Bryant Air Conditioner 116B Users Manual PDS116B 04
Bryant Air Conditioner 116B PDS116B-04
116B to the manual 939eda02-f816-4cbd-9659-06afcae64de4
2015-02-02
: Bryant Bryant-Air-Conditioner-116B-Users-Manual-411802 bryant-air-conditioner-116b-users-manual-411802 bryant pdf
Open the PDF directly: View PDF .
Page Count: 22
Download | |
Open PDF In Browser | View PDF |
116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1--1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Efficiency S 14 -- 16.5 SEER/11.0-- 13.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound S Sound level as low as 76 dBA S Sound level as low as 74 dBA with accessory sound blanket Comfort S System supports Edger Thermidistatt or standard thermostat controls Reliability S Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime servce cost. the environmentally sound refrigerant Bryant’s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 116B has been designed utilizing Bryant’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. This product has been designed and manufactured to meet Energy Starr criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up--to--date ratings information. S Scroll compressor S Internal pressure relief valve S Internal thermal overload S Filter drier S Balanced refrigeration system for maximum reliability Durability DuraGuardt protection package: S Solid, durable sheet metal construction S Dense wire coil guard standard S Baked--on, complete outer coverage, powder paint Applications S Long--line -- up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.) S Low ambient accessory kit (down to --20_F/--28.9_C)) with MODEL NUMBER NOMENCLATURE 1 N 2 N 3 N 4 A 5 A/N 6 N 7 N 8 N 9 N 10 A/N 11 A/N 12 N 14 A 1 1 6 B N A 0 3 6 0 0 0 0 Product Family Tier SEER Major Series Voltage Grille Variations Open Open Open Series B=Puron N= 208--- 230--- 1 or 208/230--- 1 A = Dense 0=Not Defined 0=Not Defined 1=AC 1= Legacy RNC 6=16 SEER Cooling Capacity 0=Not Defined ISO 9001:2000 the environmentally sound refrigerant REGISTERED 116B Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. STANDARD FEATURES Feature 018 024 030 036 042 048 / 049 Puron Refrigerant X X X X X X 060 / 061 X Maximum SEER * 16.0 16.0 16.5 16.5 16.0 16.0 16.0 Scroll Compressor X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Dense Grille X X X X X X X 049--- A 231 (104.8) 269 (222.0) 060--- A 272 (123.4) 310 (140.6) 061--- A 272 (123.4) 310 (140.6) 9.00 (4.08) 14.50 (6.58) 14.50 (6.58) * With approved combinations X = Standard PHYSICAL DATA UNIT SIZE --- VOLTAGE, SERIES Operating Weight lb (kg) Shipping Weight lb (kg) 018--- B 125 (56.7) 154 (69.9) 024--- A 147 (66.5) 183 (82.8) 030--- A 153 (69.3) 188 (85.2) 4.60 (2.09) 6.00 (2.72) 6.81 (3.09) Compressor Type REFRIGERANT Control Charge lb (kg) 036--- A 165 (74.8) 204 (92.5) 042--- A 048--- B 213 264 (96.4) (119.7) 254 317 (115.2) (143.8) Scroll Puron® (R---410A) TXV (Puron® Hard Shutoff) 7.00 8.62 13.0 (3.18) (3.91) (5.90) Propeller Type, Direct Drive Vertical 3223 3810 4046 1/12 1/5 1/4 800 800 800 COND FAN Air Discharge Vertical Air Qty (CFM) 1881 2614 2614 4046 4046 4046 Motor HP 1/12 1/10 1/10 1/4 1/4 1/4 Motor RPM 1100 1100 1100 800 800 800 COND COIL Face Area (Sq ft) 11.50 15.10 17.20 17.60 25.15 25.15 25.15 30.15 30.15 Fins per In. 25 25 25 25 25 20 20 20 20 Rows 1 1 1 1 1 2 1 2 2 Circuits 3 4 4 4 6 7 7 8 8 VALVE CONNECT. (In. ID) Vapor 3/4 3/4 3/4 7/8 7/8 7/8 7/8 7/8 7/8 Liquid 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 REFRIGERANT TUBES (In. OD) Rated Vapor* 3/4 7/8 1 ---1/8 Max Liquid Line { 3/8 * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. Note: See unit Installation Instruction for proper installation. { See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables. 2 REFRIGERANT PIPING LENGTH LIMITATIONS Liquid Line Sizing and Maximum Total Equivalent Lengths{ for Cooling Only Systems with Puronr Refrigerant: The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and outdoor units. See Table below for liquid line sizing and maximum lengths : Maximum Total Equivalent Length Outdoor Unit BELOW Indoor Unit 18000 AC with Puron 3/8 24000 AC with Puron 3/8 30000 AC with Puron 3/8 Liquid Line Diam. w/ TXV 1/4 5/16 3/8 1/4 5/16 3/8 1/4 5/16 3/8 AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor Vertical Separation ft (m) 0--- 5 (0--- 1.5) 6--- 10 (1.8--- 3.0) 11--- 20 (3.4--- 6.1) 21--- 30 (6.4--- 9.1) 31--- 40 (9.4--- 12.2) 41--- 50 (12.5--- 15.2) 51--- 60 (15.5--- 18.3) 61--- 70 (18.6--- 21.3) 71--- 80 (21.6--- 24.4) 150 250* 250* 75 250* 250* 30 175 250* 150 250* 250* 75 250* 250* --- --225* 250* 125 250* 250* 75 250* 250* --- --200 250* 100 250* 250* 50 250* 250* --- --175 250* 100 250* 250* 50 250* 250* --- --125 250* 75 250* 250* --- --225* 250* --- --100 250* --- --250* 250* --- --175 250* --- --75 250* --- --225* 250* --- --125 250* --- ----- --250* --- --150 250* --- --100 250* --- ----- --250* 36000 5/16 175 150 150 100 AC with 3/8 3//8 250* 250* 250* 250* Puron 42000 5/16 125 100 100 75 AC with 3/8 3/8 250* 250* 250* 250* Puron 48000 AC with 3/8 3/8 250* 250* 250* 250* Puron 49000 AC with 3/8 3/8 250* 250* 250* 250* Puron 60000 AC with 3/8 3/8 250* 250* 250* 225* Puron 61000 AC with 3/8 3/8 250* 250* 250* 225* Puron * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line --- --- = outside acceptable range 100 100 75 --- --- --- --- 250* 250* 250* 250* 250* 75 50 --- --- --- --- --- --- 250* 250* 250* 250* 150 250* 250* 230 160 --- --- 250* 250* 230 160 --- --- 190 150 110 --- --- --- --- 190 150 110 --- --- --- --- Guideline for details. Maximum Total Equivalent Length Outdoor Unit ABOVE Indoor Unit Size Liquid Line Connection 18000 AC with Puron 3/8 24000 AC with Puron 3/8 30000 AC with Puron 3/8 Liquid Line Diam. w/ TXV 1/4 5/16 3/8 1/4 5/16 3/8 1/4 5/16 3/8 AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor Vertical Separation ft (m) 25 (7.6) 26--- 50 (7.9--- 15.2) 51--- 75 (15.5--- 22.9) 76--- 100 (23.2--- 30.5) 101--- 125 (30.8--- 38.1) 126--- 150 (38.4--- 45.7) 151--- 175 (46.0--- 53.3) 176--- 200 (53.6--- 61.0) 175 250* 250* 100 250* 250* 30 250* 250* 250* 250* 250* 125 250* 250* --- --250* 250* 250* 250* 250* 175 250* 250* --- --250* 250* 250* 250* 250* 200 250* 250* --- --250* 250* 250* 250* 250* 225* 250* 250* --- --250* 250* 250* 250* 250* 250* 250* 250* --- --250* 250* 250* 250* 250* 250* 250* 250* --- --250* 250* 250* 250* 250* 250* 250* 250* --- --250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 250* 36000 5/16 225* 250* 250* 250* 250* 3/8 AC with 3/8 250* 250* 250* 250* 250* Puron 42000 5/16 175 200 250* 250* 250* AC with 3/8 3/8 250* 250* 250* 250* 250* Puron 48000 3/8 3/8 250* 250* 250* 250* 250* AC with Puron 49000 AC with 3/8 3/8 250* 250* 250* 250* 250* Puron 60000 AC with 3/8 3/8 250* 250* 250* 250* 250* Puron 61000 AC with 3/8 3/8 250* 250* 250* 250* 250* Puron * Maximum actual length not to exceed 200 ft (61 m) { Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details. --- --- = outside acceptable range 3 116B Size Liquid Line Connection REFRIGERANT CHARGE ADJUSTMENTS Liquid Line Size Puron Charge oz/ft 3/8 0.60 (Factory charge for lineset = 9 oz) 5/16 0.40 1/4 0.27 116B Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines, charge adjustments are required per the chart above. Charging Formula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz. Net result is to remove 4.95 oz of refrigerant from the system Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment? Formula: (.40 oz/ft. x 45ft) – (9 oz.) = 9 oz. Net result is to add 9 oz of refrigerant to the system LONG LINE APPLICATIONS An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units. For Air Conditioner systems, the chart below shows when an application is considered Long Line. AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size 1/4 Units On Same Level No accessories needed within allowed lengths Outdoor Below Indoor No accessories needed within allowed lengths Outdoor Above Indoor 175 (53.3) 5/16 120 (36.6) 50 (15.2) 120 (36.6) 3/8 80 (24.4) 35 (10.7) 80 (24.4) Note: See Long Line Guideline for details VAPOR LINE SIZING AND COOLING CAPACITY LOSS Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line diameters shown in the chart below are acceptable for AC systems with Puron refrigerant: Unit Nominal Size (Btuh) 18000 1 Stage AC with Puron 24000 1 Stage AC with Puron 30000 1 Stage AC with Puron 36000 1 Stage AC with Puron 42000 1 Stage AC with Puron 48000, 49000 1 Stage AC with Puron 60000, 61000 1 Stage AC with Puron Maximum Liquid Line Diameters (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 Vapor Line Diameters (In. OD) 26--- 50 51--- 80 81--- 100 (7.9--- 15.2) (15.5--- 24.4) (24.7--- 30.5) 1/2 1 2 5/8 0 1 3/4 0 5/8 Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) 101--- 125 126--- 150 151--- 175 176--- 200 201--- 225 226--- 250 (30.8--- 38.1) (38.4--- 45.7) (46.0--- 53.3) (53.6--- 61.0) (61.3--- 68.6) (68.9--- 76.2) 3 5 6 7 8 9 11 1 1 2 2 2 3 3 0 0 0 1 1 1 1 1 0 1 2 2 3 3 4 5 5 3/4 0 0 1 1 1 1 1 2 2 7/8 0 0 0 0 0 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 8 9 10 12 3/4 0 1 1 2 2 3 3 4 4 7/8 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 3 4 4 5 6 7/8 0 0 1 1 1 2 2 2 3 1 1/8 0 0 0 0 0 0 0 0 0 3/4 0 1 2 3 4 5 5 6 7 3 7/8 0 0 1 1 2 2 2 3 1 1/8 0 0 0 0 0 0 0 1 1 3/4 1 2 4 5 6 7 9 10 11 7/8 0 1 2 2 3 4 4 5 5 1 1/8 0 0 0 1 1 1 1 1 1 Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline. 4 ACCESSORY THERMOSTATS PART NUMBER PROGRAM GAS ELECTRIC HEAT COOL T2 ---PAC01 5 ---2 Day √ √ 1 1 T2 ---NAC01 NP √ √ 1 1 T2SNAC01 NP √ 1 1 √ THERMOSTAT ACCESSORIES PART NUMBER BRIEF DESCRIPTION THERMOSTATS USED WITH TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wire) --- 10 pack All Bryantr branded thermostats TX ---LBP01 Large Decorative Backplate T6 ---Pxx, T6 ---Nxx, and T2 ---Pxx TX ---MBP01 Medium Decorative Backplate T2 ---Nxx and T1 ---Pxx ACCESSORIES DESCRIPTION Unit Sizes --- Series 018--- B 024--- A 030--- A 036--- A 042--- A 048--- B 049--- A 060--- A 061--- A KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X X X KAATD0101TDR TIME DELAY RELAY X X X X X X X X X KSALA0301410 LOW AMBIENT PSW X X X X X X X X X KSALA0601AAA{ MOTORMASTER 230V X X X X X X X X X HC32GE234 MOTOR FAN BALL BEARING X HC34GE240 MOTOR FAN BALL BEARING X X HC32GE229 MOTOR FAN BALL BEARING HC38GE228 MOTOR FAN BALL BEARING HC40GE228 MOTOR FAN BALL BEARING X X X X KSAHS1701AAA HARD START (CAP / RELAY) X X X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X X X KAACS0201PTC START ASSIST PTC X X X X X X X X X KAALS0201LLS LIQUID LINE SOLENOID X X X X X X X X X KAAWS0101AAA WINTER START X X X X X X X X X KAACH1701AAA CRANKCASE HTR X X X X KAACH1601AAA CRANKCASE HTR X S S S S KSATX0201PUR TXV PURON HSO X X X KSATX0301PUR TXV PURON HSO KSATX0401PUR TXV PURON HSO KSATX0501PUR TXV PURON HSO X X KSASH0601COP SOUND HOOD KSASH2101COP SOUND HOOD KAALP0401PUR KAAHI0501PUR X X X X X X X X X X X X X X X LOW PRESSURE SWITCH X X X X X X X X X HIGH PRESSURE SWITCH X X X X X X X X X { Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, hard shut---off TXV. X = Accessory / S --- Standard 5 116B KIT NUMBER ACCESSORY USAGE GUIDELINE ACCESSORY Ball Bearing Fan Motor Compressor Start Assist Capacitor and Relay Crankcase Heater Evaporator Freeze Thermostat Hard Shut---Off TXV Liquid Line Solenoid Valve Motor Master® Control or Low---ambient Pressure Switch Support Feet Winter Start Control Yes{ Yes Yes Yes Yes No REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft./24.38 m) No Yes Yes No Yes No REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles/3.22 km) No No No No Yes No Yes No No Recommended Yes No No Recommended No REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS (Below 55°F/12.8_C) 116B * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Accessory Description and Usage (Listed Alphabetically) 1. Ball--Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMasterr is used. 2. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a ”hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a ”soft” boost to the compressor at each start--up. Usage Guideline: Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Cycle Protector The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5--minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling. 6. Evaporator Freeze Thermostat An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Usage Guideline: Required when low ambient kit has been added. 7. Low--Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low--ambient temperatures down to 0_F (--18_C) when properly installed. Usage Guideline: A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 8. MotorMasterr Low--Ambient Controller A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 5.5_C). Usage Guideline: A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 9. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 6 Accessory Description and Usage (Listed Alphabetically) (Continued) 13. Time--Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to AHRI Unitary Directory. 14. Winter Start Control This control is designed to alleviate nuisance opening of the low--pressure switch by bypassing it for the first 3 minutes of operation. 116B 10. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart. 11. Support Feet Four stick--on plastic feet that raise the unit 4 in. (101.6 mm) above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Usage Guideline: Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 12. Thermostatic Expansion Valve (TXV) A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve AHRI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 7 ELECTRICAL DATA OPER VOLTS* UNIT SIZE MAX MIN LRA MCA MIN WIRE SIZE{ 60° C MIN WIRE SIZE{ 75° C MAX LENGTH ft. (m)} 60° C FAN RLA FLA MAX LENGTH ft. (m)} 75° C MAX FUSE** or CKT BRK AMPS 018--- B 48.0 9.0 0.50 11.8 14 14 67 (20.4) 64 (19.5) 20 024--- A 58.3 13.5 0.75 17.7 14 14 46 (14.0) 43 (13..1) 25 030--- A 64.0 12.8 0.75 16.8 14 14 44 (13.4) 41 (12.5) 25 036--- A 77.0 14.1 0.50 18.1 12 12 57 (17.4) 54 (16.5) 30 112.0 17.9 1.20 23.6 10 10 85 (25.9) 81 (24.7) 40 048--- B 109.0 19.9 1.20 26.1 10 10 70 (21.3) 67 (20.4) 40 049--- A 117.0 21.8 1.20 26.1 10 10 70 (21.3) 67 (20.4) 40 060--- A 135.0 21.4 1.20 28.0 8 10 91 (27.7) 56 (17.1) 40 042--- A 116B COMPR V/PH 208/230/1 ---60 253 197 061--- A 134.0 25.0 1.20 32.5 8 10 94 (28.7) 58 (17.7) 50 * Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 334 ---80. If other than uncoated (no ---plated), 60 or 75_C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70). } Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time ---Delay fuse. FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. Complies with 2007 requirements of ASHRAE Standards 90.1 A--WEIGHTED SOUND POWER LEVEL (dBA) Unit Size --Voltage, Series Standard Rating (dBA) 0018--- B 0024--- A 0030--- A 0036--- A 0042--- A 0048--- B 0049--- A 0060--- A 0061--- A 76 76 76 76 78 78 78 78 78 125 52.5 57.5 55.0 50.5 52.5 57.5 51.5 55.0 56.5 TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 250 500 1000 2000 4000 59.0 65.5 70.5 64.5 59.0 64.0 69.0 71.0 69.0 64.5 63.5 68.0 69.5 67.0 63.5 59.5 64.5 70.5 62.0 59.5 62.0 66.0 73.5 68.0 62.0 61.5 66.0 70.5 65.5 59.5 62.0 67.5 73.5 69.0 64.5 62.5 67.5 70.5 65.0 61.0 63.0 65.5 69.0 67.0 61.5 8000 54.5 60.0 58.5 54.5 55.5 53.5 62.0 53.5 56.0 NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI). A--WEIGHTED SOUND POWER LEVEL (dBA) WITH SOUND SHIELD Unit Size --Voltage, Series Standard Rating (dBA) 0018--- B 0024--- A 0030--- A 0036--- A 0042--- A 0048--- B 0049--- A 0060--- A 0061--- A 74 75 75 74 76 76 76 75 75 125 55.5 58.0 55.5 51.5 53.0 58.5 53.0 56.5 57.0 TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment) 250 500 1000 2000 4000 59.0 65.0 68.5 63.5 58.0 64.0 69.0 70.5 68.5 64.5 63.0 68.0 69.0 67.0 63.0 58.5 62.0 65.0 61.0 58.0 62.0 65.5 72.0 65.0 61.0 61.5 66.0 69.0 64.0 58.5 61.5 67.5 72.0 68.0 61.5 62.5 66.5 68.0 63.0 59.5 63.0 65.5 67.0 65.5 59.0 NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI). CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE --- VOLTAGE, SERIES 018--- B 024--- A 030--- A 036--- A 042--- A 048--- B 049--- A 060--- A 061--- A REQUIRED SUBCOOLING _F (_C) 10 (5.6) 10 (5.6) 10 (5.6) 10 (5.6) 9 (5.0) 10 (5.6) 8 (4.4) 9 (5.0) 9 (5.0) 8 8000 52.0 59.5 58.5 52.0 54.0 51.0 59.0 51.5 52.5 9 A A A A A A B A B A 116BNA024 116BNA030 116BNA036 116BNA042 116BNA048 116BNA060 116BNA018 116BNA061 116BNA048 116BNA049 O O O O O O O O O O O O O O O O O O O O O O 3 7/8" 3 7/8" 28 5/16" 32 5/16" 28 5/16" 39 1/8" 32 5/16" 45 15/16" 28 11/16" 45 15/16" 39 1/8" 39 1/8" 31 3/16" 35" 35" 35" 35" 25 3/4" 35" 35" 35" 35" X 35" 26" X 26" 31 1/2" X 31 1/2" 24,30 X = YES O = NO 3 3/4" 28 11/16" 23 1/8" 31 3/16" SQ. A 7/8" 7/8" 7/8" 3/4" 7/8" 7/8" 7/8" 7/8" 3/4" 3/4" 3/4" D AIR DISCHARGE 3 7/8" 3 7/8" 3 7/8" 3 3/4" 3 7/8" 3 7/8" 3 3/4" 3 3/4" C A B MINIMUM MOUNTING PAD DIMENSIONS 36, 48, 49, 60, 61 18 3 1/2" DVAPOR LINE CONN. C 3/8" LIQUID LINE CONN. FIELD POWER SUPPLY CONN. 7/8" HOLE WITH 1 1/8" KNOCKOUT FIELD CONTROL SUPPLY CONN. 7/8" HOLE O O O O O O O O O O O X X X X X X X X X X X 208-230-1-60 UNIT SIZE B A 116BNA018 ELECTRICAL CHARACTERISTICS 230-1-60 SERIES 208/230-3-60 UNIT DIMENSIONS -- ENGLISH 460-3-60 6 9/16" 6 9/16" 6 9/16" 4 7/16" 6 9/16" 6 9/16" 6 9/16" 6 9/16" 6 9/16" 6 9/16" 4 7/16" E 28 7/16" 28 7/16" 28 7/16" 21 1/4" 28 7/16" 28 7/16" 28 7/16" 28 7/16" 24 11/16" 24 11/16" 18 1/16" F 1 7/8" 9 1/8" 9 1/8" 9 1/8" 7 13/16" 9 1/8" 9 1/8" 9 1/8" 9 1/8" 9 1/8" 9 1/8" 7 13/16" G P 2 15/16" 2 15/16" 2 15/16" 2 13/16" 2 15/16" 2 15/16" 2 15/16" 2 15/16" 2 13/16" 2 13/16" 2 13/16" K 3" AIR IN 5/16" 17 1/2" 16 1/2" 16 1/2" 13 5/8" 16 1/2" 17" 16 1/2" 16" 15 1/2" 16" 13" M K 16 1/2" 16 1/2" 17" 13 1/2" 17" 17 1/2" 17 1/2" 16" 16" 16" 12" N 3/8" TIEDOWN KNOCKOUTS (2) PLACES L 5/8" 5/8" 5/8" 1/2" 5/8" 5/8" 5/8" 5/8" 1/2" 1/2" 1/2" L G M 15" 15" 16 1/4" 12 3/4" 16 1/4" 14 1/4" 17 1/2" 13" 14 1/4" 13" 13" P 116B AIR IN AIR IN 231 264 272 125 272 231 213 165 153 147 118 AIR DISCHARGE 269 317 310 154 310 274 254 204 188 183 141 OPERATING SHIPPING WEIGHT (lbs) WEIGHT (lbs) E N F 36 1/8" X 39 5/16" X 42 3/4" 36 1/8" X 39 5/16" X 42 3/4" 36 1/8" X 39 15/16" X 49 9/16" 26 7/8" X 30 1/16" X 32 9/16" 36 1/8" X 39 5/16" X 49 9/16" 36 1/8" X 39 5/16" X 35 15/16" 36 1/8" X 39 5/16" X 42 3/4" 36 1/8" X 39 5/16" X 32 9/16" 32 3/8" X 35 1/2" X 35 15/16" 32 3/8" X 35 1/2" X 32 9/16" 24 1/4" X 27 3/8" X 32 9/16" AIR IN SHIPPING DIMENSIONS (L x W x H) 10 A A A A A A B A B A 116BNA024 116BNA030 116BNA036 116BNA042 116BNA048 116BNA060 116BNA018 116BNA061 116BNA048 116BNA049 O O O O O O O O O O O O O O O O O O O O O O 88.9 993.8 889.0 660.4 X 660.4 800.1 X 800.1 889.0 X 889.0 18 24,30 36, 48, 49, 60, 61 X = YES O = NO 719.2 889.0 728.7 1166.8 993.8 993.8 654.0 889.0 889.0 889.0 820.8 820.8 792.2 1166.8 719.2 792.2 889.0 728.7 587.3 889.0 B A MINIMUM MOUNTING PAD DIMENSIONS DVAPOR LINE CONN. C 9.53 LIQUID LINE CONN. FIELD POWER SUPPLY CONN. 22.23 HOLE WITH 28.58 KNOCKOUT FIELD CONTROL SUPPLY CONN. 22.23 HOLE O O O O O O O O O O O X X X X X X X X X X X 208-230-1-60 UNIT SIZE B A 116BNA018 ELECTRICAL CHARACTERISTICS 230-1-60 SERIES 208/230-3-60 UNIT DIMENSIONS -- SI 460-3-60 SQ. A 22.2 22.2 22.2 19.0 22.2 22.2 22.2 22.2 19.0 19.0 19.0 D AIR DISCHARGE 98.6 98.6 98.6 95.2 98.6 98.6 98.6 98.6 95.2 95.2 95.2 C 166.7 166.7 166.7 112.7 166.7 166.7 166.7 166.7 166.7 166.7 112.7 E 722.3 722.3 722.3 539.8 722.3 722.3 722.3 722.3 627.1 627.1 458.8 F 47.6 231.8 231.8 231.8 198.4 231.8 231.8 231.8 231.8 231.8 231.8 198.4 G P 74.6 74.6 74.6 71.4 74.6 74.6 74.6 74.6 71.4 71.4 71.4 K 76.2 L AIR IN 8.0 444.5 419.1 419.1 346.1 419.1 431.8 419.1 406.4 393.7 406.4 330.2 M K 419.1 419.1 431.8 342.9 431.8 444.5 444.5 406.4 406.4 406.4 304.8 N 9.53 TIEDOWN KNOCKOUTS (2) PLACES 15.9 15.9 15.9 12.7 15.9 15.9 15.9 15.9 12.7 12.7 12.7 L G M 381.0 381.0 412.8 323.9 412.8 362.0 444.5 330.2 362.0 330.2 330.2 P AIR IN AIR IN 104.8 119.7 123.4 56.7 123.4 104.8 96.4 74.8 69.3 66.5 53.4 AIR DISCHARGE 122.0 143.8 140.6 69.9 140.6 124.3 115.2 92.5 85.2 82.8 64.0 OPERATING SHIPPING WEIGHT (Kgs) WEIGHT (Kgs) 116B E N F 917.6 X 998.6 X 1085.8 917.6 X 998.6 X 1085.8 917.6 X 998.6 X 1258.9 682.6 X 763.6 X 827.1 917.6 X 998.6 X 1258.9 917.6 X 998.6 X 912.8 917.6 X 998.6 X 1085.8 917.6 X 998.6 X 827.1 822.3 X 901.7 X 912.8 822.3 X 901.7 X 827.1 616.0 X 695.3 X 827.1 AIR IN SHIPPING DIMENSIONS (L x W x H) 11 24” (609.6) Service 12” (304.8) Note: Numbers in ( ) = mm 18” (457.2) 24” (609.6) Service Wall 6” (152.4) 18” (457.2) 12” (304.8) 24” (609.6) Service Wall 18” (457.2) 12” (304.8) Clearances (various examples) 24” (609.6) Service 12” (304.8) 24” (609.6) Service Wall 6” (152.4) 116B IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air. CLEARANCES Wall TESTED AHRI COMBINATION RATINGS* NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Bryant database at: http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/ 116B Model Number 116BNA018****B 116BNA024****A 116BNA030****A 116BNA036****A 116BNA042****A 116BNA048****B 116BNA049****A 116BNA060****A 116BNA061****A Indoor Coil Model Number CNPV*1917A** CNPV*3117A** CNPV*3117A** CNPV*3717A** CNPV*4324A** CAP**6025A** CAP**6025A** CNPV*6124A** CNPV*6124A** Furnace Model Number Cooling Capacity 18,000 23,600 28,600 34,400 41,500 46,000 48,000 56,000 59,500 EER 12.0 12.0 12.0 12.0 12.0 12.0 11.5 12.0 12.0 SEER 14.5 14.5 14.5 14.5 14.5 14.5 14.0 14.5 14.5 * AHRI = Air Conditioning, Heating & Refrigeration Institute EER — Energy Efficiency Ratio SEER — Seasonal Energy Efficiency Ratio NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are affected. 12 13 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) See notes on pg. 17 900 800 700 CFM EWB ° F (° C) EVAPORATOR AIR 675 600 525 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 10.39 12.69 12.20 14.92 17.19 10.93 13.55 13.02 16.11 17.99 11.45 14.38 13.79 18.68 18.66 Sens‡ 28.21 25.63 23.72 23.32 22.68 28.72 26.16 24.23 23.91 23.70 29.09 26.54 24.61 24.60 24.56 Total 13.70 16.78 16.13 19.80 22.68 14.43 17.95 17.22 21.38 23.70 15.12 19.08 18.27 24.60 24.56 Sens‡ Capacity MBtuh† 21.52 19.59 18.14 17.80 17.19 21.94 19.99 18.55 18.25 17.99 22.24 20.29 18.85 18.68 18.66 Total Capacity MBtuh† 75 (23.9) 1.55 1.55 1.55 1.55 1.55 1.58 1.58 1.58 1.58 1.58 1.62 1.62 1.62 1.62 1.62 Total System KW** 1.18 1.18 1.18 1.18 1.18 1.21 1.20 1.20 1.20 1.20 1.23 1.23 1.23 1.23 1.23 Total System KW** 85 (29.4) 85 (29.4) 10.05 12.32 11.84 14.56 16.54 10.58 13.19 12.65 15.72 17.28 11.09 14.01 13.42 17.93 17.90 Sens‡ 26.92 24.44 22.62 22.25 21.84 27.38 24.91 23.08 22.85 22.79 27.72 25.25 23.42 23.62 23.59 Total 13.25 16.32 15.67 19.34 21.84 13.97 17.49 16.75 22.74 22.79 14.67 18.60 17.79 23.62 23.59 Sens‡ Capacity MBtuh† 20.55 18.66 17.28 16.97 16.54 20.92 19.03 17.64 17.39 17.28 21.19 19.30 17.91 17.93 17.90 Total Capacity MBtuh† DETAILED COOLING CAPACITIES# 1.65 1.64 1.63 1.63 1.63 1.68 1.67 1.66 1.66 1.66 1.71 1.70 1.69 1.69 1.69 116B CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh† Capacity MBtuh† System System System Total Sens‡ Total Sens‡ KW** KW** KW** 116BNA024****A Outdoor Section With CNPV*3117A** Indoor Section 1.74 25.54 12.78 1.94 24.09 12.29 2.16 1.73 23.19 15.85 1.93 21.87 15.36 2.15 1.73 21.46 15.20 1.92 20.22 14.70 2.14 1.73 21.14 18.86 1.92 20.00 19.96 2.14 1.73 20.93 20.93 1.92 19.96 19.96 2.14 1.77 25.95 13.49 1.98 24.44 12.99 2.20 1.77 23.60 17.00 1.97 22.22 16.49 2.19 1.77 21.86 16.27 1.96 20.58 15.76 2.18 1.77 21.85 21.85 1.96 20.81 20.81 2.18 1.76 21.82 21.82 1.96 20.78 20.78 2.18 1.81 26.23 14.18 2.02 24.68 13.67 2.24 1.81 23.90 18.11 2.01 22.48 17.59 2.22 1.80 22.16 17.30 2.00 20.84 16.78 2.22 1.80 22.58 22.58 2.00 21.48 21.48 2.22 1.80 22.55 22.55 2.00 21.45 21.45 2.22 116BNA018****B Outdoor Section With CNPV*1917A** Indoor Section 1.32 19.48 9.68 1.48 18.35 9.29 1.32 17.68 11.95 1.47 16.64 11.56 1.32 16.37 11.47 1.47 15.40 11.07 1.31 16.08 14.18 1.47 15.17 13.78 1.31 15.84 15.84 1.46 15.09 15.09 1.35 19.82 10.21 1.51 18.63 9.81 1.35 18.00 12.80 1.50 16.92 12.40 1.34 16.68 12.26 1.49 15.68 11.86 1.34 16.55 16.55 1.49 15.74 15.74 1.34 16.53 16.53 1.49 15.72 15.72 1.38 20.06 10.72 1.54 18.83 10.32 1.37 18.24 13.62 1.53 17.13 13.22 1.37 16.92 13.03 1.52 15.88 12.61 1.37 17.12 17.12 1.52 16.26 16.26 1.37 17.09 17.09 1.52 16.24 16.24 Total System KW** CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 115 (46.1) 115 (46.1) 8.88 11.14 10.66 14.30 14.27 9.40 11.98 11.44 14.87 14.85 9.90 12.79 12.18 15.33 15.31 Sens‡ 22.56 20.47 18.91 18.95 18.92 22.85 20.76 19.21 19.69 19.66 23.05 20.98 19.45 20.29 20.27 Total 11.77 14.84 14.18 18.95 18.92 12.47 15.96 15.22 19.69 19.66 13.15 17.05 16.23 20.29 20.27 Sens‡ Capacity MBtuh† 17.15 15.54 14.37 14.30 14.27 17.39 15.78 14.60 14.87 14.85 17.55 15.95 14.78 15.33 15.31 Total Capacity MBtuh† 2.41 2.39 2.38 2.38 2.38 2.44 2.43 2.42 2.42 2.43 2.48 2.47 2.46 2.47 2.47 Total System KW** 1.84 1.83 1.82 1.82 1.82 1.87 1.86 1.85 1.85 1.85 1.90 1.89 1.88 1.88 1.88 Total System KW** 125 (51.7) 125 (51.7) 8.46 10.72 10.22 13.42 13.40 8.97 11.54 10.99 13.93 13.91 9.47 12.34 11.73 14.35 14.33 Sens‡ 20.94 18.98 17.52 17.82 17.79 21.17 19.23 17.78 18.49 18.46 21.32 19.42 17.98 19.02 18.99 Total 11.24 14.29 13.62 17.82 17.79 11.93 15.41 14.66 18.49 18.46 12.60 16.48 15.65 19.02 18.99 Sens‡ Capacity MBtuh† 15.88 14.37 13.27 13.42 13.40 16.07 14.57 13.47 13.93 13.91 16.20 14.72 13.63 14.35 14.33 Total Capacity MBtuh† 2.68 2.67 2.67 2.67 2.67 2.72 2.71 2.70 2.71 2.71 2.76 2.75 2.74 2.75 2.75 Total System KW** 2.06 2.05 2.04 2.04 2.04 2.09 2.08 2.07 2.07 2.07 2.12 2.10 2.10 2.10 2.10 Total System KW** 14 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) EWB ° F (° C) See notes on pg. 17 1350 1200 1050 CFM EVAPORATOR AIR 1125 1000 875 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 16.61 20.47 19.68 24.28 27.76 17.49 21.88 20.99 28.77 28.93 18.33 23.24 22.25 29.93 29.89 Sens‡ 41.06 37.33 34.65 34.09 33.38 41.77 38.02 35.31 34.94 34.80 42.28 38.51 35.80 36.01 35.96 Total 20.24 24.93 23.97 29.55 33.38 21.32 26.65 25.57 31.83 34.80 22.34 28.29 27.10 36.01 35.96 Sens‡ Capacity MBtuh† 34.09 30.99 28.76 28.31 27.76 34.67 31.55 29.30 29.03 28.93 35.09 31.96 29.70 29.93 29.89 Total Capacity MBtuh† 75 (23.9) 2.39 2.37 2.36 2.36 2.35 2.45 2.43 2.42 2.42 2.42 2.52 2.50 2.48 2.48 2.48 Total System KW** 1.91 1.92 1.93 1.93 1.93 1.96 1.97 1.97 1.97 1.97 2.00 2.01 2.02 2.02 2.02 Total System KW** 85 (29.4) 16.09 19.95 19.16 23.74 26.76 16.96 21.35 20.46 27.89 27.84 17.80 22.70 21.71 28.78 28.74 Sens‡ 39.22 35.65 33.08 32.58 32.16 39.84 36.25 33.66 33.53 33.47 40.29 36.70 34.11 34.61 34.56 Total 19.60 24.28 23.32 28.89 32.16 20.66 25.99 24.91 33.53 33.47 21.68 27.62 26.43 34.61 34.56 Sens‡ Capacity MBtuh† 32.58 29.61 27.47 27.08 26.76 33.09 30.10 27.95 27.89 27.84 33.45 30.47 28.32 28.78 28.74 Total Capacity MBtuh† 85 (29.4) 116BNA036****A Outdoor Section With CNPV*3717A** Indoor Section 2.65 37.27 18.94 2.95 35.20 18.24 2.63 33.87 23.61 2.93 31.96 22.90 2.62 31.40 22.64 2.92 29.62 21.92 2.62 31.00 28.17 2.91 29.47 29.47 2.62 30.85 30.85 2.91 29.43 29.43 2.72 37.82 19.99 3.01 35.67 19.28 2.70 34.40 25.30 2.99 32.44 24.58 2.69 31.93 24.22 2.98 30.09 23.48 2.69 32.12 32.12 2.98 30.60 30.60 2.68 32.07 32.07 2.98 30.55 30.55 2.78 38.19 20.99 3.08 35.98 20.27 2.76 34.80 26.93 3.05 32.78 26.19 2.75 32.32 25.72 3.04 30.43 24.97 2.75 33.12 33.12 3.05 31.51 31.51 2.75 33.08 33.08 3.04 31.47 31.47 Total System KW** 3.28 3.26 3.25 3.25 3.25 3.35 3.32 3.31 3.32 3.32 3.41 3.39 3.38 3.38 3.38 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh† Capacity MBtuh† System System System Total Sens‡ Total Sens‡ KW** KW** KW** 116BNA030****A Outdoor Section With CNPV*3117A** Indoor Section 2.11 31.00 15.56 2.33 29.32 15.00 2.59 2.12 28.16 19.41 2.34 26.61 18.84 2.59 2.12 26.11 18.61 2.34 24.65 18.03 2.59 2.12 25.80 23.16 2.34 24.56 24.56 2.59 2.12 25.69 25.69 2.34 24.52 24.52 2.59 2.15 31.45 16.42 2.38 29.71 15.86 2.63 2.16 28.60 20.80 2.38 27.00 20.22 2.64 2.17 26.55 19.90 2.39 25.04 19.31 2.64 2.16 26.74 26.74 2.39 25.50 25.50 2.64 2.16 26.70 26.70 2.39 25.46 25.46 2.64 2.20 31.76 17.25 2.42 29.97 16.67 2.68 2.21 28.93 22.14 2.43 27.29 21.54 2.68 2.21 26.87 21.14 2.43 25.32 20.53 2.69 2.21 27.57 27.57 2.43 26.26 26.26 2.68 2.21 27.53 27.53 2.43 26.22 26.22 2.68 DETAILED COOLING CAPACITIES# (CONT.) 116B 115 (46.1) 115 (46.1) 14.40 18.23 17.41 23.28 23.25 15.25 19.60 18.68 24.14 24.11 16.06 20.90 19.88 24.83 24.80 Sens‡ 33.01 29.95 27.73 27.95 27.91 33.39 30.35 28.13 28.97 28.93 33.65 30.65 28.44 29.80 29.76 Total 17.50 22.15 21.17 27.95 27.91 18.53 23.82 22.71 28.97 28.93 19.52 25.41 24.18 29.80 29.76 Sens‡ Capacity MBtuh† 27.51 24.93 23.07 23.28 23.25 27.83 25.27 23.40 24.14 24.11 28.04 25.52 23.66 24.83 24.80 Total Capacity MBtuh† 3.66 3.65 3.64 3.64 3.64 3.73 3.71 3.70 3.70 3.70 3.79 3.77 3.76 3.77 3.77 Total System KW** 2.88 2.88 2.88 2.88 2.88 2.93 2.93 2.93 2.93 2.93 2.97 2.97 2.98 2.97 2.97 Total System KW** 125 (51.7) 125 (51.7) 13.76 17.56 16.73 21.87 21.83 14.60 18.92 17.98 22.64 22.61 15.41 20.20 19.15 23.26 23.23 Sens‡ 30.65 27.79 25.71 26.29 26.25 30.96 28.13 26.05 27.21 27.17 31.16 28.39 26.32 27.94 27.91 Total 16.73 21.36 20.37 26.29 26.25 17.75 23.01 21.89 27.21 27.17 18.72 24.57 23.32 27.94 27.91 Sens‡ Capacity MBtuh† 25.53 23.10 21.33 21.87 21.83 25.79 23.39 21.63 22.64 22.61 25.96 23.62 21.87 23.26 23.23 Total Capacity MBtuh† 4.11 4.09 4.09 4.09 4.09 4.17 4.15 4.15 4.15 4.15 4.23 4.22 4.21 4.21 4.21 Total System KW** 3.22 3.22 3.22 3.21 3.21 3.26 3.26 3.26 3.26 3.26 3.31 3.31 3.31 3.31 3.31 Total System KW** 15 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) EWB ° F (° C) See notes on pg. 17 1800 1600 1400 CFM EVAPORATOR AIR 1575 1400 1225 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 24.05 29.64 28.52 35.16 40.45 25.29 31.63 30.38 37.80 42.10 26.46 33.54 32.15 43.52 43.46 Sens‡ 55.71 50.48 46.73 45.93 45.05 56.66 51.35 47.56 47.06 46.92 57.33 51.99 48.17 48.51 48.45 Total 27.90 34.32 32.94 40.65 45.05 29.33 36.61 35.07 46.71 46.92 30.68 38.81 37.10 48.51 48.45 Sens‡ Capacity MBtuh† 49.58 45.17 41.97 41.32 40.45 50.40 45.95 42.74 42.31 42.10 50.98 46.53 43.31 43.52 43.46 Total Capacity MBtuh† 75 (23.9) 2.67 2.83 2.93 2.94 2.96 2.72 2.88 2.99 3.00 3.00 2.77 2.94 3.06 3.04 3.04 Total System KW** 2.77 2.75 2.74 2.74 2.73 2.85 2.82 2.81 2.81 2.81 2.92 2.90 2.88 2.88 2.88 Total System KW** 85 (29.4) 23.28 28.86 27.75 34.36 38.96 24.50 30.84 29.59 40.55 40.50 25.66 32.73 31.35 41.82 41.76 Sens‡ 52.91 47.96 44.44 43.75 43.28 53.70 48.71 45.15 45.06 44.99 54.27 49.25 45.68 46.44 46.38 Total 26.91 33.34 31.98 39.65 43.28 28.32 35.62 34.09 45.06 44.99 29.65 37.79 36.10 46.44 46.38 Sens‡ Capacity MBtuh† 47.31 43.10 40.06 39.49 38.96 48.02 43.80 40.75 40.55 40.50 48.52 44.31 41.25 41.82 41.76 Total Capacity MBtuh† 85 (29.4) 116BNA048****B Outdoor Section With CAP**6024* Indoor Section 3.09 50.01 25.90 3.52 47.00 24.87 3.22 45.37 32.35 3.61 42.67 31.33 3.29 42.06 31.01 3.66 39.59 30.00 3.30 41.55 41.29 3.66 39.51 39.51 3.31 41.43 41.43 3.66 39.45 39.45 3.15 50.67 27.29 3.59 47.54 26.24 3.28 46.00 34.60 3.68 43.20 33.56 3.36 42.68 33.09 3.74 40.11 32.06 3.36 43.04 43.04 3.73 40.91 40.91 3.36 42.98 42.98 3.73 40.85 40.85 3.22 51.13 28.60 3.66 47.88 27.53 3.35 46.46 36.75 3.76 43.57 35.67 3.44 43.11 35.07 3.82 40.47 34.01 3.41 44.29 44.29 3.79 42.02 42.02 3.42 44.24 44.24 3.79 41.97 41.97 Total System KW** 116B 3.95 4.01 4.05 4.04 4.04 4.03 4.09 4.13 4.12 4.12 4.11 4.17 4.21 4.19 4.19 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh† Capacity MBtuh† System System System Total Sens‡ Total Sens‡ KW** KW** KW** 116BNA042****A Outdoor Section With CNPV*4324A** Indoor Section 3.07 44.88 22.46 3.42 42.30 21.59 3.80 3.05 40.90 28.04 3.38 38.55 27.18 3.76 3.03 38.02 26.93 3.36 35.83 26.06 3.74 3.03 37.56 33.49 3.36 35.65 35.65 3.74 3.03 37.34 37.34 3.36 35.60 35.60 3.74 3.15 45.48 23.66 3.49 42.82 22.79 3.87 3.12 41.50 30.00 3.46 39.07 29.12 3.84 3.10 38.61 28.75 3.44 36.36 27.87 3.82 3.10 38.82 38.82 3.44 36.94 36.94 3.82 3.10 38.76 38.76 3.44 36.89 36.89 3.82 3.22 45.91 24.82 3.56 43.16 23.93 3.95 3.19 41.95 31.88 3.53 39.45 30.98 3.91 3.17 39.06 30.49 3.51 36.74 29.58 3.89 3.18 39.96 39.96 3.52 37.98 37.98 3.90 3.18 39.91 39.91 3.52 37.93 37.93 3.90 DETAILED COOLING CAPACITIES# (CONT.) 115 (46.1) 115 (46.1) 20.70 26.27 25.16 33.78 33.73 21.88 28.20 26.94 34.93 34.89 23.01 30.02 28.62 35.86 35.81 Sens‡ 43.85 39.85 36.99 37.39 37.34 44.26 40.27 37.41 38.62 38.57 44.52 40.57 37.72 39.60 39.55 Total 23.81 30.28 28.96 37.39 37.34 25.15 32.47 30.98 38.62 38.57 26.43 34.55 32.88 39.60 39.55 Sens‡ Capacity MBtuh† 39.58 36.07 33.53 33.78 33.73 39.99 36.51 33.97 34.93 34.89 40.25 36.83 34.30 35.86 35.81 Total Capacity MBtuh† 4.41 4.44 4.46 4.46 4.46 4.49 4.53 4.55 4.54 4.54 4.57 4.62 4.64 4.62 4.62 Total System KW** 4.23 4.19 4.17 4.17 4.17 4.30 4.26 4.24 4.25 4.25 4.37 4.34 4.31 4.33 4.33 Total System KW** 125 (51.7) 125 (51.7) 19.77 25.33 24.21 31.76 31.72 20.94 27.23 25.96 32.78 32.74 22.06 29.02 27.60 33.58 33.55 Sens‡ 40.51 36.84 34.22 35.08 35.03 40.81 37.17 34.56 36.15 36.11 40.96 37.43 34.82 36.98 36.94 Total 22.69 29.16 27.85 35.08 35.03 24.02 31.32 29.83 36.15 36.11 25.28 33.33 31.65 36.98 36.94 Sens‡ Capacity MBtuh† 36.71 33.47 31.10 31.76 31.72 37.02 33.83 31.47 32.78 32.74 37.22 34.11 31.77 33.58 33.55 Total Capacity MBtuh† 4.89 4.91 4.92 4.91 4.91 4.98 5.00 5.01 5.00 5.00 5.07 5.09 5.10 5.09 5.09 Total System KW** 4.70 4.66 4.64 4.64 4.64 4.77 4.74 4.71 4.72 4.72 4.85 4.81 4.78 4.80 4.80 Total System KW** 16 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 63 (17.2)†† 62 (16.7) 57 (13.9) EWB ° F (° C) See notes on pg. 17 2250 2000 1750 CFM EVAPORATOR AIR 1800 1600 1400 CFM EWB ° F (° C) EVAPORATOR AIR 75 (23.9) 29.08 35.60 34.57 42.09 46.53 30.51 37.89 36.71 45.22 48.50 31.86 40.07 38.76 49.72 50.13 Sens‡ 67.62 61.61 57.26 56.64 56.19 68.55 62.54 58.17 58.38 58.30 69.20 63.21 58.84 60.10 60.03 Total 33.62 41.91 40.25 50.02 56.19 35.38 44.78 42.92 58.38 58.30 37.05 47.52 45.45 60.10 60.03 Sens‡ Capacity MBtuh† 57.54 52.60 49.11 48.14 46.53 58.62 53.60 50.08 49.23 48.50 59.40 54.34 50.79 50.22 50.13 Total Capacity MBtuh† 75 (23.9) 3.61 3.60 3.60 3.59 3.59 3.71 3.70 3.69 3.69 3.69 3.81 3.80 3.79 3.79 3.79 Total System KW** 3.21 3.24 3.26 3.26 3.26 3.27 3.30 3.32 3.32 3.33 3.33 3.36 3.39 3.39 3.39 Total System KW** 85 (29.4) 28.10 34.61 33.58 41.09 44.81 29.51 36.88 35.70 44.16 46.64 30.84 39.04 37.73 48.15 48.15 Sens‡ 64.17 58.55 54.46 54.07 53.95 64.97 59.34 55.24 55.95 55.88 65.50 59.93 55.83 57.51 57.44 Total 32.46 40.77 39.14 53.77 53.95 34.21 43.61 41.77 55.95 55.88 35.85 46.32 44.27 57.51 57.44 Sens‡ Capacity MBtuh† 54.91 50.19 46.86 45.97 44.81 55.85 51.08 47.72 46.99 46.64 56.54 51.73 48.35 48.15 48.15 Total Capacity MBtuh† 85 (29.4) 116BNA060****A Outdoor Section With CNPV*6124A** Indoor Section 4.00 60.58 31.27 4.41 56.79 30.03 3.97 55.32 39.59 4.38 51.90 38.34 3.96 51.50 37.96 4.36 48.36 36.73 3.96 51.61 51.61 4.36 48.99 48.99 3.96 51.53 51.53 4.36 48.93 48.93 4.10 61.24 32.99 4.51 57.31 31.73 4.07 56.00 42.40 4.48 52.47 41.12 4.06 52.18 40.57 4.46 48.93 39.29 4.06 53.34 53.34 4.47 50.54 50.54 4.06 53.28 53.28 4.46 50.48 50.48 4.20 61.65 34.62 4.61 57.62 33.34 4.17 56.49 45.07 4.58 52.89 43.73 4.16 52.68 43.02 4.56 49.37 41.69 4.16 54.74 54.74 4.57 51.77 51.77 4.16 54.68 54.68 4.57 51.71 51.71 Total System KW** 4.86 4.83 4.80 4.81 4.81 4.96 4.93 4.90 4.92 4.92 5.06 5.03 5.01 5.02 5.02 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh† Capacity MBtuh† System System System Total Sens‡ Total Sens‡ KW** KW** KW** 116BNA049****A Outdoor Section With CAP**6024A* Indoor Section 3.66 52.22 27.11 4.12 49.43 26.10 4.59 3.67 47.73 33.62 4.10 45.16 32.59 4.55 3.67 44.56 32.57 4.08 42.14 31.53 4.53 3.66 43.75 40.07 4.08 41.45 38.99 4.52 3.66 43.02 43.02 4.07 41.13 41.13 4.52 3.73 53.04 28.50 4.19 50.14 27.47 4.66 3.74 48.50 35.86 4.17 45.83 34.82 4.63 3.74 45.31 34.68 4.16 42.81 33.63 4.61 3.74 44.76 44.49 4.16 42.69 42.69 4.61 3.74 44.72 44.72 4.16 42.69 42.69 4.61 3.80 53.64 29.82 4.26 50.65 28.78 4.74 3.81 49.07 38.01 4.25 46.33 36.96 4.71 3.81 45.87 36.70 4.23 43.30 35.63 4.69 3.81 46.11 46.11 4.24 43.96 43.96 4.69 3.81 46.11 46.11 4.24 43.96 43.96 4.69 DETAILED COOLING CAPACITIES# (CONT.) 116B 115 (46.1) 115 (46.1) 25.03 31.50 30.44 39.06 39.07 26.39 33.72 32.51 40.49 40.50 27.68 35.84 34.49 41.64 41.64 Sens‡ 52.77 48.28 45.00 46.15 46.09 53.16 48.74 45.49 47.51 47.45 53.39 49.12 45.89 48.57 48.52 Total 28.73 37.03 35.42 46.15 46.09 30.40 39.76 37.93 47.51 47.45 32.00 42.29 40.23 48.57 48.52 Sens‡ Capacity MBtuh† 46.46 42.41 39.56 39.06 39.07 47.06 42.99 40.14 40.49 40.50 47.47 43.41 40.56 41.64 41.64 Total Capacity MBtuh† 5.37 5.33 5.31 5.32 5.32 5.47 5.43 5.41 5.42 5.42 5.57 5.53 5.51 5.53 5.53 Total System KW** 5.09 5.06 5.03 5.02 5.02 5.17 5.13 5.11 5.11 5.11 5.25 5.21 5.19 5.19 5.19 Total System KW** 125 (51.7) 125 (51.7) 23.88 30.33 29.25 36.78 36.78 25.22 32.52 31.30 38.05 38.05 26.50 34.61 33.24 39.07 39.07 Sens‡ 48.49 44.39 41.41 43.04 42.99 48.76 44.80 41.84 44.19 44.14 48.89 45.19 42.31 45.09 45.04 Total 27.36 35.62 34.01 43.04 42.99 29.01 38.28 36.44 44.19 44.14 30.59 44.77 42.31 45.09 45.04 Sens‡ Capacity MBtuh† 43.18 39.40 36.72 36.78 36.78 43.67 39.88 37.20 38.05 38.05 43.99 40.23 37.56 39.07 39.07 Total Capacity MBtuh† 5.94 5.90 5.88 5.90 5.90 6.04 6.01 5.99 6.00 6.00 6.14 6.11 6.09 6.11 6.11 Total System KW** 5.66 5.62 5.60 5.60 5.60 5.74 5.70 5.68 5.68 5.68 5.81 5.78 5.76 5.77 5.77 Total System KW** 17 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 72 (22.2) 67 (19.4) 62 (16.7) 57 (13.9) 68.26 62.16 56.92 55.79 69.37 63.22 58.30 58.04 70.16 64.02 59.97 59.89 Total 35.40 43.65 51.79 55.79 37.22 46.57 55.64 58.04 38.93 49.36 59.97 59.89 Sens‡ Capacity MBtuh† 75 (23.9) 3.65 3.59 3.54 3.53 3.75 3.69 3.64 3.64 3.85 3.79 3.75 3.75 Total System KW** 65.62 59.80 54.89 54.23 66.58 60.75 56.40 56.32 67.25 61.43 58.12 58.04 Total 34.24 42.52 50.66 54.23 36.03 45.42 56.40 56.32 37.73 48.19 58.12 58.04 Sens‡ Capacity MBtuh† 85 (29.4) CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 95 (35) 105 (40.6) Total Total Total Capacity MBtuh† Capacity MBtuh† System System System Total Sens‡ Total Sens‡ KW** KW** KW** 116BNA061****A Outdoor Section With CNPV*6124A**+TDR Indoor Section 4.19 62.70 33.02 4.80 59.44 31.72 5.50 4.12 57.18 41.32 4.72 54.27 40.05 5.42 4.07 52.67 49.40 4.67 50.45 50.45 5.37 4.06 52.43 52.43 4.67 50.37 50.37 5.37 4.29 63.50 34.78 4.91 60.12 33.47 5.61 4.22 58.00 44.20 4.83 54.96 42.90 5.54 4.18 54.43 54.43 4.79 52.18 52.18 5.50 4.17 54.35 54.35 4.79 52.12 52.12 5.50 4.39 64.06 36.47 5.01 60.55 35.14 5.72 4.32 58.58 46.94 4.94 55.46 45.61 5.65 4.29 55.99 55.99 4.91 53.58 53.58 5.62 4.29 55.93 55.93 4.91 53.52 53.52 5.62 115 (46.1) 55.84 51.03 48.08 48.01 56.36 51.60 49.62 49.56 56.68 52.01 50.85 50.79 Total 30.35 38.69 48.08 48.01 32.08 41.51 49.62 49.56 33.73 44.17 50.85 50.79 Sens‡ Capacity MBtuh† 6.31 6.24 6.19 6.19 6.43 6.35 6.32 6.32 6.54 6.47 6.45 6.45 Total System KW** 116B { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C). # Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240--- 2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. ** System kw is total of indoor and outdoor unit kilowatts. {{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EWB — Entering Wet Bulb 2250 2000 1750 CFM EWB ° F (° C) EVAPORATOR AIR DETAILED COOLING CAPACITIES# (CONT.) 125 (51.7) 51.84 47.43 45.35 45.29 52.22 47.88 46.69 46.64 52.43 48.25 47.74 47.69 Total 28.89 37.23 45.35 45.29 30.60 40.00 46.69 46.64 32.24 42.59 47.74 47.69 Sens‡ Capacity MBtuh† 7.25 7.18 7.15 7.15 7.37 7.30 7.28 7.28 7.48 7.41 7.41 7.40 Total System KW** CONDENSER ONLY RATINGS SST ° F (° C) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 116B 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 55 (12.78) 65 (18.33) TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 15.70 66.60 0.75 17.50 67.80 0.75 19.40 69.00 0.74 21.50 70.40 0.74 23.60 71.60 0.73 25.90 73.00 0.73 14.90 76.20 0.87 16.60 77.30 0.87 18.40 78.50 0.87 20.30 79.70 0.86 22.40 80.90 0.86 24.50 82.10 0.86 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 20.30 66.10 1.00 22.60 67.20 0.99 24.90 68.40 0.98 27.40 69.60 0.97 30.10 70.80 0.96 33.00 72.10 0.95 19.40 75.80 1.15 21.40 76.80 1.14 23.70 77.90 1.14 26.00 79.00 1.14 28.60 80.10 1.13 31.30 81.30 1.13 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 24.90 68.10 1.27 27.50 69.40 1.28 30.30 70.70 1.29 33.30 72.00 1.29 36.50 73.50 1.29 39.90 75.00 1.29 23.50 77.50 1.43 26.00 78.70 1.44 28.60 79.90 1.44 31.50 81.20 1.44 34.50 82.50 1.44 37.80 84.00 1.44 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 116BNA018****B 14.10 13.20 12.30 11.30 85.80 95.30 104.80 114.30 0.99 1.12 1.26 1.41 15.70 14.70 13.70 12.60 86.80 96.30 105.70 115.10 0.99 1.12 1.26 1.42 17.40 16.30 15.20 14.00 87.90 97.30 106.60 115.90 0.99 1.12 1.26 1.42 19.20 18.00 16.70 15.50 89.00 98.30 107.60 116.90 0.99 1.13 1.27 1.43 21.10 19.70 18.40 17.00 90.10 99.40 108.60 117.80 1.00 1.13 1.28 1.44 23.10 21.60 20.10 18.60 91.30 100.50 109.70 118.80 1.00 1.14 1.29 1.45 116BNA024****A 18.30 17.20 16.10 14.80 85.30 94.90 104.40 114.00 1.30 1.47 1.65 1.85 20.30 19.10 17.80 16.50 86.30 95.80 105.30 114.70 1.30 1.47 1.65 1.86 22.40 21.00 19.60 18.20 87.30 96.70 106.10 115.50 1.30 1.47 1.66 1.86 24.60 23.10 21.60 20.10 88.30 97.70 107.00 116.30 1.30 1.48 1.66 1.87 27.00 25.40 23.70 22.00 89.40 98.70 107.90 117.20 1.30 1.48 1.67 1.88 29.50 27.70 25.90 24.10 90.50 99.70 108.90 118.10 1.31 1.49 1.68 1.89 116BNA030****A 22.20 20.80 19.40 17.90 87.00 96.40 105.80 115.10 1.60 1.78 1.99 2.23 24.50 23.10 21.50 19.90 88.10 97.40 106.70 116.00 1.61 1.79 2.00 2.24 27.10 25.50 23.80 22.00 89.20 98.50 107.70 117.00 1.61 1.80 2.01 2.25 29.80 28.00 26.20 24.30 90.40 99.60 108.80 118.00 1.61 1.80 2.01 2.26 32.60 30.70 28.80 26.70 91.70 100.80 110.00 119.20 1.61 1.80 2.02 2.26 35.70 33.60 31.50 29.30 93.00 102.10 111.20 120.30 1.61 1.80 2.02 2.27 See notes on page 20 18 115 (46.11) 125 (51.67) 10.20 123.70 1.60 11.50 124.40 1.60 12.80 125.20 1.60 14.10 126.10 1.61 15.60 127.00 1.62 17.10 128.00 1.63 9.20 133.10 1.81 10.30 133.80 1.81 11.50 134.50 1.81 12.80 135.30 1.82 14.10 136.20 1.82 15.50 137.10 1.84 13.60 123.40 2.09 15.10 124.10 2.09 16.70 124.80 2.09 18.40 125.60 2.10 20.20 126.40 2.11 22.10 127.30 2.12 12.20 132.80 2.36 13.60 133.50 2.36 15.10 134.10 2.36 16.70 134.90 2.37 18.40 135.60 2.37 20.20 136.40 2.39 16.20 124.40 2.50 18.10 125.30 2.51 20.10 126.20 2.52 22.30 127.20 2.53 24.50 128.20 2.54 26.90 129.30 2.54 14.40 133.60 2.81 16.20 134.40 2.82 18.10 135.30 2.83 20.10 136.30 2.85 22.20 137.20 2.86 24.40 138.20 2.86 SST ° F (° C) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 55 (12.78) 65 (18.33) TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 31.50 68.90 1.50 34.80 70.10 1.50 38.30 71.40 1.51 42.10 72.80 1.52 46.20 74.40 1.53 50.50 76.00 1.55 29.90 78.20 1.73 33.00 79.30 1.73 36.40 80.60 1.74 40.00 81.90 1.75 43.90 83.30 1.77 47.90 84.90 1.79 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 37.90 69.80 1.83 41.90 71.20 1.84 46.10 72.70 1.85 50.70 74.20 1.86 55.50 75.80 1.87 60.70 77.40 1.89 36.20 79.20 2.03 40.00 80.60 2.04 44.00 81.90 2.05 48.30 83.30 2.07 52.90 84.80 2.09 57.70 86.40 2.11 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 42.80 67.80 2.00 47.40 69.00 1.93 52.30 70.40 1.82 57.80 71.80 1.68 63.70 73.20 1.49 70.10 74.70 1.25 40.60 77.20 2.29 44.80 78.30 2.25 49.50 79.60 2.18 54.60 80.80 2.07 60.10 82.20 1.93 66.00 83.70 1.74 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 116BNA036****A 28.30 26.60 24.80 22.90 87.50 96.80 106.20 115.50 1.96 2.21 2.50 2.82 31.20 29.40 27.40 25.40 88.60 97.90 107.20 116.50 1.97 2.22 2.51 2.83 34.40 32.40 30.30 28.10 89.80 99.00 108.20 117.40 1.98 2.24 2.52 2.85 37.80 35.60 33.30 30.90 91.00 100.20 109.40 118.50 1.99 2.25 2.54 2.86 41.50 39.00 36.50 33.90 92.40 101.50 110.50 119.60 2.01 2.27 2.56 2.88 45.30 42.70 39.90 37.10 93.80 102.80 111.80 120.80 2.04 2.30 2.58 2.91 116BNA042****A 34.30 32.30 30.10 27.90 88.70 98.10 107.40 116.70 2.26 2.54 2.86 3.22 37.90 35.70 33.30 30.80 89.90 99.20 108.40 117.70 2.28 2.56 2.88 3.24 41.70 39.20 36.70 34.00 91.20 100.40 109.60 118.70 2.30 2.58 2.90 3.26 45.80 43.10 40.20 37.30 92.50 101.60 110.80 119.80 2.32 2.60 2.92 3.29 50.10 47.10 44.00 40.80 93.90 103.00 112.00 121.00 2.34 2.63 2.95 3.32 54.60 51.30 47.90 44.40 95.40 104.40 113.40 122.30 2.36 2.66 2.99 3.36 116BNA048****B 38.30 36.00 33.60 31.10 86.60 96.00 105.40 114.70 2.58 2.87 3.17 3.51 42.30 39.70 37.10 34.40 87.70 97.00 106.30 115.60 2.56 2.87 3.19 3.53 46.60 43.80 40.90 37.90 88.80 98.00 107.20 116.50 2.52 2.85 3.19 3.55 51.40 48.20 45.00 41.70 90.00 99.10 108.30 117.40 2.45 2.81 3.17 3.55 56.50 52.90 49.40 45.70 91.30 100.30 109.40 118.50 2.34 2.74 3.13 3.53 62.00 58.00 54.10 50.00 92.60 101.60 110.60 119.60 2.20 2.63 3.06 3.49 See notes on page 20 19 115 (46.11) 125 (51.67) 21.00 124.90 3.21 23.30 125.80 3.21 25.80 126.70 3.22 28.40 127.70 3.24 31.20 128.70 3.25 34.20 129.80 3.28 18.90 134.20 3.66 21.10 135.00 3.66 23.40 135.90 3.66 25.80 136.80 3.67 28.40 137.70 3.68 31.10 138.70 3.70 25.50 125.90 3.63 28.30 126.80 3.65 31.20 127.80 3.67 34.30 128.90 3.70 37.50 130.00 3.73 40.80 131.20 3.77 23.00 135.10 4.09 25.60 136.00 4.10 28.30 136.90 4.13 31.10 137.90 4.15 34.10 138.90 4.19 37.10 140.00 4.22 28.50 124.00 3.90 31.60 124.80 3.92 34.90 125.70 3.94 38.30 126.60 3.95 42.00 127.50 3.95 45.90 128.50 3.94 25.80 133.30 4.35 28.60 134.10 4.36 31.60 134.80 4.38 34.80 135.70 4.40 38.10 136.50 4.41 41.60 137.40 4.41 116B CONDENSER ONLY RATINGS CONTINUED CONDENSER ONLY RATINGS CONTINUED SST ° F (° C) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 116B 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 30 ( --- 1.11) 35 (1.67) 40 (4.44) 45 (7.22) 50 (10.0) 55 (12.78) 55 (12.78) 65 (18.33) TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 45.00 70.30 2.04 49.80 71.70 1.99 54.90 73.20 1.93 60.40 74.80 1.86 66.20 76.40 1.78 72.40 78.20 1.68 42.40 79.50 2.41 46.80 80.90 2.39 51.50 82.40 2.36 56.60 83.90 2.33 62.00 85.50 2.28 67.70 87.10 2.23 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 49.90 70.90 2.31 55.30 72.50 2.31 61.00 74.10 2.31 67.20 75.80 2.31 73.70 77.60 2.31 80.80 79.50 2.31 47.50 80.40 2.60 52.60 81.80 2.61 58.00 83.40 2.63 63.80 84.90 2.64 70.00 86.60 2.65 76.60 88.40 2.66 TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW TCG SDT KW 47.40 70.70 1.95 52.30 72.20 1.98 57.60 73.90 2.01 63.20 75.60 2.05 69.20 77.40 2.09 75.60 79.30 2.14 46.30 80.00 2.35 51.10 81.40 2.38 56.20 82.90 2.41 61.70 84.50 2.45 67.50 86.20 2.50 73.70 88.00 2.56 CONDENSER ENTERING AIR TEMPERATURES ° F (° C) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 116BNA049****A 39.90 37.40 34.90 32.30 88.90 98.20 107.60 116.90 2.75 3.08 3.44 3.84 44.00 41.20 38.50 35.60 90.10 99.40 108.70 118.00 2.75 3.10 3.47 3.87 48.40 45.30 42.20 39.10 91.50 100.70 109.90 119.00 2.75 3.12 3.50 3.91 53.00 49.60 46.20 42.80 92.90 102.00 111.10 120.20 2.75 3.14 3.53 3.95 58.00 54.20 50.50 46.70 94.50 103.40 112.40 121.40 2.73 3.15 3.56 3.99 63.20 59.10 55.00 50.90 96.10 104.90 113.80 122.60 2.71 3.16 3.59 4.02 116BNA060****A 45.10 42.40 39.60 36.70 89.80 99.20 108.50 117.80 2.90 3.24 3.61 4.05 49.80 46.90 43.90 40.70 91.20 100.50 109.70 118.90 2.93 3.27 3.65 4.08 54.90 51.70 48.40 45.00 92.60 101.80 111.00 120.10 2.95 3.29 3.68 4.12 60.30 56.90 53.30 49.60 94.10 103.20 112.30 121.40 2.97 3.32 3.71 4.15 66.20 62.40 58.50 54.50 95.70 104.70 113.70 122.70 2.99 3.35 3.75 4.19 72.40 68.30 64.00 59.80 97.30 106.20 115.20 124.00 3.02 3.39 3.79 4.24 116BNA061****A 45.00 43.40 41.50 39.30 89.20 98.50 107.70 116.90 2.79 3.30 3.90 4.61 49.60 47.90 45.90 43.40 90.60 99.70 108.90 118.00 2.82 3.34 3.94 4.65 54.60 52.70 50.40 47.80 92.00 101.00 110.10 119.10 2.86 3.38 3.99 4.70 59.90 57.80 55.30 52.40 93.50 102.50 111.40 120.40 2.91 3.43 4.04 4.75 65.50 63.20 60.40 57.20 95.10 104.00 112.80 121.70 2.96 3.49 4.10 4.82 71.40 68.80 65.70 62.20 96.80 105.60 114.30 123.00 3.03 3.56 4.17 4.89 * AHRI listing applies only to systems shown in Combination Ratings table. KW --- Outdoor Unit Kilowatts Only. SDT --- Saturated Temperature Leaving Compressor (° F) SST --- Saturated Temperature Entering Compressor (° F/° C) TCG --- Gross Cooling Capacity (1000 Btuh) 20 115 (46.11) 125 (51.67) 29.50 126.20 4.32 32.60 127.20 4.34 35.80 128.20 4.38 39.30 129.20 4.41 42.90 130.30 4.45 46.70 131.40 4.49 26.40 135.40 4.89 29.30 136.30 4.90 32.30 137.20 4.92 35.50 138.10 4.94 38.70 139.10 4.98 42.10 140.10 5.01 33.50 127.00 4.56 37.30 128.10 4.59 41.40 129.20 4.63 45.70 130.40 4.66 50.40 131.60 4.70 55.30 132.90 4.74 30.20 136.30 5.17 33.80 137.30 5.19 37.60 138.30 5.22 41.70 139.40 5.25 46.10 140.50 5.28 50.70 141.60 5.32 36.80 126.00 5.45 40.70 127.00 5.49 44.80 128.10 5.54 49.00 129.20 5.59 53.50 130.40 5.65 58.20 131.70 5.72 33.80 135.10 6.46 37.40 136.00 6.49 41.20 137.00 6.53 45.20 138.10 6.58 49.40 139.10 6.64 53.60 140.30 6.70 System Description Outdoor--mounted, air--cooled, split--system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c--UL--us approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500--hr salt spray test. — Air--cooled condenser coils will be leak tested at 150 psig and pressure tested at 450 psig. — Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment Factory assembled, single piece, air--cooled air conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A), and special features required prior to field start--up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER 116B 1--1/2 TO 5 NOMINAL TONS Fans — Condenser fan will be direct--drive propeller type, discharging air upward. — Condenser fan motors will be totally enclosed, 1--phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid--line shutoff valve with sweat connections, vapor--line shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, and compressor oil. — Unit will be equipped with filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at _____ _F/_C. — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. 21 116B GUIDE SPECIFICATIONS GENERAL SYSTEM DESIGN SUMMARY 1. 2. 3. 4. 5. 6. 7. 116B 8. 9. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc. Minimum outdoor operating air temperature for cooling mode without low--ambient operation accessory is 55_F (12.8_C). Maximum outdoor operating air temperature is 125_F (51.7_C). For reliable operation, unit should be level in all horizontal planes. For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential Piping and Longline Guideline and Service Manual available from equipment distributor. If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4 mm). Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided. Do not apply capillary tube indoor coils to these units. Factory--supplied filter drier must be installed. Copyright 2012 Bryant Heating & Cooling Systems. S 7310 W. Morris St. S Indianapolis, IN 46231 Edition Date: 09/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 22 Catalog No: PDS116B---04 Replaces: PDS116B--- 03
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Format : application/pdf Creator : bact04l Title : PDS116B-04 Create Date : 2012:09:25 14:25:17-04:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2012:10:01 11:04:10-04:00 Metadata Date : 2012:10:01 11:04:10-04:00 Producer : Acrobat Distiller 8.3.1 (Windows) Document ID : uuid:0caae800-896d-4ba0-a8ec-7128489db8ac Instance ID : uuid:1e7f7467-d698-4ad7-8164-8674d86aa153 Page Count : 22 Author : bact04lEXIF Metadata provided by EXIF.tools