# 159 Low Temp Alarm-Low Temperature-# 161 Loss of Air Flow Alarm-Air Flow-# 162 Carbon Monoxide Detected Alarm-Carbon Monoxide-# 163 Tank Level Trouble-Tank Level-# Fire Supervisory: 200 Fire Supervisory Super.-Fire Supervisory-# 201 Low Water Pressure Super.-Low Water Pressure-# 202 Low CO2 Super.-Low CO2-# 203 Gate Valve Sensor Super.-Gate Valve-# 204 Low Water Level Super.-Low Water Level-# 205 Pump Activated Super.-Pump Activation-# 206 Pump Failure Super.-Pump Failure-# 80 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 96: # Contact ID Event Code Classifications (continued) Event Type Zone System Troubles: 300 System Trouble Trouble-System Trouble 301 AC Loss Trouble-AC Power 302 Low System Batt Trouble-Low Battery 303 RAM Checksum Bad Trouble-Bad RAM Checksum (Restore not applicable) 304 ROM Checksum Bad Trouble-Bad ROM Checksum (Restore not applicable) 305 System Reset Trouble-System Reset (Restore not applicable) 306 Panel Prog Change Trouble-Programming Changed (Restore not applicable) 307 Self-Test Failure Trouble-Self Test Failure 308 System Shutdown Trouble-System Shutdown 309 Battery Test Fail Trouble-Battery Test Failure 310 Ground Fault Trouble-Ground Fault-# 311 Battery Missing Trouble-Battery Missing 312 Power Supply Overcurrent Trouble-Pwr. Supp. Overcur.-# 313 Engineer Reset Status-Engineer Reset-User # (Restore not applicable) Sounder/Relay Troubles: 320 Sounder/Relay Trouble-Sounder/Relay-# 321 BELL 1 Trouble-Bell/Siren #1 322 BELL 2 Trouble-Bell/Siren #2 323 Alarm Relay Trouble-Alarm Relay 324 Trouble Relay Trouble-Trouble Relay 325 Reversing Relay Trouble-Reversing Relay 326 Notification Appliance CKT. #3 Trouble-Notification Appl. Ckt#3 327 Notification Appliance CKT. #4 Trouble-Notification Appl. Ckt#4 System Peripheral Troubles: 330 System Peripheral Trouble-Sys. Peripheral-# 331 Polling Loop Open Trouble-Polling Loop Open 332 Polling Loop Short Trouble-Polling Loop Short 333 Exp. Module Failure Trouble-Exp. Module Fail-# 334 Repeater Failure Trouble-Repeater Failure-# 335 Local Printer Paper Out Trouble-Printer Paper Out Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 81 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone 336 Local Printer Failure Trouble-Local Printer 337 Exp. Mod. DC Loss Trouble-Exp. Mod. DC Loss-# 338 Exp. Mod. Low bat Trouble-Exp. Mod. Low Batt-# 339 Exp. Mod. Reset Trouble-Exp. Mod. Reset-# 341 Exp. Mod. Tamper Trouble-Exp. Mod. Tamper-# 342 Exp. Module AC Loss Trouble-Exp. Module AC Loss-# 343 Exp. Module Self Test Fail Trouble-Exp. Self-Test Fail-# 344 RF Rcvr Jam Detect # Trouble-RF Rcvr Jam Detect-# Communication Troubles: 350 Communication Trouble-Communication Failure 351 Telco 1 Fault Trouble-Phone line #1 352 Telco 2 Fault Trouble-Phone line #2 353 LR Radio Xmitter Fault Trouble-Radio Transmitter 354 Failure To Communicate Trouble-Fail to Communicate 355 Loss of Radion Super. Trouble-Radio Supervision 356 Loss of Central Polling Trouble-Central Radion Polling 357 LRR XMTR. VSWR Trouble-Radio Xmitter. VSWR-# Protection Loop: 370 Protection Loop Trouble-Protection Loop-# 371 Protection Loop Open Trouble-Prot. Loop Open-# 372 Protection Loop Short Trouble-Prot. Loop Short-# 373 Fire Trouble Trouble-Fire Loop-# 374 Exit Error (By User) Alarm-Exit Error-# 375 Panic Zone Trouble Trouble-PA Trouble-# 376 Hold-Up Zone Trouble Trouble-Hold-Up Trouble-# 82 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone Sensor: 380 Sensor TRBL-Global Trouble-Sensor Trouble-# 381 Loss Of Supervision Trouble-RF Sensor Super.-# 382 Loss Of Supervisn Trouble-RPM Sensor Super.-# 383 Sensor Tamper Trouble-Sensor Tamper-# 384 RF Low Battery Trouble-RF Sensor Battery-# 385 Smoke Hi Sens. Trouble-Smoke Hi Sens.-# 386 Smoke lo sens. Trouble-Smoke Lo Sens.-# 387 Intrusion hi sens. Trouble-Intrusion Hi Sens.-# 388 Intrusion lo sens. Trouble-Intrusion Lo Sens.-# 389 Det. Self test fail Trouble-Sensor Test Fail-# 391 Sensor Watch Failure Trouble-Sensor Watch Fail-# 392 Drift Comp. Error Trouble-Drift Comp. Error-# 393 Maintenance Alert Trouble-Maintenance Alert-# Open/Close: 400 Open/Close Opening/Closing 401 Open/Close By User Opening-User #/Closing-User # 402 Group O/C Closing-Group User # 403 Automatic Open/Close Opening-Automatic/Closing-Automatic 404 Late to O/C Opening-Late/Closing-Late 405 Deferred O/C Event & Restore Not Applicable 406 Cancel (By User) Opening-Cancel 407 Remote Arm/Disarm Opening-Remote/Closing-Remote 408 Quick Arm Event not applicable for opening/closing-Quick Arm 409 Keyswitch Open/Close Opening-Keyswitch/Closing-Keyswitch 441 Armed Stay Opening-Armed Stay/Closing-Armed Stay 442 Keyswitch Armed Stay Opening-Keysw. Arm Stay/Opening-Keysw. Arm Stay 450 Exception O/C Opening-Exception/Closing-Exception 451 Early O/C Opening-Early/Closing-Early-Use r# 452 Late O/C Opening-Late/Closing-Late-User # 453 Failed to Open Trouble-Fail to open (Restore not applicable) Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 83 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone 454 Failed to Close Trouble-Fail to Close (Restore not applicable) 455 Auto-Arm Failed Trouble-Auto Arm Failed (Restore not applicable) 456 Partial Arm Closing-Partial arm-User # 457 Exit Error (User) Closing-Exit Error-User # 458 User on Premises Opening-User on Prem. –User # 459 Recent Close Trouble-Recent Close-User # (Restore not applicable) 461 Wrong Code Entry Access-Wrong Code entry (Restore not applicable) 462 Legal Code Entry Access-Legal Code entry-user # (Restore not applicable) 463 Re-arm after Alarm Status-Re Arm After Alarm-User # (restore not applicable) 464 Auto Arm Time Extended Status-Auto Arm Time Ext.-User # (Restore not applicable) 465 Panic Alarm Reset Status-PA Reset (Restore not applicable) Remote Access: 411 Callback Requested Remote-Callback Requested (Restore not applicable) 412 SuccessDownload/access Remote-Successful Access (Restore not applicable) 413 Unsuccessful Access Remote-Unsuccessful Access (Restore not applicable) 414 System Shutdown Remote-System Shutdown 415 Dialer Shutdown Remote-Dialer Shutdown 416 Successful Upload Remote-Successful Upload (Restore not applicable) Access Control: 421 Access Denied Access-Access Denied-User # (Restore not applicable) 422 Access Report by User Access-Access Gained-User # (Restore not applicable) 423 Forced Access Panic-Forced Access-# 424 Egress Denied Access-Egress Denied (Restore not applicable) 425 Egress Granted Access-Egress Granted (Restore not applicable) 426 Access Door Propped Open Access-Door Propped Open-# 427 Access Point DSM Trouble Access-ACS Point DSM Trbl.-# 428 Access Point RTE Trouble Access-ACS Point RTE Trbl.-# 429 Access Program Mode Entry Access-ACS Prog. Entry-User # (Restore not applicable) 84 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone 430 Access Program Mode Exit Access-ACS Prog. Exit-User # (Restore not applicable) 431 Access Threat Level Change Access-ACS Threat Level Chg. 432 Access Relay/Trigger Fail Access-ACS Relay/Trig. Fail-# 433 Access RTE Shunt Access-ACS RTE Shunt-# 434 Access DSM Shunt Access-ACS DSM Shunt-# System Disables: 501 Access Reader Disable Disable-Access Rdr. Disable-# Sounder/Relay Disables: 520 Sounder/Relay Disable Disable-Sounder/Relay-# 521 Bell 1 Disable Disable-Bell/Siren #1 522 Bell 2 Disable Disable-Bell/Siren #2 523 Alarm Relay Disable Disable-Alarm Relay 524 Trouble Relay Disable Disable-Trouble Relay 525 Reversing Relay Disable Disable-Reversing Relay 526 Notification Appliance Ckt #3 Disable-Notification Appl. Ckt #3 527 Notification Appliance Ckt #4 Disable-Notification Appl. Ckt #4 System Peripheral Disables: 531 Module Added Super.-Module Added (Restore not applicable) 532 Module Removed Super.-Module Removed (Restore not applicable) Communication Disables: 551 Dialer Disabled Disable-Dialer Disable 552 Radio Xmitter Disabled Disable-Radio Disable 553 Remote Upload/Download Disable-Rem. Up/Download Disable Bypasses: 570 Zone/Sensor Bypass Bypass-Zone Bypass-# 571 Fire Bypass Bypass-Fire Bypass-# Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 85 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone 572 24 Hour Zone Bypass Bypass-24 Hour Bypass-# 573 Burg. Bypass Bypass-Burg. Bypass-# 574 Group Bypass Bypass-Group Bypass-User # 575 Swinger Bypass Bypass-Swinger Bypass-# 576 Access Zone Shunt Access-ACS Zone Shunt-# 577 Access Point Bypass Access-ACS Point Bypass-# Test/Misc.: 601 Manual Test Test-Manually Triggered (Restore not applicable) 602 Periodic Test Test-Periodic (Restore not applicable) 603 Periodic RF Xmission Test-Periodic Radio (Restore not applicable) 604 Fire Test Test-Fire Walk Test-User # 605 Status Report To Follow Test-Fire Walk-User # 606 Listen-In To Follow Listen-Listen-In Active (Restore not applicable) 607 Walk-Test Mode Test-Walk Test Mode-User # 608 System Trouble Present Test-System Trouble Present (Restore not applicable) 609 Video XMTR Active Listen-Video Xmitter Active (Restore not applicable) 611 Point Tested OK Test-Point Tested OK-# (Restore not applicable) 612 Point Not Tested Test-Point Not Tested-# (Restore not applicable) 613 Intrusion Zone Walk Tested Test-Intrn Zone Walk Test-# (Restore not applicable) 614 Fire Zone Walk Tested Test-Fire Zone Walk Test-# (Restore not applicable) 615 Panic Zone Walk Tested Test-PA Zone Walk Test (Restore not applicable) 616 Service Request Trouble-Service Request Event Log: 621 Event Log Reset Trouble-Event Log Reset (Restore not applicable) 622 Event Log 50% Full Trouble-Event Log 50% Full (Restore not applicable) 623 Event Log 90% Full Trouble-Event Log 90% Full (Restore not applicable) 624 Event Log Overflow Trouble-Event Log Overflow (Restore not applicable) 625 Time/Date Reset Trouble-Time/Date Reset-User # (Restore not applicable) 626 Time/Date Inaccurate Trouble-Time/Date Invalid 86 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix A: Contact ID Event Code Classifications . Table 96: Contact ID Event Code Classifications (continued) # Event Type Zone 627 Program Mode Entry Trouble-Program Mode Entry (Restore not applicable) 628 Program Mode Exit Trouble-Program Mode Exit (Restore not applicable) Scheduling: 630 Schedule Change Trouble-Schedule Changed (Restore not applicable) 631 Exception Sched. Change Trouble-Esc. Sched. Changed (Restore not applicable) 632 Access Schedule Changes Trouble-Access Sched. Changed (Restore not applicable) Personnel Monitoring: 641 Senior Watch Trouble Trouble-Senior Watch Trouble 642 Latch-key Supervision Status-Latch-key Super-User # (Restore not applicable) Special Codes: 750789 These codes are used only by Protection and can be assigned any unique non-standard Event code that Pro 1 tracks. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 87 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix B: Internal Messages Appendix B: Internal Messages Table 97: Internal Messages # 1. 2. D6500 2 Output 2 SIA Output Acknowledge Printer Output Acknowledge Keypad Operation 1 1 X 0 [NYZ] OPERATOR KEYPAD OPERATION 3. Service Required X 1 [NYX] SERVICE REQUIRED 4. Set Time X 2 [NJT] TIME SET 5. Battery Missing X 9 [NYM] BATTERY MISSING 1 6. Battery Present X 10 [NYR] BATTERY PRESENT 7. Battery Bad X 11 [NYT] BATTERY LOW 8. Battery Restore X 12 [NYR] BATTERY RESTORE 9. AC Fail X 13 [NAT] AC FAIL 10. AC Restore X 14 [NAR] AC RESTORE X 15 [NVI] PAPER IN 11. 88 Internal Messages Paper In 1 1 12. Paper Out X 16 [NVO] PAPER OUT 13. Local Parameter 1 Program In X 17 [NLB] LOCAL PARM PROGRAM IN 14. Local Parameter 1 Program Successful X 18 [NLS] LOCAL PARM PROGRAM OK 15. Local Software 1 Program In X 41 [NLB] LOCAL SOFTWARE PROG IN 16. Local Software 1 Program Successful X 42 [NLS] LOCAL SOFTWARE PROG OK 17. Local Program 1 Failure X 43 [NLU] LOCAL PROGRAM FAILURE 18. Local Program 1 Denied X 44 [NLD] LOCAL PROGRAM DENIED 19. Remote Parameter Program In X 45 [NRB] REMOTE PARM PROGRAM IN 20. Remote Parameter Program Successful X 46 [NRS] REMOTE PARM PROGRAM OK 21. Remote Software Program In X 47 [NRB] REMOTE SOFTWARE PROG IN 22. Remote Software Program Successful X 48 [NRS] REMOTE PROGRAM SUCCESS 23. Remote Program Failure X 49 [NRU] REMOTE PROGRAM FAILURE 24. Remote Program 1 Denied X 50 [NRD] REMOTE PROGRAM DENIED 25. Printer On Line X 19 [NVY] PRINTER ON LINE 1 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix B: Internal Messages . Table 97: Internal Messages (continued) # Internal Messages 1 2 D6500 2 Output SIA Output Printer Output 26. Printer Off Line X 20 [NVZ] PRINTER OFF LINE 27. External PRT Error X 21 [NVT] EXTERNAL PRINTER ERROR 28. External PRT Restore X 22 [NVR] EXTERNAL PRINTER RESTORE X 21 [NVT] INTERNAL PRINTER ERROR X 22 [NVR] INTERNAL PRINTER RESTORE 29. Internal PRT Error 1 1 30. Internal PRT Restore 31. Busy Seconds bbb B [NYBbbb] BUSY SECONDS bbb% 32. COM3 Error X 30 [NYC] COMPUTER ERROR 33. COM3 Trouble X 31 [NYS] COMPUTER TROUBLE 34. COM3 Restore X 32 [NYK] COMPUTER RESTORE 35. UPS AC Fail X 33 [NUA01] UPS AC FAIL 36. UPS AC Restore X 34 [NUR01] UPS AC RESTORE 37. UPS Battery Low X 35 [NUA02] UPS BATTERY LOW 38. UPS Battery Restore X 36 [NUR02] UPS BATTERY RESTORE 39. System Reset X 37 [NYW01] SYSTEM RESET 1 40. System Default X 38 [NYG] SYSTEM DEFAULT 41. System Temperature High X 39 [NKA] SYSTEM TEMPERATURE HIGH 42. System Temperature Restore X 40 [NKR] SYSTEM TEMPERATURE RESTORE 43. Slotx/Linex (Lxx) Line Fault X 5 [NLT] PHONE LINE FAULT 44. Slotx/Linex (Lxx) Line Restore X 6 [NLR] PHONE LINE RESTORE 45. Slotx/Linex (Lxx) Line Card Trouble X 7 [NYD] LINE CARD TROUBLE 46. Slotx/Linex (Lxx) Line Card Restore X 8 [NYE] LINE CARD RESTORE 47. Slotx/Linex (Lxx) Audio In * [NLF] AUDIO IN 48. Slotx/Linex (Lxx) Audio Done L [NLE] AUDIO DONE 49. Slotx/Linex (Lxx) 1 Communication Error X 60 [NUA03] COMMUNICATION ERROR 50. Slotx/Linex (Lxx) 1 Communication Restr X 61 [NUR03] COMMUNICATION RESTORE 51. Slotx/Linex (Lxx) Data Error X 62 [NYN] DATA ERROR Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 89 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix B: Internal Messages Table 97: Internal Messages (continued) D6500 2 Output SIA Output 52. Slotx/Linex (Lxx) No Data Received X 63 [NUT04] NO DATA RECEIVED 53. Slotx/Linex (Lxx) Reset X 64 [NYW02] LINE RESET 54. Slotx/Linex (Lxx) 1 Codec Error X 65 [NUT05] CODEC ERROR 55. Slotx/Linex (Lxx) Private Call P [NUT06] PRIVATE CALL 56. Slotx/Linex (Lxx) No Call Number N [NUT07] NO CALL NUMBER 57. Slotx/Linex (Lxx) Caller Unknown U [NUT08] CALLER UNKNOWN 58. Set Date X 51 [NJD] DATE SET 59. Stop Two Way Audio X 52 [CLK] TWO WAY AUDIO STOP X 53 [NYN01] CPU DATA ERROR X 54 [NNT] NETWORK ERROR 60. 61. 90 2 Internal Messages # CPU Data Error Network Error 1 1 1 Printer Output 62. Network Restore X 55 [NNR] NETWORK RESTORE 63. Account Status Failure T B02 [NYC] COMM FAIL 64. Account Status Restore N B02 [NYK] COMM FAIL RESTR 65. Supervision Rate Changed X 66 [NCO0001] SUPERVISION RATE CHANGED 66. Switch To Intercept Mode X 88 [NCO0002] SWITCH TO INTERCEPT MODE 67. Switch to Fallback Mode X 81 [NCO0003] SWITCH TO FALLBACK MODE 68. Diable Intercept Mode X 83 [NCO0004] DISABLE INTERCEPT MODE 69. Activate Output X 84 [NCO0005] ACTIVATE OUTPUT 70. Deactivate Output X 86 [NCO0006] DEACTIVATE OUTPUT 71. C900 Reboot X 59 [NSC0001] C900 REBOOT 72. C900 Battery Low X 58 [NSC0002] C900 VOLTAGE LOW 73. C900 Battery Restore X 68 [NSC0003] C900 VOLTAGE RESTORE Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix B: Internal Messages . Table 97: 2 2 Internal Messages D6500 2 Output SIA Output Printer Output 74. C900 Switched to Intercept X 87 [NSC0004] C900 SWITCHED TO INTERCEPT 75. C900 Switched to Fallback X 82 [NSC0005] C900 SWITCHED TO FALLBACK 76. C900 Output Activated X 85 [NSC0006] C900 OUTPUT ACTIVATED 77. C900 Output Deactivated X 94 [NSC0007] C900 OUTPUT DEACTIVATED 78. C900 Input Shorted X 89 [NSC0008] C900 INPUT SHORTED 79. C900 Input Open X 90 [NSC0009] C900 INPUT OPEN 80. C900 Input Restored X 91 [NSC0010] C900 INPUT RESTORED 81. C900 Intercept Enabled X 92 [NSC0011] C900 INTERCEPT ENABLED 82. C900 Intercept Disabled X 93 [NSC0012] C900 INTERCEPT DISABLED 83. No Acknowledgement Received X 71 [NYU0001] NO ACKNOWLEDGEMENT RECEIVED 84. Not Dialing X 72 [NYU0002] NOT DIALING 85. Dialing Error X 73 [NYU0003] DIALING ERROR 86. No Response to Handshake X 74 [NYU0004] NO RESPONSE TO HANDSHAKE 87. No Response to Acknowledgement X 75 [NYU0005] NO RESPONSE TO ACK 88. 89. Message Unknown X 76 [NYU0006] MESSAGE UNKNOWN Invalid Message X 77 [NYU0007] INVALID MESSAGE 90. 30 Minutes Since Fallback Command X 95 [NMI0001] 30 MIN SINCE FALLBACK CMD 91. Alarm for Panel Substitution A D53 [Npt003AA 007] ALARM-PNL SUBST 92. Account Disable by Attack TB03 [Npt003YC 008] ACCOUNT DISABLED BY ATTACK 93. Incompatible X 99 [NIVn] INCOMPATIBLE FIRMWARE 94. Incompatible X 100 [NIUn] INCOMPATIBLE HARDWARE # 1 Internal Messages (continued) Internal message is not implemented. Output messages are abbreviated. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 91 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C:Modem4/Modem IIIa2 Messages Appendix C: Modem4/ModemIIIa² Messages For lines that are grouped, Gxx appears instead of Lxx. The GV4 (v2.x.x and higher)/B5512/B4512 send 4-digit user and point numbers. Panels using Modem4 send 4-digit Point and User data. New events added since the last revision of this document are identified as a New Message in the Comments coloumn. Comment numbers are identified in the ZONEX and Comex Translation section following this table. Table 98: 1 2 3 4 5 6 7 8 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Abort (No User) Printer: dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a h1rrlssssssaaaasIsD41t

[#aaaa|NriaAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasIsiiit
[#aaaa|Nria/idiiiAB] dd/dd tt:tt Lxx ACC aaaa ABORT BY USER +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasIiiiit
[#aaaa|Nriaa/idiiiiAB] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nriaa/idiiiiDGppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa ACCESS GRANTED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa AC FAILURE +++ACC aaaa AREA=aa h1rrlssssssaaaasPsssst
[#aaaa|NriaaAT] dd/dd tt:tt Lxx ACC aaaa AC FAILURE h1rrlssssssaaaasPsssst
[#aaaa|NAT] dd/dd tt:tt Lxx ACC aaaa AC RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss0t
[#aaaa|NriaaAR] dd/dd tt:tt Lxx ACC aaaa AC RESTORAL h1rrlssssssaaaasRsss0t
[#aaaa|NAR] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaCRppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiCRppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaCRpppp] Abort Abort (4-digit User) Access Granted Access Granted (4-digit User) Access Granted (4-digit Point) Access Granted (4-digit User / Point) AC Fail 9 AC Fail (No Area) 10 AC Restoral 11 AC Restoral (No Area) 12 Alarm from Recent Closing (2 min of close) (No User) 13 14 Alarm from Recent Closing (2 min of close) Alarm from Recent Closing (2 min of close) (No User / 4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 92 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 15 16 17 18 19 20 21 22 23 24 25 26 27 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Alarm from Recent Closing (2 min of close) (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaCRppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiCRppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa RECENT CLOSING +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiCRpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBMpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT, GROUND FAULT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaBMppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa CROSS POINT, GROUND FAULT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaBMpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaDFppp] Alarm from Recent Closing (2 min of close) (4-digit User / Point) Alarm from Recent Closing / Ground Fault (2 min of close) (No User) Alarm from Recent Closing / Ground Fault (2 min of close) Alarm from Recent Closing / Ground Fault (2 min of close) (No User / 4-digit point) Alarm from Recent Closing / Ground Fault (2 min of close) (4-digit Point) Alarm from Recent Closing / Ground Fault (2 min of close) (4-digit User / Point) Alarm Cross Point Alarm Cross Point (No Area) Alarm Cross Point (4-digit Point) Alarm Cross Point / Ground Fault Alarm Cross Point / Ground Fault (4-digit Point) Alarm Door Forced D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 93 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 28 29 30 31 32 33 34 35 36 37 38 39 40 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Alarm Door Forced (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NidiiiEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|Nria/idiiiEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/idiiiiEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaEAppp] dd/dd tt:tt Lxx ACC aaaa ALARM REPORT +++ACC aaaa EXIT ERROR, GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaEApppp] dd/dd tt:tt Lxx ACC aaaa ALARM SILENCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaFSppppt
[#aaaa|NriaaFLpppp] dd/dd tt:tt Lxx ACC aaaa ALL PTS TESTED h1rrlssssssaaaasRsssFt
[#aaaa|NTC] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaANppp] Alarm Exit Error (No User) Alarm Exit Error (No user / 4-digit Point) Alarm Exit Error (No Area) Alarm Exit Error Alarm Exit Error (4-digit Point) Alarm Exit Error (4-digit User / Point) Alarm Exit Error / Ground Fault Alarm Exit Error / Ground Fault (4-digit Point) Alarm Exit Error / Ground Fault (4-digit User / Point) Alarm Exit Error / Ground Fault (No user) Alarm Exit Error / Ground Fault (No user / 4-digit Point) Alarm Silenced (4-digit Point) 41 Analog Restoral / Sensor Dirty 42 Analog Restoral D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 94 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Analog Restoral / Sensor Dirty Printer: dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaANppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG RESTORE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaANpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaASppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaASppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=a POINT=ppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaasTspppt
[#aaaa|Nria/lvlll/vavvvASppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa SENSOR DIRTY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaASpppp] dd/dd tt:tt Lxx ACC aaaa ANALOG SERVICE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaasTppppt
[#aaaa|Nriaa/lvlll/vavvvASpppp] dd/dd tt:tt Lxx ACC aaaa WATCH MODE END +++ACC aaaa AREA=a h1rrlssssssaaaasNsD52t
[#aaaa|NriaTZ] dd/dd tt:tt Lxx ACC aaaa WATCH MODE END +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD52t
[#aaaa|Nria/idiiiTZ] dd/dd tt:tt Lxx ACC aaaa WATCH MODE END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD52t
[#aaaa|Nriaa/idiiiiTZ] dd/dd tt:tt Lxx ACC aaaa WATCH START +++ACC aaaa AREA=a h1rrlssssssaaaasNsD51t
[#aaaa|NriaTW] dd/dd tt:tt Lxx ACC aaaa WATCH START +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasNsD51t
[#aaaa|Nria/idiiiTW] dd/dd tt:tt Lxx ACC aaaa WATCH START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasNsD51t
[#aaaa|Nriaa/idiiiiTW] dd/dd tt:tt Lxx ACC aaaa BATTERY LOW h1rrlssssssaaaasTsss9t
[#aaaa|NYT] dd/dd tt:tt Lxx ACC aaaa BATTERY LOW +++ACC aaaa AREA=aa h1rrlssssssaaaasTsss9t
[#aaaa|NriaaYT] Analog Restoral (4-digit Point) Analog Restoral / Sensor Dirty (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Analog Service D6500 Mode: SIA Mode: Printer: Analog Service / Dirty Sensor D6500 Mode: SIA Mode: Printer: Analog Service (Level & Value) Analog Service (4-digit Point) Analog Service / Dirty Sensor (4-digit Point) Analog Service (4-digit Point) (Level & Value) Area Watch Ended (No user) Area Watch Ended Area Watch Ended (4-digit User) Area Watch Started (No user) Area Watch Started Area Watch Started (4-digit User) 58 Battery Low (System) 59 Battery Low (Area Specific) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 95 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: Modem4/ModemIIIa² Messages Event Device/Mode 60 Battery Missing (System) 61 Battery Restoral (System) 62 Battery Restoral (Area Specific) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 63 Battery Trouble 64 Battery Trouble (Device Specific) 65 Battery Trouble Restoral 66 Battery Trouble Restoral (Device Specific) 67 68 69 70 71 72 73 74 75 76 77 Bypass Restore (No Area) Bypass Restore Bypass Restore (4-digit Point) Bypass Restore / Fire Point (4-digit Point) Bypass Restore / Supervisory Point (4-digit Point) Bypass Restore / Waterflow Point (4-digit Point) Cancel Alarm (No Area) Cancel Alarm Cancel Alarm (No User) Cancel Alarm (4-digit User) Card Assigned by Programmer D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 96 Display/Explanation dd/dd tt:tt Lxx ACC aaaa BATTERY MISSING h1rrlssssssaaaasTsss9t
[#aaaa|NYM] dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE h1rrlssssssaaaasRsss9t
[#aaaa|NYR] dd/dd tt:tt Lxx ACC aaaa BATTERY RESTORE +++ACC aaaa AREA=aa h1rrlssssssaaaasRsss9t
[#aaaa|NriaaYR] dd/dd tt:tt Lxx ACC aaaa BATTERY TROUBLE h1rrlssssssaaaasTsss9t
[#aaaa|NYT] dd/dd tt:tt Lxx ACC aaaa BATTERY TROUBLE +++ACC aaaa SDI=dddd h1rrlssssssaaaasTsss9t
[#aaaa|NpiddddYT] dd/dd tt:tt Lxx ACC aaaa BATT TRBL REST h1rrlssssssaaaasRsss9t
[#aaaa|NYR] dd/dd tt:tt Lxx ACC aaaa BATT TRBL REST +++ACC aaaa SDI=dddd h1rrlssssssaaaasRsss9t
[#aaaa|NpiddddYR] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRBspppt
[#aaaa|NriaUUppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaUUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa FIRE POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaFUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaSUpppp] dd/dd tt:tt Lxx ACC aaaa BYPASS RESTORE +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaWUpppp] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa ID=iii h1rrlssssssaaaas\siiit
[#aaaa|NidiiiBC] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit
[#aaaa|Nria/idiiiBC] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=a h1rrlssssssaaaas\sssst
[#aaaa|NriaBC] dd/dd tt:tt Lxx ACC aaaa CANCEL ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit
[#aaaa|Nriaa/idiiiiBC] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iii-x SDI=ddd h1rrlssssssaaaasNsD30t
[#aaaa|NpidddDAiii] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 78 79 80 81 82 83 84 85 86 87 88 89 90 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Card Assigned by Programmer (4-digit User) Printer: dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD30t
[#aaaa|NpidddDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iii-x h1rrlssssssaaaasNsD30t
[#aaaa|NDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iiii h1rrlssssssaaaasNsD30t
[#aaaa|NDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER +++ACC aaaa CRD=iii-x ID=iii h1rrlssssssaaaasNsD30t
[#aaaa|NidiiiDAiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD30t
[#aaaa|NidiiiiDAiiii] dd/dd tt:tt Lxx ACC aaaa CARD ASSIGNED +++ACC aaaa BY USER h1rrlssssssaaaasNsD30t
[#aaaa|NDA] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER h1rrlssssssaaaasNsD31t
[#aaaa|NDB] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER +++ACC aaaa CRD=iii-x ID=iii h1rrlssssssaaaasNsD31t
[#aaaa|NidiiiDBiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY USER +++ACC aaaa CRD=iiii ID=iiii h1rrlssssssaaaasNsD31t
[#aaaa|NidiiiiDBiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iii-x SDI=ddd h1rrlssssssaaaasNsD31t
[#aaaa|NpidddDBiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY PROGRAMMER +++ACC aaaa CRD=iiii SDI=ddd h1rrlssssssaaaasNsD31t
[#aaaa|NpidddDBiiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iii-x h1rrlssssssaaaasNsD31t
[#aaaa|NDBiii] dd/dd tt:tt Lxx ACC aaaa CARD DELETED +++ACC aaaa BY REMOTE +++ACC aaaa CRD=iiii h1rrlssssssaaaasNsD31t
[#aaaa|NDBiiii] dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL h1rrlssssssaaaasAsD12t
[#aaaa|NYX] dd/dd tt:tt Lxx ACC aaaa CHECKSUM FAIL +++ACC aaaa SDI=ddd h1rrlssssssaaaasAsD12t
[#aaaa|NpidddYX] Card Assigned by Remote Card Assigned by Remote (4-digit User) Card Assigned by User Card Assigned by User (4-digit User) Card Assigned by User (No User) Card Deleted by User (No User) Card Deleted by User Card Deleted by User (4-digit User) Card Deleted by Programmer Card Deleted by Programmer (4-digit User) Card Deleted by Remote Card Deleted by Remote (4-digit User) 91 Checksum Fail 92 Checksum Fail (Device Specific) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 97 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Closing by Account (No Area) Printer: dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCL] dd/dd tt:tt Lxx ACC aaaa CLOSING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCL] dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCK] dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCK] dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCK] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCJ] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaCJ] dd/dd tt:tt Lxx ACC aaaa CLOSING LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCJ] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiUBppp] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|Nria/idiiiiUBppp] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/idiiiUBpppp] dd/dd tt:tt Lxx ACC aaaa COMMAND BYPASS +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/idiiiiUBpppp] dd/dd tt:tt Lxx ACC aaaa COMM FAIL +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t
[#aaaa|NphhhYC] dd/dd tt:tt Lxx ACC aaaa COMM FAIL +++ACC aaaa RG=g h1rrlssssssaaaasTsB01t
[#aaaa|NrggYC] dd/dd tt:tt Lxx ACC aaaa COMM FAIL +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasTsB01t
[#aaaa|Nrgg/pidddYC] dd/dd tt:tt Lxx ACC aaaa COMM FAIL RESTR +++ACC aaaa PH#=hh h1rrlssssssaaaasNsB01t
[#aaaa|NphhhYK] Closing by Area Closing by Area (No User) Closing by Area (4-digit User) Closing Early by Area Closing Early by Area (No User) Closing Early by Area (4-digit User) Closing Late by Area Closing Late by Area (No User) Closing Late by Area (4-digit User) Command Bypass Command Bypas (4-digit User) Command Bypas (4-digit Point) Command Bypas (4-digit User / Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Comm Fail / Phone Line D6500 Mode: SIA Mode: Printer: Comm Fail / Route Group D6500 Mode: SIA Mode: Printer: Comm Fail / Route Group (Device Specific) Comm Fail Restoral / Phone Line D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 98 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 111 112 113 114 115 116 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Comm Fail Restoral / Route Group Printer: dd/dd tt:tt Lxx ACC aaaa COMM FAIL RESTR +++ACC aaaa RG=g h1rrlssssssaaaasNsB01t
[#aaaa|NrggYK] dd/dd tt:tt Lxx ACC aaaa COMM FAIL RESTR +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasNsB01t
[#aaaa|Nrgg/pidddYK] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa PH#=hh h1rrlssssssaaaasTsB01t
[#aaaa|NphhhYS] dd/dd tt:tt Lxx ACC aaaa COMM TROUBLE +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasTsB01t
[#aaaa|Nrgg/pidddYS] dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa PH#=hh h1rrlssssssaaaasNsB01t
[#aaaa|NphhhYK] dd/dd tt:tt Lxx ACC aaaa COMM TRBL RESTR +++ACC aaaa RG=g SDI=ddd h1rrlssssssaaaasNsB01t
[#aaaa|Nrgg/pidddYK] dd/dd tt:tt Lxx ACC aaaa STATUS REPORT h1rrlssssssaaaasSsssst
[#aaaa|NYY] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY CUSTOM FUNCTION +++ACC aaaa CUST.FX=fff AREA=aa ICF=fff h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/cffffCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY SKED +++ACC aaaa CUST.FX=fff AREA=aa SKED=kkk h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/aikkkCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iii h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/idiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa ID=iiii h1rrlssssssaaaasNsD39t
[#aaaa|Nriaa/idiiiiCXfff] dd/dd tt:tt Lxx ACC aaaa CUSTOM FUNCTION +++ACC aaaa BY USER +++ACC aaaa CUST.FX=fff AREA=aa h1rrlssssssaaaasNsD39t
[#aaaa|NriaaCXfff] dd/dd tt:tt Lxx ACC aaaa DATE CHANGED +++ACC aaaa ID=iii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiJD] dd/dd tt:tt Lxx ACC aaaa DATE CHANGED h1rrlssssssaaaasNsD07t
[#aaaa|NJD] dd/dd tt:tt Lxx ACC aaaa DATE CHANGED +++ACC aaaa ID=iiii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiiJD] dd/dd tt:tt Lxx ACC aaaa REST-DR CLOSED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaDHppp] dd/dd tt:tt Lxx ACC aaaa REST-DR CLOSED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaDHpppp] Comm Fail Restoral / Route Group (Device Specific) Comm Trouble / Phone Line Comm Trouble / Route Group (Device Specific) Comm Trouble Restoral / Phone Line Comm Trouble Restoral / Route Group (Device Specific) 117 Create Status Report 118 Custom Function by Custom Fuction 119 120 121 122 123 D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : Custom Function by SKED Custom Function by User D6500 Mode: SIA Mode: Printer : Custom Function by User (4-digit User) Custom Function by User (No User) Date Changed by User Date Changed 125 Date Changed by User (4-digit User) 127 D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : 124 126 D6500 Mode: SIA Mode: Printer: Door Closed / Restoral Door Closed / Restoral (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 99 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 128 129 130 131 132 133 134 135 136 137 138 139 140 141 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Door Cycled Printer: Door Cycled by Programmer D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaaAGspppt
[#aaaa|Nria/pidddDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/pidddDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|Nria/idiiiiDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|Nriaa/idiiiiDGpppp] dd/dd tt:tt Lxx ACC aaaa DOOR CYCLED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDGppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaaALspppt
[#aaaa|Nria/pidddDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/pidddDYpppp] Door Cycled by Programmer (4-digit Point) Door Cycled by Remote Door Cycled by Remote (4-digit Point) Door Cycled by User Door Cycled by User (4-digit User) Door Cycled by User (4-digit Point) Door Cycled by User (4-digit User / Point) Door Cycled by User (No User) Door Locked / Automatic Door Locked / Automatic (4-digit Point) Door Locked by Programmer Door Locked by Programmer (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 100 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Door Locked by Remote Printer: dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BYREMOTE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=a POINT=ppp SKED=kkk h1rrlssssssaaaaALspppt
[#aaaa|Nria/aikkkDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/aikkkDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|Nria/idiiiDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/idiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|Nriaa/idiiiiDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaALspppt
[#aaaa|NriaDYppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa DOOR LOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaALppppt
[#aaaa|NriaaDYpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDEppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDEpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAGspppt
[#aaaa|NriaDXppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAGppppt
[#aaaa|NriaaDXpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] Door Locked by Remote (4-digit Point) Door Locked by SKED Door Locked by SKED (4-digit Point) Door Locked by User Door Locked by User (4-digit Point) Door Locked by User (4-digit User / Point) Door Locked by User (No User) Door Locked by User (No User / 4-digit Point) Door Locked (4-digit Point) Door Request To Enter Door Request To Enter (4-digit Point) Door Request To Exit Door Request To Exit (4-digit Point) Door Request To Enter Denied (Door Secured) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer : D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 101 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Door Request To Enter Denied (Door Secured) (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO ENTR +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa REQUEST TO EXIT +++ACC aaaa DENIED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaaASspppt
[#aaaa|Nria/pidddDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/pidddDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] Door Request To Enter Denied (Interlock) Door Request To Enter Denied (Interlock) (4-digit Point) Door Request To Exit Denied (Door Secured) Door Request To Exit Denied (Door Secured) (4-digit Point) Door Request To Exit Denied (Interlock) Door Request To Exit Denied (Interlock) (4-digit Point) Door Secured Door Secured (4-digit Point) Door Secured / Automatic Door Secured / Automatic (4-digit Point) Door Secured by Programmer Door Secured by Programmer (4-digit Point) Door Secured by Remote Door Secured by Remote (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 102 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Door Secured by SKED Printer: dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY SKED +++ACC aaaa AREA=a POINT=ppp SKED=kkk h1rrlssssssaaaaASspppt
[#aaaa|Nria/aikkkDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/aikkkDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|Nria/idiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|Nria/idiiiiDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/idiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|Nriaa/idiiiiDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaASspppt
[#aaaa|NriaDCppp] dd/dd tt:tt Lxx ACC aaaa DOOR SECURED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaASppppt
[#aaaa|NriaaDCpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa AUTOMATIC +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaaAUspppt
[#aaaa|Nria/pidddDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY PROGRAMMER +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/pidddDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] Door Secured by SKED (4-digit Point) Door Secured by User Door Secured by User (4-digit User) Door Secured by User (4-digit Point) Door Secured by User (4-digit User / Point) Door Secured by User (No User) Door Secured by User (No User / 4-digit Point) Door Unlocked Door Unlocked (4-digit Point) Door Unlocked / Automatic Door Unlocked / Automatic (4-digit Point) Door Unlocked by Programmer Door Unlocked by Programmer (4-digit Point) Door Unlocked by Remote D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 103 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 187 188 189 190 191 192 193 194 195 196 197 198 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Door Unlocked by Remote (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY REMOTE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=a POINT=ppp SKED=kkk h1rrlssssssaaaaAUspppt
[#aaaa|Nria/aikkkDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY SKED +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/aikkkDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|Nria/idiiiDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a ID=iiii POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|Nria/idiiiiDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/idiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|Nriaa/idiiiiDOpppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaAUspppt
[#aaaa|NriaDOppp] dd/dd tt:tt Lxx ACC aaaa DOOR UNLOCKED +++ACC aaaa BY USER +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaAUppppt
[#aaaa|NriaaDOpppp] dd/dd tt:tt Lxx ACC aaaa DURESS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasDsiiit
[#aaaa|Nria/idiiiHA] dd/dd tt:tt Lxx ACC aaaa DURESS +++ACC aaaa ID=iii h1rrlssssssaaaasDsiiit
[#aaaa|NidiiiHA] dd/dd tt:tt Lxx ACC aaaa DURESS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasDiiiit
[#aaaa|Nriaa/idiiiiHA] dd/dd tt:tt Lxx ACC aaaa CLOSING EARLY h1rrlssssssaaaasCsssst
[#aaaa|NCK] dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN h1rrlssssssaaaasOsssst
[#aaaa|NOK] dd/dd tt:tt Lxx ACC aaaa EQUIPMENT FAIL +++ACC aaaa SDI=ddd COND=nnn h1rrlssssssaaaasTsD29t
[#aaaa|NpidddIAnnn] dd/dd tt:tt Lxx ACC aaaa EQUIP RESTORAL +++ACC aaaa SDI=ddd COND=nnn h1rrlssssssaaaasRsD29t
[#aaaa|NpidddIRnnn] Door Unlocked by SKED Door Unlocked by SKED (4-digit Point) Door Unlocked by User Door Unlocked by User (4-digit User) Door Unlocked by User (4-digit Point) Door Unlocked by User (4-digit User / Point) Door Unlocked by User (No User) Door Unlocked by User (No User / 4-digit Point) Duress Duress (No Area) Duress (4-digit User) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 199 Early to Close (No Area) 200 Early To Open (No Area) 201 Equipment Fail D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Equipment Restoral D6500 Mode: SIA Mode: Printer: 202 D6500 Mode: SIA Mode: 104 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 203 204 205 206 207 208 209 210 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Extend Close Time by Area (No User) Printer: dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nria/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=a ID=iii TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nria/idiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTN CLOSE TIME +++ACC aaaa AREA=aa ID=iiii TIME=hh:mm h1rrlssssssaaaasTsD26t
[#aaaa|Nriaa/idiiii/tihhmmCE] dd/dd tt:tt Lxx ACC aaaa EXTERNAL DEVICE +++ACC aaaa EXT.DEV=ddd COND=nnn h1rrlssssssaaaasNsD50t
[#aaaa|NpidddEXnnn] dd/dd tt:tt Lxx ACC aaaa EXTRA ACCOUNT +++ACC aaaa PATH=ppp COND=nnn h1rrlssssssaaaasNsD46t
[#aaaa|NpapppXAnnn] dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXEppp] dd/dd tt:tt Lxx ACC aaaa EXTRA POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXEpppp] dd/dd tt:tt Lxx ACC aaaa EXTRA RF POINT +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD16t
[#aaaa|NpidddXF] dd/dd tt:tt Lxx ACC aaaa EXTRA RF POINT h1rrlssssssaaaasTsD16t
[#aaaa|NXF] dd/dd tt:tt Lxx ACC aaaa BAD CALL TO RAM h1rrlssssssaaaasTsF02t
[#aaaa|NRA] dd/dd tt:tt Lxx ACC aaaa FAIL TO CLOSE +++ACC aaaa AREA=a h1rrlssssssaaaasTsssEt
[#aaaa|NriaCI] dd/dd tt:tt Lxx ACC aaaa DELNQNT CLOSING +++ACC aaaa AREA=a h1rrlssssssaaaasTsssEt
[#aaaa|NriaCD] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-INTERLOCK +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-DOOR SECURE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR UNLOCKED-DOOR SECURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNsD35t
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] Extend Close Time by Area Extend Close Time by Area (4-digit User) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: External Device D6500 Mode: SIA Mode: Printer: Extra Account D6500 Mode: SIA Mode: Printer: Extra Point D6500 Mode: SIA Mode: Printer: Extra Point (4-digit Point) Extra RF Point D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 211 Extra RF Point (7112 Only) 212 Fail To Call RPS 213 Fail To Close by Area D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Fail To Close / Delinquent D6500 Mode: SIA Mode: Printer: 214 215 216 217 218 219 Fail to Execute / Door Unlocked (Interlock) Fail to Execute / Door Unlocked (Interlock) (4-digit Point) Fail to Execute / Door Unlocked (Door Secured) Fail to Execute / Door Unlocked (Door Secured) (4-digit Point) Fail to Execute / Door Cycled (Door Secured) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 105 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Fail to Execute / Door Cycled (Door Secured) (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-DOOR SECURED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-INTERLOCK +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDKppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa DOOR CYCLED-INTERLOCK +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDKpppp] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa INCORRECT RESPONSE +++ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t
[#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO EXECUTE +++ACC aaaa NO RESPONSE +++ACC aaaa SDI=ddd h1rrlssssssaaaasNsD34t
[#aaaa|NpidddYX] dd/dd tt:tt Lxx ACC aaaa FAIL TO OPEN +++ACC aaaa AREA=a h1rrlssssssaaaasTsssEt
[#aaaa|NriaOI] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NFAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFMppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NFMppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFMpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaFAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaFApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaKAppp] Fail to Execute / Door Cycled (Interlock) Fail to Execute / Door Cycled (Interlock) (4-digit Point) Fail to Execute (Incorrect Response) Fail to Execute (No Response) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Fail To Open by Area D6500 Mode: SIA Mode: Printer: Fire Alarm D6500 Mode: SIA Mode: Printer: Fire Alarm (4-digit Point) Fire Alarm (2112/2212) Fire Alarm / Cross Point Fire Alarm / Cross Point (2112/2212) Fire Alarm / Cross point (4-digit Point) Fire Alarm / Smoke Detector Fire Alarm / Smoke Detector (4-digit Point) Fire Alarm / High Temp Sensor D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 106 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 7 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Fire Alarm / High Temp Sensor (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaKApppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasFspppt
[#aaaa|NriaSAppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasFppppt
[#aaaa|NriaaSApppp] dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaas\siiit
[#aaaa|Nria/idiiiFC] dd/dd tt:tt Lxx ACC aaaa FIRE CANCEL +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit
[#aaaa|Nriaa/idiiiiFC] dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ACC aaaa AREA=aPOINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaFYppp] dd/dd tt:tt Lxx ACC aaaa MISSING FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFHppp] dd/dd tt:tt Lxx ACC aaaa FIRE ALM RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFHpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TBL RESTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFJppp] dd/dd tt:tt Lxx ACC aaaa FIRE TBL RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFJpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFSppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRVISION +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFVppp] Fire Alarm / Waterflow Sensor Fire Alarm / Waterflow Sensor (4-digit Point) Fire Cancel Fire Cancel (4-digit User) Fire Missing Fire Missing (4-digit Point) Fire Alarm Restoral (No Area) Fire Alarm Restoral Fire Alarm Restoral(4-digit Point) Fire Restoral (Trouble/Missing/Supervision) Fire Restoral (Trouble/Missing/Supervision) (4-digit Point) Fire Supervision Fire Supervision (4-digit Point) Fire Supervision / Waterflow Sensor Fire Supervision / Waterflow Sensor (4-digit Point) Fire Supervision Restore D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 7 107 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Fire Supervision Restore (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFVpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasEspppt
[#aaaa|NriaFVppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV REST +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasEppppt
[#aaaa|NriaaFVpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFWppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFWppp] dd/dd tt:tt Lxx ACC aaaa FIRE SUPRV TRBL +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFWpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFQpppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaHsspppt
[#aaaa|NriaFQppp] dd/dd tt:tt Lxx ACC aaaa FIR SUPR TR RES +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaHsppppt
[#aaaa|NriaaFQpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp Fire Supervision Restore / Waterflow Sensor Fire Supervision Restore / Waterflow Sensor (4-digit Point) Fire Supervision Trouble Fire Supervision Trouble (4-digit Point) Fire Supervision Trouble / Waterflow Sensor Fire Supervision Trouble / Waterflow Sensor (4-digit Point) Fire Supervision Trouble Restore Fire Supervision Trouble Restore (4-digit Point) Fire Supervision Trouble Restore / Waterflow Sensor Fire Supervision Trouble Restore / Waterflow Sensor (4-digit Point) Fire Trouble Fire Trouble (4-digit Point) Fire Trouble / Smoke Detector Fire Trouble / Smoke Detector (4-digit Point) Fire Trouble / High Temp Sensor D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 108
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaKTppp] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 7 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 268 269 270 271 272 273 274 275 276 277 278 279 280 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Fire Trouble / High Temp Sensor (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaKTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaSTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaSTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGsspppt
[#aaaa|NriaFTppp] dd/dd tt:tt Lxx ACC aaaa FIRE TROUBLE +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGsppppt
[#aaaa|NriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ACC aaaa AREA=a h1rrlssssssaaaasRsssFt
[#aaaa|NriaFK] dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasRsssFt
[#aaaa|Nria/idiiiFK] dd/dd tt:tt Lxx ACC aaaa FIRE WALK END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiFK] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiFI] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiFI] dd/dd tt:tt Lxx ACC aaaa FIRE WALK START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt
[#aaaa|NriaFI] dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FRC CLOSE EARLY h1rrlssssssaaaasCsssst
[#aaaa|NCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE h1rrlssssssaaaasCsssst
[#aaaa|NCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] dd/dd tt:tt Lxx ACC aaaa FORC CLOSE LATE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] Fire Trouble / Waterflow Sensor Fire Trouble / Waterflow Sensor (4-digit Point) Fire Trouble / Ground Fault Fire Trouble / Ground Fault (4-digit Point) Fire Walk End (No User) Fire Walk End Fire Walk End (4-digit User) Fire Walk Start Fire Walk Start (4-digit User) Fire Walk Start (No User) Force Close Early by Area Force Close Early by Area (4-digit User) 281 Force Close Early (7112 Only) 282 Force Close Late (7112 Only) 283 Force Close Late by Area 284 Force Close Late by Area (4-digit User) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 109 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Force Close Perimeter Delay by Area (No User) Printer: dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR DLAY +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNF] dd/dd tt:tt Lxx ACC aaaa F CLOSE PR INST +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNF] dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED CLOSE +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiCF] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXWppp] dd/dd tt:tt Lxx ACC aaaa FORCED POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXWpppp] dd/dd tt:tt Lxx ACC aaaa GAS ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaGApppp] dd/dd tt:tt Lxx ACC aaaa GAS ALARM REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaGHpppp] dd/dd tt:tt Lxx ACC aaaa GAS CANCEL +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaas\iiiit
[#aaaa|Nriaa/idiiiiGC] dd/dd tt:tt Lxx ACC aaaa GAS MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt
[#aaaa|NriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa GAS SUPERVISORY +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaGSpppp] dd/dd tt:tt Lxx ACC aaaa GAS SUPV REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaGJpppp] dd/dd tt:tt Lxx ACC aaaa GAS TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaGTpppp] Force Close Perimeter Delay by Area Force Close Perimeter Delay by Area (4-digit User) Force Close Perimeter Instant by Area (No User) Force Close Perimeter Instant by Area Force Close Perimeter Instant by Area (4-digit User) Force Close by Area (No Area) Force Close by Area Force Close by Area (4-digit User) Force Point Force Point (4-digit Point) Gas Alarm (4-digit Point) Gas Alarm Restore (4-digit Point) Gas Cancel (4-digit User) Gas Missing (4-digit Point) Gas Supervisory (4-digit Point) Gas Supervisory Restore (4-digit Point) Gas Trouble (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 110 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message New Message New Message New Message New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 303 304 305 306 307 308 309 310 311 312 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Comments Gas Trouble Restore (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa GAS TRBL REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaGJpppp] dd/dd tt:tt Lxx ACC aaaa HIGH TEMP ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaKApppp] dd/dd tt:tt Lxx ACC aaaa HIGH TEMP REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaKHpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasDppppt
[#aaaa|NriaaHApppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt
[#aaaa|NriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaHRpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP SUPV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaHSpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP SU REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaHRpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaHTpppp] dd/dd tt:tt Lxx ACC aaaa HOLD-UP TR REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaHJpppp] dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN h1rrlssssssaaaasOsssst
[#aaaa|NOJ] dd/dd tt:tt Lxx ACC aaaa LISTEN IN +++ACC aaaa TIME=hh:mm h1rrlssssssaaaas*sssst
[#aaaa|NtihhmmLF] dd/dd tt:tt Lxx ACC aaaa LOG OVERFLOW h1rrlssssssaaaasAsD01t
[#aaaa|NJO] dd/dd tt:tt Lxx ACC aaaa LOG THRESHOLD h1rrlssssssaaaasTsD01t
[#aaaa|NJL] dd/dd tt:tt Lxx ACC aaaa LOW SIGNAL LEVL +++ACC aaaa LEVEL=lll PATH=ppp h1rrlssssssaaaasNsD48t
[#aaaa|Nlvlll/papppXL] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasLspppt
[#aaaa|NriaZAppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMPERATURE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasLppppt
[#aaaa|NriaaZApppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRLspppt
[#aaaa|NriaZRppp] dd/dd tt:tt Lxx ACC aaaa LOW TEMP RESTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRLppppt
[#aaaa|NriaaZRpppp] New Message High Temp Alarm (4-digit Point) High Temp Alarm Restore (4-digit Point) Hold-Up Alarm (4-digit Point) Hold-Up Missing (4-digit Point) Hold-Up Restore (4-digit Point) Hold-Up Supervisory (4-digit Point) Hold-Up Supervisory Restore (4-digit Point) Hold-Up Trouble (4-digit Point) Hold-Up Trouble Restore (4-digit Point) 313 Late To Open (7112 Only) 314 Listen In D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 315 Log Overflow 316 Log Threshold 317 Low Signal Strength D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Low Temperature Alarm D6500 Mode: SIA Mode: Printer: 318 319 320 321 Low Temperature Alarm (4-digit Point) Low Temperature Restoral Low Temperature Restoral (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 New Message New Message New Message New Message New Message New Message New Message New Message New Message 111 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 322 323 324 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Comments Medical Alarm by User (4-digit User) Printer: dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM +++ACC aaaa ID=iiii h1rrlssssssaaaasUiiiit
[#aaaa|NidiiiiMA] dd/dd tt:tt Lxx ACC aaaa MEDICAL ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/MApppp] dd/dd tt:tt Lxx ACC aaaa MED ALARM REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|Nriaa/MHpppp] dd/dd tt:tt Lxx ACC aaaa MEMORY FAIL h1rrlssssssaaaasAsD13t
[#aaaa|NYX] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NUZppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaUZppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaXMppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaXMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaCMppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaCMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|Nria/idiiiCMppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiCMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa RECENT CLOSING +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiiCMpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|NriaEZppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|NriaaEZpppp] New Message Medical Alarm by Point (4-digit Point) Medical Alarm Restore (4-digit User / Point) 325 Memory Fail 326 Missing Alarm (2212) 327 328 329 330 331 332 333 334 335 336 337 Missing Alarm Missing Alarm (4-digit Point) Missing Alarm / Cross Point Missing Alarm / Cross Point (4-digit Point) Missing Alarm from Recent Closing (2 min of close) (No User) Missing Alarm from Recent Closing (2 min of close) (No User / 4-digit Point) Missing Alarm from Recent Closing (2 min of close) Missing Alarm from Recent Closing (2 min of close) (4-digit Point) Missing Alarm from Recent Closing (2 min of close) (4-digit User / Point) Missing Alarm Exit Error (No User) Missing Alarm Exit Error (No User / 4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 112 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Missing Alarm Exit Error Printer: dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=a ID=iii POINT=ppp h1rrlssssssaaaasMspppt
[#aaaa|Nria/idiiiEZppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING ALARM +++ACC aaaa EXIT ERROR +++ACC aaaa AREA=aa ID=iiii POINT=pppp h1rrlssssssaaaasMppppt
[#aaaa|Nriaa/idiiiiEZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt
[#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt
[#aaaa|NriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaGMspppt
[#aaaa|NriaFZppp] dd/dd tt:tt Lxx ACC aaaa MISS FIR SUPRVN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaGMppppt
[#aaaa|NriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa MISS GAS SUPV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt
[#aaaa|NriaaGSpppp] dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaMTspppt
[#aaaa|NriaBZppp] dd/dd tt:tt Lxx ACC aaaa MISSING SUPRVSN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaMTppppt
[#aaaa|NriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasVsD10t
[#aaaa|NidiiiUY] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasVsD10t
[#aaaa|NidiiiiUY] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasVspppt
[#aaaa|NriaUYppp] dd/dd tt:tt Lxx ACC aaaa MISSING TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasVppppt
[#aaaa|NriaaUYpppp] dd/dd tt:tt Lxx ACC aaaa NETWORK COND +++ACC aaaa PATH=ppp COND=nnn h1rrlssssssaaaasNsD44t
[#aaaa|NpapppNCnnn] Missing Alarm Exit Error (4-digit Point) Missing Alarm Exit Error (4-digit User / Point) Missing Fire Supervision Missing Fire Supervision (4-digit Point) Missing Fire Supervision / Waterflow Sensor Missing Fire Supervision / Waterflow Sensor (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Missing Gas Supervison D6500 Mode: SIA Mode: Printer: Missing Supervision D6500 Mode: SIA Mode: Printer: Missing Supervision (4-digit Point) Missing Trouble (2212) Missing Trouble from Keyfob Missing Trouble from Keyfob (4-digit User) Missing Trouble Missing Trouble (4-digit Point) Network Condition D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message 7 113 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 114 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Network Failure Printer: dd/dd tt:tt Lxx ACC aaaa NETWORK FAIL +++ACC aaaa PATH=ppp COND=nnn h1rrlssssssaaaasNsD42t
[#aaaa|NpapppNTnnn] dd/dd tt:tt Lxx ACC aaaa NETWORK FAIL +++ACC aaaa SDI=dddd COND=nnn h1rrlssssssaaaasNsD42t
[#aaaa|NpiddddNTnnn] dd/dd tt:tt Lxx ACC aaaa NETWORK RESTORE +++ACC aaaa PATH=ppp COND=nnn h1rrlssssssaaaasNsD43t
[#aaaa|NpapppNRnnn] dd/dd tt:tt Lxx ACC aaaa NETWORK RESTORE +++ACC aaaa SDI=dddd COND=nnn h1rrlssssssaaaasNsD43t
[#aaaa|NpiddddNRnnn] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDIppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDZppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDWppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDVppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDPppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-UNK ID +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|NriaDDppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=a CRD=iii-x POINT=ppp h1rrlssssssaaaaADspppt
[#aaaa|Nria/idiiiDQppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-UNK ID +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|NriaaDDpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDQpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDZpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDWpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDVpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iii-x POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiDPpppp] Network Failure (4-digit Device) Network Restoral Network Restoral (4-digit Device) No Entry (Anti-Passback) No Entry (Door Secured) No Entry (Interlock Deny) No Entry (No Rights in Area) No Entry (Outside Time Window) No Entry (Unknown ID) No Entry (Wrong Arming State) No Entry (Unknown ID) (4-digit Point) No Entry (Wrong Arming State) (4-digit Point) No Entry (Anti-Passback) (4-digit Point) No Entry (Door Secured) (4-digit Point) No Entry (Interlock Deny) (4-digit Point) No Entry (No Rights in Area) (4-digit Point) No Entry (Outside Time Window) (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation No Entry (Anti-Passback) (4-digit User / Point) Printer: dd/dd tt:tt Lxx ACC aaaa NO ENTRY-PASSBK +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDIpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-SECURE +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDZpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-INTRLK +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDWpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-LEVEL +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDVpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-TIME +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDPpppp] dd/dd tt:tt Lxx ACC aaaa NO ENTRY-ARMED +++ACC aaaa AREA=aa CRD=iiii POINT=pppp h1rrlssssssaaaaADppppt
[#aaaa|Nriaa/idiiiiDQpppp] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOP] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOR] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|NidiiiOR] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOP] dd/dd tt:tt Lxx ACC aaaa OPENING REPORT +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOP] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOR] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOR] dd/dd tt:tt Lxx ACC aaaa OPEN FROM ALARM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOR] dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOK] dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOK] No Entry (Door Secured) (4-digit User / Point) No Entry (Interlock Deny) (4-digit User / Point) No Entry (No Rights in Area) (4-digit User / Point) No Entry (Outside Time Window) (4-digit User / Point) No Entry (Wrong Arming State) (4-digit User / Point) Opening by Account (2112/2212) Opening by Account Opening by Account from Alarm (2212) Opening by Account from Alarm (No Area) Opening by Area Opening by Area (No User) Opening by Area (4-digit User) Opening by Area from Alarm (No User) Opening by Area from Alarm Opening by Area from Alarm (4-digit User) Opening Early by Area Opening Early by Area (No User) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 115 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 116 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Opening Early by Area (4-digit User) Printer: dd/dd tt:tt Lxx ACC aaaa EARLY TO OPEN +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOK] dd/dd tt:tt Lxx ACC aaaa OP ERLY FRM-ALM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOH] dd/dd tt:tt Lxx ACC aaaa OP ERLY FRM-ALM +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOH] dd/dd tt:tt Lxx ACC aaaa OP ERLY FRM-ALM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOH] dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOJ] dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOJ] dd/dd tt:tt Lxx ACC aaaa LATE TO OPEN +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOJ] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasOsiiit
[#aaaa|Nria/idiiiOL] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=a h1rrlssssssaaaasOsssst
[#aaaa|NriaOL] dd/dd tt:tt Lxx ACC aaaa OP LATE FRM-ALM +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasOiiiit
[#aaaa|Nriaa/idiiiiOL] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasTsD47t
[#aaaa|NOUuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TROUBLE +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasTsD47t
[#aaaa|NOUuuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuu h1rrlssssssaaaasRsD47t
[#aaaa|NOVuuu] dd/dd tt:tt Lxx ACC aaaa OUTPUT-TRBL RST +++ACC aaaa OUTPUT=uuuu h1rrlssssssaaaasRsD47t
[#aaaa|NOVuuuu] dd/dd tt:tt Lxx ACC aaaa PANIC ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|Nriaa/PApppp] dd/dd tt:tt Lxx ACC aaaa PANIC RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|Nriaa/PHpppp] dd/dd tt:tt Lxx ACC aaaa PARAMS CHANGED h1rrlssssssaaaasNsD02t
[#aaaa|NYG] dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM h1rrlssssssaaaasTsD15t
[#aaaa|NYF] Opening Early by Area from Alarm (No User) Opening Early by Area from Alarm Opening Early by Area from Alarm (4-digit User) Opening Late by Area Opening Late by Area (No User) Opening Late by Area (4-digit User) Opening Late by Area from Alarm Opening Late by Area from Alarm (No User) Opening Late by Area from Alarm (4-digit User) Output State Output State (4-digit Output) Output State Restore Output State Restore (4-digit Output) Panic Alarm (4-digit Point) Panic Restore (4-digit Point) 406 Parameters Changed 407 Parameter Checksum Fail D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 408 409 410 411 412 413 414 415 416 417 418 419 420 421 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Parameter Checksum Fail (Device Specific) Printer: dd/dd tt:tt Lxx ACC aaaa PARMS BAD CKSUM +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD15t
[#aaaa|NpidddYF] dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM DLAY ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNM] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|NidiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasCsiiit
[#aaaa|Nria/idiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa AREA=a h1rrlssssssaaaasCsssst
[#aaaa|NriaNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNL] dd/dd tt:tt Lxx ACC aaaa PERM INST ARMED +++ACC aaaa USER DEFINED +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasCiiiit
[#aaaa|Nriaa/idiiiiNM] dd/dd tt:tt Lxx ACC aaaa PHONE LINE FAIL +++ACC aaaa PHONE LINE=1 h1rrlssssssaaaasTsssBt
[#aaaa|NLT1] dd/dd tt:tt Lxx ACC aaaa PHONE LINE FAIL +++ACC aaaa PHONE LINE=2 h1rrlssssssaaaasTsssCt
[#aaaa|NLT2] dd/dd tt:tt Lxx ACC aaaa PHONE LINE FAIL +++ACC aaaa GROUND FAULT +++ACC aaaa PHONE LINE=1 h1rrlssssssaaaasTsssBt
[#aaaa|NLT1] dd/dd tt:tt Lxx ACC aaaa PHONE LINE FAIL +++ACC aaaa GROUND FAULT +++ACC aaaa PHONE LINE=2 h1rrlssssssaaaasTsssCt
[#aaaa|NLT2] dd/dd tt:tt Lxx ACC aaaa PHONE RESTORAL +++ACC aaaa PHONE LINE=1 h1rrlssssssaaaasRsssBt
[#aaaa|NLR1] dd/dd tt:tt Lxx ACC aaaa PHONE RESTORAL +++ACC aaaa PHONE LINE=2 h1rrlssssssaaaasRsssCt
[#aaaa|NLR2] dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE h1rrlssssssaaaasTsssDt
[#aaaa|NET] dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE +++ACC aaaa AREA=aa h1rrlssssssaaaasTsssDt
[#aaaa|NriaaET] dd/dd tt:tt Lxx ACC aaaa PT BUS TROUBLE +++ACC aaaa GROUND FAULT h1rrlssssssaaaasTsssDt
[#aaaa|NET] Perimeter Delay by Area (4-digit User) Perimeter Delay by Area (User Defined) (4-digit User) Perimeter Instant (2112/2212) Perimeter Instant by Area Perimeter Instant by Area (No User) Perimeter Instant by Area (4-digit User) Perimeter Instant by Area (User Defined) (4-digit User) Phone Line Fail (Line 1) Phone Line Fail (Line2) Phone Line Fail / Ground Fault (Line 1) Phone Line Fail / Ground Fault (Line 2) Phone Line Restoral (Line 1) Phone Line Restoral (Line 2) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: 422 Point Bus Fail (No Area) 423 Point Bus Fail D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Point Bus Fail / Ground Fault D6500 Mode: SIA Mode: Printer: 424 D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 117 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation 425 Point Bus Restoral (No Area) 426 Point Bus Restoral Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL h1rrlssssssaaaasRsssDt
[#aaaa|NER] dd/dd tt:tt Lxx ACC aaaa PT BUS RESTORAL +++ACC aaaa AREA=aa h1rrlssssssaaaasRsssDt
[#aaaa|NriaaER] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NUBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaFBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa FIRE POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaFBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaSBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa SUPERVISORY POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaSBpppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaWBppp] dd/dd tt:tt Lxx ACC aaaa POINT BYPASS +++ACC aaaa WATERFLOW POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaWBpppp] dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasCspppt
[#aaaa|NriaCZppp] dd/dd tt:tt Lxx ACC aaaa POINT CLOSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasCppppt
[#aaaa|NriaaCZpppp] dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasOspppt
[#aaaa|NriaOZppp] dd/dd tt:tt Lxx ACC aaaa POINT OPENING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasOppppt
[#aaaa|NriaaOZpppp] dd/dd tt:tt Lxx ACC aaaa BAD 9112 PACKET h1rrlssssssaaaasXsssst
[#aaaa|N00] dd/dd tt:tt Lxx ACC aaaa PRINTR-OFF LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVZ] 427 428 429 430 431 432 433 434 435 436 437 438 439 Point Bypass (2112/2212) Point Bypass Point Bypass (4-digit Point) Point Bypass / Fire Point Bypass / Fire (4-digit Point) Point Bypass / Supervisory Point Bypass / Supervisory (4-digit Point) Point Bypass / Waterflow Point Bypass / Waterflow (4-digit Point) Point Closing Point Closing (4-digit Point) Point Opening Point Opening (4-digit Point) 440 Point Status Report (7112 only) 441 Printer Status / Off Line D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 118 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 7 7 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 442 443 444 445 446 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Printer Status / On Line Printer: Printer Status / Paper In D6500 Mode: SIA Mode: Printer: Printer Status / Paper Out D6500 Mode: SIA Mode: Printer: Programmer Bypass D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa PRINTER-ON LINE +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVY] dd/dd tt:tt Lxx ACC aaaa PRINTR-PAPER IN +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVI] dd/dd tt:tt Lxx ACC aaaa PRNTR-PAPER OUT +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsssst
[#aaaa|NpidddVO] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ACC aaaa AREA=a POINT=ppp SDI=ddd h1rrlssssssaaaasNspppt
[#aaaa|Nria/pidddUBppp] dd/dd tt:tt Lxx ACC aaaa PROGRAMR BYPASS +++ACC aaaa AREA=aa POINT=pppp SDI=ddd h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/pidddUBpppp] dd/dd tt:tt Lxx ACC aaaa RE-BOOT h1rrlssssssaaaasNsD14t
[#aaaa|NRR] dd/dd tt:tt Lxx ACC aaaa RE-BOOT +++ACC aaaa SDI=dddd COND=012 +++ACC aaaa xxxxxxxx Vx.xx h1rrlssssssaaaasNsD14t
[#aaaa|NpiddddRR012] dd/dd tt:tt Lxx ACC aaaa RE-BOOT +++ACC aaaa SDI=dddd COND=013 +++ACC aaaa xxxxxxxx Vx.xx h1rrlssssssaaaasNsD14t
[#aaaa|NpidddRR013] dd/dd tt:tt Lxx ACC aaaa RE-BOOT +++ACC aaaa SDI=ddd h1rrlssssssaaaasNsD14t
[#aaaa|NpidddRR] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD22t
[#aaaa|NpidddROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrr h1rrlssssssaaaasNsD24t
[#aaaa|NROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrr SKED=kkk h1rrlssssssaaaasNsD20t
[#aaaa|NaikkkROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiiROrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD22t
[#aaaa|NpidddROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD24t
[#aaaa|NROrrrr] Programmer Bypass (4-digit Point) 447 Re-Boot 448 Re-Boot / Power Up (4-digit Device) (Version text) 449 450 451 452 453 454 455 456 457 Re-Boot / Firmware Update (4-digit Device) (Version text / New Version) Re-Boot (Device Specific) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Relay Reset by Programmer D6500 Mode: SIA Mode: Printer: Relay Reset by Remote D6500 Mode: SIA Mode: Printer: Relay Reset by SKED D6500 Mode: SIA Mode: Printer: Relay Reset by User D6500 Mode: SIA Mode: Printer: Relay Reset by User (4-digit User) Relay Reset by Programmer (4-digit Relay) Relay Reset by Remote (4-digit Relay) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message 119 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Relay Reset by SKED (4-digit Relay) Printer: dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD20t
[#aaaa|NaikkkROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY RESET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD18t
[#aaaa|NidiiiiROrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrr SDI=ddd h1rrlssssssaaaasNsD21t
[#aaaa|NpidddRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrr h1rrlssssssaaaasNsD23t
[#aaaa|NRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrr SKED=kkk h1rrlssssssaaaasNsD19t
[#aaaa|NaikkkRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiiRCrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY PROGRAMMER +++ACC aaaa RELAY#=rrrr SDI=ddd h1rrlssssssaaaasNsD21t
[#aaaa|NpidddRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY REMOTE +++ACC aaaa RELAY#=rrrr h1rrlssssssaaaasNsD23t
[#aaaa|NRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY SKED +++ACC aaaa RELAY#=rrrr SKED=kkk h1rrlssssssaaaasNsD19t
[#aaaa|NaikkkRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RELAY SET +++ACC aaaa BY USER +++ACC aaaa ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD28t
[#aaaa|NidiiiiRCrrrr] dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=a POINT=ppp PH#=hh h1rrlssssssaaaasNspppt
[#aaaa|Nria/phhhUBppp] dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp PH#=hh h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/phhhUBpppp] Relay Reset by User (4-digit Relay) Relay Reset by User (4-digit User / Relay) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Relay Set by Programmer D6500 Mode: SIA Mode: Printer: Relay Set by Remote D6500 Mode: SIA Mode: Printer: Relay Set by SKED D6500 Mode: SIA Mode: Printer: Relay Set by User D6500 Mode: SIA Mode: Printer: Relay Set by User (4-digit User) Relay Set by Programmer (4-digit Relay) Relay Set by Remote (4-digit Relay) Relay Set by SKED (4-digit Relay) Relay Set by User (4-digit Relay) Relay Set by User (4-digit User / Relay) Remote Bypass / Callback Remote Bypass / Callback (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 120 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 473 474 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Remote Bypass Printer: dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa RAM BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa REMOTE RESET h1rrlssssssaaaasNsD11t
[#aaaa|NRN] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NBRppp] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaBRppp] dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaBHppp] dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NBHppp] dd/dd tt:tt Lxx ACC aaaa RESTORE FRM ALM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaBHpppp] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiUR] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiiUR] dd/dd tt:tt Lxx ACC aaaa RESTORAL REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaBRpppp] dd/dd tt:tt Lxx ACC aaaa RF INTERFERENCE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD08t
[#aaaa|NpidddXQ] dd/dd tt:tt Lxx ACC aaaa RF INTRFER-REST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsD08t
[#aaaa|NpidddXH] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPER +++ACC aaaa SDI=ddd h1rrlssssssaaaasXss35t
[#aaaa|NpidddXS] dd/dd tt:tt Lxx ACC aaaa RCVR TAMPR REST +++ACC aaaa SDI=ddd h1rrlssssssaaaasXss36t
[#aaaa|NpidddXJ] dd/dd tt:tt Lxx ACC aaaa RCVR TROUBLE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD17t
[#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa RCVR TBL RESTOR +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsD17t
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NXRppp] Remote Bypass (4-digit Point) 475 Remote Reset 476 Restoral (2112/2212) 477 478 479 480 481 482 483 484 485 486 487 488 489 490 Restoral (Trouble / Missing / Non-Fire Supervision) Restoral from Alarm Restoral from Alarm (No Area) Restoral from Alarm (4-digit Point) Restoral from Keyfob Restoral from Keyfob (4-digit User) Restoral (Trouble / Missing / Non-Fire Supervision) (4-digit Point) RF Interference RF Interference Restoral RF Receiver Tamper (2212) RF Receiver Tamper Restoral (2212) RF Receiver Trouble (2212) RF Receiver Trouble Restoral (2212) RF Transmitter Battery Restoral (2212) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 121 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation RF Transmitter Battery Restoral Printer: dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsD10t
[#aaaa|NpidddXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasRsD10t
[#aaaa|NidiiiiXR] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaXRppp] dd/dd tt:tt Lxx ACC aaaa RF BATT RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaXRpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NXTppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsD10t
[#aaaa|NpidddXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaXTppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iii h1rrlssssssaaaasTsD10t
[#aaaa|NidiiiXT] dd/dd tt:tt Lxx ACC aaaa RF BATTERY LOW +++ACC aaaa KEYFOB +++ACC aaaa ID=iiii h1rrlssssssaaaasTsD10t
[#aaaa|NidiiiiXT] dd/dd tt:tt Lxx ACC aaaa RF TAMPER ALARM +++ACC aaaa POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NTAppp] dd/dd tt:tt Lxx ACC aaaa RF TAMPER ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasAspppt
[#aaaa|NriaTAppp] dd/dd tt:tt Lxx ACC aaaa RF TAMPER ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaTApppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ACC aaaa POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NTRppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasRspppt
[#aaaa|NriaTRppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR RSTORAL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaTRpppp] RF Transmitter Battery Restoral from Keyfob RF Transmitter Battery Restoral from Keyfob (4-digit User) RF Transmitter Battery Restoral RF Transmitter Battery Restoral (4-digit Point) RF Transmitter Low Battery (2212) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: RF Transmitter Low Battery D6500 Mode: SIA Mode: Printer: RF Transmitter Low D6500 Mode: SIA Mode: Printer: RF Transmitter Low Battery (4-digit Point) RF Transmitter Low Battery from Keyfob RF Transmitter Low Battery from Keyfob (4-digit User) RF Transmitter Tamper Alarm (2212) RF Transmitter Tamper Alarm RF Transmitter Tamper Alarm (4-digit Point) RF Transmitter Tamper Restoral (2212) RF Transmitter Tamper Restoral RF Transmitter Tamper Restoral (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 122 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation RF Transmitter Tamper Trouble (2212) Printer: dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ACC aaaa POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NTTppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaTTppp] dd/dd tt:tt Lxx ACC aaaa RF TMPR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaTTpppp] dd/dd tt:tt Lxx ACC aaaa SDI FAILURE +++ACC aaaa GROUND FAULT +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa SDI FAILURE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa GROUND FAULT +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa SDI RESTORAL +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa DEVICE AC FAIL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEP] dd/dd tt:tt Lxx ACC aaaa DEV AC RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEQ] dd/dd tt:tt Lxx ACC aaaa DEVICE BAT TRBL +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEB] dd/dd tt:tt Lxx ACC aaaa DEVICE LOW BATT +++ACC aaaa BATT=bb SDI=dddd h1rrlssssssaaaasTsssDt
[#aaaa|NpiddddEBbb] dd/dd tt:tt Lxx ACC aaaa LOW BAT RESTORE +++ACC aaaa BATT=bb SDI=dddd h1rrlssssssaaaasRsssDt
[#aaaa|NpiddddEVbb] dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddEM] dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING +++ACC aaaa SDI=dddd h1rrlssssssaaaasTsssDt
[#aaaa|NpiddddEM] dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEN] dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST +++ACC aaaa SDI=dddd h1rrlssssssaaaasRsssDt
[#aaaa|NpiddddEN] dd/dd tt:tt Lxx ACC aaaa DEVICE MIS BATT +++ACC aaaa BATT=bb SDI=dddd h1rrlssssssaaaasTsssDt
[#aaaa|NpiddddEBbb] RF Transmitter Tamper Trouble RF Transmitter Tamper Trouble (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: SDI Bus Fail / Ground Fault D6500 Mode: SIA Mode: Printer: SDI Bus Fail D6500 Mode: SIA Mode: Printer: SDI Bus Restoral / Ground Fault D6500 Mode: SIA Mode: Printer: SDI Bus Restoral D6500 Mode: SIA Mode: Printer: SDI Device AC Failure D6500 Mode: SIA Mode: Printer: SDI Device AC Restoral D6500 Mode: SIA Mode: Printer: SDI Device Battery Trouble D6500 Mode: SIA Mode: Printer: SDI Device Low Battery (4-digit Device) SDI Device Low Battery Restore (4-digit Device) SDI Device Missing SDI Device Missing (4-digit Device) SDI Device Missing Restore SDI Device Missing Restore (4-digit Device) SDI Device Missing Battery (4-digit Device) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message New Message New Message New Message 123 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 124 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Comments SDI Device Missing Battery Reset (4-digit Device) Printer: dd/dd tt:tt Lxx ACC aaaa MISS BATT REST +++ACC aaaa BATT=bb SDI=dddd h1rrlssssssaaaasRsssDt
[#aaaa|NpiddddEVbb] dd/dd tt:tt Lxx ACC aaaa DEV BAT RESTORE +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddEV] dd/dd tt:tt Lxx ACC aaaa DEVICE MISSING +++ACC aaaa SDI=dddd h1rrlssssssaaaasTsssDt
[#aaaa|NpiddddEM] dd/dd tt:tt Lxx ACC aaaa DEV MISSING RST +++ACC aaaa SDI=dddd h1rrlssssssaaaasRsssDt
[#aaaa|NpiddddEN] dd/dd tt:tt Lxx ACC aaaa DEVICE TROUBLE +++ACC aaaa SDI=ddd h1rrlssssssaaaasTsssDt
[#aaaa|NpidddET] dd/dd tt:tt Lxx ACC aaaa DEV TROUBLE RST +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsssDt
[#aaaa|NpidddER] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiXIrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrrr h1rrlssssssaaaasNsD27t
[#aaaa|Nriaa/idiiiXIrrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=a ID=iiii RELAY#=rrrr h1rrlssssssaaaasNsD27t
[#aaaa|Nria/idiiiiXIrrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nriaa/idiiiXIrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESET +++ACC aaaa AREA=aa ID=iiii RELAY#=rrr h1rrlssssssaaaasNsD27t
[#aaaa|Nriaa/idiiiiXIrrr] dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaRQspppt
[#aaaa|NriaXNppp] dd/dd tt:tt Lxx ACC aaaa SENSOR RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRQppppt
[#aaaa|NriaaXNpppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasQspppt
[#aaaa|NriaXKppp] dd/dd tt:tt Lxx ACC aaaa SENSOR TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasQppppt
[#aaaa|NriaaXKpppp] dd/dd tt:tt Lxx ACC aaaa SERVICE BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa SERVICE RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaRBppppt
[#aaaa|NriaaUUpppp] dd/dd tt:tt Lxx ACC aaaa SERVICE END h1rrlssssssaaaasRsssFt
[#aaaa|NTE] New Message SDI Device Low Battery Restoral SDI Device Missing (4-digit Device) SDI Device Missing Restore (4-digit Device) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: SDI Device Trouble D6500 Mode: SIA Mode: Printer: SDI Device Trouble Restore D6500 Mode: SIA Mode: Printer: Sensor Reset D6500 Mode: SIA Mode: Printer: Sensor Reset (4-digit Relay) Sensor Reset (4-digit User / Device) Sensor Reset Sensor Reset (4-digit User) Sensor Restore Sensor Restore (4-digit Point) Sensor Trouble Sensor Trouble (4-digit Point) Service Bypass (4-digit Point) Service Bypass Restore (4-digit Point) Service End (2212) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 New Message New Message 4 New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 543 544 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Service End Printer: dd/dd tt:tt Lxx ACC aaaa SERVICE END +++ACC aaaa AREA=a h1rrlssssssaaaasRsssFt
[#aaaa|NriaTE] dd/dd tt:tt Lxx ACC aaaa SERVICE END +++ACC aaaa ID=iii h1rrlssssssaaaasRsssFt
[#aaaa|NidiiiTE] dd/dd tt:tt Lxx ACC aaaa SERVICE REQUEST h1rrlssssssaaaasNsD45t
[#aaaa|NYX] dd/dd tt:tt Lxx ACC aaaa SERVICE START h1rrlssssssaaaasTsssFt
[#aaaa|NTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt
[#aaaa|NriaTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|NidiiiTS] dd/dd tt:tt Lxx ACC aaaa SERVICE START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ACC aaaa AREA=a POINT=ppp SKED=kkk h1rrlssssssaaaasNspppt
[#aaaa|Nria/aikkkUBppp] dd/dd tt:tt Lxx ACC aaaa SKED BYPASS +++ACC aaaa AREA=aa POINT=pppp SKED=kkk h1rrlssssssaaaasNppppt
[#aaaa|Nriaa/aikkkUBpppp] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa SKED=kkk h1rrlssssssaaaasNsD06t
[#aaaa|NaikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa ID=iii SKED=kkk h1rrlssssssaaaasNsD06t
[#aaaa|Nidiii/aikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED CHANGED +++ACC aaaa ID=iiii SKED=kkk h1rrlssssssaaaasNsD06t
[#aaaa|Nidiiii/aikkkJS] dd/dd tt:tt Lxx ACC aaaa SKED EXECUTED +++ACC aaaa SKED=kkk h1rrlssssssaaaasNsD25t
[#aaaa|NaikkkJR] dd/dd tt:tt Lxx ACC aaaa S:ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSAspppt
[#aaaa|OriaBAppp] dd/dd tt:tt Lxx ACC aaaa S:ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaBApppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaASppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=a POINT=ppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaaSTspppt
[#aaaa|Oria/lvlll/vavvvASppp] Service End (No Area) D6500 Mode: SIA Mode: Printer: 545 Service Request 546 Service Start (2212) 547 Service Start by User D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Service Start D6500 Mode: SIA Mode: Printer: 548 549 550 551 552 553 554 555 556 557 558 559 560 Service Start (No Area) Service Start by User (4-digit User) SKED Bypass SKED Bypass (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: SKED Changed D6500 Mode: SIA Mode: Printer: SKED Changed by User D6500 Mode: SIA Mode: Printer: SKED Changed by User (4-digit User) D6500 Mode: SIA Mode: Printer: SKED Executed D6500 Mode: SIA Mode: Printer: Status: Alarm D6500 Mode: SIA Mode: Printer: Status: Alarm (4-digit Point) Status: Analog Service Status: Analog Service (Level & Value) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 125 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Status: Analog Service (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaASpppp] dd/dd tt:tt Lxx ACC aaaa S:ANALOG SERVCE +++ACC aaaa AREA=aa POINT=pppp +++ACC aaaa LEVEL=lll VALUE=vvv h1rrlssssssaaaaSTppppt
[#aaaa|Oriaa/lvlll/vavvvASpppp] dd/dd tt:tt Lxx ACC aaaa S:CLOSING +++ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaCL] dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSAspppt
[#aaaa|OriaDFppp] dd/dd tt:tt Lxx ACC aaaa S:DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaDFpppp] dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSIspppt
[#aaaa|OriaDNppp] dd/dd tt:tt Lxx ACC aaaa S:DR LEFT OPEN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSIppppt
[#aaaa|OriaaDNpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSFspppt
[#aaaa|OriaFAppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa CROSS POINT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] Status: Analog Service (Level & Value) (4-digit Point) D6500 Mode: SIA Mode: Printer: Status: Close by Area D6500 Mode: SIA Mode: Printer: Status: Door Forced D6500 Mode: SIA Mode: Printer: Status: Door Forced (4-digit Point) Status: Door Left Open Status: Door Left Open (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Status: Fire Alarm D6500 Mode: SIA Mode: Printer: Status: Fire Alarm / Cross Point D6500 Mode: SIA Mode: Printer: Status: Fire Alarm / Smoke Detector Status: Fire Alarm / High Temp Sensor Status: Fire Alarm / Waterflow Sensor Status: Fire Alarm (4-digit Point) Status: Fire Alarm / Cross Point (4-digit Point) Status: Fire Alarm / Smoke Detector (4-digit Point) Status: Fire Alarm / High Temp Sensor (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 126 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Status: Fire Alarm / Waterflow Sensor (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa S:FIRE ALARM +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSFppppt
[#aaaa|OriaaFApppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt
[#aaaa|OriaFYppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt
[#aaaa|OriaaFYpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt
[#aaaa|OriaFSppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt
[#aaaa|OriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSEspppt
[#aaaa|OriaFSppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE SUPRVISN +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSEppppt
[#aaaa|OriaaFSpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSGspppt
[#aaaa|OriaFTppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa SMOKE DETECTOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa HIGH TEMPERATURE SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:FIRE TROUBLE +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSGppppt
[#aaaa|OriaaFTpppp] dd/dd tt:tt Lxx ACC aaaa S:GAS ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|NriaaGApppp] Status: Fire Missing Status: Fire Missing (4-digit Point) Status: Fire Supervision Status: Fire Supervision (4-digit Point) Status: Fire Supervision / Waterflow Sensor Status: Fire Supervision / Waterflow Sensor (4-digit Point) Status: Fire Trouble Status: Fire Trouble / Smoke Detector Status: Fire Trouble / High Temp Sensror Status: Fire Trouble / Waterflow Sensor Status: Fire Trouble (4-digit Point) Status: Fire Trouble / Smoke Detector (4-digit Point) Status: Fire Trouble / High Temp Sensor (4-digit Point) Status: Fire Trouble / Waterflow Sensor (4-digit Point) Status: Gas Alarm (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message 127 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Comments Status: Gas Missing (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa S:GAS MISSING +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSVspppt
[#aaaa|NriaaUZppp] dd/dd tt:tt Lxx ACC aaaa S:GAS SUPV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSJspppt
[#aaaa|NriaaGSppp] dd/dd tt:tt Lxx ACC aaaa S:GAS TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|NriaaGTpppp] dd/dd tt:tt Lxx ACC aaaa S: HIGH-TEMP ALM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSJppppt
[#aaaa|NriaaKApppp] dd/dd tt:tt Lxx ACC aaaa S:HOLD-UP ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSDppppt
[#aaaa|NriaaHApppp] dd/dd tt:tt Lxx ACC aaaa S:HOLD-UP MISS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSVppppt
[#aaaa|NriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa S:HOLD-UP TRL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|NriaaHTpppp] dd/dd tt:tt Lxx ACC aaaa S:HOLD-UP TRL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|NriaaHTpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSZspppt
[#aaaa|OriaUZppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSZppppt
[#aaaa|OriaaUZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaFZppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaFZppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MIS FIR SUPRV +++ACC aaaa WATER FLOW SENSOR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaFZpppp] dd/dd tt:tt Lxx ACC aaaa S:MISS SUPRVISN +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSYspppt
[#aaaa|OriaBZppp] dd/dd tt:tt Lxx ACC aaaa S:MISS SUPRVISN +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSYppppt
[#aaaa|OriaaBZpppp] dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSVspppt
[#aaaa|OriaUYppp] New Message Status: Gas Supervisory (4-digit Point) Status: Gas Trouble (4-digit Point) Status: High Temp Alarm (4-digit Point) Status: Hold-Up Alarm (4-digit Point) Status: Hold-Up Missing (4-digit Point) Status: Hold-Up Supervisory Status: Hold-Up Trouble (4-digit Point) Status: Missing Alarm Status: Missing Alarm (4-digit Point) Status: Missing Fire Supervision Status: Missing Fire Supervision / Waterflow Sensor Status: Missing Fire Supervision (4-digit Point) Status: Missing Fire Supervision / Waterflow Sensor (4-digit Point) Status: Missing Supervision Status: Missing Supervision (4-digit Point) Status: Missing Trouble D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 128 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 New Message New Message New Message New Message New Message New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Status: Missing Trouble (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa S:MISSING TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSVppppt
[#aaaa|OriaaUYpppp] dd/dd tt:tt Lxx ACC aaaa S:OPENING +++ACC aaaa AREA=a h1rrlssssssaaaaSOsssst
[#aaaa|OriaOP] dd/dd tt:tt Lxx ACC aaaa S:PERIM DELAY +++ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaNL] dd/dd tt:tt Lxx ACC aaaa S:PERIM INSTANT +++ACC aaaa AREA=a h1rrlssssssaaaaSCsssst
[#aaaa|OriaNL] dd/dd tt:tt Lxx ACC aaaa S:RF BATTRY LOW +++ACC aaaa SDI=ddd h1rrlssssssaaaaSTsD10t
[#aaaa|OpidddXT] dd/dd tt:tt Lxx ACC aaaa S:RF BATTRY LOW +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaXTppp] dd/dd tt:tt Lxx ACC aaaa S:RF BATTRY LOW +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaXTpppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-ALARM +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSAspppt
[#aaaa|OriaTAppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSAppppt
[#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-TRBL +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaTAppp] dd/dd tt:tt Lxx ACC aaaa S:RF TMPR-TRBL +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaTApppp] dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaBSppp] dd/dd tt:tt Lxx ACC aaaa S:SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaaSTspppt
[#aaaa|OriaBTppp] dd/dd tt:tt Lxx ACC aaaa S:TROUBLE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSTppppt
[#aaaa|OriaaBTpppp] dd/dd tt:tt Lxx ACC aaaa S: Water Alarm +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaaSJppppt
[#aaaa|OriaaWApppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasJspppt
[#aaaa|NriaBSppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasJspppt
[#aaaa|NriaBSppp] Status: Open by Area D6500 Mode: SIA Mode: Printer: Status: Perimeter Delay by Area D6500 Mode: SIA Mode: Printer: Status: Perimeter Instant by Area Status: RF Transmitter Low Battery (Device Specific) Status: RF Transmitter Low Battery Status: RF Transmitter Low Battery (4-digit Point) Status: RF Transmitter Tamper Alarm Status: RF Transmitter Tamper Alarm (4-digit Point) Status: RF Transmitter Tamper Trouble Status: RF Transmitter Tamper Trouble (4-digit Point) Status: Supervision Status: Supervision (4-digit Point) Status: Trouble Status: Trouble (4-digit Point) Status: Water Alarm (4-digit Point) Supervision(Non-Fire) Supervision / Ground Fault (Non-Fire) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message 129 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 628 629 630 631 632 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Supervision (Non Fire) (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SUPERVISION +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|NriaaBSpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NriaUBppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ACC aaaa POINT=ppp h1rrlssssssaaaasNspppt
[#aaaa|NUBppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasNppppt
[#aaaa|NriaaUBpppp] dd/dd tt:tt Lxx ACC aaaa SWINGER BYPASS h1rrlssssssaaaasNsssst
[#aaaa|NUB] dd/dd tt:tt Lxx ACC aaaa TAMPER ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasAppppt
[#aaaa|NriaaTApppp] dd/dd tt:tt Lxx ACC aaaa TAMPER RESTORE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|NriaaTHpppp] dd/dd tt:tt Lxx ACC aaaa TEST FAILED +++ACC aaaa PATH=ppp COND=nnn h1rrlssssssaaaasTsD49t
[#aaaa|NpapppXXnnn] Supervision / Ground Fault (4-digit Point) Swinger Bypass Swinger Bypass (2112/2212) Swinger Bypass (4-digit Point) 633 Swinger Bypass (7112) 634 Tamper Alarm (4-digit Point) 635 636 Tamper Alarm Restore (4-digit Point) Test Failed D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 130 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 637 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Test-Off Normal Expanded Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssEt h1rrlssssssaaaaSBsssst h1rrlssssssaaaaSLsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSRsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSUsssst h1rrlssssssaaaaSDsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSMsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSEsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSGsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSXss35t
[#aaaa|NRY]
[#aaaa|OJL]
[#aaaa|OJO]
[#aaaa|OET]
[#aaaa|OLS]
[#aaaa|OET]
[#aaaa|ORA]
[#aaaa|OJA]
[#aaaa|OET]
[#aaaa|OYC]
[#aaaa|OIA]
[#aaaa|OAT]
[#aaaa|OYM]
[#aaaa|OYT]
[#aaaa|OYF]
[#aaaa|OLT]
[#aaaa|OXF]
[#aaaa|OXQ]
[#aaaa|OFS]
[#aaaa|OAS]
[#aaaa|OFT]
[#aaaa|OBT]
[#aaaa|OBT]
[#aaaa|ONT]
[#aaaa|OXS] D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments TEST-OFF NORMAL LOG THRESHOLD LOG OVERFLOW PT BUS TROUBLE PROG ACCESS OK RF RCVR TROUBLE BAD CALL TO RAM USER TAMPER SDI FAILURE COMM FAILURE EQUIPMENT FAIL AC FAILURE BATTERY MISSING BATTERY LOW PARMS BAD CKSUM PHONE FAIL EXTRA RF POINT RF INTERFERENCE FIRE SUPERVISION ANALOG SERVICE FIRE FAULT CTRL POINT FAULT CHK DEVICE FAULT NETWORK FAILURE RF RCVR TAMPER 131 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 638 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Test Report Expanded Printer: dd/dd tt:tt Lxx ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa +++ACC aaaa h1rrlssssssaaaasRsssEt h1rrlssssssaaaaSBsssst h1rrlssssssaaaaSLsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSRsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSUsssst h1rrlssssssaaaaSDsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSPsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSMsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSEsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSGsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSTsssst h1rrlssssssaaaaSXss35t
[#aaaa|NRP]
[#aaaa|OJL]
[#aaaa|OJO]
[#aaaa|OET]
[#aaaa|OLS]
[#aaaa|OET]
[#aaaa|ORA]
[#aaaa|OJA]
[#aaaa|OET]
[#aaaa|OYC]
[#aaaa|OIA]
[#aaaa|OAT]
[#aaaa|OYM]
[#aaaa|OYT]
[#aaaa|OYF]
[#aaaa|OLT]
[#aaaa|OXF]
[#aaaa|OXQ]
[#aaaa|OFS]
[#aaaa|OAS]
[#aaaa|OFT]
[#aaaa|OBT]
[#aaaa|OBT]
[#aaaa|ONT]
[#aaaa|OXS] D6500 Mode: SIA Mode: 132 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments TEST REPORT LOG THRESHOLD LOG OVERFLOW PT BUS TROUBLE PROG ACCESS OK RF RCVR TROUBLE BAD CALL TO RAM USER TAMPER SDI FAILURE COMM FAILURE EQUIPMENT FAIL AC FAILURE BATTERY MISSING BATTERY LOW PARMS BAD CKSUM PHONE FAIL EXTRA RF POINT RF INTERFERENCE FIRE SUPERVISION ANALOG SERVICE FIRE FAULT CTRL POINT FAULT CHK DEVICE FAULT NETWORK FAILURE RF RCVR TAMPER Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation 639 Test Report (Non-Expanded) 640 Test Report / Off Normal (Non-Expanded) 641 Time Changed by User Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa TEST REPORT h1rrlssssssaaaasRsssEt
[#aaaa|NRP] dd/dd tt:tt Lxx ACC aaaa TEST-OFF NORMAL h1rrlssssssaaaasRsssEt
[#aaaa|NRY] dd/dd tt:tt Lxx ACC aaaa TIME CHANGED +++ACC aaaa ID=iii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiJT] dd/dd tt:tt Lxx ACC aaaa TIME CHANGED h1rrlssssssaaaasNsD07t
[#aaaa|NJT] dd/dd tt:tt Lxx ACC aaaa TIME CHANGED +++ACC aaaa ID=iiii h1rrlssssssaaaasNsD07t
[#aaaa|NidiiiiJT] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaBTppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NBTppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaBTppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa GROUND FAULT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaBTpppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasTspppt
[#aaaa|NriaDJppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa DOOR FORCED +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaDJpppp] dd/dd tt:tt Lxx ACC aaaa TROUBLE REPORT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasTppppt
[#aaaa|NriaaBTpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaBGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaBGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaFGppp] dd/dd tt:tt Lxx ACC aaaa UNVERFIED EVENT +++ACC aaaa AREA=a CG=gg POINT=ppp h1rrlssssssaaaasKspppt
[#aaaa|NriaUGppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaBGpppp] 642 Time Changed 643 Time Changed by User (4-digit User) 644 645 646 647 648 649 650 651 652 653 654 655 656 Trouble Trouble (2112/2212) Trouble / Ground Fault Trouble / Ground Fault (4-digit Point) Trouble / Door Forced Trouble / Door Forced (4-digit Point) Trouble (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: Unverified Event / Burg D6500 Mode: SIA Mode: Printer: Unverified Event / Fire D6500 Mode: SIA Mode: Printer: Unverified Event / Burg D6500 Mode: SIA Mode: Printer: Unverified Event / Fire D6500 Mode: SIA Mode: Printer: Unverified Event D6500 Mode: SIA Mode: Printer: Unverified Event / Burg (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments 133 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 134 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Unverified Event / Fire (4-digit Point) Printer: dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaFGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-BURG +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaBGpppp] dd/dd tt:tt Lxx ACC aaaa UNVRFD EVT-FIRE +++ACC aaaa AREA=aa CG=gg POINT=pppp h1rrlssssssaaaasKppppt
[#aaaa|NriaaFGpppp] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss7t
[#aaaa|Nria/idiiiUA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss7t
[#aaaa|NriaUA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD7 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss7t
[#aaaa|Nriaa/idiiiiUA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasUsss9t
[#aaaa|Nria/idiiiPA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=a h1rrlssssssaaaasUsss9t
[#aaaa|NriaPA] dd/dd tt:tt Lxx ACC aaaa USER ALARM CMD9 +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasUsss9t
[#aaaa|Nriaa/idiiiiPA] dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD38t
[#aaaa|NidiiiJYccc] dd/dd tt:tt Lxx ACC aaaa USER CODE ADDED +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD38t
[#aaaa|NidiiiiJYcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD04t
[#aaaa|NidiiiJVccc] dd/dd tt:tt Lxx ACC aaaa USR CODE CHANGE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD04t
[#aaaa|NidiiiiJVcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD05t
[#aaaa|NidiiiJXccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc h1rrlssssssaaaasNsD05t
[#aaaa|NJXcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE DELETE +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD05t
[#aaaa|NidiiiiJXcccc] dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER +++ACC aaaa AREA=a h1rrlssssssaaaasNsD03t
[#aaaa|NriaJA] dd/dd tt:tt Lxx ACC aaaa USR CODE TAMPER h1rrlssssssaaaasNsD03t
[#aaaa|NJA] Unverified Event / Burg (4-digit Point) Unverified Event / Fire (4-digit Point) User Alarm 7 by User User Alarm 7 (No User) User Alarm 7 by User (4-digit User) User Alarm 9 by User User Alarm 9 (No User) User Alarm 9 by User (4-digit User) User Code Added by User User Code Added by User (4-digit User) User Code Changed by User User Code Changed by User (4-digit User) User Code Deleted by User User Code Deleted (4-digit User) User Code Deleted by User (4-digit User) User Code Tamper (5 attmpts in 5min) User Code Tamper (2112/2212) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . Table 98: 675 676 677 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation User Level Set by User Printer: User Level Set D6500 Mode: SIA Mode: Printer: dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ACC aaaa CODE ID=ccc ID=iii h1rrlssssssaaaasNsD40t
[#aaaa|NidiiiJZccc] dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ACC aaaa CODE ID=cccc h1rrlssssssaaaasNsD40t
[#aaaa|NJZcccc] dd/dd tt:tt Lxx ACC aaaa USER LEVEL SET +++ACC aaaa CODE ID=cccc ID=iiii h1rrlssssssaaaasNsD40t
[#aaaa|NidiiiiJZcccc] dd/dd tt:tt Lxx ACC aaaa PROG ACCESS OK h1rrlssssssaaaasRsF01t
[#aaaa|NLS] dd/dd tt:tt Lxx ACC aaaa PROG ACCESS OK +++ACC aaaa SDI=ddd h1rrlssssssaaaasRsF01t
[#aaaa|NpidddLS] dd/dd tt:tt Lxx ACC aaaa RAM ACCESS OK h1rrlssssssaaaasRsssFt
[#aaaa|NRS] User Level Set by User (4-digit User) 678 Valid Access 679 Valid Access (SDI Device / D5360) 680 Valid Remote Access (2112/2212) 681 Valid Remote Access / Callback 682 683 684 685 686 687 688 689 690 691 Walk Test End by User (Invisible Points) Walk Test End by User (Invisible Points) (4-digit User) Walk Test End (No User) Walk Test End by User Walk Test End by User (4-digit User) Walk Test Point Walk Test Point (4-digit Point) Walk Test Point / Fire Walk Test Point / Fire (4-digit Point) Walk Test Start by User D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Comments Printer: dd/dd tt:tt Lxx ACC aaaa D6500 Mode: SIA Mode: +++ACC aaaa h1rrlssssssaaaasRsssFt
[#aaaa|NphhhRS] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasRsssFt
[#aaaa|Nria/idiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa AREA=a h1rrlssssssaaaasRsssFt
[#aaaa|NriaTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasRsssFt
[#aaaa|Nria/idiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST END +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasRsssFt
[#aaaa|Nriaa/idiiiiTE] dd/dd tt:tt Lxx ACC aaaa WALK TEST PT +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasZspppt
[#aaaa|NriaBXppp] dd/dd tt:tt Lxx ACC aaaa WALK TEST PT +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt
[#aaaa|NriaaBXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TST PT-FIR +++ACC aaaa AREA=a POINT=ppp h1rrlssssssaaaasZspppt
[#aaaa|NriaFXppp] dd/dd tt:tt Lxx ACC aaaa WALK TST PT-FIR +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasZppppt
[#aaaa|NriaaFXpppp] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 RAM ACCESS OK PH#=hh 135 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 98: 692 693 694 695 Modem4/ModemIIIa² Messages Event Device/Mode Display/Explanation Walk Test Start by User (Invisible Points) Printer: dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=a ID=iii h1rrlssssssaaaasTsssFt
[#aaaa|Nria/idiiiTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa INVISIBLE POINTS +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=a h1rrlssssssaaaasTsssFt
[#aaaa|NriaTS] dd/dd tt:tt Lxx ACC aaaa WALK TEST START +++ACC aaaa AREA=aa ID=iiii h1rrlssssssaaaasTsssFt
[#aaaa|Nriaa/idiiiiTS] dd/dd tt:tt Lxx ACC aaaa WAS FORCE ARMED h1rrlssssssaaaasWsssst
[#aaaa|NCW] dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET h1rrlssssssaaaasNsD09t
[#aaaa|NYW] dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET +++ACC aaaa SDI=dddd +++ACC aaaa D9412GV4 V2.01 h1rrlssssssaaaasNsD09t
[#aaaa|NpiddddYW] dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET +++ACC aaaa SDI=ddd h1rrlssssssaaaasNsD09t
[#aaaa|NpidddYW] dd/dd tt:tt Lxx ACC aaaa WATCHDOG RESET +++ACC aaaa SDI=dddd +++ACC aaaa xxxxxxxx Vx.xx h1rrlssssssaaaasNsD09t
[#aaaa|NpidddYW] dd/dd tt:tt Lxx ACC aaaa WATER ALARM +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasJppppt
[#aaaa|Nriaa/WApppp] dd/dd tt:tt Lxx ACC aaaa WATER ALM REST +++ACC aaaa AREA=aa POINT=pppp h1rrlssssssaaaasRppppt
[#aaaa|Nriaa/WHpppp] Walk Test Start by User (Invisible Points) (4-digit User) Walk Test Start Walk Test Start by User (4-digit User) 696 Was Force Armed 697 Watchdog Reset 698 Watchdog Reset 699 700 701 702 Watchdog Reset (Device Specific) Watchdog Reset (4-digit Device) (Version text) Water Alarm (4-digit Point) Water Alarm Restore (4-digit Point) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 136 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Comments New Message New Message New Message New Message Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . ZONEX and Comex Translation 2 These items supply additional information related to Appendix C: Modem4/ModemIIIa Messages. Some of these numbered items are also referenced in the Comments section of Appendix C. 1. When Point User Flag is programmed to Yes in panel programming of panels that support this function, the zone and point information will be translated. The D6600/D6100 converts point data to ZONEX format and user IDs to Comex format. Table 99 shows the translation of point data and Table 100 shows the translation of User IDs. If Point User Flag is programmed to a No in the panel, then the zone and point information are sent as received. Table 99: Point to ZONEX Translation Point ZONEX 001-008 100-800 009-024 101-116 025-040 201-216 041-056 301-316 057-072 401-416 073-088 501-516 089-104 601-616 105-120 701-716 121-136 801-816 137-152 117-132 153-168 217-232 169-184 317-332 185-200 417-432 201-216 517-532 217-232 617-632 233-247 717-731 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 137 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa Table 100: User ID to Comex Translation ID COMEX 0 0 1-5 001-005 0-13 601-608 14-21 701-708 22-29 801-808 30-37 B01-B08 38-45 C01-C08 46-53 D01-D08 54-61 E01-E08 62-69 F01-F08 70-249 000 2. When the D7112 is transmitting a test report in Modem II format, the area number is sent to the automation system if the output format is in SIA communications mode. 3. When transmitted by a D7112, the identification number, if any, also prints. Refer to Forced Point in the D9112B Program Entry Guide (P/N: 74-06145-000-D). 4. For these events, the area denotes the location of the keypad used to initiate the event (see Sensor Reset). 5. BFSK Format: For the D9112, unless otherwise specified, the zone digit “z” uses the “BFSK Zone Code” as a base for a given point. This code is programmed in the control panel by point. The zone digit “i” indicates the most significant digit of the user ID. 138 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix C: Modem4/Modem IIIa . 6. For the D7112, unless otherwise specified, Table 101 is the basis for the zone digit “z” and ID translation; however, actual IDs only go up to 25. Table 101: Reported Zone/ID to Actual Point/ID Reported Zone/ID Actual Point/ID Example 1: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 Label RF Point dd/dd tt:tt ql ACC aaaa FIRE ALARM +++ ACC aaaa AREA=a RF POINT=ppp 7. This message reports from a D7112 RF point. The internal or external printer prints the label “RF POINT=” instead of “POINT=” in the second line (Example 2). Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 139 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix D: Network Messages Appendix D: Network Messages For networked accounts, Nxx appears instead of Lxx in the line number. Table 102: 1 2 3 4 5 6 7 Network Messages Event Device/Mode Display Alarm Panel Substitution Printer: dd/dd tt:tt Nxx ACC aaaa ALARM-PNL SUBST +++ ACC aaaa PATH=003 COND=007 h1rrlssssssaaaaAsD53t
[#aaaa|Npt003AA007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE LOW h1rrlssssssaaaasXss58t
[#aaaa|NSC0002] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 VOLTAGE RESTORE h1rrlssssssaaaasXss68t
[#aaaa|NSC0003] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT RESTORED h1rrlssssssaaaasXss91t
[#aaaa|NSC0010] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INPUT SHORTED h1rrlssssssaaaasXss89t
[#aaaa|NSC0008] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT DISABLED h1rrlssssssaaaasXss93t
[#aaaa|NSC0012] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 INTERCEPT ENABLED h1rrlssssssaaaasXss92t
[#aaaa|NSC0011] Change of Status (C900 Voltage Low) Change of Status (C900 Voltage Restore) Change of Status (C900 Input Restored) Change of Status (C900 Input Shorted) Change of Status (C900 Intercept Disabled) Change of Status (C900 Intercept Enabled) D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 8 9 10 11 12 13 Change of Status (C900 Output Activated) Change of Status (C900 Output Deactivated) Change of Status (C900 Input Open) Change of Status (C900 Reboot) Change of Status (C900 Switched to Fallback) Change of Status (C900 Switched to Intercept) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 140 dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT ACTIVATED h1rrlssssssaaaasXss85t
[#aaaa|NSC0006] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 OUTPUT DEACTIVATED h1rrlssssssaaaasXss94t
[#aaaa|NSC0007] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaaC900 INPUT OPEN H1rrlssssssaaaasXss90t
[#aaaa|NSC0009] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 REBOOT h1rrlssssssaaaasXss59t
[#aaaa|NSC0001] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO FALLBACK h1rrlssssssaaaasXss82t
[#aaaa|NSC0005] dd/dd tt:tt Nxx ACC aaaa STATUS CHANGED +++ aaaa C900 SWITCHED TO INTERCPT h1rrlssssssaaaasXss87t
[#aaaa|NSC0004] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix D: Network Messages . Table 102: 14 Network Messages Event Device/Mode Display C900 Command Sent (Activate Output) Printer: dd/dd tt:tt Nxx ACC aaaa +++ aaaa h1rrlssssssaaaasXss84t
[#aaaa|NCO0005] COMMAND SENT ACTIVATE OUTPUT dd/dd tt:tt Nxx ACC aaaa +++ aaaa h1rrlssssssaaaasXss86t
[#aaaa|NCO0006] COMMAND SENT DEACTIVATE OUTPUT D6500 Mode: SIA Mode: 15 C900 Command Sent (Deactivate Output) Printer: D6500 Mode: SIA Mode: 16 C900 Command Sent (Disable Intercept Mode) Printer: D6500 Mode: SIA Mode: 17 18 19 20 21 22 23 C900 Command Sent (Switch to Fallback Mode) C900 Command Sent (Switch to Intercept Mode) C900 Command Sent (Supervision Rate Changed) Communications Fail (Account Disabled by Attack) Communications Fail (Polling Lost) Communications Fail Restore (Polling Restore) Dialer Error (Dialing Error) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: 24 25 26 27 28 Dialer Error (Invalid Message) Dialer Error (Message Unknown) Dialer Error (No Acknowledgement Received) Dialer Error (Not Dialing) Dialer Error (No Response to Acknowledgement) Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: Printer: D6500 Mode: SIA Mode: dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa DISABLE INTERCEPT MODE h1rrlssssssaaaasXss83t
[#aaaa|NCO0004] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO FALLBACK MODE h1rrlssssssaaaasXss81t
[#aaaa|NCO0003] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SWITCH TO INTERCEPT MODE h1rrlssssssaaaasXss88t
[#aaaa|NCO0002] dd/dd tt:tt Nxx ACC aaaa COMMAND SENT +++ aaaa SUPERVISION RATE CHANGED h1rrlssssssaaaasXss66t
[#aaaa|NCO0001] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa ACCOUNT DISABLED BY ATTACK +++ ACC aaaa PATH=003 COND=008 h1rrlssssssaaaasTsB03t
[#aaaa|Npt003YC008] dd/dd tt:tt Nxx ACC aaaa COMM FAIL +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasTsB02t
[#aaaa|Npt003YC009] dd/dd tt:tt Nxx ACC aaaa COMM FAIL RESTR +++ ACC aaaa PATH=003 COND=009 h1rrlssssssaaaasNsB02t
[#aaaa|Npt003YK009] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa DIALING ERROR h1rrlssssssaaaasXss73t
[#aaaa|NYU0003] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa INVALID MESSAGE h1rrlssssssaaaasXss77t
[#aaaa|NYU0007] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa MESSAGE UNKNOWN h1rrlssssssaaaasXss76t
[#aaaa|NYU0006] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO ACKNOWLEDGMNT RECEIVED h1rrlssssssaaaasXss71t
[#aaaa|NYU0001] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NOT DIALING h1rrlssssssaaaasXss72t
[#aaaa|NYU0002] dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO ACK h1rrlssssssaaaasXss75t
[#aaaa|NYU0005] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 141 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix D: Network Messages Table 102: 29 Network Messages Event Device/Mode Display Dialer Error (No Response to Handshake) Printer: dd/dd tt:tt Nxx ACC aaaa DIALER ERROR +++ aaaa NO RESPONSE TO HANDSHAKE h1rrlssssssaaaasXss74t
[#aaaa|NYU0004] D6500 Mode: SIA Mode: 30 Miscellaneous Message (30 Min Since Fallback Command) Printer: D6500 Mode: SIA Mode: 142 dd/dd tt:tt Nxx ACC aaaa MESSAGE +++ aaaa 30 MIN SINCE FALLBACK CMD h1rrlssssssaaaasXss95t
[#aaaa|NMI0001] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Appendix E: Pulse Output Table 103 to Table 111 vary depending on the account number specified and the digit parameter programmed using the drop-down menus in Menu Item 3.1.7 Event 3/1 or 4/1 (Figure 27). The output of the receiver depends on the reporting digit. Use the settings in Figure 27 that can be changed by the user: Reporting digits 0 to 9 and A are alarms Reporting digit B is an opening Reporting digit C is a closing Reporting digit D is a cancel Reporting digit E is a restore Figure 27: D6200 Receiver Software Line Card Configuration Table 103: Pulse 3/1 Format # Event Account Number Reporting Digit Device/Mode Displays 1. ALARM 123 4 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 4 [10]1011sssssss123sAsss4[13] [10]602415[9]00030101[#s123|NBA4][13] 2. OPENING 123 B Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 OPENING [10]1011sssssss123sOssss[13] [10]AA4214[9]00040101[#s123|NOP][13] 3. CLOSING 123 C Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CLOSING [10]1011sssssss123sCssss[13] [10]F94B14[9]00050101[#s123|NCL][13] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 143 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 103: # Event Pulse 3/1 Format (Continued) Account Number Reporting Digit Device/Mode Displays 4. CANCEL 123 D Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CANCEL [10]1011sssssss123s\ssss[13] [10]FBCE14[9]00060101[#s123|NOC][13] 5. RESTORE 123 E Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 RESTORE [10]1011sssssss123sRssss[13] [10]FC2214[9]00070101[#s123|NUR][13] 6. TROUBLE 123 F Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 TROUBLE [10]1011sssssss123sTssss[13] [10]ACD414[9]00080101[#s123|NBT][13] Table 104: # Account Number Reporting Digit Device/Mode Displays 7. ALARM 123 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]720816[9]00090101[#s123|NBA45][13] 8. OPENING 123 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 OPENING ZN 5 [10]1011sssssss123sOsss5[13] [10]B0B115[9]00100101[#s123|NOP5][13] 9. CLOSING 123 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CLOSING ZN 5 [10]1011sssssss123sCsss5[13] [10]B62215[9]00110101[#s123|NCL5][13] 10. CANCEL 123 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CANCEL ZN 5 [10]1011sssssss123s\sss5[13] [10]15E115[9]00120101[#s123|NOC5][13] 11. RESTORE 123 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 RESTORE ZN 5 [10]1011sssssss123sRsss5[13] [10]98E715[9]00130101[#s123|NUR5][13] 12. TROUBLE 123 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 TROUBLE ZN 5 [10]1011sssssss123sTsss5[13] [10]1CB015[9]00140101[#s123|NBT5][13] 144 Event Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 1 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 105: # Pulse 3/1E Menu 3.1.3.12 3-1 Extended Format = 2 Event Account Number Reporting Digit Device/Mode Displays 13. ALARM 123 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]210D16[9]00450102[#s123|NBA45][13] 14. OPENING 123 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 OPENING ZN B5 [10]1011sssssss123sOssB5[13] [10]829516[9]00460102[#s123|NOPB5][13] 15. CLOSING 123 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CLOSING ZN C5 [10]1011sssssss123sCssC5[13] [10]2F8216[9]00470102[#s123|NCLC5][13] 16. CANCEL 123 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CANCEL ZN D5 [10]1011sssssss123s\ssD5[13] [10]EC1316[9]00480102[#s123|NOCD5][13] 17. RESTORE 123 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 RESTORE ZN E5 [10]1011sssssss123sRssE5[13] [10]2E4F16[9]00490102[#s123|NURE5][13] 18. TROUBLE 123 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 TROUBLE ZN F5 [10]1011sssssss123sTssF5[13] [10]C72516[9]00500102[#s123|NBTF5][13] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 145 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 106: # Account Number Reporting Digit Device/Mode Displays 19. ALARM 123 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 ALARM_ZN 45 [10]1011sssssss123sAss45[13] [10]446B16[9]00150101[#s123|NBA45][13] 20. OPENING 123 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 OPENING B5 [10]1011sssssss123sOssB5[13] [10]17F616[9]00160101[#s123|NOPB5][13] 21. CLOSING 123 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CLOSING B5 [10]1011sssssss123sCssC5[13] [10]BAE116[9]00170101[#s123|NCLC5][13] 22. CANCEL 123 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 CANCEL B5 [10]1011sssssss123s\ssD5[13] [10]797016[9]00180101[#s123|NOCD5][13] 23. RESTORE 123 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 RESTORE B5 [10]1011sssssss123sRssE5[13] [10]BB2C16[9]00190101[#s123|NURE5][13] 24. TROUBLE 123 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 123 TROUBLE B5 [10]1011sssssss123sTssF5[13] [10]EA3F16[9]00200101[#s123|NBTF5][13] 146 Event Pulse 3/2 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 107: # Event Pulse 4/1 Account Number Reporting Digit Device/Mode Displays 25. ALARM 1234 5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 5 [10]1011ssssss1234sAsss5[13] [10]97CE15[9]00210101[#1234|NBA5][13] 26. OPENING 1234 B Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 OPENING [10]1011ssssss1234sOssss[13] [10]020A14[9]00220101[#1234|NOP][13] 27. CLOSING 1234 C Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CLOSING [10]1011ssssss1234sCssss[13] [10]510314[9]00230101[#1234|NCL][13] 28. CANCEL 1234 D Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CANCEL [10]1011ssssss1234s\ssss[13] [10]908414[9]00240101[#1234|NOC][13] 29. RESTORE 1234 E Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 RESTORE [10]1011ssssss1234sRssss[13] [10]976814[9]00250101[#1234|NUR][13] 30. TROUBLE 1234 F Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 TROUBLE [10]1011ssssss1234sTssss[13] [10]C29B14[9]00260101[#1234|NBT][13] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 147 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 108: # Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 1 Event Account Number Reporting Digit Device/Mode Displays 31. ALARM 1234 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]418416[9]00270101[#1234|NBA45][13] 32. OPENING 1234 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 OPENING ZN 5 [10]1011ssssss1234sOsss5[13] [10]C5C215[9]00280101[#1234|NOP5][13] 33. CLOSING 1234 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CLOSING ZN 5 [10]1011ssssss1234sCsss5[13] [10]C35115[9]00290101[#1234|NCL5][13] 34. CANCEL 1234 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CANCEL ZN 5 [10]1011ssssss1234s\sss5[13] [10]3EE515[9]00300101[#1234|NOC5][13] 35. RESTORE 1234 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 RESTORE ZN 5 [10]1011ssssss1234sRsss5[13] [10]B3E315[9]00310101[#1234|NUR5][13] 36. TROUBLE 1234 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN 5 [10]1011ssssss1234sTsss5[13] [10]F6F615[9]00320101[#1234|NBT5][13] 148 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 109: # Pulse 4/1E Menu 3.1.3.3 4/1 Extended = 2 Event Account Number Reporting Digit Device/Mode Displays 37. ALARM 1234 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]599816[9]00510102[#1234|NBA45][13] 38. OPENING 1234 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 OPENING ZN B5 [10]1011ssssss1234sOssB5[13] [10]FA0016[9]00520102[#1234|NOPB5][13] 39. CLOSING 1234 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CLOSING ZN C5 [10]1011ssssss1234sCssC5[13] [10]571716[9]00530102[#1234|NCLC5][13] 40. CANCEL 1234 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CANCEL ZN D5 [10]1011ssssss1234s\ssD5[13] [10]F60416[9]00540102[#1234|NOCD5][13] 41. RESTORE 1234 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 RESTORE ZN E5 [10]1011ssssss1234sRssE5[13] [10]345816[9]00550102[#1234|NURE5][13] 42. TROUBLE 1234 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 TROUBLE ZN F5 [10]1011ssssss1234sTssF5[13] [10]FB2C16[9]00560102[#1234|NBTF5][13] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 149 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output Table 110: # Pulse 4/2 Event Account Number Reporting Digit Device/Mode Displays 43. ALARM 1234 45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 45 [10]1011ssssss1234sAss45[13] [10]220516[9]00330101[#1234|NBA45][13] 44. OPENING 1234 B5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 OPENING B5 [10]1011ssssss1234sOssB5[13] [10]708D16[9]00340101[#1234|NOPB5][13] 45. CLOSING 1234 C5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CLOSING C5 [10]1011ssssss1234sCssC5[13] [10]DD9A16[9]00350101[#1234|NCLC5][13] 46. CANCEL 1234 D5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CANCEL D5 [10]1011ssssss1234s\ssD5[13] [10]4DC816[9]00360101[#1234|NOCD5][13] 47. RESTORE 1234 E5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 RESTORE E5 [10]1011ssssss1234sRssE5[13] [10]8F9416[9]00370101[#1234|NURE5][13] 48. TROUBLE 1234 F5 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 TROUBLE F5 [10]1011ssssss1234sTssF5[13] [10]132316[9]00380101[#1234|NBTF5][13] 150 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix E: Pulse Output . Table 111: # Pulse 4/3 Event Account Number Reporting Digit Device/Mode Displays 49. ALARM 1234 456 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 ALARM_ZN 456 [10]1011ssssss1234sAs456[13] [10]D5C017[9]00390101[#1234|NBA456][13] 50. OPENING 1234 B45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 OPENING B45 [10]1011ssssss1234sOsB45[13] [10]114C17[9]00400101[#1234|NOPB45][13] 51. CLOSING 1234 C45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CLOSING C45 [10]1011ssssss1234sCsC45[13] [10]1FA117[9]00410101[#1234|NCLC45][13] 52. CANCEL 1234 D45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 CANCEL D45 [10]1011ssssss1234s\sD45[13] [10]E2B017[9]00420101[#1234|NOCD45][13] 53. RESTORE 1234 E45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 RESTORE E45 [10]1011ssssss1234sRsE45[13] [10]DB7217[9]00430101[#1234|NURE45][13] 54. TROUBLE 1234 F45 Printer: D6500 Mode: SIA Mode: DD/DD TT:TT L01 ACCT 1234 TROUBLE F45 [10]1011ssssss1234sTsF45[13] [10]CC4C17[9]00440101[#1234|NBTF45][13] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 151 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix F: Format ID(by Message Type)–D6600 only Appendix F: Format ID (by Message Type) – D6600 Only If D6600 Menu Item 2.5.17 equals 1, the following outputs apply. Generic Example D6500 Byte Description Table 112: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 h 9 r r l s s s s a a a a C C C C C C C Title Description 1 Header Character (h) Optional, check with the computer automation software for compatibility 2 Message Type 9 3-4 Receiver Number Receiver gateway number from 01 to 99 5 Line/Group Number Line number in the receiver gateway that sent the message 6-9 Spaces Six spaces 10-13 Account Number Account number, four digits 14-21 Channels Channels 1 to 8 22 Trailer Character Typically, this is HEX 14 Table 113: t Generic Byte Description # Generic Example C SIA Mode Description <9>[#aaaa|CCCCCCCC] Generic SIA Byte Description Title Description L Standard line feed character CRC Cyclical redundancy check number Message Type 9 sequence# The message sequence number, the valid sequence number range is 0001 to 9999 receiver# The receiver gateway that sent the message, valid digits are 01 to 99 line# (Line/Group #) The line number of the line in the receiver gateway that sent the message. Valid digits are 00 to 99. The receiver uses Line 0 (zero) for internal messages. account# The communicator's account number, four digits. CCCCCCCC Channel 1 to 8 The heavier outlined row in Table 112 and Table 113 indicates the meaning of the shaded digit in the D6500 Byte Description, SIA Mode Description Generic Examples, and Table 114. 152 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix F: Format ID(by Message Type)–D6600 only . Table 114 shows examples for each format that the receiver supports. If Menu Item 2.5.17 = 1, the following message type follows a specific format ID. If Menu Item 2.5.17 = 0, the output to automation follows the standard message type ID. Table 114: # Message Examples Communication Format Mode Message Acron Super Fast SIA: D6500: [10]146D18900120101[#123|45678912][13] [10]9011sssss12345678912[14] Ademco Contact-ID SIA: D6500: [10]6A721Ca00140101[#7401|18113003003][13] [10]a011s740118113003003[14] Ademco 4-1 Express SIA: D6500: [10]1FDC12b00150101[#1234|7][13] [10]b011ssssss1234sAsss7[14] Ademco 4-2 Express SIA: D6500: [10]9D2F13c00160101[#1234|55][13] [10]c011ssssss1234sAss55[14] Ademco High Speed/ Scancom 4-8-1 SIA: D6500: [10]C3651Cf00180101[#1234|5678s9123s4][13] [10]f011ss1234s5678s9123s4[14] 5-8-1 SIA: D6500: [10]69311Df00190101[#12345|6789s1234s5][13] [10]f011s12345s6789s1234s5[14] 6-8-1 SIA: D6500: [10]42CD1Ef00200101[#123456|7891s2345s6][13] [10]f011123456s7891s2345s6[14] ADT SIA SIA: D6500: Caller ID SIA: D6500: [10]257B1Ce00570101[#0000|&9569688558][13] [10]e011ssssss9569688558[14] CFSK SIA: D6500: [10]BDAE17i00270101[#123ABC|0108][13] [10]i011ssss123ABC0108ss[14] DSC/Sur-Gard 4-3 SIA: D6500: [10]99EA17d00170101[#1234|NBA567][13] [10]d011ssssss1234sAs567[14] DTMF 4-1 SIA: D6500: [10]02A215t00400101[#1234|NBA5][13] [10]t011ssssss1234sAsss5[14] DTMF 4-2 SIA: D6500: [10]40EC16u00410101[#1234|NBA56][13] [10]u011ssssss1234sAss56[14] FBI Super Fast SIA: D6500: [10]921C15F00470101[#1234|5678][13] [10]F011ssssss12345678ss[14] Internal Message SIA: D500: [10]5FB90EZ00090124[NLT][13] [10]Z010sssssssssssXss51[14] ITI SIA: D6500: [10]ABFB19I00490101[#MMTST|g090A31][13] [10]I011sssMvMTSTg090A31[14] Link Test SIA: D6500: [10]2D270B[9]00920100[][13] [10]1010sssssssssss@ssss[14] 3-1 SIA: D6500: [10]827316p00340101[#s123|NBA12][13] [10]p011sssssss123sAss12[14] 3-1E SIA: D6500: [10]16A815p00330101[#s706|NBA1][13] [10]p011sssssss706sAsss1[14] SIA: D6500: [10]C37A16q00350101[#s706|NBA61][13] [10]q011sssssss706sAss61[14] Pulse Pulse 3-2 [10]0BB619G00480101[#0308|Nid39OP2][13] [10]G011[#0308|Nid39OP2][14] Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 153 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix F: Format ID(by Message Type)–D6600 only Table 115: Message Examples (continued) Pulse 4-1 SIA: D6500: [10]608F15r00360101[#7066|NBA0][13] [10]r011ssssss7066sAsss0[14] 4-1E SIA: D6500: [10]5ACC16r00370101[#1234|NBA12][13] [10]r011ssssss1234sAss12[14] 4-2 SIA: D6500: [10]8A7F16s00380101[#7066|NBA02][13] [10]s011ssssss7066sAss02[14] 4-2E SIA: D6500: [10]185317s00390101[#1234|NBA566][13] [10]s011ssssss1234sAs566[14] Modem4/ModemIIIa² /ModemIId SIA: D6500: [10]8B9C1AA00440101[#1234|Nti1158LF][13] [10]A011ssssss1234s*ssss[14] Modem II SIA: D6500: [10]942B15B00450101[#1481|NUR2][13] [10]B011ssssss1481sRsss2[14] BFSK SIA: D6500: [10]FFF115C00460101[#s2B2|NBA3][13] [10]C011sssssss2B2sAsss3[14] Robofon SIA: D6500: [10]2D3B15j00280101[#123ABC|12][13] [10]j011ssss123ABC12ssss[14] 4-16-1 SIA: D6500: [10]D47C26g00210101[#1234|2222s2222s2222s2222s2][13] [10]g011ss1234s2222s2222s2222s2222s2[14] 5-16-1 SIA: D6500: [10]91FC27g00220101[#12345|2222s2222s2222s2222s2][13 ] [10]g011s12345s2222s2222s2222s2222s2[14] 6-16-1 SIA: D6500: [10]13EA28g00230101[#123456|2222s2222s2222s2222s2][1 3] [10]g011123456s2222s2222s2222s2222s2[14] 4-24-1 SIA: D6500: [10]091930h00240101[#1234|2222s2222s2222s2222s2222s 2222s2][13] [10]h011ss1234s2222s2222s2222s2222s2222s2222s2[14] 5-24-1 SIA: D6500: [10]D4ED31h00250101[#12345|2222s2222s2222s2222s2222 s2222s2][13] [10]h011s12345s2222s2222s2222s2222s2222s2222s2[14] 6-24-1 SIA: D6500: [10]B51132h00260101[#123452|2222s2222s2222s2222s222 2s2222s2][13] [10]h011123452s2222s2222s2222s2222s2222s2222s2[14] Seriee DTMF SIA: D6500: [10]61F619K00900101[#7080|*#000***][13] [10]K01113*7080*#000***[14] Seriee FSK SIA: D6500: [10]352815k00290101[#123AB|101][13] [10]k011ssssss123ABs1s01[14] Sescoa Super Speed SIA: D6500: [10]787215700110101[#0258|A56s][13] [10]7011ssssss0258sA56ss[14] SIA SIA: D6500: [10]86E416[9]00500101[#7080|NBA01][13] [10]S011[#7080|NBA01][14] Pulse Scancom Scancom 154 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix F: Format ID(by Message Type)–D6600 only . Table 116: Silent Knight Message Examples (continued) FSK 0 SIA: D6500: [10]3E6714E01040101[#4444|NOP][13] [10]E011ssssss4444sOssss[13] FSK80 SIA: D6500: [10]3E6714E01040101[#4444|NBA13][13] [10]E011ssssss4444sAss08[14] FSK1 SIA: D6500: [10]DC7115m00300101[#7654|sA01][13] [10]m011s7654"sA01[14] FSK2 SIA: D6500: [10]8AAC17m00310101[#123456|HA00][13] [10]m011s123456"HA00[14] SIA: D6500: [10]C2EB26n00320101[#000257|1090000000110000000][13 ] [10]n011s000257s1s090000000110000000[14] VFSK 42 SIA: D6500: [10]8EFA16v00430101[#1234|NBA98][13] [10]v011ssssss1234sAss98[14] VFSK 41 SIA: D6500: [10]802515v00420101[#1234|NBA9][13] [10]v011ssssss1234sAsss9[14] VONK SIA: D6500: [10]802515V00450101[#55|123456789ABCDEFG][13] [10]V01155123456789ABCDEFG [14] X-SIA SIA: D6500: [10]86E416[9]01430101[#1234|6011100*’THISISATEST’12][ 13] [10]S011[#1234|6011100*’THISISATEST’12][14] Silent Knight Telim Varitech FSK 41,Varitec h FSK 42 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 155 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix G: SIA Report Codes Appendix G: ADT SIA Report Codes Table 117: ADT SIA Report Codes Description ADT SIA System Event System Reset Reset Memory AC Fail AA AC Restore AH AC Fail 4 hour AT AC Fail 4 hour Restore AJ TELCO Line Trouble (Line 1 or Line 2) LT TELCO Line Trouble Restore (Line 1 or Line 2) LR Low Battery System YT Low Battery Restore YR Change Date Description ADT SIA Expansion Module Interactive Keypad Tamper IA Interactive Keypad Trouble – Supervision IT Interactive Keypad Restore IR Cardreader Alarm DA Cardreader Trouble DT Cardreader Restore DR Point Gateway Tamper Alarm EA Point Gateway Tamper – Supervision ET Point Gateway Restore ER Printer Tamper Alarm PA Printer Trouble – Supervision PT Printer Restore PR Description ADT SIA Downloading DLL Aborted RA Start DLL RB DLL Interrupted RI End DLL Altered RS DLL Comm Fail RT End DLL Not Altered RG 156 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix G: SIA Report Codes . Description ADT SIA Burglary BA Burg Alarm BA BA PT Bypass BB BA Restore BR BA Trouble BT BA PT Unbypass BU Description ADT SIA Open/Close BA Auto Close CA BA Auto Close with Bypass – within Group CB BA Trouble Closing (closed with burg during exit) CF BA Bypass Closing – within Group CG BA Closing CL BA Auto Open OA BA Irregular Opening OI BA Opening OP BA No Close – Sched close time expire OT BA Exit Fail, exit error (user) EF Description ADT SIA Fire Fire Alarm FA Fire Trouble FT Fire Restore FR Fire Alarm Silence Fire Point Bypass FB Fire Alarm Point Unbypass FU Supervisory Alarm SS Supervisory Trouble ST Supervisory Restore SR Supervisory Point Bypass SB Supervisory Unbypass SU Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 157 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix G: SIA Report Codes Description ADT SIA Panic Hold-Up Alarm HA Hold-Up Point Trouble (sensor trouble) HT Hold-Up Restore HR Hold-Up Point Bypass HB Hold-Up Point Unbypass HU Hostage Alarm (Duress) HH Hostage Restore HR Medical Alarm MA Medical Restore MR Description ADT SIA Scheduling BA Change Close Time Change Auto On Level Change Close Time Print Only Description ADT SIA Other Supervised Bell Alarm UA Supervised Bell Trouble UT Supervised Bell Restore UR Remote Power Supply Alarm UA Remote Power Supply Trouble UT Remote Power Supply Restore UR Keyswitch Alarm UA Keyswitch Trouble UT Keyswitch Restore UR Janitor Keyswitch Alarm UA Janitor Keyswitch Trouble UT Janitor Keyswitch Restore UR Janitor On Premises (user on premises) JI Janitor Off Premises (user on premises restore) JO ADT On Premises SI ADT Off Premises SO Tamper Alarm TA Tamper Restore TR VVS Bypass VB VVS Unbypass VU Keypad Active AC Audible Walk Test AT Change Code 158 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix G: SIA Report Codes . Description ADT SIA Change Early Open Change Holiday Change Latest Close (sent to CMC only if Closing sched is altered) CL Change Open Time, schedule change Change Time, time/date reset Description ADT SIA System Test Walk Test, walk test mode WT Bell Test BT Hold-Up Test Alarm (sent to printer) Hold-Up Test Restore (sent to printer) Start FA Test, fire test FM End FA Test, fire test restore FK Start BA Test BN End BA Test BK Start Supervision Test SM End Supervision Test SK Start Hold-Up Test HM End Hold-Up Test HK Long Print Short Print Supervisory Test Print, manual trigger test report ST Supervisory Test Restore ST Fire Test Alarm Print, fire test FA Fire Test Restore Print, fire test restore FR BA Point Test Print BT BA Point Test Restore Print BT Hold-Up Suspicion Print HS Keypad No Access NA Untyped Bypass UB Untyped Unbypass UU Tamper Bypass TB Tamper Unbypass TU BA Diagnostics BW FA Diagnostics FW Output Trouble UT Output Restore UR Point Trouble UT Point Alarm, general alarm UA Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 159 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix G: SIA Report Codes Description ADT SIA Point Restore, general alarm restore UR Untyped Diagnostics UW BA Weak Battery BL FA Weak Battery FL HA Weak Battery HL SA Weak Battery SL UA Weak Battery UL Description ADT SIA Access nd 2 Man 2 Person Keypad Lockout Cardreader Irregular Access DI Manual PB Access, remote arm/disarm opening MP Access Denied Code Known, access denied DK Access Denied Code Unknown, access denied DD Description ADT SIA Dialer Test Report Dialer Test Report RP1 Dialer Test Report with System Trouble RP5 160 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) . Appendix H: RB2000 Messages (D6600 Only) For lines that are grouped, Gxx appears instead of Lxx. Table 118: # 1. 2. 3. 4. 5. 6. 7. 8. 9. RB2000 Messages Event Device/ Mode Display Mains Power Failure SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 32 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 34 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B2 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B4 Battery Broken SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 33 RF Y Battery Empty SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 33 RF Y Battery Full SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7 HTS Battery Empty SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 37 HTS Battery Full SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B7 Sensor Battery SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 38 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 B8 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 41 Mains Power Return Technical Alarm Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 161 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) Table 118: # 10. 11. 12. 13. 14. 15. 16. 162 RB2000 Messages (continued) Event Device/ Mode Display Technical Alarm Confirmed SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C1 PRO 100 Transmitter SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 42 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C2 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 43 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C3 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 44 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C4 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 46 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C6 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 47 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C7 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 48 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C8 PRO 100 Pull Cord PRO 100 Situation Alarm Pull Switch Confirmation at Local Unit Hand Transmitter/ Button Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) . Table 118: # 17. 18. 19. 20. 21. 22. 23. 24. RB2000 Messages (continued) Event Device/ Mode Display Emergency Button SIA
[] SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 C9 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 49 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX C9 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 49 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY C9 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4A SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CA SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4B SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CB Fire Alarm from Ext Input X SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4B Intrusion SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4C SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CC SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C External Input X RF Y - Alarm Activity Monitor Fire Alarm Intrusion from Ext Input X Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 163 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) Table 118: # 25. 26. 27. 28. 29. 30. 31. 164 RB2000 Messages (continued) Event Device/ Mode Display Intrusion from RF X SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 01 XX 4C External Alarm Button SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4D SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CD SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 4E SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 CE SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 51 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D1 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 52 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D2 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 53 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D3 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 54 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D4 Protocol Error RF Y Error RF Y Maintenance RF Y Start RF Y Disassembly Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) . Table 118: # 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. RB2000 Messages (continued) Event Device/ Mode Display RF Y Test OK SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 55 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D5 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 56 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D6 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 57 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D7 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 58 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY D8 Outgoing Call HNZ SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 60 Resetting SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 61 Personal Sign In SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx+++ 0E 00 00 00 62 Personal Sign Out SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 63 Door Alarm SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 64 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 65 RF Y Test NOK RF Y Plug RF Y Test Bed Alarm Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 165 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) Table 118: # 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 166 RB2000 Messages (continued) Event Device/ Mode Display Medical Remind SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 66 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 67 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 68 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 69 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 71 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 78 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F1 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F8 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 72 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F2 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 73 Confirmation Call SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F3 Pager Call Activated SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 74 Message 1 Message 2 Message 3 Sign Out Sign In Service Call Repeated Call Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) . Table 118: # RB2000 Messages (continued) Event Device/ Mode Display 52. Full Duplex Communication SIA Printer 53. Test Call SIA
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 75
[] 54. 55. 56. 57. 58. RF Jamming RF Y No Alive Call for Assistance Registration Call Manual Test Call Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 79 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 F9 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7A SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FA SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY 7B SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 02 XY FB SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7C SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FC SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7D SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FD SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 7E SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 00 00 FE Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 167 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix H: RB2000 (D6600 Only) Table 118: # 59. RB2000 Messages (continued) Event Release Code XX XX Device/ Mode SIA Display
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 00 XX XX FF Error Message HNZ2001 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX 42 Error Ended HNZ2001 SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 0E 01 YY XX C2 Status: Mains Power Failure SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 32 Status: Battery Broken SIA Printer
[] MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 33 Status: Battery Empty SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 37 64. Status: Signed Out SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ A2 00 00 00 71 65. Remote Programming Request SIA
[] Printer MM/DD HH:MM Lxx RB2 ACCT xxxxxxxxxxxx +++ 10 00 xx yy 70 60. 61. 62. 63. 168 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Appendix I: SafeCom Messages (D6600 Only) In D6500 Mode, the line number sent to the computer is only one digit. Refer to Table 119. If Virtual Line is 00, it is disabled. The D6600 reports the actual D6600 line card number. Table 119: Line# Virtual Line Conversion Table Converted to Line# D6500 SIA 01 1 01 02 2 03 Converted to D6500 SIA 13 J 13 02 14 K 14 3 03 15 L 15 04 4 04 16 M 16 05 5 05 17 N 17 06 6 06 18 O 18 07 7 07 19 P 19 08 8 08 1A Q 1a 09 9 09 1B R 1b 0A A 0a 1C S 1c 0B B 0b 1D T 1d 0C C 0c 1E U 1e 0D D 0d 1F V 1f 0E E 0e 20 W 20 0F F 0f 21 X 21 10 G 10 22 Y 22 11 H 11 23 Y 22 12 I 12 FF Y 22 For D6500 Mode, any Virtual Line greater than or equal to 22 is reported as Y. For SIA Mode, any Virtual Line greater than or equal to 22 is reported as 22. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 169 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 120: SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display 1. System Startup 6500 SIA1 hprrl00000100t
[#0000|0100] Printer2 dd/dd tt:tt Sxx SYSTEM STARTUP 6500 SIA1 hprrl0aaa0100t
[#0aaa|0100] Printer2 dd/dd tt:tt Sxx aaa>restart 6500 SIA1 hprrl0aaa0103t
[#0aaa|0103] Printer2 dd/dd tt:tt Sxx aaa>BATTERY TROUBLE 6500 SIA1 hprrl0aaa0104t
[#0aaa|0104] Printer2 dd/dd tt:tt Sxx aaa battery restore 6500 SIA1 hprrl0aaa0103t
[#0aaa|0103] Printer2 dd/dd tt:tt Sxx aaa>AUX FAULT 6500 SIA1 hprrl0aaa0104t
[#0aaa|0104] Printer2 dd/dd tt:tt Sxx aaa aux restore 6500 SIA1 hprrl0aaa0105t
[#0aaa|0105] Printer2 dd/dd tt:tt Sxx aaa>AC TROUBLE 6500 SIA1 hprrl0aaa0106t
[#0aaa|0106] Printer2 dd/dd tt:tt Sxx aaa ac restore 6500 SIA1 hprrl0aaa0105t
[#0aaa|0105] Printer2 dd/dd tt:tt Sxx aaa>POWER TROUBLE 6500 SIA1 hprrl0aaa0106t
[#0aaa|0106] Printer2 dd/dd tt:tt Sxx aaa power restore 6500 SIA1 hprrl0aaa0110t
[#0aaa|0110] Printer2 dd/dd tt:tt Sxx aaa>REMOTE COM RESTORE 6500 SIA1 hprrl0aaa0111t
[#0aaa|0111] Printer2 dd/dd tt:tt Sxx aaa>RF TROUBLE 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 170 Radio Restart Battery Trouble Battery Restoral Aux. Fault Aux. Restoral AC Trouble AC Restoral External Power Fail External Power Restoral Remote Com Restore RF Trouble Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Notes on Auto Output Valid only for DP1000, PID-FE10 Valid only for DP1000, PID-FE10 SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 SC3100 PID-0330 or 0340, SC2104 PID-0430 or 0440 This indicates that the radio could not report a previous message (until just now). Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 120: SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display 13. RF Restore 6500 SIA1 hprrl0aaa0112t
[#0aaa|0112] Printer2 dd/dd tt:tt Sxx aaa rf restore 14. System RF Channel Busy 6500 SIA1 hprrl00000111t
[#0000|0111] Printer2 dd/dd tt:tt Sxx CHn>CHANNEL BUSY 6500 SIA1 hprrl00000112t
[#0000|0112] Printer2 dd/dd tt:tt Sxx CHn channel clear 6500 SIA1 hprrl0aaa0121t
[#0aaa|0121] Printer2 dd/dd tt:tt Sxx aaa>CHANNEL BUSY 6500 SIA1 hprrl0aaa0122t
[#0aaa|0122] Printer2 dd/dd tt:tt Sxx aaa channel clear 6500 SIA1 hprrl0aaa022000t
[#0aaa|022000] Printer2 dd/dd tt:tt Sxx aaa>DIALER ERROR e 15. 16. 17. 18. System RF Channel Clear Channel Busy Channel Clear Dialer Error Notes on Auto Output “e” is error code. See below for details: 0 1 2 3 19. 20. 21. 22. 23. Tamper Fault Tamper Restore Phone Line Fail Phone Line Restore Aux. Power Fail -unknown error -dialing error -handshake error -noise error 4 -unexpected disconnect 5 -validation error 6 -priority error 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>TAMPER FAULT 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Printer2 dd/dd tt:tt Sxx aaa tamper restore 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>TELCO TROUBLE 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Printer2 dd/dd tt:tt Sxx aaa telco restore 6500 SIA1 hprrl0aaa03200301t
[#0aaa|03200301] Printer2 dd/dd tt:tt Sxx aaa>AUX POWER TROUBLE Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Dialer error is reported to automation in a format similar to 3-1 event. Valid only for SC2104 Valid only for SC2104 Valid only for SC5000 171 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 120: SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display Notes on Auto Output 24. Aux. Power Restore 6500 SIA1 hprrl0aaa03200101t
[#0aaa|03200101] Valid only for SC5000 Printer2 dd/dd tt:tt Sxx aaa aux power restore 6500 SIA1 hprrl0aaa03200302t
[#0aaa|03200302] 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 172 Fire Panic Burglary Panic Silent/Medical Panic Operator Evacuation Bell Input Normal Input Open Input Short Input Bypass Input Unbypass Zone Restore Printer2 dd/dd tt:tt Sxx aaa>FIRE PANIC 6500 SIA1 hprrl0aaa03200303t
[#0aaa|03200303] Printer2 dd/dd tt:tt Sxx aaa>BURGLARY PANIC 6500 SIA1 hprrl0aaa03200304t
[#0aaa|03200304] Printer2 dd/dd tt:tt Sxx aaa>SILENT/MEDICAL PANIC 6500 SIA1 hprrl0aaa03200305t
[#0aaa|03200305] Printer2 dd/dd tt:tt Sxx aaa>OPERATOR EVACUATION 6500 SIA1 hprrl0aaa0320011it
[#0aaa|0320011i] Printer2 dd/dd tt:tt Sxx aaa normal: input i 6500 SIA1 hprrl0aaa0320021it
[#0aaa|0320021i] Printer2 dd/dd tt:tt Sxx aaa>OPENED: input i 6500 SIA1 hprrl0aaa0320031it
[#0aaa|0320031i] Printer2 dd/dd tt:tt Sxx aaa>SHORTED: input i 6500 SIA1 hprrl0aaa0320041it
[#0aaa|0320041i] Printer2 dd/dd tt:tt Sxx aaa bypass: input i 6500 SIA1 hprrl0aaa0320051it
[#0aaa|0320051i] Printer2 dd/dd tt:tt Sxx aaa unbypass: input i 6500 SIA1 hprrl0aaa0320011zt
[#0aaa|0320011z] Printer2 dd/dd tt:tt Sxx aaa restore: zone z Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 120: SafeCom Messages - Line Card or Account Signals # Event Device/ Mode Display Notes on Auto Output 35. Zone Trouble 6500 SIA1 hprrl0aaa0320021zt
[#0aaa|0320021z] Valid only for SC5000 36. 37. 38. 39. 40. 41. 42. 43. 44. 45. Fire Alarm Silent Alarm Burglary Alarm Zone Bypass Zone Unbypass Operator Armed User Armed Operator Disarmed User Disarmed User Duress 1 - Refer to Table 2 - Refer to Table Printer2 dd/dd tt:tt Sxx aaa>TROUBLE: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] Printer2 dd/dd tt:tt Sxx aaa>FIRE: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] Printer2 dd/dd tt:tt Sxx aaa>SILENT: zone z 6500 SIA1 hprrl0aaa0320031zt
[#0aaa|0320031z] Printer2 dd/dd tt:tt Sxx aaa>BURGLARY: zone z Valid only for SC5000, depending on the zone type 6500 SIA1 hprrl0aaa0320041zt
[#0aaa|0320041z] Valid only for SC5000 Printer2 dd/dd tt:tt Sxx aaa BYPASS: zone z 6500 SIA1 hprrl0aaa0320051zt
[#0aaa|0320051z] Printer2 dd/dd tt:tt Sxx aaa unbypass: zone z 6500 SIA1 hprrl0aaa03200600t
[#0aaa|03200600] Printer2 dd/dd tt:tt Sxx aaa OPERATOR ARMED 6500 SIA1 hprrl0aaa0320060ut
[#0aaa|0320060u] Printer2 dd/dd tt:tt Sxx aaa ARMED: user u 6500 SIA1 hprrl0aaa03200700t
[#0aaa|03200700] Printer2 dd/dd tt:tt Sxx aaa>OPERATOR DISARMED 6500 SIA1 hprrl0aaa0320070ut
[#0aaa|0320070u] Printer2 dd/dd tt:tt Sxx aaa>DISARMED: user u 6500 SIA1 hprrl0aaa0320080ut
[#0aaa|0320080u] Printer2 dd/dd tt:tt Sxx aaa>DURESS: user u 6500 SIA1 hprrl0aaa03200900t
[#0aaa|03200900] Printer2 dd/dd tt:tt Sxx aaa OPERATOR CANCEL 6500 SIA1 hprrl0aaa0320090ut
[#0aaa|0320090u] Printer2 dd/dd tt:tt Sxx aaa CANCEL: user u Valid only for SC5000, depending on the zone type Valid only for SC5000, depending on the zone type Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Valid only for SC5000 Explanation of Automation Output Items (within Message Body only). Explanation of Printer Output Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Items. 173 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 121: SafeCom Messages - Intercepted Control Panel Signals # Event Device/ Mode Display 1. 3-1 Unexpanded 6500 SIA1 hprrlaaaa0220e0t
[#aaaa|0220e0] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e XXXXXXXX 3-1 Expanded, 42, BFSK, or Ademco 4-2 Express 6500 SIA1 hprrlaaaa0220ezt
[#aaaa|0220ez] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) ez XXXXXXXX FBI SuperFast 6500 SIA1 hprrlaaaa0321ezzet
[#aaaa|0321ezze] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX 6500 SIA1 hprrlaaaa0620eeeeeeeet0t
[#aaaa|0620eeeeeeeet0] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) eeee eeee t 6500 SIA1 hprrlaaaa072018qeeeggccc0t
[#aaaa|072018qeeeggccc0] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) qeee gg czzz >>>>>>>>>>>>>>> aaa>qeeeTTTTTTTTXXXXXXXX 6500 SIA1 hprrlaaaa0f20ffeeeezzzzzz0000000000000000t
[#aaaa|0f20ffeeeezzzzzz0000000000000000] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) feezzz 6500 SIA1 hprrlaaaa03231ezzt
[#aaaa|03231ezz] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) ezz >>>>>>>>>>>>>>> aaa>XXXXXXXX Modem II - PID 0x72, Unexpanded, without Status Report 6500 SIA1 hprrlaaaa0322ez00t
[#aaaa|0322ez00] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>XXXXXXXX Modem II - PID 0x72, Unexpanded, with Status Report 6500 SIA1 hprrlaaaa0322ez00t
[#aaaa|0322ez00] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX Modem II - PID 0x72, Expanded, without Status Report 6500 SIA1 hprrlaaaa0322ezzzt
[#aaaa|0322ezxx] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX Modem II - PID 0x72, Unexpanded, without Status Report 6500 SIA1 hprrlaaaa0322ez00t
[#aaaa|0322ez00] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>XXXXXXXX Modem II - PID 0x72, Unexpanded, with Status Report 6500 SIA1 hprrlaaaa0322ez00t
[#aaaa|0322ez00] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e z00 >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Ademco 4-9 High Speed Ademco Contact ID SIA DCS Modem II - PID 0x50 Table 121: # 174 Event SafeCom Messages - Intercepted Control Panel Signals Device/ Mode Display Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . 13. 14. 15. 16. 17. Modem II - PID 0x72, Expanded, without Status Report 6500 SIA1 hprrlaaaa0322ezzzt
[#aaaa|0322ezxx] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX Modem II - PID 0x72, Expanded, with Status Report 6500 SIA1 hprrlaaaa0322ezzzt
[#aaaa|0322ezzz] Printer2 dd/dd tt:tt Sxx aaa>(aaaa) e zxx >>>>>>>>>>>>>>> aaa>STATUS:XXXXXXXX Modem II - PID 0xBB 6500 SIA1, hprrlaaaa0621aaeezzz000t
[#aaaa|0621aaeezzz000] Modem IIe/IIIa2 Modem IIe/IIIa2 with 4-Digit Zone 3 Printer2 dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX 6500 SIA1, hprrlaaaa0621aaeezzz000t
[#aaaa|0621aaeezzz000] 3 Printer2 dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzz >>>>>>>>>>>>>>> aaa>XXXXXXXX 6500 SIA1, hprrlaaaa0622aaeezzzz00t
[#aaaa|0622aaeezzzz00] 3 Printer2 1 2 3 - Refer to Table Refer to Table Refer to Table dd/dd tt:tt Sxx aaa>(aaaa) aa ee zzzz >>>>>>>>>>>>>>> aaa>XXXXXXXX Explanation of Automation Output Items (within Message Body only). Explanation of Printer Output Items. Supported Event Codes. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 175 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Table 122: Explanation of Automation Output Items (within Message Body only) Character Meaning aaa Radio account number (in hex), range: 001 to 9C4. i Input number, range: 1 to 8. z Zone number, range: 1 to 8. u User number, range: 1 to 8. aaaa Control panel account number. e ee eee eeee Event code. eeeeeeee Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only). t Type code. z zz zzz zzzz zzzzzz Zone (or contact) code. gg Group number. ff Function code. aa Area code. q Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only). ccc Hex contact or user code. Table 123: Explanation of Printer Output Items Character Meaning dd/dd Month and day (MM/DD). tt:tt Time of message receipt (HH:MM). S SafeCom xx Line card number, range: 01 to 08. n Radio channel number, range: 1 to 8. aaa Radio account number (in hex), range: 001 to 9C4. > If exists, the signal is in high priority. e Error code (for dialer error signals only), range: 0 to 6. i Input number, range: 1 to 8. z Zone number, range: 1 to 8. u User number, range: 1 to 8. (aaaa) Control panel account number. 176 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 124: Explanation of Printer Output Items (continued) Character Meaning e ee eee Event code. eeee eeee Event codes for Zone 1 thru 8 (Ademco 4-9 High Speed only). t Type code. z zz zzz Zone (or contact) code. gg Group number. f Function code. aa Area code. XXXXXXXX Translation text embedded (only when valid digital XLAT is selected for the radio account). TTTTTTTT Event type can be NEW, RESTORE, or PRIOR (Ademco Contact ID only). q Event qualifier (1: new event or opening, 3: restoral or closing, 6: previous message) (Ademco Contact ID only). Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 177 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) Modem IIe Format DD/MM HH:MM:SS NNN > (DDDD) AA EE ZZZ Modem IIe messages are reported as AA EE ZZZ where AA is the area code, EE is the event code from Table , and ZZZ is the zone or user code. For example: 01 EF 009 = area 1, alarm zone 9. Table 125: Supported Event Codes Code Meaning Code Meaning FE Listen in. D4 Walk test point. FD Fail to call RAM. D3 Extend close time by user ZZZ. FC Access granted. D2 Cancel by user ZZZ. FB Duress user ZZZ. D1 Status = open. FA User ZZZ alarm 7. D0 Open by user ZZZ. F9 User ZZZ alarm 9. CF Force close by user ZZZ. F8 Point ZZZ bypass. CE Status = closed. F7 Point ZZZ forced bypass. CD Close by user ZZZ. F6 Status = alarm ZZZ. CC Test report. F5 Status = trouble ZZZ. CB Log at threshold. F4 Fire alarm ZZZ. CA Log overflow. F3 Fire trouble ZZZ. C9 Parameter change. F2 Missing fire ZZZ. C8 User code tamper by user ZZZ. F1 Fire restore ZZZ. C7 User code for user ZZZ added or changed. F0 Fire trouble restore ZZZ. C6 Sked ZZZ execute. EF Alarm ZZZ. C5 Sked ZZZ changed. EE Trouble ZZZ. C4 Date changed by user ZZZ. ED Restore ZZZ. C3 Time changed by user ZZZ. EC Missing alarm ZZZ. C2 User level set by user ZZZ. EB Missing trouble ZZZ. C1 Valid programmer access by SDI device ZZZ. EA Point ZZZ open. C0 Invalid programmer access by SDI device ZZZ. E9 Point ZZZ close. BF Valid RAM access on phone ZZZ. E8 Extra point ZZZ. BE Invalid RAM access on phone ZZZ. E7 Point bus trouble. BD Comm fail phone ZZZ. E6 All points tested. BC Comm restore phone ZZZ. E5 Restoral from alarm. BB Phone line ZZZ fail. E4 Fire cancel. BA Phone line ZZZ restore. E3 User code added. B9 SDI device ZZZ trouble. E2 Service start. B8 SDI device ZZZ restore. E1 Service end. B7 Panel AC fail. E0 Sensor ZZZ reset. B6 Panel AC restore. DF Relay ZZZ set. B5 Panel battery missing. DE Relay ZZZ reset. B4 Panel battery low. DD Panel was forced armed. B3 Panel battery restore. DC Create status report. B2 Panel watchdog activated. DB Fire walk start by user ZZZ. B1 Supervision (non-fire) ZZZ. DA Fire walk end. B0 Remote reset. D9 Walk test start by user ZZZ. AF ROM checksum failure. D8 Walk test end. AE Memory failure. 178 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix I: SafeCom Messages (D6600 Only) . Table 125: Supported Event Codes (continued) Code Meaning Code Meaning D7 Fail to open. AD Reboot D6 Fail to close. AC Parameter checksum failure. D5 Area watch by user ZZZ. AB Force perimeter instant by user ZZZ. A6 Perimeter delayed by user ZZZ. 77 Status RF trans low battery point ZZZ. A5 Passcode for user ZZZ deleted. 76 Status RF trans tamper alarm point ZZZ. A4 Point bus restore. 75 Status RF trans tamper trouble point ZZZ. A2 Transmitter point ZZZ battery low. 74 Sensor Trouble point ZZZ. A1 Transmitter point ZZZ battery restore. 73 Sensor Trouble Restoral point ZZZ. A0 Transmitter point ZZZ tamper restore. 72 Status fire missing point ZZZ. 9F RF receiver trouble by SDI device ZZZ. 71 Status missing alarm point ZZZ. 9A Extra RF point ZZZ. 70 Status missing trouble point ZZZ. 99 RF receiver restore by SDI device ZZZ. 6F Status door forced point ZZZ. 98 RF interference by SDI device ZZZ. 6E Door locked point ZZZ. 95 Transmitter point ZZZ tamper alarm. 6D Missing fire supervision point ZZZ. 94 Transmitter point ZZZ tamper trouble. 6C Missing supervision point ZZZ. 92 Equipment restoral by SDI device ZZZ. 6B Status missing fire supervision point ZZZ. 91 Card assigned by user ZZZ. 6A Status missing supervision point ZZZ. 90 Card deleted by user ZZZ. 69 Status door left open point ZZZ. 8F Door cycled point ZZZ. 68 Failed to execute point ZZZ. 8E Door unlocked point ZZZ. 5F Analog service point ZZZ. 8D Door locked point ZZZ. 5E Analog restoral point ZZZ. 8C No entry point ZZZ. 5D Status analog service point ZZZ. 8B Door left open point ZZZ. 5C Test Failed path ZZZ. 8A Door request point ZZZ. 5B External device ZZZ. 89 Network failure path ZZZ. 5A Custom Function ZZZ Executed. 88 Network restoral path ZZZ. 59 Low Temperature point ZZZ. 87 Network condition path ZZZ. 58 Low Temperature Restoral point ZZZ. 86 Equipment fail by SDI device ZZZ. 56 Unverified Event point ZZZ. 85 Status supervision point ZZZ. 55 Printer Status by SDI device ZZZ. 84 Fire Supervision Restoral point ZZZ. 54 Abort by user ZZZ. 83 Fire supervision point ZZZ. 53 Service Request. 82 Fire Supervision Trouble point ZZZ. 52 Output ZZZ State. 81 Fire Supervision Trouble Restoral point ZZZ. 51 Output ZZZ State Restoral. 7F Status fire supervision point ZZZ. 50 Bypass Restoral point ZZZ. 7E Extra account path ZZZ. 4F Alarm Silenced point ZZZ. 7D Low signal strength path ZZZ. 4E Alarm-Panel Substitution path ZZZ. 7C RF receiver tamper by SDI device ZZZ. Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 179 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | J: Acknowledgement from Automation Software to D6600/D6100i Receiver Appendix J: Acknowledgement from Automation Software to D6600/D6100IPv6 Receiver If a response other than a valid ACK or NAK is received, the receiver will transmit the last message again. It will continue to send the same message until a valid NAK or ACK is received. 1. Automation software to receiver, ACK. The ACK from automation to receiver structure: D6500 mode: <0x06> 1 byte length and value is 0x06 SIA mode: [] LF Standard line feed character. CRC Cyclical Redundancy Check number. (Calculated the same as in SIA DC-07) TAB 09 hex Sequence# The message sequence number of the message which to be acknowledged. Receiver# The Receiver/Gateway number of the message to be acknowledged. Line#(Line/Group #) The line/group number of the message to be acknowledged. CR SIA trailer char, hex 0D 2. Automation software to receiver, NAK. A NAK response from automation software will force the receiver to transmit the last message again. If 3 sequential NAKs are received for the same message, then the receiver will skip that message and move to the next one. The NAK from automation to receiver structure: D6500 mode: <0x15> 1 byte length and value is 0x15 SIA mode: <0000><00>[] 180 LF Standard line feed character. CRC Cyclical Redundancy Check number. (Calculated the same as in SIA DC-07) TAB 09 hex 0000 The message sequence number, fixed 0000 for NAK. Receiver# The Receiver/Gateway that receives the NAK message, valid digits are: 01-99 for D6600. 00 The line number, fixed 00 for NAK. CR SIA trailer char, hex 0D Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix K SafeCom Messages (D6600 Only) . Appendix K: Cyclic Redundancy Check (CRC) Calculation This CRC calculation section is referenced from the SIA DC-07 Computer Interface Standard. The calculations for CRCs to the Bosch receivers are performed in the same manner. CRCs are based on treating bit strings as representations of polynomials with coefficients of 0 and 1 only. An n-bit message is regarded as the coefficient list for a polynomial with n terms, ranging from x ^ n-1 (high order bit) to x ^ 0 (low order bit). For example, 110001 has 6 bits and thus represents a six term polynomial with coefficients 1, 1, 0, 0, 0, and 1: x ^ 5 + x ^ 4 + x ^ 0. When the polynomial code method is employed, the sender and receiver must agree upon a generator polynomial in advance. Both the high order and low order bits of the generator must be 1. The basic idea is that the polynomial represented by the check summed message is divided by the generator. If there is a remainder, then there has been a transmission error. A 16 bit generator polynomial which has been widely implemented in data transfer protocols (such as XMODEM CRC) is: X ^ 16 + X ^ 15 + X ^ 2 + 1 This polynomial is called CRC-16. It catches all single and double errors, all errors with an odd number of bits, all burst errors of 16 bits or less, 99.997% (1/32768 chance of failure) of 17 bit burst errors, and 99.998% of 18 bit and longer burst errors (1/65536 chance of failure). Polynomial arithmetic is done modulo 2, according to the rules of algebraic field theory, and therefore should be performed with simple exclusive-ORs. Floating point is not required. Calculation Routines Two calculation routines are shown below, which each yield the same results. The second method of CRC calculation greatly speeds CRC processing, but does require a 512 byte table. Calculation Method 1 The following C Language program illustrates CRC calculation. It can be compiled as shown with many compilers to demonstrate the CRC process. /* THESE INCLUDES FOR MICROSOFT C 5.1 */ #include "stdio.h" #include "stdlib.h" /* FORWARDS */ unsigned int calcCRC(unsigned CRC, int ch); void main(void) { unsigned int CRC; int count, ch; char *ptr, str[1024]; /* 16 BIT CRC RESULT */ Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 181 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix K: Cyclic Redundancy Check (CRC) Calculation CRC = 0; count = 0; printf("Input string for CRC calculation ( to end): "); ptr = gets(str); while (ch = *ptr++) { CRC = calcCRC(CRC, ch); /* CALL CRC FUNCTION BELOW */ printf("\nChar %c [%2.2x] CRC is %4.4x, %2.2x count", (ch > 32) ? ch : '.', ch, CRC, ++count); } } unsigned int calcCRC(unsigned CRC, int ch) { int i; unsigned char temp; temp = (unsigned char)ch; /* TREAT LOCALLY AS UNSIGNED */ for (i = 0; i < 8; i++) /* DO 8 BITS */ { temp ^= CRC & 1; /* PROCESS LSB */ CRC >>= 1; /* SHIFT RIGHT */ if (temp & 1) CRC ^= 0xA001; /* IF LSB SET,ADD FEEDBACK */ temp >>= 1; /* GO TO NEXT BIT */ } return CRC; } Calculation Method 2 Alternatively, the routine calcCRC could be replaced by the following, faster routine: void calcCRC2(unsigned int CRC, int ch) { static unsigned int crcTable[]= { /* DEFINE THE FIRST ORDER POLINOMIAL TABLE */ 0x0000,0xc0c1,0xc181,0x0140,0xc301,0x03c0,0x0280,0xc241, 0xc601,0x06c0,0x0780,0xc741,0x0500,0xc5c1,0xc481,0x0440, 0xcc01,0x0cc0,0x0d80,0xcd41,0x0f00,0xcfc1,0xce81,0x0e40, 0x0a00,0xcac1,0xcb81,0x0b40,0xc901,0x09c0,0x0880,0xc841, 0xd801,0x18c0,0x1980,0xd941,0x1b00,0xdbc1,0xda81,0x1a40, 0x1e00,0xdec1,0xdf81,0x1f40,0xdd01,0x1dc0,0x1c80,0xdc41, 0x1400,0xd4c1,0xd581,0x1540,0xd701,0x17c0,0x1680,0xd641, 0xd201,0x12c0,0x1380,0xd341,0x1100,0xd1c1,0xd081,0x1040, 0xf001,0x30c0,0x3180,0xf141,0x3300,0xf3c1,0xf281,0x3240, 0x3600,0xf6c1,0xf781,0x3740,0xf501,0x35c0,0x3480,0xf441, 0x3c00,0xfcc1,0xfd81,0x3d40,0xff01,0x3fc0,0x3e80,0xfe41, 0xfa01,0x3ac0,0x3b80,0xfb41,0x3900,0xf9c1,0xf881,0x3840, 0x2800,0xe8c1,0xe981,0x2940,0xbe01,0x2bc0,0x2a80,0xea41, 0xee01,0x2ec0,0x2f80,0xef41,0x2d00,0xedc1,0xec81,0x2c40, 0xe401,0x24c0,0x2580,0xe541,0x2700,0xe7c1,0xe681,0x2640, 0x2200,0xe2c1,0xe381,0x2340,0xe101,0x21c0,0x2080,0xe041, 182 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix K SafeCom Messages (D6600 Only) . 0xa001,0x60c0,0x6180,0xa141,0x6300,0xa3c1,0xa281,0x6240, 0x6600,0xa6c1,0xa781,0x6740,0xa501,0x65c0,0x6480,0xa441, 0x6c00,0xacc1,0xad81,0x6d40,0xaf01,0x6fc0,0x6e80,0xae41, 0xaa01,0x6ac0,0x6b80,0xab41,0x6900,0xa9c1,0xa881,0x6840, 0x7800,0xb8c1,0xb981,0x7940,0xbb01,0x7bc0,0x7a80,0xba41, 0xbe01,0x7ec0,0x7f80,0xbf41,0x7d00,0xbdc1,0xbc81,0x7c40, 0xb401,0x74c0,0x7580,0xb541,0x7700,0xb7c1,0xb681,0x7640, 0x7200,0xb2c1,0xb381,0x7340,0xb101,0x71c0,0x7080,0xb041, 0x5000,0x90c1,0x9181,0x5140,0x9301,0x53c0,0x5280,0x9241, 0x9601,0x56c0,0x5780,0x9741,0x5500,0x95c1,0x9481,0x5440, 0x9c01,0x5cc0,0x5d80,0x9d41,0x5f00,0x9fc1,0x9e81,0x5e40, 0x5a00,0x9ac1,0x9b81,0x5b40,0x9901,0x59c0,0x5880,0x9841, 0x8801,0x48c0,0x4980,0x8941,0x4b00,0x8bc1,0x8a81,0x4a40, 0x4e00,0x8ec1,0x8f81,0x4f40,0x8d01,0x4dc0,0x4c80,0x8c41, 0x4400,0x84c1,0x8581,0x4540,0x8701,0x47c0,0x4680,0x8641, 0x8201,0x42c0,0x4380,0x8341,0x4100,0x81c1,0x8081,0x4040, }; unsigned char temp; temp = (unsigned char)ch; return (CRC >> 8) ^ (crcTable[temp ^ (CRC & 0xff)]); Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 183 Conettix D6600/D6100IPv6/D6100i | Computer Interface Manual | Appendix K: Cyclic Redundancy Check (CRC) Calculation Appendix L: Network Automation Overview Network automation is a function of the receiver that allows the receiver to send the information from the receiver to the automation software using a network connection instead of a RS-232 serial connection to COM3 on the receivers. The receivers only support one method of automation connection, either RS-232 serial on COM3 or network automation using Conettix IP connection on a D6600 or D6100IPv6. One method is not a fail over for the other. Network automation works by programming the receiver to send the events using the D6686/D6682/D6680 on COM4 of a D6600 or the on-board IP of the D6100IPv6/D6100i. Automation must be able to receive these events using UDP/IP over the network and able to send the ACK or NAK back to the receiver. Verify if the automation vendor is compatible with the Bosch network automation configuration. Automation Information The Bosch receivers send events over the network using UDP/IP to the IP Address of the PC that the automation software is running on and the port # that the automation is listening for the receiver on. Each receiver should be sending to a unique port # on the automation PC. The automation will receive each packet and must cache the source IP address and source port # to be used for the ACK or NAK packet creation. The automation will extract the data portion of the UDP packet and process the data to create an ACK or NAK as it normally would. The data portion of the IP packets is identical to the data that is sent over RS-232 serial to automation. Automation should process the data in the exact same manner as it would when received over serial. The automation shall reply to the receiver with the proper ACK or NAK in the data portion of a UDP packet using the cached source IP Address and port # as the destination IP Address and port #. Here is an example of this process: • Link Test from receiver to automation example o Link Test packet is sent from receiver IP Address 192.168.1.10 Port # 7700 to automation on IP Address 192.168.1.200 Port #10000.  Source IP Address 192.168.1.10  Source Port # 7700  Destination IP Address 192.168.1.200  Destination Port # 10000 o Automation accepts the packet, caches the source IP Address and Port # o Processes the data portion of the packet and generates the ACK/NAK for the data portion of the reply packet. o ACK/NAK reply packet is sent from automation IP Address 192.168.1.200 Port #10000 to receiver IP Address 192.168.1.10 Port #7700.  Source IP Address 192.168.1.200  Source Port 10000  Destination IP Address 192.168.1.10  Destination Port # 7700 See the Conettix D6600/D6100IPv6 Program Entry Guide – 4998122702 for detailed information on configuring the receiver to send using network automation in parameters 6.3 Network Automation Connection. 184 Bosch Security Systems, Inc. | 2012.09 | 4998122703-05 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY, 14450 USA www.boschsecurity.com © Bosch Security Systems, Inc., 2012

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Denise Delaney
Category                        : Affects
Comments                        : 4998122703-05
Company                         : Bosch Group
Create Date                     : 2012:12:14 11:39:16-05:00
Keywords                        : Receiver/Gateway
Modify Date                     : 2012:12:14 11:40:28-05:00
Source Modified                 : D:20121214163755
Subject                         : Computer Interface Manual
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2012:12:14 11:40:28-05:00
Creator Tool                    : Acrobat PDFMaker 10.1 for Word
Document ID                     : uuid:80fc2d0b-b48c-4e9a-8546-829f78529cfc
Instance ID                     : uuid:881dc2f1-230c-412c-a0ea-ce26c1546bb9
Format                          : application/pdf
Title                           : Conettix D6600/D6100IPv6/D6100i
Description                     : Computer Interface Manual
Creator                         : Denise Delaney
Producer                        : Adobe PDF Library 10.0
Headline                        : Computer Interface Manual
Page Layout                     : OneColumn
Page Count                      : 185
EXIF Metadata provided by
EXIF.tools

Navigation menu