Bryant Induced Combustion 333Bav Users Manual

333BAV to the manual 8ca49f5c-ef96-441e-9838-f20643908d6f

2015-02-02

: Bryant Bryant-Induced-Combustion-333Bav-Users-Manual-411954 bryant-induced-combustion-333bav-users-manual-411954 bryant pdf

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadBryant Bryant-Induced-Combustion-333Bav-Users-Manual-  Bryant-induced-combustion-333bav-users-manual
Open PDF In BrowserView PDF
service and
maintenance procedures

333BAV
333JAV
Series B

UPFLOW/HORIZONTAL,
VARIABLE-SPEED, 2-STAGE,
INDUCED-COMBUSTION FURNACES
Cancels:

SP04-43

SP04-50
10-97

NOTE: Read the entire instruction manual before performing any
service or maintenance.
This symbol → indicates a change since the last issue.
These procedures are for size 60,000 through 120,000 Btuh units.
Index

Page

SAFETY CONSIDERATIONS .....................................................1
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE ...........................................................................2
CARE AND MAINTENANCE..................................................2-5
Air Filter Arrangement..........................................................2-3
Blower Motor and Wheel.........................................................3
Cleaning Heat Exchanger......................................................3-5
Electrical Controls and Wiring.................................................5
Troubleshooting ........................................................................5
Application Wiring Diagrams ..................................................6
Unit Wiring Diagram................................................................7
Service Label ............................................................................8
Troubleshooting Guide .............................................................9

A95137

Fig. 1—Model 333BAV or 333JAV Horizontal

®

SAFETY CONSIDERATIONS

ama

Installing and servicing heating equipment can be hazardous due to
gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions
such as cleaning and replacing air filters. All other operations must
be performed by trained service personnel. When working on
heating equipment, observe precautions in the literature, tags, and
labels attached to or shipped with the unit and other safety
precautions that may apply.

CANADIAN GAS ASSOCIATION

A PP R O VED
R

→ Follow

all safety codes. In the United States, follow all safety
codes including the National Fuel Gas Code NFPA No. 541996/ANSI Z223.1-1996. In Canada, refer to the current edition of
the National Standard of Canada CAN/CGA-B149.1- and .2-M95
Natural Gas and Propane Gas Installation Codes. Wear safety
glasses and work gloves. Have fire extinguisher available during
start-up and adjustment procedures and service calls.

A94085

CERTIFICATION OF
MANUFACTURING SITE

Fig. 2—Model 333BAV or
333JAV Upflow

Recognize safety information. This is the safety-alert symbol
.
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
WARNING: The ability to properly perform maintenance on this equipment requires certain expertise, mechanical skills, tools, and equipment. If you do not
possess these items, do not attempt to perform any
maintenance on this equipment other than those procedures recommended in the User’s Manual. A FAILURE
TO FOLLOW THIS WARNING COULD RESULT IN
POSSIBLE DAMAGE TO THIS EQUIPMENT, SERIOUS PERSONAL INJURY, OR DEATH.

Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage.

—1—

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE

WARNING: Turn off the gas and electrical supplies to
the unit before performing any maintenance or service on
it. Follow the operating instructions on the label attached
to the furnace. A failure to follow this warning could
result in personal injury.

CAUTION: Electrostatic discharge can affect electronic
components. Take precautions during furnace installation
and servicing to protect the furnace electronic control and
motor. Precautions will prevent electrostatic discharges
from personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing
the control to electrostatic discharge by putting the
furnace, the control, the motor, and the person at the same
electrostatic potential.

CAUTION: As with any mechanical equipment, personal injury can result from sharp metal edges, etc.;
therefore, be careful when removing parts.

The minimum maintenance that should be performed on this
equipment is as follows:
1. Check and clean air filter each month or more frequently if
required. Replace if torn.
2. Check blower motor and wheel for cleanliness each heating
and cooling season. Clean as necessary.
3. Check electrical connections for tightness and controls for
proper operation each heating season. Service as necessary.

1. Disconnect all power to the furnace. DO NOT TOUCH
THE CONTROLS OR ANY WIRE CONNECTED TO
THE CONTROLS PRIOR TO DISCHARGING YOUR
BODY’S ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the
furnace chassis which is close to the controls. Tools held in
a person’s hand during grounding will be satisfactorily
discharged.

CAUTION: If motor is removed from blower assembly,
the motor MUST be reinstalled so arrow on end of the
motor is pointing in the direction of airflow through the
furnace. The belly band MUST be the specified distance
from the motor end shield surface at the shaft end. (See
Fig. 3.)

3. After touching the chassis you may proceed to service the
controls, motor, or connecting wires as long as you do
nothing that recharges your body with static electricity (for
example; DO NOT move or shuffle your feet, DO NOT
touch ungrounded objects, etc.).
4. If you touch ungrounded objects (recharge your body with
static electricity), firmly touch furnace again before touching control or wires.

D

5. Use this procedure for installed and uninstalled (ungrounded) furnaces.
6. Before removing a new control or motor from its container,
discharge your body’s electrostatic charge to ground to
protect the control or motor from damage. If the control or
motor is to be installed in a furnace, follow items 1 through
5 before bringing the control, or motor, or yourself into
contact with the furnace. Put all used AND new controls
and motors into containers before touching ungrounded
objects.
7. An ESD service kit (available from commercial sources)
may also be used to prevent ESD damage.

A95268

CARE AND MAINTENANCE

DIMENSIONS (IN.)
FURNACE SIZE
036060
048080
060100
060120

For continuing high performance and to minimize possible equipment failure, it is essential that periodic maintenance be performed
on this equipment. Consult your local dealer as to the proper
frequency of maintenance and the availability of a maintenance
contract.

D
1
1-1/2
3
3

Fig. 3—Motor Belly Band Location
A. Air Filter Arrangement
The air filter arrangement may vary depending on the application.
Refer to Table 1 for filter size information.

WARNING: Never store anything on, near, or in contact
with the furnace, such as: 1. Spray or aerosol cans, rags,
brooms, dust mops, vacuum cleaners, or other cleaning
tools.
2. Soap powders, bleaches, waxes or other cleaning
compounds, plastic or plastic containers, gasoline, kerosene, cigarette lighter fluid, dry cleaning fluids, or other
volatile fluids.
3. Paint thinners and other painting compounds, paper
bags or other paper products.
A failure to follow this warning could result in corrosion
of the heat exchanger, fire, personal injury, or death.

WARNING: Never operate unit without a filter or with
filter access door removed. A failure to follow this
warning could result in fire, personal injury, or death.

1. Upflow and horizontal.
Each furnace requires 1 or 2 filters which are installed in the
blower compartment. (See Fig. 4.) To remove filters for
cleaning or replacement, proceed as follows:
—2—

TABLE 1—UPFLOW/HORIZONTAL FILTER SIZE INFORMATION (IN.)
FURNACE
CASING WIDTH
14-3/16
21
24-1/2

Clean as follows:
1. Remove blower access door.

FILTER SIZE†
FILTER
TYPE
Side Return
Bottom Return
(1) 16 X 25 X 1* (1) 14 X 25 X 1 Cleanable
(1) 16 X 25 X 1 (1) 20 X 25 X 1* Cleanable
(2) 16 X 25 X 1* (1) 24 X 25 X 1 Cleanable

2. Disconnect blower electrical leads from motor. Squeeze
latches to remove connectors from motor. Disconnect green
ground wire from screw. Note location of wires for reassembly.
3. Remove control.

* Factory-provided with the furnace.
† Filters may be field modified as required by cutting and folding the frame as
indicated on the filter.

4. Remove screws holding blower assembly to blower deck
and slide blower assembly out of furnace.

a. Turn off electrical supply before removing blower and
control access doors.

5. Mark blower wheel, motor, and motor support in relation to
blower housing before disassembly to ensure proper reassembly.

b. Release filter retainer from clip at front of furnace
casing. (See Fig. 4.) For side return, clips may be used
on either or both sides of the furnace.

6. Loosen setscrew(s) holding blower wheel on motor shaft.
7. Remove bolts holding motor and motor mount to blower
housing and slide motor and mount out of housing. Motor
mount belly band need not be removed unless motor is to be
replaced.

MOUNTING
SCREWS
DRAFT
SAFEGUARD
SWITCH

RELIEF
BOX
MAIN
LIMIT
SWITCH

CAUTION: The blower wheel should not be dropped or
bent as balance will be affected.

PRESSURE
SWITCHES

8. Remove blower wheel from housing.
a. Mark cutoff plate location to ensure proper reassembly.
b. Remove screws holding cutoff plate and remove cutoff
plate from housing.
c. Lift blower wheel from housing through opening.

MANUAL
RESET
LIMIT
SWITCHES

9. Clean blower wheel and motor using a vacuum with soft
brush attachment. Do not remove or disturb balance weights
(clips) on blower wheel blades.

AIRFLOW
SELECTOR

10. Reinstall blower wheel by reversing items 8 a through c. Be
sure wheel is positioned for proper rotation.

CONTROL

11. Reassemble motor and blower by reversing items 4 through
7.
WASHABLE
FILTER

CAUTION: Be sure the motor is properly positioned in
the blower housing. The motor arrow must point in the
direction of airflow through the furnace after the blower
assembly has been reinstalled in the furnace.

FILTER
RETAINER

12. Reinstall blower assembly in furnace.

A95270

13. Reinstall control. If motor has ground wire, be sure it is
connected as before.

Fig. 4—Upflow/Horizontal Component Identification
c. Slide filter out.

14. Connect blower electrical leads to motor. Please note that
connections are polarized for assembly. DO NOT FORCE.

d. Clean filters by spraying tap water through filter from
opposite direction of airflow.

15. If power choke is attached to blower housing, ensure it is
connected in series with black power lead to motor.

e. Rinse and let dry. Oiling or coating of filter is not
recommended or required.

C. Cleaning Heat Exchanger
The following steps should be performed by a qualified service
technician:
NOTE: Deposits of soot and carbon indicate the existence of a
problem which needs to be corrected. Take action to correct the
problem.
If it becomes necessary to clean the heat exchanger because of
carbon deposits, soot, etc., proceed as follows:

f. Place filter in furnace.
g. Replace blower and control access doors and turn on
electrical supply to furnace.
B. Blower Motor and Wheel
For long life, economy, and high efficiency, clean accumulated dirt
and grease from the blower wheel and motor annually.
The following steps should be performed by a qualified service
technician:
The motors have prelubricated sealed bearings and require no
lubrication.
Remember to disconnect the electrical supply before removing
access doors.

1. Turn gas and power to furnace to OFF.
2. Remove control and blower access doors.
3. Disconnect wires to the following components. Mark wires
to aid in reconnection of:
—3—

NOTE: Be very careful when removing the burner assembly to
avoid breaking the ignitor. See Fig. 6 for the correct ignitor
location.

a. Draft safeguard switch.
b. Inducer motor.
c. Pressure switch(es).

11 32"

13 32"

d. Limit overtemperature switch(es).
BURNER

e. Gas valve.
f. Hot surface ignitor.
g. Flame-sensing electrode.
h. Wiring connectors leading to control.

CELL
PANEL

4. Remove 2 screws that secure relief box. (See Fig. 4.)
5. Remove 8 screws that secure flue collector box to center
panel. Be careful not to damage sealant.

HOT
SURFACE
IGNITOR
ASSEMBLY

6. Remove complete inducer assembly from furnace, exposing
flue openings.
7. Using field-provided small wire brush, steel spring cable,
reversible electric drill, and vacuum cleaner, clean cells as
follows:
a. Assemble wire brush and steel spring cable.
(1.) Use 48 in. of 1/4-in. diameter high-grade steel
spring cable (commonly known as drain clean-out
or Roto-Rooter cable).
(2.) Use 1/4-in. diameter wire brush (commonly known
as 25-caliber rifle cleaning brush).
NOTE: The materials needed in items (1.) and (2.) can usually be
purchased at local hardware stores.

C
L
7 8"

IGNITOR

C
L

BURNER

IGNITOR
ASSEMBLY

(3.) Insert twisted wire end of brush into end of spring
cable, and crimp tight with crimping tool or strike
with ball-peen hammer. TIGHTNESS IS VERY
IMPORTANT.

Fig. 6—Position of Ignitor to Burner

A93347

(6.) IMPORTANT: Replace screws in center panel to
secure heat exchanger cells before cleaning.

(4.) Remove metal screw fitting from wire brush to
allow insertion into cable.
b. Clean each heat exchanger cell.

(7.) Insert brush end of cable in lower opening of cell,
and proceed to clean 2 lower passes of cell in same
manner as 2 upper passes.

(1.) Attach variable-speed, reversible drill to end of
spring cable (end opposite brush).

(8.) Repeat foregoing procedures until each cell in
furnace has been cleaned.

(2.) Remove cell outlet plates. IMPORTANT: Replace
screws in center panel to secure heat exchanger
cells before cleaning.

(9.) Using vacuum cleaner, remove residue from each
cell.

(3.) Insert brush end of cable into upper opening of cell
and slowly rotate with drill. DO NOT force cable.
Gradually insert at least 36 in. of cable into 2 upper
passes of cell. (See Fig. 5.)

(10.) Using vacuum cleaner with soft brush attachment,
clean burner assembly.
(11.) Reinstall cell outlet plates and screws FIRST;
then, reinstall cell inlet plates and burner assembly. Care must be exercised to center the burners
in the cell openings.
8. After cleaning flue openings, clean flue collector. Check
sealant on flue collector to ensure that it has not been
damaged. If new sealant is needed, contact your dealer or
distributor.
9. Replace flue collector assembly, making sure all 8 screws
are secure.
10. Reinstall relief box.
11. Reconnect wires to the following components:
a. Draft safeguard switch.

A91252

b. Inducer motor.

Fig. 5—Cleaning Heat Exchanger Cell

c. Pressure switches.

(4.) Work cable in and out of cell 3 or 4 times to obtain
sufficient cleaning. DO NOT pull cable with great
force. Reverse drill and gradually work cable out.

d. Limit overtemperature switch(es).
e. Gas valve.
f. Hot surface ignitor.

(5.) Remove burner assembly and cell inlet plates.
—4—

g. Flame-sensing electrode.

The control in this furnace is equipped with an LED status light to
aid in installation, servicing, and troubleshooting. It can be viewed
through the sight glass or window on the blower access door. The
control indicates status with the LED on continuously, rapid
flashing, or a code composed of 2 digits. (The first digit is the
number of short flashes, the second is the number of longs flashes.)
Refer to the service label on the blower compartment door for code
explanations and useful troubleshooting suggestions. (See Fig. 10.)

h. Wiring connectors leading to control.
12. Reconnect vent pipe to relief box.
13. Replace blower door only.
14. Turn power and gas to ON.
15. Set thermostat and check furnace for proper operation.
16. Verify blower airflow and that airflow rate changes between
heating and cooling.

It is important to note that power to the furnace must not be
interrupted and the furnace blower door must not be removed until
the LED status code(es) is recorded. When power to the control is
interrupted, the status memory is erased.

17. Check for gas leaks.
18. Replace control door.

The control will store up to 5 previous codes but will not store
non-current codes longer than 48 hr. To retrieve previous codes, if
present, no thermostat inputs to the control must be present and all
time delays must expire. Remove 1 of the red main limit wires 1
to 4 sec until the LED light goes out, then reconnect it. (See Fig.
4.) (Do not leave red wire disconnected for longer than 4 sec as the
control will assume an overtemperature condition exits and will
respond with indoor blower operation.) This places the control in
the status recall mode and displays the first code stored in memory.
Record the code and repeat the disconnect and reconnect of the red
wire, recording each code until code 11 is displayed indicating no
additional faults. After the last code is displayed or after 2 minutes
in the code recall mode, the control will return to normal standby
mode.

WARNING: Never use a match or other open flame to
check for gas leaks. Use a soap-and-water solution. A
failure to follow this warning could result in fire, personal
injury, or death.

D. Electrical Controls and Wiring
NOTE: There may be more than 1 electrical supply to unit.
The electrical ground and polarity for 115-v wiring must be
maintained properly. Refer to Fig. 7 and 8 for field wiring
information and to Fig. 9 for unit wiring information. If the
polarity is NOT correct, the furnace control will display rapid
flashing on the status LED and prevent heat operation. The control
system also requires an earth ground for proper operation of the
microprocessor and variable-speed motor.
NOTE: Be aware that measurement of current (amperes) and
power (watts) for the ICM2+ variable-speed motor will be accurate
only when the meter provides true root-mean-square (RMS)
measurements.
With power disconnected from unit, check all electrical connections for tightness. Tighten all screws on electrical connections. If
any smoky or burned connections are noticed, disassemble the
connection, clean all parts and stripped wire, and reassemble
properly and securely. Electrical controls are difficult to check
without proper instrumentation; therefore, reconnect electrical
power to unit and observe unit through 1 complete operating cycle.
The 24-v circuit contains an automotive-type, 3-amp fuse located
on the main control. Any 24-v electrical shorts during installation,
service, or maintenance could cause this fuse to blow. If fuse
replacement is required, use ONLY a 3-amp fuse. The control will
display code 24 when the fuse needs replacement.

Use any recorded status codes, the service label, and the troubleshooting diagram on the following pages to diagnose and correct
any problem condition.
E.

Troubleshooting

Refer to the service label. (See Fig. 10.) Page 9 contains a
troubleshooting guide. This guide can be a useful tool in isolating
furnace operation problems. Beginning with the word "Start,"
answer each question and follow the appropriate arrow to the next
item.
The guide will help to identify the problem or failed component.
After replacing any component, verify correct operation sequence.
More information is available in a separate Troubleshooting Guide
for 2-stage gas-fired induced-combustion furnaces.

—5—

FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
NOTE 2
W

FIVE
WIRE

C

Y

R

G

1-STAGE
THERMOSTAT
TERMINALS

FIELD-SUPPLIED
FUSED DISCONNECT

THREE-WIRE
HEATINGONLY
BLK

BLK

WHT

WHT

208/230- OR
460-V
THREE
PHASE

W2
COM

208/230-V
SINGLE
PHASE

W/W1

GND

NOTE 1

Y/Y2

115-V FIELDSUPPLIED
FUSED
DISCONNECT

JUNCTION
BOX
CONTROL
BOX

R

GND

CONDENSING
UNIT

G

NOTE 4
24-V
Y1
NOTES: 1. Connect Y/Y2-terminal as shown for proper operation.
TERMINAL
2. Some thermostats require a "C" terminal connection as shown.
BLOCK
3. If any of the original wire, as supplied, must be replaced, use
FURNACE
same type or equivalent wire.
4. Y1 is not to be connected.
NOTE 5
5. Connect O to thermostat-O only for heat pump applications.
O

AFS

A97588

→ Fig. 7—Heating and Cooling Application Wiring Diagram
for Single-Stage Thermostats and/or Single-Speed Condensing Units
FIELD 24-V WIRING
FIELD 115-, 208/230-, 460-V WIRING
FACTORY 24-V WIRING
FACTORY 115-V WIRING
NOTE 2
C

W2

W1

Y2

R

SEVEN
WIRE
FOUR-WIRE
HEATINGONLY
BLK

BLK

WHT

WHT

G

Y1

2-STAGE
THERMOSTAT
TERMINALS

FIELD-SUPPLIED
FUSED DISCONNECT
208/230- OR
460-V
THREE
PHASE

W2
COM

208/230-V
SINGLE
PHASE

W/W1

GND

Y/Y2

115-V FIELD- JUNCTION
SUPPLIED
BOX
FUSED
CONTROL
DISCONNECT
BOX
AFS

NOTE 1

C
Y1
Y2

R

24-V
TERMINAL
BLOCK
FURNACE

Y1

NOTE 4
O

GND

2-SPEED
CONDENSING
UNIT

G

NOTES: 1. Connect Y1 and Y/Y2 as shown for proper operation.
2. Some thermostats require a "C" terminal connection as shown.
3. If any of the original wire, as supplied, must be replaced, use
same type or equivalent wire.
4. Connect O to thermostat-O only for heat pump applications.
A97589

→ Fig. 8—Heating and Cooling Application Wiring Diagram
for 2-Stage Thermostats and/or 2-Speed Condensing Units

—6—

—7—

YEL

N/A
PL1
PL2

RED

315
COOL
CFM
PER
TON
BLU

350

400

BLK

GAS
HEAT
TEMP
RISE
RED

HI

M-HI

MID

RED

LO

MED

HI

GRN

BLU

1

-

GRN

CONTINUOUS FAN
CFM

D

C

O

BLK

Y1

ORN

WHT
BLK

NOTE 4

ORN

AC
HP

CMFT

HP

EFFY

HP

AC

BLU
GRN

BLU

B

BLK

A

YEL

LEGEND

AIRFLOW SELECTOR
AUXILIARY LIMIT SWITCH, OVERTEMP. MANUAL RESET, SPST (N.C.)
AUXILIARY LIMIT SWITCH, OVERTEMP. AUTO RESET, SPST (N.C.)
BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLOWER MOTOR SPEED CHANGE RELAY, SPDT
BLOWER MOTOR, ICM2+ -CTL = CONTROL
-PWR = POWER
BLOWER MOTOR RELAY, SPST (N.O.)
MICROPROCESSOR AND CIRCUITRY
DRAFT SAFEGUARD SWITCH (N.C.)
ELECTRONIC AIR CLEANER CONNECTION (115 VAC, 1 AMP MAX.)
ELECTRONIC AIR CLEANER CONNECTION (COMMON)
FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FLAME ROLLOUT SWITCH OVERTEMP. MANUAL RESET, SPST (N.C.)
FLAME-PROVING SENSOR ELECTRODE
FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE, FACTORY INSTALLED
FUSE, FIELD INSTALLED
GAS VALVE, REDUNDANT LOW-HEAT OPERATORS, 2-STAGE
HIGH-HEAT PRESSURE SWITCH, SPST (N.O.)
HIGH-HEAT PRESSURE SWITCH RELAY, SPST (N.C.)
HOT-SURFACE IGNITER (115 VAC)
HOT-SURFACE IGNITOR RELAY, SPST (N.O.)
24VAC HUMIDIFIER CONNECTION (0.5 AMP. MAX.)
INDUCED DRAFT MOTOR, 2-SPEED, SHADED-POLE
INDUCER MOTOR RELAY, SPST (N.O.)
INDUCER MOTOR SPEED CHANGE RELAY, SPDT
BLOWER DOOR INTERLOCK SWITCH, SPST (N.O.)
INDUCTOR (NOTE 16)
JUNCTION BOX
LIGHT-EMITTING DIODE FOR STATUS CODES
LOW GAS-PRESSURE SWITCH, SPST (N.O.)
LOW-HEAT PRESSURE SWITCH, SPST (N.O.)
LIMIT SWITCH, OVERTEMPERATURE-AUTO RESET, SPST (N.C.)
MAIN GAS VALVE RELAY DPST (N.O.)
-1 = VALVE
-2 = HUMIDIFIER
NOT APPLICABLE
12-CIRCUIT CONNECTOR
9-CIRCUIT CONNECTOR

AFS

YEL

COOL

LO

M-LO

HI
M-HI

PL7

AFS
ALS1
ALS2
BHI / LOR
BHT / CLR
BLWM
BLWR
CPU
DSS
EAC-1
EAC-2
FRS1
FRS2
FSE
FU1
FU2
GV
HPS
HPSR
HSI
HSIR
HUM
IDM
IDR
IHI / LOR
ILK
IND
JB
LED
LGPS
LPS
LS
MGVR

ORN

14

RED

PL3
PL4
PL5
PL6
PL7
PL8
PL9
SW1
SW2
SW3 & 4

TRAN
TWIN/TEST

TJ

SWITCH
1
2

BLOWEROFF DELAY SWITCH
(SEC.)
3
4
90 SEC
135 SEC
180 SEC
225 SEC

*

*

RED

R

G

LED

TWIN
TEST

RED

S

M

TJ

RED

ORN

YEL

BLU

BLK

BRN

RED

PL4

YEL

2-STAGE
FURNACE
CONTROL

HUM

ALS1

AIRFLOW SELECTOR FACTORY SETTING

AIRFLOW SELECTOR JUMPER PINS

PLUG RECEPTACLE

FIELD SPLICE

EQUIPMENT GROUND

FIELD GROUND

FIELD WIRING SCREW TERMINAL

CONDUCTOR ON CONTROL

FIELD CONTROL WIRING (24VAC)

FIELD POWER WIRING (115VAC)

FACTORY CONTROL WIRING (24VAC)

FACTORY POWER WIRING (115VAC)

CONTROL TERMINAL

TERMINAL

JUNCTION

3-CIRCUIT IDM CONNECTOR
6-CIRCUIT CONNECTOR
1-CIRCUIT CONNECTOR (NOTE 16)
2-CIRCUIT HSI CONNECTOR
14-CIRCUIT CONNECTOR
5-CIRCUIT CONNECTOR
16-CIRCUIT CONNECTOR
HIGH-HEAT-ONLY SWITCH, SPST (MANUAL)*
LOW-HAT-ONLY SWITCH, SPST (MANUAL)*
BLOWER-OFF DELAY SETTING SWITCHES,
SPST (MANUAL)*
TWINNING JUMPER,
SPDT(MANUAL CHANGE-OVER). (NOTE 17)
TRANSFORMER-115VAC/24VAC
1-CIRCUIT TWINNING BUSS CONNECTOR,
ALSO STATUS CODE RECALL. (NOTE 17)

Com W/W1 Y/Y2
24V

WHT

WHT

ALS2

DSS

(WHEN USED)
NOTE 7

BLOWER-OFF DELAY
BLOWER-OFF DELAY
LOW-HEAT ONLY
HIGH-HEAT ONLY

SETTINGS

GRN

W2

RED

* FACTORY

ORN
ORN
ORN
ORN

LGPS

(WHEN USED)

YEL
NOTE 9
YEL

FSE
WHT
GRN

BLK
BRN

L2

EAC-2

COMMON

BLU

FU1

2

RED

WHT

3

1

9

PL8

PL9

YEL

5
4
3
2
1

PL3

NOTE 15

2

WHT

GRN

PL5 BLK

IND
WHT
N
GR

PL5

BLK

RED

1

IDM

GRN

L2

JB
L1

BLU

BRN

WHT

BLK

GRN

ILK

HPS
GV

COMPONENT TEST

C
GRN

BLWM

GRN

WHT

→ Fig. 9—Unit Wiring Diagram

TRAN

16

Y1

O

Y1

DELAY

COOL

O

6

4

5

9

14

11

Y/Y2

15

2

G

3

C2

W/W1

HEAT

1

7

12

R
C1

ADJ

13

EM/W2

8

10

+
OUT OUT

PL9

L1

FU1

IDR

HSIR

IHI / LOR

7

4

3

1

11

5

6

8

9

14

C OM

DE

M
HU

G

Y/Y2

W2

SW1

2

COOL
SIZE

LO

M-LO

M-HI

HI

LO-GAS-HEAT

CPU

BLWR

BHT / CLR

AC
HP

CMFT

HP

EFFY

HP

AC

GAS
HEAT
TEMP
RISE

HI

M-HI

MID

MGVR-1

PL4

HI-COOL
COMMON

BHI / LOR

SEC2

PR2

SPARE

HI-GAS-HEAT

315
COOL
CFM
PER
TON

350

400

MGVR-2

24VAC

TRAN

115VAC

EAC-1 EAC-2

BHT / CLR

BHI / LOR

Y2

HI

A

3

6

2

1

4

5

12

B

-

13

PL1

NOTE 4

CONTINUOUS FAN
CFM

LO

MED

10

C1

G

Y

W2

PL2

C

LO

8

2

ALS1

C
NOTE 8

M

NOTE 9

D

11 N/A

FSE

HI

AFS

GV

P

HPS

LPS
(WHEN USED)
LGPS

NOTE 9 DSS

L2

322293-101 REV. C

A97587

PL7

LS
ALS2
(WHEN USED)

FRS1

7
8 N/A

10

1

4

5

6

9

3

2

12 N/A

FRS2 (WHEN
USED)

3 COM

HI

HSI

7

1
2

2
1

PL6

BLWM-PWR

4 PL3

9

3

5
4
3
2
1

1
5 N/A
6 N/A

PL8

SEE BLWM-CTL
PL5

HPSR

IND
NOTE 15

PL5

24
VAC

TO 115VAC FIELD DISCONNECT SWITCH

TWIN
TEST
SLAVE
TWINNING
JUMPER
TJ
W/W1 MASTER
NOTE
16

R

HUM

SEC1

BLWR

PR1

NOTE 1
ILK

NOTE 6

EQUIPMENT
GROUND

BK/PWM

BLWM-CTL

8

16

FU2

FUSED DISCONNECT
SWITCH (WHEN REQ’D)
NOTE #1
BLK

M

HI
P

Use only copper wire between the disconnect switch and the furnace.
If any of the original wire, must be replaced, use the same or equivalent type.
Inducer (IDM) motor contains internal auto-reset thermal overload switch.
Blower motor airflow selections are for nominal conditions. See Installation
Instructions for details on optimum airflow selections.
Blower motor (BLWM) is locked-rotor overload protected by redundant
electronic control circuits. Restart is attempted every 15 seconds for 2 minutes,
after which it locks OFF. Reset by turning OFF all control and/or power inputs.
Replace only with a 3-AMP fuse.
Auxiliary limit switches (ALS1 & 2) used on some horizontal and some
downflow models.
This wire must be connected to furnace sheet metal for control to prove flame.
Factory connected when LGPS not used.
Symbols are an electrical representation only.
BLOWER-ON DELAY: Gas heating 45 seconds, Cooling/Heat Pump 2 sec.
Cooling/Heat Pump BLOWER-OFF DELAY is 90 seconds.
IGNITION-LOCKOUT will occur after four consecutive unsuccessful
trials-for-ignition. Control will automatically reset after three hours.
Control must be grounded at pin 10 of 12-pin connector.
Inductor is used on 060 or -20 cooling airflow size furnaces only.
PL5 connectors are joined without IND on other furnace sizes.
Twinning is not permitted with ICM2+ blower motors. Keep twinning jumper in
MASTER position.
Terminals (HI-COOL, HI-GAS-HEAT, and LO-GAS-HEAT) are not used for
ICM2+ BLWM. Do not remove electrical insulators.

SEC2

SEC1

SPARE SPARE

LO-GAS
HEAT EAC-1

HI-COOL
HI-GAS
HEAT

PL1

PR2

PL2

1

PL6

HSI

BRN

GRY

BLK

To initiate the component test sequence with no thermostat inputs and
with all inducer Post-Purge and Blower-Off Delay periods completed,
short the "TWIN/TEST" terminal to the "COM" terminal for about two
seconds. The control will turn ON the inducer motor Low-Speed, inducer
motor High-Speed, HSI, blower motor Continuous-Fan Speed, blower
motor High-Gas-Heat Speed, and blower motor High-Cool Speed for
7-15 seconds each. Neither the gas valve nor the humidifier will be
turned ON.

17.

16.

14.
15.

8.
9.
10.
11.
12.
13.

6.
7.

5.

1.
2.
3.
4.

L1

PR1

NOTE 17

NOTES:

WHT

RED
HEAT
SET-UP
SWITCH
NORM
HI HT
LO HT

DEHUM

VIO

YEL

ON
OFF
ON
OFF

RED
BLK

FRS1
(WHEN USED)

1 2 3 4

6

ON
OFF
ON
OFF
ON
OFF

BLK
2
3
GRY
12 11 10

1
BLU
1
2
3

GRY
1

8 7
9

WHT

Connect VIO wire to pin
A, B, C, or D as
designated on furnace
rating plate as "PIN".

SIZE

WHT

NOTE 9

BLK

LPS

BRN

BLK ORN
WHT GRN
BLK VIO
RED

WHT
RED

FRS2

SCHEMATIC DIAGRAM (NATURAL GAS & PROPANE)

RED

YEL
YEL

BLU
GRN

BLK
BLU

NOTE 17

LS

IDM

CONNECTION DIAGRAM

SW4
SW3
SW2

BLU

WARNING
Service should be performed only by qualified persons.

SERVICE
If status code recall is needed, do not remove power or blower door.

LED CODE

STATUS

CONTINUOUS OFF Check for 115V at L1 and L2, and 24V at SEC1 and SEC2.
CONTINUOUS ON Control has 24V power.
RAPID FLASHING Line voltage polarity reversed. If twinned, 24V power
to one furnace may be out of phase with power to other furnace.
EACH OF THE FOLLOWING STATUS CODES IS A TWO-DIGIT NUMBER WITH
THE FIRST DIGIT DETERMINED BY THE NUMBER OF SHORT FLASHES AND
THE SECOND DIGIT BY THE NUMBER OF LONG FLASHES.
11
12
13
14
21
22
23
24
31
32

33

34

43

45

NO PREVIOUS CODE - Stored status codes are erased when power (115V or
24V) to control is interrupted or 48 hours after each fault is cleared.
BLOWER ON AFTER POWER UP - Blower runs for 90 seconds, if unit is
powered up during a call for heat (R-W/W1 closed). Note: 2-sec. ON-delay.
LIMIT OR FLAME ROLL-OUT (FRS) SWITCH LOCKOUT - Auto-reset after
three hours. FRS switch requires manual-reset.
Check for: - Refer to #33
IGNITION LOCKOUT - Control will auto-reset after three hours. Refer to #34.
GAS HEATING LOCKOUT - Control will NOT auto-reset.
Check for: - Mis-wired gas valve
- Defective control (valve relay)
ABNORMAL FLAME-PROVING SIGNAL - Flame is proved while gas valve is
de-energized. Inducer will run until fault is cleared.
Check for: - Leaky gas valve
- Stuck-open gas valve
LOW- OR HIGH-HEAT PRESSURE SWITCH DID NOT OPEN
Check for: - Obstructed pressure tubing
- Defective pressure switch (stuck closed)
SECONDARY VOLTAGE FUSE IS OPEN
Check for: - Short-circuit in secondary voltage (24V) wiring
HIGH-HEAT PRESSURE SWITCH OR RELAY DID NOT CLOSE OR
REOPENED
Check for: -Control relay may be defective - Refer to #32
LOW-HEAT PRESSURE, DRAFT SAFEGUARD , OR AUX-LIMIT
(DOWNFLOW ONLY*) SWITCH DID NOT CLOSE OR REOPENED
Check for: - Proper vent sizing (and condensate pitch with side-wall vent)
- Low inducer voltage (115v)
* Blower motor and capacitor
- Defective inducer motor
- Defective pressure switch
- Excessive wind
- Restricted vent
- Inadequate combustion air supply
- Disconnected or obstructed pressure tubing
LIMIT OR FLAME ROLL-OUT (FRS) SWITCH IS OPEN - FRS switch
requires manual-reset.
Check for: - Inadequate combustion air supply (FRS switch only)
- Dirty filter or restricted duct system
- Loose blower wheel
- Defective switch or connections
- Blower motor or capacitor failure
IGNITION-PROVING FAULT - Control will retry three times before lockout #14.
Check for: - Oxide buildup on flame-proving sensor (clean with fine sandpaper).
- Proper flame-proving microamps (0.5 minimum)
- Proper control ground continuity
- Flame-proving sensor must be ungrounded
- Smooth flame carryover and ignition
- Manual valve(s) OFF
LOW-HEAT PRESSURE, DRAFT SAFEGUARD, OR AUXILIARY LIMIT
SWITCH OPEN WHILE HIGH-HEAT PRESSURE SWITCH IS CLOSED
Check for: - Disconnected or obstructed pressure tubing
- Defective pressure switch (stuck open)
- Refer to #32 and #33
REPLACE CONTROL
320893-101 REV. A
A94169

Fig. 10—Service Label

—8—

NOTES:
1. Refer to information label on blower compartment door
for procedure for use of LED status codes and problem
solving suggestions.
2. LED indicator is viewed through window in blower
compartment door.
3. If 115-vac power is de-energized or interrupted during
a call for heat, the indoor blower will run for 90 sec
before a gas heating cycle begins – Code 12.
4. After replacing any component, verify correct operating
sequence.

TROUBLESHOOTING
GUIDE

! WARNING
ELECTRICAL SHOCK HAZARD
ONLY QUALIFIED AND TRAINED
SERVICE PERSONNEL SHOULD
PERFORM THIS PROCEDURE

If LED is flashing rapidly, check line voltage polarity.
If Code 24 is displayed, check for blown fuse.
If LED is OFF, check line voltage and 24-v transformer.

START

If Code 45 is displayed, replace control.

Turn thermostat OFF.

Is indoor blower on ?

On furnace control, note current
settings for setup switches 1 (SW-1)
and 2 (SW-2) then set SW-1 to OFF
and SW-2 to ON.

Yes

No
24v should be present across C and W. If not, check for:
1. Open thermostat.
2. Open 24-v fuse (FU1) – Code 24.
3. Failed transformer.
If Code 23 is displayed, the pressure switch(es) is stuck closed.
Replace switch and/or check pressure tube for blockage.

Cycle 115-v power
off for 3 sec, then on.

No
No

System malfunction – Code 21.
No
Continuous LED?

24v should be present across R
and C. If not, check for:
1. Open flame rollout switch
(FRS) – Code 33.
2. Open limit switch (LS) –
Code 33.
3. Check all low-voltage wiring
connections.

Replace control only if all checks
are OK.

115v should be present at the inducer motor. If so, replace inducer
motor. If not, check 115-v wiring.

Yes
Set thermostat to call for heat.
Set FAN to AUTO.

No
Draft inducer motor starts.

If Code 32 is displayed check for:
1. Open gas inlet pressure switch (when used).
2. Open pressure switch (LPS) and/or tube – Code 32.
3. Open draft safeguard switch (DSS) – Code 32.
4. Open auxiliary switch (ALS)(downflow only) – Code 32.
5. Check all low-voltage wiring connections.

No

Replace control only if Code 45 is
displayed, or if all checks are OK.

No

Replace control only if Code 45 is
displayed, or if all checks are OK.

115v should be present at the ignitor. If so, replace the ignitor; if not,
check 115-vac wiring to ignitor.

Yes
No
Is Code 22 displayed?
Yes

LPS, DSS, or ALS open while HPS is closed (high-gas-heat only) –
Code 43.
Control will attempt to light burners 4 times (approximately 1 minute
between attempts – Code 34). Voltage is present at the gas valve for 7
sec during each ignition trial. System will lockout after 4 attempts.

Flame present when not normal.
Replace gas valve.

Is the gas valve control knob in the OPEN or ON position?
24v should be present across the gas valve terminals C and M/P
(and C and HI for high-stage test) during the 7 sec ignition trial. If
not, check all low-voltage wiring connections to valve.

15-sec inducer pre-purge.
Yes
Ignitor warms up and glows
orange/yellow; 17-sec warm-up.

No

Yes
No
Main burners ignite.

If 24v are present, and main gas does not flow:
1. Is supply pressure between 4.5- and 13.6-in. wc? If not,
adjust supply pressure.
2. If supply pressure is between 4.5- and 13.6-in. wc, replace
gas valve.
Check ignitor position.
Check burner carryover gap.
Check manifold pressure (1.3- to 1.7-in. wc for low-stage gas
heat; 3.2- to 3.8-in. wc for high-stage gas heat).

Yes

Check for proper orifice size.

No
Main burners stay on.
Yes

Is Code 31 (high-gas-heat only), 32, 33, or 34 displayed? Check
code information label to diagnose.
Check polarity of 115-v power at J-box and control – Rapid
flashing LED.

No

Check ground continuity from J-box to control.

Replace control if Code 45 is displayed, or if all checks are OK.
Clean flame sensor if microamps
are below nominal.

Check flame sensor microamps (4.0 nominal; 0.5 minimum for
control to recognize flame).
Indoor blower motor starts on
heating speed after 45-sec
warm-up period.

No
See 2-Stage Gas-Fired Induced-Combustion Furnaces
Troubleshooting Guide (PSC and ICM Blower Motors).

Yes

Furnace runs until call for
heat ends.

No

Yes
Turn thermostat to OFF; gas valve
shuts off burners; 5-sec inducer
post purge.

No

Yes
Heating sequence of operation
complete. Remove blower door,
move setup switch 1 (SW-1) to ON
position and repeat process to check
high-stage gas heat operation.
(When finished return SW-1 and
SW-2 to original desired settings.)

No

Replace control only if Code 45 is
displayed, or if all checks are OK.

No

Replace control only if Code 45 is
displayed, or if all checks are OK.

No

Replace control only if Code 45 is
displayed, or if all checks are OK.

Check for sources of electrical noise interference (electronic air
cleaners, nearby TV, or radio antennas).

Yes
Indoor blower motor stops after
90, 135, 180, or 225 sec.

If not, check for:
1. Satisfied thermostat.
2. Open inlet gas pressure switch (when used).
3. Open pressure switch (LPS) – Code 32.
4. Open draft safeguard switch (DSS) – Code 32.
5. Open auxiliary limit (ALS)(downflow only) – Code 32.
6. Open 24-v fuse (FU1) – Code 24.
7. Open limit switch (LS) – Code 13 or 33.
8. Open flame rollout switch (FRS) – Code 13 or 33.
9. Check 115-v line voltage – LED off.

No

If inducer and burners continue to operate, check for 24v at the
gas valve. If 24v are present, verify that the thermostat is open
across R and W. If no voltage is present, turn the gas valve
control knob to the OFF position. Replace gas valve.
24v should be present across R and C. If not, check for:
1. Open limit switch (LS) – Code 13 or 33.
2. Open flame rollout switch (FRS) – Code 13 or 33.
24v should not be present across R and G. If so, turn thermostat
FAN switch to AUTO.

A96062

—9—

—10—

—11—

SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
• Unit Familiarization
• Maintenance
• Installation Overview
• Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training

[ ] Classroom Service Training
A94328

© 1997 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231

—12—

Printed in U.S.A.

sp0450

Catalog No. 5333-301



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Create Date                     : 1997:11:03 08:34:13Z
Modify Date                     : 2005:11:14 11:53:31-05:00
Metadata Date                   : 2005:11:14 11:53:31-05:00
Producer                        : Acrobat Distiller 2.0 for Windows
Keywords                        : 
Format                          : application/pdf
Title                           : 
Description                     : 
Creator                         : Carrier Corporation
Subject                         : 
Document ID                     : uuid:11b8e4d8-5fbb-41d9-b53a-2aed5ddc048d
Instance ID                     : uuid:e6df9ff6-944c-4073-a5bf-6d6134aeb2a6
Page Count                      : 12
Author                          : Carrier Corporation
EXIF Metadata provided by EXIF.tools

Navigation menu