Bruker Optik BRAVO-01 TiWi-BLE Transceiver Module User Manual BRAVO Analyzer EN

Bruker Optik GmbH TiWi-BLE Transceiver Module BRAVO Analyzer EN

User Manual

Download: Bruker Optik BRAVO-01 TiWi-BLE Transceiver Module User Manual BRAVO Analyzer EN
Mirror Download [FCC.gov]Bruker Optik BRAVO-01 TiWi-BLE Transceiver Module User Manual BRAVO Analyzer EN
Document ID2658216
Application IDsnyGwS//kHOzTPlKRj+cCA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize120.26kB (1503215 bits)
Date Submitted2015-06-25 00:00:00
Date Available2015-06-25 00:00:00
Creation Date2015-06-25 13:18:34
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2015-06-25 14:16:12
Document TitleBRAVO Analyzer_EN.book
Document CreatorFrameMaker 10.0.2
Document Author: mafe

rs
io
BRAVO
ve
Handheld Raman Spectrometer
ra
ft
User Manual
1837209
rs
io
ve
ft
ra
1st edition 2015, publication date May 2015
© 2015 BRUKER OPTIK GmbH, Rudolf-Plank-Straße 27
D-76275 Ettlingen, www.bruker.com/optics
All rights reserved. No part of this manual may be reproduced or transmitted in any form
or by any means including printing, photocopying, microfilm, electronic systems etc. without our prior written permission. Brand names, registered trademarks etc. used in this
manual, even if not explicitly marked as such, are not to be considered unprotected by
trademarks law. They are the property of their respective owner.
This manual is the original documentation for the handheld Raman spectrometer
BRAVO.
Table of contents
Table of contents
General safety information.................................................................................... 5
1.2
Classification of the safety notes ......................................................................... 5
1.3
Overview of possible types of hazard .................................................................. 6
1.3.1
Possible hazards during installation and operation .................................................. 6
Possible hazardous sample materials...................................................................... 7
1.4
Laser safety ............................................................................................................ 8
1.4.1
Laser class ............................................................................................................... 8
1.4.2
Safety instructions .................................................................................................... 8
1.4.3
Laser exit points ....................................................................................................... 9
1.4.4
Laser status LED.................................................................................................... 10
1.4.5
Enabling / disabling the laser ................................................................................. 11
1.4.5.1
1.4.5.2
1.4.5.3
How to enable the laser ......................................................................................... 11
How to disable the laser ........................................................................................ 11
How to abort a running measurement .................................................................... 12
1.5
Fire safety ............................................................................................................. 12
1.6
Battery safety instructions .................................................................................. 13
1.7
Safety notes regarding the LCD.......................................................................... 13
1.8
Electromagnetic compatibility (EMC)................................................................. 14
1.9
Intended use ......................................................................................................... 14
1.10
Service contact data ............................................................................................ 15
ve
rs
io
1.3.2
General information ....................................................................................17
2.1
Fields of application............................................................................................. 17
2.2
Technical feature.................................................................................................. 17
2.3
Scope of delivery.................................................................................................. 18
2.4
Inspecting the packaging .................................................................................... 19
2.5
Ambient conditions and power supply .............................................................. 19
BRAVO analyzer - Overview .......................................................................21
1.1
ft
Safety..............................................................................................................5
ra
3.1
Components and control elements - Overview ................................................. 21
3.2
Laser status LED ................................................................................................. 22
3.3
Measuring tip ........................................................................................................ 23
3.4
Button panel - Control buttons ........................................................................... 24
3.5
Touchscreen ......................................................................................................... 24
3.6
Docking station .................................................................................................... 25
Operation......................................................................................................27
4.1
Switching on / off BRAVO .................................................................................. 27
4.2
Logging in ............................................................................................................. 28
4.3
Scanning the barcode of the sample.................................................................. 29
4.4
Exchanging the measuring tip ............................................................................ 30
4.5
Verifying a sample ............................................................................................... 31
Bruker Optik GmbH
BRAVO Analyzer - User Manual
Table of contents
4.6
Recharging the battery ........................................................................................ 35
4.8.1
General information ................................................................................................ 35
4.8.2
Recharging the battery with the battery charger..................................................... 36
4.8.3
Recharging the battery via the docking station....................................................... 37
4.9
Establishing a wireless connection between BRAVO and a data station....... 38
4.9.1
Connecting the data station to the WLAN .............................................................. 38
4.9.2
Connecting BRAVO to the WLAN .......................................................................... 39
4.9.3
Connecting the data station to BRAVO via WLAN ................................................. 41
4.10
Establishing a wired connection between BRAVO and a data station............ 42
4.10.1
General information ................................................................................................ 42
4.10.2
Possible connection variants .................................................................................. 42
4.10.3
Assigning network addresses to BRAVO ............................................................... 45
4.10.4
Connecting BRAVO to data station ....................................................................... 47
4.10.5
Checking the connection between BRAVO and data station ................................. 47
4.11
Mounting / demounting the carrying strap ........................................................ 48
4.11.1
General information ................................................................................................ 48
4.11.2
Procedure ............................................................................................................... 48
ve
Cleaning and Decontamination..................................................................51
5.1
Cleaning the BRAVO analyzer............................................................................. 51
5.1.1
Cleaning the plastic cover ...................................................................................... 51
5.1.2
Cleaning the touchscreen....................................................................................... 51
5.2
Decontaminating the BRAVO analyzer............................................................... 52
5.2.1
Approved decontaminating agents ......................................................................... 52
5.2.2
Decontamination procedure ................................................................................... 52
Repair ...........................................................................................................53
6.1
6.2
General information ............................................................................................. 53
Procedure.............................................................................................................. 53
Troubleshooting ..........................................................................................55
rs
io
Exchanging the battery........................................................................................ 34
4.8
ft
4.7
ra
Aborting a running measurement....................................................................... 33
7.1
General information ............................................................................................. 55
7.2
Problem - possible cause - solution ................................................................... 55
7.2.1
BRAVO does not boot up ....................................................................................... 55
7.2.2
Log in attempt failed ............................................................................................... 56
7.2.3
Barcode cannot be scanned................................................................................... 56
7.2.4
Black touchscreen display ...................................................................................... 57
7.2.5
Failed PQ test / OQ test ......................................................................................... 57
7.2.6
Aborted measurement ............................................................................................ 57
7.2.7
Problems regarding the detected spectral signal ................................................... 58
7.2.8
Problems regarding wireless data transfer ............................................................. 58
7.2.9
Problems regarding the docking station ................................................................. 59
Specification ................................................................................................61
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Table of contents
BRAVO ................................................................................................................. 61
A.2
Environmental conditions ................................................................................... 61
A.3
Battery and battery charger ................................................................................ 62
A.3.1
Battery ................................................................................................................... 62
A.3.2
Battery charger ...................................................................................................... 62
A.4
Docking Station ................................................................................................... 62
A.5
WiFi module .......................................................................................................... 63
A.6
Barcode reader ..................................................................................................... 63
A.6.1
Depth of field range ............................................................................................... 63
A.6.2
Resolution ............................................................................................................. 63
rs
io
Orderable items ...........................................................................................65
B.1
Spare parts & replacement parts ........................................................................ 65
B.2
Reference standards and certified samples ...................................................... 65
B.3
Consumables........................................................................................................ 66
B.4
Cleaning utensils.................................................................................................. 66
B.5
Optional parts ....................................................................................................... 66
B.6
Network equipment .............................................................................................. 67
ra
ft
ve
A.1
Bruker Optik GmbH
BRAVO Analyzer - User Manual
D
ra
ft
ve
rs
io
Table of contents
BRAVO Analyzer - User Manual
Bruker Optik GmbH
1
Safety
1.1
General safety information
➣ Read carefully all instructions and safety notes in this manual before putting the
handheld Raman spectrometer BRAVO into operation. Keep the manual for future
reference available at any time at a suitable place.
rs
io
➣ Always observe the instructions and safety notes given in this manual. Failure to
do so can lead to severe personal injuries and/or property damage. Non-observance of the instructions and safety notes also violates the intended use of the
handheld Raman spectrometer BRAVO. (See section 1.9.)
➣ It is the operator's duty to plan and implement all necessary safety measures and
to supervise their observance. Moreover, the operator must ensure that the handheld Raman spectrometer BRAVO is in proper condition and fully functioning.
➣ A safe and trouble-free operation of the handheld Raman spectrometer BRAVO is
ensured only if it is operated, maintained and repaired according to the procedures described in this manual and in compliance with all relevant safety standards and regulation.
ve
➣ The handheld Raman spectrometer BRAVO should be operated only by authorized personnel which is trained in operating the instrument and which is familiar
with the relevant safety instructions and laser safety regulations.
➣ Do never remove or deactivate any supporting safety systems during the operation.
ft
The handheld Raman spectrometer BRAVO has been developed according to the
safety regulation EN 61010-1:2010 (IEC 61010-1:2010+Cor.:2011) for electrical
equipment for measurement, control and laboratory use.
Classification of the safety notes
ra
1.2
Depending on the degree of hazard, important safety notes are classified in this manual
by signal words as follows:
DANGER
➣ Indicates a hazardous situation which, if not avoided, will result in death or serious
(possibly irreversible) injury and major property damage.
WARNING
➣ Indicates a hazardous situation which, if not avoided, could result in death or serious (possibly irreversible) injury and major property damage.
CAUTION
➣ Indicates a hazardous situation which, if not avoided, may result in minor or moderate (reversible) injury and minor property damage.
Bruker Optik GmbH
BRAVO Analyzer - User Manual
Safety 1
NOTICE
➣ Indicates a practice which could result in property damage if the given instructions
are not observed.
The symbol will draw your attention to additional pieces of information which might be
useful for you.
Overview of possible types of hazard
1.3.1
Possible hazards during installation and operation
rs
io
1.3
Hazards that can possibly occur during operating the analysis instrument BRAVO are
indicated by the appropriate warning symbols. The following warning symbols indicate
different dangerous situations which may be caused by an improper use of the analysis
system:
Definition
ve
Warning
symbol
General hazard:
ft
This warning symbol indicates general hazard. The label is located
near the danger spot in question. Observe the safety instructions and
follow the precautions described in the manual to avoid personal injury
and/or property damage.
ra
Laser radiation:
This warning symbol indicates the existence of laser radiation. The
label is located near the opening at which hazardous laser radiation
exits the instrument. Do not look directly into the laser beam or use
any kind of optical instruments to look into the beam as this may cause
permanent eye damage.
➣
Electrical shock:
This warning symbol indicates electrical hazard. It is located near live
parts or enclosures behind which are live parts that represent an accidental contact hazard. Do not touch these parts. Before removing the
corresponding housing part and beginning any repair works, first turn
off the mains power switch and unplug the power cord. Prevent all live
parts from coming into contact with a conductive substance or liquid.
Non-observance of the relevant safety instructions can cause severe
injury and/or property damage.
Important note: All warning labels on the analysis system BRAVO must always be
kept legible. Immediately replace a worn or damaged label.
BRAVO Analyzer - User Manual
Safety 1
1.3.2
Possible hazardous sample materials
There can also be hazards caused by the sample material. Depending on the type of
hazardous substances you analyze, you have to observe specific substance-relevant
safety instructions. Affix the corresponding warning label on the appropriate BRAVO
position. The label must be well legible and permanently discernible. The following list
contains some examples of hazardous substances:
Symbol
Definition
rs
io
Infectious material
This warning symbol indicates the possible existence of biologically
dangerous and infectious material. When working with this kind of
material always observe the prevailing laboratory safety regulations
and take necessary precautions and disinfection measures (e.g. wearing protective clothing, masks, gloves etc.). Non-observance may
cause severe personal injury or even death.
For information on how to use, dilute and efficiently apply disinfectants,
refer to the Laboratory Biosafety Manual: 2004 by WHO - World Health
Organization.
ve
Radioactive material
This warning symbol indicates the possible existence of radioactivity.
When working with radioactive material always observe the safety regulations and take necessary protective measures. Wear protective
clothing, e.g. masks and gloves. Non-observance may cause severe
personal injury or even death.
ra
ft
Corrosive substances
This warning symbol indicates the possible existence of corrosive substances. When working with corrosive substances always observe the
laboratory safety regulations, and take protective measures (e.g. wear
protective masks and gloves). Non-observance may cause severe personal injury or even death.
Important note: In case you have analyzed substances which are dangerous to
health you have to decontaminate the BRAVO analyzer completely before you
return it to Bruker for repair purposes. In addition, you have to add a declaration with
which you confirm that the BRAVO analyzer is completely free of any hazardous
substances. See chapter 6.
➣
Waste disposal
Dispose all waste produced (chemicals, infectious and radioactively contaminated substances etc.) according to the prevailing laboratory regulations. Detergents and cleaning
agents must be disposed according to the special waste regulations.
BRAVO Analyzer - User Manual
Safety 1
1.4
Laser safety
1.4.1
Laser class
The handheld Raman spectrometer BRAVO is classified as a laser class 1M product
according to IEC/EN 60825-1:2007. It emits invisible laser radiation in the wavelength
range 700nm to 1100nm (Popt. < 100nm).
rs
io
Laser class 1M product means that the product is safe for all reasonable foreseeable
conditions of use. This means, no laser safety equipment is required for operating
BRAVO.
This laser warning label identifies BRAVO as a
laser class 1M product. It is affixed at the
bottom side of the handheld Raman
spectrometer.
☞
1.4.2
ve
The duration of the laser radiation emission is limited automatically to the duration of the
spectroscopic measurement.
For information about the laser exit points, see section 1.4.3.
Safety instructions
ra
ft
Although BRAVO is a laser class 1M product, circumstances may occur in which laser
radiation poses a potential health hazard. In these cases, observe the following safety
instructions:
WARNING
Health hazard because of exposure to laser radiation
Non-observance of the following safety instructions can result in serious injury (possibly irreversible eye injuries).
➣ Do not place magnifying optics (e.g. magnifying glass) into the exiting laser beam
which focuses the laser beam. A focussed laser class 1M beam is capable of
causing eye injuries. Note: Means used for the correction of vision defects like eye
glasses or contact lenses do not pose an injury risk to the human eye in this context.
➣ In case the housing is damaged (e.g. parts of the housing are broken away) do
not start a measurement. Otherwise, there is a potential risk of laser radiation
emission. Instead, switch off the BRAVO spectrometer immediately and remove
the battery. Contact the Bruker service.
☞ For information about how to switch off BRAVO, see section 4.1. For information
about how to remove the battery, see section 4.7. For the Bruker service contact
data, see section 1.10.
BRAVO Analyzer - User Manual
Safety 1
1.4.3
Laser exit points
The location of the laser exit point depends on the type of installed measuring tip. Only
as long as a spectroscopic measurement is in progress, invisible laser radiation of laser
class 1M exits the handheld Raman spectrometer at the following exit points:
In case of an installed measuring tip
for vials, diffusely scattered laser
radiation exits BRAVO.
ra
ft
ve
rs
io
In case of an installed measuring tip
for bags, directed laser radiation
exits BRAVO.
Important note: If there is not any
measuring tip installed, the user cannot start a measurement neither by
pressing the Start Measurement button
at the BRAVO spectrometer
nor by touching the Collect Data icon
on the touch screen. This safety
feature prevents an accidental laser
emission in case no measuring tip is
installed.
BRAVO Analyzer - User Manual
Safety 1
1.4.4
Laser status LED
The laser LED informs you about the current
laser status as follows:
Laser status LED
• Laser LED is off: Laser is disabled (i.e. it is
not ready for emitting radiation).
• Blue solid: Laser is enabled (i.e. it is ready
for emitting radiation) and the laser safety
status of the instrument is OK.
rs
io
• Red solid: Laser emits radiation (for measurement purposes). As soon as the measurement is finished, the laser LED will
return to blue (solid).
ra
ft
ve
• Blue flashing: This indicates a laser safety
problem. In this case, you can not start a
measurement. Contact the Bruker service.
See section 1.10.
10
BRAVO Analyzer - User Manual
Safety 1
1.4.5
Enabling / disabling the laser
In the enabled state, the laser is switched on and ready to emit radiation, but it does not
emit radiation. The laser does not emit radiation before the user actively starts a measurement by pressing the button
at the BRAVO spectrometer or tapping the icon
on the touchscreen display. The duration of the laser radiation emission is automatically
limited to the measurement time. In the disabled state, the laser is switched off. In this
case, a spectroscopic measurement cannot be performed.
1.4.5.1
How to enable the laser
Enabling the laser
Switch on BRAVO by pressing the ON /
OFF button .
rs
io
1.
After you have switched on BRAVO, the
laser status LED is still off. This indicates
that the laser is not yet activated.
2.
Enable the laser by pressing the button
at the BRAVO button panel.
ve
➣
1.4.5.2
The laser status LED lights blue. This
indicates that the laser is ready for emitting radiation and laser safety status is
OK.
i Before starting a measurement, make sure
that the laser is enabled. When you start a
measurement with a disabled laser,
BRAVO aborts the measurement and
delivers a result of the category Aborted.
The reason stated for the abortion is Laser
not enabled.
ra
ft
➣
How to disable the laser
Disabling the laser (e.g. in case of emergency)
Press the button
panel.
➣
at the BRAVO button
This action switches off the laser i.e. it is
not ready for emitting radiation any
more. As a consequence, the laser status LED turns off.
Note: To re-enable the laser, press again the
at the BRAVO button panel.
button
BRAVO Analyzer - User Manual
11
Safety 1
1.4.5.3
How to abort a running measurement
➣
Note: BRAVO emits laser radiation only for the duration of the spectroscopic
measurement (data collection).
rs
io
Either Press to Abort on the touch screen display...
at the
1.5
ra
ft
ve
... or disable the laser by pressing the button
BRAVO button panel.
Fire safety
For analyzing purposes, the sample is exposed to laser radiation. This laser radiation
has the capacity to ignite highly flammable materials. So especially in case of highly
flammable substances, there is a potential fire hazard.
WARNING
Fire hazard when analyzing a highly flammable substance
Non-observance of the following safety instruction could result in serious injury and/
or property damage.
➣ Do not analyze knowingly a highly flammable substance.
➣ When analyzing unknown material, be aware of the potential fire hazard and take
appropriate precautions (e.g. a fire extinguisher within reach).
12
BRAVO Analyzer - User Manual
Safety 1
1.6
Battery safety instructions
WARNING
Health hazard because of an exploding battery
Non-observance of the following safety instructions can result in serious injury and /
or property damage.
rs
io
➣ Do not expose the battery to fire, sparks or glowing embers. Do not dispose the
battery in fire. Otherwise, it will explode. Risk of explosion and fire!
NOTICE
➣ Avoid excessive physical shock or vibration.
➣ Do not short-circuit the battery terminals.
➣ Do not disassemble or deform the battery.
➣ Do not use a battery which has visible signs of damage.
1.7
ve
➣ Do not immerse the battery in water or other liquids. Do not allow the battery to
get wet.
Safety notes regarding the LCD
ra
ft
The liquid crystal in the LCD is poisonous. During normal operation, it does not pose any
health hazard. However, should the touchscreen display break and liquid crystal leaks,
be careful.
CAUTION
Health hazard because of improper handling of leaking liquid crystal
Non-observance of the following safety instructions can result in minor injury.
➣ Avoid any skin contact. If you your skin or clothes have come in contact with liquid
crystal, wash it off immediately using soap and water.
➣ Do not put liquid crystal in your moth.
BRAVO Analyzer - User Manual
13
Safety 1
1.8
Electromagnetic compatibility (EMC)
EU regulations
The BRAVO analyzer has been developed according to EN 61326-1:2013 Electrical
equipment for measurement, control and laboratory use - EMC requirements - Part 1:
General requirements. The BRAVO analyzer is a class A equipment.
Class A equipment is suitable for the use in all establishments other than domestic and
those directly connected to a low voltage power supply network which supplies buildings
used for domestic purposes.
Important note: In a domestic environment, BRAVO may cause radio interference.
In this case, the operator may be required to take corrective actions in order to stop
radio interference.
rs
io
➣
US / FCC regulation
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment.
Important note: This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may
cause interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
ve
➣
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Intended use
ft
1.9
ra
BRAVO is a handheld spectrometer intended for Raman spectroscopic measurements
and subsequent qualitative evaluation for the purpose of raw material verification.
Due to the measurement technique, BRAVO is suited for analyzing all kinds of solid and
liquid samples which are Raman active, excluding highly flammable substances for
safety reasons.
BRAVO is intended for indoor usage under the ambient conditions specified in
appendix A.2.
The intended use includes also the compliance with the relevant standards and regulations, especially:
•
EN 60825-1 - Safety of laser products - Part 1: Equipment classification and
requirement
•
national and local safety regulations
•
national and local accident prevention regulations
•
generally recognized technical regulations
The intended use also includes the strict observance of all instructions given in this manual, namely:
14
•
safety instructions
•
operation and handling instructions
•
cleaning instructions
BRAVO Analyzer - User Manual
Safety 1
WARNING
Health hazard because BRAVO is used other than for its intended
purpose
Non-observance of the following safety instruction could result in serious injury (possibly irreversible skin and/or eye injuries).
1.10
Service contact data
rs
io
➣ Use BRAVO only as intended. Do not take any action that violates the intended
use. The operational safety BRAVO is ensured only if it is used as intended.
In case you have questions about safety, operation and / repair of the BRAVO analyzer
or you need technical assistance in case of a hardware and / or software problem, you
can contact the Bruker service as follows:
Service hotline hardware:
•
Service hotline software:
Fax:
•
E-mail:
+49 (0) 7243 504-2030
+49 (0) 72 43 504-2100
Service.BOPT.DE.mailing@bruker.com
ve
•
+49 (0) 72 43 504-2020
On our website www.bruker.com/about-us/offices/offices/bruker-optics you will
find also the current contact data of all Bruker Optics services offices worldwide.
ra
ft
☞
•
BRAVO Analyzer - User Manual
15
D
ra
ft
ve
rs
io
Safety 1
16
BRAVO Analyzer - User Manual
2
General information
2.1
Fields of application
BRAVO is a handheld Raman spectrometer designed for raw material verification and
raw material identification. It is approved for indoor usage only, namely in laboratory and
warehouse environments. A typical field of application is the incoming goods inspection.
2.2
Technical feature
rs
io
There are two different types of measuring tips which are interchangeable. These measuring tips can be used for measuring liquid and solid samples being filled in a vial or in
a plastic bag, in a barrel, for example. With BRAVO, the samples are measured in a noncontact way.
The BRAVO analyzer is characterized by the following technical features:
Duo LaserTM excitation
ve
The BRAVO analyzer is equipped with two laser diodes which emit radiation in the wavelength range between 700nm and 1100nm. This dual laser excitation provides for a very
high sensitivity across the entire spectral range. This in turn ensures a very high degree
of unambiguous sample identification.
Fluorescence mitigation by sequentially shifted excitation (SSETM)1
ft
Normally, the Raman spectroscopic measurement technique is not suitable for samples
which tend to fluoresce when being exposed to laser radiation because sample fluorescence can yield a much more intense signal than the Raman scatter of the sample,
masking any Raman bands in the spectrum.
ra
The patented SSETM technique, however, allows for obtaining pure Raman spectra even
in the presence of intense fluorescence by exciting the sample with a sequentially
shifted laser radiation. Due to the implemented fluorescence mitigation technique
SSETM, BRAVO can also be used for measuring samples which tend to fluoresce when
being exposed to laser radiation.
Inbuilt wavenumber calibration
The automated wavenumber calibration ensures highly reproducible measurement
results and an unmatched wavenumber accuracy. They are crucial for a raw material
identification in a validated environment.
Automatic recognition of the measuring tip
BRAVO recognizes automatically the currently installed type of measuring tip. In addition, this information is stored automatically in the measurement records.
1. US patent 8,570,507, other patents pending
BRAVO Analyzer - User Manual
17
General information 2
In case, the user has explicitly defined a certain type of measuring tip for a certain sample when setting up a library, than BRAVO automatically prompts the user to use the previously defined tip for measuring the sample in question. This special feature prevents
the user from measuring a certain sample using the wrong measuring tip.
The design of the measuring tip allows for an easy interchange and ensures always a
precise positioning.
Wireless and wired data transmission
2.3
rs
io
BRAVO is equipped by default with an integrated WLAN device. This technical feature
allows for a wireless data exchange between the BRAVO analyzer and a PC station via
a wireless network. If demanded, the wireless connectivity can be deactivated. Alternatively, a wired data transmission via an Ethernet network is also possible by using the
optional docking station.
Scope of delivery
The items of the default delivery scope are delivered in a robust carrying case.
The carrying case includes the following items:
• handheld Raman spectrometer BRAVO with installed
BRAVO software
• 1x measuring tip for vials
• 1x measuring tip for bags
• 2x rechargeable batteries (Note: The rechargeable
batteries are delivered in a charged state.)
• 1x battery charger
• 1x polystyrene standard (reference standard for OQ
and PQ test measurements)
• 1x calcite standard (reference standard for OQ test
measurement)
• 1x microfibre cloth
• 1x carrying strap (including the required items and
tools for mounting / demounting the strap)
• OPUS software delivered on an USB stick (including
OPUS online help) Note: By default, the following
OPUS software packages are delivered: OPUS/IR,
OPUS/BRAVO, OPUS/SEARCH and OPUS/VALIDATION.
• Quick Start Guide (printed version)
• BRAVO Analyzer User manual and BRAVO Software
User Manual (electronic version, delivered on an USB
stick)
ra
ft
ve
Standard Components:
Optional Components:
18
• Docking station with power cord and external power
supply unit (Note: The docking station is delivered in a
storage case.
• 1x Ethernet cable (crossover)
• Validation kit containing the following Raman reference
standards: 1x vial cyclohexane, 1x vial naphthalene,
1x vial benzonitrile, 1x vial tylenol, 1x PE bag tylenol
with certificate-of-origin
• Bruker validation manual
• optional OPUS software packages (e.g. OPUS/IDENT)
• Data system
BRAVO Analyzer - User Manual
Bruker Optik GmbH
General information 2
2.4
Inspecting the packaging
After having received the BRAVO analyzer, inspect the packaging for damages.
CAUTION
Possible damage to the delivered goods because of transport damage
Non-observance of the following safety instructions could result in injury.
➣ Check the packaging visually or damages. If there are signs of damage contact
the shipping company.
rs
io
➣ A BRAVO analyzer delivered in a damaged packaging may be damaged as well.
Therefore, do not put BRAVO into operation in this case. Contact Bruker instead.
(See section 1.10.)
2.5
Ambient conditions and power supply
ve
For proper and error-free operation of the instrument, ensure that the following conditions are met:
ra
ft
Ambient conditions /
environmental requirements:
Power supply:
Bruker Optik GmbH
• Approved for indoor use only (in laboratory and
warehouse)
• Ambient temperature range: 5°C - 35°C (41°F to
95°F)
• Humidity (non-condensing): 0 - 95 % (relative
humidity)
• BRAVO is shielded against electromagnetic interferences. Nevertheless, the instrument should not be
installed near high electric and/or magnetic fields.
BRAVO is designed for both battery operation (standard) and mains operation (option).
Note: For mains operation, put BRAVO in the docking
station. The docking station is an optional item. In this
case, the power supply has to fullfil the following
requirements: 100 - 240 VAC ± 10%, 50/60 Hz
☞
For information about battery specifications, see
appendix A.3.
☞
For information about how to recharge a battery,
see section 4.8.
BRAVO Analyzer - User Manual
19
D
ra
ft
ve
rs
io
General information 2
20
BRAVO Analyzer - User Manual
Bruker Optik GmbH
3
BRAVO analyzer - Overview
3.1
Components and control elements - Overview
Top side
①
rs
io
②
① - Laser status LED
② - Measuring tip (exchangeable)
③ - Touchscreen
④ - Start measurement button
③
⑤ - Laser enabling / disabling button
⑥ - ON / OFF button
⑧
ve
⑦ - Barcode scanner button
⑧ - Carrying strap (removable)
⑦
⑥
ft
④
⑤
ra
Bottom side
⑫
⑨ - Contact bar for the docking station
⑨
⑩
⑩ - Laser label
⑪ - Type label
⑫ - FCC label
⑪
Bruker Optik GmbH
BRAVO Analyzer - User Manual
21
BRAVO analyzer - Overview 3
Front side
⑬ - Measuring tip (exchangeable)
⑭ - Barcode reader
⑬
⑭
rs
io
Back side
⑮ - Battery compartment door
(removable)
⑮
Laser status LED
ve
3.2
Laser status LED is off.
ra
ft
➣
The laser is disabled (i.e. it is not ready
for emitting radiation).
Laser status LED lights continuously blue.
➣
Laser is enabled (i.e. it is ready for emitting radiation) and laser safety status is
OK.
Laser status LED lights up red.
➣
Laser emits radiation.
Note: The red laser status LED is of a temporary nature only. As soon as the measurement
is finished, the laser status LED returns to blue
indicating that the laser radiation emission is
over.
Laser status LED is flashing blue.
➣
☞
22
This indicates a laser safety problem. In
this case, you cannot start a measurement. Contact the Bruker service.
For service contact data, see section 1.6.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
BRAVO analyzer - Overview 3
3.3
Measuring tip
Depending on the type of container in which the sample material is filled, there are two
different types of measuring tips: a measuring tip for vials and a measuring tip for bags.
Measuring tip for vials
(for measuring liquid or solid samples being filled in a vial)
ve
rs
io
Laser
Vial
Laser
ra
ft
Measuring tip for bags
(for measuring samples being filled in a plastic bag, in a barrel etc.)
Sample
Bruker Optik GmbH
The available measuring tips are automatically recognized by the BRAVO analyzer when
they are attached. The type of measuring tip and relevant data about the measuring tip are
stored with each measurement.
BRAVO Analyzer - User Manual
23
BRAVO analyzer - Overview 3
3.4
Button panel - Control buttons
The button panel includes the following control buttons:
ON / OFF button
Depending on whether the BRAVO analyzer is currently
on or off, pressing this button switches BRAVO on or off.
Laser enabling / disabling button
➣
rs
io
Pressing this button enables or disables the laser. (Note:
In the enabled state, the laser is ready to emit radiation.)
An enabled laser is indicated by a blue laser LED.
When the laser is disabled, the laser LED is off.
Barcode scanner button
When you press this button, the barcode reader scans the
barcode placed in front of it.
Note: Alternatively, you can start the barcode scanning
process using the BRAVO software.
ve
Start measurement button
Pressing this button starts the spectroscopic measurement.
Note: Alternatively, you can start the measurement using
the BRAVO software.
Touchscreen
ft
3.5
ra
General information
BRAVO is equipped with high-resolution TFT display with touchscreen 7" (15.0 cm x
9.4 cm).
Handling instructions
NOTICE
Damaged touchscreen because of improper handling
Observe the following handling and operating instructions to avoid damages.
➣ Operate the touchscreen only with your fingers. Do not use a sharp object
because it can damage of scratch the display surface.
➣ Do not touch the touchscreen with a conducting metallic object as this can cause
interferences / lead to a touchscreen disfunction.
➣ Operate the touchscreen only with clean and dry fingers.
➣ Clean the touchscreen only as described in section 5.1.2.
24
BRAVO Analyzer - User Manual
Bruker Optik GmbH
BRAVO analyzer - Overview 3
3.6
Docking station
The docking station is an optional item. It provides for:
a data transfer (up-/downloading data) via Ethernet network (wired network)
between BRAVO and the data station on which OPUS is installed
•
recharging the battery inside BRAVO and the spare battery which is stored
inside the docking station
•
storing the measuring tip which is currently not used and the reference sample
for the PQ test
•
data transfer via USB stick
rs
io
•
①
⑨
⑧
③
ve
②
ft
⑦
④
⑥
⑤
ra
① - Contact bar for connecting with BRAVO
② - Blue lamp indicates whether the electric contact with BRAVO is established
③ - Green lamp indicates the current state of charge of the battery which is inside
BRAVO
④ - Indentation intended for the storage of the measuring tip
⑤ - Indentation intended for the storage of the reference sample or a vial
⑥ - Compartment for the spare battery (for storing and recharging the spare battery)
⑦ - Ethernet port for connecting the data cable in case the instrument is
connected to a wired network
⑧ - Low-voltage socket for connecting the low-voltage cable to establish the
power supply
⑨ - USB port for connecting an USB stick
Bruker Optik GmbH
BRAVO Analyzer - User Manual
25
D
ra
ft
ve
rs
io
BRAVO analyzer - Overview 3
26
BRAVO Analyzer - User Manual
Bruker Optik GmbH
4
Operation
4.1
This manual is restricted mainly to the hardware-related aspects of operation. For
detailed information about the software-related aspects of operating BRAVO, refer to the
BRAVO Software Manual.
Switching on / off BRAVO
1. Switching on BRAVO
rs
io
Press the ON / OFF button
BRAVO starts to boot up. The boot-up
process takes approx. 10 seconds.
ve
➣
2. Waiting for BRAVO to boot up
Wait until the boot-up process is finished and
the Login screen is displayed on the touchscreen.
ra
ft
☞
in the switched-on state, there is typically a slightly increased heat dissipation at the bottom side of the BRAVO analyzer.
Bruker Optik GmbH
For information about how to log in, see
the following section 4.2.
1. Switching off BRAVO
Press the ON / OFF button
➣
This action switches off the handheld
Raman spectrometer BRAVO. The laser
LED turns off as well.
It is recommended to switch off BRAVO when it is not in use for a longer period of time in
order to prevent the rechargeable battery from discharging unnecessarily.
BRAVO Analyzer - User Manual
27
Operation 4
4.2
Logging in
For your username and password, ask the responsible OPUS administrator.
1. Entering the user name and password
Tap the Username entry field.
➣
The on-screen keyboard pops up.
rs
io
a)
b)
Alternatively, you can scan the user ID,
provided the user name is available as
barcode. In this case, place the user ID
barcode in front of the barcode reader
and press the button
at the BRAVO
button panel.
ve
Enter your user name using the onscreen keyboard.
ra
ft
c)
Tap the Password entry field and enter
your password using the on-screen keyboard.
2. Confirming the entered username and
password
Touch the return key
keyboard.
on the on-screen
➣
The on-screen keyboard disappears and
the start screen of the BRAVO software
program is displayed.
➣
Note: For closing the on-screen keyboard without confirming the entered
data, press the key
➣
After you have logged in, the on-screen
keyboard disappears and the start
screen of the BRAVO software program
is displayed.
To proceed with scanning the barcode of
the sample tap the icon
in the navigation bar.
For information about how to scan the sample barcode, see the following section 4.3.
28
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.3
Scanning the barcode of the sample
1. Positioning the sample barcode in front
of the barcode reader
rs
io
Position the barcode on the sample container
in front of the barcode reader. Make sure that
the barcode reader can scan the complete
barcode.
2. Scanning the barcode
Either press the button
button panel...
at the BRAVO
ve
... or tap the icon
in the navigation bar of
the Scan Barcodes screen.
ra
ft
☞
☞
Alternatively, you can enter the material
name, the batch / lot # and the container #
manually by touching the corresponding
entry field. In doing so, the on-screen keyboard pops up. Enter the data using the
on-screen keyboard. Entering the Material
Name is mandatory, entering Batch / Lot #
and Container # is facultative.
For more details, refer to the BRAVO
Software Manual. This manual is delivered as pdf file on an USB flash drive.
To proceed with verifying the sample,
swipe left in the workflow bar to put the
icon
into the center position.
For information about sample verification, see section 4.5.
BRAVO Analyzer - User Manual
29
Operation 4
4.4
Exchanging the measuring tip
General information
Depending on the type of container in which the sample material is filled, there are two
different types of measuring tips:
Measuring tip for bags
Use this measuring tip for samples
being filled in a plastic bag, in a barrel
etc.
rs
io
➣
Measuring tip for vials
➣
☞
Use this measuring tip for measuring
liquid or solid samples being filled in
a vial.
For additional information about the available measuring tips, see section 3.3.
Exchange procedure
ve
Depending on the type of sample container, install the appropriate measuring tip.
1. Removing a measuring tip
Rotate the bayonet socket ① a quarter
turn. The direction of rotation is indicated
by the red rotation arrow in the left image.
ft
①
ra
②
③
Take off the measuring tip.
2. Installing a measuring tip
Fit the measuring tip on the objective unit
with the groove of the measuring tip ③
being in alignment with the tongue of the
objective unit ②.
Rotate the bayonet socket until it
engages. The direction of rotation is indicated by the red rotation arrow in the left
image.
Note: The bayonet coupling is properly
engaged when the arrow is in line with the
lock icon
30
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.5
Verifying a sample
1. Putting the sample in the measurement
position
In case you verify samples which are filled in
vials, place the vial in the holder of the measuring tip.
rs
io
In case you verify samples which are filled in
bags, press the bag against the laser exit
opening of the measuring tip.
☞
In case the measuring tip needs to be
exchanged, see section 4.4.
2. Enabling the laser (only if not yet done)
Press the button
at the BRAVO button
panel. If the laser is already enabled, skip
this step.
ra
ft
ve
An enabled laser is indicated by a blue
(solid) laser LED.
Note: When you start a measurement with a
disabled laser, BRAVO aborts immediately
the measurement and delivers a result of the
category Aborted. The reason stated for the
abortion is Laser not enabled.
3. Starting the sample measurement
Either press the button
button panel...
at the BRAVO
... or touch the icon
in the navigation bar
of the Collect Data screen.
☞
BRAVO Analyzer - User Manual
For more details, refer to the BRAVO
Software Manual. This manual is delivered as pdf file on an USB flash drive.
31
Operation 4
4. Waiting until the measurement is
finished and the result is displayed on
the touchscreen
Sample measurement in progress
WARNING! LASER EMISSION POSSIBLE!
☞
For detailed information about the laser
exit points and laser safety, refer to
section 1.4.
rs
io
The measurement progress is indicated by a
countdown timer showing the remaining
measurement time.
ve
Note: If additional time is required, a second
countdown timer will appear after the prescan.
ra
ft
①
Important Note: As long as the measurement is in progress, the BRAVO spectrometer emits laser radiation. This is indicated by
a red laser status LED ①. As soon as the
measurement is finished, the laser status
LED returns to blue (solid). This means, the
laser is enabled but it emits no radiation.
Automatic comparison of spectra
Immediately after the data collection, the
BRAVO software compares automatically the
measured sample spectrum with the reference spectra of the used spectra library.
Automatic display of the result
Afterwards, the result of the spectra comparison is displayed automatically. The result categories Accepted and Rejected tell the user
whether the expected material is confirmed
clearly on the basis of the used spectra
library or not.
☞
32
For detailed information about this topic,
refer to the BRAVO Software user manual. This manual is delivered as pdf file
on an USB flash drive.
To proceed with scanning the barcode of
the next sample, touch the icon
in the
navigation bar.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.6
Aborting a running measurement
rs
io
Either Press to Abort on the touchscreen
display or ...
.... press the button
panel.
at the button
ra
ft
ve
Note: Pressing this button disables the
laser and aborts a running measurement.
➣
BRAVO Analyzer - User Manual
In case of a measurement abort, no
data is saved. And consequently,
BRAVO is not able to verify the sample and to deliver a verification result.
Instead, the BRAVO software programme informs the user about the
reason for the abort.
33
Operation 4
4.7
Exchanging the battery
The standard delivery scope includes two rechargeable batteries. One of them serves as
spare part.
Before starting with the battery removal, it is recommended to log out the system and to
switch off BRAVO.
rs
io
1. Opening the battery compartment
Rotate the cover of the battery compartment
counter-clockwise up to the stop.
ve
Take the cover off.
2. Removing the empty battery
ra
①
ft
Pull out the battery.
3. Inserting the charged battery
Insert the battery with the electric contact
strip ① pointing upwards.
Push the battery into the battery compartment.
4. Closing the battery compartment
Insert the two lock hooks at the cover into the
corresponding recesses of the guide slots at
the battery compartment.
Rotate the cover clockwise until it snaps into
place.
34
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.8
Recharging the battery
4.8.1
General information
There are two ways of recharging the battery:
•
by using the batter charger which is included in the standard delivery scope
•
by using the optional docking station
rs
io
Display of the battery state of charge
ve
In case of the battery inside the BRAVO
analyzer, the current battery state of
charge (in precise percentage) is displayed by the BRAVO software in the
upper right corner of the touchscreen display.
The current battery state of charge is
also displayed on the battery itself by a
five-segment bar-graph display ① (in
steps of 20%).
ra
ft
①
Handling instructions
☞
For detailed battery safety instructions, see section 1.6.
NOTICE
To ensure a long service life of the rechargeable battery, observe the
following handling instructions:
➣ Do not expose the battery to high temperatures.
➣ Store the battery in a cool, dry and well-ventilated place.
BRAVO Analyzer - User Manual
35
Operation 4
4.8.2
Recharging the battery with the battery charger
In this case, the battery needs to be removed from the BRAVO analyzer.
☞
For detailed information about how to remove and re-insert the battery, see
section 4.7.
1. Connect the battery charger to the mains
power supply.
rs
io
2. Place the battery into the battery bay of the
charger ensuring that the 5-way connector
is fully seated.
➣
①
The charger will automatically begin
charging the battery.
LEDs ① at the battery charger indicate the
charge state of the battery as follows:
• Green flashing: The battery is charging.
• Green solid: The battery is fully charged.
• Red solid: Error
ve
Battery charger - Safety notes
CAUTION
ft
Non-observance of the following safety instructions may result in minor
or moderate (reversible) injury and minor property damage.
➣ Do not expose the charger or power supply to water or liquids. It is not a sealed
case.
ra
➣ Place the charger in a cool spot, away from external heat sources.
➣ Do not cover the air vent or obstruct the air flow. This will cause overheating.
➣ Do not open the charger or the power supply unit. There are no serviceable parts
inside.
➣ Use only the manufacturer’s power supply and observe the terminal polarity.
36
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.8.3
Recharging the battery via the docking station
With the docking station, two batteries can be charged at the same time: the battery
inside the BRAVO analyzer and the spare battery placed in the battery storage compartment of the docking station.
1.
①
Charging the battery inside BRAVO
2.
Put the BRAVO analyzer with
inserted battery into the docking station as shown in the left image.
3.
Make sure that the blue lamp ② at
the docking station lights. This indicates that the BRAVO analyzer is
properly connected with docking station.
The green lamp ③ at the docking station
indicates the charge state of the battery as
follows:
ve
④
③
rs
io
②
Connect the power cord to both the
docking station ① and the wall
socket.
• The green lamp is flashing. --> The battery is recharging.
ra
ft
• The green lamp lights continuously. -->
The battery is fully recharged.
4.
⑤
As soon as the battery is fully
recharged, you can take BRAVO out
of the docking station and proceed
with your work.
Charging the spare battery
5.
Insert the spare battery into storage
compartment ④ of the docking station.
➣
Note: Insert the battery with the electric contact strip pointing upwards.
The current battery state of charge is displayed on the battery itself by a five-segment bar-graph display ⑤ (in steps of
20%).
To have always a charged battery at hand, make a habit of putting the spare battery into
the battery storage compartment of the docking station.
☞
For more information about the optional docking station, see section 3.6.
BRAVO Analyzer - User Manual
37
Operation 4
4.9
Establishing a wireless connection between BRAVO and a
data station
By default, the BRAVO analyzer is designed for a wireless connection between BRAVO
and data station.
➣
Important Note: For a wireless connection between BRAVO and data station, a
WLAN-capable data station (e.g. notebook, tablet PC) is required. In case there is
no WLAN available at your site, a router is required in addition. In case the data station is not WLAN-capable, a wireless access point is required.
Establishing a wireless connection between BRAVO and the data station involves the
following basic steps:
2.
Connecting the BRAVO analyzer to the WLAN
3.
Connecting the data station to the BRAVO analyzer via WLAN
➣
Important Note: BRAVO and data station have to be connected to the same
WLAN!
➣
Note: The BRAVO analyzer is equipped with a WiFi module which supports the
standards IEEE 802.11b/g/n.
rs
io
Connecting the data station to the WLAN
Connecting the data station to the WLAN
ve
4.9.1
1.
The precise procedure depends on the used wireless LAN-equipment and the wireless
local area network (WLAN) at your site.
For this reason, ask your responsible IT administrator for information about how to
connect your data station to your WLAN.
ra
ft
☞
38
1.
Activate the WLAN card which is
integrated in your data station.
☞
For information about this subject,
refer to the user manual of the data
station in question.
Note: In case a router is used, switch it
on as well.
☞
For information about this subject,
refer to the user manual of the router
in question.
2.
Connect the data station to a WLAN
which is available at your site (e.g. a
company-internal WLAN). Wait until
the wireless connection is established.
☞
If you have any questions on this
subject, contact your IT administrator.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.9.2
Connecting BRAVO to the WLAN
Opening the Settings workflow
1.
Open the Settings workflow by swiping left or right in the navigation bar
until the icon
is in the center.
2.
Touch the icon
rs
io
Opening the Network screen
ve
3.
Swipe left or right in the navigation
bar until the icon
is in the center.
Selecting the network type Wireless
Touch the Wireless Network icon
ra
ft
4.
Performing a WiFi scan to find out
which WLANs are available at your
site.
5.
Touch the WiFi Scan icon
➣
Wait until the WiFi scan is finished.
Afterwards, all WLANs which are
currently available at your site are
displayed.
BRAVO Analyzer - User Manual
39
Operation 4
Selecting the desired WiFi network.
6.
Touch the corresponding option button.
➣
Important: The BRAVO analyzer
and the data station have to be connected to the same WLAN!
Configuring the WiFi network
In case you have selected the option
Select Network Manually, you have
to configure the WiFi network you
intend to use. Enter the Network
Name (SSID) using the on-screen
keyboard.
rs
io
7.
In case you have selected a password-protected network, enter the
password using the on-screen keyboard.
☞
For the network password, ask the
responsible IT administrator.
ve
8.
➣
In case you have selected a nonpassword-protected network, you
can skip this step.
9.
In the navigation bar, Press to Connect.
ra
ft
Establishing the connection between
BRAVO and WLAN
40
10. Wait until the wireless connection is
established.
➣
In case of a successful connection
attempt, the following message
appears: Config. saved. Connection
successful! In addition, the connectivity icon
in the top bar lights
yellow.
☞
In case the connection attempt
failed, see section 7.2.8 for troubleshooting. If you do not succeed in
solving the problem, contact the
responsible IT administrator.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
Connecting the data station to BRAVO via WLAN
1.
Select in the OPUS Measure menu
the Optic Setup and Service function.
2.
Select in the Configuration dropdown list the option BRAVO.
rs
io
4.9.3
Enter the Optical Bench URL of the
BRAVO analyzer to which you want
to connect. The Optical Bench URL
has the following syntax: http://:8443.
➣
Note: You find the IP address ① of
the BRAVO analyzer in the Network
screen of the BRAVO software.
4.
Click on the Connect button.
5.
Exit this dialog by clicking on the
Save Settings button.
①
ra
ft
ve
3.
BRAVO Analyzer - User Manual
41
Operation 4
4.10
Establishing a wired connection between BRAVO and a
data station
4.10.1
General information
Only with the optional docking station, you can establish a wired Ethernet connection
between the BRAVO analyzer and a data station (e.g. PC, notebook) for data transfer
purposes.
The optional docking station is not included in the standard delivery scope. But if
desired, you can reorder a docking station. For the order number, see appendix B,
section B.5.
➣
rs
io
Important Note: For a wired connection between the BRAVO instrument and the
data station, a data station (e.g. PC) with Ethernet port is required.
Note: In case the data station has been delivered by Bruker, the integrated network
interface cards are labelled OPTIC CONNECTOR and LAN. The LAN port has to be
used for the connection between data station and network hub; the OPTIC CONNECTOR port has to be used for the connection between data station and BRAVO analyzer.
Possible connection variants
ve
4.10.2
Basically, the following connection variants are possible:
Connecting the docking station directly to a stand-alone data station
•
Connecting both the docking station and the data station(s) to a local area network
•
Connecting the docking station to a data station which is connected to a local
area network
ft
•
ra
Variant A: Connecting the docking station directly to a stand-alone data station
crossover cable
Port OPTIC
CONNECTOR
IP address: 10.10.0.2
(already factory-assigned if
the PC has been obtained
from Bruker)
IP address: 10.10.0.1
(already factory-assigned)
For establishing this connection variant, one crossover Ethernet cable with RJ45 connector is required.
42
Bruker provides crossover Ethernet cables of different lengths. For the order number,
see appendix B, section B.5.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
Variant B: Connecting the docking station and the data station(s) to a network
Network hub
Straight-through cables
Port LAN
rs
io
Port LAN
All IP addresses have to be defined by your network administrator.
For establishing this connection variant, straight-through Ethernet cables with RJ45 connector are required.
For information about how to assign a network address to BRAVO, see
section 4.10.3.
ft
☞
ve
In case of this connection variant, all IP addresses (i.e. IP addresses for data station(s)
and BRAVO analyzer) have to be defined by your network administrator. To the BRAVO
analyzer, both IP address types - static and dynamic - can be assigned. In the latter
case, however, a DHCP server is required.
ra
Variant C: Connecting the docking station to a network data station
General information
This connection variant requires two network interface cards: one for the communication
between BRAVO and data station and another for the communication between data station and network hub. In case the data station is equipped with only one network interface card, a LAN USB adapter is required for establishing the connection between data
station and network hub.
Bruker provides the required network equipment. For the order number, see appendix B,
section B.6.
For establishing the connection between data station and network hub, a straight
through Ethernet cable with RJ45 connector is required. For establishing the connection
between BRAVO analyzer and data station, a crossover Ethernet cable with RJ45 connector is required.
Bruker provides crossover Ethernet cables of different lengths. For the order number,
see appendix B, section B.5.
BRAVO Analyzer - User Manual
43
Operation 4
Computer equipped with two network cards
Network hub
Straight through cable
Port
LAN
Crossover cable
rs
io
Port OPTIC
CONNECTOR
OPTIC CONNECTOR network card:
IP address: 10.10.0.2
(already factory-assigned if the PC
has been obtained from Bruker)
IP address: 10.10.0.1
(already factory-assigned)
LAN network card:
IP address has to be defined by your
network administrator.
ve
Computer equipped with one network card
Network hub
ft
Straight through cable
ra
LAN USB adapter
USB port
Crossover cable
Network port
Integrated network card:
IP address: 10.10.0.2
(already factory-assigned if the
PC has been obtained from
Bruker)
IP address: 10.10.0.1
(already factory-assigned)
LAN USB adapter:
IP address has to be defined by
your network administrator.
44
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.10.3
Assigning network addresses to BRAVO
General information
The BRAVO analyzer is delivered with the factory-assigned IP address 10.10.0.1. In
case the network connection established at your site requires a different IP address, you
have to assign a different IP address to the BRAVO analyzer. In this case, the IP
address has to be defined by your network administrator.
To the BRAVO analyzer, both IP address types - static and dynamic - can be assigned.
In the latter case, however, a DHCP server is required.
Important note: Only a person with the access right Administrator is authorized to
assign network addresses to the BRAVO analyzer.
Address assignment procedure
rs
io
➣
Opening the Settings workflow
Open the Settings workflow by swiping
left or right in the navigation bar until the
icon
is in the center.
ve
1.
Touch the icon
Opening the Network screen
3.
Swipe left or right in the navigation bar
until the icon
is in the center.
ra
ft
2.
Selecting the network type Wired
4.
BRAVO Analyzer - User Manual
Touch the Wired Network icon
45
Operation 4
5.
Scroll down until the Network Summary
is displayed.
➣
The Network Summary displays the currently assigned network addresses,
namely IP address, subnet mask and
gateway IP.
➣
A static as well as a dynamic address
assignment is possible. Note: For a
dynamic address assignment, a DHCP
server is required.
rs
io
Proceed with either of the two assignment
variant.
Manual assignment of a static IP address
Tap an entry field.
➣
The on-screen keyboard pops up.
7.
Enter the new IP address.
8.
Press the return key
on the onscreen keyboard to confirm the entered
IP address.
➣
The on-screen keyboard disappears.
ve
6.
Note: For closing the on-screen keyboard
without confirming the entered data, press
the key
Dynamic IP address assignment via DHCP
Tap the button Automatic (DHCP).
Note: To deactivate the dynamic address
assignment, tap again the button Automatic
(DHCP).
ra
ft
9.
46
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
4.10.4
Connecting BRAVO to data station
4.10.5
rs
io
In the toolbar, press the network icon to
establish the connection.
Checking the connection between BRAVO and data station
ve
To find out whether there is a communication connection between the BRAVO analyzer
and the data station, proceed as follows:
Select in the OPUS Measure menu
the Device Manager function.
ra
ft
1.
On the Device Manager page General
Settings you see the serial number of the
BRAVO analyzer to which the data station is currently connected.
In case there are no version information
and device information displayed, this
means that the data station is not connected to a BRAVO analyzer at all.
BRAVO Analyzer - User Manual
47
Operation 4
4.11
Mounting / demounting the carrying strap
4.11.1
General information
BRAVO is delivered with the carrying strap not being mounted. The carrying strap can
be mounted on either side of the BRAVO analyzer.
We recommend the usage of the carrying strap. It facilitates carrying and holding the
BRAVO analyzer and provides for a more secure hold of the BRAVO analyzer.
rs
io
The delivery scope includes the following items:
1x carrying strap
ve
2x mounting elements
2x slotted pan head screws ((M2x6)
ra
Procedure
4.11.2
ft
1x flat tip screwdriver
①
1.
48
Remove the two covering caps ①
using the flat tip screwdriver.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Operation 4
2.
Put the slotted head screw in the
mounting element and ...
... screw the mounting element tight
at the BRAVO analyzer.
Note: Attach the mounting element
with the hole pointing upwards.
rs
io
➣
Remove the screw from the swivel
plug at the end of the carrying strap.
ve
3.
Attach the carrying strap by fitting
the swivel plug on the mounting element and tightening the screw you
have removed before.
5.
Attach the other end of the carrying
strap at the BRAVO analyzer in the
same way.
ra
ft
4.
BRAVO Analyzer - User Manual
49
D
ra
ft
ve
rs
io
Operation 4
50
BRAVO Analyzer - User Manual
Bruker Optik GmbH
5
Cleaning and Decontamination
5.1
Cleaning the BRAVO analyzer
5.1.1
Cleaning the plastic cover
rs
io
Wipe the plastic housing clean with a dry or damp cloth. Damp the cloth with water, if
required.
NOTICE
BRAVO analyzer damage because of improper cleaning
➣ Do not immerse the BRAVO analyzer in water or any other liquid cleaning agent.
➣ Do not wash down the BRAVO analyzer.
Cleaning the touchscreen
ve
5.1.2
Cleaning utensils
•
ethanol
Do not use any organic solvent or detergent other than ethanol.
For cleaning the touchscreen, we recommend using a microfiber cloth.
ra
a soft and lint-free cloth
ft
➣
•
Cleaning procedure
Wipe off the touchscreen gently with a soft cloth moistened with ethanol. Do not rub and
do not press too hard on the screen.
We recommend switching off the BRAVO analyzer before beginning to clean the touchscreen. Usually it is much easier to see where the fingerprints and other smudges are
when the BRAVO analyzer is switched off.
NOTICE
BRAVO analyzer damage because of improper touchscreen cleaning
➣ Do not clean the touchscreen with something that is abrasive. Otherwise, there is
the risk of scratching the touchscreen.
➣ Do not spray or pour ethanol directly onto the touchscreen. There is a risk of liquid
leaking into the BRAVO analyzer and damaging it. Instead, moistened the cloth
with ethanol and wipe the touchscreen with the damp cloth.
Bruker Optik GmbH
BRAVO Analyzer - User Manual
51
Cleaning and Decontamination 5
5.2
Decontaminating the BRAVO analyzer
5.2.1
Approved decontaminating agents
The following detergents are approved for decontaminating the BRAVO analyzer:
•
Isopropanol (C3H8O 70%)
•
Sodium hydroxide (NaOH 5%)
•
Sodium hypochlorite (NaClO 6%)
•
Hydrogen peroxide (H2O2 5%)
Decontamination procedure
rs
io
•
1.
Damp a cloth with an appropriate decontaminating agent. Use only an approved
decontaminating agent. (See the above list.)
2.
Wipe off the BRAVO analyzer thoroughly.
3.
Strictly observe the application time of the decontaminating agent in question.
(Note: The correct application is stated by manufacturer of the decontaminating
agent.)
4.
Afterwards, remove the decontaminating agent by wiping off the BRAVO analyzer
thoroughly with a damp cloth (i.e. damped with water).
ve
5.2.2
Ethanol (C2H6O 70%)
NOTICE
ft
BRAVO analyzer damage because of improper decontamination method
ra
➣ Use only an approved decontaminating agent. See the above list. (Note: Only for
the above listed detergents, the material compatibility has been tested.)
➣ Do not immerse the BRAVO analyzer into the liquid decontaminating agent.
➣ Do not wash down the BRAVO analyzer.
52
BRAVO Analyzer - User Manual
Bruker Optik GmbH
6
Repair
6.1
General information
➣
Only Bruker service personnel is authorized to repair the BRAVO analyzer!
WARNING
rs
io
Health hazard because of an unauthorized repair attempt by the user
➣ Do not attempt to repair the BRAVO analyzer. Otherwise there is a potential
health hazard (e.g. exposure tho hazardous laser radiation). Instead, proceed as
described in the following section 6.2.
If your BRAVO analyzer is in need of repair, contact the Bruker service. For repair purposes, the BRAVO analyzer needs to be returned to Bruker.
6.2
For the Bruker service contact data, see section 1.10. For a complete list with the
addresses and telephone numbers of all Bruker headquarters, branch offices and
representations worldwide, visit our website www.brukeroptics.com.
Procedure
ve
☞
In case your BRAVO analyzer is in need of repair, proceed as follows:
Contact the Bruker service and notify us the problem.
2.
Then, Bruker will send you a repair request form (RMA form).
3.
Fill in this form completely and truthfully.
ra
ft
1.
Clean the BRAVO analyzer thoroughly. In case you have analyzed substances
which are dangerous to health you have to decontaminate the BRAVO analyzer
completely before you return it to Bruker.
➣
Note that you have to confirm with the RMA form that the returned BRAVO analyzer
is free of any hazardous material (e.g. infectious, radioactive, toxic or corrosive
material).
4.
Important note: You have to ensure that the returned analyzer is completely free of
any hazardous material so that no person involved in repairing the BARVO analyzer will suffer temporary or permanent damage to their health. You assume full
responsibility if we determine a health risk caused by hazardous substances on
your BRAVO analyzer.
☞
For detailed information about how to clean and decontaminate the BRAVO analyzer, see chapter 5.
5.
Return the RMA form together with the cleaned BRAVO analyzer to Bruker.
BRAVO Analyzer - User Manual
53
D
ra
ft
ve
rs
io
Repair 6
54
BRAVO Analyzer - User Manual
Bruker Optik GmbH
7
Troubleshooting
7.1
General information
rs
io
This chapter deals with the most common problems that may occur as experience has
shown. It provides information about possible causes of the problem and presents solutions for troubleshooting. If the solutions listed in this chapter do not solve the problem,
contact the Bruker service.
☞ For the Bruker service contact data, see section 1.10.
7.2
Problem - possible cause - solution
7.2.1
BRAVO does not boot up
After being switched on, BRAVO does not boot up.
Empty battery
Solutions
ve
Possible causes
Substitute the empty battery for a charged
battery.
☞ See section 4.7.
ft
Recharge the empty battery.
☞ See section 4.8.
ra
No battery is inserted in the BRAVO
analyzer.
A failed BRAVO software update
A defective partition on the SD card
A major BRAVO defect (e.g. damaged
touchscreen)
Insert a charged battery.
☞ See section 4.7.
Recover the system by pressing the ON/
OFF button and the laser enabling /
disabling button simultaneously.
Contact the Bruker service.
☞ For the service contact data, see
section 1.10. For detailed information
about the repair procedure, see
section 6.2.
BRAVO Analyzer - User Manual
55
Troubleshooting 7
7.2.2
Log in attempt failed
Possible causes
Solutions
You have entered the wrong username
and / or the wrong password.
Enter the correct username and / or password.
☞
Your user record has not yet been
transferred form the data station to the
BRAVO analyzer.
Barcode cannot be scanned
Possible causes
Contact the responsible administrator.
Solutions
ft
The distance between the barcode
label and the barcode scanner is too
short or too long.
ra
The window in front of the barcode
scanner is dirty, scratched or damaged.
Barcode label is dirty or damaged.
56
Contact the responsible administrator.
ve
7.2.3
the
rs
io
The administrator has locked your user
record in OPUS.
For your login-data, contact
responsible administrator.
Hold the BRAVO analyzer in such a way
that the barcode label is within the depth of
field range.
☞
For information about the depth of field
range, see section A.6.1
In case of a dirty barcode scanner window,
clean it.
In case of a scratched or damaged barcode
scanner window, contact the Bruker service.
☞ For the service contact data, see
section 1.10. For detailed information
about the repair procedure, see
section 6.2.
In case of a dirty barcode label, clean it
carefully without damaging it.
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Troubleshooting 7
Black touchscreen display
7.2.5
Possible causes
Solutions
After a certain period of time without
any user interaction, the touchscreen
display switches automatically in the
power-saving mode, i.e. it becomes
black.
Touch the touchscreen at any spot.
Failed PQ test / OQ test
Possible causes
rs
io
7.2.4
Solutions
Repeat the test with the correct reference
standard.
The test has been performed with no
reference standard being placed in the
vial holder of the measuring tip.
Repeat the test with the correct reference
standard being placed in the vial holder of
the measuring tip.
Sapphire window is dirty.
Clean it. Afterwards, repeat the test.
Hardware problems
Contact the Bruker service.
☞ For the service contact data, see
section 1.10. For detailed information
about the repair procedure, see
section 6.2.
Aborted measurement
7.2.6
ra
ft
ve
Wrong reference standard has been
used.
Bruker Optik GmbH
Possible causes
Solutions
The spectroscopic measurement has
been started with a disabled laser.
Enable the laser. Then restart the measurement.
☞ For information about how to enable
the laser, see section 1.4.5.
BRAVO Analyzer - User Manual
57
Troubleshooting 7
7.2.7
Problems regarding the detected spectral signal
These kinds of problems become apparent as follows, for example:
•
No spectrum has been acquired.
•
The spectral intensity of the spectrum is too weak.
•
Unexpected spectrum has been acquired.
Solutions
No sample in the sample position during the measurement.
Put the sample in the measurement position and repeat the measurement.
rs
io
Possible causes
Note: In case you verify samples which are
filled in vials, place the vial in the holder of
the measuring tip. In case you verify samples which are filled in bags, press the bag
against the laser exit opening of the measuring tip.
Entrapped air in the vial i.e. entrapped
air between vial and sample powder.
When inserting the vial in the vial holder,
make sure that the label on the vial is not in
the beampath of the laser beam.
ve
The barcode label on the vial or bag
prevents the laser beam from reaching
the sample.
Shake the vial to remove the air inclusions.
Problems regarding wireless data transfer
7.2.8
ra
ft
When pressing the bag against the laser
exit opening of the measuring tip, make
sure that the exiting laser beam will impinge
on the sample and not on the label.
Possible causes
Solutions
Interferences of the WiFi network
caused by microwaves etc.
Eliminate the source of interference.
WiFi signal strength is to weak at your
current location.
Move to a different location where the WiFi
signal strength is higher.
If the above listed solutions do not solve the
problem, contact your administrator who is
responsible for the wireless network at your
site.
58
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Troubleshooting 7
7.2.9
Problems regarding the docking station
You have put the BRAVO analyzer into docking station, but the blue lamp at the docking
station does not light up.
Solutions
You have not put the BRAVO analyzer
properly into docking station.
Put the BRAVO analyzer again into the
docking station. Pay attention to the correct
sit of the contacts.
The corresponding contacts are dirty.
Remove the dirt.
rs
io
Possible causes
For the location of the contact bars,
see section 3.1 and section 3.6.
ra
ft
ve
☞
Bruker Optik GmbH
BRAVO Analyzer - User Manual
59
D
ra
ft
ve
rs
io
Troubleshooting 7
60
BRAVO Analyzer - User Manual
Bruker Optik GmbH
A
Specification
A.1
BRAVO
Parameter
Specified Parameter Value
Dimensions
27.0 cm (w) x 15.6 cm (d) x 6.2 cm (h)
ca. 1.5 kg (3.25 lbs)
Voltage
100 to 240 VAC, 50/60 Hz (for battery charger of the docking station)
rs
io
Weight
Spectral range
3.200 to 250 cm-1
Spectral
resolution
10 cm-1 to 12 cm-1
Laser class
The BRAVO analyzer is classified as a laser class 1M
product according to IEC/EN 60825-1:2007.
ve
Popt < 100mW @ λ = 700 - 1100nm
Laser
Note: The two integrated laser diodes are classified as
laser class 3B lasers.
Detector
Environmental conditions
A.2
High resolution touchscreen (15.0 cm x 9.4 cm),
7" back-lit IPS HD display
Resolution: 1280 x 800 (219ppi)
Viewing angle: 178 °
ra
ft
Touchscreen display
CCD
BRAVO is intended for indoor usage only, namely in laboratory and warehouse environments.
Parameter
Specified Parameter Value
Operating site
BRAVO is intended for indoor usage only, namely in laboratory and warehouse environments.
≤ 2000 above sea level
Ambient temperature
range
5°C to 35°C (41°F to 95 °F)
Atmospheric humidity
(non condensing)
0 to 95% (relative humidity)
Ingress protection
Bruker Optik GmbH
IP 64
BRAVO Analyzer - User Manual
61
Specification A
A.3
Battery and battery charger
A.3.1
Battery
Parameter
Specified Parameter Value
Recharge time for a full
charge
(from 0% to 100%)
3.5 hours
Vmax = 8.4 V
Vnom = 7.2 V
Vcutoff = 4.8 V
rs
io
Voltage
Max. current discharge
3A continuous
Max continuous power
14.4 W (to cutoff voltage)
Battery chemistry
Battery charger
Parameter
ve
A.3.2
Lithium Ion
Specified Parameter Value
Input voltage range
100 - 240 VAC ± 10%, 50/60 Hz
Dimension
Parameter
235 g
Specified Parameter Value
Input voltage range
100 - 240 VAC ± 10%, 50/60 Hz
Power consumption
2.5 A max.
Dimension
Weight
62
180 mm (length) x 92 mm (width) x 58 mm (height)
Docking Station
A.4
ra
Weight
1.5 A max.
ft
Power consumption
36 cm x 15 cm x 13 cm
ca. 1.9 kg (4.2 lbs)
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Specification A
A.5
WiFi module
The BRAVO analyzer is equipped with a WiFi module which supports the standards
IEEE 802.11b/g/n.
This WiFi module has an approval certificate for the U.S. and Canada.
FCC ID: 2AD88-BRAVO-01
approval certificate for Canada
IC: 5969A-TIWI101
A.6
Barcode reader
A.6.1
Depth of field range
Depth of field - Typical range
100% U.P.C.
46 mm to 419 mm (1.8’’ to 16.5’’)
5 mil Code 39
64 mm to 163 mm (2.5’’ to 6.4’’)
10 mil Code 39
28 mm to 338 mm (1.1’’ to 13.3’’)
10 mil Data Matrix
46 mm to 185 mm (1.8’’ to 7.3’’)
53 mm to 203 mm (2.1’’ to 8.0’’)
ft
Resolution
ve
Symbology
6.7 mil PDF417
A.6.2
rs
io
approval certificate for the U.S.
ra
Type of barcode
Resolution
0.127 mm (5.0 mil)
2D matrix code
0.169 mm (6.7 mil)
linear barcode
BRAVO Analyzer - User Manual
63
D
ra
ft
ve
rs
io
Specification A
64
BRAVO Analyzer - User Manual
Bruker Optik GmbH
B
Orderable items
B.1
Spare parts & replacement parts
Order number
Single battery charger
C612
Rechargeable battery
7.2 V (< 100 Wh), initial operating time > 4h
R420
Measuring tip for bags
R421
Measuring tip for vials
S152
Strap for carrying / holding the BRAVO analyzer
1826953
Battery compartment cover
(replacement part for the battery compartment cover included
in the standard delivery scope)
ve
rs
io
C610
S150
Carrying case for the BRAVO analyzer
(replacement part for the carrying case included in the standard delivery scope of the BRAVO analyzer)
Storage case for the docking station
(replacement part for the storage case included in the delivery
scope of the optional docking station)
ft
S151
Reference standards and certified samples
ra
B.2
Item
Order number
Item
BRM400
Polystyrene rod (reference sample for performing the PQ test)
BRM420
Validation Kit
(for validating BRAVO in accordance USP35, Ph.Eur. 7.0,
ASTM E1840-96,ASTM E2529-06 and ASTM E2911-13)
The validation kit includes the following Raman reference standards:
• 1x vial with cyclohexane
• 1x vial with naphthalene
• 1x vial with benzonitrile
• 1x vial with tylenol
• 1x PE bag with tylenol
For each Raman reference standard, the certificate of origin is
included.
Bruker Optik GmbH
BRAVO Analyzer - User Manual
65
Orderable items B
Order number
BRM421
Raman standard cyclohexane with certificate of origin
for validation with measuring tip for vials
BRM422
Raman standard naphthalene with certificate of origin
for validation with measuring tip for vials
BRM423
Raman standard benzonitrile in vial with certificate of origin
for validation with measuring tip for vials
BRM424
Raman standard tylenol in vial with certificate of origin
for validation with measuring tip for vials
BRM425
Raman standard tylenol in PE bag with certificate of origin
for validation with measuring tip for bags
rs
io
B.3
Item
Consumables
200x glass vials including stoppers
Recommended: S154 - septa for stoppers
S154
septa for stoppers in S153
ft
S153
Cleaning utensils
ra
B.4
Item
ve
Order number
Order number
1828002
B.5
Item
1x microfiber tissue for cleaning the touchscreen display
(especially for removing fingermarks)
Optional parts
Order number
S201
Item
Docking station
The delivery scope includes:
• docking station
• power supply unit and power cord
• storage case
66
BRAVO Analyzer - User Manual
Bruker Optik GmbH
Orderable items B
B.6
Network equipment
Order number
Item
C295-E
USB-LAN adapter
C295-PCIE
Network interface card (for PC model HP Elite 800 G1 Tower,
800 G1-Ultra Slim)
10/100/1000 Mbit, RJ45, PCle-interface
rs
io
For establishing a direct Ethernet connection between the docking station and the data
station (e.g. PC, notebook), a crossover cable with RJ 45 connector is required. This
type of cable is available in the following lengths:
Order number
Item
Ethernet cable (crossover) with RJ 45
cable length: 10 m
I24010
Ethernet cable (crossover) with RJ 45
cable length: 30 m
I24011
Ethernet cable (crossover) with RJ 45
cable length: 50 m
ve
I21329
Ethernet cable (crossover) with RJ 45
cable length: 100 m
ra
ft
I24012
Bruker Optik GmbH
BRAVO Analyzer - User Manual
67
D
ra
ft
ve
rs
io
Orderable items B
68
BRAVO Analyzer - User Manual
Bruker Optik GmbH
rs
io
ve
ft
ra
Bruker Optik GmbH
BRAVO Analyzer - User Manual
69
rs
io
ve
ft
ra
70
BRAVO Analyzer - User Manual
Bruker Optik GmbH

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : mafe
Create Date                     : 2015:06:25 13:18:34Z
Modify Date                     : 2015:06:25 14:16:12-04:00
Has XFA                         : No
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Creator Tool                    : FrameMaker 10.0.2
Metadata Date                   : 2015:06:25 14:16:12-04:00
Format                          : application/pdf
Title                           : BRAVO Analyzer_EN.book
Creator                         : mafe
Document ID                     : uuid:04b4bf6b-8710-415d-9c48-26d53f4cefd2
Instance ID                     : uuid:0fb28638-3ce7-4488-95cd-e0493181b126
Page Mode                       : UseOutlines
Page Count                      : 72
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AD88-BRAVO-01

Navigation menu