ELECTRIC
AIR CONDITIONER

Model 593C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable
cooling performance. Built into these units are the features most desired by homeowners today. Standard
SEER ratings of 10.0 can reach as high as 11.2 when
combined with specific Bryant equipment. All models
are listed with ARI, UL (U.S. and Canada), and CEC.
AVAILABLE OPTIONS
ELECTRICAL RANGE—All units are offered in 208–
230v single phase.
WIDE RANGE OF SIZES—Available in 7 nominal
sizes from 018 through 060 to meet the needs of residential and light commercial applications.

Model 593C (60 Hz)
Sizes 018 thru 060

WEATHER-PROTECTIVE CABINET—Steel is galvanized and
coated with a layer of zinc phosphate. A coat of modified polyester powder coating is then applied and baked-on, providing
each unit with a hard, smooth finish that will last for many years.
All screws on cabinet exterior are ceramic coated for a longlasting, rust-resistant, quality appearance.
HEAVY DUTY INLET GRILLE—The DuraGuard™ coil protector, made of a coated steel wire grid with vertical 3/8 in. spacing,
is designed to help protect the coil from inclement weather, vandalism, and incidental damage. It provides protection while not
restricting airflow and maintaining ease of coil inspection and
cleaning.
TOTALLY ENCLOSED FAN MOTOR—Means greater reliability
under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type
motor was designed for optimum efficiency. Then the motor was
tested and qualified under extreme conditions to help ensure
the greatest reliability.
UNIT DESIGN—Copper tube, enhanced aluminum fin coil is
designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent
patio areas and foliage. Heat pump-style drain pan for easy
removal of water, dirt, and leaves.
BRYANT’S AEROQUIET SYSTEM—Extremely low operating
sound is the result of special attention to the air moving through
the outdoor unit, and a specially designed sound enclosure surrounding the compressor to eliminate sound transmission to the
rest of the systems.
APPLICATION VERSATILITY—The 593C can be combined
with a wide variety of evaporator coils and blower packages to
provide quiet, dependable comfort. Unit can be installed on a
roof or at ground level on a slab.
EXTERNAL SERVICE VALVES—Both service valves are
brass, front seating type with sweat connections. Valves are
externally located so refrigerant tube connections can be made
quickly and easily. Each valve has a service port for ease of
checking operating refrigerant pressures.
EASY SERVICEABILITY—One access panel provides access
to electrical controls and compressor. Removal of wire dome
gives access to fan motor and removal of the top gives access
to the coil. For improved serviceability, all models are equipped
with a compressor terminal plug.
COMPRESSOR PROTECTION—Each model is protected with
internal temperature- and current-sensitive overloads. An internal pressure relief valve provides high-pressure protection to
the refrigerant system.
LIMITED WARRANTY—Standard 5-year warranty on all parts,
with an additional 10-year warranty on compressor.

Form No. PDS 593C.18.7

—2—

UNIT
SIZE
018
024
030
036
042
048
060

SERIES
C, D
C, D
C, D
C, D
C, D
C
C

AIR DISCHARGE

AIR IN

AIR DISCHARGE

AIR IN

AIR IN

A
23-13/16
23-13/16
27-13/16
33-13/16
27-13/16
33-13/16
39-13/16

L

B
22-1/2
22-1/2
22-1/2
22-1/2
30
30
30

J

NOTES:

E

N

1 9/16"

2 1/2"

1 3/4"

4

3/16"

10 1/2"

3/8" DIA. LIQUID
LINE CONN.

H DIA. VAPOR
LINE CONN.

FIELD CONTROL
SUPPLY CONN
7/8" DIA. HOLE

F

G

A

D
4-1/8
4-1/8
4-1/8
4-1/8
5-1/16
5-1/16
5-1/16

E
7-1/8
7-1/8
7-1/8
7-1/8
9-11/16
9-11/16
9-11/16

UNIT DIMENSIONS
F
G
13-13/16
18-3/8
13-13/16
18-3/8
15-15/16
22-3/8
21-15/16
28-3/8
15-15/16
22-3/8
21-15/16
22-3/8
27-15/16
34-3/8

H
5/8
5/8
3/4
3/4
7/8
7/8
7/8

DIMENSIONS (IN.)
K
12-1/2
12-1/2
12-1/2
12-1/2
16-1/2
15-1/2
15-1/2

L
15-1/2
15-1/2
15-1/2
15-1/2
20-3/8
18
18

M
10-1/2
10-1/2
11-1/2
13
12-5/16
13-1/2
16-1/2

M

N
2-3/8
2-3/8
2-3/8
2-3/8
2-15/16
2-15/16
2-15/16

1 1/4"

FIELD POWER SUPPLY CONN. 7/8" DIA.
HOLE WITH 1 1/8" DIA. KNOCKOUT
AND 1 3/8" DIA. KNOCKOUT

1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE
SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW.
2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 55°F,
(UNLESS LOW AMBIENT CONTROL IS USED) MAX. 125°F.
3. SERIES DESIGNATION IS THE 14TH POSITION OF THE UNIT MODEL NUMBER.
4. CENTER OF GRAVITY .

C
26-3/16
26-3/16
26-3/16
26-3/16
33
33
33

C
L

D

K

C
AIR DISCHARGE

DIA. TIEDOWN KNOCKOUTS
(2) PLACES

3/8"

A99067

MINIMUM MOUNTING
PAD DIMENSIONS
22 x 26
22 x 26
22 x 26
22 x 26
28 x 31
28 x 31
28 x 31

ACCESS
PANEL

B

RECOMMENDED TUBE DIAMETERS
UNIT
SIZE
018, 024
030, 036
042, 048
060

LIQUID TUBE DIAMETER (IN.)
0 to 50 Ft
Tube Length
Long-Line Applications*

3/8

3/8

VAPOR TUBE DIAMETER (IN.)
0 to 50 Ft
Long-Line Applications*
Tube Length
(Maximum Diameter)
5/8
3/4
3/4
7/8
7/8
1-1/8
1-1/8
1-1/8

* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.

CHECK-FLO-RATER® PISTON
PISTON*
IDENTIFICATION NO.
55
57
67
73
78
82
96

UNIT SIZE—SERIES
018-C, D
024-C, D
030-C, D
036-C, D
042-C, D
048-C
060-C

A

AIR
CO

Y

NING
ITIO
ND

UNIT
AR

T
IFIED O ARI A
RT
S
C
CE

EQ

RI

YING WITH
PL
OM

MANUFACTUR
ER

* Piston listed is for any approved non-capillary tube coil combination. Piston is
shipped with outdoor unit and must be installed in an approved indoor coil.

UIP M E NT

STA

NDARD

21

0

CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.

REGISTERED QUALITY SYSTEM

—3—

SPECIFICATIONS
UNIT SIZE
Operating Weight (Lb)
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor— Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (75°C Copper) AWG†
Min Wire Size (60°C Copper) AWG†
Max Wire Length (Ft) (75°C Copper)‡
Max Wire Length (Ft) (60°C Copper)‡
Max Branch Circuit Fuse Size**
COMPRESSOR and REFRIGERANT
Compressor—Manufacturer and Type
Temperature and Current Protection
Refrigerant—Type and Amount (Lb)††
CONDENSER COIL and FAN
Coil Face (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP, Type, and RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet
Coastal Filter
Time Delay Relay
Cycle Protector
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
Sound Hood
TXV Kit (RPB)
TXV Kits (Hard Shutoff)
Low-Pressure Switch
High-Pressure Switch
Filter Drier
Evaporator Freeze Thermostat**
Liquid-Line Solenoid Valve
Winter Start Control**
Low-Ambient Kit
MotorMaster® Control††
Ball Bearing Fan Motor
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Builder’s Thermostat, Manual
Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Thermidistat™ Control—Programmable/
Non-Programmable Thermostat with
Humidity Control
Outdoor Air Temperature Sensor
Backplate for Non-Programmable
Thermostat
Backplate for Programmable Thermostat
Backplate for Builder’s Thermostat
Thermostat Conversion Kit (4 to 5 wire)
— 10 Pack

018-C, D
137

024-C, D
143

030-C, D
161

036-C, D
169

13.7
75.0
0.8
17.9
14
14
42
44
25

15.0
82.0
1.4
20.2
12
12
57
60
30

208–230—60—1
197—253
8.6
49.0
0.5
11.3
14
14
62
66
15

R-22 and 3.88

10.9
56.0
0.5
14.1
14
14
50
53
20

Copeland Reciprocating
Internal Line Break
R-22 and 4.44
R-22 and 4.63

7.2
7.2
20—1—1
25—1—1
1/12 PSC and 1100
1900

1900

8.8
25—1—2
1/10 PSC and 1100
208/230—60—1
2100

R-22 and 5.50
10.9
25—1—2
1/4 PSC and 1100
2600

KSASF0101AAA
KAACF0701SML
KAATD0601TDR
KSACY0101AAA
KAACH1001AAA
KSAHS1001AAA
KAACS0201PTC
KSASH1101COP
KSASH1201COP
KAATX0201RPB
KAATX0301RPB
KAATX0401RPB
KAATX0501RPB
KSATX0601HSO
KAALP0101LPS
KSAHI0101HPS
P502-8083S (RCD)
KAAFT0101AAA
KAALS0101LLS
KAAWS0101AAA
KSALA0201R22
32LT660004 (RCD)
HC34GE232 (RCD)

TSTATBBNAC01-B

TSTATBBPAC01-B

TSTATBBBAC01-B

TSTATBBPRH01-B
TSTATBBSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXCNV10

See notes on page 5.

—4—

SPECIFICATIONS Continued
UNIT SIZE
Operating Weight (Lb)
ELECTRICAL
Unit Volts—Hertz—Phase
Operating Voltage Range*
Compressor— Rated Load Amps
Locked Rotor Amps
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (75°C Copper) AWG†
Min Wire Size (60°C Copper) AWG†
Max Wire Length (Ft) (75°C Copper)‡
Max Wire Length (Ft) (60°C Copper)‡
Max Branch Circuit Fuse Size**
COMPRESSOR and REFRIGERANT
Compressor—Manufacturer and Type
Temperature and Current Protection
Refrigerant—Type and Amount (Lb)††
CONDENSER COIL and FAN
Coil Face (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP, Type, and RPM
Volts—Hertz—Phase
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet
Coastal Filter
Time Delay Relay
Cycle Protector
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
Sound Hood
TXV Kit (RPB)
TXV Kits (Hard Shutoff)
Low-Pressure Switch
High-Pressure Switch
Filter Drier
Evaporator Freeze Thermostat**
Liquid-Line Solenoid Valve
Winter Start Control**
Low-Ambient Kit
MotorMaster® Control††
Ball Bearing Fan Motor
Thermostat, Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat, Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Builder’s Thermostat, Manual
Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Thermidistat™ Control—Programmable/
Non-Programmable Thermostat with
Humidity Control
Outdoor Air Temperature Sensor
Backplate for Non-Programmable
Thermostat
Backplate for Programmable Thermostat
Backplate for Builder’s Thermostat
Thermostat Conversion Kit (4 to 5 wire)
— 10 Pack

042-C, D
206

048-C
199

060-C
217

19.0
105.0
1.4
25.2
10
10
73
77
40

208–230—60—1
197—253
24.4
140.0
1.4
31.9
10
8
59
97
50

28.8
165.0
1.4
37.4
8
8
78
82
60

Copeland Reciprocating
Internal Line Break
R-22 and 5.51
12.2
20—1—2

Millennium Scroll
Millennium Scroll
Internal Line Break and Dome Thermostat
R-22 and 7.63
R-22 and 10.63
15.2
25—1—3
1/4 PSC and 1100
208/230—60—1
3000

18.3
25—1—4

KSASF0101AAA
KAACF0801MED
KAATD0101TDR
KSACY0101AAA
Standard
KSAHS1301AAA

KAACH1201AAA
KSAHS1601AAA
KAACS0201PTC

KSASH1201COP
KAATX0501RPB
KSATX0601HSO

KSASH2001CYL
KAATX0601RPB

KAATX0701RPB
KSATX0701HSO

KAALP0101LPS
KSAHI0101HPS
P502-8163S (RCD)
KAAFT0101AAA
KAALS0101LLS
KAAWS0101AAA
KSALA0201R22
32LT660004 (RCD)
HC40GE232 (RCD)

TSTATBBNAC01-B

TSTATBBPAC01-B

TSTATBBBAC01-B

TSTATBBPRH01-B
TSTATBBSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXCNV10

* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors per the NEC (ANSI/NFPA 70) Article
336-26. If other than uncoated (non-plated), 60° or 75°C (140° or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for
larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** Fan motor with ball bearings required. See Low-ambient controller Installation Instructions for application.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

—5—

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.
2. Coastal Filter
A filter designed to protect the condenser coil from salt damage without restricting airflow through the outdoor coil.
SUGGESTED USE: Geographic areas prone to salt spray. Used to meet job specifications where added coil protection is required.
3. Compressor Start Assist—Capacitor/Relay Type
Start capacitor and start relay gives ‘‘hard’’ boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.
Installations where outdoor design temperature exceeds 105°F (40.6°C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.
4. Compressor Start Assist—PTC Type
Solid-state electrical device which gives a ‘‘soft’’ boost to compressor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
5. Crankcase Heater
An electric resistance heater which mounts to the base of compressor to keep lubricant warm during off cycles. Improves compressor lubrication on
restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.
When unit will be operated below 55°F (12.8°C) outdoor air temperature. Use with Low-Ambient Controller.
All commercial installations.
6. Cycle Protector
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has
been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
Where user is likely to ‘‘play’’ with the room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 50 ft.
High rise applications.
7. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Low-Ambient Controller has been added.
8. Filter Drier
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.
SUGGESTED USE: All split-system air conditioners.
9. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10
psig and resets at 298 ± 20 psig. Provides additional protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor
recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).
10. Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration), which stops and starts refrigerant
liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
Note: Compressor Start Assist—Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
In certain long line applications. Refer to Long-Line Application Guideline.
11. Low-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Also, provides additional protection against compressor damage due to loss of refrigerant
charge. To prevent rapid compressor recycling. Compressor Cycle Protector can be used with this switch.
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.
All commercial installations.
12. MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ±10°F.
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.
All commercial installations.
13. Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All corporate programmable thermostats.
14. Sound Hood
Wrap-around sound attenuation cover for the compressor. Reduces the sound level by about 2 decibels.
SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.
Unit installed between 2 houses less than 10 ft apart.
15. Support Feet
Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base;
minimizes corrosion.
SUGGESTED USE: Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
16. Thermostatic Expansion Valve (TXV) Kits
A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB type valves are available. Do not use hard shutoff
TXV with Liquid-Line Solenoid Valve.
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning systems.

—6—

ACCESSORY DESCRIPTION AND USE (Listed Alphabetically) Continued
17. Time Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
18. Winter Start Control
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low load
conditions.
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.

ACCESSORY USAGE GUIDELINE

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
MotorMaster® Control
or
Low-Ambient Pressure Switch
Wind Baffle
Coastal Filter
Support Feet
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
Ball Bearing Fan Motor

REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
Yes
Yes
Yes†
No

REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
Yes
No
No
No

REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 Miles)
No
No
No
No

Yes

Yes

No

Yes

No

No

See Low-Ambient Instructions
No
Recommended

No
No
No
See Long-Line
Application
Guideline
No

No
Yes
Recommended

No
Yes‡

No
No

* For tubing line sets greater than 50 ft and/or 20 ft vertical differential, refer to Residential Split-system Long-Line Application Guideline and Service Manual.
† Only when low-pressure switch is used.
‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster® Control only.

SOUND POWER (dBA)
Unit
Size
018-C, D
024-C, D
030-C, D
036-C, D
042-C, D
048-C
060-C

Sound
Level
(dBA)
76
78
80
80
80
82
82

OCTAVE BAND CENTER FREQUENCY (Hz)
125
54.0
53.0
53.5
57.0
62.5
63.0
61.5

250
63.5
69.0
64.0
65.5
69.0
71.0
69.5

500
66.0
69.5
66.5
71.0
72.0
71.0
71.0

—7—

1000
66.0
71.0
69.5
75.0
75.0
72.0
74.5

2000
65.0
68.5
69.0
71.0
72.0
73.5
70.0

4000
62.5
64.5
65.0
67.5
69.5
68.0
69.0

8000
55.5
60.5
58.5
62.0
62.5
63.5
66.0

COMBINATION RATINGS
UNIT
SIZE-SERIES

INDOOR
MODEL
CC5A/CD5AA018*
CC5A/CD5AA024
CC5A/CD5AW024
CE3AA024
CF5AA024
CK3BA024
CK5A/CK5BA018
CK5A/CK5BA024
CK5A/CK5BW024
F(A,B)4(A,B)NF018
F(A,B)4(A,B)NF024
FC4(B,C)NF024
FF1DNA018
FF1DNA024
FG3AA024
FK4(C,D)NF001
FK4(C,D)NF002

018-C, D

CC5A/CD5AA018
CC5A/CD5AA024
CC5A/CD5AW024
CE3AA024
CK3BA024
CK5A/CK5BA018
CK5A/CK5BA024
CK5A/CK5BW024
CD5A/CD5BA018
CC5A/CD5AA018
CK3BA024
CK5A/CK5BW024
CC5A/CD5AA018
CK3BA024
CK5A/CK5BW024
CC5A/CD5AA024*
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
CE3AA030
CF5AA024
CK3BA024
CK3BA030
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
F(A,B)4(A,B)NF024
F(A,B)4(A,B)NF030
FC4(B,C)NF024
FC4(B,C)NF030
FF1DNA024
FF1DNA030
FG3AAA024
FK4(C,D)NF001
FK4(C,D)NF002
FK4(C,D)NF003

024-C, D

CC5A/CD5AA024
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
CE3AA030
CK3BA024
CK3BA030
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
CC5A/CD5AA024
CK3BA024
CK3BA030
CK5A/CK5BW030
CC5A/CD5AA024
CK3BA024
CK3BA030
CK5A/CK5BW024
CK5A/CK5BW030
CC5A/CD5AA024
CK3BA024
CK3BA030
CK5A/CK5BW024
CK5A/CK5BW030

See notes on page 14.

FACTORYBRYANT GAS
TOT.
SUPPLIED
FURNACE OR
CAP.
ENHANCESTANDARD
ACCESSORY
BTUH
MENT
RATING
TDR†
17,200
NONE
10.00
10.50
17,800
NONE
10.50
11.00
17,800
NONE
10.50
11.00
18,000
NONE
10.50
11.00
18,000
NONE
10.50
11.00
17,800
NONE
10.50
11.00
17,200
NONE
10.00
10.50
17,800
NONE
10.50
11.00
17,800
NONE
10.50
11.00
17,000
TDR
10.00
—
18,000
TDR
10.50
—
18,000
TDR & TXV
10.50
—
17,000
TDR
10.00
—
18,000
TDR
10.20
—
17,600
NONE
10.20
10.60
18,000
TDR & TXV
12.00
—
18,000
TDR & TXV
12.00
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
17,200
TDR
11
11
17,600
TDR
11.5
11.5
17,600
TDR
11.5
11.5
17,600
TDR
11.5
11.5
17,600
TDR
11.5
11.5
17,200
TDR
11
11
17,600
TDR
11.5
11.5
17,600
TDR
11.5
11.5
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
17,600
NONE
11.00
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
17,600
NONE
11.00
—
17,600
NONE
11.50
—
17,600
NONE
11.50
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
17,600
NONE
11.00
—
17,600
NONE
11.50
—
17,600
NONE
11.50
—
23,000
NONE
10.00
10.20
23,000
NONE
10.00
10.50
23,000
NONE
10.00
10.20
23,000
NONE
10.10
10.50
23,200
NONE
10.00
10.20
23,400
NONE
10.10
10.50
23,000
NONE
10.10
10.50
23,000
NONE
10.00
10.20
23,000
NONE
10.00
10.50
23,000
NONE
10.00
10.20
23,000
NONE
10.00
10.50
23,000
NONE
10.00
10.20
23,000
NONE
10.00
10.50
23,000
TDR
10.00
—
23,200
TDR
10.20
—
23,000
TDR & TXV
10.00
—
23,400
TDR & TXV
10.20
—
23,000
TDR
10.00
—
23,400
TDR
10.00
—
22,400
NONE
10.00
10.20
24,000
TDR & TXV
11.50
—
24,000
TDR & TXV
11.50
—
24,000
TDR & TXV
11.50
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
22,200
TDR
11
11
22,400
TDR
11
11
22,200
TDR
11
11
22,400
TDR
11
11
22,200
TDR
11
11
22,400
TDR
11
11
22,200
TDR
11
11
22,400
TDR
11
11
22,200
TDR
11
11
22,400
TDR
11
11
22,200
TDR
11
11
22,400
TDR
11
11
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
22,600
NONE
11.00
—
22,600
NONE
11.00
—
23,200
NONE
11.20
—
23,200
NONE
11.20
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
22,600
NONE
11.00
—
22,600
NONE
11.00
—
23,200
NONE
11.20
—
22,600
NONE
11.00
—
23,200
NONE
11.20
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
22,600
NONE
11.00
—
22,600
NONE
11.00
—
23,200
NONE
11.20
—
22,600
NONE
11.00
—
23,200
NONE
11.20
—

—8—

ACCESSORY
TXV‡
10.50
11.00
11.00
11.00
11.00
11.00
10.50
11.00
11.00
10.00
10.50
—
10.50
10.50
10.60
—
—
10.35
10.65
10.65
10.65
10.85
10.6
10.85
10.85
11.00
11.00
11.50
11.50
11.00
11.50
11.50
10.20
10.50
10.20
10.50
10.20
10.50
10.50
10.20
10.50
10.20
10.50
10.20
10.50
10.00
10.20
—
—
10.20
10.20
10.20
—
—
—
9.85
10
9.85
10
9.9
10.05
10
10
10
10
10
10
11.00
11.00
11.20
11.20
11.00
11.00
11.20
11.00
11.20
11.00
11.00
11.20
11.00
11.20

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
CC5A/CD5AA030*
CC5A/CD5AA036
CC5A/CD5AW030
CD5AW036
CE3AA030
CE3AA036
CF5AA036
CK3BA030
CK3BA036
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BN036
CK5A/CK5BW030
CK5A/CK5BW036
F(A,B)4(A,B)NF030
F(A,B)4(A,B)NF036
FC4(B,C)NF030
FC4(B,C)NF036
FD3(A,B)NA030
FF1DNA030
FG3AAA036
FK4(C,D)NF001
FK4(C,D)NF002
FK4(C,D)NF003
FK4(C,D)NF005
CC5A/CD5AA030
CC5A/CD5AA036
CC5A/CD5AW030
CE3AA030
CE3AA036
CK3BA030
CK3BA036
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW030

030-C, D

CC5A/CD5AA030
CC5A/CD5AA036
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
CE3AA036
CK3BA030
CK3BA036
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BW030
CK5A/CK5BW036
CC5A/CD5AA030
CK3BA030
CK3BA036
CK5A/CK5BW030
CK5A/CK5BW036
CC5A/CD5AA030
CK3BA030
CK3BA036
CK5A/CK5BA036
CK5A/CK5BN036
CK5A/CK5BW030
CC5A/CD5AA030
CK3BA030
CK3BA036
CK5A/CK5BW030
CK5A/CK5BW036
CK3BA030
CK3BA036
CK5A/CK5BW030
CK5A/CK5BW036
CC5A/CD5AA030
CK3BA030
CK3BA036
CK5A/CK5BW030
CK5A/CK5BW036
CK3BA030
CK3BA036
CK5A/CK5BW036

See notes on page 14.

FACTORYBRYANT GAS
TOT.
SUPPLIED
FURNACE OR
CAP.
ENHANCESTANDARD
ACCESSORY
BTUH
MENT
RATING
TDR†
28,600
NONE
10.00
10.20
29,000
NONE
10.10
10.50
28,600
NONE
10.00
10.20
29,000
NONE
10.10
10.50
28,400
NONE
10.00
10.20
29,000
NONE
10.10
10.50
29,000
NONE
10.10
10.50
28,600
NONE
10.00
10.20
29,000
NONE
10.10
10.50
28,600
NONE
10.00
10.20
29,000
NONE
10.10
10.50
27,000
NONE
10.10
10.50
28,600
NONE
10.00
10.20
29,000
NONE
10.10
10.50
28,200
TDR
10.00
—
28,800
TDR
10.20
—
28,400
TDR & TXV
10.00
—
28,800
TDR & TXV
10.20
—
28,400
NONE
10.00
—
28,400
TDR
10.00
—
29,000
NONE
10.20
10.50
29,600
TDR & TXV
11.00
—
29,600
TDR & TXV
11.00
—
29,600
TDR & TXV
11.20
—
30,0000
TDR & TXV
11.50
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
28,000
TDR
11
11
28,600
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
28,600
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
28,000
TDR
11
11
29,000
TDR
11
11
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
29,000
NONE
11.00
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
29,000
NONE
11.00
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
27,000
NONE
10.50
—
29,000
NONE
10.50
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
29,000
NONE
11.00
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
29,000
NONE
10.50
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
29,000
NONE
11.00
—
29,000
NONE
10.50
—
29,000
NONE
11.00
—
29,000
NONE
10.50
—
29,000
NONE
11.00
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
29,000
NONE
10.50
—
29,000
NONE
11.00
—
29,000
NONE
11.00
—

—9—

ACCESSORY
TXV‡
10.20
10.50
10.20
10.50
10.20
10.50
10.50
10.20
10.50
10.20
10.50
10.50
10.20
10.50
10.00
10.20
—
—
10.00
10.00
10.50
—
—
—
—
9.75
10.05
9.75
9.85
9.9
9.75
10.05
9.75
10.05
10.05
9.75
9.85
10.15
9.85
10.15
9.95
10.05
9.85
10.15
9.85
10.15
9.85
10.15
11.00
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.00
10.50
11.00
10.50
11.00
10.50
11.00
11.00

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
CC5A/CD5AA036*
CC5A/CD5AA042
CC5A/CD5AW042
CD5AW036
CE3AA036
CE3AA042
CF5AA036
CK3BA036
CK3BA042
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BN036
CK5A/CK5BN042
CK5A/CK5BW036
F(A,B)4(A,B)NF036
F(A,B)4(A,B)N(F,B)042
FC4(B,C)NF036
FC4(B,C)N(F,B)042
FG3AAA036
FK4(C,D)NF001
FK4(C,D)NF002
FK4(C,D)NF003
FK4(C,D)NF005
FK4(C,D)NB006
CC5A/CD5AA036
CE3AA036
CE3AA042
CK3BA036
CK5A/CK5BA036
CK5A/CK5BE042
CK5A/CK5BT036

036-C, D

CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
CE3AA042
CK3BA036
CK3BA042
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
CE3AA042
CK3BA036
CK3BA042
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
CE3AA042
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
CE3AA042
CK3BA042
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036

FACTORYBRYANT GAS
TOT.
SUPPLIED
FURNACE OR
CAP.
ENHANCESTANDARD
ACCESSORY
BTUH
MENT
RATING
TDR†
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,400
NONE
10.00
10.20
34,600
NONE
10.10
10.50
34,600
NONE
10.10
10.50
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
32,000
NONE
10.00
10.20
33,600
NONE
10.00
10.20
34,600
NONE
10.00
10.20
34,000
TDR
10.00
—
34,800
TDR
10.20
—
34,000
TDR & TXV
10.00
—
34,800
TDR & TXV
10.20
—
34,000
NONE
10.00
10.20
34,600
TDR & TXV
10.20
—
34,600
TDR & TXV
10.20
—
34,800
TDR & TXV
10.50
—
35,400
TDR & TXV
11.00
—
35,400
TDR & TXV
11.50
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
33,000
TDR
11
11
32,600
TDR
10.5
10.5
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
32,600
TDR
10.5
10.5
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
32,600
TDR
10.5
10.5
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
32,600
TDR
10.5
10.5
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
32,600
TDR
10.5
10.5
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11
33,000
TDR
11
11

See notes on page 14.

—10—

ACCESSORY
TXV‡
10.20
10.20
10.20
10.20
10.20
10.50
10.50
10.20
10.20
10.20
10.20
10.20
10.20
10.20
10.00
10.20
—
—
10.20
—
—
—
—
—
9.7
9.6
9.8
9.7
9.7
9.8
9.7
9.85
9.95
9.85
9.75
9.95
9.85
9.9
9.85
9.9
9.95
9.85
9.9
9.85
9.9
10.05
9.9
10
9.85
10
9.95
10
9.95
10
9.95
10
9.95
10
9.85
9.95
9.8
9.95
9.95
9.95
9.9
10.05
9.9
10
9.8
10.05
10
10
10
9.95

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
CC5A/CD5AA036
CK3BA036
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CC5A/CD5AA036
CK3BA036
CK3BA042
CK5A/CK5BA036
CK5A/CK5BN042

036-C, D

CC5A/CD5AA036
CK3BA036
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CK3BA036
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CC5A/CD5AA036
CK3BA036
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CK3BA036
CK3BA042
CK5A/CK5BA042
CK5A/CK5BW036
CC5A/CD5AA042*
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
CE3AA042
CE3AA048
CF5AA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BN042
CK5A/CK5BN048
CK5A/CK5BW048
F(A,B)4(A,B)N(F,B)042
F(A,B)4(A,B)N(F,B)048
FC4(B,C)N(F,B)042
FC4(B,C)N(F,B)048
FG3AAA048
FK4(C,D)NB006
FK4(C,D)NF003
FK4(C,D)NF005

042-C, D
CC5A/CD5AA042
CC5A/CD5AC048
CD5AA048
CE3AA042
CE3AA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BE042
CK5A/CK5BT042
CK5A/CK5BT048
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
CE3AA042
CE3AA048
CK3BA042
CK3BA048

FACTORYBRYANT GAS
TOT.
SUPPLIED
FURNACE OR
CAP.
ENHANCESTANDARD
ACCESSORY
BTUH
MENT
RATING
TDR†
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
34,600
NONE
11.00
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
34,600
NONE
11.00
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
33,000
NONE
10.50
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
34,600
NONE
11.00
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
34,600
NONE
11.00
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
34,000
NONE
10.50
—
39,500
NONE
10.00
10.20
39,000
NONE
10.00
10.50
39,500
NONE
10.00
10.20
40,000
NONE
10.10
10.50
40,000
NONE
10.10
10.50
39,500
NONE
10.00
10.20
39,500
NONE
10.10
10.50
40,000
NONE
10.10
10.50
39,500
NONE
10.00
10.20
40,000
NONE
10.10
10.50
39,500
NONE
10.00
10.20
40,000
NONE
10.10
10.50
38,500
NONE
10.00
10.20
39,000
NONE
10.10
10.50
40,000
NONE
10.10
10.50
39,500
TDR
10.00
—
40,500
TDR
10.50
—
39,500
TDR & TXV
10.00
—
40,500
TDR & TXV
10.50
—
40,000
NONE
10.10
10.50
41,500
TDR & TXV
11.50
—
40,000
TDR & TXV
11.00
—
41,000
TDR & TXV
11.20
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
39,500
TDR
11
11
39,000
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
39,500
TDR
11
11
39,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11
39,500
TDR
11
11
40,000
TDR
11
11

See notes on page 14.

—11—

ACCESSORY
TXV‡
11.00
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.20
10.50
10.20
10.50
10.50
10.20
10.50
10.50
10.20
10.50
10.20
10.50
10.20
10.50
10.50
10.00
10.50
—
—
10.50
—
—
—
10.05
10.05
10.15
10.1
10.1
10.05
10.15
10.05
10.15
10.1
10.05
10.15
10.1
10.15
10.05
10.25
10.25
10.2
10.2
10.15
10.25

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
CE3AA042
CE3AA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048

042-C, D

CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
CE3AA042
CE3AA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CK3BA042
CK5A/CK5BN042
CC5A/CD5AA042
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048
CC5A/CD5AA042
CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BA048

048-C

CK3BA042
CK3BA048
CK5A/CK5BA042
CK5A/CK5BW048
CD5AA048*
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CE3AA048
CE3AA060
CF5AA048
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BN048
CK5A/CK5BN060
CK5A/CK5BW048
CK5A/CK5BX060
CK3BA048
CK3BA060
F(A,B)4(A,B)N(F,B)048
F(A,B)4(A,B)N(F,B)060

TOT.
CAP.
BTUH

FACTORYSUPPLIED
ENHANCEMENT

STANDARD
RATING

39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
40,000
TDR
11
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
39,500
TDR
11
39,000
TDR
11
39,500
TDR
11
40,000
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
40,000
TDR
11
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
39,500
TDR
11
39,000
TDR
11
39,500
TDR
11
40,000
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
39,500
TDR
11
40,000
TDR
11
40,000
TDR
11
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
39,500
NONE
10.50
38,500
NONE
10.50
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
40,000
NONE
11.00
39,500
NONE
10.50
39,500
NONE
10.50
39,500
NONE
10.50
39,500
NONE
10.50
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
39,500
NONE
10.50
39,500
NONE
10.50
39,500
NONE
10.50
39,500
NONE
10.50
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
40,000
NONE
11.00
39,500
NONE
10.50
39,500
NONE
11.00
39,500
NONE
10.50
39,500
NONE
11.00
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
39,500
NONE
10.50
39,500
NONE
11.00
39,500
NONE
10.50
39,500
NONE
11.00
46,000
NONE
10.20
46,000
NONE
10.20
45,000
NONE
10.00
46,000
NONE
10.20
47,500
NONE
10.50
46,500
NONE
10.20
48,000
NONE
10.30
46,000
NONE
10.30
46,000
NONE
10.20
46,000
NONE
10.20
44,500
NONE
10.20
46,000
NONE
10.20
46,000
NONE
10.20
47,500
NONE
10.50
46,000
NONE
10.20
46,000
NONE
10.20
46,500
TDR
10.50
48,000
TDR
10.50

See notes on page 14.

—12—

BRYANT GAS
FURNACE OR
ACCESSORY
TDR†

ACCESSORY
TXV‡

11
11
11
11
11

10.15
10.25
10.15
10.25
10.25

11
11
11
11
11
11
11
11
11
11
11
11
11
11

10.15
10.15
10.05
10.25
10.3
10.2
10.2
10.15
10.25
10.15
10.25
10.15
10.25
10.25

11
11
11
11
11
11
11
11
11
11
11
11
11
11

10.15
10.2
10.1
10.3
10.3
10.2
10.25
10.15
10.3
10.15
10.3
10.15
10.3
10.3

—
—

10.50
10.50

—
—
—
—
—

11.00
10.50
10.50
10.50
10.50

—
—
—
—

10.50
10.50
10.50
10.50

—
—
—
—
—

11.00
10.50
11.00
10.50
11.00

—
—
—
—
10.50
10.50
10.20
10.50
11.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.00
10.50
10.50
—
—

10.50
11.00
10.50
11.00
10.50
10.50
10.20
10.50
11.00
10.50
10.50
10.50
10.50
10.50
10.50
10.50
10.50
11.00
10.50
10.50
10.50
10.50

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
FB4(A,B)NB070
FC4(B,C)N(F,B)048
FC4(B,C)N(F,B)060
FC4(B,C)NB054
FC4(B,C)NB070
FG3AAA048
FG3AAA060
FK4(C,D)NB006
FK4(C,D)NF005
CC5A/CD5AC048
CD5AA048
CE3AA048
CE3AA060
CK3BA048
CK5A/CK5BA048
CK5A/CK5BT048
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CD5AA048
CE3AA048
CE3AA060
CK3BA048
CK3BA060
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060

048-C

CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CD5AA048
CE3AA048
CE3AA060
CK3BA048
CK3BA060
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CD5AA048
CE3AA048
CE3AA060
CK3BA048
CK3BA060
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK3BA048
CK3BA060
CK5A/CK5BA048
CK3BA060
CK5A/CK5BA060
CK5A/CK5BN060
CK5A/CK5BX060
CC5A/CD5AW060
CK3BA048
CK3BA060
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BX060
CK3BA048
CK3BA060
CK5A/CK5BA060
CK5A/CK5BW048
CK5A/CK5BX060

FACTORYBRYANT GAS
TOT.
SUPPLIED
FURNACE OR
CAP.
ENHANCESTANDARD
ACCESSORY
BTUH
MENT
RATING
TDR†
48,000
TDR
11.00
—
46,500
TDR & TXV
10.40
—
47,500
TDR & TXV
10.50
—
48,000
TDR & TXV
11.00
—
48,000
TDR & TXV
11.00
—
46,000
NONE
10.00
10.50
47,500
NONE
10.30
10.50
48,000
TDR & TXV
11.50
—
47,500
TDR & TXV
11.00
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
46,000
TDR
11
11
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
47,000
TDR
11
11
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
46,000
TDR
11
11
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
47,000
TDR
11
11
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
46,000
TDR
11
11
45,500
TDR
11
11
45,500
TDR
11
11
46,500
TDR
11
11
45,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
46,500
TDR
11
11
45,500
TDR
10.5
10.5
47,000
TDR
11
11
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
45,000
NONE
10.50
—
45,500
NONE
10.50
—
45,000
NONE
10.50
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
45,500
NONE
10.50
—
45,500
NONE
10.50
—
45,500
NONE
10.50
—
47,000
NONE
11.00
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
46,500
NONE
11.00
—
45,000
NONE
10.50
—
45,500
NONE
11.00
—
45,000
NONE
10.50
—
45,500
NONE
11.00
—
47,000
NONE
11.00
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
45,000
NONE
10.50
—
45,500
NONE
11.00
—
45,500
NONE
11.00
—
45,000
NONE
10.50
—
47,000
NONE
11.00
—

See notes on page 14.

—13—

ACCESSORY
TXV‡
11.00
—
—
—
—
10.50
10.50
—
—
9.5
9.55
9.55
9.85
9.6
9.6
9.6
9.75
9.65
9.7
9.7
9.75
10
9.75
9.95
9.75
9.95
9.75
9.95
9.75
10.2
9.75
9.6
9.7
10
9.7
9.7
10
9.7
9.95
9.7
9.95
9.7
9.95
9.7
10.15
9.8
9.7
9.75
10.05
9.75
9.75
10.05
9.75
10
9.75
10
9.75
10
9.75
10.2
10.50
10.50
10.50
10.50
10.50
10.50
11.00
11.00
10.50
11.00
10.50
11.00
11.00
10.50
11.00
11.00
10.50
11.00

COMBINATION RATINGS Continued
UNIT
SIZE-SERIES

INDOOR
MODEL
CC5A/CD5AW060*
CC5A/CD5AA060
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BN060
CK5A/CK5BX060
F(A,B)4(A,B)N(F,B)060
FB4(A,B)NB070
FC4(B,C)NB070
FC4(B,C)N(F,B)060
FG3AAA060
FK4(C,D)NB006

060-C

CC5A/CD5AA060
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CC5A/CD5AA060
CC5A/CD5AW060
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CC5A/CD5AA060
CC5A/CD5AW060
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060

TOT.
CAP.
BTUH

FACTORYSUPPLIED
ENHANCEMENT

STANDARD
RATING

57,000
NONE
10.20
54,500
NONE
10.00
57,500
NONE
10.20
54,500
NONE
10.00
54,500
NONE
10.00
54,500
NONE
10.00
57,000
NONE
10.20
57,500
TDR
10.00
58,500
TDR
10.50
58,500
TDR & TXV
10.50
57,500
TDR & TXV
10.00
56,500
NONE
10.20
58,000
TDR & TXV
11.00
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
55,000
TDR
10.5
56,500
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,500
TDR
10.5
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
55,000
TDR
10.5
56,000
TDR
10.5
56,500
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,500
TDR
10.5
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
55,000
TDR
10.5
56,000
TDR
10.5
56,500
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,000
TDR
10.5
56,500
TDR
10.5

BRYANT GAS
FURNACE OR
ACCESSORY
TDR†

ACCESSORY
TXV‡

10.50
10.20
10.50
10.20
10.20
10.20
10.50
—
—
—
—
10.50
—

10.50
10.20
10.50
10.20
10.20
10.20
10.50
10.00
10.50
—
—
10.50
—

10.5
10.5
10.5
10.5
10.5
10.5

9
9.3
9.15
9.15
9.15
9.4

10.5
10.5
10.5
10.5
10.5
10.5
10.5

9
9.25
9.3
9.15
9.15
9.15
9.4

10.5
10.5
10.5
10.5
10.5
10.5
10.5

9.1
9.3
9.35
9.2
9.2
9.2
9.45

* Tested combination.
† In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
‡ Based on computer simulation, TXV must be hard shutoff type.
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

—14—

DETAILED COOLING CAPACITIES*
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85
Capacity
MBtuh†

CFM

EWB

Total

95

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

105
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C018-C, D Outdoor Section With CC5A/CD5AA018 Indoor Section
525

600

675

72
67
62
57
72
67
62
57
72
67
62
57

19.7
17.9
16.1
15.0
20.1
18.3
16.5
15.7
20.5
18.6
16.8
16.2

Indoor
Section
CC5A/CD5AA
CC5A/CD5AA
CE3AA
CF5AA
CK3BA
CK5A/CK5BA
CK5A/CK5BW
F(A,B)4(A,B)NF
FC4(B,C)NF
FF1DNA
FG3AA
FK4(C,D)NF

9.50
11.8
14.0
15.0
9.89
12.5
14.9
15.7
10.3
13.1
15.8
16.2
Unit
Size
018
024
024
024
024
024
018
024
024
018
024
024
018
024
024
001
002
—
—

1.69
18.6
9.09
1.80
17.5
8.66
1.91
16.3
8.23
2.01
15.2
7.80
2.12
1.65
16.8
11.4
1.75
15.8
10.9
1.85
14.7
10.5
1.94
13.6
10.0
2.04
1.60
15.1
13.6
1.70
14.1
13.0
1.79
13.1
12.5
1.88
12.1
12.0
1.96
1.58
14.3
14.3
1.68
13.5
13.5
1.77
12.8
12.8
1.86
12.0
12.0
1.95
1.73
19.0
9.47
1.84
17.8
9.03
1.95
16.6
8.60
2.06
15.4
8.17
2.16
1.68
17.2
12.0
1.79
16.1
11.6
1.89
15.0
11.1
1.99
13.8
10.6
2.08
1.64
15.5
14.4
1.74
14.4
13.8
1.83
13.4
13.2
1.92
12.4
12.4
2.01
1.62
14.9
14.9
1.72
14.1
14.1
1.82
13.3
13.3
1.91
12.5
12.5
2.01
1.76
19.3
9.83
1.88
18.1
9.39
1.99
16.9
8.95
2.09
15.6
8.51
2.20
1.72
17.5
12.6
1.83
16.3
12.2
1.93
15.2
11.7
2.03
14.0
11.2
2.13
1.68
15.8
15.2
1.78
14.7
14.5
1.87
13.7
13.7
1.97
12.7
12.7
2.06
1.67
15.4
15.4
1.77
14.6
14.6
1.87
13.7
13.7
1.97
12.9
12.9
2.06
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Unit
Capacity
Power
Section
Size
Capacity
Power
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
1.00
1.00
1.03
1.01
CC5A/CD5AA
018
1.00
0.91
1.03
1.01
024
1.02
0.91
1.05
1.01
CC5A/CD5AW
024
1.02
0.91
1.05
1.01
CE3AA
024
1.02
0.91
1.03
1.01
CK3BA
024
1.02
0.89
1.00
1.01
CK5A/CK5BA
018
1.00
0.89
1.03
1.01
024
1.02
0.89
1.03
1.01
CK5A/CK5BW
024
1.02
0.89
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
0.99
1.00
1.05
1.02
CC5A/CD5AA
018
1.02
0.93
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
1.05
1.02
0.99
1.00
CC5A/CD5AA
018
1.02
0.93
1.05
1.02
CK5A/CK5BW
024
1.02
0.94
1.02
1.01
CK3BA
024
1.02
0.94
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
1.05
0.94
1.05
0.94
CC5A/CD5AA
018
1.02
0.93
—
—
CK3BA
024
1.02
0.94
—
—
CK5A/CK5BW
024
1.02
0.94

See notes on page 24.

—15—

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85
Capacity
MBtuh†

CFM

EWB

Total

Total
System
Sens‡ kW**

95
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

105
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C024-C, D Outdoor Section With CC5A/CD5AA024 Indoor Section
2.34
24.8
12.3
2.49
23.3
11.8
2.62
21.8
11.2
2.75
20.3
10.7
2.88
2.27
22.6
15.6
2.40
21.2
15.0
2.53
19.8
14.4
2.65
18.3
13.8
2.77
2.20
20.4
18.7
2.32
19.1
18.0
2.43
17.8
17.3
2.54
16.5
16.5
2.66
2.17
19.5
19.5
2.28
18.5
18.5
2.41
17.5
17.5
2.53
16.5
16.5
2.65
2.40
25.3
12.9
2.54
23.8
12.3
2.68
22.2
11.8
2.82
20.6
11.2
2.94
2.33
23.0
16.5
2.46
21.6
15.9
2.59
20.1
15.4
2.71
18.6
14.8
2.82
800
2.26
20.9
19.9
2.38
19.5
19.1
2.49
18.2
18.2
2.61
17.1
17.1
2.73
2.23
20.3
20.3
2.36
19.3
19.3
2.48
18.2
18.2
2.61
17.1
17.1
2.73
2.50
25.9
13.9
2.65
24.3
13.3
2.79
22.7
12.8
2.93
21.0
12.2
3.06
2.43
23.6
18.3
2.57
22.1
17.7
2.70
20.5
17.1
2.81
18.9
16.4
2.93
900
2.37
21.7
21.6
2.50
20.4
20.4
2.63
19.2
19.2
2.75
18.0
18.0
2.88
2.36
21.6
21.6
2.49
20.4
20.4
2.62
19.2
19.2
2.75
18.0
18.0
2.88
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Unit
Indoor
Unit
Section
Size
Capacity
Power
Section
Size
Capacity
Power
CC5A/CD5AA
024
1.00
1.00
CC5A/CD5AW
024
0.99
0.91
030
1.00
1.00
030
1.00
0.90
CC5A/CD5AW
024
1.00
1.00
CE3AA
024
0.99
0.91
030
1.00
1.00
030
1.00
0.90
CE3AA
024
1.01
1.00
CK3BA
024
0.99
0.90
030
1.02
1.01
030
1.00
0.90
CF5AA
024
1.00
1.00
CK5A/CK5BA
024
0.99
0.90
CK3BA
024
1.00
1.00
030
1.00
0.90
030
1.00
1.01
CK5A/CK5BW
024
0.99
0.90
CK5A/CK5BA
024
1.00
1.00
030
1.00
0.90
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
030
1.00
1.01
CK5A/CK5BW
024
1.00
1.00
CC5A/CD5AA
024
0.98
0.93
030
1.00
1.01
CK3BA
024
0.98
0.95
F(A,B)4(A,B)NF
024
1.00
1.00
030
1.01
0.95
030
1.01
1.00
CK5A/CK5BW
030
1.01
0.95
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
FC4(B,C)NF
024
1.00
1.00
030
1.02
1.00
CC5A/CD5AA
024
0.98
0.93
FF1DNA
024
1.00
1.01
CK3BA
024
0.98
0.95
030
1.02
1.02
030
1.01
0.95
FG3AAA
024
0.97
1.00
CK5A/CK5BW
024
0.98
0.95
FK4(C,D)NF
001
1.04
0.95
030
1.01
0.95
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
002
1.04
0.95
003
1.04
0.93
CC5A/CD5AA
024
0.98
0.93
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CK3BA
024
0.98
0.93
CC5A/CD5AA
024
0.99
0.91
030
1.01
0.94
030
1.00
0.90
CK5A/CK5BW
024
0.98
0.93
—
—
—
030
1.01
0.94
700

72
67
62
57
72
67
62
57
72
67
62
57

26.3
24.0
21.7
20.5
26.8
24.5
22.2
21.4
27.4
25.1
23.0
22.7

12.9
16.2
19.3
20.5
13.4
17.1
20.6
21.4
14.4
18.9
22.7
22.7

See notes on page 24.

—16—

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C030-C, D Outdoor Section With CC5A/CD5AA030 Indoor Section
875

1000

1125

72
67
62
57
72
67
62
57
72
67
62
57

32.6
29.7
26.9
25.4
33.2
30.4
27.5
26.5
33.7
30.8
28.0
27.4

15.9
20.0
23.9
25.4
16.6
21.2
25.4
26.5
17.2
22.3
26.8
27.4

2.90
2.83
2.74
2.69
2.97
2.89
2.81
2.77
3.03
2.95
2.87
2.85

30.8
28.1
25.3
24.2
31.4
28.6
25.9
25.2
31.8
29.0
26.3
26.0

15.2
19.3
23.1
24.2
15.9
20.4
24.6
25.2
16.5
21.5
25.8
26.0

3.11
3.01
2.90
2.86
3.18
3.08
2.98
2.95
3.24
3.15
3.04
3.03

29.0
26.4
23.7
23.0
29.5
26.8
24.3
23.9
29.8
27.2
24.7
24.7

14.6
18.5
22.3
23.0
15.2
19.7
23.6
23.9
15.8
20.8
24.7
24.7

3.30
3.19
3.07
3.03
3.37
3.26
3.14
3.13
3.44
3.33
3.21
3.21

27.2
24.6
22.2
21.8
27.6
25.0
22.7
22.6
27.8
25.3
23.3
23.3

13.9
17.8
21.4
21.8
14.5
19.0
22.6
22.6
15.1
20.1
23.3
23.3

3.49
3.35
3.22
3.20
3.57
3.43
3.30
3.30
3.63
3.50
3.39
3.39

25.3
22.9
20.7
20.5
25.6
23.3
21.3
21.3
25.9
23.5
21.9
21.9

13.2
17.2
20.5
20.5
13.8
18.3
21.3
21.3
14.4
19.3
21.9
21.9

Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section

CC5A/CD5AA

Unit
Size

Cooling
Capacity

Power

030
1.00
1.00
036
1.01
1.01
CC5A/CD5AW
030
1.00
1.00
CD5AW
036
1.01
1.01
CE3AA
030
0.99
1.00
036
1.01
1.01
CF5AA
036
1.01
1.01
CK3BA
030
1.00
1.00
036
1.01
1.01
CK5A/CK5BA
030
1.00
1.00
036
1.01
1.01
CK5A/CK5BN
036
0.94
1.01
CK5A/CK5BW
030
1.00
1.00
036
1.01
1.01
F(A,B)4(A,B)NF
030
0.99
1.00
036
1.01
1.02
FC4(B,C)NF
030
0.99
1.00
036
1.01
1.02
FF1DNA
030
0.99
1.01
FG3AAA
036
1.01
1.00
FK4(C,D)NF
001
1.03
0.97
002
1.03
0.97
003
1.03
0.97
005
1.05
0.94
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CC5A/CD5AA
030
1.00
0.94
036
1.04
0.95
CC5A/CD5AW
030
1.00
0.94
CE3AA
030
1.00
0.93
036
1.02
0.95
CK3BA
030
1.00
0.94
036
1.04
0.94
CK5A/CK5BA
030
1.00
0.94
036
1.04
0.94
CK5A/CK5BT
036
1.04
0.94
CK5A/CK5BW
030
1.00
0.94
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA
030
1.00
0.93
036
1.04
0.93
CC5A/CD5AW
030
1.00
0.93
036
1.04
0.93
—
—
—

Indoor
Section

CE3AA

Unit
Size

Cooling
Capacity

Power

030
1.00
0.92
036
1.02
0.93
CK3BA
030
1.00
0.93
036
1.04
0.93
CK5A/CK5BA
030
1.00
0.93
036
1.04
0.93
CK5A/CK5BW
030
1.00
0.93
036
1.04
0.93
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
0.95
CC5A/CD5AA
030
1.01
0.97
CK3BA
030
1.01
0.97
036
1.01
0.97
CK5A/CK5BW
030
1.01
0.97
036
1.01
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
0.95
CC5A/CD5AA
030
1.01
0.97
CK3BA
030
1.01
0.98
036
1.01
0.98
CK5A/CK5BA
036
1.01
0.98
CK5A/CK5BN
036
0.94
0.97
CK5A/CK5BW
030
1.01
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
0.95
CC5A/CD5AA
030
1.01
0.97
CK3BA
030
1.01
0.97
036
1.01
0.97
CK5A/CK5BW
030
1.01
0.97
036
1.01
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
0.97
CK3BA
030
1.01
0.98
036
1.01
0.97
CK5A/CK5BW
030
1.01
0.98
036
1.01
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
0.95
CC5A/CD5AA
030
1.01
0.95
CK3BA
030
1.01
0.96
036
1.01
0.95
CK5A/CK5BW
030
1.01
0.96
036
1.01
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
0.95
CK3BA
030
1.01
0.96
036
1.01
0.96
CK5A/CK5BW
036
1.01

See notes on page 24.

—17—

3.67
3.52
3.37
3.37
3.74
3.60
3.47
3.47
3.82
3.67
3.56
3.57

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C036-C, D Outdoor Section With CC5A/CD5AA036 Indoor Section
1050

1200

1350

72
67
62
57
72
67
62
57
72
67
62
57

39.6
36.0
32.7
31.3
40.3
36.7
33.4
32.6
40.8
37.2
34.0
33.7

19.6
24.9
29.8
31.3
20.5
26.4
31.8
32.6
21.4
27.9
33.5
33.7

3.42
3.32
3.23
3.19
3.49
3.40
3.31
3.29
3.56
3.47
3.38
3.38

37.4
34.0
30.7
29.8
38.1
34.6
31.4
31.1
38.5
35.0
32.1
32.1

18.8
24.0
28.9
29.8
19.7
25.5
30.7
31.1
20.6
27.0
32.1
32.1

3.65
3.54
3.43
3.39
3.73
3.62
3.51
3.50
3.80
3.69
3.59
3.59

35.2
31.9
28.8
28.3
35.8
32.4
29.5
29.5
36.1
32.8
30.4
30.4

18.0
23.2
27.8
28.3
18.9
24.7
29.4
29.5
19.7
26.1
30.4
30.4

3.88
3.75
3.62
3.59
3.96
3.83
3.71
3.71
4.03
3.91
3.80
3.80

32.9
29.8
27.0
26.8
33.3
30.3
27.8
27.8
33.6
30.6
28.6
28.6

17.2
22.3
26.7
26.8
18.1
23.9
27.8
27.8
18.9
25.3
28.6
28.6

4.08
3.94
3.79
3.79
4.17
4.03
3.90
3.90
4.25
4.11
4.00
4.00

30.5
27.7
25.3
25.3
31.0
28.1
26.2
26.2
31.4
28.3
26.9
26.9

16.4
21.5
25.3
25.3
17.3
23.0
26.2
26.2
18.1
24.3
26.9
26.9

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Unit
Indoor
Unit
Size
Capacity
Power
Section
Size
Capacity
Power
036
1.00
1.00
CK5A/CK5BE
042
0.99
0.91
042
1.00
1.00
CK5A/CK5BT
036
0.99
0.92
CC5A/CD5AW
042
1.00
1.00
042
0.99
0.92
CD5AW
036
1.00
1.00
CK5A/CK5BW
036
0.99
0.92
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CE3AA
036
0.99
1.00
042
1.00
1.00
CC5A/CD5AA
036
0.99
0.92
CF5AA
036
1.00
1.00
042
0.99
0.91
CK3BA
036
1.00
1.00
CC5A/CD5AW
036
0.99
0.92
042
1.00
1.00
042
0.99
0.91
CK5A/CK5BA
036
1.00
1.00
CE3AA
036
0.98
0.91
042
1.00
1.00
042
0.99
0.91
CK5A/CK5BN
036
0.92
0.97
CK3BA
036
0.99
0.92
042
0.97
1.00
042
0.99
0.91
CK5A/CK5BW
036
1.00
1.00
CK5A/CK5BA
036
0.99
0.92
F(A,B)4(A,B)NF
036
0.98
1.01
042
0.99
0.91
F(A,B)4(A,B)N(F,B)
042
1.01
1.01
CK5A/CK5BT
036
0.99
0.92
FC4(B,C)NF
036
0.98
1.01
042
0.99
0.91
FC4(B,C)N(F,B)
042
1.01
1.01
CK5A/CK5BW
036
0.99
0.92
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
FG3AAA
036
0.98
0.99
FK4(C,D)NB
005
1.02
0.95
CC5A/CD5AA
042
0.99
0.91
006
1.02
0.95
CC5A/CD5AW
036
0.99
0.92
FK4(C,D)NF
001
1.00
0.98
042
0.99
0.91
002
1.00
0.98
CE3AA
036
0.98
0.92
003
1.01
0.94
042
0.99
0.91
005
1.02
0.93
CK3BA
042
0.99
0.91
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CK5A/CK5BA
042
0.99
0.91
CC5A/CD5AA
036
0.99
0.94
CK5A/CK5BW
036
0.99
0.92
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CE3AA
036
0.98
0.93
042
0.99
0.93
CC5A/CD5AA
042
0.99
0.90
CK3BA
036
0.99
0.94
CC5A/CD5AW
036
0.99
0.92
CK5A/CK5BA
036
0.99
0.94
042
0.99
0.91
CK5A/CK5BE
042
0.99
0.93
CE3AA
036
0.98
0.91
CK5A/CK5BT
036
0.99
0.94
042
0.99
0.91
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CK3BA
042
0.99
0.91
CC5A/CD5AA
036
0.99
0.92
CK5A/CK5BA
042
0.99
0.91
042
0.99
0.91
CK5A/CK5BT
042
0.99
0.91
CC5A/CD5AW
036
0.99
0.92
CK5A/CK5BW
036
0.99
0.92
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CE3AA
036
0.98
0.92
042
0.99
0.92
CC5A/CD5AA
036
1.00
0.92
CK3BA
036
0.99
0.92
CK3BA
036
0.98
0.94
042
0.99
0.92
042
0.98
0.93
CK5A/CK5BA
036
0.99
0.92
CK5A/CK5BA
042
0.98
0.93
042
0.99
0.92
CK5A/CK5BW
036
0.98
0.94
Indoor
Section
CC5A/CD5AA

See notes on page 24.

—18—

4.28
4.12
3.98
3.98
4.38
4.21
4.10
4.10
4.47
4.29
4.20
4.21

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C036-C, D Outdoor Section With CC5A/CD5AA036 Indoor Section Continued
1050

1200

1350

72
67
62
57
72
67
62
57
72
67
62
57

39.6
36.0
32.7
31.3
40.3
36.7
33.4
32.6
40.8
37.2
34.0
33.7

19.6
24.9
29.8
31.3
20.5
26.4
31.8
32.6
21.4
27.9
33.5
33.7

3.42
3.32
3.23
3.19
3.49
3.40
3.31
3.29
3.56
3.47
3.38
3.38

37.4
34.0
30.7
29.8
38.1
34.6
31.4
31.1
38.5
35.0
32.1
32.1

18.8
24.0
28.9
29.8
19.7
25.5
30.7
31.1
20.6
27.0
32.1
32.1

3.65
3.54
3.43
3.39
3.73
3.62
3.51
3.50
3.80
3.69
3.59
3.59

35.2
31.9
28.8
28.3
35.8
32.4
29.5
29.5
36.1
32.8
30.4
30.4

18.0
23.2
27.8
28.3
18.9
24.7
29.4
29.5
19.7
26.1
30.4
30.4

3.88
3.75
3.62
3.59
3.96
3.83
3.71
3.71
4.03
3.91
3.80
3.80

32.9
29.8
27.0
26.8
33.3
30.3
27.8
27.8
33.6
30.6
28.6
28.6

17.2
22.3
26.7
26.8
18.1
23.9
27.8
27.8
18.9
25.3
28.6
28.6

4.08
3.94
3.79
3.79
4.17
4.03
3.90
3.90
4.25
4.11
4.00
4.00

30.5
27.7
25.3
25.3
31.0
28.1
26.2
26.2
31.4
28.3
26.9
26.9

16.4
21.5
25.3
25.3
17.3
23.0
26.2
26.2
18.1
24.3
26.9
26.9

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Unit
Indoor
Unit
Section
Size
Capacity
Power
Section
Size
Capacity
Power
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CK5A/CK5BA
042
0.98
0.94
CC5A/CD5AA
036
1.00
0.92
CK5A/CK5BW
036
0.98
0.94
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA
036
0.98
0.94
042
0.98
0.94
CC5A/CD5AA
036
1.00
0.92
CK5A/CK5BA
036
0.98
0.94
CK3BA
036
0.98
0.92
CK5A/CK5BN
042
0.95
0.94
042
0.98
0.92
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CK5A/CK5BA
042
0.98
0.92
CC5A/CD5AA
036
1.00
0.92
CK5A/CK5BW
036
0.98
0.92
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA
036
0.98
0.93
042
0.98
0.93
CK3BA
036
0.98
0.93
CK5A/CK5BA
042
0.98
0.93
042
0.98
0.92
CK5A/CK5BW
036
0.98
0.93
CK5A/CK5BA
042
0.98
0.92
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK5A/CK5BW
036
0.98
0.93
CK3BA
036
0.98
0.94
—
—
—
042
0.98
0.94
See notes on page 24.

—19—

4.28
4.12
3.98
3.98
4.38
4.21
4.10
4.10
4.47
4.29
4.20
4.21

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C042-C, D Outdoor Section With CC5A/CD5AA042 Indoor Section
1225

1400

1575

72
67
62
57
72
67
62
57
72
67
62
57

45.2
41.2
37.4
35.9
46.0
42.0
38.2
37.3
46.5
42.5
38.9
38.5

22.4
28.3
34.0
35.9
23.4
30.1
36.2
37.3
24.3
31.7
38.1
38.5

4.01
3.89
3.77
3.72
4.10
3.98
3.86
3.83
4.19
4.06
3.95
3.94

42.6
38.8
35.3
34.2
43.3
39.5
36.1
35.5
43.8
40.0
36.7
36.6

21.4
27.4
32.9
34.2
22.4
29.1
35.0
35.5
23.3
30.7
36.6
36.6

4.25
4.11
3.97
3.93
4.34
4.20
4.08
4.05
4.43
4.29
4.17
4.16

40.1
36.6
33.2
32.5
40.6
37.1
34.0
33.7
41.2
37.5
34.8
34.7

20.5
26.4
31.8
32.5
21.4
28.1
33.7
33.7
22.4
29.7
34.8
34.7

4.48
4.33
4.18
4.15
4.57
4.43
4.30
4.28
4.67
4.52
4.40
4.40

37.6
34.3
31.1
30.8
38.1
34.8
31.9
31.9
38.4
35.1
32.8
32.8

19.6
25.5
30.6
30.8
20.6
27.2
31.9
31.9
21.4
28.8
32.8
32.8

4.72
4.55
4.39
4.38
4.82
4.65
4.51
4.51
4.90
4.74
4.63
4.63

35.1
32.0
29.1
29.1
35.5
32.4
30.1
30.1
35.8
32.6
30.9
30.9

18.7
24.6
29.1
29.1
19.7
26.3
30.1
30.1
20.6
27.8
30.9
30.9

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Unit
Size
Capacity
Power
042
1.00
1.00
048
0.99
1.00
042
1.00
1.00
048
1.01
1.00
CE3AA
042
1.00
1.00
048
1.00
1.00
CF5AA
048
1.01
1.00
CK3BA
042
1.00
1.00
048
1.01
1.00
CK5A/CK5BA
042
1.00
1.00
048
1.01
1.00
CK5A/CK5BN
042
0.97
1.00
048
0.99
1.00
CK5A/CK5BW
048
1.01
1.00
F(A,B)4(A,B)N(F,B)
042
1.00
1.01
048
1.03
1.02
FC4(B,C)N(F,B)
042
1.00
1.01
048
1.03
1.02
FG3AAA
048
0.10
1.00
FK4(C,D)NF
003
1.01
0.92
005
1.04
0.95
FK4(C,D)NB
006
1.05
0.94
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
0.99
0.94
CC5A/CD5AC
048
0.98
0.92
CD5AA
048
1.00
0.94
CE3AA
042
0.99
0.93
048
1.00
0.94
CK3BA
042
0.99
0.93
048
1.00
0.94
CK5A/CK5BA
042
0.99
0.93
048
1.00
0.94
CK5A/CK5BE
042
0.99
0.93
CK5A/CK5BT
042
0.99
0.93
048
1.00
0.94
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
0.99
0.93
CC5A/CD5AC
048
0.98
0.91
CC5A/CD5AW
042
0.99
0.93
048
1.00
0.93
Indoor
Section
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW

See notes on page 24.

—20—

Cooling
Unit
Size
Capacity
Power
048
1.00
0.93
042
0.99
0.92
048
1.00
0.93
CK3BA
042
0.99
0.93
048
1.00
0.93
CK5A/CK5BA
042
0.99
0.92
048
1.00
0.93
CK5A/CK5BT
042
0.99
0.93
048
1.00
0.93
CK5A/CK5BW
048
1.00
0.93
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
0.99
0.93
CC5A/CD5AC
048
0.98
0.91
CC5A/CD5AW
042
0.99
0.93
048
1.00
0.93
CD5AA
048
1.00
0.92
CE3AA
042
0.99
0.92
048
1.00
0.93
CK3BA
042
0.99
0.93
048
1.00
0.93
CK5A/CK5BA
042
0.99
0.92
048
1.00
0.93
CK5A/CK5BT
042
0.99
0.93
048
1.00
0.93
CK5A/CK5BW
048
1.00
0.93
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
0.99
0.92
CC5A/CD5AC
048
0.98
0.91
CC5A/CD5AW
042
0.99
0.93
048
1.00
0.92
CD5AA
048
1.00
0.92
CE3AA
042
0.99
0.92
048
1.00
0.93
CK3BA
042
0.99
0.92
048
1.00
0.92
CK5A/CK5BA
042
0.99
0.92
048
1.00
0.92
CK5A/CK5BT
042
0.99
0.92
048
1.00
0.92
CK5A/CK5BW
048
1.00
0.92
Indoor
Section
CD5AA
CE3AA

4.95
4.77
4.60
4.59
5.05
4.87
4.74
4.73
5.14
4.96
4.86
4.85

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C042-C, D Outdoor Section With CC5A/CD5AA042 Indoor Section continued
1225

1400

1575

72
67
62
57
72
67
62
57
72
67
62
57

45.2
41.2
37.4
35.9
46.0
42.0
38.2
37.3
46.5
42.5
38.9
38.5

22.4
28.3
34.0
35.9
23.4
30.1
36.2
37.3
24.3
31.7
38.1
38.5

4.01
3.89
3.77
3.72
4.10
3.98
3.86
3.83
4.19
4.06
3.95
3.94

42.6
38.8
35.3
34.2
43.3
39.5
36.1
35.5
43.8
40.0
36.7
36.6

21.4
27.4
32.9
34.2
22.4
29.1
35.0
35.5
23.3
30.7
36.6
36.6

4.25
4.11
3.97
3.93
4.34
4.20
4.08
4.05
4.43
4.29
4.17
4.16

40.1
36.6
33.2
32.5
40.6
37.1
34.0
33.7
41.2
37.5
34.8
34.7

20.5
26.4
31.8
32.5
21.4
28.1
33.7
33.7
22.4
29.7
34.8
34.7

4.48
4.33
4.18
4.15
4.57
4.43
4.30
4.28
4.67
4.52
4.40
4.40

37.6
34.3
31.1
30.8
38.1
34.8
31.9
31.9
38.4
35.1
32.8
32.8

19.6
25.5
30.6
30.8
20.6
27.2
31.9
31.9
21.4
28.8
32.8
32.8

4.72
4.55
4.39
4.38
4.82
4.65
4.51
4.51
4.90
4.74
4.63
4.63

35.1
32.0
29.1
29.1
35.5
32.4
30.1
30.1
35.8
32.6
30.9
30.9

18.7
24.6
29.1
29.1
19.7
26.3
30.1
30.1
20.6
27.8
30.9
30.9

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Unit
Section
Size
Capacity
Power
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CK3BA
042
1.00
0.96
CK5A/CK5BN
042
0.97
0.96
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
1.01
0.93
CK3BA
042
1.00
0.95
048
1.00
0.95
CK5A/CK5BA
042
1.00
0.95
048
1.00
0.95
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK3BA
042
1.00
0.96
048
1.00
0.96
—
—
—

Cooling
Unit
Size
Capacity
Power
042
1.00
0.96
048
1.00
0.96
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
1.01
0.93
CK3BA
042
1.00
0.94
048
1.00
0.94
CK5A/CK5BA
042
1.00
0.94
048
1.00
0.94
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA
042
1.00
0.94
CK3BA
042
1.00
0.94
048
1.00
0.94
CK5A/CK5BW
048
1.00
0.94
Indoor
Section
CK5A/CK5BA

See notes on page 24.

—21—

4.95
4.77
4.60
4.59
5.05
4.87
4.74
4.73
5.14
4.96
4.86
4.85

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†

Total
System
Sens‡ kW**

Total

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C048-C Outdoor Section With CC5A/CD5AA048 Indoor Section
1450

1600

1750

72
67
62
57
72
67
62
57
72
67
62
57

54.9
50.1
45.6
43.5
55.6
50.8
46.3
44.7
56.2
51.4
46.8
45.8

27.0
34.1
41.0
43.5
27.9
35.6
42.9
44.7
28.7
37.0
44.7
45.8

4.53
4.42
4.33
4.29
4.61
4.50
4.40
4.37
4.69
4.57
4.47
4.45

52.6
47.9
43.6
41.9
53.2
48.6
44.2
43.1
53.8
49.1
44.7
44.1

26.2
33.2
40.0
41.9
27.0
34.7
41.9
43.1
27.8
36.1
43.5
44.1

4.93
4.81
4.72
4.68
5.01
4.89
4.79
4.76
5.08
4.96
4.86
4.85

50.1
45.7
41.5
40.3
50.7
46.2
42.1
41.4
51.2
46.7
42.6
42.3

25.3
32.3
39.0
40.3
26.1
33.7
40.7
41.4
26.9
35.1
42.2
42.3

5.37
5.25
5.14
5.11
5.44
5.32
5.22
5.20
5.52
5.40
5.29
5.28

47.5
43.3
39.3
38.6
48.1
43.8
39.9
39.6
48.5
44.2
40.5
40.4

24.3
31.3
37.8
38.6
25.2
32.8
39.4
39.6
25.9
34.2
40.5
40.4

5.85
5.72
5.60
5.58
5.92
5.80
5.68
5.67
6.00
5.87
5.76
5.76

44.8
40.8
37.1
36.8
45.3
41.2
37.7
37.7
45.7
41.6
38.5
38.5

23.4
30.3
36.5
36.8
24.2
31.8
37.7
37.7
24.9
33.1
38.5
38.5

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Unit
Size
Capacity
Power
060
1.00
1.00
048
0.98
0.99
048
1.00
1.00
060
1.03
1.01
CD5AA
048
1.00
1.00
CE3AA
048
1.01
1.00
060
1.04
1.02
CF5AA
048
1.00
0.99
CK3BA
048
1.00
1.00
060
1.00
1.01
CK5A/CK5BA
048
1.00
1.00
060
1.00
1.01
CK5A/CK5BN
048
0.97
0.98
060
1.00
1.01
CK5A/CK5BW
048
1.00
1.00
CK5A/CK5BX
060
1.03
1.01
F(A,B)4A(A,B)N(F,B)
048
1.01
1.02
060
1.04
1.05
FB4(A,B)NB
070
1.04
1.02
FC4(B,C)N(F,B)
048
1.01
1.02
060
1.03
1.04
FC4(B,C)NB
054
1.04
1.02
070
1.04
1.02
FG3AAA
048
1.00
1.00
060
1.03
1.01
FK4(C,D)NB
006
1.04
0.95
FK4(C,D)NF
005
1.03
0.96
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AC
048
0.98
0.95
CD5AA
048
0.98
0.95
CE3AA
048
0.98
0.95
060
1.00
0.94
CK3BA
048
0.98
0.95
CK5A/CK5BA
048
0.98
0.95
CK5A/CK5BT
048
0.98
0.95
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
0.99
0.94
CC5A/CD5AC
048
0.98
0.94
CC5A/CD5AW
048
0.98
0.93
CD5AA
048
0.98
0.93
CE3AA
048
0.98
0.93
060
1.00
0.92
Indoor
Section
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW

Cooling
Unit
Size
Capacity
Power
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BA
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BT
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BW
048
0.98
0.93
CK5A/CK5BX
060
1.01
0.92
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
0.99
0.94
CC5A/CD5AC
048
0.98
0.94
CC5A/CD5AW
048
0.98
0.93
060
1.00
0.93
CD5AA
048
0.98
0.93
CE3AA
048
0.98
0.93
060
1.00
0.93
CK3BA
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BA
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BT
048
0.98
0.93
060
1.00
0.93
CK5A/CK5BW
048
0.98
0.93
CK5A/CK5BX
060
1.01
0.92
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA
060
0.99
0.93
CC5A/CD5AC
048
0.98
0.93
CC5A/CD5AW
048
0.98
0.93
060
1.00
0.92
CD5AA
048
0.98
0.93
CE3AA
048
0.98
0.93
060
1.00
0.92
CK3BA
048
0.98
0.93
060
1.00
0.92
CK5A/CK5BA
048
0.98
0.93
060
1.00
0.92
CK5A/CK5BT
048
0.98
0.93
060
1.00
0.92
CK5A/CK5BW
048
0.98
0.93
CK5A/CK5BX
060
1.01
0.92
—
—
—
Indoor
Section
CK3BA

See notes on page 24.

—22—

6.36
6.22
6.09
6.07
6.44
6.29
6.17
6.17
6.51
6.37
6.26
6.26

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85

95

Capacity
MBtuh†
CFM

EWB

Total

Total
System
Sens‡ kW**

105

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C048-C Outdoor Section With CC5A/CD5AA048 Indoor Section continued
1450

1600

1750

72
67
62
57
72
67
62
57
72
67
62
57

54.9
50.1
45.6
43.5
55.6
50.8
46.3
44.7
56.2
51.4
46.8
45.8

27.0
34.1
41.0
43.5
27.9
35.6
42.9
44.7
28.7
37.0
44.7
45.8

4.53
4.42
4.33
4.29
4.61
4.50
4.40
4.37
4.69
4.57
4.47
4.45

52.6
47.9
43.6
41.9
53.2
48.6
44.2
43.1
53.8
49.1
44.7
44.1

26.2
33.2
40.0
41.9
27.0
34.7
41.9
43.1
27.8
36.1
43.5
44.1

4.93
4.81
4.72
4.68
5.01
4.89
4.79
4.76
5.08
4.96
4.86
4.85

50.1
45.7
41.5
40.3
50.7
46.2
42.1
41.4
51.2
46.7
42.6
42.3

25.3
32.3
39.0
40.3
26.1
33.7
40.7
41.4
26.9
35.1
42.2
42.3

5.37
5.25
5.14
5.11
5.44
5.32
5.22
5.20
5.52
5.40
5.29
5.28

47.5
43.3
39.3
38.6
48.1
43.8
39.9
39.6
48.5
44.2
40.5
40.4

24.3
31.3
37.8
38.6
25.2
32.8
39.4
39.6
25.9
34.2
40.5
40.4

5.85
5.72
5.60
5.58
5.92
5.80
5.68
5.67
6.00
5.87
5.76
5.76

44.8
40.8
37.1
36.8
45.3
41.2
37.7
37.7
45.7
41.6
38.5
38.5

23.4
30.3
36.5
36.8
24.2
31.8
37.7
37.7
24.9
33.1
38.5
38.5

Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Indoor
Unit
Section
Size
Capacity
Power
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CK3BA
048
0.98
0.97
060
0.99
0.98
CK5A/CK5BA
048
0.98
0.97
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK3BA
060
0.99
0.98
CK5A/CK5BA
060
0.99
0.98
CK5A/CK5BN
060
0.99
0.98
CK5A/CK5BX
060
1.02
0.98
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AW
060
1.01
0.95
—
—
—

Cooling
Unit
Size
Capacity
Power
048
0.98
0.98
060
0.99
0.96
CK3BA
048
0.98
0.98
060
0.99
0.96
CK5A/CK5BN
060
0.99
0.96
CK5A/CK5BX
060
1.02
0.97
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CK3BA
048
0.98
0.96
060
0.99
0.96
CK5A/CK5BA
060
0.99
0.96
CK5A/CK5BW
048
0.98
0.96
CK5A/CK5BX
060
1.02
0.96
Indoor
Section
CJ5A/CK5AA

See notes on page 24.

—23—

6.36
6.22
6.09
6.07
6.44
6.29
6.17
6.17
6.51
6.37
6.26
6.26

DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F

EVAPORATOR
AIR

85
Capacity
MBtuh†

CFM

EWB

Total

Total
System
Sens‡ kW**

95
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

105
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

115
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

125
Capacity
MBtuh†
Total

Total
System
Sens‡ kW**

593C060-C Outdoor Section With CC5A/CD5AW060 Indoor Section
5.85
63.9
31.9
6.39
60.7
30.7
6.97
57.3
29.5
7.61
53.8
28.2
8.29
5.70
58.3
40.6
6.23
55.4
39.4
6.80
52.3
38.1
7.43
48.9
36.8
8.09
5.56
53.1
49.0
6.08
50.4
47.6
6.65
47.5
46.0
7.25
44.0
43.8
7.86
5.50
51.3
51.3
6.03
49.1
49.1
6.61
46.7
46.7
7.22
43.8
43.8
7.86
5.98
64.9
33.3
6.52
61.6
32.1
7.11
58.1
30.9
7.74
54.4
29.6
8.43
5.82
59.3
43.0
6.35
56.2
41.8
6.93
53.0
40.5
7.56
49.5
39.2
8.22
2000
5.69
54.1
52.0
6.21
51.3
50.4
6.78
48.5
48.4
7.39
45.5
45.5
8.04
5.65
53.1
53.1
6.18
50.8
50.8
6.76
48.4
48.4
7.39
45.4
45.4
8.04
6.10
65.7
34.7
6.64
62.3
33.4
7.23
58.7
32.2
7.87
55.0
30.9
8.55
5.95
60.1
45.4
6.48
56.9
44.1
7.05
53.6
42.8
7.68
50.0
41.5
8.35
2250
5.81
55.0
54.5
6.33
52.3
52.3
6.90
49.7
49.7
7.54
46.8
46.8
8.21
5.79
54.7
54.7
6.32
52.3
52.3
6.91
49.7
49.7
7.54
46.8
46.8
8.21
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Unit
Indoor
Unit
Section
Size
Capacity
Power
Section
Size
Capacity
Power
CC5A/CD5AA
060
0.96
0.98
CK5A/CK5BT
0.97
0.95
060
CC5A/CD5AW
060
1.00
1.00
CK5A/CK5BX
0.98
0.93
060
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CE3AA
060
1.01
1.00
CK3BA
060
0.96
0.98
CC5A/CD5AA
0.96
0.95
060
CK5A/CK5BA
060
0.96
0.98
CC5A/CD5AW
0.97
0.94
060
CK5A/CK5BN
060
0.96
0.99
CE3AA
0.98
0.95
060
CK5A/CK5BX
060
1.00
1.00
CK3BA
0.97
0.95
060
F(A,B)4(A,B)N(F,B)
060
1.01
1.04
CK5A/CK5BA
0.97
0.95
060
FB4(A,B)NB
070
1.03
1.02
CK5A/CK5BT
0.97
0.95
060
FC4(B,C)N(F,B)
060
1.01
1.04
CK5A/CK5BX
0.98
0.93
060
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
FC4(B,C)NB
070
1.03
1.02
FG3AAA
060
0.99
0.99
CC5A/CD5AA
0.96
0.94
060
FK4(C,D)NB
006
1.02
0.98
CC5A/CD5AW
0.97
0.94
060
COILS + 315(A,J)AV066110 VARIABLE-SPEED FURNACE
CE3AA
0.98
0.94
060
CC5A/CD5AA
0.96
0.95
CK3BA
0.97
0.95
060
060
CE3AA
0.98
0.94
CK5A/CK5BA
0.97
0.95
060
060
CK3BA
0.97
0.95
CK5A/CK5BT
0.97
0.95
060
060
CK5A/CK5BA
0.97
0.95
CK5A/CK5BX
0.98
0.93
060
060
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor
unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F entering air at the indoor coil. For sensible capacities at other than 80°F, deduct 835 Btuh per 1000 CFM of
indoor coil air for each degree below 80°F, or add 835 Btuh per 1000 CFM of indoor coil air per degree above 80°F. When the required data falls between
the published data, interpolation may be performed.
** Unit kW is total of indoor and outdoor unit kilowatts.
1750

72
67
62
57
72
67
62
57
72
67
62
57

66.9
61.1
55.7
53.2
68.1
62.3
56.8
55.2
69.0
63.1
57.7
56.9

33.0
41.8
50.3
53.2
34.5
44.2
53.4
55.2
35.8
46.6
56.2
56.9

—24—

CONDENSER ONLY RATINGS*
SST
°F

30
35
40
45
50
55

30
35
40
45
50
55

30
35
40
45
50
55

30
35
40
45
50
55

55

65

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

17.9
75.7
1.10
19.8
77.7
1.13
21.8
79.9
1.15
24.0
82.3
1.18
26.3
84.9
1.20
28.6
87.6
1.23

16.6
84.2
1.18
18.5
86.2
1.22
20.5
88.3
1.25
22.6
90.4
1.28
24.8
92.8
1.31
27.1
95.3
1.35

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

24.0
81.3
1.52
26.6
83.6
1.57
29.4
86.2
1.61
32.3
88.9
1.66
35.3
92.0
1.71
38.4
95.3
1.76

22.3
89.8
1.63
24.8
91.9
1.68
27.5
94.3
1.74
30.3
96.8
1.79
33.2
99.5
1.85
36.3
102.0
1.91

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

30.2
81.3
1.88
33.5
83.4
1.93
37.1
85.7
1.99
40.8
88.1
2.04
44.8
90.7
2.09
49.0
93.5
2.14

27.9
90.5
2.02
31.0
92.5
2.09
34.4
94.7
2.16
38.0
97.0
2.23
41.7
99.5
2.29
45.7
102.0
2.36

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

35.9
80.5
2.20
39.7
82.6
2.25
43.8
84.8
2.30
48.1
87.2
2.35
52.6
89.7
2.40
57.4
92.4
2.45

33.4
89.7
2.38
37.1
91.6
2.45
41.0
93.7
2.52
45.1
96.0
2.59
49.5
98.4
2.66
54.0
101.0
2.72

CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
593C018-C, D
15.3
14.0
12.7
93.0
102.0
111.0
1.26
1.33
1.39
17.1
15.7
14.3
94.8
104.0
112.0
1.30
1.38
1.45
19.0
17.6
16.1
96.8
105.0
114.0
1.34
1.43
1.51
21.0
19.5
17.9
98.9
107.0
116.0
1.38
1.48
1.57
23.2
21.6
19.9
101.0
110.0
118.0
1.42
1.53
1.63
25.4
23.7
22.0
103.0
112.0
120.0
1.46
1.58
1.69
593C024-C, D
20.5
18.7
16.9
98.6
108.0
117.0
1.73
1.81
1.88
22.9
21.0
19.2
101.0
109.0
118.0
1.79
1.89
1.97
25.5
23.5
21.5
103.0
111.0
120.0
1.86
1.97
2.06
28.2
26.1
24.0
105.0
114.0
122.0
1.92
2.05
2.15
31.1
28.8
26.6
108.0
116.0
124.0
1.99
2.12
2.25
34.1
31.7
29.4
110.0
118.0
127.0
2.06
2.20
2.34
593C030-C, D
25.6
23.4
21.3
99.8
109.0
118.0
2.15
2.27
2.36
28.6
26.3
24.0
102.0
111.0
120.0
2.24
2.37
2.48
31.8
29.3
26.8
104.0
113.0
122.0
2.32
2.47
2.59
35.2
32.5
29.8
106.0
115.0
124.0
2.41
2.57
2.71
38.8
35.9
33.0
108.0
117.0
126.0
2.49
2.67
2.83
42.6
39.5
36.4
111.0
120.0
129.0
2.57
2.77
2.94
593C036-C, D
30.9
28.4
25.9
98.9
108.0
118.0
2.55
2.70
2.82
34.4
31.7
29.1
101.0
110.0
119.0
2.64
2.80
2.95
38.1
35.3
32.5
103.0
112.0
121.0
2.72
2.91
3.08
42.1
39.1
36.1
105.0
114.0
123.0
2.81
3.02
3.20
46.3
43.1
39.9
107.0
116.0
125.0
2.90
3.12
3.33
50.7
47.3
43.9
110.0
119.0
127.0
2.98
3.23
3.46

See notes on page 26.

—25—

105

115

11.3
120.0
1.44
12.9
121.0
1.51
14.6
123.0
1.58
16.4
125.0
1.65
18.2
127.0
1.72
20.2
129.0
1.79

10.0
129.0
1.46
11.5
130.0
1.55
13.1
132.0
1.64
14.8
134.0
1.72
16.6
135.0
1.80
18.5
137.0
1.88

15.1
126.0
1.93
17.3
127.0
2.04
19.5
129.0
2.14
21.9
131.0
2.25
24.4
133.0
2.35
27.0
135.0
2.46

13.3
136.0
1.96
15.4
137.0
2.08
17.6
138.0
2.20
19.8
140.0
2.32
22.2
141.0
2.44
24.7
144.0
2.56

19.3
128.0
2.44
21.8
129.0
2.57
24.5
131.0
2.70
27.3
133.0
2.84
30.3
135.0
2.97
33.5
137.0
3.10

17.3
137.0
2.50
19.7
139.0
2.65
22.2
140.0
2.79
24.8
142.0
2.94
27.6
144.0
3.09
30.6
146.0
3.25

23.4
127.0
2.93
26.5
128.0
3.07
29.7
130.0
3.22
33.1
132.0
3.37
36.7
134.0
3.52
40.5
136.0
3.66

21.0
136.0
3.00
23.9
138.0
3.17
27.0
139.0
3.34
30.2
141.0
3.51
33.6
143.0
3.68
37.2
145.0
3.85

CONDENSER ONLY RATINGS* Continued
SST
°F

30
35
40
45
50
55

30
35
40
45
50
55

30
35
40
45
50
55
* ARI
KW
SDT
SST
TCG

55

65

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

40.6
81.5
2.56
44.8
83.7
2.63
49.3
86.1
2.69
54.0
88.7
2.76
58.9
91.4
2.82
64.1
94.3
2.89

37.9
90.4
2.76
42.0
92.5
2.85
46.3
94.8
2.93
50.9
97.2
3.02
55.7
99.8
3.10
60.7
103.0
3.19

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

44.5
80.0
2.76
48.7
81.8
2.81
53.1
83.7
2.86
57.8
85.8
2.92
62.7
88.0
2.99
67.9
90.4
3.06

42.6
89.8
3.03
46.7
91.5
3.09
50.9
93.3
3.14
55.5
95.3
3.20
60.2
97.4
3.27
65.3
99.8
3.35

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

55.9
84.5
3.47
61.1
86.7
3.54
66.6
89.0
3.63
72.3
91.4
3.72
78.3
94.1
3.82
84.7
96.8
3.93

53.4
94.2
3.82
58.4
96.4
3.90
63.7
98.7
3.99
69.3
101.0
4.09
75.1
104.0
4.20
81.2
106.0
4.31

CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
593C042-C, D
35.2
32.5
29.7
99.4
108.0
118.0
2.94
3.10
3.23
39.2
36.3
33.4
101.0
110.0
119.0
3.05
3.23
3.38
43.3
40.3
37.2
104.0
112.0
121.0
3.16
3.36
3.54
47.7
44.5
41.2
106.0
115.0
123.0
3.26
3.49
3.69
52.3
48.9
45.5
108.0
117.0
126.0
3.37
3.62
3.85
57.1
53.6
49.9
111.0
120.0
128.0
3.48
3.75
4.00
593C048-C
40.6
38.5
36.4
99.6
109.0
119.0
3.34
3.68
4.05
44.5
42.3
40.1
101.0
111.0
121.0
3.39
3.74
4.12
48.7
46.4
43.9
103.0
113.0
123.0
3.45
3.80
4.19
53.1
50.6
48.0
105.0
115.0
124.0
3.52
3.87
4.26
57.7
55.0
52.3
107.0
117.0
126.0
3.59
3.95
4.34
62.5
59.7
56.8
109.0
119.0
128.0
3.67
4.03
4.42
593C060-C
50.9
48.2
45.4
104.0
114.0
124.0
4.22
4.65
5.13
55.7
52.8
49.8
106.0
116.0
126.0
4.31
4.75
5.23
60.8
57.7
54.5
108.0
118.0
128.0
4.40
4.85
5.35
66.1
62.8
59.5
111.0
120.0
130.0
4.50
4.96
5.47
71.8
68.3
64.7
113.0
123.0
132.0
4.62
5.08
5.59
77.6
73.9
70.1
116.0
125.0
135.0
4.74
5.21
5.73

listing applies only to systems shown in Ratings and Performance table.
— Total Power (kW)
— Saturated Temperature Leaving Compressor (°F)
— Saturated Temperature Entering Compressor (°F)
— Gross Cooling Capacity (1000 Btuh)

—26—

105

115

26.9
127.0
3.33
30.4
128.0
3.51
34.1
130.0
3.69
38.0
132.0
3.87
42.0
134.0
4.04
46.3
137.0
4.22

24.1
136.0
3.43
27.5
137.0
3.64
31.0
139.0
3.84
34.7
141.0
4.04
38.6
143.0
4.24
42.7
145.0
4.44

34.2
129.0
4.45
37.7
131.0
4.53
41.4
132.0
4.60
45.3
134.0
4.68
49.4
136.0
4.77
53.7
138.0
4.86

31.9
139.0
4.87
35.2
140.0
4.96
38.8
142.0
5.05
42.5
144.0
5.14
46.5
146.0
5.24
50.6
147.0
5.33

42.5
134.0
5.64
46.7
136.0
5.75
51.2
138.0
5.88
56.0
140.0
6.01
60.9
142.0
6.15
66.1
144.0
6.29

39.5
143.0
6.16
43.5
145.0
6.31
47.8
147.0
6.45
52.4
150.0
6.60
57.1
152.0
6.75
62.0
154.0
6.91

SYSTEM DESIGN
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.

Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
Minimum outdoor operating air temperature without low ambient operation accessory is 55°F (12.8°C).
Maximum outdoor operating air temperature is 125°F (51.7°C).
For reliable operation, unit should be level in all horizontal planes.
Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft indoor coil below = 150 ft. (See items 6 and 7
following.)
For interconnecting refrigerant tube lengths of 50 to 175 ft or 20 ft vertical differential, consult Long-Line Application Guideline available from
equipment distributor.
Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.
If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in.
may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
Mismatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort.

—27—

GUIDE SPECIFICATIONS

Air-Cooled, Split-System
Air Conditioner
593C
1-1/2 to 5 Tons Nominal

GENERAL
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air-cooled coil, propeller-type condenser
fan, and a control box. Unit will discharge supply air upward as
shown on contract drawings. Unit will be used in a refrigeration
circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
Unit will be rated in accordance with the latest edition of ARI
Standard 240.
Unit will be certified for capacity and efficiency, and listed in the
latest ARI directory.
Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
Unit will be constructed in accordance with UL standards and will
carry the UL label of approval. Unit will have c-UL approval.
Unit cabinet will be capable of withstanding Federal Test Method
Standard No. 141 (Method 6061) 500-hr salt spray test.
Air-Cooled condenser coils will be leak tested at 150 psig and
pressure tested at 300 psig.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.

PRODUCTS
Equipment
Factory assembled, single piece, air-cooled air conditioner unit.
Contained within the unit enclosure will be all factory wiring, piping, controls, compressor, refrigerant charge (R-22), and special
features required prior to field start-up.
Unit Cabinet
Unit cabinet will be constructed of galvanized steel, bonderized,
and coated with a powder coat paint.
Fans
Condenser fan will be direct-drive propeller type, discharging air
upward.

Condenser fan motors will be totally enclosed, 1-phase type with
class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant.
Fan blades will be statically and dynamically balanced.
Condenser fan openings will be equipped with steel wire safety
guards.
Compressor
Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration isolators.
Condenser Coil
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically bonded to
copper tubes which are then cleaned, dehydrated, and sealed.
Refrigeration Components
Refrigeration circuit components will include liquid-line shutoff
valve with sweat connections, suction tube shutoff valves with
sweat connections, system charge of R-22 (R-410A) refrigerant,
and compressor oil.
Operating Characteristics
The capacity of the unit will meet or exceed
Btuh at a
suction temperature of
°F. The power consumption at full
load will not exceed
kw.
Combination of the unit and the evaporator or fan coil unit will
have a total net cooling capacity of
Btuh or greater at conditions of
CFM entering air temperature at the evaporator
at
°F wet bulb and
°F dry bulb, and air entering the
unit at
°F.
The system will have an SEER of
Btuh/watt or greater at
DOE conditions.
Electrical Requirements
Nominal unit electrical characteristics will be
v, 1 single
phase, 60 hz. The unit will be capable of satisfactory operation
within voltage limits of
v to
v.
Unit electrical power will be single point connection.
Control circuit will be 24v.
Special Features
Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements.

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS

Cancels: PDS 593C.18.6

© 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231

—28—

PRINTED IN U.S.A.

Catalog No. 5259-301

2-03



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 2003:02:21 09:50:22Z
Modify Date                     : 2005:11:14 11:49:17-05:00
Metadata Date                   : 2005:11:14 11:49:17-05:00
Producer                        : Acrobat Distiller 4.05 for Macintosh
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:9929e182-c59a-416e-9535-38ea2b8856d7
Instance ID                     : uuid:8c2dacc9-bd3c-40d9-b9bf-62dc41f4df3d
Page Count                      : 28
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu