Ceiling Mount PIR Detector with Self-Test DS938Z en Installation Guide Bosch Security Systems, Inc. product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems, Inc web site at: http://www.boschsecurity.com/datecodes/. © 2013 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 -29°C to +50°C (-20°F to +120°F ) UL Listed installations, the temperature range is 0°C to +50°C (+32°F to +120°F) 0 - 95% Relative Humidity (0 - 85% UL Installations) Changes or modifications not expressly approved by Bosch Security Systems, Inc. can void the user’s authority to operate the equipment. EN 50131-2-2 Grade 2 EN 50130-5 Environmental Class II IP30 IK04 (EN 60529, EN 62262) UL Perform Walk Test at least once a year. Use only a Listed limited-power source. The Listed control unit or a Listed burglary power supply must provide 4 hours (20 mAh) of standby power. Install the unit in accordance with National Electrical Code NFPA 70. Adjust the microwave range control, if necessary, to achieve maximum range. Certificat NF A2P 2620001760A1 2 boucliers NF324 - H58 Autosurveillance à l’ouverture Immunité champ magnétique Test sans masque de vision verticale et sans immunité aux animaux www.afnor.org www.cnpp.com 7.2 Selecting the Optical Module 1. For ceilings between 8 and 13 ft. (2.4 and 4.0 m) from the floor, use the optical module marked AR8-13. This marking can be found next to the two optical module tabs. 2. For ceilings between 13 and 18 ft. (4.0 and 5.5 m) high, use the optical module marked AR13-18. 3. To replace an optical module, push the optical module tabs towards the center until the module snaps free of the circuit board. Holding the new module by the tabs, snap the new module into place. NOTICE! When replacing the mirror, make sure it is facing the same direction as before it was removed. 4. Replace the enclosure onto the base. 5. Close cover and turn clockwise to secure. SELV Connect all wiring to a safety extra-low voltage (SELV) circuit only. Ligue todas as cablagens apenas a um circuito de segurança de tensão extra baixa (SELV). NOTICE! Avoid fingerprints on the mirrored surfaces. Should the mirrored surfaces become soiled or otherwise marked, they can be cleaned using a soft, clean cloth and any commonly available, mild window cleaner. Conecte el cableado únicamente a un circuito de seguridad para voltajes muy bajos (SELV). Alle Drähte sind ohne Ausnahme an Niederspannung anzuschließen. Sluit alle bedrading uitsluitend aan op een circuit met een extra lage veiligheidsspanning. Prenez soin de connecter tous les câbles à un circuit à très basse tension de sécurité (TBTS). AR8-13 Certification Europe CE AFNOR 1 2 3 4 5 4 3 2 1 4 3 EN50131-2-2, Grade 2 EN50130-5 Environmental Class II BASEBOARD 2 1 5 1 2 3 HEAT AR8-13 Region BASEBOARD HEAT Collegare tutti i cavi esclusivamente a un circuito SELV (circuito di sicurezza a bassissima tensione). MASK 3 SECTORS 2620001760A1 TECHOM 98/07 Klasy "C" USA UL ANSR: Intrusion Detection Units (UL639) Sweden INTYG 1 4 1 5 1 2 2 3 4 5 4 3 2 1 3 WINDOW MASK 15 SECTORS 04-683 AR8-13 Poland WINDOW AR8-13 Figure 7.2: Masking Trademark names are used throughout this document. In most cases, these designations are claimed as trademarks or registered trademarks in one or more countries by their respective owners. Rather than placing a trademark symbol in every occurrence of a trademark name, Bosch Security Systems, Inc. (hereinafter referred to as Bosch) uses the names only in an editorial fashion and to the benefit of the trademark owner with no intention of infringing the trademark. 2 © 2013 Bosch Security Systems, Inc. 8 Coverage • 360° by 60 ft. (18.3 m) diameter coverage when mounted on 8 to 18 ft (2.4 to 5.5 m) high ceilings. • The coverage pattern consists of 64 zones grouped into 16 barriers, with one additional zone looking straight down from the unit (sabotage). Each barrier is 30 ft (9.2 m) long and 4.4 ft. (1.3 m) wide at 30 ft (9.2 m). • The DS9382 comes with a choice of two optical modules. Refer to Section 5.1 to determine the best module for on ceiling height. F.01U.263.663 | 04 | 2013.04 | 11 If the time period selected has elapsed from the last alarm, the LED will flash two times and the Trouble Output will activate. 1 Overview Setting the Motion Monitor timer to shorter periods can be used to force a protection walk test of remotely located zones. It is recommended that the 30 day timer be selected. This verifies that the unit is operational and avoids nuisance trouble conditions caused by holidays, vacations, etc. The DS938Z is a high performance passive infrared intrusion detector. It is equipped with advanced PIR detection and supervision circuits and is designed to provide an alarm condition upon detection of an intruder passing through its area of coverage. Employing balanced dual-opposed sensing elements, the DS938Z passive infrared (PIR) detector makes use of the fact that all objects give off (emit) infrared energy, and that the warmer an object is, the greater the amount of infrared energy given off. The DS938Z uses PIR receiver technology designed to detect the change in infrared energy caused when a target of a different temperature from a stable background passes through its field of coverage. 7 Optical Module 7.1 Optical Module Masking Peel-off masks are provided with the unit for each segment of the optical module to allow for customized coverage, or to block out areas of objects that may cause thermal disturbances. The mask is selfadhesive and pre-cut in the shape of the optical module. The location of the zone to be masked depends on the position of the detector. Therefore, determine the mirror surface to be masked before removing the mirror from the detector. To block out a particular zone or group of zones, peel off a section of the mask that corresponds to the appropriate zone, and stick it on the mirror segment. Before attempting any masking, be sure the chosen mirror surface is the correct one. Refer to Figure 7.1 to identify mirror segments and zones. The coverage pattern consists of sensor zones arranged to form a circular coverage pattern. Using Motion Analyzer II circuitry, the detector must first see a change in infrared energy in one zone followed by a change of energy in the remaining zone. Therefore, disturbances that occur in only one finger do not constitute motion and are ignored. This “catch sensitivity” may be changed in the field by the installer to provide the degree of sensitivity required by the installation. Self-test and supervision circuits provide reliable operation in a variety of installation environments. The result is a highly advanced detector offering superior performance with freedom from false alarms. Specifications NOTICE! When disabling the look-down segment, do not mask segment 5 directly as this will disable the entire detector. Instead, mask the segment on the dome directly below segment 5. P AR8-13 P A C M-2 M-1 5 E-1 E-2 N E L E-3 F D I L F H AR8-13 2 3 4 5 Alarm Relay Silent-operating Form “C” relay. Contacts rated <100 mA, 25 VDC, 2.5W maximum, <20 Ohm closed for DC resistive loads. Tamper Contacts rated at 28 VDC, 125 mA maximum, <1 Ohm. Connect tamper circuit to a 24hour protection circuit. Trouble Output Maximum current load is 25 mA. Optional Accessory TC6000 test cord. G K J 1 6.0 to 15.0 VDC; 5 mA standby, 20 mA in alarm with LEDs enabled. Use only an Approved Limited Power Source. E M G K J Input Power C D M M-3 3.5 in. x 5.25 in. (8.9 cm x 13.3 cm) B O E-4 B O N M-4 A Dimensions (HxDia) 4 3 2 1 I H Figure 7.1: Mirror module to pattern reference NOTICE! When attempting to remove any masking, many adhesives will either destroy the mirror surface or leave enough residue behind to reduce coverage performance. 10 © 2013 Bosch Security Systems, Inc. F.01U.263.663 | 04 | 2013.04 | 3 2 Mounting 6.2 False Alarm Prevention Select a location likely to intercept an intruder moving beneath and across the coverage pattern. Refer to Figure 2.1. Recommended mounting height range is 8 to 18 feet (2.4 to 5.5 m). Turn on all heating and cooling sources that would normally be in operation during times of protection. Stand away from the unit and outside the coverage pattern, then monitor the background noise for at least three minutes. The surface should be solid and vibration-free. (i.e. Drop tiles should be secured if the area above the tiles is used as an air return for HVAC systems). 9m 30 ft 26 ft 30 ft 26 ft 30 ft 8m 26 ft 6m 20 ft 20 ft 13 ft 7 ft 0 ft 7 ft 13 ft 20 ft ≤18 ft ≤5.5 m 4.6 m ≥4.0 m 4m 13 ft 2m 7 ft 15 ft ≥13 ft AR13-18 0m 0m 0 ft 2m 7 ft 4m 13 ft 6m 20 ft 8m 26 ft 9m 30 ft Readings should not deviate from the reference level more than ±0.15 VDC. For readings outside these limits; eliminate the cause, rotate the unit slightly, or mask out the mirror segment(s) looking down at the thermal disturbance. 0 ft ≤4.0 m ≤13 ft 3.0 m ≥2.4 m 10 ft ≥8 ft AR8-13 0m 0 ft 8m 6m 4m 2m 0m 2m 4m 6m 9m When testing is completed, remove the TC6000 Test Cord, and twist-lock the cover into place. 6.4 Supervision Feature Enclosure release tabs Test lead cutout Optical module The DS938Z performs several supervision features that, combined with the advanced motion detection capabilities of the detector, provide an extremely high level of security. A supervision trouble condition is indicated at the detector by the Alarm/Test LED (see the Supervision Display Chart). • The LED indicates the cause of the supervision trouble using coded pulses. The supervision trouble signal activates the Trouble Output available at terminal 8, which should be connected to a 24-hour zone. The supervision features function as follows: Interface connector Cover twist tabs (4) Interface pins Figure 2.2: Opening cover NOTICE! Slightly rock the enclosure side-to-side during removal to overcome the friction caused by the base-to-enclosure terminal pins. 2. Open the cover by turning counterclockwise. 3. Route wiring as necessary to the rear of the base and through the center hole. Refer to Figure 2.3. 4 © 2013 Bosch Security Systems, Inc. A minimum voltage change of 1.0 VDC from the reference level is required in the wintertime when the background temperature is cool. This will make up for summertime, when the background is warmer. If testing the unit in the summertime, the minimum recommended voltage change is 0.75 VDC. 9m 1. Remove the base from the enclosure by pressing the two enclosure release tabs inward while lifting the enclosure away from the base. Refer to Figure 2.2. Anti-vandal locking screw holes (2) Again walk across the farthest edge of required coverage. 8m Figure 2.1: Coverage Pattern Enclosure release openings (2) 6.3 Coverage Margin LED CAUSE ON Unit alarm 2 Flashes Motion monitor time out 4 Flashes PIR self-test failure PIR: The operation of the PIR is electronically checked approximately every 12 hours. If the PIR fails, the Alarm/Test LED will flash four times and the Trouble Output will activate. Motion Monitor Supervision: This feature verifies that the detector has a clear view of the detection area and has not been blocked. When selected using switches S4 and S5, a supervision timer is activated. A trouble condition will be indicated if the detector has not alarmed at least once during the selected time period (this feature can be disabled by placing both switches in the Off position). The time period selected should be long enough to allow adequate time for holiday weekends. Refer to Section 4.0 Feature Selection for proper switch settings. F.01U.263.663 | 04 | 2013.04 | 9 NOTICE! The use of a Sonalert type device (sounder) will provide an audible tone during the time the unit is in alarm. Of the three available connector pins, the center pin is positive (+) with respect to either outside pin (outside pins are common (-)). Use of the sounder is intended only as an aid for walk testing during installation. CAUTION! Be sure all wiring is unpowered (de-energized) before routing. ANTI-T AMPER SCREW HOLE REQUIRED FOR EN50131 INST ALLA TIONS ALARM/TEST LED INDICATOR (3) SOUNDER 3. Place the cover on the unit, and twist-lock it clockwise into place. REAR WIRE ENTRANCE TEST LEAD CUTOUT NOISE VOLTAGE TERMINAL STRIP 1 WIRE TIE-DOWNS (2) INTERFACE PINS GAIN SELECT JUMPER ON F OF MOUNTING SLOTS (4) LO HI 8 NOTICE! Be sure the TC6000 and Sonalert leads are dressed through the cutout. LO 4. Apply power to the unit. HI 5. Wait at least two minutes, after applying power, to start walk tests. Mounting Base COVER TAMPER CONFIGURATION SWITCHES ANTI-TAMPER SCREW HOLE REQUIRED FOR EN50131 INSTALLATIONS Top View of Enclosure with Cover and Optical Module Removed NOTICE! Walk testing should be done across the coverage pattern as shown. Figure 2.3: Overview 6. The edge of the coverage pattern is determined when the Alarm/Test LED indicator (and optional Sonalert®, if installed) first turns on. 7. Walk test the unit from all directions to determine the boundaries. 4. Firmly mount the base. Depending on local regulations, the base may be directly surface mounted using anchors, mollies, or wing-nuts, or may be mounted to standard 4-inch octagonal or square electrical boxes. 8. After completion of the walk tests, remove the Sonalert® (if installed). NOTICE! The DS938Z base will not completely cover a 4-inch square box. Where aesthetics are important, a 4-inch octagonal box is recommended. 6 Final Tests 6.1 Noise Measurement NOTICE! Mounting to removable ceiling tiles is not recommended unless a sandwich is made of the base, ceiling tile, and a back plate behind the tile. Covers used for 4-inch octagonal and square boxes make a suitable back plate (when used with bolts and wing nuts, as an example). NOTICE! Meter readings are very important in determining background disturbance levels and catch margin sensitivity. 1. Connect a 20,000 ohm/volt (or greater) DC VOM to the Noise Voltage connector using the TC6000 as shown. Set meter scale for about 3.0 VDC. 2. The base reference level for reading background noise or target voltages is approximately 2.0 VDC. Installations in quiet environments, therefore, will result in a steady meter reading between 1.9 and 2.1 VDC. Look for areas and sources of thermal disturbances if the meter fluctuates greatly. 8 © 2013 Bosch Security Systems, Inc. 3 Wiring CAUTION! Only apply power after all connections have been made and inspected. Do not coil excess wiring inside detector. Use no smaller than #22 AWG (0.8 mm) wire in the terminal strip. F.01U.263.663 | 04 | 2013.04 | 5 • Standard Sensitivity: Tolerates environment extremes on this setting, but requires the largest amount of intruder motion to achieve an alarm. • Intermediate Sensitivity: The recommended setting for most installations. Use in locations where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting. The detector is shipped in Intermediate Sensitivity mode. • High Sensitivity: The setting for fast response to intruder signals. For use only in extremely quiet environments where ceiling drafts, and thermal and illumination transients are not anticipated. KEY GUIDE 2 – + 6 to 15 VDC 3 4 5 Alarm RELAY 6 7 TAMPER 8 TROUBLE 1 INTERFACE PINS Figure 3.1: Wiring to terminals If both switches are in the OFF position, the unit will default to the intermediate setting. Terminals 1 (-) & 2 (+): Power contacts. Terminals 3 (NO), 4 (C), & 5 (NC): Alarm relay contacts. Use terminals 4 & 5 for Normally Closed circuits. Do not use with capacitive or inductive loads. NOTICE! Although the sensitivity modes provide different degrees of tolerance to environmentally caused alarms, the installer should assure peak background noise voltage readings do not exceed ±0.15 VDC. (See Section 8.0 Final Tests). Terminals 6 (T) & 7 (T): Normally Closed tamper contacts. Terminal 8 (TR): Solid state Trouble output. Shorts to ground (-) when the detector is in a Trouble condition. 4 Feature Selection 4.3 Signal Gain The DS938Z has several features that are controlled using the configuration switches. The DS938Z permits selection of the signal gain depending upon the environment to be protected. The gain select jumper is located under the optical module. Refer to Figure 2.3. Motion Monitor Sensitivity LED 4 ON and 5 OFF = 4 Day 4 OFF and 5 ON = 30 Day 4 OFF and 5 OFF = Disabled 2 ON and 2 OFF and 2 ON and 3 OFF = High 3 ON = Intermediate 3 ON = Standard 1 ON 1 OFF ON OFF = = • High Gain: Recommended for large coverage applications up to 60 ft. (18.3 m) in diameter. The DS938Z is shipped in this setting. If the gain select jumper is missing, the unit will default to High Gain. • Low Gain: Recommended for applications where the area to be covered is 40 ft. (12.2 m) or less in diameter and for applications where High Gain may be too sensitive for environmental extremes. } } NOTICE! Setting the DS938Z for Low Gain reduces the coverage area to 40 ft. (12.2 m) in diameter. OPEN Figure 4.1: Selecting features 4.1 LED Operation ON: OFF: Allows the Alarm/Test LED to operate when activated by motion. The LED will not operate on alarm activation, but will indicate a supervision trouble condition. 5 Setup and Walk Testing 1. Attach a TC6000 Test Cord to the Noise Voltage terminals. Since the outside terminals are common, polarity is not important and the black lead may be toward or away from the optical module. 2. Attach a Sonalert to the sounder pins at this time if one will be used during walk testing. 4.2 Sensitivity Selection Sensitivity modes depend on the type of coverage desired and the installation environment. 6 © 2013 Bosch Security Systems, Inc. F.01U.263.663 | 04 | 2013.04 | 7
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : blt1fp Create Date : 2013:04:01 13:42:19-04:00 Modify Date : 2013:04:01 13:42:19-04:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : blt1fp Title : F01U263663-04_DS938Z_ING.indd Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 10.1.5 (Windows) Document ID : uuid:0ec41806-6f45-42a4-866c-f801b08a15b6 Instance ID : uuid:b22c31c1-58aa-4595-a28a-6aac118a47da Page Count : 6EXIF Metadata provided by EXIF.tools