Bryant Air Conditioner 116B Users Manual PDS116B 04

Bryant Air Conditioner 116B PDS116B-04

116B to the manual 939eda02-f816-4cbd-9659-06afcae64de4

2015-02-02

: Bryant Bryant-Air-Conditioner-116B-Users-Manual-411802 bryant-air-conditioner-116b-users-manual-411802 bryant pdf

Open the PDF directly: View PDF PDF.
Page Count: 22

DownloadBryant Bryant-Air-Conditioner-116B-Users-Manual- PDS116B-04  Bryant-air-conditioner-116b-users-manual
Open PDF In BrowserView PDF
116B
Legacyt Line 16 Air Conditioner
with Puronr Refrigerant
1--1/2 to 5 Nominal Tons

Product Data
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S 14 -- 16.5 SEER/11.0-- 13.5 EER
S Microtube Technologyt refrigeration system
S Indoor air quality accessories available
Sound
S Sound level as low as 76 dBA
S Sound level as low as 74 dBA with accessory sound
blanket

Comfort
S System supports Edger Thermidistatt or standard
thermostat controls

Reliability
S Puronr refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.

the environmentally sound refrigerant

Bryant’s Air Conditioners with Puronr refrigerant provide a
collection of features unmatched by any other family of
equipment. The 116B has been designed utilizing Bryant’s Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s ozone
layer.
This product has been designed and manufactured to meet
Energy Starr criteria for energy efficiency when matched with
appropriate coil components. Refer to the combination ratings in
the Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.

S Scroll compressor
S Internal pressure relief valve
S Internal thermal overload
S Filter drier
S Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:

S Solid, durable sheet metal construction
S Dense wire coil guard standard
S Baked--on, complete outer coverage, powder paint
Applications
S Long--line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)

S

Low ambient
accessory kit

(down

to

--20_F/--28.9_C)) with

MODEL NUMBER NOMENCLATURE
1
N

2
N

3
N

4
A

5
A/N

6
N

7
N

8
N

9
N

10
A/N

11
A/N

12
N

14
A

1

1

6

B

N

A

0

3

6

0

0

0

0

Product
Family

Tier

SEER

Major
Series

Voltage

Grille
Variations

Open

Open

Open

Series

B=Puron

N=
208--- 230--- 1
or
208/230--- 1

A = Dense

0=Not
Defined

0=Not
Defined

1=AC

1=
Legacy
RNC

6=16 SEER

Cooling Capacity

0=Not
Defined

ISO 9001:2000

the environmentally sound refrigerant

REGISTERED

116B

Use of the AHRI Certified
TM Mark indicates a
manufacturer’s
participation in the
program For verification
of certification for individual
products, go to
www.ahridirectory.org.

This product has been designed and manufactured to
meet Energy Star® criteria for energy efficiency when
matched with appropriate coil components. However,
proper refrigerant charge and proper air flow are critical
to achieve rated capacity and efficiency. Installation of
this product should follow all manufacturing refrigerant
charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy
efficiency and shorten equipment life.

STANDARD FEATURES
Feature

018

024

030

036

042

048 / 049

Puron Refrigerant

X

X

X

X

X

X

060 / 061
X

Maximum SEER *

16.0

16.0

16.5

16.5

16.0

16.0

16.0

Scroll Compressor

X

X

X

X

X

X

X

Field Installed Filter Drier

X

X

X

X

X

X

X

Front Seating Service Valves

X

X

X

X

X

X

X

Internal Pressure Relief Valve

X

X

X

X

X

X

X

Internal Thermal Overload

X

X

X

X

X

X

X

Long Line capability

X

X

X

X

X

X

X

Low Ambient capability with Kit

X

X

X

X

X

X

X

Dense Grille

X

X

X

X

X

X

X

049--- A
231
(104.8)
269
(222.0)

060--- A
272
(123.4)
310
(140.6)

061--- A
272
(123.4)
310
(140.6)

9.00
(4.08)

14.50
(6.58)

14.50
(6.58)

* With approved combinations
X = Standard

PHYSICAL DATA
UNIT SIZE --- VOLTAGE, SERIES
Operating Weight lb (kg)
Shipping Weight lb (kg)

018--- B
125
(56.7)
154
(69.9)

024--- A
147
(66.5)
183
(82.8)

030--- A
153
(69.3)
188
(85.2)

4.60
(2.09)

6.00
(2.72)

6.81
(3.09)

Compressor Type
REFRIGERANT
Control
Charge lb (kg)

036--- A
165
(74.8)
204
(92.5)

042--- A
048--- B
213
264
(96.4)
(119.7)
254
317
(115.2)
(143.8)
Scroll
Puron® (R---410A)
TXV (Puron® Hard Shutoff)
7.00
8.62
13.0
(3.18)
(3.91)
(5.90)
Propeller Type, Direct Drive
Vertical
3223
3810
4046
1/12
1/5
1/4
800
800
800

COND FAN
Air Discharge
Vertical
Air Qty (CFM)
1881
2614
2614
4046
4046
4046
Motor HP
1/12
1/10
1/10
1/4
1/4
1/4
Motor RPM
1100
1100
1100
800
800
800
COND COIL
Face Area (Sq ft)
11.50
15.10
17.20
17.60
25.15
25.15
25.15
30.15
30.15
Fins per In.
25
25
25
25
25
20
20
20
20
Rows
1
1
1
1
1
2
1
2
2
Circuits
3
4
4
4
6
7
7
8
8
VALVE CONNECT. (In. ID)
Vapor
3/4
3/4
3/4
7/8
7/8
7/8
7/8
7/8
7/8
Liquid
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
REFRIGERANT TUBES (In. OD)
Rated Vapor*
3/4
7/8
1 ---1/8
Max Liquid Line {
3/8
* Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset.
Note: See unit Installation Instruction for proper installation.
{ See Liquid Line Sizing For Cooling Only Systems with Puron Refrigerant tables.

2

REFRIGERANT PIPING LENGTH LIMITATIONS
Liquid Line Sizing and Maximum Total Equivalent Lengths{ for Cooling Only Systems with Puronr Refrigerant:
The maximum allowable length of a residential split system depends on the liquid line diameter and vertical separation between indoor and
outdoor units.
See Table below for liquid line sizing and maximum lengths :
Maximum Total Equivalent Length
Outdoor Unit BELOW Indoor Unit

18000
AC with
Puron

3/8

24000
AC with
Puron

3/8

30000
AC with
Puron

3/8

Liquid
Line
Diam.
w/ TXV
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8

AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit BELOW Indoor
Vertical Separation ft (m)
0--- 5
(0--- 1.5)

6--- 10
(1.8--- 3.0)

11--- 20
(3.4--- 6.1)

21--- 30
(6.4--- 9.1)

31--- 40
(9.4--- 12.2)

41--- 50
(12.5--- 15.2)

51--- 60
(15.5--- 18.3)

61--- 70
(18.6--- 21.3)

71--- 80
(21.6--- 24.4)

150
250*
250*
75
250*
250*
30
175
250*

150
250*
250*
75
250*
250*
--- --225*
250*

125
250*
250*
75
250*
250*
--- --200
250*

100
250*
250*
50
250*
250*
--- --175
250*

100
250*
250*
50
250*
250*
--- --125
250*

75
250*
250*
--- --225*
250*
--- --100
250*

--- --250*
250*
--- --175
250*
--- --75
250*

--- --225*
250*
--- --125
250*
--- ----- --250*

--- --150
250*
--- --100
250*
--- ----- --250*

36000
5/16
175
150
150
100
AC with
3/8
3//8
250*
250*
250*
250*
Puron
42000
5/16
125
100
100
75
AC with
3/8
3/8
250*
250*
250*
250*
Puron
48000
AC with
3/8
3/8
250*
250*
250*
250*
Puron
49000
AC with
3/8
3/8
250*
250*
250*
250*
Puron
60000
AC with
3/8
3/8
250*
250*
250*
225*
Puron
61000
AC with
3/8
3/8
250*
250*
250*
225*
Puron
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line
--- --- = outside acceptable range

100

100

75

--- ---

--- ---

250*

250*

250*

250*

250*

75

50

--- ---

--- ---

--- ---

250*

250*

250*

250*

150

250*

250*

230

160

--- ---

250*

250*

230

160

--- ---

190

150

110

--- ---

--- ---

190

150

110

--- ---

--- ---

Guideline for details.

Maximum Total Equivalent Length
Outdoor Unit ABOVE Indoor Unit
Size

Liquid Line
Connection

18000
AC with
Puron

3/8

24000
AC with
Puron

3/8

30000
AC with
Puron

3/8

Liquid
Line
Diam.
w/ TXV
1/4
5/16
3/8
1/4
5/16
3/8
1/4
5/16
3/8

AC with Puron Refrigerant Maximum Total Equivalent Length{: Outdoor unit ABOVE Indoor
Vertical Separation ft (m)
25
(7.6)

26--- 50
(7.9--- 15.2)

51--- 75
(15.5--- 22.9)

76--- 100
(23.2--- 30.5)

101--- 125
(30.8--- 38.1)

126--- 150
(38.4--- 45.7)

151--- 175
(46.0--- 53.3)

176--- 200
(53.6--- 61.0)

175
250*
250*
100
250*
250*
30
250*
250*

250*
250*
250*
125
250*
250*
--- --250*
250*

250*
250*
250*
175
250*
250*
--- --250*
250*

250*
250*
250*
200
250*
250*
--- --250*
250*

250*
250*
250*
225*
250*
250*
--- --250*
250*

250*
250*
250*
250*
250*
250*
--- --250*
250*

250*
250*
250*
250*
250*
250*
--- --250*
250*

250*
250*
250*
250*
250*
250*
--- --250*
250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

250*

36000
5/16
225*
250*
250*
250*
250*
3/8
AC with
3/8
250*
250*
250*
250*
250*
Puron
42000
5/16
175
200
250*
250*
250*
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
48000
3/8
3/8
250*
250*
250*
250*
250*
AC with
Puron
49000
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
60000
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
61000
AC with
3/8
3/8
250*
250*
250*
250*
250*
Puron
* Maximum actual length not to exceed 200 ft (61 m)
{ Total equivalent length accounts for losses due to elbows or fitting. See the Long Line Guideline for details.
--- --- = outside acceptable range

3

116B

Size

Liquid Line
Connection

REFRIGERANT CHARGE ADJUSTMENTS
Liquid Line Size

Puron Charge oz/ft

3/8

0.60
(Factory charge for lineset = 9 oz)

5/16

0.40

1/4

0.27

116B

Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line. The factory charge for 3/8” lineset 9 oz. When using other length or diameter
liquid lines, charge adjustments are required per the chart above.
Charging Formula:
[(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment
Example 1: System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required?
Formula:
(.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz.
Net result is to remove 4.95 oz of refrigerant from the system
Example 2: System has 45 ft of existing 5/16” liquid line. What is the charge adjustment?
Formula:
(.40 oz/ft. x 45ft) – (9 oz.) = 9 oz.
Net result is to add 9 oz of refrigerant to the system

LONG LINE APPLICATIONS
An application is considered Long Line, when the refrigerant level in the system requires the use of accessories to maintain acceptable
refrigerant management for systems reliability. See Accessory Usage Guideline table for required accessories. Defining a system as long line
depends on the liquid line diameter, actual length of the tubing, and vertical separation between the indoor and outdoor units.
For Air Conditioner systems, the chart below shows when an application is considered Long Line.
AC WITH PURONr REFRIGERANT LONG LINE DESCRIPTION ft (m)
Beyond these lengths, long line accessories are required
Liquid Line Size
1/4

Units On Same Level
No accessories needed within allowed
lengths

Outdoor Below Indoor
No accessories needed within allowed
lengths

Outdoor Above Indoor
175 (53.3)

5/16

120 (36.6)

50 (15.2)

120 (36.6)

3/8

80 (24.4)

35 (10.7)

80 (24.4)

Note: See Long Line Guideline for details

VAPOR LINE SIZING AND COOLING CAPACITY LOSS
Acceptable vapor line diameters provide adequate oil return to the compressor while avoiding excessive capacity loss. The suction line
diameters shown in the chart below are acceptable for AC systems with Puron refrigerant:
Unit
Nominal
Size (Btuh)
18000
1 Stage
AC with
Puron
24000
1 Stage
AC with
Puron
30000
1 Stage
AC with
Puron
36000
1 Stage
AC with
Puron
42000
1 Stage
AC with
Puron
48000,
49000
1 Stage
AC with
Puron
60000,
61000
1 Stage
AC with
Puron

Maximum
Liquid Line
Diameters
(In. OD)
3/8

3/8

3/8

3/8

3/8

3/8

3/8

Vapor Line
Diameters
(In. OD)

26--- 50

51--- 80

81--- 100

(7.9--- 15.2)

(15.5--- 24.4)

(24.7--- 30.5)

1/2

1

2

5/8

0

1

3/4

0

5/8

Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
101--- 125
126--- 150
151--- 175

176--- 200

201--- 225

226--- 250

(30.8--- 38.1)

(38.4--- 45.7)

(46.0--- 53.3)

(53.6--- 61.0)

(61.3--- 68.6)

(68.9--- 76.2)

3

5

6

7

8

9

11

1

1

2

2

2

3

3

0

0

0

1

1

1

1

1

0

1

2

2

3

3

4

5

5

3/4

0

0

1

1

1

1

1

2

2

7/8

0

0

0

0

0

1

1

1

1

5/8

1

2

3

3

4

5

6

7

8

3/4

0

0

1

1

1

2

2

2

3

7/8

0

0

0

0

1

1

1

1

1

5/8

1

2

4

5

6

8

9

10

12

3/4

0

1

1

2

2

3

3

4

4

7/8

0

0

0

1

1

1

1

2

2

3/4

0

1

2

2

3

4

4

5

6

7/8

0

0

1

1

1

2

2

2

3

1 1/8

0

0

0

0

0

0

0

0

0

3/4

0

1

2

3

4

5

5

6

7
3

7/8

0

0

1

1

2

2

2

3

1 1/8

0

0

0

0

0

0

0

1

1

3/4

1

2

4

5

6

7

9

10

11

7/8

0

1

2

2

3

4

4

5

5

1 1/8

0

0

0

1

1

1

1

1

1

Applications in this area may be long line and may have height restrictions. See the Residential Piping and Long Line Guideline.

4

ACCESSORY THERMOSTATS
PART NUMBER

PROGRAM

GAS

ELECTRIC

HEAT

COOL

T2 ---PAC01

5 ---2 Day

√

√

1

1

T2 ---NAC01

NP

√

√

1

1

T2SNAC01

NP

√

1

1

√

THERMOSTAT ACCESSORIES
PART NUMBER

BRIEF DESCRIPTION

THERMOSTATS USED WITH

TSTATXXCNV10

Thermostat Conversion Kit (4 to 5 wire) --- 10
pack

All Bryantr branded thermostats

TX ---LBP01

Large Decorative Backplate

T6 ---Pxx, T6 ---Nxx, and T2 ---Pxx

TX ---MBP01

Medium Decorative Backplate

T2 ---Nxx and T1 ---Pxx

ACCESSORIES
DESCRIPTION

Unit Sizes --- Series
018--- B

024--- A

030--- A

036--- A

042--- A

048--- B

049--- A

060--- A

061--- A

KAAFT0101AAA

FREEZE THERMOSTAT

X

X

X

X

X

X

X

X

X

KAATD0101TDR

TIME DELAY RELAY

X

X

X

X

X

X

X

X

X

KSALA0301410

LOW AMBIENT PSW

X

X

X

X

X

X

X

X

X

KSALA0601AAA{

MOTORMASTER 230V

X

X

X

X

X

X

X

X

X

HC32GE234

MOTOR FAN BALL BEARING

X

HC34GE240

MOTOR FAN BALL BEARING

X

X

HC32GE229

MOTOR FAN BALL BEARING

HC38GE228

MOTOR FAN BALL BEARING

HC40GE228

MOTOR FAN BALL BEARING

X

X

X

X

KSAHS1701AAA

HARD START (CAP / RELAY)

X

X

X

X

X

X

X

X

X

KSACY0101AAA

CYCLE PROTECTOR

X

X

X

X

X

X

X

X

X

KSASF0101AAA

SUPPORT FEET

X

X

X

X

X

X

X

X

X

KAACS0201PTC

START ASSIST PTC

X

X

X

X

X

X

X

X

X

KAALS0201LLS

LIQUID LINE SOLENOID

X

X

X

X

X

X

X

X

X

KAAWS0101AAA

WINTER START

X

X

X

X

X

X

X

X

X

KAACH1701AAA

CRANKCASE HTR

X

X

X

X

KAACH1601AAA

CRANKCASE HTR

X

S

S

S

S

KSATX0201PUR

TXV PURON HSO

X

X

X

KSATX0301PUR

TXV PURON HSO

KSATX0401PUR

TXV PURON HSO

KSATX0501PUR

TXV PURON HSO

X

X

KSASH0601COP

SOUND HOOD

KSASH2101COP

SOUND HOOD

KAALP0401PUR
KAAHI0501PUR

X
X

X
X

X
X

X

X

X

X

X
X

X

X

X

LOW PRESSURE SWITCH

X

X

X

X

X

X

X

X

X

HIGH PRESSURE SWITCH

X

X

X

X

X

X

X

X

X

{ Required accessories include ball bearing fan motor, compressor start assist (CAP / Relay), crankcase heater, evaporator freeze stat, hard shut---off TXV.
X = Accessory / S --- Standard

5

116B

KIT NUMBER

ACCESSORY USAGE GUIDELINE
ACCESSORY
Ball Bearing Fan Motor
Compressor Start Assist Capacitor and Relay
Crankcase Heater
Evaporator Freeze Thermostat
Hard Shut---Off TXV
Liquid Line Solenoid Valve
Motor Master® Control or
Low---ambient Pressure Switch
Support Feet
Winter Start Control

Yes{
Yes
Yes
Yes
Yes
No

REQUIRED FOR LONG
LINE
APPLICATIONS*
(Over 80 ft./24.38 m)
No
Yes
Yes
No
Yes
No

REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles/3.22 km)
No
No
No
No
Yes
No

Yes

No

No

Recommended
Yes

No
No

Recommended
No

REQUIRED FOR LOW---AMBIENT COOLING APPLICATIONS
(Below 55°F/12.8_C)

116B

* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline
Application Guideline.
{ Required for Low---Ambient Controller (full modulation feature) MotorMasterr Control.

Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor
motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the
following applications:
Long line
Low ambient cooling
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the
following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles.
Improves compressor lubrication on restart and minimizes the
chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.

5. Cycle Protector
The cycle protector is designed to prevent compressor short
cycling. This control provides an approximate 5--minute delay
after power to the compressor has been interrupted for any
reason, including power outage, protector control trip, thermostat
jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in
order to maintain head pressure within normal operating limits
(approximately 100 psig to 225 psig). The control will maintain
working head pressure at low--ambient temperatures down to 0_F
(--18_C) when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is
used at outdoor temperatures below 55_F (12.8_C).
8. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C),
it maintains condensing temperature at 100_F ±10_F (37.8_C ±
5.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.
9. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary
heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this
publication.

6

Accessory Description and Usage (Listed Alphabetically) (Continued)
13. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
NOTE: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
For improved efficiency ratings for certain
combinations of indoor and outdoor units. Refer to
AHRI Unitary Directory.
14. Winter Start Control
This control is designed to alleviate nuisance opening of the
low--pressure switch by bypassing it for the first 3 minutes of
operation.

116B

10. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces
the sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft (4.57 m) to
quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less
than 10 ft (3.05 m) apart.
11. Support Feet
Four stick--on plastic feet that raise the unit 4 in. (101.6 mm)
above the mounting pad. This allows sand, dirt, and other debris
to be flushed from the unit base, minimizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
12. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube.
Hard shut off types are available.
NOTE: When using a hard shut off TXV with single phase
reciprocating compressors, a Compressor Start Assist Capacitor
and Relay is required.
Usage Guideline:
Required to achieve AHRI ratings in certain equipment
combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner
long line applications.
Required for use on all zoning systems.

7

ELECTRICAL DATA
OPER VOLTS*
UNIT SIZE

MAX

MIN

LRA

MCA

MIN WIRE
SIZE{
60° C

MIN WIRE
SIZE{
75° C

MAX
LENGTH
ft. (m)}
60° C

FAN

RLA FLA

MAX
LENGTH
ft. (m)}
75° C

MAX FUSE**
or CKT BRK
AMPS

018--- B

48.0

9.0

0.50

11.8

14

14

67 (20.4)

64 (19.5)

20

024--- A

58.3

13.5 0.75

17.7

14

14

46 (14.0)

43 (13..1)

25

030--- A

64.0

12.8 0.75

16.8

14

14

44 (13.4)

41 (12.5)

25

036--- A

77.0

14.1 0.50

18.1

12

12

57 (17.4)

54 (16.5)

30

112.0

17.9 1.20

23.6

10

10

85 (25.9)

81 (24.7)

40

048--- B

109.0

19.9 1.20

26.1

10

10

70 (21.3)

67 (20.4)

40

049--- A

117.0

21.8 1.20

26.1

10

10

70 (21.3)

67 (20.4)

40

060--- A

135.0

21.4 1.20

28.0

8

10

91 (27.7)

56 (17.1)

40

042--- A

116B

COMPR

V/PH

208/230/1 ---60

253

197

061--- A
134.0
25.0 1.20 32.5
8
10
94 (28.7)
58 (17.7)
50
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30_C, consult table 310 ---16 of the NEC (NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade
name ROMEX, shall be that of 60_C conditions, per the NEC (NFPA 70) Article 334 ---80. If other than uncoated (no ---plated), 60 or 75_C insulation, copper
wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (NFPA 70).
}
Length shown is as measured one way along wire path between unit and service panel for voltage drop not to exceed 2%.
** Time ---Delay fuse.
FLA --- Full Load Amps
LRA --- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA --- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
Complies with 2007 requirements of ASHRAE Standards 90.1

A--WEIGHTED SOUND POWER LEVEL (dBA)
Unit Size --Voltage, Series

Standard
Rating (dBA)

0018--- B
0024--- A
0030--- A
0036--- A
0042--- A
0048--- B
0049--- A
0060--- A
0061--- A

76
76
76
76
78
78
78
78
78

125
52.5
57.5
55.0
50.5
52.5
57.5
51.5
55.0
56.5

TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
250
500
1000
2000
4000
59.0
65.5
70.5
64.5
59.0
64.0
69.0
71.0
69.0
64.5
63.5
68.0
69.5
67.0
63.5
59.5
64.5
70.5
62.0
59.5
62.0
66.0
73.5
68.0
62.0
61.5
66.0
70.5
65.5
59.5
62.0
67.5
73.5
69.0
64.5
62.5
67.5
70.5
65.0
61.0
63.0
65.5
69.0
67.0
61.5

8000
54.5
60.0
58.5
54.5
55.5
53.5
62.0
53.5
56.0

NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).

A--WEIGHTED SOUND POWER LEVEL (dBA) WITH SOUND SHIELD
Unit Size --Voltage, Series

Standard
Rating (dBA)

0018--- B
0024--- A
0030--- A
0036--- A
0042--- A
0048--- B
0049--- A
0060--- A
0061--- A

74
75
75
74
76
76
76
75
75

125
55.5
58.0
55.5
51.5
53.0
58.5
53.0
56.5
57.0

TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
250
500
1000
2000
4000
59.0
65.0
68.5
63.5
58.0
64.0
69.0
70.5
68.5
64.5
63.0
68.0
69.0
67.0
63.0
58.5
62.0
65.0
61.0
58.0
62.0
65.5
72.0
65.0
61.0
61.5
66.0
69.0
64.0
58.5
61.5
67.5
72.0
68.0
61.5
62.5
66.5
68.0
63.0
59.5
63.0
65.5
67.0
65.5
59.0

NOTE: Tested in accordance with AHRI Standard 270 ---08 (not listed in AHRI).

CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- VOLTAGE, SERIES
018--- B
024--- A
030--- A
036--- A
042--- A
048--- B
049--- A
060--- A
061--- A

REQUIRED SUBCOOLING _F (_C)
10 (5.6)
10 (5.6)
10 (5.6)
10 (5.6)
9 (5.0)
10 (5.6)
8 (4.4)
9 (5.0)
9 (5.0)

8

8000
52.0
59.5
58.5
52.0
54.0
51.0
59.0
51.5
52.5

9

A

A

A

A

A

A

B

A

B

A

116BNA024

116BNA030

116BNA036

116BNA042

116BNA048

116BNA060

116BNA018

116BNA061

116BNA048

116BNA049

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

3 7/8"
3 7/8"

28 5/16"
32 5/16"
28 5/16"
39 1/8"
32 5/16"
45 15/16"
28 11/16"
45 15/16"
39 1/8"
39 1/8"

31 3/16"
35"
35"
35"
35"
25 3/4"
35"
35"
35"

35" X 35"

26" X 26"

31 1/2" X 31 1/2"

24,30

X = YES
O = NO

3 3/4"

28 11/16"

23 1/8"
31 3/16"

SQ.

A

7/8"

7/8"

7/8"

3/4"

7/8"

7/8"

7/8"

7/8"

3/4"

3/4"

3/4"

D

AIR DISCHARGE

3 7/8"

3 7/8"

3 7/8"

3 3/4"

3 7/8"

3 7/8"

3 3/4"

3 3/4"

C

A

B

MINIMUM
MOUNTING PAD
DIMENSIONS

36, 48, 49, 60, 61

18

3 1/2"

DVAPOR LINE CONN.

C

3/8"
LIQUID LINE CONN.

FIELD POWER SUPPLY CONN.
7/8" HOLE WITH
1 1/8" KNOCKOUT

FIELD CONTROL
SUPPLY CONN.
7/8" HOLE

O

O

O

O

O

O

O

O

O

O

O

X

X

X

X

X

X

X

X

X

X

X

208-230-1-60

UNIT SIZE

B

A

116BNA018

ELECTRICAL
CHARACTERISTICS

230-1-60

SERIES

208/230-3-60

UNIT

DIMENSIONS -- ENGLISH

460-3-60

6 9/16"

6 9/16"

6 9/16"

4 7/16"

6 9/16"

6 9/16"

6 9/16"

6 9/16"

6 9/16"

6 9/16"

4 7/16"

E

28 7/16"

28 7/16"

28 7/16"

21 1/4"

28 7/16"

28 7/16"

28 7/16"

28 7/16"

24 11/16"

24 11/16"

18 1/16"

F

1 7/8"

9 1/8"

9 1/8"

9 1/8"

7 13/16"

9 1/8"

9 1/8"

9 1/8"

9 1/8"

9 1/8"

9 1/8"

7 13/16"

G

P

2 15/16"

2 15/16"

2 15/16"

2 13/16"

2 15/16"

2 15/16"

2 15/16"

2 15/16"

2 13/16"

2 13/16"

2 13/16"

K

3"

AIR IN

5/16"

17 1/2"

16 1/2"

16 1/2"

13 5/8"

16 1/2"

17"

16 1/2"

16"

15 1/2"

16"

13"

M

K

16 1/2"

16 1/2"

17"

13 1/2"

17"

17 1/2"

17 1/2"

16"

16"

16"

12"

N

3/8" TIEDOWN KNOCKOUTS
(2) PLACES

L

5/8"

5/8"

5/8"

1/2"

5/8"

5/8"

5/8"

5/8"

1/2"

1/2"

1/2"

L

G

M

15"

15"

16 1/4"

12 3/4"

16 1/4"

14 1/4"

17 1/2"

13"

14 1/4"

13"

13"

P

116B

AIR IN

AIR IN

231

264

272

125

272

231

213

165

153

147

118

AIR
DISCHARGE

269

317

310

154

310

274

254

204

188

183

141

OPERATING
SHIPPING
WEIGHT (lbs) WEIGHT (lbs)

E

N

F

36 1/8" X 39 5/16" X 42 3/4"

36 1/8" X 39 5/16" X 42 3/4"

36 1/8" X 39 15/16" X 49 9/16"

26 7/8" X 30 1/16" X 32 9/16"

36 1/8" X 39 5/16" X 49 9/16"

36 1/8" X 39 5/16" X 35 15/16"

36 1/8" X 39 5/16" X 42 3/4"

36 1/8" X 39 5/16" X 32 9/16"

32 3/8" X 35 1/2" X 35 15/16"

32 3/8" X 35 1/2" X 32 9/16"

24 1/4" X 27 3/8" X 32 9/16"

AIR IN

SHIPPING
DIMENSIONS (L x W x H)

10

A

A

A

A

A

A

B

A

B

A

116BNA024

116BNA030

116BNA036

116BNA042

116BNA048

116BNA060

116BNA018

116BNA061

116BNA048

116BNA049

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

O

88.9

993.8

889.0

660.4 X 660.4

800.1 X 800.1

889.0 X 889.0

18

24,30

36, 48, 49, 60, 61

X = YES
O = NO

719.2

889.0

728.7
1166.8
993.8
993.8

654.0
889.0
889.0
889.0

820.8

820.8

792.2

1166.8

719.2

792.2

889.0

728.7

587.3

889.0

B

A

MINIMUM
MOUNTING PAD
DIMENSIONS

DVAPOR LINE CONN.

C

9.53
LIQUID LINE CONN.

FIELD POWER SUPPLY CONN.
22.23 HOLE WITH
28.58 KNOCKOUT

FIELD CONTROL
SUPPLY CONN.
22.23 HOLE

O

O

O

O

O

O

O

O

O

O

O

X

X

X

X

X

X

X

X

X

X

X

208-230-1-60

UNIT SIZE

B

A

116BNA018

ELECTRICAL
CHARACTERISTICS

230-1-60

SERIES

208/230-3-60

UNIT

DIMENSIONS -- SI

460-3-60

SQ.

A

22.2

22.2

22.2

19.0

22.2

22.2

22.2

22.2

19.0

19.0

19.0

D

AIR DISCHARGE

98.6

98.6

98.6

95.2

98.6

98.6

98.6

98.6

95.2

95.2

95.2

C

166.7

166.7

166.7

112.7

166.7

166.7

166.7

166.7

166.7

166.7

112.7

E

722.3

722.3

722.3

539.8

722.3

722.3

722.3

722.3

627.1

627.1

458.8

F

47.6

231.8

231.8

231.8

198.4

231.8

231.8

231.8

231.8

231.8

231.8

198.4

G

P

74.6

74.6

74.6

71.4

74.6

74.6

74.6

74.6

71.4

71.4

71.4

K

76.2

L

AIR IN

8.0

444.5

419.1

419.1

346.1

419.1

431.8

419.1

406.4

393.7

406.4

330.2

M

K

419.1

419.1

431.8

342.9

431.8

444.5

444.5

406.4

406.4

406.4

304.8

N

9.53 TIEDOWN KNOCKOUTS
(2) PLACES

15.9

15.9

15.9

12.7

15.9

15.9

15.9

15.9

12.7

12.7

12.7

L

G

M

381.0

381.0

412.8

323.9

412.8

362.0

444.5

330.2

362.0

330.2

330.2

P

AIR IN

AIR IN

104.8

119.7

123.4

56.7

123.4

104.8

96.4

74.8

69.3

66.5

53.4

AIR
DISCHARGE

122.0

143.8

140.6

69.9

140.6

124.3

115.2

92.5

85.2

82.8

64.0

OPERATING
SHIPPING
WEIGHT (Kgs) WEIGHT (Kgs)

116B

E

N

F

917.6 X 998.6 X 1085.8

917.6 X 998.6 X 1085.8

917.6 X 998.6 X 1258.9

682.6 X 763.6 X 827.1

917.6 X 998.6 X 1258.9

917.6 X 998.6 X 912.8

917.6 X 998.6 X 1085.8

917.6 X 998.6 X 827.1

822.3 X 901.7 X 912.8

822.3 X 901.7 X 827.1

616.0 X 695.3 X 827.1

AIR IN

SHIPPING
DIMENSIONS (L x W x H)

11

24”
(609.6)
Service

12”
(304.8)

Note: Numbers in ( ) = mm

18”
(457.2)

24”
(609.6)
Service

Wall
6”
(152.4)

18”
(457.2)

12”
(304.8)

24”
(609.6)
Service

Wall

18”
(457.2)

12”
(304.8)

Clearances (various examples)

24”
(609.6)
Service

12”
(304.8)

24”
(609.6)
Service

Wall

6”
(152.4)

116B

IMPORTANT: When installing multiple units in an alcove, roof well, or partially enclosed area, ensure there is adequate ventilation to prevent re--circulation of discharge air.

CLEARANCES

Wall

TESTED AHRI COMBINATION RATINGS*
NOTE: Ratings contained in this document are subject to change at any time.
For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org
Additional ratings and system combinations can be accessed via the Bryant database at:
http://cactaxcredits.info/bryant-ratings/hp_ratings_srch.php
Equipment performance calculator can be accessed at: http://rpmobbry.wrightsoft.com/

116B

Model Number
116BNA018****B
116BNA024****A
116BNA030****A
116BNA036****A
116BNA042****A
116BNA048****B
116BNA049****A
116BNA060****A
116BNA061****A

Indoor Coil Model Number
CNPV*1917A**
CNPV*3117A**
CNPV*3117A**
CNPV*3717A**
CNPV*4324A**
CAP**6025A**
CAP**6025A**
CNPV*6124A**
CNPV*6124A**

Furnace Model Number

Cooling Capacity
18,000
23,600
28,600
34,400
41,500
46,000
48,000
56,000
59,500

EER
12.0
12.0
12.0
12.0
12.0
12.0
11.5
12.0
12.0

SEER
14.5
14.5
14.5
14.5
14.5
14.5
14.0
14.5
14.5

* AHRI = Air Conditioning, Heating & Refrigeration Institute
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.

12

13

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

See notes on pg. 17

900

800

700

CFM

EWB
° F (° C)

EVAPORATOR AIR

675

600

525

CFM

EWB
° F (° C)

EVAPORATOR AIR

75 (23.9)

10.39
12.69
12.20
14.92
17.19
10.93
13.55
13.02
16.11
17.99
11.45
14.38
13.79
18.68
18.66

Sens‡

28.21
25.63
23.72
23.32
22.68
28.72
26.16
24.23
23.91
23.70
29.09
26.54
24.61
24.60
24.56

Total

13.70
16.78
16.13
19.80
22.68
14.43
17.95
17.22
21.38
23.70
15.12
19.08
18.27
24.60
24.56

Sens‡

Capacity MBtuh†

21.52
19.59
18.14
17.80
17.19
21.94
19.99
18.55
18.25
17.99
22.24
20.29
18.85
18.68
18.66

Total

Capacity MBtuh†

75 (23.9)

1.55
1.55
1.55
1.55
1.55
1.58
1.58
1.58
1.58
1.58
1.62
1.62
1.62
1.62
1.62

Total
System
KW**

1.18
1.18
1.18
1.18
1.18
1.21
1.20
1.20
1.20
1.20
1.23
1.23
1.23
1.23
1.23

Total
System
KW**

85 (29.4)

85 (29.4)

10.05
12.32
11.84
14.56
16.54
10.58
13.19
12.65
15.72
17.28
11.09
14.01
13.42
17.93
17.90

Sens‡

26.92
24.44
22.62
22.25
21.84
27.38
24.91
23.08
22.85
22.79
27.72
25.25
23.42
23.62
23.59

Total
13.25
16.32
15.67
19.34
21.84
13.97
17.49
16.75
22.74
22.79
14.67
18.60
17.79
23.62
23.59

Sens‡

Capacity MBtuh†

20.55
18.66
17.28
16.97
16.54
20.92
19.03
17.64
17.39
17.28
21.19
19.30
17.91
17.93
17.90

Total

Capacity MBtuh†

DETAILED COOLING CAPACITIES#

1.65
1.64
1.63
1.63
1.63
1.68
1.67
1.66
1.66
1.66
1.71
1.70
1.69
1.69
1.69

116B

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
116BNA024****A Outdoor Section With CNPV*3117A** Indoor Section
1.74
25.54
12.78
1.94
24.09
12.29
2.16
1.73
23.19
15.85
1.93
21.87
15.36
2.15
1.73
21.46
15.20
1.92
20.22
14.70
2.14
1.73
21.14
18.86
1.92
20.00
19.96
2.14
1.73
20.93
20.93
1.92
19.96
19.96
2.14
1.77
25.95
13.49
1.98
24.44
12.99
2.20
1.77
23.60
17.00
1.97
22.22
16.49
2.19
1.77
21.86
16.27
1.96
20.58
15.76
2.18
1.77
21.85
21.85
1.96
20.81
20.81
2.18
1.76
21.82
21.82
1.96
20.78
20.78
2.18
1.81
26.23
14.18
2.02
24.68
13.67
2.24
1.81
23.90
18.11
2.01
22.48
17.59
2.22
1.80
22.16
17.30
2.00
20.84
16.78
2.22
1.80
22.58
22.58
2.00
21.48
21.48
2.22
1.80
22.55
22.55
2.00
21.45
21.45
2.22

116BNA018****B Outdoor Section With CNPV*1917A** Indoor Section
1.32
19.48
9.68
1.48
18.35
9.29
1.32
17.68
11.95
1.47
16.64
11.56
1.32
16.37
11.47
1.47
15.40
11.07
1.31
16.08
14.18
1.47
15.17
13.78
1.31
15.84
15.84
1.46
15.09
15.09
1.35
19.82
10.21
1.51
18.63
9.81
1.35
18.00
12.80
1.50
16.92
12.40
1.34
16.68
12.26
1.49
15.68
11.86
1.34
16.55
16.55
1.49
15.74
15.74
1.34
16.53
16.53
1.49
15.72
15.72
1.38
20.06
10.72
1.54
18.83
10.32
1.37
18.24
13.62
1.53
17.13
13.22
1.37
16.92
13.03
1.52
15.88
12.61
1.37
17.12
17.12
1.52
16.26
16.26
1.37
17.09
17.09
1.52
16.24
16.24

Total
System
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
115 (46.1)

115 (46.1)

8.88
11.14
10.66
14.30
14.27
9.40
11.98
11.44
14.87
14.85
9.90
12.79
12.18
15.33
15.31

Sens‡

22.56
20.47
18.91
18.95
18.92
22.85
20.76
19.21
19.69
19.66
23.05
20.98
19.45
20.29
20.27

Total

11.77
14.84
14.18
18.95
18.92
12.47
15.96
15.22
19.69
19.66
13.15
17.05
16.23
20.29
20.27

Sens‡

Capacity MBtuh†

17.15
15.54
14.37
14.30
14.27
17.39
15.78
14.60
14.87
14.85
17.55
15.95
14.78
15.33
15.31

Total

Capacity MBtuh†

2.41
2.39
2.38
2.38
2.38
2.44
2.43
2.42
2.42
2.43
2.48
2.47
2.46
2.47
2.47

Total
System
KW**

1.84
1.83
1.82
1.82
1.82
1.87
1.86
1.85
1.85
1.85
1.90
1.89
1.88
1.88
1.88

Total
System
KW**

125 (51.7)

125 (51.7)

8.46
10.72
10.22
13.42
13.40
8.97
11.54
10.99
13.93
13.91
9.47
12.34
11.73
14.35
14.33

Sens‡

20.94
18.98
17.52
17.82
17.79
21.17
19.23
17.78
18.49
18.46
21.32
19.42
17.98
19.02
18.99

Total

11.24
14.29
13.62
17.82
17.79
11.93
15.41
14.66
18.49
18.46
12.60
16.48
15.65
19.02
18.99

Sens‡

Capacity MBtuh†

15.88
14.37
13.27
13.42
13.40
16.07
14.57
13.47
13.93
13.91
16.20
14.72
13.63
14.35
14.33

Total

Capacity MBtuh†

2.68
2.67
2.67
2.67
2.67
2.72
2.71
2.70
2.71
2.71
2.76
2.75
2.74
2.75
2.75

Total
System
KW**

2.06
2.05
2.04
2.04
2.04
2.09
2.08
2.07
2.07
2.07
2.12
2.10
2.10
2.10
2.10

Total
System
KW**

14

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

EWB
° F (° C)

See notes on pg. 17

1350

1200

1050

CFM

EVAPORATOR AIR

1125

1000

875

CFM

EWB
° F (° C)

EVAPORATOR AIR

75 (23.9)

16.61
20.47
19.68
24.28
27.76
17.49
21.88
20.99
28.77
28.93
18.33
23.24
22.25
29.93
29.89

Sens‡

41.06
37.33
34.65
34.09
33.38
41.77
38.02
35.31
34.94
34.80
42.28
38.51
35.80
36.01
35.96

Total

20.24
24.93
23.97
29.55
33.38
21.32
26.65
25.57
31.83
34.80
22.34
28.29
27.10
36.01
35.96

Sens‡

Capacity MBtuh†

34.09
30.99
28.76
28.31
27.76
34.67
31.55
29.30
29.03
28.93
35.09
31.96
29.70
29.93
29.89

Total

Capacity MBtuh†

75 (23.9)

2.39
2.37
2.36
2.36
2.35
2.45
2.43
2.42
2.42
2.42
2.52
2.50
2.48
2.48
2.48

Total
System
KW**

1.91
1.92
1.93
1.93
1.93
1.96
1.97
1.97
1.97
1.97
2.00
2.01
2.02
2.02
2.02

Total
System
KW**

85 (29.4)

16.09
19.95
19.16
23.74
26.76
16.96
21.35
20.46
27.89
27.84
17.80
22.70
21.71
28.78
28.74

Sens‡

39.22
35.65
33.08
32.58
32.16
39.84
36.25
33.66
33.53
33.47
40.29
36.70
34.11
34.61
34.56

Total
19.60
24.28
23.32
28.89
32.16
20.66
25.99
24.91
33.53
33.47
21.68
27.62
26.43
34.61
34.56

Sens‡

Capacity MBtuh†

32.58
29.61
27.47
27.08
26.76
33.09
30.10
27.95
27.89
27.84
33.45
30.47
28.32
28.78
28.74

Total

Capacity MBtuh†

85 (29.4)

116BNA036****A Outdoor Section With CNPV*3717A** Indoor Section
2.65
37.27
18.94
2.95
35.20
18.24
2.63
33.87
23.61
2.93
31.96
22.90
2.62
31.40
22.64
2.92
29.62
21.92
2.62
31.00
28.17
2.91
29.47
29.47
2.62
30.85
30.85
2.91
29.43
29.43
2.72
37.82
19.99
3.01
35.67
19.28
2.70
34.40
25.30
2.99
32.44
24.58
2.69
31.93
24.22
2.98
30.09
23.48
2.69
32.12
32.12
2.98
30.60
30.60
2.68
32.07
32.07
2.98
30.55
30.55
2.78
38.19
20.99
3.08
35.98
20.27
2.76
34.80
26.93
3.05
32.78
26.19
2.75
32.32
25.72
3.04
30.43
24.97
2.75
33.12
33.12
3.05
31.51
31.51
2.75
33.08
33.08
3.04
31.47
31.47

Total
System
KW**

3.28
3.26
3.25
3.25
3.25
3.35
3.32
3.31
3.32
3.32
3.41
3.39
3.38
3.38
3.38

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
116BNA030****A Outdoor Section With CNPV*3117A** Indoor Section
2.11
31.00
15.56
2.33
29.32
15.00
2.59
2.12
28.16
19.41
2.34
26.61
18.84
2.59
2.12
26.11
18.61
2.34
24.65
18.03
2.59
2.12
25.80
23.16
2.34
24.56
24.56
2.59
2.12
25.69
25.69
2.34
24.52
24.52
2.59
2.15
31.45
16.42
2.38
29.71
15.86
2.63
2.16
28.60
20.80
2.38
27.00
20.22
2.64
2.17
26.55
19.90
2.39
25.04
19.31
2.64
2.16
26.74
26.74
2.39
25.50
25.50
2.64
2.16
26.70
26.70
2.39
25.46
25.46
2.64
2.20
31.76
17.25
2.42
29.97
16.67
2.68
2.21
28.93
22.14
2.43
27.29
21.54
2.68
2.21
26.87
21.14
2.43
25.32
20.53
2.69
2.21
27.57
27.57
2.43
26.26
26.26
2.68
2.21
27.53
27.53
2.43
26.22
26.22
2.68

DETAILED COOLING CAPACITIES# (CONT.)

116B

115 (46.1)

115 (46.1)

14.40
18.23
17.41
23.28
23.25
15.25
19.60
18.68
24.14
24.11
16.06
20.90
19.88
24.83
24.80

Sens‡

33.01
29.95
27.73
27.95
27.91
33.39
30.35
28.13
28.97
28.93
33.65
30.65
28.44
29.80
29.76

Total

17.50
22.15
21.17
27.95
27.91
18.53
23.82
22.71
28.97
28.93
19.52
25.41
24.18
29.80
29.76

Sens‡

Capacity MBtuh†

27.51
24.93
23.07
23.28
23.25
27.83
25.27
23.40
24.14
24.11
28.04
25.52
23.66
24.83
24.80

Total

Capacity MBtuh†

3.66
3.65
3.64
3.64
3.64
3.73
3.71
3.70
3.70
3.70
3.79
3.77
3.76
3.77
3.77

Total
System
KW**

2.88
2.88
2.88
2.88
2.88
2.93
2.93
2.93
2.93
2.93
2.97
2.97
2.98
2.97
2.97

Total
System
KW**

125 (51.7)

125 (51.7)

13.76
17.56
16.73
21.87
21.83
14.60
18.92
17.98
22.64
22.61
15.41
20.20
19.15
23.26
23.23

Sens‡

30.65
27.79
25.71
26.29
26.25
30.96
28.13
26.05
27.21
27.17
31.16
28.39
26.32
27.94
27.91

Total

16.73
21.36
20.37
26.29
26.25
17.75
23.01
21.89
27.21
27.17
18.72
24.57
23.32
27.94
27.91

Sens‡

Capacity MBtuh†

25.53
23.10
21.33
21.87
21.83
25.79
23.39
21.63
22.64
22.61
25.96
23.62
21.87
23.26
23.23

Total

Capacity MBtuh†

4.11
4.09
4.09
4.09
4.09
4.17
4.15
4.15
4.15
4.15
4.23
4.22
4.21
4.21
4.21

Total
System
KW**

3.22
3.22
3.22
3.21
3.21
3.26
3.26
3.26
3.26
3.26
3.31
3.31
3.31
3.31
3.31

Total
System
KW**

15

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

EWB
° F (° C)

See notes on pg. 17

1800

1600

1400

CFM

EVAPORATOR AIR

1575

1400

1225

CFM

EWB
° F (° C)

EVAPORATOR AIR

75 (23.9)

24.05
29.64
28.52
35.16
40.45
25.29
31.63
30.38
37.80
42.10
26.46
33.54
32.15
43.52
43.46

Sens‡

55.71
50.48
46.73
45.93
45.05
56.66
51.35
47.56
47.06
46.92
57.33
51.99
48.17
48.51
48.45

Total

27.90
34.32
32.94
40.65
45.05
29.33
36.61
35.07
46.71
46.92
30.68
38.81
37.10
48.51
48.45

Sens‡

Capacity MBtuh†

49.58
45.17
41.97
41.32
40.45
50.40
45.95
42.74
42.31
42.10
50.98
46.53
43.31
43.52
43.46

Total

Capacity MBtuh†

75 (23.9)

2.67
2.83
2.93
2.94
2.96
2.72
2.88
2.99
3.00
3.00
2.77
2.94
3.06
3.04
3.04

Total
System
KW**

2.77
2.75
2.74
2.74
2.73
2.85
2.82
2.81
2.81
2.81
2.92
2.90
2.88
2.88
2.88

Total
System
KW**

85 (29.4)

23.28
28.86
27.75
34.36
38.96
24.50
30.84
29.59
40.55
40.50
25.66
32.73
31.35
41.82
41.76

Sens‡

52.91
47.96
44.44
43.75
43.28
53.70
48.71
45.15
45.06
44.99
54.27
49.25
45.68
46.44
46.38

Total
26.91
33.34
31.98
39.65
43.28
28.32
35.62
34.09
45.06
44.99
29.65
37.79
36.10
46.44
46.38

Sens‡

Capacity MBtuh†

47.31
43.10
40.06
39.49
38.96
48.02
43.80
40.75
40.55
40.50
48.52
44.31
41.25
41.82
41.76

Total

Capacity MBtuh†

85 (29.4)

116BNA048****B Outdoor Section With CAP**6024* Indoor Section
3.09
50.01
25.90
3.52
47.00
24.87
3.22
45.37
32.35
3.61
42.67
31.33
3.29
42.06
31.01
3.66
39.59
30.00
3.30
41.55
41.29
3.66
39.51
39.51
3.31
41.43
41.43
3.66
39.45
39.45
3.15
50.67
27.29
3.59
47.54
26.24
3.28
46.00
34.60
3.68
43.20
33.56
3.36
42.68
33.09
3.74
40.11
32.06
3.36
43.04
43.04
3.73
40.91
40.91
3.36
42.98
42.98
3.73
40.85
40.85
3.22
51.13
28.60
3.66
47.88
27.53
3.35
46.46
36.75
3.76
43.57
35.67
3.44
43.11
35.07
3.82
40.47
34.01
3.41
44.29
44.29
3.79
42.02
42.02
3.42
44.24
44.24
3.79
41.97
41.97

Total
System
KW**

116B

3.95
4.01
4.05
4.04
4.04
4.03
4.09
4.13
4.12
4.12
4.11
4.17
4.21
4.19
4.19

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
116BNA042****A Outdoor Section With CNPV*4324A** Indoor Section
3.07
44.88
22.46
3.42
42.30
21.59
3.80
3.05
40.90
28.04
3.38
38.55
27.18
3.76
3.03
38.02
26.93
3.36
35.83
26.06
3.74
3.03
37.56
33.49
3.36
35.65
35.65
3.74
3.03
37.34
37.34
3.36
35.60
35.60
3.74
3.15
45.48
23.66
3.49
42.82
22.79
3.87
3.12
41.50
30.00
3.46
39.07
29.12
3.84
3.10
38.61
28.75
3.44
36.36
27.87
3.82
3.10
38.82
38.82
3.44
36.94
36.94
3.82
3.10
38.76
38.76
3.44
36.89
36.89
3.82
3.22
45.91
24.82
3.56
43.16
23.93
3.95
3.19
41.95
31.88
3.53
39.45
30.98
3.91
3.17
39.06
30.49
3.51
36.74
29.58
3.89
3.18
39.96
39.96
3.52
37.98
37.98
3.90
3.18
39.91
39.91
3.52
37.93
37.93
3.90

DETAILED COOLING CAPACITIES# (CONT.)
115 (46.1)

115 (46.1)

20.70
26.27
25.16
33.78
33.73
21.88
28.20
26.94
34.93
34.89
23.01
30.02
28.62
35.86
35.81

Sens‡

43.85
39.85
36.99
37.39
37.34
44.26
40.27
37.41
38.62
38.57
44.52
40.57
37.72
39.60
39.55

Total

23.81
30.28
28.96
37.39
37.34
25.15
32.47
30.98
38.62
38.57
26.43
34.55
32.88
39.60
39.55

Sens‡

Capacity MBtuh†

39.58
36.07
33.53
33.78
33.73
39.99
36.51
33.97
34.93
34.89
40.25
36.83
34.30
35.86
35.81

Total

Capacity MBtuh†

4.41
4.44
4.46
4.46
4.46
4.49
4.53
4.55
4.54
4.54
4.57
4.62
4.64
4.62
4.62

Total
System
KW**

4.23
4.19
4.17
4.17
4.17
4.30
4.26
4.24
4.25
4.25
4.37
4.34
4.31
4.33
4.33

Total
System
KW**

125 (51.7)

125 (51.7)

19.77
25.33
24.21
31.76
31.72
20.94
27.23
25.96
32.78
32.74
22.06
29.02
27.60
33.58
33.55

Sens‡

40.51
36.84
34.22
35.08
35.03
40.81
37.17
34.56
36.15
36.11
40.96
37.43
34.82
36.98
36.94

Total

22.69
29.16
27.85
35.08
35.03
24.02
31.32
29.83
36.15
36.11
25.28
33.33
31.65
36.98
36.94

Sens‡

Capacity MBtuh†

36.71
33.47
31.10
31.76
31.72
37.02
33.83
31.47
32.78
32.74
37.22
34.11
31.77
33.58
33.55

Total

Capacity MBtuh†

4.89
4.91
4.92
4.91
4.91
4.98
5.00
5.01
5.00
5.00
5.07
5.09
5.10
5.09
5.09

Total
System
KW**

4.70
4.66
4.64
4.64
4.64
4.77
4.74
4.71
4.72
4.72
4.85
4.81
4.78
4.80
4.80

Total
System
KW**

16

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
63 (17.2)††
62 (16.7)
57 (13.9)

EWB
° F (° C)

See notes on pg. 17

2250

2000

1750

CFM

EVAPORATOR AIR

1800

1600

1400

CFM

EWB
° F (° C)

EVAPORATOR AIR

75 (23.9)

29.08
35.60
34.57
42.09
46.53
30.51
37.89
36.71
45.22
48.50
31.86
40.07
38.76
49.72
50.13

Sens‡

67.62
61.61
57.26
56.64
56.19
68.55
62.54
58.17
58.38
58.30
69.20
63.21
58.84
60.10
60.03

Total

33.62
41.91
40.25
50.02
56.19
35.38
44.78
42.92
58.38
58.30
37.05
47.52
45.45
60.10
60.03

Sens‡

Capacity MBtuh†

57.54
52.60
49.11
48.14
46.53
58.62
53.60
50.08
49.23
48.50
59.40
54.34
50.79
50.22
50.13

Total

Capacity MBtuh†

75 (23.9)

3.61
3.60
3.60
3.59
3.59
3.71
3.70
3.69
3.69
3.69
3.81
3.80
3.79
3.79
3.79

Total
System
KW**

3.21
3.24
3.26
3.26
3.26
3.27
3.30
3.32
3.32
3.33
3.33
3.36
3.39
3.39
3.39

Total
System
KW**

85 (29.4)

28.10
34.61
33.58
41.09
44.81
29.51
36.88
35.70
44.16
46.64
30.84
39.04
37.73
48.15
48.15

Sens‡

64.17
58.55
54.46
54.07
53.95
64.97
59.34
55.24
55.95
55.88
65.50
59.93
55.83
57.51
57.44

Total
32.46
40.77
39.14
53.77
53.95
34.21
43.61
41.77
55.95
55.88
35.85
46.32
44.27
57.51
57.44

Sens‡

Capacity MBtuh†

54.91
50.19
46.86
45.97
44.81
55.85
51.08
47.72
46.99
46.64
56.54
51.73
48.35
48.15
48.15

Total

Capacity MBtuh†

85 (29.4)

116BNA060****A Outdoor Section With CNPV*6124A** Indoor Section
4.00
60.58
31.27
4.41
56.79
30.03
3.97
55.32
39.59
4.38
51.90
38.34
3.96
51.50
37.96
4.36
48.36
36.73
3.96
51.61
51.61
4.36
48.99
48.99
3.96
51.53
51.53
4.36
48.93
48.93
4.10
61.24
32.99
4.51
57.31
31.73
4.07
56.00
42.40
4.48
52.47
41.12
4.06
52.18
40.57
4.46
48.93
39.29
4.06
53.34
53.34
4.47
50.54
50.54
4.06
53.28
53.28
4.46
50.48
50.48
4.20
61.65
34.62
4.61
57.62
33.34
4.17
56.49
45.07
4.58
52.89
43.73
4.16
52.68
43.02
4.56
49.37
41.69
4.16
54.74
54.74
4.57
51.77
51.77
4.16
54.68
54.68
4.57
51.71
51.71

Total
System
KW**

4.86
4.83
4.80
4.81
4.81
4.96
4.93
4.90
4.92
4.92
5.06
5.03
5.01
5.02
5.02

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
116BNA049****A Outdoor Section With CAP**6024A* Indoor Section
3.66
52.22
27.11
4.12
49.43
26.10
4.59
3.67
47.73
33.62
4.10
45.16
32.59
4.55
3.67
44.56
32.57
4.08
42.14
31.53
4.53
3.66
43.75
40.07
4.08
41.45
38.99
4.52
3.66
43.02
43.02
4.07
41.13
41.13
4.52
3.73
53.04
28.50
4.19
50.14
27.47
4.66
3.74
48.50
35.86
4.17
45.83
34.82
4.63
3.74
45.31
34.68
4.16
42.81
33.63
4.61
3.74
44.76
44.49
4.16
42.69
42.69
4.61
3.74
44.72
44.72
4.16
42.69
42.69
4.61
3.80
53.64
29.82
4.26
50.65
28.78
4.74
3.81
49.07
38.01
4.25
46.33
36.96
4.71
3.81
45.87
36.70
4.23
43.30
35.63
4.69
3.81
46.11
46.11
4.24
43.96
43.96
4.69
3.81
46.11
46.11
4.24
43.96
43.96
4.69

DETAILED COOLING CAPACITIES# (CONT.)

116B

115 (46.1)

115 (46.1)

25.03
31.50
30.44
39.06
39.07
26.39
33.72
32.51
40.49
40.50
27.68
35.84
34.49
41.64
41.64

Sens‡

52.77
48.28
45.00
46.15
46.09
53.16
48.74
45.49
47.51
47.45
53.39
49.12
45.89
48.57
48.52

Total

28.73
37.03
35.42
46.15
46.09
30.40
39.76
37.93
47.51
47.45
32.00
42.29
40.23
48.57
48.52

Sens‡

Capacity MBtuh†

46.46
42.41
39.56
39.06
39.07
47.06
42.99
40.14
40.49
40.50
47.47
43.41
40.56
41.64
41.64

Total

Capacity MBtuh†

5.37
5.33
5.31
5.32
5.32
5.47
5.43
5.41
5.42
5.42
5.57
5.53
5.51
5.53
5.53

Total
System
KW**

5.09
5.06
5.03
5.02
5.02
5.17
5.13
5.11
5.11
5.11
5.25
5.21
5.19
5.19
5.19

Total
System
KW**

125 (51.7)

125 (51.7)

23.88
30.33
29.25
36.78
36.78
25.22
32.52
31.30
38.05
38.05
26.50
34.61
33.24
39.07
39.07

Sens‡

48.49
44.39
41.41
43.04
42.99
48.76
44.80
41.84
44.19
44.14
48.89
45.19
42.31
45.09
45.04

Total

27.36
35.62
34.01
43.04
42.99
29.01
38.28
36.44
44.19
44.14
30.59
44.77
42.31
45.09
45.04

Sens‡

Capacity MBtuh†

43.18
39.40
36.72
36.78
36.78
43.67
39.88
37.20
38.05
38.05
43.99
40.23
37.56
39.07
39.07

Total

Capacity MBtuh†

5.94
5.90
5.88
5.90
5.90
6.04
6.01
5.99
6.00
6.00
6.14
6.11
6.09
6.11
6.11

Total
System
KW**

5.66
5.62
5.60
5.60
5.60
5.74
5.70
5.68
5.68
5.68
5.81
5.78
5.76
5.77
5.77

Total
System
KW**

17

72 (22.2)
67 (19.4)
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
62 (16.7)
57 (13.9)
72 (22.2)
67 (19.4)
62 (16.7)
57 (13.9)

68.26
62.16
56.92
55.79
69.37
63.22
58.30
58.04
70.16
64.02
59.97
59.89

Total

35.40
43.65
51.79
55.79
37.22
46.57
55.64
58.04
38.93
49.36
59.97
59.89

Sens‡

Capacity MBtuh†

75 (23.9)

3.65
3.59
3.54
3.53
3.75
3.69
3.64
3.64
3.85
3.79
3.75
3.75

Total
System
KW**
65.62
59.80
54.89
54.23
66.58
60.75
56.40
56.32
67.25
61.43
58.12
58.04

Total
34.24
42.52
50.66
54.23
36.03
45.42
56.40
56.32
37.73
48.19
58.12
58.04

Sens‡

Capacity MBtuh†

85 (29.4)

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
95 (35)
105 (40.6)
Total
Total
Total
Capacity MBtuh†
Capacity MBtuh†
System
System
System
Total
Sens‡
Total
Sens‡
KW**
KW**
KW**
116BNA061****A Outdoor Section With CNPV*6124A**+TDR Indoor Section
4.19
62.70
33.02
4.80
59.44
31.72
5.50
4.12
57.18
41.32
4.72
54.27
40.05
5.42
4.07
52.67
49.40
4.67
50.45
50.45
5.37
4.06
52.43
52.43
4.67
50.37
50.37
5.37
4.29
63.50
34.78
4.91
60.12
33.47
5.61
4.22
58.00
44.20
4.83
54.96
42.90
5.54
4.18
54.43
54.43
4.79
52.18
52.18
5.50
4.17
54.35
54.35
4.79
52.12
52.12
5.50
4.39
64.06
36.47
5.01
60.55
35.14
5.72
4.32
58.58
46.94
4.94
55.46
45.61
5.65
4.29
55.99
55.99
4.91
53.58
53.58
5.62
4.29
55.93
55.93
4.91
53.52
53.52
5.62
115 (46.1)

55.84
51.03
48.08
48.01
56.36
51.60
49.62
49.56
56.68
52.01
50.85
50.79

Total
30.35
38.69
48.08
48.01
32.08
41.51
49.62
49.56
33.73
44.17
50.85
50.79

Sens‡

Capacity MBtuh†

6.31
6.24
6.19
6.19
6.43
6.35
6.32
6.32
6.54
6.47
6.45
6.45

Total
System
KW**

116B

{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below
80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C).
# Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240--- 2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity
may occur.
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor air temperatures are at 80_F edb.
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
EWB — Entering Wet Bulb

2250

2000

1750

CFM

EWB
° F (° C)

EVAPORATOR AIR

DETAILED COOLING CAPACITIES# (CONT.)
125 (51.7)

51.84
47.43
45.35
45.29
52.22
47.88
46.69
46.64
52.43
48.25
47.74
47.69

Total

28.89
37.23
45.35
45.29
30.60
40.00
46.69
46.64
32.24
42.59
47.74
47.69

Sens‡

Capacity MBtuh†

7.25
7.18
7.15
7.15
7.37
7.30
7.28
7.28
7.48
7.41
7.41
7.40

Total
System
KW**

CONDENSER ONLY RATINGS
SST
° F (° C)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)

116B

55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

55 (12.78)

65 (18.33)

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

15.70
66.60
0.75
17.50
67.80
0.75
19.40
69.00
0.74
21.50
70.40
0.74
23.60
71.60
0.73
25.90
73.00
0.73

14.90
76.20
0.87
16.60
77.30
0.87
18.40
78.50
0.87
20.30
79.70
0.86
22.40
80.90
0.86
24.50
82.10
0.86

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

20.30
66.10
1.00
22.60
67.20
0.99
24.90
68.40
0.98
27.40
69.60
0.97
30.10
70.80
0.96
33.00
72.10
0.95

19.40
75.80
1.15
21.40
76.80
1.14
23.70
77.90
1.14
26.00
79.00
1.14
28.60
80.10
1.13
31.30
81.30
1.13

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

24.90
68.10
1.27
27.50
69.40
1.28
30.30
70.70
1.29
33.30
72.00
1.29
36.50
73.50
1.29
39.90
75.00
1.29

23.50
77.50
1.43
26.00
78.70
1.44
28.60
79.90
1.44
31.50
81.20
1.44
34.50
82.50
1.44
37.80
84.00
1.44

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
116BNA018****B
14.10
13.20
12.30
11.30
85.80
95.30
104.80
114.30
0.99
1.12
1.26
1.41
15.70
14.70
13.70
12.60
86.80
96.30
105.70
115.10
0.99
1.12
1.26
1.42
17.40
16.30
15.20
14.00
87.90
97.30
106.60
115.90
0.99
1.12
1.26
1.42
19.20
18.00
16.70
15.50
89.00
98.30
107.60
116.90
0.99
1.13
1.27
1.43
21.10
19.70
18.40
17.00
90.10
99.40
108.60
117.80
1.00
1.13
1.28
1.44
23.10
21.60
20.10
18.60
91.30
100.50
109.70
118.80
1.00
1.14
1.29
1.45
116BNA024****A
18.30
17.20
16.10
14.80
85.30
94.90
104.40
114.00
1.30
1.47
1.65
1.85
20.30
19.10
17.80
16.50
86.30
95.80
105.30
114.70
1.30
1.47
1.65
1.86
22.40
21.00
19.60
18.20
87.30
96.70
106.10
115.50
1.30
1.47
1.66
1.86
24.60
23.10
21.60
20.10
88.30
97.70
107.00
116.30
1.30
1.48
1.66
1.87
27.00
25.40
23.70
22.00
89.40
98.70
107.90
117.20
1.30
1.48
1.67
1.88
29.50
27.70
25.90
24.10
90.50
99.70
108.90
118.10
1.31
1.49
1.68
1.89
116BNA030****A
22.20
20.80
19.40
17.90
87.00
96.40
105.80
115.10
1.60
1.78
1.99
2.23
24.50
23.10
21.50
19.90
88.10
97.40
106.70
116.00
1.61
1.79
2.00
2.24
27.10
25.50
23.80
22.00
89.20
98.50
107.70
117.00
1.61
1.80
2.01
2.25
29.80
28.00
26.20
24.30
90.40
99.60
108.80
118.00
1.61
1.80
2.01
2.26
32.60
30.70
28.80
26.70
91.70
100.80
110.00
119.20
1.61
1.80
2.02
2.26
35.70
33.60
31.50
29.30
93.00
102.10
111.20
120.30
1.61
1.80
2.02
2.27

See notes on page 20

18

115 (46.11)

125 (51.67)

10.20
123.70
1.60
11.50
124.40
1.60
12.80
125.20
1.60
14.10
126.10
1.61
15.60
127.00
1.62
17.10
128.00
1.63

9.20
133.10
1.81
10.30
133.80
1.81
11.50
134.50
1.81
12.80
135.30
1.82
14.10
136.20
1.82
15.50
137.10
1.84

13.60
123.40
2.09
15.10
124.10
2.09
16.70
124.80
2.09
18.40
125.60
2.10
20.20
126.40
2.11
22.10
127.30
2.12

12.20
132.80
2.36
13.60
133.50
2.36
15.10
134.10
2.36
16.70
134.90
2.37
18.40
135.60
2.37
20.20
136.40
2.39

16.20
124.40
2.50
18.10
125.30
2.51
20.10
126.20
2.52
22.30
127.20
2.53
24.50
128.20
2.54
26.90
129.30
2.54

14.40
133.60
2.81
16.20
134.40
2.82
18.10
135.30
2.83
20.10
136.30
2.85
22.20
137.20
2.86
24.40
138.20
2.86

SST
° F (° C)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

55 (12.78)

65 (18.33)

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

31.50
68.90
1.50
34.80
70.10
1.50
38.30
71.40
1.51
42.10
72.80
1.52
46.20
74.40
1.53
50.50
76.00
1.55

29.90
78.20
1.73
33.00
79.30
1.73
36.40
80.60
1.74
40.00
81.90
1.75
43.90
83.30
1.77
47.90
84.90
1.79

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

37.90
69.80
1.83
41.90
71.20
1.84
46.10
72.70
1.85
50.70
74.20
1.86
55.50
75.80
1.87
60.70
77.40
1.89

36.20
79.20
2.03
40.00
80.60
2.04
44.00
81.90
2.05
48.30
83.30
2.07
52.90
84.80
2.09
57.70
86.40
2.11

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

42.80
67.80
2.00
47.40
69.00
1.93
52.30
70.40
1.82
57.80
71.80
1.68
63.70
73.20
1.49
70.10
74.70
1.25

40.60
77.20
2.29
44.80
78.30
2.25
49.50
79.60
2.18
54.60
80.80
2.07
60.10
82.20
1.93
66.00
83.70
1.74

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
116BNA036****A
28.30
26.60
24.80
22.90
87.50
96.80
106.20
115.50
1.96
2.21
2.50
2.82
31.20
29.40
27.40
25.40
88.60
97.90
107.20
116.50
1.97
2.22
2.51
2.83
34.40
32.40
30.30
28.10
89.80
99.00
108.20
117.40
1.98
2.24
2.52
2.85
37.80
35.60
33.30
30.90
91.00
100.20
109.40
118.50
1.99
2.25
2.54
2.86
41.50
39.00
36.50
33.90
92.40
101.50
110.50
119.60
2.01
2.27
2.56
2.88
45.30
42.70
39.90
37.10
93.80
102.80
111.80
120.80
2.04
2.30
2.58
2.91
116BNA042****A
34.30
32.30
30.10
27.90
88.70
98.10
107.40
116.70
2.26
2.54
2.86
3.22
37.90
35.70
33.30
30.80
89.90
99.20
108.40
117.70
2.28
2.56
2.88
3.24
41.70
39.20
36.70
34.00
91.20
100.40
109.60
118.70
2.30
2.58
2.90
3.26
45.80
43.10
40.20
37.30
92.50
101.60
110.80
119.80
2.32
2.60
2.92
3.29
50.10
47.10
44.00
40.80
93.90
103.00
112.00
121.00
2.34
2.63
2.95
3.32
54.60
51.30
47.90
44.40
95.40
104.40
113.40
122.30
2.36
2.66
2.99
3.36
116BNA048****B
38.30
36.00
33.60
31.10
86.60
96.00
105.40
114.70
2.58
2.87
3.17
3.51
42.30
39.70
37.10
34.40
87.70
97.00
106.30
115.60
2.56
2.87
3.19
3.53
46.60
43.80
40.90
37.90
88.80
98.00
107.20
116.50
2.52
2.85
3.19
3.55
51.40
48.20
45.00
41.70
90.00
99.10
108.30
117.40
2.45
2.81
3.17
3.55
56.50
52.90
49.40
45.70
91.30
100.30
109.40
118.50
2.34
2.74
3.13
3.53
62.00
58.00
54.10
50.00
92.60
101.60
110.60
119.60
2.20
2.63
3.06
3.49

See notes on page 20

19

115 (46.11)

125 (51.67)

21.00
124.90
3.21
23.30
125.80
3.21
25.80
126.70
3.22
28.40
127.70
3.24
31.20
128.70
3.25
34.20
129.80
3.28

18.90
134.20
3.66
21.10
135.00
3.66
23.40
135.90
3.66
25.80
136.80
3.67
28.40
137.70
3.68
31.10
138.70
3.70

25.50
125.90
3.63
28.30
126.80
3.65
31.20
127.80
3.67
34.30
128.90
3.70
37.50
130.00
3.73
40.80
131.20
3.77

23.00
135.10
4.09
25.60
136.00
4.10
28.30
136.90
4.13
31.10
137.90
4.15
34.10
138.90
4.19
37.10
140.00
4.22

28.50
124.00
3.90
31.60
124.80
3.92
34.90
125.70
3.94
38.30
126.60
3.95
42.00
127.50
3.95
45.90
128.50
3.94

25.80
133.30
4.35
28.60
134.10
4.36
31.60
134.80
4.38
34.80
135.70
4.40
38.10
136.50
4.41
41.60
137.40
4.41

116B

CONDENSER ONLY RATINGS CONTINUED

CONDENSER ONLY RATINGS CONTINUED
SST
° F (° C)
30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)

116B

55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

30
( --- 1.11)
35
(1.67)
40
(4.44)
45
(7.22)
50
(10.0)
55
(12.78)

55 (12.78)

65 (18.33)

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

45.00
70.30
2.04
49.80
71.70
1.99
54.90
73.20
1.93
60.40
74.80
1.86
66.20
76.40
1.78
72.40
78.20
1.68

42.40
79.50
2.41
46.80
80.90
2.39
51.50
82.40
2.36
56.60
83.90
2.33
62.00
85.50
2.28
67.70
87.10
2.23

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

49.90
70.90
2.31
55.30
72.50
2.31
61.00
74.10
2.31
67.20
75.80
2.31
73.70
77.60
2.31
80.80
79.50
2.31

47.50
80.40
2.60
52.60
81.80
2.61
58.00
83.40
2.63
63.80
84.90
2.64
70.00
86.60
2.65
76.60
88.40
2.66

TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW

47.40
70.70
1.95
52.30
72.20
1.98
57.60
73.90
2.01
63.20
75.60
2.05
69.20
77.40
2.09
75.60
79.30
2.14

46.30
80.00
2.35
51.10
81.40
2.38
56.20
82.90
2.41
61.70
84.50
2.45
67.50
86.20
2.50
73.70
88.00
2.56

CONDENSER ENTERING AIR TEMPERATURES ° F (° C)
75 (23.89)
85 (29.44)
95 (35.0)
105 (40.56)
116BNA049****A
39.90
37.40
34.90
32.30
88.90
98.20
107.60
116.90
2.75
3.08
3.44
3.84
44.00
41.20
38.50
35.60
90.10
99.40
108.70
118.00
2.75
3.10
3.47
3.87
48.40
45.30
42.20
39.10
91.50
100.70
109.90
119.00
2.75
3.12
3.50
3.91
53.00
49.60
46.20
42.80
92.90
102.00
111.10
120.20
2.75
3.14
3.53
3.95
58.00
54.20
50.50
46.70
94.50
103.40
112.40
121.40
2.73
3.15
3.56
3.99
63.20
59.10
55.00
50.90
96.10
104.90
113.80
122.60
2.71
3.16
3.59
4.02
116BNA060****A
45.10
42.40
39.60
36.70
89.80
99.20
108.50
117.80
2.90
3.24
3.61
4.05
49.80
46.90
43.90
40.70
91.20
100.50
109.70
118.90
2.93
3.27
3.65
4.08
54.90
51.70
48.40
45.00
92.60
101.80
111.00
120.10
2.95
3.29
3.68
4.12
60.30
56.90
53.30
49.60
94.10
103.20
112.30
121.40
2.97
3.32
3.71
4.15
66.20
62.40
58.50
54.50
95.70
104.70
113.70
122.70
2.99
3.35
3.75
4.19
72.40
68.30
64.00
59.80
97.30
106.20
115.20
124.00
3.02
3.39
3.79
4.24
116BNA061****A
45.00
43.40
41.50
39.30
89.20
98.50
107.70
116.90
2.79
3.30
3.90
4.61
49.60
47.90
45.90
43.40
90.60
99.70
108.90
118.00
2.82
3.34
3.94
4.65
54.60
52.70
50.40
47.80
92.00
101.00
110.10
119.10
2.86
3.38
3.99
4.70
59.90
57.80
55.30
52.40
93.50
102.50
111.40
120.40
2.91
3.43
4.04
4.75
65.50
63.20
60.40
57.20
95.10
104.00
112.80
121.70
2.96
3.49
4.10
4.82
71.40
68.80
65.70
62.20
96.80
105.60
114.30
123.00
3.03
3.56
4.17
4.89

* AHRI listing applies only to systems shown in Combination Ratings table.
KW --- Outdoor Unit Kilowatts Only.
SDT --- Saturated Temperature Leaving Compressor (° F)
SST --- Saturated Temperature Entering Compressor (° F/° C)
TCG --- Gross Cooling Capacity (1000 Btuh)

20

115 (46.11)

125 (51.67)

29.50
126.20
4.32
32.60
127.20
4.34
35.80
128.20
4.38
39.30
129.20
4.41
42.90
130.30
4.45
46.70
131.40
4.49

26.40
135.40
4.89
29.30
136.30
4.90
32.30
137.20
4.92
35.50
138.10
4.94
38.70
139.10
4.98
42.10
140.10
5.01

33.50
127.00
4.56
37.30
128.10
4.59
41.40
129.20
4.63
45.70
130.40
4.66
50.40
131.60
4.70
55.30
132.90
4.74

30.20
136.30
5.17
33.80
137.30
5.19
37.60
138.30
5.22
41.70
139.40
5.25
46.10
140.50
5.28
50.70
141.60
5.32

36.80
126.00
5.45
40.70
127.00
5.49
44.80
128.10
5.54
49.00
129.20
5.59
53.50
130.40
5.65
58.20
131.70
5.72

33.80
135.10
6.46
37.40
136.00
6.49
41.20
137.00
6.53
45.20
138.10
6.58
49.40
139.10
6.64
53.60
140.30
6.70

System Description
Outdoor--mounted, air--cooled, split--system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a
hermetic compressor, an air--cooled coil, propeller--type
condenser fan, and a control box. Unit will discharge supply air
upward as shown on contract drawings. Unit will be used in a
refrigeration circuit to match up to a packaged fan coil or coil
unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition
of AHRI Standard 210.
— Unit will be certified for capacity and efficiency, and
listed in the latest AHRI directory.
— Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have c--UL--us approval.
— Unit cabinet will be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061) 500--hr
salt spray test.
— Air--cooled condenser coils will be leak tested at 150
psig and pressure tested at 450 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is
stored and handled per unit manufacturer’s
recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and Canada only.

PRODUCTS
Equipment
Factory assembled, single piece, air--cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge Puronr (R--410A), and
special features required prior to field start--up.
Unit Cabinet
— Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.

AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
116B
1--1/2 TO 5 NOMINAL TONS
Fans
— Condenser fan will be direct--drive propeller type,
discharging air upward.
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compressor
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
Condenser Coil
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
Refrigeration Components
— Refrigeration circuit components will include
liquid--line shutoff valve with sweat connections,
vapor--line shutoff valve with sweat connections,
system charge of Puronr (R--410A) refrigerant, and
compressor oil.
— Unit will be equipped with filter drier for Puron
refrigerant.
Operating Characteristics
— The capacity of the unit will meet or exceed _____
Btuh at a suction temperature of _____ _F/_C. The
power consumption at full load will not exceed _____
kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering
air temperature at the evaporator at _____ _F/_C wet
bulb and _____ _F/_C dry bulb, and air entering the
unit at _____ _F/_C.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.

21

116B

GUIDE SPECIFICATIONS
GENERAL

SYSTEM DESIGN SUMMARY
1.
2.
3.
4.
5.
6.

7.

116B

8.
9.

Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01--in. wc.
Minimum outdoor operating air temperature for cooling mode without low--ambient operation accessory is 55_F (12.8_C).
Maximum outdoor operating air temperature is 125_F (51.7_C).
For reliable operation, unit should be level in all horizontal planes.
For interconnecting refrigerant tube lengths greater than 80 ft (23.4 m) and/or 35 ft (10.7 m) vertical differential, consult Residential
Piping and Longline Guideline and Service Manual available from equipment distributor.
If any refrigerant tubing is buried, provide a 6 in. (152.4 mm) vertical rise to the valve connections at the unit. Refrigerant tubing
lengths up to 36 in. (914.4 mm) may be buried without further consideration. Do not bury refrigerant lines longer than 36 in. (914.4
mm).
Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector
provided.
Do not apply capillary tube indoor coils to these units.
Factory--supplied filter drier must be installed.

Copyright 2012 Bryant Heating & Cooling Systems. S 7310 W. Morris St. S Indianapolis, IN 46231

Edition Date: 09/12

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

22

Catalog No: PDS116B---04
Replaces: PDS116B--- 03



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Format                          : application/pdf
Creator                         : bact04l
Title                           : PDS116B-04
Create Date                     : 2012:09:25 14:25:17-04:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2012:10:01 11:04:10-04:00
Metadata Date                   : 2012:10:01 11:04:10-04:00
Producer                        : Acrobat Distiller 8.3.1 (Windows)
Document ID                     : uuid:0caae800-896d-4ba0-a8ec-7128489db8ac
Instance ID                     : uuid:1e7f7467-d698-4ad7-8164-8674d86aa153
Page Count                      : 22
Author                          : bact04l
EXIF Metadata provided by EXIF.tools

Navigation menu