Bradfordwhite Canada Commercial Volume Water Heater Brute Series 150 850 Bntv Submittal 2152J Bw 2152D NH.p65 User Manual
2152J-Bw 2152J-BW 2152J-BW uploads wp-content bradfordwhitecorp :
Commercial Volume Water Heater Brute Series 150 850 Bntv Submittal 2152J Bw commercial_volume_water_heater_brute_series_150_850_bntv_submittal_2152j_bw commercial_volume_water_heater_brute_series_150_850_bntv_submittal_2152j_bw uploads wp-content bradfordwhitecorp :
2017-01-11
User Manual: Bradfordwhite Canada Commercial Volume Water Heater Brute Series 150 850 Bntv Submittal 2152J Bw canada_commercial_volume_water_heater_brute_series_150_850_bntv_submittal_2152j_bw uploads wp-content bradfordwhitecorp :
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
NEOTHERM Brute ® Date: Volume VolumeWater Water Heater Heater BNTV NTV Volume Water Heater Indoor Sizes 150-850 Standard Equipment • Electronic PID modulating control with large color touchscreen display • Password-protected parameters for installer use • Test feature allows forced min or max firing • Complete diagnostics for analog and digital inputs • Displays holds, alerts and errors in clear text form • Dray alarm contacts for ignition failure • High condensing efficiency • Modulation down to 20% of full fire (5:1 turndown) • Sealed combustion chamber • Pre-mix stainless steel burner • Low NOx system exceeds the most stringent regulations for air quality - less than 10ppm NOx Heater Data Factory Mounted Options Number of Units: Project #: Submittal Data Submittal Data Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: • Horizontal or vertical direct vent • Horizontal vent and air terminals • Vent and air pipe lengths of up to 100 equivalent feet (each) • Built-in condensate trap • Vent temperature cutoff feature • Direct spark ignition system • Sensor for domestic water tank • 160 psi maximum working pressure • Stainless steel heat exchanger with welded construction (no gaskets) • ASME "H" stamp • 125 psi (861 kPa) ASME rated pressure relief valve • Water flow switch (399-850 only) • Temperature & pressure gauge Fuel ■ Natural Propane ASME "HLW" Stamp CSD-1 (covers FM & GAP) (500-850 only) ■ Low water cutoff (500-850 only) High & Low gas pressure switches (500-850) H Additional auto reset high limit 60 psi pressure relief valve 75 psi pressure relief valve 125 psi pressure relief valve (std) 150 psi pressure relief valve • Drain valve • Integrated PID temperature and ignition controls • Alarm output • Accepts external 4-20mA (0-10V with optional convertor) modulation signal • On/off toggle switch • Manual reset high limit • Burner site glass • Zero clearance to combustible surfaces • Built-in cascade function for up to Brutes. eight NeoTherms • 8 year limited warranty Pump included (150-500 only) No pump Bell for ignition failure Accessories for Field Mounting Water flow switch (285 only) Low water cutoff 0 - 10V convertor for modulation control High & Low gas pressure switches Sizing Data Input Model BNTV NTV 150 Clearances Boiler pump (285-500) Concentric vent terminal, 2" Concentric vent terminal, 3" Flush-mount terminal, 3" Flush-mount terminal, 4" Output BTU/h kW BTU/h kW Thermal Efficiency % 150,000 44.0 142,500 41.7 95 Propane conversion kit Condensate neutralizer kit BACnet gateway LON gateway Gas Conn. Size inches Water Conn. Size inches Shipping Weight lbs kg ½ NPT 1¼ NPT 228 103 BNTV NTV 199 199,000 58.3 193,030 56.5 97 ½ NPT 1¼ NPT 270 123 BNTV NTV 285 285,000 83.5 270,750 79.3 95 ¾ NPT 2 NPT 299 136 BNTV NTV 399 399,000 116.9 383,040 112.2 96 ¾ NPT 2 NPT 364 165 1 NPT 2 NPT 419 190 BNTV NTV 500 500,000 146.5 480,000 140.6 96 BNTV NTV 600 600,000 175.8 582,000 170.4 97 1 NPT 2 NPT 426 193 BNTV NTV 750 750,000 219.8 705,000 206.4 94 1½ NPT 2 NPT 481 218 BNTV NTV 850 850,000 249.1 816,000 238.9 96 1½ NPT 2 NPT 503 228 Suggested Service Access Clearance Appliance Surface inches cm Left Side 1 2.5 Right Side 12 31 Top 24 61 Back 6 15 Closet, Front 6 15 Alcove, Front 24 61 Vent – – Certified by CSA for zero clearance to combustible materials on all sides. Vent System Intake (Air) Exhaust (Vent) Maximum Allowable Size Pipe Pipe Equivalent Length* 150 3" 3" 100 ft 30 m 199 3" 3" 100 ft 30 m 3" 3" 20 ft 6.1 m 4" 4" 100 ft 30 m 399 4" 4" 100 ft 30 m 500 4" 4" 100 ft 30 m 40 ft 12 m 285 600 750 850 4" 4" **6"** **6"** 100 ft ** 4" 4" 40 ft 12 m 6" 6" 100 ft 30 m 4" 4" 40 ft 12 m 6" 6" 100 ft 30 m 30 m ** Installations in the U.S. require exhaust vent pipe that is a combination of PVC & CPVC complying with ANSI/ASTM D1785 F441, polypropylene pipe that complies with ULC S636, or stainless steel complying with UL1738. Installations in Canada require exhaust vent pipe that is certified to ULC S636. Intake (air) pipe may be ABS, PVC, CPVC or galvanized material. Installer must comply fully with manufacturer's installation instructions, including use of minimum exhaust length CPVC, to maintain ANSI Z21.13 safety certification. Closet and alcove installations do not allow the use of PVC under any circumstances * To calculate max equivalent length, measure the linear feet of the pipe, and add 5 feet (1.5m) for each elbow used. ** Allowed only if the vent pipe is no more than 20 equivalent feet longer than the air pipe. Heater Electrical Data Pump Connection Ratings Sizes Volts Phase Amps (System Pump and DHW Pump Connections) 150-850 120 Single 2* n/a 120 Single 7* 115V - Maximum 1HP 120 Single 8* 115V - Maximum 1 HP No pump 150-199 With pump 285-500 or 7.4A max With pump or 7.4A max *Minimum 15A circuit required Recovery Data GPH Delivered REQUIRED WATER TEMPERATURE RISE Size 40°F GPH 50°F GPH 60°F GPH 70°F GPH 80°F GPH 90°F GPH 100°F GPH 120°F GPH 140°F GPH 150 431 345 287 246 215 191 172 144 123 199 579 463 386 331 290 257 232 193 166 285 818 654 545 467 409 363 327 273 234 399 1153 923 769 659 577 513 461 384 329 500 1451 1161 967 829 726 645 580 484 415 600 1729 1383 1152 988 864 768 691 576 494 750 2170 1736 1447 1240 1085 964 868 723 620 850 2434 1947 1622 1391 1217 1082 973 811 695 L/h Delivered REQUIRED WATER TEMPERATURE RISE Size 22°C L/h 28°C L/h 33°C L/h 39°C L/h 44°C L/h 50°C L/h 56°C L/h 67°C L/h 78°C L/h 150 1629 1303 1086 931 814 724 651 543 465 199 2190 1752 1460 1251 1095 973 876 730 626 285 3091 2473 2061 1766 1545 1374 1236 1030 883 399 4359 3487 2906 2491 2181 1937 1744 1453 1245 500 5485 4388 3657 3134 2743 2438 2194 1828 1567 600 6536 5288 4355 3735 3266 2903 2612 2177 1867 750 8203 6562 5470 4687 4101 3644 3281 2733 2344 850 9201 7360 6131 5258 4600 4090 3678 3066 2627 Water Flow Requirements NORMAL WATER* Flow H/L Temp Flow H/L Temp Size gpm feet Rise °F lpm m Rise °C 150 19 57 15 72 17.4 8 199 25 28 15 95 8.5 8 285 36 33 15 98 10.1 8 399 50 35 15 189 10.7 8 500 63 28 15 239 8.5 8 600 60 24 19 227 7.3 11 750 68 35 21 257 10.7 12 850 68 26 24 257 7.9 13 *Maximum water hardness of 10 grains per gallon allowed L Dimensional Data Size in AIR INLET cm in cm VENT in cm 150 19½ 49 3 7.6 3 7.6 199 26¾ 68 3 7.6 3 7.6 285 26¾ 68 4 11 4 11 399 31½ 80 4 11 4 11 500 37¾ 96 4 11 4 11 600 37¾ 96 4 11 4 11 750 51 130 4 11 6 17 850 55¼ 140 4 11 6 17 Dimensions are nominal and are shown in inches, cm. **NeoTherm is shipped with adapters forair theand air vent and vent Brute is shipped with adapters for the that that accept standard pipe the proper sizetype. and type. accept standard pipe of theofproper size and A Size in B cm in cm C in D cm in E cm in F cm in G cm in J cm in K cm M in cm in N cm in cm 150 13¼ 34 5¼ 14 19 48 3¼ 8 10¾ 28 7½ 19 14¼ 36 19½ 49 7½ 19 15¼ 39 13 33 199 20½ 52 5¼ 14 19 48 3¼ 8 17¾ 45 7½ 19 14¼ 36 19½ 49 11¾ 30 15¼ 39 13 33 285 20¼ 52 7¼ 19 19¾ 50 4¼ 16 11¼ 29 13½ 34 43 18¾ 48 13 33 399 25 64 5¼ 13 19¾ 50 4¼ 11 14¾ 37 18½ 47 19¼ 49 21¾ 55 18¾ 48 13 33 500 30¼ 77 5¼ 13 19¾ 50 4¼ 11 15¼ 38 20 51 20½ 52 18¾ 48 13 33 20 51 14 36 15 38 16½ 42 19 48 600 29¾ 76 5 13 19½ 50 4¼ 11 15 38 3 8 19 48 750 35½ 90 6 15 19½ 50 5¼ 13 19 48 40½ 103 3¼ 8 19 48 850 39¾ 101 6 15 19½ 50 5¼ 13 19 48 44¾ 114 3½ 9 19 48 17 26 66 26 66 18¾ 48 8¼ 21 30¾ 78 18¾ 48 8¼ 21 18¾ 48 8¼ 21 35 89 Laars Heating Systems Company reserves the right to change specifications, components, features, or to discontinue products without notice. 200 Lafayette St. www.BradfordWhite.com Middleville, MI 49333 Customer Service and Product Support: 800.900.9276 • Fax 800.559.1583 Litho in U.S.A. © Bradford White 1608 Document 2152J-BW Warranty: (800) 531-2111 Headquarters: 20 Industrial Way, Rochester, NH, USA 03867 • 603.335.6300 • Fax 603.335.3355 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : dsalerno Create Date : 2011:09:23 10:12:44-07:00 Modify Date : 2016:08:29 13:43:14-04:00 Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 6.0 (Windows) Creator Tool : PageMaker 6.5 Metadata Date : 2016:08:29 13:43:14-04:00 Document ID : uuid:90943fa6-9157-48a0-a0eb-eabb3488df69 Instance ID : uuid:cb6bd22a-eb61-4bfa-8cd3-e134721791db Format : application/pdf Title : 2152D-NH.p65 Creator : dsalerno State : 1 Version : 1.1 Page Layout : SinglePage Page Mode : UseThumbs Page Count : 4EXIF Metadata provided by EXIF.tools