Bryant Legacy 580J Users Manual
580J to the manual 0e3081b5-8240-478b-a75c-010ffa90a7d9
2015-02-02
: Bryant Bryant-Legacy-580J-Users-Manual-411739 bryant-legacy-580j-users-manual-411739 bryant pdf
Open the PDF directly: View PDF .
Page Count: 94
Download | |
Open PDF In Browser | View PDF |
580J GAS HEAT/ELECTRIC COOLING PACKAGED ROOFTOP 3 TO 15 NOMINAL TONS Product Data C08515 (Unit shown with optional louvered hail guard.) the environmentally sound refrigerant 580J TABLE OF CONTENTS PAGE PAGE FEATURES AND BENEFITS . . . . . . . . . . . . . . . . . . . . 3 COOLING TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . 4 STATIC PRESSURE ADDERS . . . . . . . . . . . . . . . . . . 53 FACTORY OPTIONS AND/OR ACCESSORIES . . . . . 6 FAN PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . 56 AHRI COOLING RATING TABLES . . . . . . . . . . . . . . . 8 ELECTRICAL INFORMATION . . . . . . . . . . . . . . . . . 69 HEAT RATING TABLE . . . . . . . . . . . . . . . . . . . . . . . . . 9 MCA / MOCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 SOUND PERFORMANCE TABLE . . . . . . . . . . . . . . . 10 TYPICAL WIRING DIAGRAMS . . . . . . . . . . . . . . . . 77 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . 81 CURBS & WEIGHTS DIMENSIONS . . . . . . . . . . . . . 18 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . 84 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . . . . 30 Your Bryant rooftop unit (RTU) was designed by customers for customers. With “no-- strip screw” collars, handled access panels, and more we’ve made your unit easy to install, easy to maintain and easy to use. Easy to install: All Legacy Liner units are field-- convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Bryant 3-- 15 ton 580J rooftops fit on existing Bryant curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Bryant accessory controls. Easy to maintain: Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our “no-- strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Easy to use: The newly designed, central terminal board by Bryant puts all your connections and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Bryant rooftops have high and low pressure switches, a filter drier, and 2-- in (51mm) filters standard. the environmentally sound refrigerant 2 FEATURES AND BENEFITS S Single cooling stage models are available from 3 - 10 ton. S Two cooling stage models are available from 7.5 - 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 - 12.5 ton units fit on existing Bryant rooftop curbs. This saves time and money on replacement jobs. S Standardized components and layout. Standardized components and controls make service and stocking parts easier. S Field convertible airflow (3 - 15 ton). Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. 15 ton models require a simple supply duct cover to field convert from factory vertical to horizontal. S Easy-- adjust, belt-- drive motor available. Bryant provides a factory solution for most points in the fan performance table. S Provisions for bottom or side condensate drain. S Capable of thru-- the-- base or thru-- the-- curb gas line routing. S Single-- point gas / electrical connection. S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust. S Standardized controls & control box layout. Standardized components & controls make stocking parts & service easier. S Tool-- less filter access door. S Clean, easy to use control box. S Color-- coded wiring. S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. S Single, central terminal board for test and wiring connections. S Fast-- access, handled, panels for easy access on normally accessed service panels. S “No-- strip” screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, or the unit. S Exclusive, newly-- design indoor refrigerant header for easier maintenance and replacement. S Mechanical cooling (115_F to 40_F or 46_C to 4_C) standard on all models. Winter Start Kit allows cooling operation down to 25_F (-- 4_C) and Motor Master to - 20_F (-- 29_C). S High efficiency, gas heat with induced-- draft flue exhaust design (3 - 15 tons). S Induce draft motor ensures no flue gas can escape into the indoor air stream. S Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense. S 2-- in (51mm) disposable filters on all units. S Refrigerant filter-- drier on each circuit. S Each circuit is protected with a high and low pressure switch. S Many factory-- installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switch and smoke detectors. S Standard Parts Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr. parts. S Factory-- installed Perfect Humidity system on 3 - 12.5 ton models, includes MotorMaster I controller. 3 580J S Scroll compressors on all units. This makes service, stocking parts, replacement, and troubleshooting easier. MODEL NUMBER NOMENCLATURE 1 2 3 4 5 8 0 J E 0 ____________ 5 6 7 8 9 6 A 0 ______ 10 11 12 13 14 15 16 17 7 2 A 1 A 0 A A ________ ______ Unit Type Packaging 580J = Cooling/Gas Heat RTU A = Standard Legacy Series w/Puron Refrigerant B = LTL Voltage Factory Installed Options E = 460--- 3--- 60 0A = None J = 208/230--- 1--- 60 P = 208/230--- 3--- 60 Intake/Exhaust Options T = 575--- 3--- 60 A = None 580J B = Temp econo w/ baro relief Cooling Tons E = Temp econo w/ baro relief & CO2 04 = 3 Ton H = Enthalpy econo w/ baro relief 05 = 4 Ton L = Enthalpy econo w/ baro relief & CO2 06 = 5 Ton Q = Motorized 2 pos damper 07 = 6 Ton 08 = 7.5 Ton Indoor Fan Options 09 = 8.5 Ton 1 = Standard static option 12 = 10 Ton 2 = Medium static option 14 = 12.5 Ton 3 = High static option 16 = 15 Ton C = High Static Option w/High Efficiency Motor (Size 16 only) Refrig. System/Gas Heat Options Coil Options A = Standard 1--- Stage Cooling models/Nat gas heat Models w/Round Tube Plate Fin (RTPF) condenser coil B = Standard 1--- Stage Cooling models/Low NOx heat (Outdoor --- Indoor --- Hail Guard) C = Standard 1--- Stage Cooling models/SS Gas HX A = Al/Cu --- Al/Cu D = 2--- Stage Cooling models 08--- 16 B = Precoat Al/Cu --- Al/Cu F = 2--- Stage Cooling models and SS Gas HX (08--- 16) C = E--- coat Al/Cu --- Al/Cu G = 1--- Stage Cooling/Al HX w/Perfect Humidity 04--- 07 D = E--- coat Al/Cu --- E--- coat Al/Cu H = 1--- Stage Cooling/Low Nox Heat w/Perfect Humidity 04--- 07 E = Cu/Cu --- Al/Cu J = 1--- Stage Cooling/SS Gas HX w/Perfect Humidity 04--- 07 F = Cu/Cu --- Cu/Cu K = 2--- Stage Cooling/Al Gas HX w/Perfect Humidity 08-14 M = Al/Cu --- Al/Cu --- Louvered Hail guards M = 2--- Stage Cool/SS Gas HX w/Perfect Humidity 08-14 N = Precoat Al/Cu --- Al/Cu --- Louvered Hail Guards P = E coat Al/Cu --- Al/Cu --- Louvered Hail Guards Heat Level Input Q = E coat Al/Cu --- E coat Al/Cu --- Louvered Hail Guards Standard/Stainless Steel R = Cu/Cu --- Al/Cu --- Louvered Hail Guards 072 = 72,000 S = Cu/Cu --- Cu/Cu --- Louvered Hail Guards 115 = 115,000 Models w/All aluminum, Novation condenser coils 125 = 125,000 (Outdoor --- Indoor --- Hail Guard) 150 = 150,000 G = Al/Al --- Al/ Cu 180 = 180,000 H = Al/Al --- Cu/Cu 224 = 224,000 J = Al/Al --- E coat Al/Cu 240 = 240,000 K = E coat Al/Al --- Al/ Cu 250 = 250,000 L = E coat Al/Al --- E coat Al/Cu 350 = 350,000 T = Al/Al --- Al/Cu --- Louvered Hail Guards Low NOx U = Al/Al --- Cu/ Cu, Louvered Hail Guards 060 = 60,000 V = Al/Al --- E coat Al/Cu, Louvered Hail Guards 090 = 90,000 W = E coat Al/Al --- Al/ Cu, Louvered Hail Guards 120 = 120,000 X = E coat Al/Al --- E coat Al/Cu, Louvered Hail Guards 4 Table 1 – FACTORY-- INSTALLED OPTIONS AND FIELD-- INSTALLED ACCESSORIES Cabinet Coil Options Humidity Control Condenser Protection Controls Economizers & Outdoor Air Dampers Economizer Sensors & IAQ Devices Gas Heat Indoor Motor & Drive Low Ambient Control Power Options Roof Curbs ITEM Thru ---the ---base electrical or gas---line connections Supply Duct Cover Cu/Cu indoor and/or outdoor coils1 Pre ---coated outdoor coils1 Premium, E ---coated outdoor coils1 Perfect Humidity System (3 --- 12.5 ton) Condenser coil hail guard (louvered design) Thermostats, temperature sensors, and subbases RTU Open ---protocol controller Smoke detector (supply and/or return air) Time Guard II compressor delay control circuit Phase Monitor EconoMi$ert IV (for electro---mechanical controlled RTUs) EconoMi$ert2 (for DDC controlled RTUs) Motorized 2 position outdoor air damper Manual outdoor air damper (25% and 50%) Barometric relief2 Power exhaust Single dry bulb temperature sensors3 Differential dry bulb temperature sensors3 Single enthalpy sensors3 Differential enthalpy sensors3 Wall or duct mounted CO2 sensor3 Unit mounted CO2 sensor3 Propane conversion kit Stainless steel heat exchanger High altitude conversion kit Flue Shield Flue Discharge Deflector Multiple motor and drive packages Winter start kit4 Motormaster head pressure controller4 Convenience outlet (powered) Convenience outlet (un ---powered) Non ---fused disconnect5 Disconnect Switch Bracket Roof curb 14---in (356mm) Roof curb 24---in (610mm) NOTES: 1. Novation coated coils only available with E ---coat. 2. Included with economizer. 3. Sensors used to optimize economizer performance. 4. See application data for assistance. 5. Available on units with MOCP’s of 80 amps or less. 5 FACTORY INSTALLED OPTION X X X X X X FIELD INSTALLED ACCESSORY X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 580J CATEGORY FACTORY OPTIONS AND/OR ACCESSORIES Economizer (dry--bulb or enthalpy) Power Exhaust with Barometric Relief Economizers save money. They bring in fresh, outside air for ventilation; and provide cool, outside air to cool your building. This is the preferred method of low ambient cooling. When coupled to CO2 sensors, economizers can provide even more savings by coupling the ventilation air to only that amount required. Superior internal building pressure control. This field installed accessory may eliminate the need for costly, external pressure control fans. 580J Economizers are available, installed and tested by the factory, with either enthalpy or dry-- bulb temperature inputs. There are also models for electromechanical as well as direct digital controllers. Additional sensors are available as accessories to optimize the economizers. Economizers include gravity controlled, barometric relief which equalizes building pressure and ambient air pressures. This can be a cost effective solution to prevent building pressurization. CO2 Sensor Improves productivity and saves money by working with the economizer to intake only the correct amount of outside air for ventilation. As occupants fill your building, the CO2 sensor detects their presence through increasing CO2 levels, and opens the economizer appropriately. When the occupants leave, the CO2 levels decrease, and the sensor appropriately closes the economizer. This intelligent control of the ventilation air, called Demand Control Ventilation (DCV) reduces the overall load on the rooftop, saving money. Smoke Detectors Trust the experts. Smoke detectors make your application safer and your job easier. Bryant smoke detectors immediately shut down the rooftop unit when smoke is detected. They are available, installed by the factory, for supply air, return air, or both. Louvered Hail Guards Sleek, louvered panels protect the condenser coil from hail damage, foreign objects, and incidental contact. Convenience Outlet (powered or un--powered) Reduce service and/or installation costs by including a convenience outlet in your specification. Bryant will install this service feature at our factory. Provides a convenient, 15 amp, 115v GFCI receptacle with “Wet in Use” cover. The “powered” option allows the installer to power the outlet from the line side of the disconnect or load side as required by code. The “un-- powered” option is to be powered from a separate 115/120v power source. RTU Open, Multi--Protocol Controller Connect the rooftop to an existing BAS without needing complicated translators or adapter modules using the RTU Open controller. This new controller speaks the 4 most common building automation system languages (Bacnet, Modbus, N2, and Lonworks). Use this controller when you have an existing BAS. Time Guard II Control Circuit This accessory protects your compressor by preventing short-- cycling in the event of some other failure, prevents the compressor from restarting for 30 seconds after stopping. Not required with RTU Open, or authorized commercial thermostats. Motorized 2--Position Damper The new Bryant 2-- position, motorized outdoor air damper admits up to 100% outside air. Using reliable, gear-- driven technology, the 2-- position damper opens to allow ventilation air and closes when the rooftop stops, stopping unwanted infiltration. Manual OA Damper Manual outdoor air dampers are an economical way to bring in ventilation air. The dampers are available in 25% and 50% versions. Optional Perfect Humidity System Bryant’s Perfect Humidity system is an all-- inclusive factory installed option that can be ordered with any Legacy Line 580J-- 04-- 14 rooftop unit. This system expands the envelope of operation of Bryant’s Legacy Line rooftop products to provide unprecedented flexibility to meet year round comfort conditions. The Perfect Humidity system has the industry’s only dual dehumidification mode setting. The Perfect Humidity system includes two new modes of operation. Non--fused Disconnect This OSHA-- compliant, factory installed, safety switch allows a service technician to locally secure power to the rooftop. 6 FACTORY OPTIONS AND/OR ACCESSORIES (cont.) Subcooling mode will operate to satisfy part load type conditions when the space requires combined sensible and a higher proportion of latent load control. Hot Gas Reheat mode will operate when outdoor temperatures diminish and the need for latent capacity is required for sole humidity control. Hot Gas Reheat mode will provide neutral air for maximum dehumidification operation. Motormaster Head Pressure Controller The Motormaster motor controller is a low ambient, head pressure controller kit that is designed to maintain the unit’s condenser head pressure during periods of low ambient cooling operation. This device should be used as an alternative to economizer free cooling when economizer usage is either not appropriate or desired. The Motormaster will either cycle the outdoor fan motors or operate them at reduced speed to maintain the unit operation, depending on the model. Winter Start Kit The winter start kit by Bryant extends the low ambient limit of your rooftop to 25_F (-- 4_C). The kit bypasses the low pressure switch, preventing nuisance tripping of the low pressure switch. Other low ambient precautions may still be prudent. Propane Heating Convert your gas heat rooftop from standard natural gas operation to propane using this field installed kit. High Altitude Heating High altitudes have less oxygen, which means heat exchangers need less fuel. The new gas orifices in this field installed kit make the necessary adjustment for high altitude applications. They restore the optimal fuel to air mixture and maintain healthy combustion at altitudes above 2000 ft (610m). Kits may not be required in all areas. Flue Discharge Deflector The flue discharge deflector is a useful accessory when flue gas recirculation is a concern. By venting the flue discharge upwards, the deflector minimizes the chance for a neighboring unit to intake the flue exhaust. Optional Stainless Steel Heat Exchanger The stainless steel heat exchanger option provides the tubular heat exchanger be made out of a minimum 20 gauge type 409 stainless steel for applications where the mixed air to the heat exchanger is expected to drop below 45_F (7_C). Stainless steel may be specified on applications where the presence of airborne contaminants require its use (applications such as paper mills) or in areas with very high outdoor humidity that may result in severe condensation in the heat exchanger during cooling operation. Flue Discharge Heat Shield The flue discharge heat shield keeps people from touching the rooftop unit’s potentially hot flue discharge. This is especially useful for ground level applications, where more, untrained people could have access to the unit’s exterior. Alternate Motors and Drives Some applications need larger horsepower motors, some need more airflow, and some need both. Regardless of the case, your Bryant expert has a factory installed combination to meet your application. A wide selection of motors and pulleys (drives) are available, factory installed, to handle nearly any application. Thru--the--Base Connections Thru-- the-- base connections, available as either an accessory or as a factory option, are necessary to ensure proper connection and seal when routing wire and piping through the rooftop’s basepan and curb. These couplings eliminate roof penetration and should be considered for gas lines, main power lines, as well as control power. Disconnect Switch Bracket Provides a pre-- engineered and sized mounting bracket for applications requiring a unit mounted fused disconnect of greater than 100 amps. Bracket assures that no damage will occur to coils when mounting with screws and other fasteners. Supply Duct Cover This supply duct cover is required when field converting the factory standard vertical duct supply to horizontal duct supply configuration. One required per unit. (16 size only) 7 580J The Legacy Line 580J-- 04-- 14 rooftop coupled with the Perfect Humidity system is capable of operating in normal design cooling mode, subcooling mode, and hot gas reheat mode. Normal design cooling mode is when the unit will operate under its normal sequence of operation by cycling compressors to maintain comfort conditions. 580J Table 2 – AHRI COOLING RATING TABLE Unit Cooling Stages Nom. Capacity (tons) Net Cooling Capacity (MBH) Total Power (KW) SEER EER IEER A04 A05 A06 A07 A08 D08 A09 D09 A12 D12 D14 D16 1 1 1 1 1 2 1 2 1 2 2 2 3 4 5 6 7.5 7.5 8.5 8.5 10 10 12.5 15 34.6 45.0 59.0 70.0 88.0 83.0 97.0 99.0 117.0 114.0 140.0 174.0 3.1 4.0 5.5 6.4 8.0 7.5 8.8 9.0 10.6 10.3 12.9 16.1 13.0 13.0 13.0 N/A N/A N/A N/A N/A N/A N/A N/A N/A 11.00 11.00 10.75 11.00 11.00 11.00 11.00 11.00 11.00 11.10 10.80 10.80 N/A N/A N/A 11.2 11.2 11.7 11.2 11.7 11.2 11.8 11.0 11.7 LEGEND AHRI --- Air Conditioning, Heating and Refrigeration Institute Test Standard ASHRAE --- American Society of Heating, Refrigerating and Air Conditioning, Inc. EER --- Energy Efficiency Ratio IEER --- Integrated Energy Efficiency Ratio SEER --- Seasonal Energy Efficiency Ratio NOTES: 1. Rated in accordance with AHRI Standard 210/240 or 340/360, as appropriate. 2. Ratings are based on: Cooling Standard: 80_F (27_C) db, 67_F (19_C) wb indoor air temp and 95_F (35_C) db outdoor air temp. IEER Standard: A measure that expresses cooling part---load EER efficiency for commercial unitary air conditioning and heat pump equipment on the basis of weighted operation at various load capacities. 3. All 580J units comply with ASHRAE 90.1 Energy Standard for minimum SEER and EER requirements. 4. 580J units comply with US Energy Policy Act (2005). To evaluate code compliance requirements, refer to state and local codes or visit the following website: http://bcap ---energy.org. Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. 8 AL/SS HEAT EXCHANGER Units Single Phase 04 05 06 04 05 06 Three Phase 07 08 09 12 14 16 Gas Heat LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH INPUT / OUTPUT STAGE 1 (MBH) --------------------82 / 66 ------120 / 96 ----120 / 96 ----120 / 96 --120 / 98 180 / 147 --120 / 98 180 / 147 120 / 98 180 / 147 200 / 160 120 / 98 180 / 147 200 / 160 144 / 118 192 / 156 280 / 224 INPUT / OUTPUT STAGE 2 (MBH) 72 / 59 115 / 93 --72 / 59 115 / 93 150 / 120 72 / 59 115 / 93 150 / 120 72 / 59 115 / 93 --72 / 59 115 / 93 150 / 120 72 / 59 115 / 93 150 / 120 72 / 59 115 / 93 150 / 120 125 / 103 180 / 148 224 / 184 125 / 103 180 / 148 224 / 184 180 / 148 224 / 184 250 / 205 180 / 148 224 / 184 250 / 205 180 / 146 240 / 195 350 / 280 TEMP RISE (DEG F) THERMAL EFFICIENCY (%) AFUE (%) 25 --- 55 55 --- 85 --25 --- 55 35 --- 65 50 --- 80 20 --- 55 30 --- 65 40 --- 80 25 --- 55 55 --- 85 --25 --- 55 35 --- 65 50 --- 80 20 --- 55 30 --- 65 40 --- 80 15 --- 55 25 --- 65 35 --- 80 20 --- 50 35 --- 65 45 --- 75 20 --- 50 30 --- 65 40 --- 75 25 --- 65 30 --- 65 35 --- 70 20 --- 65 25 --- 65 25 --- 70 15 --- 55 20 --- 60 35 --- 65 82% 80% --82% 81% 80% 82% 81% 80% 82% 80% --82% 81% 80% 82% 81% 80% 82% 81% 80% 82% 82% 82% 82% 82% 82% 82% 82% 80% 82% 82% 80% 81% 81% 80% 81% 80% --81% 80% 80% 81% 80% 80% N/A N/A --N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NOTES: Heat ratings are for natural gas heat exchangers operated at or below 2000 ft (610 m). For information on propane or altitudes above 2000 ft (610 m), see the Application Data section of this book. Accessory Propane/High Altitude kits are also available. In the USA the input rating for altitudes above 2000 ft (610m) must be derated by 4% for each 1000 ft (305 m) above sea level. In Canada, the input rating must be derated by 10% for altitudes of 2000 ft (610 m) to 4500 ft (1372 m) above sea level. 9 580J Table 3 – HEATING RATING TABLE - NATURAL GAS & PROPANE Table 4 – HEATING RATING TABLE - LOW NOx1 LOW NOx HEAT EXCHANGER UNIT GAS HEAT LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH Single Phase 04 05 06 Three Phase 580J 04 05 06 INPUT / OUTPUT STAGE 1 (MBH) ------------------------------------- INPUT / OUTPUT STAGE 2 (MBH) 60 / 50 90 / 74 --60 / 50 90 / 74 120 / 101 60 / 50 90 / 74 120 / 101 60 / 50 90 / 74 --60 / 50 90 / 74 120 / 101 60 / 50 90 / 74 120 / 101 TEMP RISE (DEG F) THERMAL EFFICIENCY (%) AFUE (%) 20 --- 50 30 --- 60 --20 --- 50 30 --- 60 40 --- 70 15 --- 50 25 --- 60 35 --- 70 20 --- 50 30 --- 60 --20 --- 50 30 --- 60 40 --- 70 15 --- 50 25 --- 60 35 --- 70 81% 81% --81% 81% 81% 81% 80% 80% 81% 81% --81% 81% 81% 81% 80% 80% 80% 81% --80% 81% 80% 80% 81% 81% N/A N/A --N/A N/A N/A N/A N/A N/A NOTE: 1. Units meet California’s South Coast Air Quality Management District (SCAQMD) Low ---NOx emissions requirement of 40 nanograms per joule or less. Table 5 – SOUND PERFORMANCE TABLE UNIT COOLING STAGES 04A 05A 06A 07A 08A 08D 09A 09D 12A 12D 14D 16D 1 1 1 1 1 2 1 2 1 2 2 2 LEGEND dB --- Decibel A ---WEIGHTED 80 81 78 78 82 82 83 82 82 82 87 87 63 90.6 90.9 84.0 88.8 90.1 85.8 91.2 88.6 88.6 89.0 87.0 87.0 125 80.9 84.6 82.2 81.8 82.6 84.3 86.4 85.0 85.0 83.1 85.2 85.2 OUTDOOR SOUND (dB) 250 500 1000 80.2 76 74.6 79.5 77.9 76.5 76.3 74.8 72.5 76.9 74.4 73.3 81.0 79.4 77.0 80.5 78.7 76.4 81.9 81.0 78.3 81.6 79.5 77.4 81.6 79.5 77.4 80.5 78.5 75.5 84.6 84.9 82.2 84.6 84.9 82.2 2000 71.3 71.1 68.8 69.8 73.0 72.7 73.9 74.1 74.1 71.6 78.4 78.4 4000 68.5 66.9 65.6 66.3 70.4 68.3 71.4 71.0 71.0 69.6 75.3 75.3 8000 63.9 62.5 61.8 62.7 66.7 65.1 67.3 66.3 66.3 69.3 72.9 72.9 NOTES: 1. Outdoor sound data is measure in accordance with AHRI standard 270---2008. 2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure depends on specific environmental factors which normally do not match individual applications. Sound power values are independent of the environment and therefore more accurate. 3. A ---weighted sound ratings filter out very high and very low frequencies, to better approximate the response of “average” human ear. A ---weighted measurements for Bryant units are taken in accordance with AHRI standard 270---2008. 10 Table 6 – MINIMUM - MAXIMUM AIRFLOW RATINGS - NATURAL GAS & PROPANE 580J**04 580J**05 580J**06 580J**07 580J**08 580J**09 580J**12 580J**14 580J**16 HEAT LEVEL LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH LOW MED HIGH COOLING HEATING MINIMUM MAXIMUM 900 1500 1200 2000 1500 2500 1800 3000 2250 3750 2550 4250 3000 5000 3600 6000 4500 7500 11 MINIMUM 990 1000 --990 1330 1390 990 1330 1390 990 1330 1390 1900 2100 2270 1900 2100 2270 2100 2620 2650 2100 2620 2650 2450 3000 3990 MAXIMUM 2190 1550 --2190 2460 2220 2730 2880 2780 3640 3450 3170 4750 3900 3780 4750 4560 4250 5470 5670 5290 6830 6800 7410 7500 6750 7200 580J UNIT 580J*05A 580J*06A 580J*07A 1 / 1 / Scroll 5--- 10 8--- 11 Acutrol 630 / 505 54 / 117 100% 1 / 1 / Scroll 8--- 8 14--- 13 Acutrol 630 / 505 54 / 117 100% 1 / 1 / Scroll 10--- 11 16--- 0 Acutrol 630 / 505 54 / 117 100% 1 / 1 / Scroll 14--- 2 22--- 5 Acutrol 630 / 505 54 / 117 100% Cu / Al 3/8--- in RTPF 2 / 15 5.5 3/4--- in Cu / Al 3/8--- in RTPF 2 / 15 5.5 3/4--- in Cu / Al 3/8--- in RTPF 4 / 15 5.5 3/4--- in Cu / Al 3/8--- in RTPF 4 / 15 7.3 3/4--- in Standard Static 1 phase Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 1.2 560--- 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560--- 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770--- 1175 48 1 / Centrifugal 10 x 10 ------------- Medium Static 1 phase Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 1.2 770--- 1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770--- 1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.5 1035--- 1466 56 1 / Centrifugal 10 x 10 ------------- Standard Static 3 phase Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 1.2 560--- 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 560--- 854 48 1 / Centrifugal 10 x 10 1 / Belt 1.5 770--- 1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1073--- 1457 56 1 / Centrifugal 10 x 10 Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 1.2 770--- 1175 48 1 / Centrifugal 10 x 10 1 / Belt 1.2 770--- 1175 48 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035--- 1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.9* 1173--- 1518 56 1 / Centrifugal 10 x 10 Motor Qty / Drive Type Max BHP RPM Range Motor Frame Size Fan Qty / Type Fan Diameter (in) 1 / Belt 2.4 1035--- 1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.4 1035--- 1466 56 1 / Centrifugal 10 x 10 1 / Belt 2.9 1303--- 1687 56 1 / Centrifugal 10 x 10 1 / Belt 3.7 1474--- 1788 56 1 / Centrifugal 10 x 10 Material (Tube/Fin) Coil type Rows / FPI Total Face Area (ft2) Cu / Al 3/8--- in RTPF 1 / 17 14.6 Cu / Al 3/8--- in RTPF 2 / 17 16.5 Cu / Al 3/8--- in RTPF 2 / 17 16.5 Cu / Al 3/8--- in RTPF 2 / 17 21.3 Material (Tube/Fin) Rows..Fins/in. Total Face Area (ft2) Cu / Al 1 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 3.9 Cu / Al 2 / 17 5.2 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 1/ Direct 1/4 / 1100 22 2 / 16 x 25 x 2 1 / 20 x 24 x 1 2 / 16 x 25 x 2 1 / 20 x 24 x 1 2 / 16 x 25 x 2 1 / 20 x 24 x 1 4 / 16 x 16 x 2 1 / 20 x 24 x 1 Refrigeration System # Circuits / # Comp. / Type Puronr refrig. (R--- 410A) (lbs--- oz) Operating charge (lbs--- oz) --- Perfect Humidity Unit Metering Device High--- press. Trip / Reset (psig) Low--- press. Trip / Reset (psig) Compressor Capacity Staging (%) Evap. Coil Material (Tube/Fin) Coil type Rows / FPI Total Face Area (ft2) Condensate Drain Conn. Size Evap. Fan and Motor 580J 3 - 6 TONS 580J*04A Medium Static 3 phase (COOLING) High Static 3 phase Table 7 – PHYSICAL DATA Cond. Coil Perfect Humidity Coil Cond. fan / motor Filters Qty / Motor Drive Type Motor HP / RPM Fan diameter (in) RA Filter # / Size (in) OA inlet screen # / Size (in) NOTE: Perfect Humidity is not available with Novation condenser coil models. Only Round Tube / Plate Fin (RTPF). * 575V motor utilizes 3.7 BHP. 12 580J**06 580J**07 1 4 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 1 4 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 1 4 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 1 4 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 0.14 0.14 0.14 0.14 0.14 0.14 0.14 0.14 LOW # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/2 1/2” NPT 195 / 115 25 --- 55 1/2 1/2” NPT 195 / 115 25 --- 55 1/2 1/2” NPT 195 / 115 20 --- 55 1/2 1/2” NPT 195 / 115 15 --- 55 MED # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1 or 2 / 3 1/2” NPT 195 / 115 55 --- 85 1/3 1/2” NPT 195 / 115 35 --- 65 1/3 1/2” NPT 195 / 115 30 --- 65 1/3 1/2” NPT 195 / 115 25 --- 65 HIGH # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise --------- 1 or 2 / 3 1/2” NPT 195 / 115 50 --- 80 1 or 2 / 3 1/2” NPT 195 / 115 40 --- 80 2/3 1/2” NPT 195 / 115 35 --- 80 Liquid Propane Heat # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/2 1/2” NPT 195 / 115 25 --- 55 1/2 1/2” NPT 195 / 115 25 --- 55 1/2 1/2” NPT 195 / 115 20 --- 55 1/2 1/2” NPT 195 / 115 15 --- 55 MED # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1 or 2 / 3 1/2” NPT 195 / 115 55 --- 85 1/3 1/2” NPT 195 / 115 35 --- 65 1/3 1/2” NPT 195 / 115 30 --- 65 1/3 1/2” NPT 195 / 115 25 --- 65 HIGH # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise --------- 1 or 2 / 3 1/2” NPT 195 / 115 50 --- 80 1 or 2 / 3 1/2” NPT 195 / 115 40 --- 80 2/3 1/2” NPT 195 / 115 35 --- 80 LOW 3 - 6 TONS 580J**05 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/2 1/2” NPT 195 / 115 20 --- 50 1/2 1/2” NPT 195 / 115 20 --- 50 1/2 1/2” NPT 195 / 115 15 --- 50 --------- MED (HEATING) 580J**04 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/3 1/2” NPT 195 / 115 30 --- 60 1/3 1/2” NPT 195 / 115 30 --- 60 1/3 1/2” NPT 195 / 115 25 --- 60 HIGH Table 8 – PHYSICAL DATA # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise --------- 1/3 1/2” NPT 195 / 115 40 --- 70 1/3 1/2” NPT 195 / 115 35 --- 70 ------------------- Gas Connection # of Gas Valves Nat. gas supply line press (in. w.g.) / (PSIG) LP supply line press (in. w.g.) / (PSIG) Heat Anticipator setting (Amps) 1st stage 2nd stage LOW Low NOx Gas Heat 13 580J Natural Gas Heat Table 9 – PHYSICAL DATA (COOLING) 7.5 - 8.5 TONS 580J*08A 580J*08D 580J*09A 580J*09D 1 / 1 / Scroll 13 --- 12/------Accutrol 630 / 505 54 / 117 --- 2 / 2 / Scroll 8 --- 5 / 8 --- 2 4 --- 6 / 4 --- 6 13 --- 3 / 13 --- 3 Accutrol 630 / 505 54 / 117 --- 1 / 1 / Scroll 15 --- 4/------Accutrol 630 / 505 54 / 117 --- 2 / 2 / Scroll 10 --- 5 / 10 --- 12 --16 --- 13 / 16 --- 13 Accutrol 630 / 505 54 / 117 --- Cu / Al 3/8” RTPF 3 / 15 8.9 3/4” Cu / Al 3/8” RTPF 3 / 15 8.9 3/4” Cu / Al 3/8” RTPF 3 / 15 11.1 3/4” Cu / Al 3/8” RTPF 3 / 15 11.1 3/4” --------- Cu / Al 3/8” RTPF 2 / 17 6.3 --------- Cu / Al 3/8” RTPF 2 / 17 8.4 1 / Belt 1.7 489--- 747 56 1 / Centrifugal 15 x 15 1 / Belt 2.9 733--- 949 56 1 / Centrifugal 15 x 15 1 / Belt 4.7 909--- 1102 14 1 / Centrifugal 15 x 15 1 / Belt 1.7 489--- 747 56 1 / Centrifugal 15 x 15 1 / Belt 2.9 733--- 949 56 1 / Centrifugal 15 x 15 1 / Belt 4.7 909--- 1102 14 1 / Centrifugal 15 x 15 1 / Belt 1.7 518--- 733 56 1 / Centrifugal 15 x 15 1 / Belt 2.4 690--- 936 56 1 / Centrifugal 15 x 15 1 / Belt 3.7 838--- 1084 56 1 / Centrifugal 15 x 15 1 / Belt 1.7 518--- 733 56 1 / Centrifugal 15 x 15 1 / Belt 2.4 690--- 936 56 1 / Centrifugal 15 x 15 1 / Belt 3.7 838--- 1084 56 1 / Centrifugal 15 x 15 Cu / Al 3/8” RTPF 2 / 17 20.5 Cu / Al 3/8” RTPF 2 / 17 20.5 Cu / Al 3/8” RTPF 2 / 17 21.4 --------- Al / Al Novation™ 1 / 20 20.5 --------- Cu / Al 3/8” RTPF 2 / 17 25.1 ----------- 2 / direct 1/4 / 1100 22 2 / direct 1/4 / 1100 22 2 / direct 1/4 / 1100 22 2 / direct 1/4 / 1100 22 RA Filter # / Size (in) 4 / 16 x 20 x 2 4 / 16 x 20 x 2 4 / 20 x 20 x 2 4 / 20 x 20 x 2 OA inlet screen # / Size (in) 1 / 20 x 24 x 1 1 / 20 x 24 x 1 1 / 20 x 24 x 1 1 / 20 x 24 x 1 Medium Static 3 phase Standard Static 3 phase # Circuits / # Comp. / Type RTPF models R--- 410a charge A/B (lbs --- oz) Alternate (MCHX) R--- 410a charge A/B (lbs --- oz) Alternate (Perfect Humidity) R--- 410a charge A/B (lbs --- oz) Metering device High--- press. Trip / Reset (psig) Low--- press. Trip / Reset (psig) Loss of charge Trip / Reset (psig) Evap. Coil Material Coil type Rows / FPI total face area (ft2) Condensate drain conn. size Perfect Humidity Coil Material Coil type Rows / FPI total face area (ft2) Evap. fan and motor Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Cond. Coil Material Coil type Rows / FPI total face area (ft2) Alternate (MCHX) Cond. Coil Material Coil type Rows / FPI total face area (ft2) Cond. fan / motor Qty / Motor drive type Motor HP / RPM Fan diameter (in) Filters High Static 3 phase 580J Refrigeration System NOTE: Perfect Humidity is not available with Novation condenser coil models. Only Round Tube/Plate Fin (RTPF). 14 Gas Connection (HEATING) 580J**09 1 4 --- 13 / 0.18 --- 0.47 11 --- 13 / 0.40 --- 0.47 1 4 --- 13 / 0.18 --- 0.47 11 --- 13 / 0.40 --- 0.47 0.14 0.14 0.14 0.14 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/3 1/2” NPT 195 / 115 20 --- 50 1/3 1/2” NPT 195 / 115 20 --- 50 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/4 3/4” NPT 195 / 115 35 --- 65 2/5 3/4” NPT 195 / 115 45 --- 75 2/4 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 40 --- 75 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 1/3 1/2” NPT 195 / 115 20 --- 50 1/3 1/2” NPT 195 / 115 20 --- 50 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/4 3/4” NPT 195 / 115 35 --- 65 2/5 3/4” NPT 195 / 115 45 --- 75 2/4 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 40 --- 75 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise --------- --------- # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise ----------------- ----------------- # of Gas Valves Nat. gas supply line press (in. w.g.) / (PSIG) LP supply line press (in. w.g.) / (PSIG) Heat Anticipator setting (Amps) HIGH MED LOW Natural Gas Heat HIGH MED LOW Liquid Propane Heat HIGH MED LOW Low NOx Gas Heat 7.5 - 8.5 TONS 580J**08 1st stage 2nd stage 15 580J Table 10 – PHYSICAL DATA Table 11 – PHYSICAL DATA (COOLING) 10 - 15 TONS 580J*12A 580J*12D 580J*14D 580J*16D 1 / 1 / Scroll 20 --- 0 ----Accutrol 630 / 505 54 / 117 --- 2 / 2 / Scroll 10 --- 5 / 10 --- 3 6 --- 0 / 6 --- 0 16 --- 10 / 16 --- 0 Accutrol 630 / 505 54 / 117 --- 2 / 2 / Scroll 11 --- 0 / 11 --- 6 7 --- 6 / 8 --- 0 17 --- 10 / 18 --- 3 Accutrol 630 / 505 54 / 117 --- 2 / 2 / Scroll 15 ---14/16 ---12 ----Accutrol 630 / 505 54 / 117 --- Cu / Al 3/8” RTPF 4 / 15 11.1 3/4” Cu / Al 3/8” RTPF 4 / 15 11.1 3/4” Cu / Al 3/8” RTPF 4 / 15 11.1 3/4” Cu / Al 3/8” RTPF 3 / 15 17.5 3/4” --------- Cu / Al 3/8” RTPF 2 / 17 8.4 Cu / Al 3/8” RTPF 2 / 17 8.4 --------- 1 / Belt 2.4 591 ---838 56 1 / Centrifugal 15 x 15 1 / Belt 3.7 838 ---1084 56 1 / Centrifugal 15 x 15 1 / Belt 4.7 1022 ---1240 14 1 / Centrifugal 15 x 15 1 / Belt 2.4 591 ---838 56 1 / Centrifugal 15 x 15 1 / Belt 3.7 838 ---1084 56 1 / Centrifugal 15 x 15 1 / Belt 4.7 1022 ---1240 14 1 / Centrifugal 15 x 15 1 / Belt 2.9 652 ---843 56 1 / Centrifugal 15 x 15 1 / Belt 3.7 838 ---1084 56 1 / Centrifugal 15 x 15 1 / Belt 4.7 1022 ---1240 14 1 / Centrifugal 15 x 15 1 / Belt 2.9 507 ---676 56 1 / Centrifugal 18 x 18 1 / Belt 3.7 627 ---851 56 1 / Centrifugal 18 x 18 1 / Belt 6.1 776 ---955 S184T 1 / Centrifugal 18 x 18 1 / Belt 6.1 776 ---955 S184T 1 / Centrifugal 18 x 18 Refrigeration System # Circuits / # Comp. / Type RTPF models R---410a charge A/B (lbs --- oz) Alternate (MCHX) R---410a charge A/B (lbs --- oz) Alternate (Perfect Humidity) R---410a charge A/B (lbs --- oz) Metering device High ---press. Trip / Reset (psig) Low---press. Trip / Reset (psig) Loss of charge Trip / Reset (psig) Evap. Coil Material Coil type Rows / FPI total face area (ft2) Condensate drain conn. size Perfect Humidity Coil 580J Material Coil type Rows / FPI total face area (ft2) High Static --High Efficiency 3 phase* High Static 3 phase Medium Static 3 phase Standard Static 3 phase Evap. fan and motor Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) Motor Qty / Drive type Max BHP RPM range motor frame size Fan Qty / Type Fan Diameter (in) 15 x 15 Cond. Coil Material Coil type Rows / FPI total face area (ft2) Cu / Al 3/8” RTPF 2 / 17 25.1 Cu / Al 3/8” RTPF 2 / 17 25.1 Cu / Al 3/8” RTPF 3 / 17 25.1 Cu / Al 3/8” RTPF 2/17 2 @ 23.1 Material Coil type Rows / FPI total face area (ft2) --------- Al / Al Novation™ 1 / 20 25.1 Al / Al Novation™ 2 / 20 25.1 --------- Qty / Motor drive type Motor HP / RPM Fan diameter (in) 2 / direct 1/4 / 1100 22 2 / direct 1/4 / 1100 22 1 / direct 1 / 1175 30 3 / direct 1/4 / 1100 22 RA Filter # / Size (in) 4 / 20 x 20 x 2 4 / 20 x 20 x 2 4 / 20 x 20 x 2 Alternate (MCHX) Cond. Coil Cond. fan / motor Filters 16 / 18 x 24 x 2 V2 / 24 x 27 x 1 OA inlet screen # / Size (in) 1 / 20 x 24 x 1 1 / 20 x 24 x 1 1 / 20 x 24 x 1 H1 / 30 x 39 x 1 NOTE: Perfect Humidity is not available with Novation condenser coil models. Only Round Tube/Plate Fin (RTPF) up to 14 size. * Section 313 of the Energy Independence and Security Act of 2007 (EISA 2007) mandates that the efficiency of general purpose motors we use in our Light Commercial Rooftops rated at 5.0HP and larger be increased on or after December 19, 2010. We will offer both high and standard efficient motors until inventory is depleted and then shift over solely to the high efficient motors only. 16 Gas Connection 580J**14 580J**16 # of Gas Valves Nat. gas supply line press (in. w.g.) / (PSIG) 1 4 --- 13 / 0.18 --- 0.47 LP supply line press (in. w.g.) / (PSIG) 11 --- 13 / 0.40 --- 0.47 1 4 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 1 5 --- 13 / 0.18 --0.47 11 --- 13 / 0.40 --0.47 0.14 0.14 0.14 0.14 0.14 0.14 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/4 3/4” NPT 195 / 115 25 --- 65 2/4 3/4” NPT 195 / 115 25 --- 65 2/6 3/4” NPT 225 / 145 20 --- 55 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/5 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 35 --- 70 2/5 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 35 --- 70 2/8 3/4” NPT 225 / 145 25 --- 60 2 / 10 3/4” NPT 225 / 145 35 --- 65 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/4 3/4” NPT 195 / 115 25 --- 65 2/4 3/4” NPT 195 / 115 25 --- 65 2/6 3/4” NPT 225 / 145 20 --- 55 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise 2/5 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 35 --- 70 2/5 3/4” NPT 195 / 115 30 --- 65 2/5 3/4” NPT 195 / 115 35 --- 70 2/8 3/4” NPT 225 / 145 25 --- 60 2 / 10 3/4” NPT 225 / 145 35 --- 65 # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise --------- --------- # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise # of stages / # of burners (total) Connection Size Rollout switch opens / closes Temperature Rise ----------------- ----------------- HIGH MED LOW Natural Gas Heat HIGH MED LOW Liquid Propane Heat LOW Low NOx Gas Heat MED 10 - 15 TONS 580J**12 Heat Anticipator setting (Amps) HIGH (HEATING) 1st stage 2nd stage 17 580J Table 12 – PHYSICAL DATA 580J CURBS & WEIGHTS DIMENSIONS -- 580J 04--07 C101225 Fig. 1 -- Dimensions 580J 04--07 18 580J CURBS & WEIGHTS DIMENSIONS -- 580J 04--07 (cont.) C101226 Fig. 2 -- Dimensions 580J 04--07 C D B A C08337 Fig. 3 -- Service Clearance LOC A B C D DIMENSION 48--- in (1219 mm) 18--- in (457 mm) 18--- in (457 mm) 12--- in (305 mm) 42--- in (1067 mm) 36--- in (914 mm) Special 36--- in (914 mm) 18--- in (457 mm) 48--- in (1219 mm) 42--- in (1067 mm) 36--- in (914 mm) Special CONDITION Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance Surface behind servicer is grounded (e.g., metal, masonry wall) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for sources of flue products within 10--- ft of unit fresh air intake hood Side condensate drain is used Minimum clearance No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10--- ft of this unit’s flue outlet 19 CURBS & WEIGHTS DIMENSIONS -- 580J 04--07 (cont.) CONNECTOR PKG. ACCY. CRBTMPWR001A01 C D ALT DRAIN HOLE 1’-9 11/16” [551] 1’-4” [406] 1 3/4” [44.5] GAS [19] NPT POWER CONTROL ACCESSORY POWER 3/4” 1/2” [12.7] NPT 3/4” [19] NPT 1/2” [12.7] NPT 1/2” [12.7] NPT ROOFCURB ACCESSORY A CRRFCURB001A01 1’-2” [356] CRRFCURB002A01 2’-0” [610] UNIT SIZE 580J* 04-07 NOTES: 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. 3. Dimensions in [ ] are in millimeters. 4. Roof curb: galvanized steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance: 4 ft on each side. 7. Direction of airflow. 8. Connector package CRBTMPWR001A01 is for thru-the-curb type gas. CRBTMPWR003A01 is for thru-the-base type gas connections. 580J CRBTMPWR003A01 B TYPICAL CORNER FASTENING DEVICE C10480 Fig. 4 -- Roof Curb Details 20 580J CURBS & WEIGHTS DIMENSIONS -- 580J 08--12 C101217 Fig. 5 -- Dimensions 580J 08--12 21 580J CURBS & WEIGHTS DIMENSIONS -- 580J 08--12 (cont.) C101218 Fig. 6 -- 580J 08--12 C D B A C08337 Fig. 7 -- Service Clearance LOC A B C D DIMENSION 48--- in (1219 mm) 36--- in (914 mm) 18--- in (457 mm) 18--- in (457 mm) 12--- in (305 mm) 36--- in (914 mm) 12--- in (305 mm) Special 36--- in (914 mm) 18--- in (457 mm) 48--- in (1219 mm) 42--- in (1067 mm) 36--- in (914 mm) Special CONDITION Unit disconnect is mounted on panel If dimension--- B is 12--- in (305 mm) No disconnect, convenience outlet option Recommended service clearance (use electric screwdriver) Minimum clearance (use manual ratchet screwdriver) Unit has economizer If dimension--- A is 36--- in (914 mm) Check for sources of flue products within 10--- ft of unit fresh air intake hood Side condensate drain is used Minimum clearance No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10--- ft of this unit’s flue outlet 22 CURBS & WEIGHTS DIMENSIONS -- 580J 08--14 ROOFCURB ACCESSORY CRRFCURB004A01 1’ - 2” (356) 2’ - 0” (610) 580J*08 – 14 580J CRRFCURB003A01 UNIT SIZE TYPICAL CORNER FASTENING DEVICE C10481 Fig. 8 -- Roof Curb Details 23 580J CURBS & WEIGHTS DIMENSIONS -- 580J 14 C101223 Fig. 9 -- Dimensions 580J--14 24 580J CURBS & WEIGHTS DIMENSIONS -- 580J 14 (cont.) C101224 C D B A C08337 Fig. 10 -- Service Clearance LOC A B C D DIMENSION 48--- in (1219 mm) 36--- in (914 mm) 18--- in (457 mm) 18--- in (457 mm) 12--- in (305 mm) 36--- in (914 mm) 12--- in (305 mm) Special 36--- in (914 mm) 18--- in (457 mm) 48--- in (1219 mm) 42--- in (1067 mm) 36--- in (914 mm) Special CONDITION Unit disconnect is mounted on panel If dimension--- B is 12--- in (305 mm) No disconnect, convenience outlet option Recommended service clearance (use electric screwdriver) Minimum clearance (use manual ratchet screwdriver) Unit has economizer If dimension--- A is 36--- in (914 mm) Check for sources of flue products within 10--- ft of unit fresh air intake hood Side condensate drain is used Minimum clearance No flue discharge accessory installed, surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non--- conductive (e.g., wood, fiberglass) Check for adjacent units or building fresh air intakes within 10--- ft of this unit’s flue outlet 25 580J CURBS & WEIGHTS DIMENSIONS -- 580J 16 C101231 26 580J CURBS & WEIGHTS DIMENSIONS -- 580J 16 (cont.) C101232 27 580J CURBS & WEIGHTS DIMENSIONS -- 580J 16 C10772 28 04 05 lb kg lb kg Perfect Humidity1 15 7 23 10 Power Exhaust --- vertical 50 23 50 23 Power Exhaust --- horizontal 30 14 30 14 EconoMi$er(IV or 2) 50 23 50 23 Two Position damper 39 18 39 18 Manual Dampers 12 5 12 5 Medium Gas Heat 12 5 9 4 High Gas Heat --- --- 17 8 Hail Guard (louvered) 16 7 16 7 Cu/Cu Condenser Coil2 6 3 13 6 Cu/Cu Condenser and Evaporator Coils2 12 5 19 9 Roof Curb (14---in. curb) 115 52 115 52 Roof Curb (24---in. curb) 197 89 197 89 CO2 sensor 5 2 5 2 Flue Discharge Deflector 7 3 7 3 Optional Indoor Motor/Drive 10 5 10 5 Motor Master Controller 35 16 35 16 Return Smoke Detector 5 2 5 2 Supply Smoke Detector 5 2 5 2 Non ---Fused Disconnect 15 7 15 7 Powered Convenience outlet 35 16 35 16 Non ---Powered Convenience outlet 5 2 5 2 Enthalpy Sensor 2 1 2 1 Differential Enthalpy Sensor 3 1 3 1 OPTION / ACCESSORY OPTION / ACCESSORY WEIGHTS 06 07 08 09 12 lb kg lb kg lb kg lb kg lb kg 25 11 29 13 38 17 47 21 47 21 50 23 50 23 75 34 75 34 75 34 30 14 30 14 30 14 30 14 30 14 50 23 50 23 75 34 75 34 75 34 39 18 39 18 58 26 58 26 58 26 12 5 12 5 18 8 18 8 18 8 9 4 9 4 15 7 15 7 18 8 17 8 17 8 29 13 29 13 35 16 16 7 16 7 34 15 34 15 34 15 13 6 15 7 12 5 23 10 23 10 21 10 26 12 25 11 49 22 49 22 115 52 115 52 143 65 143 65 143 65 197 89 197 89 245 111 245 111 245 111 5 2 5 2 5 2 5 2 5 2 7 3 7 3 7 3 7 3 7 3 10 5 10 5 15 7 15 7 15 7 35 16 35 16 35 16 35 16 35 16 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 5 2 15 7 15 7 15 7 15 7 15 7 35 16 35 16 35 16 35 16 35 16 5 2 5 2 5 2 5 2 5 2 2 1 2 1 2 1 2 1 2 1 3 1 3 1 3 1 3 1 3 1 NOTE: Where multiple variations are available, the heaviest combination is listed. 1 For Perfect Humidity add MotorMaster Controller. 2 Where available. 29 14 lb kg 47 21 75 34 30 14 75 34 58 26 18 8 18 8 35 16 34 15 23 10 49 22 143 65 245 111 5 2 7 3 15 7 40 18 5 2 5 2 15 7 35 16 5 2 2 1 3 1 16 lb kg na na 85 39 75 34 115 52 65 29 25 11 28 13 50 23 45 20 190 86 280 127 180 82 255 116 5 2 7 3 45 20 40 18 5 2 5 2 15 7 35 16 5 2 2 1 3 1 580J OPTIONS & ACCESSORY WEIGHTS APPLICATION DATA Min operating ambient temp (cooling): Outdoor air application strategies: In mechanical cooling mode, your Bryant rooftop unit can safely operate down to an outdoor ambient temperature of 40_F (4_C) and 25_F (-- 4_C), with an accessory winter start kit. It is possible to provide cooling at lower outdoor ambient temperatures by using less outside air, economizers, and/or accessory low ambient kits. Economizers reduce operating expenses and compressor run time by providing a free source of cooling and a means of ventilation to match application changing needs. In fact, they should be considered for most applications. Also, consider the various economizer control methods and their benefits, as well as sensors required to accomplish your application goals. Please contact your local Bryant representative for assistance. 580J Max operating ambient temp (cooling): The maximum operating ambient temperature for cooling mode is 115_F (46_C). While cooling operation above 115_F (46_C) may be possible, it could cause either a reduction in performance, reliability, or a protective action by the unit’s internal safety devices. Min mixed air temp (heating): Using the factory settings, the minimum temperatures for the mixed air (the combined temperature of the warm return air and the cold outdoor air) entering the dimpled, gas heat exchangers are: Aluminized 50_F (10_C) continuous 45_F (7_C) intermittent Stainless Steel 40_F (4_C) continuous 35_F (2_C) intermittent Operating at lower mixed-- air temperatures may be possible, if a field supplied, outdoor air thermostat initiates both heat stages when the temperature is less than the minimum temperatures listed above. Please contact your local Bryant representative for assistance. Min and max airflow (heating and cooling): To maintain safe and reliable operation of your rooftop, operate within the heating airflow limits during heating mode and cooling airflow limits during cooling mode. Operating above the max may cause blow-- off, undesired airflow noise, or airflow related problems with the rooftop unit. Operating below the min may cause problems with coil freeze-- up and unsafe heating operation. Heating and cooling limitations differ when evaluating operating CFM, the minimum value is the HIGHER of the cooling and heating minimum CFM values published in Table 7 and the maximum value is the LOWER of the cooling and heating maximum values published in Table 7. Heating--to--cooling changeover: Your unit will automatically change from heating to cooling mode when using a thermostat with an auto-- changeover feature. Airflow: All units are draw-- through in cooling mode and blow-- through in heating mode. Motor limits, Brake horsepower (BHP): Due to internal design of Bryant units, the air path, and specially designed motors, the full horsepower (maximum continuous BHP) band, as listed in Table 8 and 10, can be used with the utmost confidence. There is no need for extra safety factors, as Bryant motors are designed and rigorously tested to use the entire, listed BHP range without either nuisance tripping or premature motor failure. Propane heating: Propane has different physical qualities than natural gas. As a result, propane requires different fuel to air mixture. To optimize the fuel/air mixture for propane, Bryant sells different burner orifices in an easy to install accessory kit. To select the correct burner orifices or determine the heat capacity for a propane application, use either the selection software, or the unit’s service manual. High altitude heating: High altitudes have less oxygen, which affects the fuel/air mixture in heat exchangers. In order to maintain a proper fuel/air mixture, heat exchangers operating in altitudes above 2000 ft (610 m) require different orifices. To select the correct burner orifices or determine the heat capacity for a high altitude application, use either the selection software, or the unit’s service manual. High altitudes have less oxygen, which means heat exchangers need less fuel. The new gas orifices in this field installed kit make the necessary adjustment for high altitude applications. They restore the optimal fuel to air mixture and maintain healthy combustion on altitudes above 2000 ft (610 m). NOTE: Typical natural gas heating value ranges from 975 to 1050 Btu/ft3 at sea level nationally. The heating value goes down approximately 1.7% per every thousand feet elevation. Standard factory orifices can typically be used up to 2000 ft (610m) elevation without any operational issues. NOTE: For installations in Canada, the input rating should be derated by 10% for altitudes from 2000 ft (610m) to 4500 ft (1372m) above sea level. 30 Sizing a rooftop Low ambient applications Bigger isn’t necessarily better. While an air conditioner needs to have enough capacity to meet the design loads, it doesn’t need excess capacity. In fact, excess capacity typically results in very poor part load performance and humidity control. The optional Bryant economizer can adequately cool your space by bringing in fresh, cool outside air. In fact, when so equipped, accessory low ambient kit may not be necessary. In low ambient conditions, unless the outdoor air is excessively humid or contaminated, economizer based “free cooling” is the preferred less costly and energy conscious method. Using higher design temperatures than ASHRAE recommends for your location, adding “safety factors” to the calculated load, are all signs of oversizing air conditioners. Oversizing the air conditioner leads to poor humidity control, reduced efficiency, higher utility bills, larger indoor temperature swings, excessive noise, and increased wear and tear on the air conditioner. Rather than oversizing an air conditioner, engineers should “right size” or even slightly undersize air conditioners. Correctly sizing an air conditioner controls humidity better; promotes efficiency; reduces utility bills; extends equipment life, and maintains even, comfortable temperatures. Please contact your local Bryant representative for assistance. In low ambient applications where outside air might not be desired (such as contaminated or excessively humid outdoor environments), your Bryant rooftop can operate at ambient temperatures down to - 20_F (-- 29_C) using the recommended accessory Motormaster low ambient controller. 31 580J APPLICATION DATA (cont.) SELECTION PROCEDURE (WITH 580J*07A EXAMPLE)1 I. 580J II. Determine cooling and heating loads. Given: Mixed air dry bulb 80_F (27_C) Mixed air wet bulb 67_F (19_C) Ambient dry bulb 95_F (35_C) 72.0 MBH TCLoad SHCLoad 54.0 MBH Vertical supply air 2100 CFM Heating load 85.0 MBH External static pressure 0.67 in. wg Electrical characteristics 230-- 3-- 60 Make an initial guess at cooling tons. Refrig. tons = TCLoad / 12 MBH per ton Refrig. tons = 72.0 / 12 = 6.0 tons In this case, start by looking at the 580J**07. III. Look up the rooftop’s TC and SHC. Table 15 shows that, at the application’s supply air CFM, mixed air and ambient temperatures, the 580J*07A supplies: TC = 73.7 MBH2 SHC = 54.4 MBH2 IV. Local code requires an economizer for any unit with TC greater than 65.0 MBH. VIII. Calculate the total static pressure. External static pressure Sum of FIOP / Accessory static 0.67 in. wg +0.13 in. wg Total Static Pressure 0.80 in. wg IX. Look up the indoor fan RPM & BHP. Table 36 shows, at 2100 CFM & ESP= 0.8, RPM = 1358 & BHP = 1.52 X. Convert BHP (Step VIII) into fan motor heat. Fan motor heat = 2.546* BHP/Motor Eff.4 Fan motor heat = 4.9 MBH XI. Calculate RTU heating capacity. Building heating load Fan motor heat Required heating capacity XII. Select a gas heater. 85.0 MBH - 4.9 MBH 80.1 MBH Table 4 shows the heating capacities of the 580JE07A = 93.0 MBH. Select the 580JE07A Calculate the building latent heat load. LCLoad = TCLoad - SHCLoad LCLoad = 72.0 MBH - 54.0 MBH = 18.0 MBH V. VII. Select factory options (FIOP) XIII. Determine electrical requirements. Table 56 shows the MCA and MOCP of a 580J*07A (without convenience outlet) as: MCA = 30.5 amps & MOCP = 45.0 amps Min. disconnect size: FLA = 30 & LRA = 157. Calculate RTU latent heat capacity. LC = TC - SHC LC = 73.7 MBH - 54.4 MBH = 19.3 MBH VI. Compare RTU capacities to loads.3 Compare the rooftop’s SHC and LC to the building’s sensible and latent heat loads. LEGEND BHP — FLA — LC — LRA — MBH — MCA — MOCP — RPM — RTU — SHC — TC — Brake horsepower Full load amps Latent capacity Lock rotor amp (1,000) BTUH Min. circuit ampacity Max. over ---current protection Revolutions per minute Rooftop unit Sensible heat capacity Total capacity NOTES: 1. Selection software by Bryant saves time by performing many of the steps above. Contact your Bryant sales representative for assistance. 2. Unit ratings are gross capacities and do not include the effect of evaporator fan motor heat. See Step X. for determining amount of evaporator fan motor heat to subtract from total and sensible capacities to obtain net cooling and net sensible capacities. 3. Selecting a unit with a SHC slightly lower than the SHCLoad is often better than oversizing. Slightly lower SHC’s will help control indoor humidity, and prevent temperature swings. 4. Indoor fan motor efficiency is available in Table 45. Use the decimal form in the equation, eg. 80% = .8. 32 580J*04A (RTPF) 58 EAT (wb) 900 Cfm 62 67 72 76 58 EAT (wb) 1050 Cfm 62 67 72 76 58 EAT (wb) 1200 Cfm 62 67 72 76 58 EAT (wb) 1350 Cfm 62 67 72 76 58 EAT (wb) 1500 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 75 28.1 24.4 30.3 22.6 35.5 19.5 39.0 15.3 ----30.2 26.3 31.9 24.6 36.7 20.6 40.1 15.7 ----32.2 28.0 33.3 26.4 37.7 21.7 40.9 16.1 --------28.4 17.6 33.2 15.0 37.5 11.8 ----28.1 21.9 30.3 19.8 35.5 16.7 39.0 12.4 ----- 85 EAT (db) 80 28.1 28.1 30.3 26.8 35.5 23.7 39.0 19.5 41.4 16.0 30.2 30.2 31.9 29.4 36.7 25.4 40.1 20.5 42.4 16.6 32.2 32.2 33.3 31.7 37.7 27.0 40.9 21.5 43.1 17.1 ----28.4 24.1 33.2 21.4 37.5 18.3 40.1 15.3 28.1 28.1 30.3 26.8 35.5 23.7 39.0 19.5 41.4 16.0 1-- STAGE COOLING 85 31.7 31.7 31.0 31.0 35.5 27.9 39.0 23.7 41.4 21.0 34.2 34.2 34.2 34.2 36.7 30.2 40.1 25.3 42.4 22.2 36.4 36.4 37.0 37.0 37.7 32.4 40.9 26.8 43.1 23.1 ----30.5 30.5 33.2 27.9 37.5 24.8 40.1 22.7 34.2 34.2 33.8 33.8 35.5 30.7 39.0 26.6 41.4 24.3 75 26.3 22.9 27.8 21.5 33.1 18.5 37.1 14.5 ----28.4 24.7 29.4 23.4 34.8 19.8 38.2 15.0 ----30.4 26.4 30.8 25.1 35.6 20.9 39.0 15.4 ----32.1 27.9 32.2 26.6 36.4 21.9 39.7 15.8 ----33.7 29.3 33.7 27.8 36.9 22.8 40.2 16.1 ----- AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 26.3 29.8 24.5 24.5 26.3 29.8 21.3 24.5 27.8 29.8 25.1 25.1 25.7 29.8 20.2 24.3 33.1 33.1 30.5 30.5 22.7 26.9 17.4 21.6 37.1 37.1 35.1 35.1 18.8 23.0 13.7 17.9 39.6 39.6 --37.6 15.4 20.2 --14.6 28.4 32.2 26.5 26.5 28.4 32.2 23.1 26.5 29.4 32.8 26.7 26.7 28.1 32.8 22.0 26.6 34.8 34.8 32.2 32.2 24.6 29.4 18.8 23.6 38.2 38.2 36.1 36.1 19.8 24.6 14.2 19.0 40.6 40.6 --38.5 15.9 21.3 --15.2 30.4 34.3 28.4 28.4 30.4 34.3 24.7 28.4 30.8 35.5 28.4 28.4 30.3 35.5 23.4 28.4 35.6 35.6 33.4 33.4 26.3 31.6 20.0 25.4 39.0 39.0 36.9 36.9 20.8 26.1 14.7 20.0 41.3 41.3 --39.1 16.4 22.3 --15.7 32.1 36.3 30.0 30.0 32.1 36.3 26.1 30.0 32.2 37.8 30.1 30.1 32.2 37.8 24.8 30.1 36.4 36.4 34.1 34.1 27.8 33.7 21.0 26.9 39.7 39.7 37.5 37.5 21.7 27.5 15.0 20.9 41.8 41.8 --39.6 16.8 23.2 --16.1 33.7 38.1 31.6 31.6 33.7 38.1 27.4 31.6 33.7 39.6 31.6 31.6 33.7 39.6 26.1 31.6 36.9 36.9 34.6 34.6 29.2 35.7 21.9 28.4 40.2 40.2 38.0 38.0 22.5 28.8 15.4 21.7 42.2 42.2 --40.0 17.2 24.0 --16.5 Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 33 3 TONS 85 27.7 27.7 28.4 28.4 30.5 25.8 35.1 22.2 37.6 19.3 30.0 30.0 31.2 31.2 32.2 28.4 36.1 23.8 38.5 20.4 32.1 32.1 33.4 33.4 33.4 30.8 36.9 25.4 39.1 21.4 34.0 34.0 35.3 35.3 34.1 32.9 37.5 26.8 39.6 22.3 35.7 35.7 37.1 37.1 34.9 34.9 38.0 28.1 40.0 23.2 75 22.6 19.6 22.6 18.7 27.5 16.2 32.7 12.9 ----24.5 21.3 24.5 20.3 29.1 17.6 33.7 13.4 ----26.3 22.8 26.3 21.7 30.4 18.8 34.4 13.8 ----27.9 24.2 27.9 23.0 31.5 20.0 35.0 14.2 ----29.3 25.5 29.4 24.2 32.0 21.0 35.5 14.6 ----- 115 EAT (db) 80 22.6 22.6 22.6 22.6 27.5 20.4 32.7 17.1 35.4 13.8 24.5 24.5 24.5 24.5 29.1 22.4 33.7 18.2 36.2 14.4 26.3 26.3 26.3 26.3 30.4 24.2 34.4 19.2 36.8 14.9 27.9 27.9 27.9 27.9 31.5 26.0 35.0 20.1 37.3 15.3 29.3 29.3 29.4 29.4 32.0 27.5 35.5 21.0 ----- 85 25.5 25.5 26.5 26.5 27.5 24.6 32.7 21.3 35.4 18.3 27.7 27.7 28.8 28.8 29.1 27.2 33.7 23.0 36.2 19.5 29.7 29.7 30.9 30.9 30.4 29.6 34.4 24.5 36.8 20.5 31.5 31.5 32.8 32.8 32.0 32.0 35.0 26.0 37.3 21.5 33.2 33.2 34.5 34.5 34.0 34.0 35.5 27.4 ----- 580J Table 13 – COOLING CAPACITIES Table 14 – COOLING CAPACITIES Temp (F) Air Ent Condenser (Edb) 75 85 95 580J 105 115 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW Temp (F) Air Ent Condenser (Edb) 80 75 70 60 50 40 LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 1-- STAGE COOLING 580J04 (3 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE Air Entering Evaporator --- CFM 80 dry bulb 80 dry bulb 80 dry bulb 72 wet bulb 67 wet bulb 62 wet bulb 900 1200 1500 900 1200 1500 900 1200 40.6 43.2 45.3 37.0 39.4 41.3 33.4 35.6 21.6 23.9 25.6 25.6 27.7 29.3 29.6 31.6 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 37.0 39.6 41.7 33.6 36.0 37.9 30.2 32.3 17.7 20.2 22.2 22.7 25.0 26.9 27.7 29.9 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3 33.5 36.0 38.1 30.2 32.5 34.4 26.9 29.1 13.7 16.6 18.8 19.7 22.4 24.4 25.7 28.2 2.6 2.6 2.6 2.5 2.5 2.5 2.5 2.5 29.9 32.4 34.5 26.8 29.1 31.0 23.6 25.8 9.8 12.9 15.3 16.8 19.7 22.0 23.8 26.5 2.9 2.9 2.9 2.8 2.8 2.8 2.8 2.8 26.3 28.8 30.9 23.3 25.7 27.5 20.4 22.5 5.8 9.2 11.9 13.8 17.0 19.5 21.9 24.8 3.2 3.2 3.2 3.1 3.1 3.1 3.1 3.1 3 TONS 1500 37.4 33.1 2.0 34.1 31.6 2.3 30.8 30.1 2.5 27.5 28.6 2.8 24.2 27.1 3.1 580J04 (3 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE Air Entering Evaporator --- CFM 75 dry bulb 75 dry bulb 75 dry bulb 62.5 wet bulb (50% relative) 64 wet bulb (55% relative) 65.3 wet bulb (60% relative) 1050 1200 1350 1050 1200 1350 1050 1200 1350 14.7 15.5 16.2 15.9 16.7 17.4 16.9 17.7 18.4 6.7 7.6 8.5 4.8 5.7 6.6 3.2 4.1 5.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 15.1 15.8 16.4 16.2 17.0 17.6 17.2 18.0 18.6 7.5 8.4 9.2 5.8 6.7 7.5 4.4 5.2 6.0 1.9 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.0 15.5 16.1 16.7 16.6 17.3 17.9 17.5 18.2 18.8 8.4 9.3 10.0 6.9 7.7 8.5 5.5 6.4 7.1 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 16.2 16.8 17.3 17.2 17.8 18.3 18.1 18.7 19.2 10.2 10.9 11.6 8.9 9.7 10.4 7.8 8.6 9.3 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.9 1.9 17.0 17.5 17.9 17.9 18.4 18.8 18.7 19.2 19.6 11.9 12.6 13.2 11.0 11.6 12.2 10.1 10.8 11.4 1.7 1.7 1.7 1.8 1.8 1.8 1.8 1.8 1.8 17.7 18.1 18.5 18.6 19.0 19.3 19.3 19.7 20.1 13.7 14.3 14.8 13.0 13.6 14.1 12.4 13.0 13.5 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 34 EAT (wb) 1200 Cfm 62 67 72 76 58 EAT (wb) 1400 cfm 62 67 72 76 58 EAT (wb) 1600 Cfm 62 67 72 76 58 EAT (wb) 1800 Cfm 62 67 72 76 58 EAT (wb) 2000 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 4 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 ----36.1 36.1 ----31.5 36.1 40.8 40.8 38.4 38.4 35.3 40.6 28.9 34.1 45.2 45.2 42.9 42.9 30.2 35.5 23.9 29.2 49.1 49.1 46.8 46.8 24.7 30.1 18.4 23.7 51.5 51.5 --49.2 20.2 26.8 --19.3 TC SHC TC SHC TC SHC TC SHC TC SHC 75 ----43.1 31.2 47.4 25.9 51.1 20.1 ----- 85 EAT (db) 80 ----43.1 36.4 47.4 31.2 51.1 25.5 53.3 20.8 TC SHC TC SHC TC SHC TC SHC TC SHC 41.9 36.6 44.6 33.4 48.7 27.3 52.2 20.6 ----- 41.9 41.9 44.6 39.4 48.7 33.2 52.2 26.7 54.1 21.5 47.3 47.3 45.4 45.4 48.7 39.2 52.2 32.7 54.1 29.0 40.1 35.0 42.3 32.3 46.6 26.4 50.3 19.9 ----- 40.1 40.1 42.3 38.3 46.6 32.3 50.3 25.9 52.3 20.8 45.3 45.3 44.2 44.2 46.6 38.3 50.3 32.0 52.3 28.0 38.2 33.3 39.8 31.0 44.2 25.3 47.8 18.9 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 44.0 38.3 45.7 35.3 49.8 28.4 53.0 21.0 ----- 44.0 44.0 45.7 42.0 49.8 35.0 53.0 27.6 54.6 22.0 49.6 49.6 48.6 48.6 49.8 41.6 53.0 34.3 54.6 29.9 42.1 36.7 43.5 34.2 47.6 27.6 51.1 20.3 ----- 42.1 42.1 43.5 40.8 47.6 34.2 51.1 27.0 52.8 21.3 47.4 47.4 47.5 47.5 47.6 40.9 51.1 33.6 52.8 29.0 TC SHC TC SHC TC SHC TC SHC TC SHC 44.0 37.6 45.7 34.5 49.8 27.6 53.0 20.2 ----- 44.0 44.0 45.7 42.0 49.8 35.0 53.0 27.6 54.6 22.0 50.3 50.3 49.5 49.5 49.8 42.5 53.0 35.1 54.6 30.9 42.1 36.0 43.5 33.4 47.6 26.8 51.1 19.5 ----- 42.1 42.1 43.5 40.8 47.6 34.2 51.1 27.0 52.8 21.3 TC SHC TC SHC TC SHC TC SHC TC SHC 46.9 40.9 47.5 38.5 51.2 30.5 54.0 21.7 ----- 46.9 46.9 47.5 46.3 51.2 38.3 54.0 29.2 55.2 22.7 52.9 52.9 54.0 54.0 51.2 46.0 54.0 36.8 55.2 31.4 45.0 39.3 45.3 37.3 49.1 29.8 52.1 21.1 ----- 45.0 45.0 45.3 44.9 49.1 37.6 52.1 28.7 53.5 22.0 580J*05A (RTPF) 58 1-- STAGE COOLING 85 ----43.1 41.7 47.4 36.4 51.1 30.9 53.3 27.4 75 ----40.8 30.1 45.2 25.0 49.1 19.4 ----- Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 35 85 40.7 40.7 39.4 39.4 42.9 34.4 46.8 29.0 49.2 25.7 75 34.3 29.9 35.9 27.8 40.3 22.9 43.9 17.4 ----- 115 EAT (db) 80 34.3 34.3 35.9 33.0 40.3 28.2 43.9 22.7 45.9 18.3 38.2 38.2 39.8 37.0 44.2 31.3 47.8 24.9 49.9 19.9 43.2 43.2 42.9 42.9 44.2 37.3 47.8 30.9 49.9 26.9 36.3 31.7 37.3 29.8 41.4 24.2 44.8 17.9 ----- 36.3 36.3 37.3 35.7 41.4 30.2 44.8 23.8 46.4 18.8 41.0 41.0 41.6 41.6 41.4 36.2 44.8 29.7 46.4 25.7 40.1 34.9 41.0 32.9 45.1 26.5 48.6 19.4 ----- 40.1 40.1 41.0 39.4 45.1 33.2 48.6 26.0 50.4 20.3 45.2 45.2 46.0 46.0 45.1 39.9 48.6 32.6 50.4 27.9 38.1 33.2 38.5 31.6 42.3 25.4 45.4 18.3 ----- 38.1 38.1 38.5 38.0 42.3 32.1 45.4 24.8 46.8 19.2 43.0 43.0 44.4 44.4 42.3 38.7 45.4 31.3 46.8 26.6 48.1 48.1 48.3 48.3 47.6 41.7 51.1 34.4 52.8 30.0 40.1 34.3 41.0 32.1 45.1 25.7 48.6 18.5 ----- 40.1 40.1 41.0 39.4 45.1 33.2 48.6 26.0 50.4 20.3 45.9 45.9 46.8 46.8 45.1 40.7 48.6 33.4 50.4 28.9 38.0 32.6 38.4 30.8 42.3 24.6 45.4 17.5 ----- 38.0 38.0 38.4 38.0 42.3 32.1 45.4 24.8 46.8 19.2 43.5 43.5 45.2 45.2 42.3 39.5 45.4 32.1 46.8 27.5 50.8 50.8 52.5 52.5 49.1 45.5 52.1 36.4 53.5 30.6 42.9 37.4 43.0 35.6 46.5 28.7 49.7 20.1 ----- 42.9 42.9 43.0 43.0 46.5 36.6 49.7 27.8 51.0 21.1 48.4 48.4 50.3 50.3 46.5 44.5 49.7 35.4 51.0 29.6 40.7 35.5 40.7 33.8 43.5 27.5 46.2 18.9 ----- 40.7 40.7 40.7 40.7 43.5 35.4 46.2 26.4 47.3 19.9 45.9 45.9 47.7 47.7 43.5 43.2 46.2 33.9 47.3 28.1 85 38.6 38.6 38.2 38.2 40.3 33.4 43.9 28.0 45.9 24.6 580J Table 15 – COOLING CAPACITIES Table 16 – COOLING CAPACITIES Temp (F) Air Ent Condenser (Edb) 75 85 95 580J 105 115 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW Temp (F) Air Ent Condenser (Edb) 80 75 70 60 50 40 LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 1-- STAGE COOLING 580J05 (4 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE Air Entering Evaporator --- CFM 80 dry bulb 80 dry bulb 80 dry bulb 72 wet bulb 67 wet bulb 62 wet bulb 1200 1600 2000 1200 1600 2000 1200 1600 52.5 55.9 58.6 47.1 50.2 52.7 41.7 44.5 22.6 25.5 27.8 27.1 29.9 32.0 31.6 34.2 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 48.7 52.2 54.9 43.4 46.5 49.0 38.0 40.8 18.0 21.3 23.9 23.6 26.8 29.2 29.3 32.2 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 44.9 48.4 51.2 39.6 42.8 45.3 34.3 37.1 13.4 17.2 20.0 20.2 23.7 26.4 27.0 30.2 3.4 3.4 3.4 3.3 3.3 3.3 3.3 3.3 41.1 44.7 47.5 35.9 39.1 41.7 30.6 33.5 8.8 13.0 16.1 16.7 20.6 23.6 24.6 28.2 3.8 3.8 3.8 3.7 3.7 3.7 3.7 3.7 37.4 41.0 43.9 32.1 35.4 38.0 26.8 29.8 4.3 8.8 12.2 13.3 17.5 20.7 22.3 26.2 4.2 4.2 4.2 4.2 4.2 4.2 4.1 4.1 4 TONS 2000 46.8 36.2 2.5 43.1 34.4 2.9 39.4 32.7 3.3 35.8 31.0 3.7 32.1 29.2 4.1 580J05 (4 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE Air Entering Evaporator --- CFM 75 dry bulb 75 dry bulb 75 dry bulb 62.5 wet bulb (50% relative) 64 wet bulb (55% relative) 65.3 wet bulb (60% relative) 1200 1600 2000 1200 1600 2000 1200 1600 2000 11.6 13.8 15.5 13.5 15.8 17.6 15.2 17.5 19.3 --- 1.0 1.2 3.0 --- 3.1 --- 0.8 0.9 --- 4.8 --- 2.6 --- 0.9 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 12.5 14.6 16.2 14.3 16.4 18.1 15.9 18.1 19.8 --- 0.7 1.4 3.0 --- 2.7 --- 0.6 1.1 --- 4.3 --- 2.2 --- 0.6 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 13.4 15.3 16.8 15.1 17.1 18.7 16.6 18.7 20.3 --- 0.5 1.5 3.0 --- 2.3 --- 0.3 1.2 --- 3.8 --- 1.9 --- 0.3 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 15.1 16.8 18.1 16.7 18.4 19.8 18.1 19.9 21.2 0.0 1.7 3.1 --- 1.5 0.2 1.5 --- 2.8 --- 1.1 0.2 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 16.9 18.3 19.4 18.3 19.8 20.9 19.6 21.0 22.2 0.6 2.0 3.1 --- 0.7 0.7 1.8 --- 1.8 --- 0.4 0.7 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 18.7 19.8 20.7 19.9 21.1 22.0 21.0 22.2 23.2 1.1 2.2 3.1 0.1 1.2 2.1 --- 0.8 0.4 1.3 2.6 2.6 2.6 2.7 2.7 2.7 2.7 2.7 2.7 Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 36 EAT (wb) 1500 Cfm 62 67 72 76 58 EAT (wb) 1750 Cfm 62 67 72 76 58 EAT (wb) 2000 Cfm 62 67 72 76 58 EAT (wb) 2250 Cfm 62 67 72 76 58 EAT (wb) 2500 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 5 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 49.9 56.6 46.6 46.6 49.9 56.6 40.4 46.6 52.2 55.7 47.8 47.8 47.8 55.7 37.8 45.6 58.8 58.8 54.4 54.4 41.2 49.1 31.4 39.3 64.8 64.8 60.8 60.8 33.9 41.9 24.4 32.4 69.0 69.0 --65.4 27.6 35.9 --26.3 TC SHC TC SHC TC SHC TC SHC TC SHC 75 52.9 45.8 56.2 41.8 62.4 34.8 68.2 27.2 ----- 85 EAT (db) 80 52.9 52.9 56.2 49.7 62.4 42.8 68.2 35.2 71.1 28.4 TC SHC TC SHC TC SHC TC SHC TC SHC 56.5 48.9 58.5 45.2 64.3 36.9 69.5 27.8 ----- 56.5 56.5 58.5 54.3 64.3 46.1 69.5 36.9 72.2 29.3 64.0 64.0 63.4 63.4 64.3 55.2 69.5 45.9 72.2 38.9 53.3 46.1 54.4 43.2 60.5 35.3 66.5 26.7 ----- 53.3 53.3 54.4 52.2 60.5 44.5 66.5 35.9 70.1 28.6 60.4 60.4 61.3 61.3 60.5 53.7 66.5 45.1 70.1 38.2 49.8 43.1 49.9 41.0 56.2 33.6 62.4 25.2 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 59.3 51.4 60.1 48.1 65.7 38.8 70.1 28.3 ----- 59.3 59.3 60.1 58.3 65.7 49.1 70.1 38.1 72.9 30.1 67.3 67.3 68.5 68.5 65.7 59.5 70.1 48.0 72.9 40.7 56.1 48.6 56.2 46.2 61.9 37.3 67.6 27.4 ----- 56.1 56.1 56.2 56.2 61.9 47.7 67.6 37.7 70.8 29.3 63.6 63.6 66.3 66.3 61.9 58.1 67.6 48.0 70.8 39.9 TC SHC TC SHC TC SHC TC SHC TC SHC 61.5 53.2 61.6 50.6 66.8 40.5 70.8 28.7 ----- 61.5 61.5 61.6 61.6 66.8 52.0 70.8 39.5 73.4 30.7 69.8 69.8 72.6 72.6 66.8 63.4 70.8 50.2 73.4 42.1 58.4 50.5 58.4 47.9 63.0 39.1 68.5 28.0 ----- 58.4 58.4 58.4 58.4 63.0 50.7 68.5 39.3 71.2 30.0 TC SHC TC SHC TC SHC TC SHC TC SHC 63.3 54.8 63.4 52.0 67.6 42.1 71.3 29.1 ----- 63.3 63.3 63.4 63.4 67.6 54.6 71.3 40.7 73.8 31.2 71.8 71.8 74.7 74.7 67.6 67.1 71.3 52.2 73.8 43.3 60.1 52.1 60.2 49.4 63.8 40.9 69.0 28.5 ----- 60.1 60.1 60.2 60.2 63.8 53.5 69.0 40.7 71.4 30.5 580J*06A (RTPF) 58 1-- STAGE COOLING 85 60.0 60.0 57.6 57.6 62.4 50.7 68.2 43.2 71.1 36.6 75 49.9 43.2 52.2 39.9 58.8 33.2 64.8 25.9 ----- Do not operate Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 37 85 52.9 52.9 53.5 53.5 54.4 47.3 60.8 40.4 65.4 34.6 75 43.1 37.3 43.2 35.5 49.5 29.4 56.2 22.6 ----- 115 EAT (db) 80 43.1 43.1 43.2 43.2 49.5 37.3 56.2 30.6 60.9 24.8 49.8 49.8 49.9 49.9 56.2 42.8 62.4 34.5 66.6 27.4 56.5 56.5 58.9 58.9 56.2 51.9 62.4 43.7 66.6 36.8 46.1 39.9 46.1 37.9 51.3 31.6 57.7 23.5 ----- 46.1 46.1 46.1 46.1 51.3 40.8 57.7 32.8 ----- 52.3 52.3 54.4 54.4 51.3 49.9 57.7 42.0 ----- 52.5 45.4 52.5 43.1 57.5 35.6 63.6 26.0 ----- 52.5 52.5 52.5 52.5 57.5 46.0 63.6 36.4 67.4 28.2 59.5 59.5 62.0 62.0 57.5 56.4 63.6 46.7 67.4 38.7 48.6 42.1 48.7 39.9 52.6 33.6 58.9 24.3 ----- 48.6 48.6 48.7 48.7 52.6 44.0 58.9 34.7 ----- 55.1 55.1 57.4 57.4 54.4 54.4 58.9 45.2 ----- 66.2 66.2 68.9 68.9 63.0 62.3 68.5 50.5 71.2 41.4 54.8 47.4 54.8 45.0 58.5 37.4 64.5 26.7 ----- 54.8 54.8 54.8 54.8 58.5 49.0 64.5 38.1 67.9 28.9 62.1 62.1 64.6 64.6 60.6 60.6 64.5 49.6 67.9 40.4 50.8 43.9 50.8 41.7 53.6 35.5 59.8 25.0 ----- 50.8 50.8 50.8 50.8 53.6 47.0 59.8 36.6 ----- 57.6 57.6 59.9 59.9 58.6 58.6 59.8 48.1 ----- 68.2 68.2 71.0 71.0 66.2 66.2 69.0 52.9 71.4 42.6 56.5 49.0 56.6 46.5 59.3 39.2 65.1 27.3 ----- 56.5 56.5 56.6 56.6 59.3 51.9 65.1 39.7 68.3 29.6 64.1 64.1 66.7 66.7 64.6 64.6 65.1 52.2 68.3 41.9 52.6 45.5 52.6 43.2 54.4 37.2 60.4 25.7 ----- 52.6 52.6 52.6 52.6 54.4 49.8 60.4 38.3 ----- 59.6 59.6 62.1 62.1 62.5 62.5 60.4 50.9 ----- 85 48.9 48.9 51.0 51.0 49.5 45.3 56.2 38.6 60.9 33.0 580J Table 17 – COOLING CAPACITIES Table 18 – COOLING CAPACITIES Temp (F) Air Ent Condenser (Edb) 75 85 95 580J 105 115 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW Temp (F) Air Ent Condenser (Edb) 80 75 70 60 50 40 LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 1-- STAGE COOLING 580J06 (5 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE Air Entering Evaporator --- CFM 80 dry bulb 80 dry bulb 80 dry bulb 72 wet bulb 67 wet bulb 62 wet bulb 1750 2000 2250 1750 2000 2250 1750 2000 73.1 78.7 84.5 63.2 66.9 70.8 53.2 55.1 35.3 37.2 38.8 42.0 43.7 45.3 48.7 50.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 3.3 67.6 71.2 75.0 59.1 61.2 63.3 50.6 51.1 27.9 30.0 31.9 36.3 38.3 40.1 44.8 46.6 3.8 3.8 3.8 3.8 3.8 3.8 3.8 3.8 62.1 63.8 65.5 55.1 55.4 55.8 48.0 47.0 20.5 22.9 24.9 30.7 32.9 34.8 40.9 42.9 4.3 4.3 4.3 4.3 4.3 4.3 4.3 4.3 56.6 56.3 56.0 51.0 49.6 48.3 45.4 43.0 13.1 15.7 18.0 25.0 27.5 29.6 36.9 39.2 4.8 4.8 4.8 4.8 4.8 4.8 4.7 4.7 51.1 48.8 46.5 46.9 43.9 40.7 42.8 39.0 5.8 8.6 11.0 19.4 22.0 24.4 33.0 35.5 5.3 5.3 5.3 5.3 5.3 5.3 5.2 5.2 5 TONS 2250 57.1 51.8 3.3 51.5 48.2 3.8 46.0 44.7 4.3 40.5 41.2 4.7 35.0 37.7 5.2 580J06 (5 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE Air Entering Evaporator --- CFM 75 dry bulb 75 dry bulb 75 dry bulb 62.5 wet bulb (50% relative) 64 wet bulb (55% relative) 65.3 wet bulb (60% relative) 1750 2000 2250 1750 2000 2250 1750 2000 2250 23.0 24.4 25.6 24.7 26.2 27.4 26.3 27.7 29.0 5.3 6.1 6.8 3.2 4.0 4.7 1.4 2.2 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 23.3 24.6 25.7 25.0 26.3 27.5 26.4 27.8 29.0 5.1 5.8 6.5 3.1 3.9 4.5 1.4 2.2 2.8 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 2.9 23.5 24.8 25.9 25.2 26.4 27.5 26.6 27.9 29.0 4.8 5.5 6.2 3.0 3.7 4.3 1.4 2.1 2.8 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 24.1 25.2 26.1 25.6 26.7 27.7 26.9 28.0 29.0 4.3 5.0 5.5 2.8 3.4 3.9 1.4 2.0 2.6 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 24.7 25.6 26.4 26.1 27.0 27.8 27.2 28.2 29.0 3.8 4.4 4.8 2.5 3.1 3.5 1.4 2.0 2.4 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 25.3 26.0 26.7 26.5 27.3 27.9 27.6 28.3 29.0 3.3 3.8 4.2 2.3 2.8 3.1 1.4 1.9 2.3 3.1 3.1 3.1 3.2 3.2 3.2 3.2 3.2 3.2 Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 38 EAT (wb) 1800 Cfm 62 67 72 76 58 EAT (wb) 2100 Cfm 62 67 72 76 58 EAT (wb) 2400 Cfm 62 67 72 76 58 EAT (wb) 2700 Cfm 62 67 72 76 58 EAT (wb) 3000 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 6 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 62.1 70.0 58.9 58.9 62.1 70.0 51.4 58.9 64.9 68.5 60.8 60.8 59.2 68.5 47.9 57.2 71.7 71.7 67.4 67.4 50.5 59.8 39.3 48.6 78.5 78.5 73.7 73.7 41.3 50.6 30.0 39.3 83.3 83.3 --77.7 33.5 43.4 --31.6 TC SHC TC SHC TC SHC TC SHC TC SHC 75 64.9 56.6 68.7 51.7 75.6 42.8 82.6 33.5 ----- 85 EAT (db) 80 64.9 64.9 68.7 61.0 75.6 52.2 82.6 42.8 87.5 35.0 TC SHC TC SHC TC SHC TC SHC TC SHC 68.9 60.1 70.9 55.6 77.8 45.4 84.5 34.5 ----- 68.9 68.9 70.9 66.3 77.8 56.1 84.5 45.2 89.2 36.3 77.7 77.7 76.9 76.9 77.8 66.8 84.5 55.9 89.2 47.8 65.9 57.4 67.1 53.8 73.7 43.7 80.3 32.9 ----- 65.9 65.9 67.1 64.4 73.7 54.4 80.3 43.5 84.7 34.7 74.3 74.3 75.0 75.0 73.7 65.2 80.3 54.2 84.7 46.0 62.5 54.5 63.0 51.6 69.2 41.8 75.1 30.9 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 72.0 62.8 72.8 59.1 79.4 47.7 86.0 35.3 ----- 72.0 72.0 72.8 71.0 79.4 59.8 86.0 47.2 90.3 37.3 81.2 81.2 82.8 82.8 79.4 71.8 86.0 59.2 90.3 49.8 68.7 60.0 68.9 57.2 75.2 46.0 81.6 33.7 ----- 68.7 68.7 68.9 68.9 75.2 58.1 81.6 45.6 85.7 35.6 77.5 77.5 80.7 80.7 75.2 70.2 81.6 57.5 85.7 48.0 TC SHC TC SHC TC SHC TC SHC TC SHC 60.3 46.4 65.4 41.0 72.7 33.8 79.7 25.8 ----- 60.3 60.3 65.4 55.1 72.7 48.0 79.7 40.2 85.1 33.5 74.1 74.1 69.3 69.3 72.7 62.2 79.7 54.6 85.1 48.4 71.1 62.0 71.2 59.0 76.3 48.2 82.5 34.5 ----- 71.1 71.1 71.2 71.2 76.3 61.6 82.5 47.5 86.4 36.5 TC SHC TC SHC TC SHC TC SHC TC SHC 64.9 51.1 68.7 45.5 75.6 36.6 82.6 27.2 ----- 64.9 64.9 68.7 61.0 75.6 52.2 82.6 42.8 87.5 35.0 78.8 78.8 76.5 76.5 75.6 67.7 82.6 58.5 87.5 51.5 73.1 63.8 73.2 60.7 77.2 50.2 83.3 35.1 ----- 73.1 73.1 73.2 73.2 77.2 64.8 83.3 49.2 86.9 37.3 580J*07A (RTPF) 58 1-- STAGE COOLING 85 73.3 73.3 70.3 70.3 75.6 61.5 82.6 52.2 87.5 44.9 75 62.1 54.1 64.9 49.9 71.7 41.2 78.5 31.9 ----- Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 39 85 66.4 66.4 66.4 66.4 67.4 58.0 73.7 48.6 77.7 41.5 75 55.6 48.5 56.4 45.7 62.5 37.2 67.8 27.8 ----- 115 EAT (db) 80 55.6 55.6 56.4 54.9 62.5 46.5 67.8 36.9 70.9 29.3 62.5 62.5 63.0 62.1 69.2 52.5 75.1 41.4 78.8 32.6 70.5 70.5 72.5 72.5 69.2 63.2 75.1 52.0 78.8 43.7 58.7 51.2 58.7 48.7 64.0 39.6 68.8 28.5 ----- 58.7 58.7 58.7 58.7 64.0 50.2 68.8 38.7 71.6 30.1 66.2 66.2 68.7 68.7 64.0 60.7 68.8 48.9 71.6 40.9 65.2 56.9 65.2 54.1 70.5 44.0 76.1 31.7 ----- 65.2 65.2 65.2 65.2 70.5 56.0 76.1 43.3 79.6 33.5 73.5 73.5 76.4 76.4 70.5 68.1 76.1 55.0 79.6 45.6 61.1 53.3 61.2 50.7 65.1 41.6 69.6 29.1 ----- 61.1 61.1 61.2 61.2 65.1 53.5 69.6 40.3 72.1 30.8 68.9 68.9 71.6 71.6 65.3 65.3 69.6 51.4 72.1 42.5 80.2 80.2 83.3 83.3 76.3 74.9 82.5 60.5 86.4 49.9 67.4 58.8 67.5 55.9 71.5 46.1 76.9 32.3 ----- 67.4 67.4 67.5 67.5 71.5 59.3 76.9 45.0 80.2 34.3 76.0 76.0 79.0 79.0 72.6 72.6 76.9 57.7 80.2 47.3 63.0 55.0 63.1 52.3 65.8 43.5 70.1 29.7 ----- 63.0 63.0 63.1 63.1 65.8 56.5 70.1 41.7 72.5 31.5 71.1 71.1 73.8 73.8 69.4 69.4 70.1 53.8 72.5 44.0 82.5 82.5 85.7 85.7 79.4 79.4 83.3 63.3 86.9 51.6 69.2 60.3 69.2 57.4 72.2 48.0 77.5 32.9 ----- 69.2 69.2 69.2 69.2 72.2 62.4 77.5 46.6 80.6 35.0 78.0 78.0 81.0 81.0 76.8 76.8 77.5 60.3 80.6 48.9 64.5 56.2 64.5 53.5 66.3 45.1 70.5 30.2 ----- 64.5 64.5 64.5 64.5 66.3 59.1 70.5 43.0 72.8 32.1 72.7 72.7 75.5 75.5 73.0 73.0 70.5 55.9 72.8 45.3 85 62.7 62.7 64.0 64.0 62.5 55.8 67.8 45.9 70.9 39.1 580J Table 19 – COOLING CAPACITIES Table 20 – COOLING CAPACITIES Temp (F) Air Ent Condenser (Edb) 75 85 95 580J 105 115 TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW Temp (F) Air Ent Condenser (Edb) 80 75 70 60 50 40 LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW TC SHC kW 1-- STAGE COOLING 580J07 (6 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE Air Entering Evaporator --- CFM 80 dry bulb 80 dry bulb 80 dry bulb 72 wet bulb 67 wet bulb 62 wet bulb 2100 2400 2700 2100 2400 2700 2100 2400 86.7 89.9 92.8 79.3 82.3 84.9 71.9 74.6 40.1 41.8 43.3 46.9 48.5 49.9 53.7 55.2 4.3 4.3 4.3 4.2 4.2 4.2 4.2 4.2 79.5 82.6 85.4 72.5 75.3 77.9 65.4 68.0 32.1 34.0 35.7 40.7 42.5 44.1 49.4 51.0 5.0 5.0 5.0 5.0 5.0 5.0 4.9 4.9 72.4 75.3 78.1 65.6 68.3 70.8 58.8 61.3 24.1 26.3 28.1 34.6 36.6 38.3 45.1 46.9 5.8 5.8 5.8 5.7 5.7 5.7 5.6 5.6 65.2 68.1 70.7 58.7 61.4 63.8 52.3 54.7 16.2 18.5 20.5 28.5 30.6 32.6 40.7 42.8 6.5 6.5 6.5 6.4 6.4 6.4 6.3 6.3 58.0 60.8 63.3 51.9 54.4 56.7 45.7 48.0 8.2 10.7 13.0 22.3 24.7 26.8 36.4 38.6 7.2 7.2 7.2 7.1 7.1 7.1 7.0 7.0 6 TONS 2700 77.0 56.5 4.2 70.3 52.5 4.9 63.6 48.5 5.6 56.8 44.6 6.3 50.1 40.6 7.0 580J07 (6 TONS) --- UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE Air Entering Evaporator --- CFM 75 dry bulb 75 dry bulb 75 dry bulb 62.5 wet bulb (50% relative) 64 wet bulb (55% relative) 65.3 wet bulb (60% relative) 2100 2400 2700 2100 2400 2700 1750 2000 2700 16.7 19.8 22.5 18.8 21.9 24.7 16.2 19.4 26.7 0.6 0.6 0.6 --- 0.4 --- 0.4 --- 0.4 --- 1.3 --- 1.3 --- 1.3 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 17.7 20.6 23.1 19.6 22.6 25.3 17.3 20.3 27.1 0.6 0.6 0.6 --- 0.3 --- 0.3 --- 0.3 --- 1.2 --- 1.2 --- 1.2 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 18.6 21.3 23.7 20.5 23.3 25.8 18.3 21.1 27.6 0.7 0.7 0.7 --- 0.2 --- 0.2 --- 0.2 --- 1.0 --- 1.0 --- 1.0 4.0 4.0 4.0 4.1 4.1 4.1 4.1 4.1 4.1 20.5 22.9 25.0 22.2 24.7 26.8 20.4 22.8 28.5 0.7 0.7 0.7 --- 0.0 --- 0.0 --- 0.0 --- 0.7 --- 0.7 --- 0.7 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 4.1 22.4 24.4 26.2 24.0 26.0 27.9 22.4 24.5 29.3 0.8 0.8 0.8 0.1 0.1 0.1 --- 0.4 --- 0.4 --- 0.4 4.1 4.1 4.1 4.1 4.1 4.1 4.2 4.2 4.2 24.3 25.9 27.4 25.7 27.4 28.9 24.5 26.3 30.2 0.8 0.8 0.8 0.3 0.3 0.3 --- 0.1 --- 0.1 --- 0.1 4.1 4.1 4.1 4.2 4.2 4.2 4.2 4.2 4.2 Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 40 EAT (wb) 2250 Cfm 62 67 72 76 58 EAT (wb) 2625 Cfm 62 67 72 76 58 EAT (wb) 3000 Cfm 62 67 72 76 58 EAT (wb) 3375 Cfm 62 67 72 76 58 EAT (wb) 3750 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 7.5 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 77.5 87.7 73.6 73.6 77.5 87.7 63.9 73.6 82.3 84.0 77.2 77.2 72.7 84.0 58.9 70.2 90.7 90.7 85.7 85.7 62.2 73.6 48.8 60.1 98.9 98.9 93.8 93.8 51.2 62.7 37.7 49.2 104.8 104.8 --99.1 42.0 54.3 --40.0 TC SHC TC SHC TC SHC TC SHC TC SHC 85 EAT (db) 75 80 85 81.2 81.2 91.8 70.5 81.2 91.8 86.9 86.9 86.9 63.6 74.9 86.2 95.2 95.2 95.2 52.8 64.2 75.6 103.5 103.5 103.5 41.5 53.1 64.6 --109.6 109.6 --43.7 56.0 75 77.5 67.3 82.3 61.4 90.7 50.9 98.9 39.7 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 85.9 74.6 89.6 68.1 97.9 55.7 106.0 42.7 ----- 85.9 85.9 89.6 81.1 97.9 68.7 106.0 55.8 111.8 45.3 97.2 97.2 94.1 94.1 97.9 81.7 106.0 68.9 111.8 59.8 82.2 71.4 85.1 65.9 93.2 53.7 101.3 40.9 ----- 82.2 82.2 85.1 78.8 93.2 66.7 101.3 53.9 106.9 43.6 93.1 93.1 91.7 91.7 93.2 79.8 101.3 67.0 106.9 58.0 78.1 67.9 80.1 63.4 88.1 51.6 95.9 38.8 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 89.6 77.9 91.8 72.2 99.9 58.3 107.9 43.7 ----- 89.6 89.6 91.8 86.7 99.9 72.9 107.9 58.3 113.8 46.7 101.4 101.4 101.1 101.1 99.9 87.5 107.9 72.8 113.8 62.5 85.9 74.6 87.2 69.9 95.2 56.4 103.0 41.9 ----- 85.9 85.9 87.2 84.3 95.2 71.0 103.0 56.4 108.4 44.8 97.2 97.2 98.6 98.6 95.2 85.5 103.0 70.9 108.4 60.4 TC SHC TC SHC TC SHC TC SHC TC SHC 92.7 80.5 93.7 75.8 101.5 60.8 109.4 44.6 ----- 92.7 92.7 93.7 91.6 101.5 76.9 109.4 60.5 115.1 47.8 104.9 104.9 107.3 107.3 101.5 93.0 109.4 76.4 115.1 64.9 88.8 77.1 89.1 73.5 96.7 58.8 104.3 42.8 ----- 88.8 88.8 89.1 89.1 96.7 74.9 104.3 58.6 109.5 45.9 TC SHC TC SHC TC SHC TC SHC TC SHC 95.3 82.7 95.5 78.7 102.8 63.1 110.6 45.5 ----- 95.3 95.3 95.5 95.5 102.8 80.6 110.6 62.7 116.1 48.9 107.8 107.8 112.2 112.2 102.8 98.2 110.6 79.9 116.1 67.0 91.3 79.3 91.3 75.3 97.9 61.2 105.4 43.5 ----- 91.3 91.3 91.3 91.3 97.9 78.7 105.4 60.7 110.3 46.8 580J*08A (RTPF) 58 1-- STAGE COOLING Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 41 85 83.3 83.3 81.5 81.5 85.7 71.5 93.8 60.6 99.1 52.4 75 69.5 60.4 71.9 56.3 79.9 46.3 87.3 35.3 ----- 115 EA (db) 80 69.5 69.5 71.9 67.6 79.9 57.6 87.3 46.6 91.6 37.4 78.1 78.1 80.1 76.3 88.1 64.6 95.9 51.8 100.7 41.4 88.4 88.4 89.1 89.1 88.1 77.6 95.9 64.7 100.7 55.6 73.9 64.1 74.6 60.6 82.0 49.0 89.0 36.2 ----- 73.9 73.9 74.6 73.3 82.0 62.0 89.0 48.9 92.7 38.7 83.6 83.6 86.0 86.0 82.0 74.9 89.0 61.7 92.7 52.6 81.7 71.0 82.3 67.2 89.9 54.2 97.3 39.7 ----- 81.7 81.7 82.3 81.3 89.9 68.8 97.3 54.1 102.0 42.6 92.5 92.5 95.5 95.5 89.9 83.4 97.3 68.4 102.0 57.9 77.0 66.9 77.1 63.5 83.6 51.6 90.1 37.0 ----- 77.0 77.0 77.1 77.1 83.6 66.1 90.1 51.0 93.4 39.6 87.1 87.1 90.6 90.6 83.6 80.5 90.1 65.0 93.4 54.7 100.5 100.5 104.7 104.7 96.7 91.0 104.3 74.4 109.5 62.7 84.6 73.4 84.6 69.8 91.3 56.7 98.4 40.5 ----- 84.6 84.6 84.6 84.6 91.3 72.8 98.4 56.2 102.8 43.5 95.7 95.7 99.5 99.5 91.3 88.9 98.4 71.8 102.8 60.1 79.6 69.1 79.6 65.6 84.8 53.9 90.9 37.7 ----- 79.6 79.6 79.6 79.6 84.8 69.8 90.9 52.8 94.0 40.4 90.0 90.0 93.6 93.6 85.7 85.7 90.9 68.0 94.0 56.5 103.3 103.3 107.4 107.4 97.9 96.3 105.4 77.8 110.3 64.8 86.9 75.5 87.0 71.7 92.3 59.0 99.2 41.3 ----- 86.9 86.9 87.0 87.0 92.3 76.5 99.2 58.1 103.5 44.4 98.3 98.3 102.2 102.2 94.0 94.0 99.2 75.0 103.5 62.0 81.7 70.9 81.7 67.4 85.7 56.0 91.5 38.3 ----- 81.7 81.7 81.7 81.7 85.7 73.2 91.5 54.5 94.5 41.1 92.4 92.4 96.0 96.0 90.5 90.5 91.5 70.7 94.5 58.1 85 78.7 78.7 78.8 78.8 79.9 68.9 87.3 57.8 91.6 49.8 580J Table 21 – COOLING CAPACITIES Table 22 – COOLING CAPACITIES 580J*08D (RTPF & Novation) 58 EAT (wb) 2250 Cfm 62 67 72 76 580J 58 EAT (wb) 2625 Cfm 62 67 72 76 58 EAT (wb) 3000 Cfm 62 67 72 76 58 EAT (wb) 3375 Cfm 62 67 72 76 58 EAT (wb) 3750 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 2-- STAGE COOLING 85 EAT (db) 80 85 77.4 87.8 77.4 87.8 82.2 83.9 72.4 83.9 90.1 90.1 61.8 73.3 98.0 98.0 50.7 62.4 104.3 104.3 41.7 54.0 75 73.8 63.9 77.5 58.6 86.0 48.5 94.0 37.5 ----- 7.5 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 73.8 83.8 70.1 70.1 73.8 83.8 60.6 70.1 77.5 81.7 72.6 72.6 70.1 81.7 56.3 67.7 86.0 86.0 81.4 81.4 60.1 71.6 46.5 58.1 94.0 94.0 89.5 89.5 49.2 60.9 35.8 47.5 100.4 100.4 --95.9 40.3 52.7 --38.7 85 79.5 79.5 79.2 79.2 81.4 69.7 89.5 59.2 95.9 51.0 75 66.0 57.1 67.3 53.6 75.9 44.2 84.3 33.8 ----- 115 EA (db) 80 66.0 66.0 67.3 65.0 75.9 55.8 84.3 45.5 90.7 36.8 74.4 74.4 75.4 73.7 83.6 62.8 91.7 50.3 98.0 40.2 84.4 84.4 86.7 86.7 83.6 76.1 91.7 63.7 98.0 54.1 70.0 60.6 70.2 57.6 78.3 47.2 86.4 35.0 ----- 70.0 70.0 70.2 70.2 78.3 60.6 86.4 48.4 92.7 38.4 79.5 79.5 82.9 82.9 78.3 73.9 86.4 61.8 92.7 52.2 78.0 67.5 78.2 64.1 85.2 52.1 93.3 38.0 ----- 78.0 78.0 78.2 78.2 85.2 67.1 93.3 53.0 99.5 41.6 88.6 88.6 92.3 92.3 85.2 82.2 93.3 68.0 99.5 57.0 73.5 63.6 73.6 60.3 79.8 49.9 87.9 36.0 ----- 73.5 73.5 73.6 73.6 79.8 65.0 87.9 51.1 94.2 39.8 83.4 83.4 86.9 86.9 80.1 80.1 87.9 66.2 94.2 55.2 96.4 96.4 100.4 100.4 91.5 89.6 99.4 73.4 105.4 61.3 81.0 70.1 81.1 66.5 86.6 54.6 94.6 38.9 ----- 81.0 81.0 81.1 81.1 86.6 71.3 94.6 55.5 100.7 42.8 92 92 95.7 95.7 87.9 87.9 94.6 72.0 100.7 59.7 76.5 66.1 76.5 62.7 81.1 52.4 89.1 37.0 ----- 76.5 76.5 76.5 76.5 81.1 69.1 89.1 53.7 95.3 41.0 86.8 86.8 90.3 90.3 85.8 85.8 89.1 70.3 95.3 58.0 99.1 99.1 103.1 103.1 95.1 95.1 100.5 77.1 106.2 63.6 83.3 72.0 83.3 68.3 87.6 56.9 95.6 39.8 ----- 83.3 83.3 83.3 83.3 87.6 75.2 95.6 57.8 101.6 44.0 94.5 94.5 98.4 98.4 93.4 93.4 95.6 75.9 101.6 62.3 78.8 68.2 78.9 64.7 82.1 54.8 90.1 37.9 ----- 78.8 78.8 78.9 78.9 82.1 73.0 90.1 56.1 96.1 42.2 89.4 89.4 93.1 93.1 91.2 91.2 90.1 74.3 96.1 60.6 TC SHC TC SHC TC SHC TC SHC TC SHC 75 77.4 66.9 82.2 60.8 90.1 50.2 98.0 39.1 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 82.1 71.0 84.9 65.4 92.5 53.0 100.4 40.2 ----- 82.1 82.1 84.9 78.6 92.5 66.3 100.4 53.5 106.5 43.3 93.2 93.2 91.8 91.8 92.5 79.5 100.4 66.7 106.5 57.6 78.4 67.8 80.4 63.2 88.3 51.3 96.4 38.7 ----- 78.4 78.4 80.4 76.3 88.3 64.6 96.4 52.0 102.6 41.8 89.0 89.0 89.5 89.5 88.3 78.0 96.4 65.3 102.6 55.9 74.4 64.3 75.4 60.6 83.6 49.4 91.7 36.9 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 85.7 74.1 86.9 69.3 94.3 55.6 102.2 41.2 ----- 85.7 85.7 86.9 84.0 94.3 70.5 102.2 56.0 108.1 44.5 97.3 97.3 98.7 98.7 94.3 85.4 102.2 70.7 108.1 60.2 82.2 71.1 82.8 67.2 90.1 54.0 98.1 39.7 ----- 82.2 82.2 82.8 81.8 90.1 68.9 98.1 54.6 104.2 43.2 93.3 93.3 96.4 96.4 90.1 83.9 98.1 69.5 104.2 58.7 TC SHC TC SHC TC SHC TC SHC TC SHC 88.5 76.5 88.9 72.3 95.8 58.0 103.6 42.0 ----- 88.5 88.5 88.9 88.1 95.8 74.4 103.6 58.3 109.2 45.6 100.4 100.4 103.9 103.9 95.8 90.9 103.6 74.5 109.2 62.6 85.0 73.5 85.1 69.7 91.5 56.4 99.4 40.6 ----- 85.0 85.0 85.1 85.1 91.5 73.0 99.4 57.0 105.4 44.4 TC SHC TC SHC TC SHC TC SHC TC SHC 90.8 78.5 90.9 74.5 97.0 60.3 104.7 42.9 ----- 90.8 90.8 90.9 90.9 97.0 78.2 104.7 60.5 110.2 46.7 103.0 103.0 107.2 107.2 97.0 96.2 104.7 78.1 110.2 64.8 87.3 75.5 87.4 71.6 92.6 58.8 100.5 41.4 ----- 87.3 87.3 87.4 87.4 92.6 76.9 100.5 59.3 106.2 45.4 Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 42 85 74.9 74.9 76.4 76.4 75.9 67.4 84.3 57.2 90.7 49.0 2-- STAGE COOLING 580J08 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE AIR ENTERING EVAPORATOR --- CFM 2250/0.05 3000/0.07 3750/0.09 TEMP (F) AIR ENT CONDENSER (Edb) Air Entering Evaporator --- Ewb (F) 72 67 62 72 67 62 72 67 TC 103.05 93.02 83.60 109.77 99.52 90.08 114.01 103.69 75 SHC 43.66 55.34 67.09 50.99 66.29 81.31 57.49 76.27 kW 4.90 4.83 4.77 4.82 4.88 4.96 4.99 4.91 TC 95.39 85.83 76.88 101.59 91.89 82.95 105.53 95.76 85 SHC 36.42 48.47 60.60 43.24 58.99 74.40 49.44 68.68 kW 5.49 5.42 5.36 5.40 5.47 5.54 5.58 5.50 TC 87.48 78.44 69.97 93.21 84.05 75.61 96.84 87.63 95 SHC 28.98 41.46 53.97 35.32 51.53 67.34 41.21 60.92 kW 6.16 6.09 6.03 6.08 6.14 6.21 6.24 6.17 TC 79.35 70.83 62.84 84.57 75.96 68.04 87.88 79.23 105 SHC 21.34 34.26 47.18 27.17 43.86 60.08 32.73 52.95 kW 6.93 6.86 6.81 6.85 6.91 6.97 7.00 6.93 TC 70.87 62.89 55.42 75.58 67.54 60.15 78.56 70.51 115 SHC 13.40 26.79 40.14 18.70 35.89 52.54 23.94 44.68 kW 7.79 7.74 7.69 7.73 7.78 7.83 7.86 7.80 7.5 TONS 62 95.19 92.20 4.85 87.77 84.90 5.44 80.14 77.41 6.11 72.26 69.70 6.88 64.06 61.67 7.76 580J08 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE AIR ENTERING EVAPORATOR --- Ewb (F) 75 Dry Bulb 75 Dry Bulb 75 Dry Bulb 62.5 Wet Bulb 64 Wet Bulb 65.3 Wet Bulb TEMP (F) AIR ENT (50% Relative) (56% Relative) (60% Relative) CONDENSER (Edb) Air Entering Evaporator --- Cfm 2250 3000 3750 2250 3000 3750 2250 3000 3750 TC 27.60 32.75 30.19 40.09 39.43 37.73 45.06 45.25 44.25 80 SHC --- 3.12 5.20 6.71 3.75 5.24 6.75 3.77 5.26 6.78 kW 4.56 4.51 4.46 4.63 4.60 4.56 4.70 4.67 4.64 TC 35.40 33.78 31.20 41.14 40.51 38.80 46.15 46.37 45.38 75 SHC 4.67 6.17 7.69 4.71 6.21 7.73 4.74 6.24 7.76 kW 4.41 4.36 4.39 4.41 4.36 4.36 4.41 4.39 4.36 TC 36.36 34.71 32.18 42.10 41.47 39.77 47.08 47.31 46.32 70 SHC 5.63 7.14 8.66 5.67 7.18 8.71 5.70 7.21 8.74 kW 4.43 4.49 4.41 4.44 4.40 4.39 4.49 4.47 4.44 TC 38.25 36.64 34.15 43.97 43.37 41.72 48.98 49.22 48.26 60 SHC 7.56 9.09 10.62 7.60 9.13 10.66 7.62 9.15 10.69 kW 4.56 4.55 4.43 4.57 4.53 4.46 4.56 4.55 4.50 TC 40.15 38.60 36.14 45.95 45.37 43.73 50.57 50.97 49.56 50 SHC 9.48 11.03 12.58 9.52 11.07 12.62 9.54 11.10 12.64 kW 4.63 4.52 4.38 4.45 4.41 4.33 5.25 4.91 5.60 TC 42.18 40.62 38.11 47.80 47.25 45.43 52.65 52.75 51.83 40 SHC 11.41 12.98 14.54 11.45 13.02 14.58 11.47 13.04 14.60 kW 4.32 4.37 4.37 4.65 4.60 4.89 4.96 5.20 5.12 NOTE: Perfect Humidity only available on 2--- stage RTPF models. NOTES: LEGEND 1. Direct interpolation is permissible. Do not extrapolate. Edb --- Entering Dry--- Bulb 2. The following formulas may be used: Ewb --- Entering Wet--- Bulb kW --- Compressor Motor Power Input sensible capacity (Btuh) tldb = tedb – Idb --- Leaving Dry--- Bulb 1.10 x cfm Iwb --- Leaving Wet--- Bulb tlwb = Wet--- bulb temperature corresponding to enthalpy of air SHC --- Sensible Heat Capacity (1000 Btuh) Gross leaving evaporator coil (hlwb) TC --- Total Capacity (1000 Btuh) Gross total capacity (Btuh) hlwb = hewb – 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil 43 580J Table 23 – COOLING CAPACITIES Table 24 – COOLING CAPACITIES EAT (wb) 2550 Cfm 62 67 72 76 580J 58 EAT (wb) 2975 Cfm 62 67 72 76 58 EAT (wb) 3400 Cfm 62 67 72 76 58 EAT (wb) 3825 Cfm 62 67 72 76 58 EAT (wb) 4250 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 8.5 TONS TC SHC TC SHC TC SHC TC SHC TC SHC 85 EAT (db) 75 80 85 88.1 88.1 99.9 76.4 88.1 99.9 93.9 93.9 95.2 69.4 82.3 95.2 103.8 103.8 103.8 57.8 70.7 83.6 113.1 113.1 113.1 45.2 58.3 71.3 --119.9 119.9 --47.9 61.9 AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 75 80 85 75 80 85 84.1 84.1 95.3 79.6 79.6 90.3 72.8 84.1 95.3 69.0 79.6 90.3 88.6 88.6 92.6 82.8 82.8 89.7 66.8 79.7 92.6 64.1 76.9 89.7 98.7 98.7 98.7 93.0 93.0 93.0 55.6 68.5 81.4 53.1 66.1 79.0 108.0 108.0 108.0 102.4 102.4 102.4 43.2 56.3 69.3 41.1 54.1 67.1 --114.7 114.7 --109.0 109.0 --46.0 60.1 --44.1 58.1 75 74.9 64.9 76.6 61.0 86.7 50.5 96.1 38.7 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 93.6 81.1 97.5 74.7 106.7 61.0 115.8 46.5 ----- 93.6 93.6 97.5 89.5 106.7 75.8 115.8 61.3 122.4 49.8 106.1 106.1 104.3 104.3 106.7 90.6 115.8 76.2 122.4 66.1 89.3 77.4 92.0 72.0 101.5 58.8 110.6 44.5 ----- 89.3 89.3 92.0 86.7 101.5 73.6 110.6 59.4 117.0 47.8 101.2 101.2 101.4 101.4 101.5 88.5 110.6 74.2 117.0 63.9 84.6 73.3 86.1 69.1 95.7 56.4 104.9 42.3 ----- 84.6 84.6 86.1 83.7 95.7 71.3 104.9 57.2 111.1 45.7 96.0 96.0 98.3 98.3 95.7 86.1 104.9 72.1 111.1 61.6 79.6 69.0 79.8 65.6 89.2 53.8 98.4 40.0 ----- 79.6 79.6 79.8 79.8 89.2 68.7 98.4 54.8 104.5 43.4 90.3 90.3 94.1 94.1 89.2 83.6 98.4 69.7 104.5 59.0 TC SHC TC SHC TC SHC TC SHC TC SHC 98.1 85.0 100.0 79.3 109.0 63.9 117.9 47.6 ----- 98.1 98.1 100.0 95.8 109.0 80.5 117.9 64.1 124.2 51.2 111.3 111.3 112.3 112.3 109.0 97.2 117.9 80.6 124.2 69.0 93.7 81.2 94.9 76.3 103.6 61.8 112.5 45.6 ----- 93.7 93.7 94.9 92.5 103.6 78.5 112.5 62.1 118.6 49.2 106.2 106.2 108.6 108.6 103.6 95.2 112.5 78.7 118.6 66.7 88.9 77.0 89.1 73.2 97.6 59.4 106.6 43.4 ----- 88.9 88.9 89.1 89.1 97.6 76.1 106.6 60.0 112.5 47.0 100.8 100.8 104.9 104.9 97.6 92.9 106.6 76.6 112.5 64.4 83.7 72.5 83.8 68.8 91.0 56.8 100.0 41.1 ----- 83.7 83.7 83.8 83.8 91.0 73.5 100.0 57.6 105.7 44.7 94.9 94.9 98.7 98.7 91.0 90.3 100.0 74.2 105.7 61.9 TC SHC TC SHC TC SHC TC SHC TC SHC 101.6 88.0 101.9 83.7 110.7 66.7 119.4 48.5 ----- 101.6 101.6 101.9 101.8 110.7 85.0 119.4 66.6 125.5 52.4 115.1 115.1 120.0 120.0 110.7 103.4 119.4 84.6 125.5 71.5 97.2 84.2 97.3 79.9 105.3 64.6 114.0 46.6 ----- 97.2 97.2 97.3 97.3 105.3 83.0 114.0 64.7 119.8 50.4 110.1 110.1 114.6 114.6 105.3 101.5 114.0 82.7 119.8 69.3 92.3 80.0 92.4 75.9 99.2 62.2 108.0 44.4 ----- 92.3 92.3 92.4 92.4 99.2 80.8 108.0 62.6 113.6 48.2 104.6 104.6 108.9 108.9 99.3 99.3 108.0 80.7 113.6 67.0 87.0 75.4 87.1 71.6 92.5 59.6 101.3 42.1 ----- 87.0 87.0 87.1 87.1 92.5 78.2 101.3 60.2 106.7 45.9 98.6 98.6 102.6 102.6 96.7 96.7 101.3 78.4 106.7 64.4 TC SHC TC SHC TC SHC TC SHC TC SHC 104.4 90.4 104.4 85.8 112.1 69.2 120.7 49.4 ----- 104.4 104.4 104.4 104.4 112.1 89.2 120.7 68.9 126.6 53.5 118.3 118.3 123.0 123.0 112.1 109.2 120.7 88.4 126.6 73.9 99.9 86.6 99.9 82.1 106.6 67.2 115.1 47.4 ----- 99.9 99.9 99.9 99.9 106.6 87.3 115.1 67.0 120.8 51.5 113.2 113.2 117.8 117.8 107.5 107.5 115.1 86.5 120.8 71.7 95.0 82.3 95.0 78.1 100.4 64.9 109.0 45.3 ----- 95.0 95.0 95.0 95.0 100.4 85.1 109.0 64.9 114.5 49.3 107.6 107.6 112.0 112.0 105.3 105.3 109.0 84.6 114.5 69.4 89.5 77.6 89.6 73.6 93.6 62.3 102.2 42.9 ----- 89.5 89.5 89.6 89.6 93.6 82.5 102.2 62.6 107.4 46.9 101.5 101.5 105.6 105.6 102.7 102.7 102.2 82.3 107.4 66.8 580J*09A (RTPF) 58 1-- STAGE COOLING Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 44 115 EAT (db) 80 85 74.9 84.9 74.9 84.9 76.6 86.5 73.8 86.5 86.7 86.7 63.4 76.4 96.1 96.1 51.7 64.7 102.7 102.7 41.9 55.8 TC SHC TC SHC TC SHC TC SHC TC SHC 75 89.7 77.8 94.3 71.0 105.0 59.0 115.9 46.4 ----- EAT (wb) 2550 Cfm 62 67 72 76 58 TC SHC TC SHC TC SHC TC SHC TC SHC 95.3 82.6 97.9 76.7 108.5 62.8 119.1 47.9 ----- 95.3 95.3 97.9 92.2 108.5 78.4 119.1 63.5 126.4 51.1 107.9 107.9 107.8 107.8 108.5 94.1 119.1 79.2 126.4 67.4 90.7 78.6 92.1 73.9 102.6 60.4 113.5 45.8 ----- 90.7 90.7 92.1 89.3 102.6 76.0 113.5 61.5 120.8 49.2 102.7 102.7 104.7 104.7 102.6 91.7 113.5 77.1 120.8 65.3 84.8 73.5 85.4 69.6 95.4 57.4 107.2 43.5 ----- EAT (wb) 2975 Cfm 62 67 72 76 58 TC SHC TC SHC TC SHC TC SHC TC SHC 100.0 86.7 101.1 81.5 111.1 66.2 121.3 49.2 ----- 100.0 100.0 101.1 98.7 111.1 83.9 121.3 66.7 128.3 52.7 113.3 113.3 115.8 115.8 111.1 101.6 121.3 84.3 128.3 70.7 95.2 82.6 95.7 78.2 105.1 63.9 115.6 47.1 ----- 95.2 95.2 95.7 94.9 105.1 81.6 115.6 64.7 122.6 50.7 107.9 107.9 111.7 111.7 105.1 99.3 115.6 82.3 122.6 68.6 EAT (wb) 3400 Cfm 62 67 72 76 58 TC SHC TC SHC TC SHC TC SHC TC SHC 104.0 90.2 104.2 85.7 113.1 69.4 123.0 50.3 ----- 104.0 104.0 104.2 104.2 113.1 89.1 123.0 69.7 129.7 54.0 117.8 117.8 122.7 122.7 113.1 108.8 123.0 89.0 129.7 73.7 99.1 86.0 99.3 81.7 107.1 67.1 117.2 48.3 ----- 99.1 99.1 99.3 99.3 107.1 86.8 117.2 67.7 124.0 52.1 EAT (wb) 3825 Cfm 62 67 72 76 58 TC SHC TC SHC TC SHC TC SHC TC SHC 107.4 93.1 107.5 88.4 114.7 72.5 124.3 51.3 ----- 107.4 107.4 107.5 107.5 114.7 94.0 124.3 72.4 130.7 55.3 121.7 121.7 126.6 126.6 115.6 115.6 124.3 93.4 130.7 76.5 102.5 88.9 102.6 84.4 108.7 70.2 118.5 49.3 ----- 102.5 102.5 102.6 102.6 108.7 91.8 118.5 70.5 125.0 53.5 EAT (wb) 4250 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 85 101.6 101.6 97.9 97.9 105.0 86.1 115.9 73.6 123.7 63.3 75 85.2 73.9 88.7 68.2 99.3 56.6 110.4 44.3 ----- 8.5 TONS AMBIENT TEMPERATURE 95 105 EA (dB) EA (dB) 80 85 75 80 85.2 96.5 79.6 79.6 85.2 96.5 69.0 79.6 88.7 95.2 81.3 81.3 81.7 95.2 64.7 78.1 99.3 99.3 92.2 92.2 70.1 83.7 53.6 67.1 110.4 110.4 104.2 104.2 57.9 71.5 41.9 55.5 118.3 118.3 --112.4 47.3 61.4 --45.3 85 EA (dB) 80 89.7 89.7 94.3 84.4 105.0 72.6 115.9 60.0 123.7 49.3 580J*09D (RTPF) 58 2-- STAGE COOLING 85 90.1 90.1 91.5 91.5 92.2 80.7 104.2 69.1 112.4 59.3 75 73.8 64.0 74.3 60.6 84.1 50.3 96.0 38.8 ----- 115 EA (dB) 80 73.8 73.8 74.3 73.6 84.1 63.8 96.0 52.4 105.7 42.9 84.8 84.8 85.4 84.5 95.4 73.1 107.2 59.2 114.8 47.0 96.1 96.1 99.4 99.4 95.4 88.8 107.2 74.9 114.8 63.0 78.7 68.2 78.8 64.8 86.9 54.0 99.2 40.6 ----- 78.7 78.7 78.8 78.8 86.9 69.7 99.2 56.3 108.2 44.8 89.1 89.1 92.8 92.8 86.9 85.3 99.2 72.0 108.2 60.7 89.3 77.4 89.4 73.5 97.8 61.0 109.4 44.9 ----- 89.3 89.3 89.4 89.4 97.8 78.7 109.4 62.5 116.3 48.6 101.1 101.1 105.3 105.3 97.8 96.5 109.4 80.2 116.3 66.4 82.9 71.8 83.0 68.2 89.1 57.5 101.5 42.1 ----- 82.9 82.9 83.0 83.0 89.1 75.3 101.5 59.9 109.7 46.4 93.9 93.9 97.7 97.7 93.0 93.0 101.5 77.7 109.7 64.2 112.3 112.3 116.9 116.9 107.1 106.5 117.2 87.1 124.0 71.7 93.2 80.8 93.3 76.7 99.9 64.3 110.9 46.1 ----- 93.2 93.2 93.3 93.3 99.9 84.1 110.9 65.6 117.5 50.0 105.5 105.5 109.8 109.8 103.8 103.8 110.9 85.2 117.5 69.5 86.5 75.0 86.6 71.2 91.0 60.9 103.3 43.5 ----- 86.5 86.5 86.6 86.6 91.0 80.6 103.3 63.3 110.8 47.8 97.9 97.9 101.9 101.9 100.3 100.3 103.3 83.0 110.8 67.4 116.1 116.1 120.8 120.8 113.5 113.5 118.5 91.7 125.0 74.6 96.5 83.7 96.6 79.5 101.7 67.5 112.1 47.2 ----- 96.5 96.5 96.6 96.6 101.7 89.2 112.1 68.5 118.5 51.3 109.3 109.3 113.7 113.7 110.8 110.8 112.1 89.9 118.5 72.4 89.5 77.6 89.6 73.7 92.6 64.0 104.7 44.7 ----- 89.5 89.5 89.6 89.6 92.6 85.6 104.7 66.4 111.6 49.2 101.4 101.4 105.5 105.5 107.2 107.2 104.7 88.1 111.6 70.3 Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 45 85 83.6 83.6 86.5 86.5 84.1 77.3 96.0 65.9 105.7 56.7 580J Table 25 – COOLING CAPACITIES 580J Table 26 – COOLING CAPACITIES 2-- STAGE COOLING 580J09 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE AIR ENTERING EVAPORATOR --- CFM 2550/0.04 3400/0.05 4250/0.07 TEMP (F) AIR ENT CONDENSER (Edb) Air Entering Evaporator --- Ewb (F) 72 67 62 72 67 62 72 67 TC 119.20 107.44 96.41 126.95 114.98 103.92 131.87 119.81 75 SHC 50.63 63.94 77.40 59.17 76.72 94.21 66.80 88.44 kW 5.67 5.57 5.47 5.54 5.63 5.74 5.79 5.68 TC 110.40 99.22 88.76 117.63 106.26 95.77 122.21 110.77 85 SHC 42.39 56.16 70.07 50.42 68.45 86.38 57.71 79.86 kW 6.33 6.23 6.14 6.20 6.30 6.40 6.45 6.34 TC 101.37 90.79 80.86 108.07 97.31 87.39 112.29 101.47 95 SHC 33.97 48.22 62.56 41.46 60.01 78.39 48.40 71.09 kW 7.08 6.99 6.90 6.96 7.05 7.16 7.20 7.09 TC 92.04 82.06 72.71 98.19 88.05 78.72 102.07 91.86 105 SHC 25.31 40.06 54.88 32.24 51.33 70.17 38.85 62.06 kW 7.94 7.85 7.77 7.83 7.91 8.01 8.06 7.95 TC 82.37 73.01 64.24 87.95 78.45 69.73 91.46 81.90 115 SHC 16.38 31.65 46.95 22.71 42.37 61.69 28.94 52.74 kW 8.92 8.84 8.77 8.82 8.89 8.98 9.02 8.93 8.5 TONS 62 109.54 108.22 5.59 101.07 99.95 6.25 92.38 91.47 7.01 83.40 82.67 7.87 74.09 73.52 8.86 580J09 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE AIR ENTERING EVAPORATOR --- Ewb (F) 75 Dry Bulb 75 Dry Bulb 75 Dry Bulb 62.5 Wet Bulb 64 Wet Bulb 65.3 Wet Bulb TEMP (F) AIR ENT (50% Relative) (56% Relative) (60% Relative) CONDENSER (Edb) Air Entering Evaporator --- Cfm 2550 3400 4250 2550 3400 4250 2550 3400 4250 TC 37.61 33.13 26.77 44.74 41.60 36.46 50.96 48.99 44.93 80 SHC --- 0.52 --- 0.63 --- 0.73 --- 0.46 --- 0.57 --- 0.67 --- 0.42 --- 0.53 --- 0.62 kW 5.88 5.68 5.44 6.13 5.97 5.76 6.35 6.24 6.06 TC 38.71 34.24 27.86 45.84 42.73 37.59 52.05 50.11 46.06 75 SHC 0.45 0.34 0.25 0.50 0.40 0.31 0.54 0.44 0.36 kW 5.68 5.47 5.22 5.94 5.78 5.56 6.18 6.07 5.88 TC 39.70 35.25 28.83 46.80 43.70 38.59 52.97 51.04 47.02 70 SHC 1.41 1.32 1.23 1.47 1.37 1.29 1.50 1.41 1.34 kW 5.65 5.42 5.24 5.97 5.79 5.53 6.26 6.13 5.91 TC 41.77 37.33 30.76 48.86 45.80 40.71 55.00 53.10 49.12 60 SHC 3.34 3.26 3.18 3.40 3.32 3.25 3.43 3.36 3.29 kW 5.42 5.15 5.17 5.80 5.59 5.30 6.16 6.01 5.75 TC 43.83 39.27 32.61 50.92 47.89 42.70 57.04 55.16 51.22 50 SHC 5.27 5.21 5.14 5.32 5.27 5.21 5.36 5.31 5.25 kW 5.18 5.15 5.17 5.62 5.39 5.05 6.04 5.87 5.59 TC 45.75 41.13 34.50 53.08 50.00 44.64 59.24 57.40 53.44 40 SHC 7.20 7.15 6.95 7.26 7.21 7.16 7.29 7.25 7.21 kW 4.79 4.98 4.80 5.25 5.01 5.23 5.68 5.51 5.21 NOTE: Perfect Humidity only available on 2--- stage RTPF models. NOTES: LEGEND 1. Direct interpolation is permissible. Do not extrapolate. Edb --- Entering Dry--- Bulb 2. The following formulas may be used: Ewb --- Entering Wet--- Bulb kW --- Compressor Motor Power Input sensible capacity (Btuh) tldb = tedb – Idb --- Leaving Dry--- Bulb 1.10 x cfm Iwb --- Leaving Wet--- Bulb tlwb = Wet--- bulb temperature corresponding to enthalpy of air SHC --- Sensible Heat Capacity (1000 Btuh) Gross leaving evaporator coil (hlwb) TC --- Total Capacity (1000 Btuh) Gross total capacity (Btuh) hlwb = hewb – 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil 46 EAT (wb) 3000 Cfm 62 67 72 76 58 EAT (wb) 3500 Cfm 62 67 72 76 58 EAT (wb) 4000 Cfm 62 67 72 76 58 EAT (wb) 4500 Cfm 62 67 72 76 58 EAT (wb) 5000 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 10 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 101.7 115.2 96.6 96.6 101.7 115.2 83.8 96.6 106.5 112.3 99.9 99.9 96.6 112.3 77.8 93.4 117.8 117.8 111.3 111.3 82.5 98.3 64.1 79.8 128.5 128.5 122.0 122.0 67.4 83.2 49.1 64.9 136.3 136.3 --129.5 54.7 71.2 --52.3 TC SHC TC SHC TC SHC TC SHC TC SHC 75 106.3 92.2 112.5 83.8 123.5 69.2 134.3 53.8 ----- 85 EAT (db) 80 106.3 106.3 112.5 99.5 123.5 85.0 134.3 69.6 142.4 56.8 TC SHC TC SHC TC SHC TC SHC TC SHC 112.9 97.9 116.3 90.2 126.9 73.2 137.5 55.3 ----- 112.9 112.9 116.3 108.2 126.9 91.3 137.5 73.4 145.1 59.0 127.8 127.8 126.2 126.2 126.9 109.4 137.5 91.5 145.1 78.2 108.0 93.6 110.5 87.4 120.9 70.8 131.4 53.1 ----- 108.0 108.0 110.5 105.3 120.9 88.9 131.4 71.1 138.8 56.7 122.3 122.3 123.3 123.3 120.9 107.1 131.4 89.2 138.8 75.8 102.7 89.0 103.8 84.0 114.3 68.1 124.7 50.6 ----- 102.7 102.7 103.8 101.8 114.3 86.2 124.7 68.7 131.7 54.3 116.3 116.3 119.5 119.5 114.3 104.4 124.7 86.7 131.7 73.1 96.8 83.9 97.1 79.8 106.8 65.0 117.2 47.8 ----- 96.8 96.8 97.1 97.1 106.8 83.2 117.2 65.9 123.6 51.5 109.7 109.7 114.3 114.3 106.8 101.3 117.2 83.9 123.6 70.0 TC SHC TC SHC TC SHC TC SHC TC SHC 117.8 102.2 119.1 95.8 129.4 76.9 139.7 56.7 ----- 117.8 117.8 119.1 115.9 129.4 97.3 139.7 76.8 147.0 60.6 133.5 133.5 136.0 136.0 129.4 117.7 139.7 97.0 147.0 81.7 113.0 98.0 113.5 92.8 123.3 74.5 133.5 54.4 ----- 113.0 113.0 113.5 112.6 123.3 95.0 133.5 74.6 140.5 58.4 128.0 128.0 132.5 132.5 123.3 115.4 133.5 94.7 140.5 79.3 107.5 93.3 107.7 88.6 116.5 71.8 126.6 51.9 ----- 107.5 107.5 107.7 107.7 116.5 92.3 126.6 72.1 133.2 55.8 121.8 121.8 126.7 126.7 116.5 112.8 126.6 92.3 133.2 76.5 101.5 88.0 101.6 83.6 108.9 68.8 118.8 49.1 ----- 101.5 101.5 101.6 101.6 108.9 89.3 118.8 69.3 124.9 53.0 115.0 115.0 119.6 119.6 109.8 109.8 118.8 89.5 124.9 73.5 TC SHC TC SHC TC SHC TC SHC TC SHC 121.7 105.6 121.8 100.2 131.3 80.3 141.5 57.9 ----- 121.7 121.7 121.8 121.8 131.3 102.9 141.5 80.0 148.3 62.1 137.9 137.9 143.4 143.4 131.3 125.5 141.5 102.1 148.3 84.9 116.8 101.3 116.9 96.1 125.1 78.0 135.1 55.6 ----- 116.8 116.8 116.9 116.9 125.1 100.7 135.1 77.7 141.8 59.8 132.3 132.3 137.6 137.6 125.1 123.3 135.1 99.9 141.8 82.5 111.2 96.4 111.3 91.6 118.2 75.3 128.0 53.1 ----- 111.2 111.2 111.3 111.3 118.2 98.0 128.0 75.2 134.3 57.3 126.0 126.0 131.0 131.0 120.8 120.8 128.0 97.4 134.3 79.7 105.0 91.0 105.1 86.5 110.5 72.3 120.1 50.3 ----- 105.0 105.0 105.1 105.1 110.5 95.0 120.1 72.4 125.8 54.4 118.9 118.9 123.7 123.7 117.7 117.7 120.1 94.6 125.8 76.6 TC SHC TC SHC TC SHC TC SHC TC SHC 125.0 108.4 125.1 102.9 132.8 83.6 142.8 59.0 ----- 125.0 125.0 125.1 125.1 132.8 108.3 142.8 82.9 149.4 63.4 141.6 141.6 147.2 147.2 133.0 133.0 142.8 106.9 149.4 87.9 120.0 104.0 120.1 98.8 126.5 81.2 136.3 56.7 ----- 120.0 120.0 120.1 120.1 126.5 106.0 136.3 80.7 142.8 61.2 135.9 135.9 141.4 141.4 130.8 130.8 136.3 104.7 142.8 85.5 114.3 99.1 114.4 94.1 119.6 78.6 129.1 54.1 ----- 114.3 114.3 114.4 114.4 119.6 103.4 129.1 78.2 135.1 58.6 129.5 129.5 134.7 134.7 128.2 128.2 129.1 102.2 135.1 82.7 107.9 93.6 108.0 88.9 111.8 75.6 121.1 51.3 ----- 107.9 107.9 108.0 108.0 111.8 100.3 121.1 75.4 126.5 55.6 122.3 122.3 127.2 127.2 125.1 125.1 121.1 99.4 126.5 79.4 580J*12A (RTPF) 58 1-- STAGE COOLING 85 120.5 120.5 115.2 115.2 123.5 100.7 134.3 85.5 142.4 73.3 75 101.7 88.2 106.5 81.0 117.8 66.8 128.5 51.6 ----- Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 47 85 109.4 109.4 109.0 109.0 111.3 95.5 122.0 80.7 129.5 68.8 115 EAT (db) 75 80 91.0 91.0 78.9 91.0 92.7 92.7 74.2 89.7 104.0 104.0 61.0 76.8 114.7 114.7 46.3 62.1 --121.8 --49.7 85 103.1 103.1 105.2 105.2 104.0 92.5 114.7 77.9 121.8 66.2 580J Table 27 – COOLING CAPACITIES Table 28 – COOLING CAPACITIES EAT (wb) 3000 Cfm 62 67 72 76 580J 58 EAT (wb) 3500 Cfm 62 67 72 76 58 EAT (wb) 4000 Cfm 62 67 72 76 58 EAT (wb) 4500 Cfm 62 67 72 76 58 EAT (wb) 5000 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 10 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 102.5 116.2 96.8 96.8 102.5 116.2 83.9 96.8 107.1 113.4 99.7 99.7 97.4 113.4 78.0 93.9 118.4 118.4 111.5 111.5 83.2 99.2 64.3 80.3 129.7 129.7 122.8 122.8 68.1 84.2 49.3 65.4 139 139 --131.9 55.6 72.1 --53.1 TC SHC TC SHC TC SHC TC SHC TC SHC 75 107.6 93.2 113.6 84.6 124.4 69.7 135.8 54.3 ----- 85 EAT (db) 80 107.6 107.6 113.6 100.6 124.4 85.7 135.8 70.4 145.3 57.8 TC SHC TC SHC TC SHC TC SHC TC SHC 114.2 98.9 117.2 91.1 127.8 73.8 139.4 56.0 ----- 114.2 114.2 117.2 109.5 127.8 92.3 139.4 74.6 148.8 60.2 129.4 129.4 127.9 127.9 127.8 110.8 139.4 93.1 148.8 79.5 108.9 94.3 111.0 88.1 121.7 71.3 133.0 53.7 ----- 108.9 108.9 111.0 106.4 121.7 89.8 133.0 72.2 142.2 58.0 123.4 123.4 124.7 124.7 121.7 108.3 133 90.8 142.2 77.1 102.9 89.1 104.0 83.9 114.5 68.4 125.8 51.0 ----- 102.9 102.9 104.0 101.7 114.5 87.0 125.8 69.6 134.9 55.4 116.6 116.6 119.5 119.5 114.5 105.5 125.8 88.2 134.9 74.5 96.3 83.4 96.5 79.3 106.6 65.2 117.9 48.1 ----- 96.3 96.3 96.5 96.5 106.6 83.8 117.9 66.7 126.8 52.7 109.1 109.1 113.7 113.7 106.6 102.3 117.9 85.4 126.8 71.6 TC SHC TC SHC TC SHC TC SHC TC SHC 119.0 103.1 120.3 96.5 130.5 77.7 142.1 57.6 ----- 119.0 119.0 120.3 116.8 130.5 98.6 142.1 78.4 151.4 62.3 134.9 134.9 137.1 137.1 130.5 119.5 142.1 99.3 151.4 83.8 114.0 98.7 114.7 93.0 124.1 75.2 135.5 55.2 ----- 114.0 114.0 114.7 112.9 124.1 96.2 135.5 76.1 144.7 60.0 129.2 129.2 132.8 132.8 124.1 117.2 135.5 97.1 144.7 81.4 108.0 93.6 108.2 88.9 116.8 72.3 128.2 52.5 ----- 108.0 108.0 108.2 108.2 116.8 93.3 128.2 73.6 137.1 57.5 122.4 122.4 127.5 127.5 116.8 114.4 128.2 94.6 137.1 78.8 101.1 87.6 101.3 83.2 108.7 69.1 120.0 49.7 ----- 101.1 101.1 101.3 101.3 108.7 90.1 120.0 70.7 ----- 114.6 114.6 119.3 119.3 111.1 111.1 120.0 91.8 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 123.0 106.6 123.4 100.9 132.6 81.4 144.2 59.0 ----- 123.0 123.0 123.4 122.7 132.6 104.6 144.2 82.1 153.4 64.1 139.5 139.5 144.4 144.4 132.6 127.9 144.2 105.2 153.4 87.8 117.8 102.1 117.9 96.9 126.0 78.9 137.4 56.6 ----- 117.8 117.8 117.9 117.9 126 102.3 137.4 79.8 146.6 61.9 133.6 133.6 139.0 139 126.0 125.7 137.4 103.1 146.6 85.6 111.9 97.0 112.0 92.1 118.7 76.1 129.9 54.0 ----- 111.9 111.9 112.0 112.0 118.7 99.5 129.9 77.3 138.9 59.4 126.9 126.9 132.0 132 122.9 122.9 129.9 100.7 138.9 83 105.3 91.2 105.4 86.6 110.4 72.9 121.6 51.1 ----- 105.3 105.3 105.4 105.4 110.4 96.2 121.6 74.5 ----- 119.3 119.3 124.2 124.2 119.6 119.6 121.6 98 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 126.5 109.6 126.5 104.0 134.2 84.9 145.8 60.3 ----- 126.5 126.5 126.5 126.5 134.2 110.4 145.8 85.6 155.1 65.9 143.3 143.3 149.1 149.1 135.9 135.9 145.8 110.8 155.1 91.5 121.2 105.0 121.3 99.7 127.5 82.4 139.0 57.9 ----- 121.2 121.2 121.3 121.3 127.5 108.1 139.0 83.4 148.2 63.7 137.4 137.4 142.9 142.9 133.8 133.8 139.0 108.9 148.2 89.5 115.1 99.8 115.2 94.7 120.1 79.6 131.3 55.3 ----- 115.1 115.1 115.2 115.2 120.1 105.3 131.3 81.0 ----- 130.5 130.5 135.8 135.8 131.0 131 131.3 106.6 ----- 108.4 93.9 108.5 89.1 111.9 76.4 122.9 52.5 ----- 108.4 108.4 108.5 108.5 111.9 102.0 122.9 78.2 ----- 122.8 122.8 127.8 127.8 127.6 127.6 122.9 104 ----- 580J*12D (RTPF & Novation) 58 2-- STAGE COOLING 85 121.9 121.9 116.5 116.5 124.4 101.7 135.8 86.6 145.3 74.3 75 102.5 88.8 107.1 81.5 118.4 67.1 129.7 52.0 ----- Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 48 85 109.7 109.7 109.8 109.8 111.5 96.3 122.8 81.6 131.9 69.6 115 EAT (db) 75 80 90.5 90.5 78.4 90.5 91.8 91.8 73.7 89.3 103.3 103.3 60.8 76.8 115 115 46.4 62.5 --124.1 --50.4 85 102.6 102.6 104.9 104.9 103.3 92.8 115 78.6 124.1 66.9 2-- STAGE COOLING 10 TONS 580J12 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE AIR ENTERING EVAPORATOR --- CFM 3000/0.04 4000/0.06 5000/0.07 TEMP (F) AIR ENT CONDENSER (Edb) Air Entering Evaporator --- Ewb (F) 72 67 62 72 67 62 72 67 TC 142.85 129.44 116.93 152.09 138.44 125.76 157.99 144.23 75 SHC 58.38 74.88 91.58 67.96 89.45 111.02 76.63 102.94 kW 7.19 6.97 6.79 6.92 7.12 7.35 7.45 7.22 TC 132.33 119.68 107.86 140.92 128.03 116.10 146.41 133.41 85 SHC 48.44 65.56 82.83 57.37 79.50 101.68 65.65 92.58 kW 7.98 7.77 7.58 7.72 7.92 8.14 8.25 8.01 TC 121.41 109.52 98.43 129.35 117.22 106.04 134.43 122.20 95 SHC 38.19 55.92 73.78 46.47 69.22 92.01 54.34 81.92 kW 8.87 8.66 8.48 8.61 8.80 9.03 9.14 8.90 TC 110.04 98.92 88.56 117.27 105.94 95.53 121.88 110.46 105 SHC 27.59 45.94 64.39 35.16 58.57 81.98 42.56 70.82 kW 9.86 9.66 9.48 9.61 9.79 10.02 10.12 9.89 TC 98.09 87.74 78.13 104.62 94.08 84.45 108.76 98.13 115 SHC 16.52 35.47 54.53 23.37 47.44 71.46 30.32 59.25 kW 10.95 10.76 10.60 10.72 10.89 11.10 11.19 10.98 62 132.06 127.93 7.02 121.98 118.12 7.82 111.50 107.96 8.71 100.54 97.40 9.70 89.01 86.31 10.81 580J12 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE AIR ENTERING EVAPORATOR --- Ewb (F) 75 Dry Bulb 75 Dry Bulb 75 Dry Bulb 62.5 Wet Bulb 64 Wet Bulb 65.3 Wet Bulb TEMP (F) AIR ENT (50% Relative) (56% Relative) (60% Relative) CONDENSER (Edb) Air Entering Evaporator --- Cfm 3000 4000 5000 3000 4000 5000 3000 4000 TC 44.78 39.41 31.89 53.22 49.44 43.38 60.56 58.12 80 SHC --- 0.44 --- 0.57 --- 0.69 --- 0.37 --- 0.51 --- 0.61 --- 0.33 --- 0.46 kW 6.96 6.77 6.52 7.26 7.13 6.91 7.54 7.45 TC 45.84 40.46 32.86 54.28 50.51 44.45 61.61 59.19 75 SHC 0.53 0.40 0.29 0.60 0.47 0.37 0.64 0.52 kW 6.77 6.56 6.29 7.11 6.95 6.72 7.41 7.31 TC 46.91 41.48 33.50 55.36 51.59 45.50 62.69 60.28 70 SHC 1.51 1.38 1.27 1.57 1.45 1.35 1.61 1.50 kW 6.54 6.32 6.02 6.90 6.74 6.49 7.23 7.13 TC 48.88 43.42 35.76 57.29 53.56 47.48 64.56 62.16 60 SHC 3.44 3.34 3.24 3.51 3.40 3.31 3.55 3.45 kW 6.45 6.16 6.70 6.93 6.72 6.39 7.38 7.24 TC 50.83 45.28 37.67 59.22 55.52 49.43 66.05 64.03 50 SHC 5.38 5.29 5.20 5.45 5.36 5.28 5.48 5.40 kW 6.46 6.01 6.34 6.98 6.71 6.29 8.15 7.38 TC 52.82 47.29 39.50 61.14 57.48 51.39 68.23 65.88 40 SHC 7.32 7.24 7.20 7.38 7.31 7.24 7.43 7.36 kW 6.29 6.09 6.12 7.05 6.72 6.29 7.78 7.55 5000 53.32 --- 0.56 7.27 54.40 0.42 7.12 55.49 1.40 6.92 57.42 3.37 6.96 59.34 5.33 7.02 61.25 7.29 7.10 NOTE: Perfect Humidity only available on 2---stage RTPF models. LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 49 580J Table 29 – COOLING CAPACITIES Table 30 – COOLING CAPACITIES EAT (wb) 3600 Cfm 62 67 72 76 580J 58 EAT (wb) 4200 Cfm 62 67 72 76 58 EAT (wb) 4800 Cfm 62 67 72 76 58 EAT (wb) 5400 Cfm 62 67 72 76 58 EAT (wb) 6000 Cfm 62 67 72 76 LEGEND: --Cfm EAT(db) EAT(wb) SHC TC ------------- 12.5 TONS AMBIENT TEMPERATURE 95 105 EAT (db) EAT (db) 80 85 75 80 121.7 137.6 115.0 115.0 121.7 137.6 99.9 115.0 131.1 131.1 123.8 123.8 111.2 127.7 91.4 108.0 142.0 142.0 136.2 136.2 93.1 109.2 74.7 91.0 152.4 152.4 147.2 147.2 75.2 91.7 56.8 73.3 160.0 160 --155.1 61.1 80.9 --59.5 TC SHC TC SHC TC SHC TC SHC TC SHC 75 127.6 110.3 136.1 96.6 146.2 78.5 155.9 60.1 ----- 85 EAT (db) 80 127.6 126.6 136.1 112.8 146.2 94.4 155.9 76.6 163.0 62.0 TC SHC TC SHC TC SHC TC SHC TC SHC 132.2 115.0 139.6 102.5 149.5 81.8 159.0 61.4 ----- 132.2 132.2 139.6 120.8 149.5 99.6 159.0 79.6 165.7 64.6 149.5 149.5 139.6 139 149.5 117.4 159.0 97.8 165.7 87.7 128.2 111.5 134.7 100.8 145.4 80.6 155.5 60.2 ----- 128.2 128.2 134.7 119.4 145.4 98.7 155.5 78.5 162.8 63.5 144.9 144.9 138 138 145.4 116.8 155.5 96.8 162.8 86.3 121.9 106.0 128.0 98.1 139.6 78.5 150.3 58.3 ----- TC SHC TC SHC TC SHC TC SHC TC SHC 136.7 118.9 142.2 107.7 152.1 84.8 161.3 62.6 ----- 136.7 136.7 142.2 127.8 152.1 104.3 161.3 82.2 167.7 66.4 154.5 154.5 147.8 147.8 152.1 123.7 161.3 101.9 167.7 91.4 133.0 115.7 137.4 106.2 148.0 83.8 157.8 61.4 ----- 133.0 133.0 137.4 126.7 148 103.8 157.8 81.4 164.9 65 150.3 150.3 147.1 147.1 148 123.7 157.8 101.3 164.9 89.2 TC SHC TC SHC TC SHC TC SHC TC SHC 140.5 122.2 144.3 112.2 154.2 87.6 163.1 63.6 ----- 140.5 140.5 144.3 133.9 154.2 108.6 163.1 84.6 169.3 67.6 158.8 158.8 155.7 155.7 154.2 129.6 163.1 105.6 169.3 93.7 136.9 119 139.6 110.9 150.0 86.8 159.7 62.5 ----- 136.9 136.9 139.6 132.9 150.0 108.5 159.7 83.9 166.5 66.4 TC SHC TC SHC TC SHC TC SHC TC SHC 143.6 124.9 146.1 116.1 155.8 90.1 164.5 64.5 ----- 143.6 143.6 146.1 139.3 155.8 112.6 164.5 86.7 170.6 68.7 162.3 162.3 162.4 162.4 155.8 135 164.5 108.9 170.6 95.8 140.1 121.8 141.7 114.7 151.6 89.6 161.2 63.5 ----- 140.1 140.1 141.7 138.1 151.6 112.8 161.2 86.3 167.8 67.5 580J*14D (RTPF & Novation) 58 2-- STAGE COOLING 85 142.9 142.9 136.1 129.0 146.2 110.3 155.9 93.2 163 81.8 75 121.7 105.8 131.1 94.7 142.0 76.9 152.4 58.7 ----- Do not operate in this region Cubic feet per minute (supply air) Entering air temperature (dry bulb) Entering air temperature (wet bulb) Sensible heat capacity Total capacity 50 85 130 130 124.5 124.5 136.2 107.3 147.2 89.7 155.1 79.3 75 108.3 94.1 114.9 87.3 128.8 71.7 140.1 54.2 ----- 115 EAT (db) 80 108.3 108.3 114.9 103.8 128.8 88.1 140.1 70.6 148.2 57.0 121.9 121.9 128.0 116.8 139.6 96.9 150.3 76.7 157.8 61.5 137.8 137.8 135.6 135.6 139.6 115.2 150.3 95 157.8 83.3 115.0 99.9 119.1 93.9 132.1 75.7 143.1 55.8 ----- 115.0 115.0 119.1 112.6 132.1 94.3 143.1 74.2 150.8 58.9 130.1 130.1 131.2 131.2 132.1 112.8 143.1 92.5 150.8 79.9 127.7 111.0 131.0 103.6 142.2 82.0 152.5 59.7 ----- 127.7 127.7 131.0 124.2 142.2 102.3 152.5 79.7 159.9 63.1 144.3 144.3 144.7 144.7 142.2 122.6 152.5 99.8 159.9 86.4 120.6 104.9 122.8 99.3 134.6 79.4 145.4 57.2 ----- 120.6 120.6 122.8 119.8 134.6 99.9 145.4 77.3 152.8 60.5 136.4 136.4 140.3 140.3 134.6 120.4 145.4 97.5 152.8 83.1 154.7 154.7 155 155 150.0 130.1 159.7 105.4 166.5 91.7 131.8 114.7 133.5 108.1 144.2 85.2 154.3 60.8 ----- 131.8 131.8 133.5 130.2 144.2 107.3 154.3 82.5 161.5 64.5 149 149 152.4 152.4 144.2 129.4 154.3 104.2 161.5 89.2 125.2 108.9 125.8 103.9 136.7 82.8 147.1 58.4 ----- 125.2 125.2 125.8 125.8 136.7 105.1 147.1 80.2 154.2 61.9 141.6 141.6 147.8 147.8 136.7 127.4 147.1 102 154.2 86.1 158.3 158.3 161.5 161.5 151.6 136 161.2 109.1 167.8 94.1 135.1 117.5 135.6 112.1 145.9 88.3 155.8 61.9 ----- 135.1 135.1 135.6 135.6 145.9 112.0 155.8 85.1 162.8 65.7 152.7 152.7 159.2 159.2 145.9 135.8 155.8 108.2 162.8 91.8 128.7 111.9 128.8 106.4 138.3 85.9 148.5 59.6 ----- 128.7 128.7 128.8 128.8 138.3 110.0 148.5 82.9 155.5 63.3 145.5 145.5 151.2 151.2 138.3 134.1 148.5 106.3 155.5 88.8 85 122.6 122.6 120.3 120.3 128.8 104.6 140.1 87.0 148.2 76.3 2-- STAGE COOLING 12.5 TONS 580J14 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN SUBCOOLING MODE AIR ENTERING EVAPORATOR --- CFM 3750/0.02 5000/0.06 6250/0.05 TEMP (F) AIR ENT CONDENSER (Edb) Air Entering Evaporator --- Ewb (F) 72 67 62 72 67 62 72 67 TC 183.66 166.86 151.43 194.90 177.83 162.05 201.97 184.84 75 SHC 79.39 100.52 121.91 91.70 119.42 147.05 102.94 137.00 kW 9.82 9.63 9.46 9.58 9.76 9.96 10.04 9.84 TC 172.71 156.78 142.09 183.32 167.13 152.17 189.98 173.73 85 SHC 69.03 90.92 112.95 80.69 109.17 137.51 91.49 126.33 kW 10.82 10.63 10.45 10.57 10.76 10.96 11.04 10.84 TC 161.37 146.24 132.38 171.36 156.04 141.86 177.62 162.22 95 SHC 58.44 81.04 103.77 69.42 98.67 127.71 79.83 115.45 kW 11.92 11.73 11.56 11.68 11.86 12.05 12.14 11.93 TC 149.57 135.32 122.21 158.89 144.45 131.10 164.74 150.27 105 SHC 47.57 70.92 94.32 57.85 87.91 117.61 67.79 104.26 kW 13.12 12.94 12.77 12.89 13.06 13.24 13.32 13.13 TC 137.22 123.88 111.55 145.85 132.33 119.84 151.27 137.71 115 SHC 36.31 60.47 84.57 45.87 76.77 107.19 55.34 92.66 kW 14.41 14.25 14.10 14.20 14.35 14.53 14.59 14.42 62 170.53 166.71 9.67 160.25 156.65 10.67 149.50 146.15 11.77 138.35 135.30 12.97 126.67 123.98 14.28 580J14 COOLING CAPACITIES, UNIT WITH PERFECT HUMIDITY SYSTEM IN HOT GAS REHEAT MODE AIR ENTERING EVAPORATOR --- Ewb (F) 75 Dry Bulb 75 Dry Bulb 75 Dry Bulb 62.5 Wet Bulb 64 Wet Bulb 65.3 Wet Bulb TEMP (F)AIR ENT (50% Relative) (56% Relative) (60% Relative) CONDENSER(Edb) Air Entering Evaporator --- Cfm 3750 5000 6250 3750 5000 6250 3750 5000 TC 52.42 45.88 36.99 62.64 58.07 51.07 71.56 68.64 80 SHC --- 0.39 --- 0.54 --- 0.67 --- 0.31 --- 0.46 --- 0.58 --- 0.26 --- 0.40 kW 9.65 9.39 9.07 9.97 9.77 9.50 10.25 10.11 TC 53.45 46.63 36.10 63.77 59.11 51.87 72.76 69.80 75 SHC 0.59 0.44 0.30 0.67 0.52 0.40 0.72 0.58 kW 9.09 8.83 8.49 9.39 9.20 8.94 9.67 9.53 TC 54.33 46.91 37.58 64.77 60.01 52.30 73.80 70.80 70 SHC 1.56 1.41 1.29 1.64 1.50 1.38 1.70 1.56 kW 8.81 8.53 8.62 9.15 8.94 8.65 9.46 9.31 TC 55.47 49.48 40.48 66.62 62.07 54.88 75.68 72.76 60 SHC 3.50 3.38 3.27 3.59 3.47 3.36 3.65 3.52 kW 8.36 8.84 8.98 9.88 9.56 9.10 9.83 9.64 TC 58.33 51.72 42.81 68.72 63.93 55.84 77.74 74.77 50 SHC 5.47 5.35 5.24 5.54 5.43 5.32 5.60 5.49 kW 8.98 9.25 9.43 9.33 8.97 8.73 9.55 9.33 TC 60.33 53.69 46.89 70.67 65.93 49.83 79.46 76.62 40 SHC 7.42 7.31 7.22 7.49 7.39 7.23 7.55 7.45 kW 9.16 9.88 9.06 9.50 9.05 9.47 10.31 10.00 6250 63.23 --- 0.52 9.89 64.31 0.47 9.32 65.24 1.45 9.08 67.28 3.42 9.31 69.24 5.39 9.70 71.24 7.37 9.48 NOTE: Perfect Humidity only available on 2---stage RTPF models. LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – total capacity (Btuh) 4.5 x cfm Where: hewb = Enthalpy of air entering evaporator coil hlwb = hewb – 51 580J Table 31 – COOLING CAPACITIES Table 32 – COOLING CAPACITIES 2-- STAGE COOLING 15 TONS Ambient Temperature 75 85 EA (dB) 80 85 75 95 EA (dB) 80 85 75 105 EA (dB) 80 85 75 115 EA (dB) 80 THC SHC THC SHC THC SHC THC SHC THC SHC 156.6 134.7 166.7 122.8 184.1 101.6 200.3 78.7 - 156.6 154.9 166.7 144.9 184.1 123.7 200.3 101.1 211.4 82.2 175.2 175.2 166.9 166.9 184.1 145.7 200.3 123.5 211.4 107.0 149.4 129.8 158.0 118.6 175.6 98.1 192.0 75.5 - 149.4 149.4 158.0 140.6 175.6 120.2 192.0 97.9 203.1 79.3 169.1 169.1 162.6 162.6 175.6 142.3 192.0 120.2 203.1 103.8 141.6 123.0 147.6 113.5 165.6 94.0 182.9 72.1 - 141.6 141.6 147.6 135.3 165.6 116.1 182.9 94.4 193.8 76.0 160.2 160.2 157.2 157.2 165.6 138.2 182.9 116.7 193.8 100.2 133.3 115.7 136.8 107.4 154.5 89.4 172.2 68.2 - 133.3 133.3 136.8 128.8 154.5 111.5 172.2 90.5 183.9 72.6 150.9 150.9 150.3 150.3 154.5 133.6 172.2 112.7 183.9 96.5 THC SHC THC SHC THC SHC THC SHC THC SHC 165.2 143.5 172.3 131.6 189.5 107.2 205.0 80.9 - 165.2 165.2 172.3 156.6 189.5 132.4 205.0 106.1 215.4 85.0 186.9 186.9 181.7 181.7 189.5 157.5 205.0 131.3 215.4 113.0 158.2 137.4 163.4 127.1 180.9 103.8 196.5 77.7 - 158.2 158.2 163.4 152.0 180.9 129.0 196.5 102.9 206.8 82.0 179.0 179.0 176.9 176.9 180.9 154.1 196.5 128.1 206.8 109.8 150.0 130.2 153.1 120.5 170.7 99.9 187.1 74.4 - 150.0 150.0 153.1 144.9 170.7 125.1 187.1 99.5 197.1 78.8 169.7 169.7 169.3 169.3 170.7 150.4 187.1 124.7 197.1 106.4 141.3 122.7 143.4 114.1 159.1 95.3 176.4 70.6 - 141.3 141.3 143.4 137.8 159.1 120.6 176.4 95.8 186.9 75.4 160.0 160.0 161.4 161.4 159.1 145.8 176.4 121.0 186.9 102.8 THC SHC THC SHC THC SHC THC SHC THC SHC 172.7 150.0 176.6 139.6 193.6 112.3 208.4 82.7 - 172.7 172.7 176.6 167.7 193.6 140.3 208.4 110.5 218.2 87.5 195.4 195.4 195.7 195.7 193.6 168.3 208.4 138.3 218.2 118.6 165.5 143.8 168.1 133.2 184.8 108.9 199.6 79.6 - 165.5 165.5 168.1 160.4 184.8 137.0 199.6 107.3 209.5 84.5 187.3 187.3 187.6 187.6 184.8 165.2 199.6 135.1 209.5 115.2 157.1 136.4 158.9 127.1 174.7 105.2 190.2 76.2 - 157.1 157.1 158.9 153.7 174.7 133.5 190.2 104.0 199.5 81.1 177.8 177.8 180.2 180.2 174.7 161.7 190.2 131.8 199.5 111.3 148.1 128.6 148.9 120.7 162.7 100.7 179.5 72.6 - 148.1 148.1 148.9 146.4 162.7 129.0 179.5 100.6 189.0 77.5 167.7 167.7 172.1 172.1 162.7 157.3 179.5 128.5 189.0 107.3 THC SHC THC SHC THC SHC THC SHC THC SHC 178.8 155.3 181.0 144.1 196.8 117.0 211.0 84.3 - 178.8 178.8 181.0 173.9 196.8 147.7 211.0 114.5 220.2 89.5 202.4 202.4 203.6 203.6 196.8 178.4 211.0 144.7 220.2 122.8 171.6 149.0 173.0 139.1 187.9 113.7 202.2 81.2 - 171.6 171.6 173.0 168.3 187.9 144.5 202.2 111.5 211.5 86.4 194.2 194.2 197.5 197.5 187.9 175.4 202.2 141.7 211.5 119.4 163.1 141.6 163.8 133.3 177.7 110.1 192.5 77.9 - 163.1 163.1 163.8 161.7 177.7 141.1 192.5 108.1 201.3 83.0 184.6 184.6 190.1 190.1 177.7 172.2 192.5 138.4 201.3 115.4 153.8 133.5 153.9 126.7 165.5 105.6 181.8 74.4 - 153.8 153.8 153.9 153.9 165.5 136.8 181.8 104.9 190.6 79.4 174.1 174.1 181.1 181.1 167.9 167.9 181.8 135.4 190.6 111.5 THC SHC THC SHC THC SHC THC SHC THC SHC 183.9 159.7 185.1 149.5 199.3 121.3 213.0 85.8 - 183.9 183.9 185.1 181.0 199.3 154.6 213.0 118.2 221.9 91.2 208.2 208.2 212.5 212.5 199.3 187.9 213.0 150.5 221.9 126.5 176.6 153.3 177.1 144.5 190.3 118.1 204.1 82.7 - 176.6 176.6 177.1 175.4 190.3 151.6 204.1 115.2 213.0 88.2 199.8 199.8 206.2 206.2 190.3 185.1 204.1 147.7 213.0 123.1 168.2 146.0 168.3 138.7 180.0 114.4 194.2 79.4 - 168.2 168.2 168.3 168.3 180.0 148.1 194.2 111.9 202.7 84.7 190.3 190.3 197.9 197.9 181.7 181.7 194.2 144.4 202.7 119.2 158.6 137.7 158.7 130.8 167.8 110.1 183.5 76.0 - 158.6 158.6 158.7 158.7 167.8 144.0 183.5 108.8 191.8 81.2 179.5 179.5 186.7 186.7 177.8 177.8 183.5 141.6 191.8 115.3 580J*16D (RTPF) 58 EAT (wb) 4500 Cfm 62 67 72 76 EAT (wb) 5250 Cfm 62 67 72 76 62 EAT (wb) 6000 Cfm 58 67 72 76 62 EAT (wb) 6750 Cfm 58 67 72 76 58 EAT (wb) 62 7500 Cfm 580J 58 67 72 76 LEGEND Edb --Ewb --kW --Idb --Iwb --SHC --TC --- Entering Dry--- Bulb Entering Wet--- Bulb Compressor Motor Power Input Leaving Dry--- Bulb Leaving Wet--- Bulb Sensible Heat Capacity (1000 Btuh) Gross Total Capacity (1000 Btuh) Gross 85 NOTES: 1. Direct interpolation is permissible. Do not extrapolate. 2. The following formulas may be used: sensible capacity (Btuh) 1.10 x cfm tlwb = Wet--- bulb temperature corresponding to enthalpy of air leaving evaporator coil (hlwb) tldb = tedb – hlwb = hewb – 52 total capacity (Btuh) 4.5 x cfm Table 33 – STATIC PRESSURE ADDERS (Factory Options and/or Accessories) PERFECT HUMIDITY CFM (in. wg) 7.5 Tons 8.5 Tons 10 Tons 12.5 Tons 1000 0.04 ------- 2250 0.12 ------- 1250 0.052 0.106 ----- 2500 0.14 0.11 ----- 2750 0.16 0.12 ----- 3---6 TONS 1750 2000 ----0.172 0.21 0.172 0.21 0.112 0.125 1500 0.07 0.138 0.138 --- 3000 0.19 0.13 0.13 --- 3250 0.21 0.15 0.15 --- 3500 0.23 0.17 0.17 0.17 7.5---12.5 TONS 3750 4000 0.26 --0.18 0.20 0.18 0.20 0.18 0.20 2250 ----0.252 0.161 4250 --0.22 0.22 0.22 4500 ----0.24 0.24 2500 ----0.30 0.19 4750 ----0.26 0.26 5000 ----0.28 0.28 2750 ------0.22 5250 ------0.31 3000 ------0.25 5500 ------0.33 5750 ------0.36 6000 ------0.39 580J CFM (in. wg) 3 Tons 4 Tons 5 Tons 6 Tons ECONOMIZER, BAROMETRIC RELIEF AND PE PERFORMANCE Horizontal Economizers RETURN AIR FLOW (CFM) RELIEF FLOW (CFM) 2500 2000 1500 3 -6 Ton 7½ - 12½ Ton 1000 500 6000 Horizontal Economizers 5000 4000 3 - 6 TON 7 1/2 - 12 1/2 Ton 3000 2000 1000 0 0 0.05 0.1 0.15 0.2 0.25 0 0.3 0 RETURN DUCT STATIC PRESSURE (in. wg) 0.1 0.2 0.3 0.4 RETURN DUCT STATIC PRESSURE DROP (in. wg) C08070 C08072 30 Fig. 13 -- Return Air Pressure Drop Horizontal Economizers 25 20 EXHAUST AIRFLOW (cfm) LEAKAGE ACROSS DAMPER (CFM) Fig. 11 -- Barometric Relief Flow Capacity 3 - 6 Ton 7 1/2 - 12 1/2 Ton 15 10 5 Horizontal Power Exhaust 2500 2000 1500 1000 500 0 0 0 0.00 0.10 0.20 0.30 0.40 0.1 0.2 0.3 0.4 0.5 RETURN DUCT STATIC PRESSURE (in. wg) 0.50 STATIC PRESSURE DELTA (in. wg) C08071 C08012 Fig. 12 -- Outdoor Air Damper Leakage Fig. 14 -- Horizontal Power Exhaust Performance 53 Vertical Economizers 2000 1500 3 -6 Ton 7½ - 12½ Ton 1000 500 5000 4000 2 - 6 Ton 3000 (cfm) RELIEF FLOW (CFM) EXHAUST AIRFLOW Vertical Power Exhaust 2500 7.5 - 15 Ton 2000 1000 0 0 0 0 0.05 0.1 0.15 0.2 0.25 0.1 0.2 0.3 0.4 0.5 RETURN DUCT STATIC PRESSURE (in. wg) 0.3 RETURN DUCT STATIC PRESSURE (in. wg) 101125 Fig. 18 -- Vertical Power Exhaust Performance C08073 Fig. 15 -- Barometric Relief Flow Capacity RELIEF FLOW (CFM) LEAKAGE ACROSS DAMPER (CFM) 30 Vertical Economizers 25 20 3 - 6 Ton 7 1/2 - 12 1/2 Ton 15 10 Horizontal Economizers 2000 1500 15 -Ton 1000 500 5 0 0 0.00 0 0.10 0.20 0.30 0.40 0.05 0.50 0.1 0.15 0.2 0.25 0.3 RETURN DUCT STATIC PRESSURE (in. wg) STATIC PRESSURE DELTA (in. wg) C101120 Fig. 19 -- Barometric Relief Flow--Horizontal 15 Ton C08074 6000 RETURN AIR FLOW (CFM) Fig. 16 -- Outdoor Air Damper Leakage Vertical Economizers 5000 4000 3 - 6 TON 7 1/2 - 12 1/2 Ton 3000 Horizontal Economizers 6000 5000 4000 15 -Ton 3000 2000 1000 2000 0 0 1000 0.1 0.2 0.3 0.4 RETURN DUCT STATIC PRESSURE DROP (in. wg) 0 0 0.1 0.2 0.3 0.4 C101121 Fig. 20 -- Return Air Pressure Drop--Horizontal 15 Ton RETURN DUCT STATIC PRESSURE DROP (in. wg) C08075 Fig. 17 -- Return Air Pressure Drop 2500 RELIEF FLOW (CFM) RETURN AIR FLOW (CFM) 580J 2500 Vertical Economizers 2000 1500 15 -Ton 1000 500 0 0 0.05 0.1 0.15 0.2 0.25 0.3 RETURN DUCT STATIC PRESSURE (in. wg) C101122 Fig. 21 -- Barometric Relief Flow--Vertical 15 Ton 54 2000 FLOW (cfm) RETURN AIR FLOW (CFM) 2500 Vertical Economizers 6000 5000 4000 15-Ton 3000 1500 3-15 Ton 1000 500 2000 0 0 1000 0 0.1 0.2 0.3 0.4 0.5 STATIC PRESSURE (in. wg) 0 0.1 0.2 0.3 0.4 C101124 RETURN DUCT STATIC PRESSURE DROP (in. wg) Fig. 23 -- Horizontal Power Exhaust Performance C101123 Fig. 22 -- Return Air Pressure Drop--Vertical 15 Tons 1. Interpolation is permissible. Do not extrapolate. 2. External static pressure is the static pressure difference between the return duct and the supply duct plus the static pressure caused by any FIOPs or accessories. 3. Tabular data accounts for pressure loss due to clean filters, unit casing, and wet coils. Factory options and accessories may add static pressure losses, as shown in the tables above. Selection software is available, through your salesperson, to help you select the best motor/drive combination for your application. 4. The Fan Performance tables offer motor/drive recommendations. In cases when two motor/drive combinations would work, Bryant recommended the lower horsepower option. 5. For information on the electrical properties of Bryant motors, please see the Electrical information section of this book. 6. For more information on the performance limits of Bryant motors, see the application data section of this book. 7. The EPACT (Energy Policy Act of 1992) regulates energy requirements for specific types of indoor fan motors. Motors regulated by EPACT include any general purpose, T-- frame (three-- digit, 143 and larger), single-- speed, foot mounted, polyphase, squirrel cage induction motors of NEMA (National Electrical Manufacturers Association) design A and B, manufactured for use in the United States. Ranging from 1 to 200 Hp, these continuous-- duty motors operate on 230 and 460 volt, 60 Hz power. If a motor does not fit into these specifications, the motor does not have to be replaced by an EPACT compliant energy efficient motor. Variable speed motors are exempt from EPACT compliance requirements. Therefore, the indoor fan motors for Bryant 580J04-- 16 units are exempt from these requirements. 55 580J General fan performance notes: FAN PERFORMANCE Table 34 – 580J**04 CFM 580J 900 975 1050 1125 1200 1275 1350 1425 1500 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 1 PHASE 0.2 RPM BHP Field Supplied Drive1 553 0.14 575 0.16 597 0.18 620 0.21 643 0.23 667 0.27 691 0.30 715 0.34 740 0.38 1.2 RPM BHP 1019 1036 1053 1071 1089 1107 1126 1144 1163 0.64 0.69 0.74 0.79 0.84 0.90 0.96 1.03 1.10 RPM 681 700 720 741 762 783 805 827 849 3 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 0.22 782 0.32 870 0.42 948 0.25 801 0.35 888 0.46 965 0.28 820 0.38 906 0.49 983 0.31 839 0.42 925 0.54 1001 0.34 859 0.46 944 0.58 1020 0.38 879 0.50 963 0.63 1038 0.42 900 0.55 983 0.68 1057 0.47 920 0.60 1002 0.74 1076 0.52 941 0.66 1023 0.80 1096 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option Field Supplied Drive2 1084 0.76 1146 0.89 1203 1.02 1258 1101 0.81 1162 0.94 1219 1.08 --1118 0.86 1179 1.00 1236 1.14 --1135 0.92 1196 1.06 1253 1.20 --1153 0.98 1213 1.12 ------1171 1.04 1231 1.19 ------1189 1.11 ----------1208 1.18 ------------------------- BHP 0.53 0.57 0.61 0.66 0.71 0.76 0.82 0.88 0.95 BHP 1.16 ----------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AG006) and belt (part no. KR30AE039). 2. Recommend using field supplied motor pulley (part no. KR11HY161) and belt (part no. KR30AE035). Table 35 – 580J**04 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 1 PHASE 0.2 RPM BHP Field Supplied Drive1 567 0.15 591 0.17 615 0.20 641 0.23 666 0.26 693 0.29 719 0.33 746 0.38 773 0.42 1.2 RPM BHP 1016 1034 1053 1073 1093 1113 1133 1154 1175 0.51 0.57 0.63 0.70 0.77 0.85 0.92 1.01 1.09 3 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 688 0.22 786 0.30 871 0.37 947 710 0.26 807 0.34 891 0.42 966 732 0.29 828 0.38 911 0.47 985 755 0.33 849 0.42 931 0.52 1005 778 0.37 871 0.47 952 0.57 1025 802 0.41 893 0.53 974 0.63 1046 826 0.46 916 0.58 995 0.70 1067 850 0.51 939 0.64 1017 0.76 1088 875 0.57 963 0.70 1040 0.84 1110 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option Field Supplied Drive2 1080 0.57 1139 0.64 1195 0.71 1249 1098 0.64 1157 0.72 1213 0.79 1266 1116 0.71 1176 0.79 1231 0.87 1284 1135 0.79 1194 0.87 1250 0.96 1302 1155 0.87 1213 0.96 1268 1.05 1321 1174 0.95 1232 1.05 1287 1.15 --1194 1.03 1252 1.14 ------1215 1.12 ------------------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AG006) and belt (part no. KR30AE039). 2. Recommend using field supplied motor pulley (part no. KR11HY161) and belt (part no. KR30AE035). 56 BHP 0.44 0.49 0.55 0.61 0.67 0.74 0.81 0.89 0.96 BHP 0.77 0.86 0.95 1.04 1.14 --------- FAN PERFORMANCE (cont.) CFM 900 975 1050 1125 1200 1275 1350 1425 1500 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 3 PHASE 0.2 RPM BHP Field Supplied Drive1 553 0.14 575 0.16 597 0.18 620 0.21 643 0.23 667 0.27 691 0.30 715 0.34 740 0.38 1.2 RPM BHP 1019 1036 1053 1071 1089 1107 1126 1144 1163 0.64 0.69 0.74 0.79 0.84 0.90 0.96 1.03 1.10 3 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 681 0.22 782 0.32 870 0.42 948 700 0.25 801 0.35 888 0.46 965 720 0.28 820 0.38 906 0.49 983 741 0.31 839 0.42 925 0.54 1001 762 0.34 859 0.46 944 0.58 1020 783 0.38 879 0.50 963 0.63 1038 805 0.42 900 0.55 983 0.68 1057 827 0.47 920 0.60 1002 0.74 1076 849 0.52 941 0.66 1023 0.80 1096 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 1084 0.76 1146 0.89 1203 1.02 1258 1101 0.81 1162 0.94 1219 1.08 1274 1118 0.86 1179 1.00 1236 1.14 1290 1135 0.92 1196 1.06 1253 1.20 1307 1153 0.98 1213 1.12 1270 1.27 1324 1171 1.04 1231 1.19 1287 1.34 1341 1189 1.11 1249 1.26 1305 1.42 1358 1208 1.18 1267 1.34 1323 1.50 1376 1226 1.25 1285 1.41 1341 1.58 1394 BHP 0.53 0.57 0.61 0.66 0.71 0.76 0.82 0.88 0.95 BHP 1.16 1.22 1.28 1.35 1.42 1.50 1.58 1.66 1.75 NOTE: For more information, see General Fan Performance Notes. 1. Recommend using field supplied drive (part no. KR11AG006) and belt (part no. KR30AE039) Table 37 – 580J**04 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 CFM 900 975 1050 1125 1200 1275 1350 1425 1500 3 PHASE 0.2 RPM BHP Field Supplied Drive1 567 0.15 591 0.17 615 0.20 641 0.23 666 0.26 693 0.29 719 0.33 746 0.38 773 0.42 1.2 RPM BHP 1016 1034 1053 1073 1093 1113 1133 1154 1175 0.51 0.57 0.63 0.70 0.77 0.85 0.92 1.01 1.09 3 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 688 0.22 786 0.30 871 0.37 947 710 0.26 807 0.34 891 0.42 966 732 0.29 828 0.38 911 0.47 985 755 0.33 849 0.42 931 0.52 1005 778 0.37 871 0.47 952 0.57 1025 802 0.41 893 0.53 974 0.63 1046 826 0.46 916 0.58 995 0.70 1067 850 0.51 939 0.64 1017 0.76 1088 875 0.57 963 0.70 1040 0.84 1110 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 1080 0.57 1139 0.64 1195 0.71 1249 1098 0.64 1157 0.72 1213 0.79 1266 1116 0.71 0.79 1231 0.87 1284 1176 1135 0.79 1194 0.87 1250 0.96 1302 1155 0.87 1213 0.96 1268 1.05 1321 1174 0.95 1232 1.05 1287 1.15 1339 1194 1.03 1252 1.14 1307 1.25 1358 1215 1.12 1272 1.24 1326 1.35 1378 1235 1.22 1292 1.34 1346 1.46 1397 NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AG006) and belt (part no. KR30AE039). 57 BHP 0.44 0.49 0.55 0.61 0.67 0.74 0.81 0.89 0.96 BHP 0.77 0.86 0.95 1.04 1.14 1.25 1.35 1.46 1.58 580J Table 36 – 580J**04 FAN PERFORMANCE (cont.) Table 38 – 580J**05 CFM 580J 1200 1300 1400 1500 1600 1700 1800 1900 2000 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 1 PHASE 4 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM BHP RPM BHP Standard Static Option Medium Static Option 0.23 762 0.34 859 0.46 944 0.58 0.28 790 0.40 886 0.52 969 0.65 0.33 819 0.45 913 0.58 996 0.72 0.38 849 0.52 941 0.66 1023 0.80 0.45 879 0.59 970 0.73 1050 0.88 0.52 910 0.67 999 0.82 1078 0.98 0.59 942 0.75 1029 0.91 1106 1.08 0.68 974 0.85 1059 1.02 1135 1.19 0.77 1006 0.95 1090 1.13 1165 1.31 0.2 RPM 643 675 707 740 773 807 841 875 910 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM BHP RPM BHP Medium Static Option Field Supplied Drive1 0.84 1153 0.98 1213 1.12 ----0.92 1177 1.06 --------1.01 1201 1.15 --------1.10 ------------1.20 --------------------------------------------------------------------- 1.0 RPM BHP 1020 1044 1070 1096 1123 1150 1177 1205 1234 0.71 0.78 0.86 0.95 1.04 1.14 1.25 1.37 1.49 1.2 RPM 1089 1113 1138 1163 1189 --------- 2.0 RPM BHP ------------------- ------------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied motor pulley (part no. KR11HY161) and belt (part no. KR30AE035). Table 39 – 580J**05 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 1 PHASE 4 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM BHP RPM BHP Standard Static Option Medium Static Option 0.26 778 0.37 871 0.47 952 0.57 0.31 810 0.43 901 0.54 981 0.65 0.36 842 0.49 931 0.62 1010 0.74 0.42 875 0.57 963 0.70 1040 0.84 0.49 909 0.65 994 0.79 1070 0.94 0.57 943 0.73 1027 0.89 1101 1.05 0.66 978 0.83 1060 1.00 1133 1.16 0.75 1014 0.94 1093 1.11 1165 1.29 0.85 1049 1.05 1127 1.24 1198 1.42 0.2 RPM 666 701 737 773 810 847 885 923 962 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM BHP RPM BHP Medium Static Option Field Supplied Drive1 0.77 1155 0.87 1213 0.96 1268 1.05 0.87 1181 0.98 1239 1.08 1294 1.18 0.98 1208 1.09 --------1.09 ----------------------------------------------------------------------------------- 1.0 RPM BHP 1025 1053 1081 1110 1140 1170 1200 1231 1263 0.67 0.76 0.86 0.96 1.08 1.20 1.32 1.46 1.61 1.2 RPM 1093 1119 1147 1175 ----------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied motor pulley (part no. KR11HY161) and belt (part no. KR30AE035). 58 2.0 RPM BHP 1321 ----------------- 1.14 ----------------- FAN PERFORMANCE (cont.) CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 3 PHASE 4 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM BHP RPM BHP Standard Static Option Medium Static Option 0.23 762 0.34 859 0.46 944 0.58 0.28 790 0.40 886 0.52 969 0.65 0.33 819 0.45 913 0.58 996 0.72 0.38 849 0.52 941 0.66 1023 0.80 0.45 879 0.59 970 0.73 1050 0.88 0.52 910 0.67 999 0.82 1078 0.98 0.59 942 0.75 1029 0.91 1106 1.08 0.68 974 0.85 1059 1.02 1135 1.19 0.77 1006 0.95 1090 1.13 1165 1.31 0.2 RPM 643 675 707 740 773 807 841 875 910 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 0.84 1153 0.98 1213 1.12 1270 1.27 0.92 1177 1.06 1237 1.21 1293 1.36 1.01 1201 1.15 1261 1.31 1317 1.47 1.10 1226 1.25 1285 1.41 1341 1.58 1.20 1252 1.36 1310 1.53 1365 1.70 1.31 1277 1.48 1335 1.65 1390 1.83 1.42 1303 1.60 1361 1.78 1415 1.96 1.55 1330 1.73 1387 1.92 1441 2.11 1.68 1357 1.87 1414 2.07 1467 2.26 1.0 RPM BHP 1020 1044 1070 1096 1123 1150 1177 1205 1234 0.71 0.78 0.86 0.95 1.04 1.14 1.25 1.37 1.49 1.2 RPM 1089 1113 1138 1163 1189 1216 1242 1270 1297 2.0 RPM BHP 1324 1347 1370 1394 1418 1442 1467 1493 --- 1.42 1.52 1.63 1.75 1.87 2.01 2.15 2.30 --- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ506), motor pulley (part no. KR11HY181) and belt (part no. KR30AE041). Table 41 – 580J**05 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 CFM 1200 1300 1400 1500 1600 1700 1800 1900 2000 3 PHASE 4 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM BHP RPM BHP Standard Static Option Medium Static Option 0.26 778 0.37 871 0.47 952 0.57 0.31 810 0.43 901 0.54 981 0.65 0.36 842 0.49 931 0.62 1010 0.74 0.42 875 0.57 963 0.70 1040 0.84 0.49 909 0.65 994 0.79 1070 0.94 0.57 943 0.73 1027 0.89 1101 1.05 0.66 978 0.83 1060 1.00 1133 1.16 0.75 1014 0.94 1093 1.11 1165 1.29 0.85 1049 1.05 1127 1.24 1198 1.42 0.2 RPM 666 701 737 773 810 847 885 923 962 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 0.77 1155 0.87 1213 0.96 1268 1.05 0.87 1181 0.98 1239 1.08 1294 1.18 0.98 1208 1.09 1265 1.21 1320 1.32 1.09 1235 1.22 1292 1.34 1346 1.46 1.21 1263 1.35 1320 1.48 1373 1.61 1.34 1292 1.49 1348 1.63 1401 1.77 1.48 1321 1.64 1376 1.79 1428 1.94 1.63 1350 1.79 1405 1.96 1457 2.12 1.79 1380 1.96 1434 2.13 1486 2.31 1.0 RPM BHP 1025 1053 1081 1110 1140 1170 1200 1231 1263 0.67 0.76 0.86 0.96 1.08 1.20 1.32 1.46 1.61 1.2 RPM 1093 1119 1147 1175 1204 1233 1262 1293 1323 2.0 RPM BHP 1321 1346 1371 1397 1424 1451 1479 1506 --- 1.14 1.28 1.43 1.58 1.74 1.91 2.09 2.28 --- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ506), motor pulley (part no. KR11HY181) and belt (part no. KR30AE041). 59 580J Table 40 – 580J**05 FAN PERFORMANCE (cont.) Table 42 – 580J**06 CFM 580J 1500 1625 1750 1875 2000 2125 2250 2375 2500 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 1 PHASE 0.2 RPM BHP RPM 800 849 899 950 1001 1053 1106 1159 --- 0.39 0.48 0.59 0.70 0.84 0.99 1.16 1.34 --- 904 947 992 1038 1085 1133 1182 1231 --- 1.2 RPM BHP RPM 1247 1276 1308 1342 ----------- 0.98 1.10 1.22 1.37 ----------- 1320 1348 1377 ------------- 5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.49 999 0.60 1087 0.59 1038 0.70 1122 0.70 1078 0.82 1159 0.82 1120 0.95 1198 0.96 1163 1.09 1238 1.12 1208 1.26 1280 1.29 1254 1.44 --1.49 --------------- 1.0 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM Medium Static Option 1.13 1390 1.28 1457 1.24 1416 1.40 --1.38 ------------------------------------------------------- BHP RPM BHP 0.72 0.83 0.95 1.08 1.23 1.40 ------- 1169 1201 1235 1271 1309 --------- 0.85 0.96 1.08 1.22 1.38 --------- BHP RPM BHP 1.44 ----------------- ------------------- ------------------- 2.0 NOTE: For more information, see General Fan Performance Notes. Table 43 – 580J**06 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 1 PHASE 0.2 RPM BHP RPM 848 897 947 997 1048 1100 1152 1205 --- 0.42 0.51 0.61 0.72 0.85 1.00 1.16 1.34 --- 968 1013 1059 1105 1153 1201 1250 ----- 1.2 RPM BHP 1312 1350 1390 ------------- 1.07 1.21 1.36 ------------- 5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.55 1069 0.68 1158 0.65 1111 0.79 1198 0.76 1155 0.91 1240 0.89 1199 1.05 1283 1.03 1244 1.20 1326 1.19 1290 1.37 --1.36 ----------------------- BHP 0.80 0.93 1.06 1.21 1.37 --------- 1.0 RPM BHP Medium Static Option 1238 0.94 1277 1.07 1318 1.21 1359 1.37 --------------------- AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option Field---Supplied Drive1 1380 1.20 1445 1.34 1506 1.48 --1418 1.35 1482 1.50 --------------------------------------------------------------------------------------------------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied motor pulley (part no. KR11HY171) and belt (part no. KR30AE039). 60 BHP ------------------- FAN PERFORMANCE (cont.) CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 3 PHASE 0.2 RPM BHP RPM 800 849 899 950 1001 1053 1106 1159 1212 0.39 0.48 0.59 0.70 0.84 0.99 1.16 1.34 1.55 904 947 992 1038 1085 1133 1182 1231 1281 1.2 RPM BHP RPM 1247 1276 1308 1342 1377 1414 1452 1492 1533 0.98 1.10 1.22 1.37 1.53 1.71 1.91 2.12 2.36 1320 1348 1377 1409 1442 1477 1514 1551 1591 5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.49 999 0.60 1087 0.59 1038 0.70 1122 0.70 1078 0.82 1159 0.82 1120 0.95 1198 0.96 1163 1.09 1238 1.12 1208 1.26 1280 1.29 1254 1.44 1323 1.49 1300 1.64 1367 1.70 1348 1.86 1412 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM Medium Static Option 1.13 1390 1.28 1457 1.24 1416 1.40 1481 1.38 1444 1.53 1507 1.52 1473 1.69 1536 1.69 1505 1.86 1565 1.87 1538 2.04 1597 2.08 1573 2.25 1630 2.30 1609 2.48 1665 2.54 1647 2.73 --- 1.0 BHP RPM BHP 0.72 0.83 0.95 1.08 1.23 1.40 1.59 1.80 2.02 1169 1201 1235 1271 1309 1348 1389 1430 1473 0.85 0.96 1.08 1.22 1.38 1.55 1.74 1.96 2.19 BHP 1.44 1.56 1.70 1.86 2.03 2.22 2.43 2.66 --- 2.0 RPM BHP High Static Option 1522 1.61 1544 1.73 1569 1.87 1596 2.03 1624 2.21 1654 2.40 1686 2.62 1719 2.85 ----- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ506), motor pulley (part no. KR11HY191) and belt (part no. KR30AE042). Table 45 – 580J**06 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 CFM 1500 1625 1750 1875 2000 2125 2250 2375 2500 3 PHASE 0.2 RPM BHP 848 897 947 997 1048 1100 1152 1205 1258 0.42 0.51 0.61 0.72 0.85 1.00 1.16 1.34 1.54 1.2 RPM BHP 1312 1350 1390 1430 1471 1513 1555 1598 1642 1.07 1.21 1.36 1.53 1.72 1.92 2.13 2.37 2.63 5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 968 0.55 1069 0.68 1158 0.80 1238 1013 0.65 1111 0.79 1198 0.93 1277 1059 0.76 1155 0.91 1240 1.06 1318 1105 0.89 1.05 1283 1.21 1359 1199 1153 1.03 1244 1.20 1326 1.37 1401 1201 1.19 1290 1.37 1370 1.55 1444 1250 1.36 1336 1.55 1415 1.75 1487 1299 1.55 1384 1.76 1460 1.96 1532 1349 1.76 1431 1.98 1506 2.20 1576 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 1380 1.20 1445 1.34 1506 1.48 1564 1418 1.35 1482 1.50 1542 1.64 1600 1457 1.51 1520 1.67 1580 1.83 1637 1496 1.69 1559 1.86 1618 2.02 1675 1536 1.89 1598 2.06 1657 2.24 1713 1577 2.10 1638 2.28 1696 2.47 1752 1619 2.33 1679 2.52 1736 2.72 --1661 2.57 1720 2.78 ------1704 2.84 ----------- BHP 0.94 1.07 1.21 1.37 1.54 1.73 1.94 2.17 2.41 BHP 1.62 1.79 1.98 2.19 2.41 2.65 ------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ506), motor pulley (part no. KR11HY191) and belt (part no. KR30AE042). 61 580J Table 44 – 580J**06 FAN PERFORMANCE (cont.) Table 46 – 580J**07 CFM 580J 1800 1950 2100 2250 2400 2550 2700 2850 3000 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 3 PHASE 0.2 RPM BHP Field Supplied Drive1 913 0.64 972 0.78 1032 0.95 1093 1.14 1155 1.36 1217 1.60 1280 1.87 1343 2.17 1406 2.50 RPM 1010 1065 1120 1177 1234 1293 1352 1412 1472 6 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.80 1098 0.98 1178 0.96 1148 1.14 1226 1.14 1200 1.33 1275 1.34 1254 1.55 1325 1.57 1308 1.78 1377 1.82 1363 2.05 1430 2.10 1420 2.34 1484 2.42 1477 2.67 1539 2.76 1535 3.03 1595 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 1.56 1388 1.77 1451 1.98 1510 1.75 1430 1.97 1491 2.20 1550 1.97 1473 2.20 1533 2.43 1590 2.21 1518 2.45 1576 2.69 1632 2.48 1564 2.73 1621 2.98 1676 2.78 1612 3.03 1667 3.30 1721 3.10 1660 3.37 1715 3.64 --3.46 ----------------------- 1.0 BHP RPM BHP 1.16 1.34 1.54 1.76 2.01 2.28 2.59 2.93 3.29 1252 1298 1345 1393 1443 1494 1546 1599 1653 1.35 1.54 1.75 1.98 2.24 2.53 2.84 3.19 3.57 1.2 RPM 1322 1366 1411 1457 1505 1554 1604 1656 --- BHP 2.21 2.43 2.67 2.94 3.24 3.57 ------- 2.0 RPM BHP High Static Option 1568 2.44 1606 2.67 1645 2.92 1686 3.20 1729 3.51 ----------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field --- supplied drive is required. 1. Recommend using field --- supplied fan pulley (part no. KR11AZ406), motor pulley (part no. KR11HY151) and belt (part no. KR29AF035). Table 47 – 580J**07 CFM 1800 1950 2100 2250 2400 2550 2700 2850 3000 3 PHASE 0.2 RPM BHP Field---Supplied Drive1 967 0.63 1029 0.77 1091 0.93 1154 1.11 1218 1.32 1283 1.55 1348 1.80 1414 2.09 1479 2.40 RPM 1075 1132 1189 1248 1308 1369 1431 1493 1556 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.80 1170 0.97 1255 0.96 1223 1.14 1306 1.14 1278 1.33 1358 1.33 1333 1.55 1411 1.55 1390 1.78 1466 1.80 1448 2.05 1521 2.07 1507 2.33 1578 2.37 1566 2.65 1636 2.70 1627 3.00 1694 6 TON VERTICAL SUPPLY 1.0 BHP RPM BHP 1.13 1.32 1.52 1.75 2.01 2.29 2.59 2.92 3.29 1333 1382 1433 1484 1537 1590 1645 1701 1757 1.28 1.49 1.71 1.96 2.23 2.52 2.84 3.19 3.57 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 1800 1406 1.43 1475 1.58 1540 1.72 1601 1.87 1660 2.00 1950 1454 1.65 1521 1.82 1585 1.98 1645 2.13 1703 2.29 2100 1502 1.89 1568 2.07 1631 2.25 1690 2.42 1747 2.59 2250 1552 2.15 1617 2.35 1678 2.54 1737 2.73 1793 2.922 2400 1603 2.44 1666 2.65 1727 2.86 1784 3.06 1839 3.26 2550 1655 2.75 1717 2.98 1776 3.20 3.42 1887 3.64 1833 2700 1709 3.09 1769 3.33 1827 3.57 --------2850 1763 3.45 ----------------3000 --------------------NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ406), motor pulley (part no. KR11HY151) and belt (part no. KR29AF035). 2. Recommend using field supplied fan pulley (part no. KR11AZ506), motor pulley (part no. KR11HY191) and belt (part no. KR29AF042). 1.2 62 FAN PERFORMANCE (cont.) CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 3 PHASE 0.2 RPM BHP RPM 505 533 562 591 621 652 682 713 745 0.52 0.62 0.74 0.88 1.03 1.21 1.40 1.61 1.85 586 610 635 661 688 715 743 772 801 1.2 RPM BHP 838 854 872 890 910 930 951 973 996 1.81 1.96 2.12 2.31 2.51 2.74 2.99 3.26 3.55 7.5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.73 657 0.97 722 0.85 679 1.09 742 0.98 701 1.23 762 1.13 725 1.39 783 1.29 749 1.57 806 1.48 774 1.77 829 1.68 800 1.98 853 1.91 826 2.22 878 2.15 853 2.48 903 BHP 1.22 1.36 1.51 1.68 1.87 2.07 2.30 2.55 2.82 1.0 RPM BHP Medium Static Option 782 1.50 800 1.65 819 1.81 839 1.98 859 2.18 881 2.40 903 2.63 927 2.89 951 3.18 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 891 2.12 941 2.46 988 2.82 1033 3.19 906 2.28 955 2.63 1001 2.99 1046 3.37 922 2.46 970 2.81 1016 3.17 1060 3.56 940 2.65 986 3.01 1031 3.38 1074 3.77 958 2.86 1004 3.23 1048 3.61 1090 4.01 977 3.10 1022 3.47 1065 3.86 1107 4.261 997 3.35 1041 3.74 1083 4.13 1124 4.54 1018 3.63 1061 4.02 1103 4.43 ----1040 3.93 1082 4.34 --------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AZ002) and belt (part no. KR29AF054). Table 49 – 580J**08 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 CFM 2250 2438 2625 2813 3000 3188 3375 3563 3750 3 PHASE 0.2 RPM BHP RPM 513 541 570 600 629 660 690 721 752 0.54 0.65 0.77 0.91 1.07 1.25 1.45 1.67 1.91 595 620 645 672 699 726 754 783 812 1.2 RPM BHP 839 858 878 899 920 942 964 988 1011 1.86 2.02 2.20 2.40 2.62 2.86 3.12 3.41 3.71 7.5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.76 665 1.01 728 0.89 688 1.14 750 1.02 712 1.29 772 1.18 736 1.46 794 1.35 761 1.64 818 1.54 787 1.85 842 1.75 813 2.07 867 1.98 840 2.32 892 2.24 867 2.59 918 BHP 1.27 1.42 1.58 1.76 1.95 2.17 2.41 2.67 2.95 1.0 RPM BHP Medium Static Option 786 1.56 806 1.71 827 1.88 848 2.07 871 2.28 894 2.51 917 2.76 941 3.03 966 3.32 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 889 2.18 935 2.52 980 2.87 1022 3.23 907 2.35 953 2.70 997 3.06 1039 3.43 926 2.54 972 2.89 1015 3.26 1056 3.64 946 2.75 991 3.11 1033 3.49 1074 3.88 966 2.98 1010 3.35 1052 3.74 1093 4.14 987 3.23 1031 3.61 1072 4.01 1112 4.421 1009 3.50 1052 3.89 1093 4.30 ----1032 3.80 1074 4.20 1114 4.61 ----1054 4.11 1096 4.53 --------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field --- supplied drive is required. 1. Recommend using field --- supplied fan pulley (part no. KR11AZ002) and belt (part no. KR29AF054). 63 580J Table 48 – 580J**08 FAN PERFORMANCE (cont.) Table 50 – 580J**09 CFM 580J 2550 2763 2975 3188 3400 3613 3825 4038 4250 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 3 PHASE 0.2 RPM BHP Field---Supplied Drive1 497 0.48 524 0.58 551 0.70 580 0.84 609 1.00 638 1.17 668 1.37 698 1.59 728 1.83 1.2 RPM BHP 833 849 865 883 902 921 941 963 984 1.21 1.36 1.52 1.70 1.90 2.13 2.37 2.63 2.92 RPM 579 602 626 651 677 703 730 758 786 8.5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.61 651 0.75 717 0.72 671 0.87 735 0.86 693 1.01 754 1.00 716 1.17 775 1.17 739 1.35 797 1.35 763 1.54 819 1.56 788 1.76 842 1.79 813 2.00 866 2.04 839 2.26 890 BHP 0.90 1.03 1.18 1.34 1.53 1.73 1.96 2.20 2.47 1.0 RPM BHP Medium Static Option 777 1.05 794 1.19 812 1.35 831 1.52 851 1.71 871 1.93 893 2.16 915 2.42 938 2.70 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 886 1.38 936 1.56 984 1.74 1029 1.93 900 1.53 950 1.72 996 1.90 1041 2.10 916 1.70 964 1.89 1010 2.09 1054 2.29 933 1.89 980 2.09 1025 2.29 1068 2.50 950 2.10 996 2.30 1041 2.51 1083 2.73 969 2.33 1014 2.54 1057 2.76 1099 2.982 988 2.58 1032 2.80 1075 3.02 1116 3.25 1008 2.86 1051 3.08 1093 3.31 1133 3.55 1029 3.15 1071 3.39 1112 3.63 1152 3.87 NOTE: For more information, see General Fan Performance Notes. Boldface indicates field --- supplied drive is required. 1. Recommend using field --- supplied fan pulley (part no. KR11AK012) and belt (part no. KR29AF055). 2. Recommend using field --- supplied motor pulley (part no. KR11HY310), fan pulley (part no. KR11AZ002) and belt (part no. KR29AF054). Table 51 – 580J**09 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 CFM 2550 2763 2975 3188 3400 3613 3825 4038 4250 3 PHASE 0.2 RPM BHP RPM 526 557 588 621 653 687 720 754 788 0.51 0.62 0.75 0.90 1.06 1.25 1.45 1.69 1.94 600 627 655 684 714 744 775 807 839 1.2 RPM BHP 836 855 875 897 919 943 967 992 1018 1.20 1.37 1.56 1.77 1.99 2.24 2.51 2.80 3.11 8.5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.65 666 0.79 727 0.77 690 0.92 749 0.91 716 1.08 772 1.07 743 1.25 797 1.25 770 1.44 822 1.45 798 1.65 849 1.67 827 1.88 876 1.91 856 2.13 904 2.17 886 2.41 932 BHP 0.93 1.08 1.24 1.42 1.62 1.84 2.09 2.35 2.64 1.0 RPM BHP Medium Static Option 783 1.07 804 1.23 825 1.40 848 1.60 872 1.81 897 2.04 922 2.30 949 2.57 976 2.88 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM BHP Medium Static Option High Static Option 886 1.34 934 1.48 979 1.61 1022 1.74 904 1.52 950 1.67 995 1.82 1037 1.97 923 1.72 968 1.88 1012 2.04 1053 2.20 943 1.94 987 2.11 1030 2.29 1071 2.46 964 2.18 1007 2.36 1049 2.55 1089 2.731 986 2.44 1029 2.63 1069 2.83 1108 3.02 1010 2.71 1051 2.92 1090 3.13 1129 3.34 1034 3.02 1074 3.24 1112 3.46 1150 3.68 1058 3.34 1097 3.57 --------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied motor pulley (part no. KR11HY310), fan pulley (part no. KR11AZ002) and belt (part no. KR29AF054). 64 FAN PERFORMANCE (cont.) CFM 3000 3250 3500 3750 4000 4250 4500 4750 5000 CFM 3000 3250 3500 3750 4000 4250 4500 4750 5000 3 PHASE 0.2 RPM BHP Field Supplied Drive1 579 0.70 613 0.85 648 1.03 683 1.23 719 1.45 756 1.71 792 1.99 830 2.31 867 2.66 RPM 660 690 721 753 786 819 853 888 923 1.2 RPM BHP RPM 917 938 961 985 1011 1037 1064 1091 1120 1.70 1.93 2.18 2.46 2.76 3.09 3.46 3.85 4.28 970 991 1013 1035 1059 1084 1110 1137 1164 10 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.89 732 1.09 799 1.06 760 1.27 823 1.25 788 1.48 850 1.47 817 1.71 877 1.71 848 1.97 905 1.98 879 2.26 934 2.28 910 2.57 964 2.62 943 2.92 995 2.98 976 3.30 1026 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 BHP RPM BHP RPM Medium Static Option 1.91 1021 2.13 1070 2.16 1041 2.38 1089 2.42 1062 2.66 1108 2.71 1083 2.97 1129 3.03 1106 3.30 1151 3.38 1130 3.66 1174 3.76 1155 4.06 1198 4.16 1180 4.48 --4.61 ------- BHP 1.29 1.49 1.71 1.96 2.23 2.53 2.87 3.23 3.63 BHP 2.34 2.61 2.91 3.23 3.58 3.95 4.36 ----- 1.0 RPM BHP Medium Static Option 860 1.50 883 1.71 907 1.95 933 2.21 959 2.50 987 2.81 1015 3.16 1044 3.54 1074 3.95 2.0 RPM BHP High Static Option 1117 2.56 1134 2.85 1153 3.15 1173 3.49 1194 3.85 1216 4.24 1239 4.66 --------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 1. Recommend using field supplied fan pulley (part no. KR11AD912) and belt (part no. KR29AF051). Table 53 – 580J**12 CFM 3000 3250 3500 3750 4000 4250 4500 4750 5000 CFM 3000 3250 3500 3750 4000 4250 4500 4750 5000 3 PHASE 0.2 RPM BHP RPM 616 655 695 736 777 818 860 902 944 0.79 0.96 1.17 1.41 1.68 1.98 2.32 2.69 3.11 689 724 760 797 834 873 912 951 991 1.2 RPM BHP 939 962 987 1014 1042 1072 1103 1135 1167 1.79 2.03 2.30 2.60 2.93 3.30 3.70 4.14 4.63 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 0.97 757 1.16 821 1.16 788 1.37 849 1.38 821 1.60 879 1.63 855 1.86 910 1.91 889 2.16 942 2.23 925 2.49 976 2.58 962 2.85 1010 2.97 999 3.26 1046 3.40 1037 3.70 1082 10 TON VERTICAL SUPPLY BHP 1.36 1.58 1.83 2.10 2.41 2.75 3.13 3.55 4.00 1.0 RPM BHP Medium Static Option 882 1.57 907 1.80 934 2.06 963 2.35 993 2.67 1025 3.02 1057 3.41 1091 3.84 1125 4.31 AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 994 2.01 1047 2.24 1098 2.47 1147 1015 2.26 1066 2.50 1115 2.75 1163 1038 2.54 2.80 1135 3.05 1181 1088 1063 2.86 1111 3.12 1157 3.39 1202 1090 3.20 1136 3.48 1180 3.76 1224 1118 3.58 1162 3.87 1205 4.16 --1147 4.00 1190 4.29 1232 4.60 --1177 4.45 ------------------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 65 BHP 2.71 3.00 3.32 3.66 4.04 --------- 580J Table 52 – 580J**12 FAN PERFORMANCE (cont.) Table 54 – 580J**14 CFM 580J 3438 3750 4063 4375 4688 5000 5313 5625 5938 6250 CFM 3438 3750 4063 4375 4688 5000 5313 5625 5938 6250 3 PHASE 0.2 RPM BHP RPM 639 683 728 774 820 867 914 962 1009 --- 0.98 1.23 1.52 1.85 2.23 2.66 3.15 3.69 4.30 --- 713 753 794 836 879 923 967 1012 1058 --- 1.2 RPM BHP 955 985 1017 1050 1084 1120 --------- 2.12 2.46 2.84 3.27 3.75 4.28 --------- 12.5 TON HORIZONTAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 BHP RPM BHP RPM Standard Static Option 1.20 781 1.43 843 1.47 817 1.71 877 1.78 855 2.04 912 2.13 894 2.41 949 2.53 935 2.83 987 2.98 976 3.30 1026 3.49 1018 3.83 1066 4.05 1061 4.42 --4.68 --------------- BHP 1.65 1.96 2.31 2.70 3.14 3.63 4.17 ------- 1.0 RPM BHP Medium Static Option 901 1.88 933 2.21 966 2.57 1001 2.98 1037 3.44 1074 3.95 1112 4.52 ------------- AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 RPM BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 1007 2.35 1056 2.59 1103 2.83 1148 1035 2.71 1083 2.97 1129 3.23 1173 1066 3.12 1112 3.39 1157 3.67 1200 1097 3.56 1142 3.86 1186 4.15 1228 1130 4.06 1174 4.37 1216 4.68 1257 1164 4.61 ----1248 5.27 1288 ------------------------------------------------------- BHP 3.08 3.49 3.95 4.45 5.00 5.60 --------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. Table 55 – 580J**14 CFM 3438 3750 4063 4375 4688 5000 5313 5625 5938 6250 CFM 3438 3750 4063 4375 4688 5000 5313 5625 5938 6250 3 PHASE 0.2 RPM BHP 685 736 787 839 891 944 997 1051 ----- 1.12 1.41 1.75 2.14 2.60 3.11 3.69 4.34 ----- 12.5 TON VERTICAL SUPPLY AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 0.4 0.6 0.8 1.0 RPM BHP RPM BHP RPM BHP RPM Standard Static Option Medium Static Option 751 1.32 813 1.54 871 1.76 927 797 1.63 855 1.86 910 2.10 963 844 1.99 898 2.24 951 2.49 1001 892 2.40 943 2.67 993 2.94 1041 941 2.87 990 3.15 1037 3.44 1082 991 3.40 1037 3.70 1082 4.00 1125 1042 4.00 1085 4.32 1128 4.64 --1093 4.67 --------------------------------------- 1.2 RPM BHP RPM 981 1014 1049 1087 1126 1167 --------- 2.23 2.60 3.02 3.49 4.03 4.63 --------- 1032 1063 1097 1132 1169 ----------- AVAILABLE EXTERNAL STATIC PRESSURE (in. wg) 1.4 1.6 1.8 2.0 BHP RPM BHP RPM BHP RPM Medium Static Option High Static Option 2.47 1082 2.72 1130 2.97 1177 2.86 1111 3.12 1157 3.39 1202 3.29 1142 3.57 1186 3.85 1230 3.78 1176 4.08 1218 4.37 1260 4.33 1211 4.64 ------------------------------------------------------------------- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 66 BHP 1.99 2.35 2.75 3.21 3.73 4.31 --------- BHP 3.23 3.66 4.14 4.68 ------------- 3 PHASE 0.2 CFM 4500 4875 5250 5625 6000 6375 6750 7125 7500 RPM 487 515 544 572 601 630 659 689 718 BHP 0.98 1.18 1.42 1.68 1.98 2.31 2.68 3.09 3.53 RPM 552 578 604 631 657 684 711 739 766 1.2 CFM 4500 4875 5250 5625 6000 6375 6750 7125 7500 0.4 RPM 769 784 800 819 839 860 882 904 928 1.4 BHP 2.56 2.84 3.16 3.52 3.92 4.36 4.84 5.36 5.93 RPM 819 831 845 862 880 899 920 941 --- --- --- --- 15 TON VERTICAL SUPPLY Available External Static Pressure (in. wg) 0.6 0.8 BHP RPM BHP RPM 1.26 610 1.55 665 1.49 633 1.80 685 1.75 657 2.09 707 2.05 682 2.40 730 2.37 707 2.75 753 2.73 733 3.13 777 3.12 759 3.55 802 3.55 785 4.01 827 4.02 811 4.51 852 1.0 BHP 1.86 2.13 2.43 2.76 3.13 3.53 3.98 4.46 4.98 Available External Static Pressure (in. wg) 1.6 1.8 BHP RPM BHP RPM BHP 2.95 866 3.36 912 3.79 3.23 877 3.65 921 4.09 3.56 889 3.98 932 4.43 3.93 903 4.36 944 4.81 4.34 920 4.77 959 5.23 4.79 937 5.23 975 5.70 5.28 957 5.74 --- --- --- ----- --- --- --5.82 --- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- --- RPM 718 735 754 775 797 819 843 867 891 BHP 2.20 2.47 2.78 3.13 3.52 3.94 4.40 4.91 5.46 2.0 RPM 957 964 974 985 997 --- --- --- ----- --- --- ----- --- --- ----- --- --- --- BHP 4.24 4.54 4.89 5.28 5.70 --- --- --- ----- --- --- ----- --- --- ----- --- --- --- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. Table 57 – 580J**16 3 PHASE CFM 4500 4875 5250 5625 6000 6375 6750 7125 7500 0.2 RPM 479 508 537 566 596 625 655 685 715 1.2 CFM 4500 4875 5250 5625 6000 6375 6750 7125 7500 BHP 0.97 1.19 1.43 1.71 2.02 2.36 2.75 3.17 3.64 RPM 755 768 783 800 819 840 861 884 907 1.4 BHP 2.48 2.75 3.06 3.40 3.79 4.23 4.70 5.23 5.79 15 TON HORIZONTAL SUPPLY Available External Static Pressure (in. wg) 0.4 0.6 0.8 RPM BHP RPM BHP RPM 540 1.23 596 1.50 651 566 1.47 619 1.75 670 592 1.73 643 2.03 691 619 2.03 667 2.35 713 646 2.36 692 2.70 736 674 2.73 718 3.09 760 701 3.14 744 3.52 785 729 3.58 771 3.99 810 758 4.07 798 4.50 836 RPM 805 815 828 843 860 878 898 919 --- --- --- --- Available External Static Pressure (in. wg) 1.6 1.8 BHP RPM BHP RPM 2.87 853 3.28 900 3.14 862 3.55 907 3.45 872 3.86 916 3.80 885 4.21 926 4.19 900 4.61 939 4.63 916 5.06 954 5.12 935 5.56 971 5.66 --- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- ----- --- --- --- NOTE: For more information, see General Fan Performance Notes. Boldface indicates field supplied drive is required. 67 1.0 BHP 1.80 2.06 2.35 2.68 3.05 3.46 3.91 4.40 4.93 RPM 703 719 737 757 778 800 824 848 872 BHP 3.72 3.99 4.30 4.66 5.06 5.51 6.01 --- --- --- ----- --- --- --- RPM 945 951 958 967 978 991 --- --- --- ----- --- --- ----- --- --- --- BHP 2.13 2.39 2.69 3.03 3.41 3.83 4.30 4.81 5.36 2.0 BHP 4.17 4.45 4.77 5.12 5.53 5.98 --- --- --- ----- --- --- ----- --- --- --- 580J Table 56 – 580J*16 FAN PERFORMANCE (cont.) Table 58 – PULLEY ADJUSTMENT 1 phase 1 phase 3 phase 05 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 3 phase 06 07 08 09 12 14 16 580J 3 phase 04 1 phase UNIT MOTOR/DRIVE COMBO 0.0 0.5 1.0 MOTOR PULLEY TURNS OPEN 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Standard Static 854 825 795 766 736 707 678 648 619 589 560 Medium Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 High Static --- --- --- --- --- --- --- --- --- --- --- Standard Static 854 825 795 766 736 707 678 648 619 589 560 Medium Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 High Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 Standard Static 854 825 795 766 736 707 678 648 619 589 560 Medium Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 High Static --- --- --- --- --- --- --- --- --- --- --- Standard Static 854 825 795 766 736 707 678 648 619 589 560 Medium Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 High Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 Standard Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 Medium Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 High Static --- --- --- --- --- --- --- --- --- --- --- Standard Static 1175 1135 1094 1054 1013 973 932 892 851 811 770 Medium Static 1466 1423 1380 1337 1294 1251 1207 1164 1121 1078 1035 High Static 1687 1649 1610 1572 1533 1495 1457 1418 1380 1341 1303 Standard Static 1457 1419 1380 1342 1303 1265 1227 1188 1150 1111 1073 Medium Static 1518 1484 1449 1415 1380 1346 1311 1277 1242 1208 1173 High Static 1788 1757 1725 1694 1662 1631 1600 1568 1537 1505 1474 Standard Static 747 721 695 670 644 618 592 566 541 515 489 Medium Static 949 927 906 884 863 841 819 798 776 755 733 High Static 1102 1083 1063 1044 1025 1006 986 967 948 928 909 Standard Static 733 712 690 669 647 626 604 583 561 540 518 Medium Static 936 911 887 862 838 813 788 764 739 715 690 High Static 1084 1059 1035 1010 986 961 936 912 887 863 838 Standard Static 838 813 789 764 739 715 690 665 640 616 591 Medium Static 1084 1059 1035 1010 986 961 936 912 887 863 838 High Static 1240 1218 1196 1175 1153 1131 1109 1087 1066 1044 1022 Standard Static 838 813 789 764 739 715 690 665 640 616 591 Medium Static 1084 1059 1035 1010 986 961 936 912 887 863 838 High Static 1240 1218 1196 1175 1153 1131 1109 1087 1066 1044 1022 Standard Static 643 619 596 572 548 525 501 477 456 430 406 Medium Static 936 900 864 828 792 756 719 683 647 611 575 High Static 888 872 857 841 826 810 794 779 763 748 732 NOTE: Do not adjust pulley further than 5 turns open. --- Factory settings 68 ELECTRICAL INFORMATION 1-- Stage Cooling V ---Ph---Hz VOLTAGE RANGE MIN MAX RLA LRA WATTS FLA 208--- 1--- 60 187 253 16.6 79 325 1.5 230--- 1--- 60 187 253 16.6 79 325 1.5 208--- 3--- 60 187 253 10.4 73 325 1.5 230--- 3--- 60 187 253 10.4 73 325 1.5 460--- 3--- 60 414 506 5.8 38 325 0.8 575--- 3--- 60 518 633 3.8 37 325 0.6 COMP (ea) Table 60 – 580J*05A V ---Ph---Hz 3 TONS OFM (ea) IFM TYPE EFF at Full Load FLA Std Static Med Static Std Static Med Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 70% 70% 70% 70% 70% 70% 80% 70% 70% 80% 70% 70% 80% 71% 71% 80% 4.9 4.9 4.9 4.9 4.9 4.9 5.2 4.9 4.9 5.2 2.1 2.1 2.6 1.9 1.9 2.0 1-- Stage Cooling VOLTAGE RANGE MIN MAX COMP (ea) RLA LRA WATTS IFM FLA 208--- 1--- 60 187 253 21.8 117 325 1.5 230--- 1--- 60 187 253 21.8 117 325 1.5 208--- 3--- 60 187 253 13.7 83 325 1.5 230--- 3--- 60 187 253 13.7 83 325 1.5 460--- 3--- 60 414 506 6.2 41 325 0.8 575--- 3--- 60 518 633 4.8 37 325 0.6 Table 61 – 580J*06A 4 TONS OFM (ea) TYPE EFF at Full Load FLA Std Static Med Static Std Static Med Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 70% 78% 70% 78% 70% 70% 80% 70% 70% 80% 70% 70% 80% 71% 71% 80% 4.9 7.0 4.9 7.0 4.9 4.9 5.2 4.9 4.9 5.2 2.1 2.1 2.6 1.9 2.1 2.0 1-- Stage Cooling V ---Ph---Hz VOLTAGE RANGE MIN MAX RLA LRA WATTS FLA 208--- 1--- 60 187 253 26.2 134 325 1.5 230--- 1--- 60 187 253 26.2 134 325 1.5 208--- 3--- 60 187 253 15.6 110 325 1.5 230--- 3--- 60 187 253 15.6 110 325 1.5 460--- 3--- 60 414 506 7.7 52 325 0.8 575--- 3--- 60 518 633 5.8 39 325 0.6 COMP (ea) 5 TONS OFM (ea) IFM 69 TYPE EFF at Full Load FLA Std Static Med Static Std Static Med Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 70% 78% 70% 78% 70% 80% 81% 70% 80% 81% 70% 80% 81% 71% 81% 81% 4.9 7.0 4.9 7.0 4.9 5.2 7.5 4.9 5.2 7.5 2.1 2.6 3.4 1.9 2.0 2.8 580J Table 59 – 580J*04A ELECTRICAL INFORMATION (cont.) Table 62 – 580J*07A V ---Ph---Hz 580J 1-- Stage Cooling VOLTAGE RANGE COMP (ea) OFM (ea) IFM MIN MAX RLA LRA WATTS FLA 208--- 3--- 60 187 253 19.0 123 325 1.5 230--- 3--- 60 187 253 19.0 123 325 1.5 460--- 3--- 60 414 506 9.7 62 325 0.8 575--- 3--- 60 518 633 7.4 50 325 0.6 Table 63 – 580J*08A COMP (ea) EFF at Full Load FLA Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 7.5 7.5 5.2 7.5 7.5 2.6 3.4 4.4 2.0 2.8 2.8 7.5 TONS OFM (ea) IFM MIN MAX RLA LRA WATTS FLA 208--- 3--- 60 187 253 25.0 164 325 1.5 230--- 3--- 60 187 253 25.0 164 325 1.5 460--- 3--- 60 414 506 12.2 100 325 0.8 575--- 3--- 60 518 633 9.0 78 325 0.6 Table 64 – 580J*08D V ---Ph---Hz TYPE 1-- Stage Cooling VOLTAGE RANGE V ---Ph---Hz 6 TONS TYPE EFF at Full Load FLA Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 7.5 15.0 5.2 7.5 15.0 2.6 3.4 7.4 2.4 2.8 5.6 2-- Stage Cooling VOLTAGE RANGE COMP (Cir 1) COMP (Cir 2) 7.5 TONS OFM (ea) RLA LRA RLA LRA WATTS FLA 253 13.6 83 13.6 83 325 1.5 187 253 13.6 83 13.6 83 325 1.5 460--- 3--- 60 414 506 6.1 41 6.1 41 325 0.8 575--- 3--- 60 518 633 4.2 33 4.2 33 325 0.6 MIN MAX 208--- 3--- 60 187 230--- 3--- 60 70 IFM TYPE EFF at Full Load FLA STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 7.5 15.0 5.2 7.5 15.0 2.6 3.4 7.4 2.4 2.8 5.6 ELECTRICAL INFORMATION (cont.) 1-- Stage Cooling VOLTAGE RANGE V ---Ph---Hz MIN COMP (ea) MAX RLA OFM (ea) LRA WATTS IFM FLA 208--- 3--- 60 187 253 29.5 195 325 1.5 230--- 3--- 60 187 253 29.5 195 325 1.5 460--- 3--- 60 414 506 14.7 95 325 0.8 575--- 3--- 60 518 633 12.2 80 325 0.6 Table 66 – 580J*09D V ---Ph---Hz TYPE EFF at Full Load FLA Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 81% 5.2 5.2 10.0 5.2 5.2 10.0 2.6 2.6 4.4 2.4 2.0 2.8 2-- Stage Cooling VOLTAGE RANGE MIN 8.5 TONS COMP (Cir 1) RLA MAX COMP (Cir 2) LRA RLA 8.5 TONS OFM (ea) LRA WATTS IFM FLA 208--- 3--- 60 187 253 14.5 98 13.7 83 325 1.5 230--- 3--- 60 187 253 14.5 98 13.7 83 325 1.5 460--- 3--- 60 414 506 6.3 55 6.2 41 325 0.8 575--- 3--- 60 518 633 6.0 41 4.8 33 325 0.6 Table 67 – 580J*12A STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH EFF at Full Load 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 80% 81% 1-- Stage Cooling VOLTAGE RANGE V ---Ph---Hz TYPE COMP (ea) OFM (ea) IFM LRA WATTS FLA 253 30.1 225 325 1.5 187 253 30.1 225 325 1.5 460--- 3--- 60 414 506 16.7 114 325 0.8 575--- 3--- 60 518 633 12.2 80 325 0.6 MAX 208--- 3--- 60 187 230--- 3--- 60 71 5.2 5.2 10.0 5.2 5.2 10.0 2.6 2.6 4.4 2.4 2.0 2.8 10 TONS RLA MIN FLA TYPE EFF at Full Load FLA Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static Std Static Med Static High Static 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 10.0 15.0 5.2 10.0 15.0 2.6 4.4 7.4 2.0 2.8 5.6 580J Table 65 – 580J*09A ELECTRICAL INFORMATION (cont.) Table 68 – 580J*12D V ---Ph---Hz 580J 2-- Stage Cooling VOLTAGE RANGE COMP (Cir 1) 10 TONS COMP (Cir 2) OFM (ea) IFM RLA LRA RLA LRA WATTS FLA 253 15.6 110 15.9 110 325 1.5 187 253 15.6 110 15.9 110 325 1.5 460--- 3--- 60 414 506 7.7 52 7.7 52 325 0.8 575--- 3--- 60 518 633 5.8 39 5.7 39 325 0.6 MIN MAX 208--- 3--- 60 187 230--- 3--- 60 Table 69 – 580J*14D COMP (Cir 1) STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH 80% 81% 81% 80% 81% 81% 80% 81% 81% 80% 81% 81% 5.2 10.0 15.0 5.2 10.0 15.0 2.6 4.4 7.4 2.0 2.8 5.6 12.5 TONS COMP (Cir 2) OFM (ea) IFM RLA LRA RLA LRA WATTS FLA 253 19.0 123 22.4 149 1288 6.2 187 253 19.0 123 22.4 149 1288 6.2 460--- 3--- 60 414 506 9.7 62 10.6 75 1288 3.1 575--- 3--- 60 518 633 7.4 50 7.7 54 1288 2.5 MIN MAX 208--- 3--- 60 187 230--- 3--- 60 Table 70 – 580J*16D TYPE EFF at Full Load FLA STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% 7.5 10.0 15.0 7.5 10.0 15.0 3.4 4.4 7.4 2.8 2.8 5.6 2-- Stage Cooling 15 TONS VOLTAGE RANGE MIN MAX COMP (Cir 1) COMP (Cir 2) RLA LRA RLA LRA WATTS FLA 208-3-60 187 253 25.0 164 25.0 164 1288 1.5 230-3-60 187 253 25.0 164 25.0 164 1288 1.5 460-3-60 414 506 12.2 100 12.8 100 1288 0.8 575-3-60 518 633 9.8 78 9.6 78 1288 0.6 V ---Ph---Hz FLA 2-- Stage Cooling VOLTAGE RANGE V ---Ph---Hz TYPE EFF at Full Load 72 OFM (ea) IFM TYPE STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH EFF at Full Load 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% 81% FLA 7.5 10.0 17.0 7.5 10.0 15.0 3.4 4.4 7.6 2.8 2.8 6.1 NOM. V ---Ph---Hz 208/230--- 1--- 60 580J*04A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*05A 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*06A 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*07A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*08A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 IFM TYPE STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH COMBUSTION POWER FAN MOTOR EXHAUST FLA FLA 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 3.8 0.25 1.8 0.24 3.8 MCA 27.2 27.2 19.4 19.4 19.7 10.2 10.2 10.7 7.3 7.3 7.4 33.7 33.7 23.5 23.5 23.8 10.7 10.7 11.2 8.5 8.5 8.6 39.2 41.3 25.9 26.2 28.5 12.5 13.0 13.8 9.8 9.9 10.7 30.5 32.8 32.8 15.5 16.3 17.3 11.9 12.7 12.7 39.5 41.8 49.3 19.5 20.3 24.3 14.9 15.3 18.1 NO C.O. or UNPWRD C.O. NO P.E. w/ P.E. (pwrd fr/ unit) DISC. SIZE DISC. SIZE MOCP MCA MOCP FLA LRA FLA LRA 40.0 26 95 29.1 45.0 29 97 40.0 26 95 29.1 45.0 29 97 25.0 19 89 21.3 30.0 22 91 25.0 19 89 21.3 30.0 22 91 30.0 20 107 21.6 30.0 22 109 15.0 10 46 11.2 15.0 11 47 15.0 10 46 11.2 15.0 11 47 15.0 11 55 11.7 15.0 12 56 15.0 7 44 9.2 15.0 9 46 15.0 7 44 9.2 15.0 9 46 15.0 7 50 9.3 15.0 10 52 50.0 32 133 35.6 50.0 35 135 50.0 32 133 35.6 50.0 35 135 30.0 23 99 25.4 30.0 25 101 30.0 23 99 25.4 30.0 25 101 30.0 23 117 25.7 30.0 25 119 15.0 10 49 11.7 15.0 12 50 15.0 10 49 11.7 15.0 12 50 15.0 11 58 12.2 15.0 12 59 15.0 8 44 10.4 15.0 11 46 15.0 8 44 10.4 15.0 11 46 15.0 9 50 10.5 15.0 11 52 60.0 37 150 41.1 60.0 40 152 60.0 40 175 43.2 60.0 42 177 30.0 25 126 27.8 40.0 27 128 40.0 26 144 28.1 40.0 28 146 40.0 29 170 30.4 45.0 30 172 20.0 12 60 13.5 20.0 13 61 20.0 13 69 14.0 20.0 14 70 20.0 14 82 14.8 20.0 15 83 15.0 10 46 11.7 15.0 12 48 15.0 10 52 11.8 15.0 13 54 15.0 11 63 12.6 15.0 13 65 45 30 157 32.4 50 32 159 50 32 183 34.7 50 34 185 50 32 183 34.7 50 34 185 25 15 79 16.5 25 16 80 25 16 92 17.3 25 17 93 25 17 101 18.3 25 18 102 15 12 63 13.8 20 14 65 20 12 74 14.6 20 15 76 20 12 74 14.6 20 15 76 60 38 191 43.3 60 43 195 60 41 228 45.6 60 45 232 60 49 254 53.1 60 54 258 30 19 113 21.3 30 21 115 30 20 132 22.1 30 22 134 30 24 145 26.1 30 26 147 20 14 89 18.7 25 19 93 20 15 104 19.1 25 19 108 25 18 118 21.9 30 23 122 73 580J UNIT Table 71 – MCA/MOCP DETERMINATION NO C.O. OR UNPWRD C.O. UNIT TABLE 67 (cont.) MCA/MOCP DETERMINATION NO C.O. OR UNPWRD C.O. NOM. V-- Ph -- Hz 580J*08D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*09A 460--- 3--- 60 575--- 3--- 60 580J*09D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*12A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*12D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*14D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 208/230--- 3--- 60 580J*16D 580J 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 IFM TYPE STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH High High Eff. STD MED HIGH High High Eff. STD MED HIGH High High Eff. COMBUSTION FAN MOTOR FLA POWER EXHAUST FLA 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.25 1.8 0.24 3.8 0.48 3.8 0.48 3.8 0.25 1.8 0.25 1.8 0.24 3.8 0.24 3.8 NO C.O. or UNPWRD C.O. w/ P.E. (pwrd fr/ unit) DISC. SIZE DISC. SIZE MCA MOCP FLA LRA FLA LRA 41 193 42.6 50 45 197 43 230 44.9 50 48 234 52 256 52.8 60 56 260 19 95 19.7 25 21 97 20 114 20.5 25 22 116 24 127 24.9 30 26 129 14 77 16.9 20 18 81 14 92 17.3 20 19 96 17 106 20.4 25 22 110 43 222 48.9 60 48 226 43 233 48.9 60 48 237 49 276 53.7 80 53 280 22 108 24.4 30 24 110 22 114 24.4 30 24 116 24 136 26.2 30 26 138 18 91 22.7 30 23 95 18 95 22.3 30 22 99 19 106 23.1 30 23 110 42 208 43.8 50 46 212 42 219 43.8 50 46 223 47 262 48.6 60 52 266 19 109 20.1 25 21 111 19 115 20.1 25 21 117 21 137 21.9 25 23 139 17 85 19.7 25 21 89 16 89 19.3 25 20 93 17 100 20.1 25 21 104 44 263 49.6 60 48 267 50 306 54.4 80 54 310 55 315 59.4 80 60 319 24 133 26.9 40 26 135 26 155 28.7 45 28 157 30 159 31.7 45 32 161 18 95 22.3 30 22 99 19 106 23.1 30 23 110 22 120 25.9 30 26 124 46 258 47.5 60 50 262 51 301 52.3 60 56 305 57 310 57.3 70 61 314 23 123 23.3 30 25 125 25 145 25.1 30 27 147 28 149 28.1 35 30 151 17 93 20.0 25 21 97 18 104 20.8 25 22 108 21 118 23.6 30 25 122 63 360 64.5 80 68 364 66 377 67.0 80 71 381 72 386 72.0 80 76 390 31 181 31.3 40 33 183 32 190 32.3 40 34 192 35 194 35.3 45 37 196 23 142 26.1 30 28 146 23 142 26.1 30 28 146 27 156 28.9 35 31 100 71 396 72.1 80 76 400 74 413 74.6 90 79 417 82/80 424 81.6/79.6 100/100 87/84 428 86 432 85.0 100 91 436 35 234 35.8 45 37 236 37 243 36.8 45 39 245 40 248 40.0 50 42 250 43 252 42.6 50 45 254 28 184 30.3 40 32 188 28 184 30.3 40 32 188 31 187 33.6 40 36 191 35 196 36.5 45 39 200 NO P.E. MCA MOCP 38.8 41.1 49.0 17.9 18.7 23.1 13.1 13.5 16.6 45.1 45.1 49.9 22.6 22.6 24.4 18.9 18.5 19.3 40.0 40.0 44.8 18.3 18.3 20.1 15.9 15.5 16.3 45.8 50.6 55.6 25.1 26.9 29.9 18.5 19.3 22.1 43.7 48.5 53.5 21.5 23.3 26.3 16.2 17.0 19.8 60.7 63.2 68.2 29.5 30.5 33.5 22.3 22.3 25.1 68.3 70.8 77.8/75.8 81.2 34.0 35.0 38.2 40.8 26.5 26.5 29.8 32.7 50 50 60 20 25 30 15 15 20 60 60 60 30 30 30 30 30 30 50 50 50 20 20 25 20 20 20 60 60 80 30 40 45 30 30 30 50 60 60 25 30 30 20 20 25 80 80 80 40 40 40 30 30 30 80 80 100/100 100 45 45 50 50 30 30 35 40 74 NOM. V ---Ph---Hz 580J*04A 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*05A 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*06A 208/230--- 1--- 60 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*07A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*08A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 IFM TYPE STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH COMBUSTION POWER FAN MOTOR EXHAUST FLA FLA 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 1.9 0.25 1.0 0.24 1.9 0.48 3.8 0.25 1.8 0.24 3.8 MCA 32.0 32.0 24.2 24.2 24.5 12.4 12.4 12.9 9.0 9.0 9.1 38.5 38.5 28.3 28.3 28.6 12.9 12.9 13.4 10.2 10.2 10.3 44.0 46.1 30.7 31.0 33.3 14.7 15.2 16.0 11.5 11.6 12.4 35.3 37.6 37.6 17.7 18.5 19.5 13.6 14.4 14.4 44.3 46.6 54.1 21.7 22.5 26.5 16.6 17.0 19.8 w/ PWRD C.O. NO P.E. w/ P.E. (pwrd fr/ unit) DISC. SIZE DISC. SIZE MOCP MCA MOCP FLA LRA FLA LRA 45.0 32 100 33.9 50.0 34 102 45.0 32 100 33.9 50.0 34 102 30.0 25 94 26.1 30.0 27 96 30.0 25 94 26.1 30.0 27 96 30.0 25 112 26.4 30.0 27 114 15.0 13 48 13.4 15.0 14 49 15.0 13 48 13.4 15.0 14 49 15.0 13 57 13.9 20.0 14 58 15.0 9 46 10.9 15.0 11 48 15.0 9 46 10.9 15.0 11 48 15.0 9 52 11.0 15.0 12 54 60.0 38 138 40.4 60.0 40 140 60.0 38 138 40.4 60.0 40 140 40.0 29 104 30.2 40.0 31 106 40.0 29 104 30.2 40.0 31 106 40.0 29 122 30.5 40.0 31 124 15.0 13 51 13.9 20.0 14 52 15.0 13 51 13.9 20.0 14 52 15.0 14 60 14.4 20.0 15 61 15.0 10 46 12.1 15.0 13 48 15.0 10 46 12.1 15.0 13 48 15.0 10 52 12.2 15.0 13 54 60.0 43 155 45.9 60.0 45 157 60.0 45 180 48.0 60.0 48 182 45.0 31 131 32.6 45.0 33 133 45.0 31 149 32.9 45.0 33 151 45.0 34 175 35.2 50.0 36 177 20.0 15 62 15.7 20.0 16 63 20.0 15 71 16.2 20.0 16 72 20.0 16 84 17.0 20.0 17 85 15.0 12 48 13.4 15.0 14 50 15.0 12 54 13.5 15.0 14 56 15.0 13 65 14.3 20.0 15 67 50.0 35 162 37.2 50.0 37 164 50.0 38 188 39.5 50.0 40 190 50.0 38 188 39.5 50.0 40 190 25.0 18 81 18.7 25.0 19 82 25.0 19 94 19.5 25.0 20 95 25.0 20 103 20.5 30.0 21 104 20.0 13 65 15.5 20.0 16 67 20.0 14 76 16.3 20.0 17 78 20.0 14 76 16.3 20.0 17 78 60 44 196 48.1 60 48 200 60 46 233 50.4 60 51 237 70 55 259 57.9 80 59 263 30 21 115 23.5 30 23 117 30 22 134 24.3 30 24 136 30 27 147 28.3 40 29 149 25 16 91 20.4 25 21 95 25 17 106 20.8 25 21 110 25 20 120 23.6 30 24 124 75 580J UNIT Table 72 – MCA/MOCP DETERMINATION W/ PWRD C.O. UNIT TABLE 68 (cont.) MCA/MOCP DETERMINATION W/ PWRD C.O. NOM. V ---Ph---Hz 580J*08D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*09A 460--- 3--- 60 575--- 3--- 60 580J*09D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*12A 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*12D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 580J*14D 208/230--- 3--- 60 460--- 3--- 60 575--- 3--- 60 208/230--- 3--- 60 STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED HIGH STD MED High STD MED HIGH STD MED HIGH STD MED High High ---High Eff. 580J*16D 580J 208/230--- 3--- 60 IFM TYPE 460--- 3--- 60 575--- 3--- 60 STD MED HIGH High ---High Eff. COMBUSTION POWER FAN MOTOR EXHAUST FLA FLA MCA MOCP 43.6 50 45.9 50 0.48 3.8 53.8 60 20.1 25 20.9 25 0.25 1.8 25.3 30 14.8 20 15.2 20 0.24 3.8 18.3 20 49.9 60 49.9 60 0.48 3.8 54.7 80 24.8 30 24.8 30 0.25 1.8 26.6 40 20.6 30 20.2 30 0.24 3.8 21.0 30 44.8 50 44.8 50 0.48 3.8 49.6 60 20.5 25 20.5 25 0.25 1.8 22.3 25 17.6 20 17.2 20 0.24 3.8 18.0 20 50.6 60 55.4 80 0.48 3.8 60.4 80 27.3 40 29.1 45 0.25 1.8 32.1 45 20.2 30 21.0 30 0.24 3.8 23.8 30 48.5 60 53.3 60 0.48 3.8 58.3 70 23.7 30 25.5 30 0.25 1.8 28.5 35 17.9 20 18.7 25 0.24 3.8 21.5 25 65.5 80 0.48 3.8 68.0 80 Model not available due to high amperage draw. 31.7 40 32.7 40 0.25 1.8 35.7 45 24.0 30 24.0 30 0.24 3.8 26.8 30 73.1 80 0.48 3.8 75.6 100 82.6/80.6 100/100 0.48 w/ PWRD C.O. NO P.E. DISC. SIZE FLA LRA 46 198 49 235 58 261 21 97 22 116 27 129 16 79 16 94 19 108 49 227 49 238 54 281 24 110 24 116 26 138 20 93 20 97 21 108 47 213 47 224 53 267 22 111 22 117 24 139 19 87 18 91 19 102 50 268 55 311 61 320 27 135 29 157 32 161 20 97 21 108 24 122 51 263 57 306 62 315 25 125 27 147 31 151 19 95 20 106 23 120 69 365 72 382 33 35 38 25 25 29 77 80 88/85 183 192 196 144 144 158 401 418 429 w/ P.E. (pwrd fr/ unit) DISC. SIZE MCA MOCP FLA LRA 47.4 60 51 202 49.7 60 53 239 57.6 70 62 265 21.9 25 23 99 22.7 25 24 118 27.1 30 29 131 18.6 20 20 83 19.0 25 21 98 22.1 25 24 112 53.7 80 53 231 53.7 80 53 242 58.5 80 59 285 26.6 40 26 112 26.6 40 26 118 28.4 40 28 140 24.4 30 24 97 24.0 30 24 101 24.8 30 25 112 48.6 60 52 217 48.6 60 52 228 53.4 60 57 271 22.3 25 24 113 22.3 25 24 119 24.1 30 26 141 21.4 25 23 91 21.0 25 22 95 21.8 25 23 106 54.4 80 54 272 59.2 80 59 315 64.2 80 65 324 29.1 45 29 137 30.9 45 31 159 33.9 50 34 163 24.0 30 24 101 24.8 30 25 112 27.6 35 28 126 52.3 60 56 267 57.1 70 61 310 62.1 70 67 319 25.5 30 27 127 27.3 30 29 149 30.3 35 33 153 21.7 25 23 99 22.5 25 24 110 25.3 30 27 124 69.3 80 73 369 71.8 80 76 386 33.5 40 34.5 45 37.5 45 27.8 30 27.8 30 30.6 35 76.9 100 79.4 100 86.4/84.4 100/100 35 37 40 30 30 33 81 84 92/90 185 194 198 148 148 162 405 422 433 3.8 86.0 100 92 437 89.8 100 96 441 0.25 1.8 36.2 37.2 40.4 45 50 50 38 39 43 236 245 250 38.0 39.0 42.2 50 50 50 40 41 45 238 247 252 0.25 1.8 43.0 50 46 254 44.8 50 48 256 35 35 40 30 30 33 186 186 189 32.0 32.0 35.3 40 40 45 34 34 38 190 190 193 40 37 198 38.2 45 41 202 STD MED HIGH 0.24 3.8 28.2 28.2 31.5 High ---High Eff. 0.24 3.8 34.4 76 580J TYPICAL WIRING DIAGRAMS C08518B Fig. 24 -- 1--Stage Cooling Typical Power Diagram 77 580J C08577B Fig. 25 -- 2--Stage Cooling Typical Power Diagram 78 79 Fig. 26 -- 1--Stage Typical Wiring Diagram 580J C08524 80 Fig. 27 -- 2--Stage Typical Wiring Diagram 580J C08578 SEQUENCE OF OPERATION The sequence below describes the sequence of operation for an electromechanical unit with and without a factory installed EconoMi$er IV (called “economizer” in this sequence). For information regarding a direct digital controller, see the start-- up, operations, and troubleshooting manual for the applicable controller. Electromechanical units with no economizer Cooling — When the thermostat calls for cooling, terminals G and Y1 are energized. As a result, the indoor fan contactor (IFC) and the compressor contactor (C1) are energized, causing the indoor fan motor (IFM), compressor #1, and outdoor fan to start. If the unit has 2 stages of cooling, the thermostat will additionally energize Y2. The Y2 signal will energize compressor contactor #2 (C2), causing compressor #2 to start. Regardless of the number of stages, the outdoor fan motor runs continuously while unit is cooling. Heating NOTE: Legacy Line (580J) units have either 1 or 2 stages of gas heat. When the thermostat calls for heating, power is sent to W on the Integrated Gas Controller (IGC) board. An LED (light-- emitting diode) on the IGC board turns on and remains on during normal operation. A check is made to ensure that the rollout switch and limit switch are closed. If the check was successful, the induced-- draft motor is energized, and when its speed is satisfactory, as proven by the “hall effect” sensor, the ignition activation period begins. The burners will ignite within 5 seconds. If the burners do not light, there is a 22-- second delay before another 5-- second attempt. This sequence is repeated for 15 minutes or until the burners light. If, after the 15 minutes, the burners still have not lit, heating is locked out. To reset the control, break 24-- v power to the thermostat. When ignition occurs, the IGC board will continue to monitor the condition of the rollout switch, the limit switches, the “hall effect” sensor, as well as the flame sensor. 45 seconds after ignition occurs, assuming the unit is controlled through a room thermostat set for fan auto, the indoor fan motor will energize (and the outdoor air dampers will open to their minimum position). If, for some reason, the over-- temperature limit opens prior to the start of the indoor fan blower, the unit will shorten the 45-- second delay to 5 seconds less than the time from initiation of heat to when the limit tripped. Gas will not be interrupted to the burners and heating will continue. Once the fan-- on delay has been modified, it will not change back to 45 seconds until power is reset to the control. On units with 2 stages of heat, when additional heat is required, W2 closes and initiates power to the second stage of the main gas valve. When the thermostat is satisfied, W1 and W2 open and the gas valve closes, interrupting the flow of gas to the main burners. If the call for W1 lasted less than 1 minute, the heating cycle will not terminate until 1 minute after W1 became active. If the unit is controlled through a room thermostat set for fan auto, the indoor fan motor will continue to operate for an additional 45 seconds then stop. If the over-- temperature limit opens after the indoor motor is stopped, but within 10 minutes of W1 becoming inactive, on the next cycle the time will be extended by 15 seconds. The maximum delay is 3 minutes. Once modified, the fan off delay will not change back to 45 seconds unless power is reset to the control. A LED indicator is provided on the IGC to monitor operation. Electromechanical units with an economizer Cooling — When free cooling is not available, the compressors will be controlled by the zone thermostat. When free cooling is available, the outdoor air damper is modulated by the EconoMi$er IV control to provide a 50_F (10_C) to 55_F (13_C) mixed air temperature into the zone. As the mixed air temperature fluctuates above 55_F (13_C)or below 50_F (10_C) dampers will be modulated (open or close) to bring the mixed air temperature back within control. If mechanical cooling is utilized with free cooling, the outdoor air damper will maintain its current position at the time the compressor is started. If the increase in cooling capacity causes the mixed air temperature to drop below 45_F (7_C), then the outdoor air damper position will be decreased to the minimum position. If the mixed air temperature continues to fall, the outdoor air damper will close. Control returns to normal once the mixed air temperature rises above 48_F (9_C). The power exhaust fans will be energized and de-- energized, if installed, as the outdoor air damper opens and closes. If field installed accessory CO2 sensors are connected to the EconoMi$er IV control, a demand controlled ventilation strategy will begin to operate. As the CO2 level in the zone increases above the CO2 setpoint, the minimum position of the damper will be increased proportionally. As the CO2 level decreases because of the increase in fresh air, the outdoor air damper will be proportionally closed. For EconoMi$er IV operation, there must be a thermostat call for the fan (G). If the unit is occupied and the fan is on, the damper will operate at minimum position. Otherwise, the damper will be closed. When the EconoMi$er IV control is in the occupied mode and a call for cooling exists (Y1 on the thermostat), the control will first check for indoor fan operation. If the fan is not on, then cooling will not be activated. If the fan is on, then the control will open the EconoMi$er IV damper to the minimum position. 81 580J General 580J SEQUENCE OF OPERATION (cont.) On the initial power to the EconoMi$er IV control, it will take the damper up to 2 1/2 minutes before it begins to position itself. After the initial power-- up, further changes in damper position can take up to 30 seconds to initiate. Damper movement from full closed to full open (or vice versa) will take between 1 1/2 and 2 1/2 minutes. If free cooling can be used as determined from the appropriate changeover command (switch, dry bulb, enthalpy curve, differential dry bulb, or differential enthalpy), then the control will modulate the dampers open to maintain the mixed air temperature setpoint at 50_F (10_C) to 55_F (13_C). If there is a further demand for cooling (cooling second stage - Y2 is energized), then the control will bring on compressor stage 1 to maintain the mixed air temperature setpoint. The EconoMi$er IV damper will be open at maximum position. EconoMi$er IV operation is limited to a single compressor. Heating The sequence of operation for the heating is the same as an electromechanical unit with no economizer. The only difference is how the economizer acts. The economizer will stay at the Economizer Minimum Position while the evaporator fan is operating. The outdoor air damper is closed when the indoor fan is not operating. Optional Perfect Humidity System Units with the factory equipped Perfect Humidity option are capable of providing multiple modes of improved dehumidification as a variation of the normal cooling cycle. The Perfect Humidity option includes additional valves in the liquid line and discharge line of each refrigerant circuit, a small reheat condenser coil downstream of the evaporator, and Motormaster variable-- speed control of some or all outdoor fans. Operation of the revised refrigerant circuit for each mode is described below. NOTE: x = refrigerant circuit A, B, or C. Normal Cooling Refrigerant flows from the outdoor condenser through the normally open Cooling Valve (CV.x) to the expansion device. Reheat1 Valve (RH1.x) and Reheat2 Valve (RH2.x) are closed. Reheat1 (Subcooling Mode) -- 580J04--16 This mode increases latent cooling and decreases sensible cooling compared to normal cooling. Refrigerant flows from the outdoor condenser, through the normally open Reheat1 Valve (RH1.x), and through the reheat condenser coil to the expansion device. Cooling Valve (CV.x) and Reheat2 Valve (RH2.x) are closed. Reheat2 (Hot Gas Reheat Mode) -- 580J04--16 This mode provides maximum latent cooling with little to no sensible capacity. This mode can operate to provide dehumidification when there is no cooling demand. Like Reheat1 mode, refrigerant flows from the outdoor condenser, through the normally open Reheat1 Valve (RH1.x), and through the reheat condenser coil to the expansion device. The Cooling Valve (CV.x) is closed. Reheat2 Valve (RH2.x) is open which provides some compressor discharge gas to the reheat condenser to further increase the reheat of the evaporator airstream. RH2.x RH1.x PERFECT HUMIDITY COIL COND COIL COMP CV.x OUTDOOR AIR METERING DEVICE EVAP COIL CLOSED VALVE OPEN VALVE INDOOR ENTERING AIR a48-8172 C09455 Normal Cooling Mode -- Perfect Humidity System (580J04--16) 82 RH2.x RH1.x COND COIL COMP PERFECT HUMIDITY COIL CV.x METERING DEVICE EVAP COIL CLOSED VALVE OPEN VALVE INDOOR ENTERING AIR a48-8173 C09456 Subcooling Mode (Reheat 1) -- Perfect Humidity System (580J04--16) RH2.x RH1.x COND COIL COMP PERFECT HUMIDITY COIL CV.x OUTDOOR AIR METERING DEVICE EVAP COIL CLOSED VALVE OPEN VALVE INDOOR ENTERING AIR a48-8174 C09457 Hot Gas Reheat Mode (Reheat2) -- Perfect Humidity System (580J04--16) 83 580J OUTDOOR AIR GUIDE SPECIFICATIONS -- 580J**04--16 Gas Heat/Electric Cooling Packaged Rooftop HVAC Guide Specifications Size Range: 3 to 15 Nominal Tons Section Description 23 06 80 Schedules for Decentralized HVAC Equipment 23 06 80.13 Decentralized Unitary HVAC Equipment Schedule 23 06 80.13.A. Rooftop unit schedule 1. Schedule is per the project specification requirements. 580J 23 07 16 HVAC Equipment Insulation 23 07 16.13 Decentralized, Rooftop Units: 23 07 16.13.A. Evaporator fan compartment: 1. Interior cabinet surfaces shall be insulated with a minimum 1/2-- in. thick, minimum 1 1/2 lb density, flexible fiberglass insulation bonded with a phenolic binder, neoprene coated on the air side. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 07 16.13.B. Gas heat compartment: 1. Aluminum foil-- faced fiberglass insulation shall be used. 2. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 23 09 13 Instrumentation and Control Devices for HVAC 23 09 13.23 Sensors and Transmitters 23 09 13.23.A. Thermostats 1. Thermostat must a. energize both “W” and “G” when calling for heat. b. have capability to energize 2 different stages of cooling, and 2 different stages of heating. c. include capability for occupancy scheduling. 23 09 23 Direct-- digital Control system for HVAC 23 09 23.13 Decentralized, Rooftop Units: 23 09 23.13.B. RTU Open - Open protocol, direct digital controller: 1. Shall be ASHRAE 62-- 2001 compliant. 2. Shall accept 18-- 30VAC, 50-- 60Hz, and consumer 15VA or less power. 3. Shall have an operating temperature range from - 40_F (-- 40_C) to 130_F (54_C), 10% - 90% RH (non-- condensing). 4. Shall include built-- in protocol for BACNET (MS/TP and PTP modes), Modbus (RTU and ASCII), Johnson N2 and LonWorks. LonWorks Echelon processor required for all Lon applications shall be contained in separate communication board. 5. Shall allow access of up to 62 network variables (SNVT). Shall be compatible with all open controllers 6. Baud rate Controller shall be selectable using a dipswitch. 7. Shall have an LED display independently showing the status of serial communication, running, errors, power, all digital outputs, and all analog inputs. 8. Shall accept the following inputs: space temperature, setpoint adjustment, outdoor air temperature, indoor air quality, outdoor air quality, compressor lock-- out, fire shutdown, enthalpy switch, and fan status/filter status/ humidity/ remote occupancy. 9. Shall provide the following outputs: economizer, fan, cooling stage 1, cooling stage 2, heat stage 1, heat stage 2, heat stage 3/ exhaust/ reversing valve. 10. Shall have built-- in surge protection circuitry through solid state polyswitches. Polyswitches shall be used on incoming power and network connections. Polyswitches will return to normal when the “trip” condition clears. 11. Shall have a battery back-- up capable of a minimum of 10,000 hours of data and time clock retention during power outages. 12. Shall have built-- in support for Bryant technician tool. 84 13. Shall include an EIA-- 485 protocol communication port, an access port for connection of either a computer or a Bryant technician tool, an EIA-- 485 port for network communication to intelligent space sensors and displays, and a port to connect an optional LonWorks communications card. 14. Software upgrades will be accomplished by either local or remote download. No software upgrades through chip replacements are allowed. Electric and Electronic Control System for HVAC 23 09 33.13 Decentralized, Rooftop Units: 23 09 33.13.A. General: 1. Shall be complete with self-- contained low-- voltage control circuit protected by a resettable circuit breaker on the 24-- v transformer side. Transformer shall have 75VA capability. 2. Shall utilize color-- coded wiring. 3. Shall include a central control terminal board to conveniently and safely provide connection points for vital control functions such as: smoke detectors, phase monitor, gas controller, economizer, thermostat, DDC control options, and low and high pressure switches. 4. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. See heat exchanger section of this specification. 5. Unit shall include a minimum of one 8-- pin screw terminal connection board for connection of control wiring. 23 09 33.23.B. Safeties: 1. Compressor over-- temperature, over-- current. High internal pressure differential. 2. Low pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross-- wiring of the safety switches between circuits 1 and 2. b. Low pressure switch shall use different color wire than the high pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 3. High pressure switch. a. Units with 2 compressors shall have different sized connectors for the circuit 1 and circuit 2 low and high pressure switches. They shall physically prevent the cross-- wiring of the safety switches between circuits 1 and 2. b. High pressure switch shall use different color wire than the low pressure switch. The purpose is to assist the installer and service technician to correctly wire and or troubleshoot the rooftop unit. 4. Automatic reset, motor thermal overload protector. 5. Heating section shall be provided with the following minimum protections: a. High temperature limit switches. b. Induced draft motor speed sensor. c. Flame rollout switch. d. Flame proving controls. 23 09 93 Sequence of Operations for HVAC Controls 23 09 93.13 23 09 93.13 23 40 13 Decentralized, Rooftop Units: INSERT SEQUENCE OF OPERATION Panel Air Filters 23 40 13.13 Decentralized, Rooftop Units: 23 40 13.13.A. Standard filter section 1. Shall consist of factory installed, low velocity, disposable 2-- in. thick fiberglass filters of commercially available sizes. 2. Unit shall use only one filter size. Multiple sizes are not acceptable. 3. Filters shall be accessible through an access panel with “no-- tool” removal as described in the unit cabinet section of this specification (23 81 19.13.H). 23 81 19 Self-- Contained Air Conditioners 23 81 19.13 Small-- Capacity Self-- Contained Air Conditioners (580J**04-- 16) 23 81 19.13.A. General 1. Outdoor, rooftop mounted, electrically controlled, heating and cooling unit utilizing a fully hermetic scroll compressor(s) for cooling duty and gas combustion for heating duty. 2. Factory assembled, single-- piece heating and cooling rooftop unit. Contained within the unit enclosure shall be all factory wiring, piping, controls, and special features required prior to field start-- up. 3. Unit shall use environmentally sound, Puron refrigerant. 85 580J 23 09 33 580J 4. Unit shall be installed in accordance with the manufacturer’s instructions. 5. Unit must be selected and installed in compliance with local, state, and federal codes. 23 81 19.13.B. Quality Assurance 1. Unit meets ASHRAE 90.1 minimum efficiency requirements. 2. Unit shall be rated in accordance with AHRI Standards 210/240 and 340/360. 3. Unit shall be designed to conform to ASHRAE 15, 2001. 4. Unit shall be UL-- tested and certified in accordance with ANSI Z21.47 Standards and UL-- listed and certified under Canadian standards as a total package for safety requirements. 5. Insulation and adhesive shall meet NFPA 90A requirements for flame spread and smoke generation. 6. Unit casing shall be capable of withstanding 500-- hour salt spray exposure per ASTM B117 (scribed specimen). 7. Unit casing shall be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 5000-- hour salt spray. 8. Unit shall be designed in accordance with ISO 9001, and shall be manufactured in a facility registered by ISO 9001. 9. Roof curb shall be designed to conform to NRCA Standards. 10. Unit shall be subjected to a completely automated run test on the assembly line. The data for each unit will be stored at the factory, and must be available upon request. 11. Unit shall be designed in accordance with UL Standard 1995, including tested to withstand rain. 12. Unit shall be constructed to prevent intrusion of snow and tested to prevent snow intrusion into the control box up to 40 mph. 13. Unit shake tested to assurance level 1, ASTM D4169 to ensure shipping reliability. 14. High Efficient Motors listed shall meet section 313 of the Energy Independence and Security Act of 2007 (EISA 2007) 23 81 19.13.C. Delivery, Storage, and Handling 1. Unit shall be stored and handled per manufacturer’s recommendations. 2. Lifted by crane requires either shipping top panel or spreader bars. 3. Unit shall only be stored or positioned in the upright position. 23 81 19.13.E. Project Conditions 1. As specified in the contract. 23 81 19.13.F. Operating Characteristics 1. Unit shall be capable of starting and running at 115_F (46_C) ambient outdoor temperature, meeting maximum load criteria of AHRI Standard 210/240 or 340/360 at ± 10% voltage. 2. Compressor with standard controls shall be capable of operation down to 40_F (4_C), ambient outdoor temperatures. Accessory winter start kit is necessary if mechanically cooling at ambient temperatures down to 25_F (-- 4_C). 3. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. 4. Unit shall be factory configured for vertical supply & return configurations. 5. Unit shall be field convertible from vertical to horizontal airflow on all models. No special kit required on 04-- 14 models. Supply duct kit required for 16 size model only 6. Unit shall be capable of mixed operation: vertical supply with horizontal return or horizontal supply with vertical return. 23 81 19.13.G. Electrical Requirements 1. Main power supply voltage, phase, and frequency must match those required by the manufacturer. 23 81 19.13.H. Unit Cabinet 1. Unit cabinet shall be constructed of galvanized steel, and shall be bonderized and coated with a prepainted baked enamel finish on all externally exposed surfaces. 2. Unit cabinet exterior paint shall be: film thickness, (dry) 0.003 inches minimum, gloss (per ASTM D523, 60_F / 16_C): 60, Hardness: H-- 2H Pencil hardness. 3. Evaporator fan compartment interior cabinet insulation shall conform to AHRI Standards 210/240 or 340/360 minimum exterior sweat criteria. Interior surfaces shall be insulated with a minimum 1/2-- in. thick, 1 lb density, flexible fiberglass insulation, neoprene coated on the air side. Aluminum foil-- faced fiberglass insulation shall be used in the gas heat compartment. 4. Base of unit shall have a minimum of four locations for thru-- the-- base gas and electrical connections (factory installed or field installed), standard. 86 87 580J 5. Base Rail a. Unit shall have base rails on a minimum of 2 sides. b. Holes shall be provided in the base rails for rigging shackles to facilitate maneuvering and overhead rigging. c. Holes shall be provided in the base rail for moving the rooftop by fork truck. d. Base rail shall be a minimum of 16 gauge thickness. 6. Condensate pan and connections: a. Shall be a sloped condensate drain pan made of a non-- corrosive material. b. Shall comply with ASHRAE Standard 62. c. Shall use a 3/4” - 14 NPT drain connection, possible either through the bottom or side of the drain pan. Connection shall be made per manufacturer’s recommendations. 7. Top panel: a. Shall be a single piece top panel on 04 thru 12 sizes, two piece on 14 and 16 sizes. 8. Gas Connections: a. All gas piping connecting to unit gas valve shall enter the unit cabinet at a single location on side of unit (horizontal plane). b. Thru-- the-- base capability (1.) Standard unit shall have a thru-- the-- base gas-- line location using a raised, embossed portion of the unit basepan. (2.) Optional, factory approved, water-- tight connection method must be used for thru-- the-- base gas connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 9. Electrical Connections a. All unit power wiring shall enter unit cabinet at a single, factory prepared, knockout location. b. Thru-- the-- base capability. (1.) Standard unit shall have a thru-- the-- base electrical location(s) using a raised, embossed portion of the unit basepan. (2.) Optional, factory approved, water-- tight connection method must be used for thru-- the-- base electrical connections. (3.) No basepan penetration, other than those authorized by the manufacturer, is permitted. 10. Component access panels (standard) a. Cabinet panels shall be easily removable for servicing. b. Unit shall have one factory installed, tool-- less, removable, filter access panel. c. Panels covering control box, indoor fan, indoor fan motor, gas components (where applicable), and compressors shall have molded composite handles. d. Handles shall be UV modified, composite. They shall be permanently attached, and recessed into the panel. e. Screws on the vertical portion of all removable access panel shall engage into heat resistant, molded composite collars. f. Collars shall be removable and easily replaceable using manufacturer recommended parts. 23 81 19.13.I. Gas Heat 1. General a. Heat exchanger shall be an induced draft design. Positive pressure heat exchanger designs shall not be allowed. b. Shall incorporate a direct-- spark ignition system and redundant main gas valve. c. Gas supply pressure at the inlet to the rooftop unit gas valve must match that required by the manufacturer. 2. The heat exchanger shall be controlled by an integrated gas controller (IGC) microprocessor. a. IGC board shall notify users of fault using an LED (light-- emitting diode). b. The LED shall be visible without removing the control box access panel. c. IGC board shall contain algorithms that modify evaporator fan operation to prevent future cycling on high temperature limit switch. d. Unit shall be equipped with anti-- cycle protection with one short cycle on unit flame rollout switch or 4 continuous short cycles on the high temperature limit switch. Fault indication shall be made using an LED. 580J 3. Standard Heat Exchanger construction a. Heat exchanger shall be of the tubular-- section type constructed of a minimum of 20-- gauge steel coated with a nominal 1.2 mil aluminum-- silicone alloy for corrosion resistance. b. Burners shall be of the in-- shot type constructed of aluminum-- coated steel. c. Burners shall incorporate orifices for rated heat output up to 2000 ft (610m) elevation. Additional accessory kits may be required for applications above 2000 ft (610m) elevation, depending on local gas supply conditions. d. Each heat exchanger tube shall contain multiple dimples for increased heating effectiveness. 4. Optional Stainless Steel Heat Exchanger construction a. Use energy saving, direct-- spark ignition system. b. Use a redundant main gas valve. c. Burners shall be of the in-- shot type constructed of aluminum-- coated steel. d. All gas piping shall enter the unit cabinet at a single location on side of unit (horizontal plane). e. The optional stainless steel heat exchanger shall be of the tubular-- section type, constructed of a minimum of 20-- gauge type 409 stainless steel. f. Type 409 stainless steel shall be used in heat exchanger tubes and vestibule plate. g. Complete stainless steel heat exchanger allows for greater application flexibility. 5. Optional Low NOx Heat Exchanger construction a. Low NOx reduction shall be provided to reduce nitrous oxide emissions to meet California’s Air Quality Management District (SCAQMD) low-- NOx emissions requirement of 40 nanograms per joule or less. b. Primary tubes and vestibule plates on low NOx units shall be 409 stainless steel. Other components shall be aluminized steel. 6. Induced draft combustion motor and blower a. Shall be a direct-- drive, single inlet, forward-- curved centrifugal type. b. Shall be made from steel with a corrosion-- resistant finish. c. Shall have permanently lubricated sealed bearings. d. Shall have inherent thermal overload protection. e. Shall have an automatic reset feature. 23 81 19.13.J. Coils 1. Standard Aluminum Fin - Copper Tube Coils: a. Standard evaporator and condenser coils shall have aluminum lanced plate fins mechanically bonded to seamless internally grooved copper tubes with all joints brazed. b. Evaporator coils shall be leak tested to 150 psig, pressure tested to 450 psig, and qualified to UL 1995 burst test at 1775 psig. c. Condenser coils shall be leak tested to 150 psig, pressure tested to 650 psig, and qualified to UL 1995 burst test at 1980 psig. 2. Optional Pre-- coated aluminum-- fin condenser coils: a. Shall have a durable epoxy-- phenolic coating to provide protection in mildly corrosive coastal environments. b. Coating shall be applied to the aluminum fin stock prior to the fin stamping process to create an inert barrier between the aluminum fin and copper tube. c. Epoxy-- phenolic barrier shall minimize galvanic action between dissimilar metals. 3. Optional Copper-- fin evaporator and condenser coils: a. Shall be constructed of copper fins mechanically bonded to copper tubes and copper tube sheets. b. Galvanized steel tube sheets shall not be acceptable. c. A polymer strip shall prevent coil assembly from contacting the sheet metal coil pan to minimize potential for galvanic corrosion between coil and pan. 4. Optional E-- coated aluminum-- fin evaporator and condenser coils: a. Shall have a flexible epoxy polymer coating uniformly applied to all coil surface areas without material bridging between fins. b. Coating process shall ensure complete coil encapsulation of tubes, fins and headers. c. Color shall be high gloss black with gloss per ASTM D523-- 89. d. Uniform dry film thickness from 0.8 to 1.2 mil on all surface areas including fin edges. e. Superior hardness characteristics of 2H per ASTM D3363-- 92A and cross-- hatch adhesion of 4B-- 5B per ASTM D3359-- 93. f. Impact resistance shall be up to 160 in.-- lb (ASTM D2794-- 93). 88 89 580J g. Humidity and water immersion resistance shall be up to minimum 1000 and 250 hours respectively (ASTM D2247-- 92 and ASTM D870-- 92). h. Corrosion durability shall be confirmed through testing to be no less than 1000 hours salt spray per ASTM B117-- 90. 5. Standard All Aluminum Novation Coils: a. Standard condenser coils shall have all aluminum NOVATION Heat Exchanger Technology design consisting of aluminum multi port flat tube design and aluminum fin. Coils shall be a furnace brazed design and contain epoxy lined shrink wrap on all aluminum to copper connections. b. Condenser coils shall be leak tested to 150 psig, pressure tested to 650 psig, and qualified to UL 1995 burst test at 1980 psig. 6. Optional E-- coated aluminum-- fin, aluminum tube condenser coils: a. Shall have a flexible epoxy polymer coating uniformly applied to all coil external surface areas without material bridging between fins or louvers. b. Coating process shall ensure complete coil encapsulation, including all exposed fin edges. c. E-- coat thickness of 0.8 to 1.2 mil with top coat having a uniform dry film thickness from 1.0 to 2.0 mil on all external coil surface areas, including fin edges, shall be provided. d. Shall have superior hardness characteristics of 2H per ASTM D3363-- 00 and cross-- hatch adhesion of 4B-- 5B per ASTM D3359-- 02. e. Shall have superior impact resistance with no cracking, chipping or peeling per NSF/ANSI 51-- 2002 Method 10.2. 23 81 19.13.K. Refrigerant Components 1. Refrigerant circuit shall include the following control, safety, and maintenance features: a. Fixed orifice metering system shall prevent mal-- distribution of two-- phase refrigerant by including multiple fixed orifice devices in each refrigeration circuit. Each orifice is to be optimized to the coil circuit it serves. b. Refrigerant filter drier - Solid core design. c. Service gauge connections on suction and discharge lines. d. Pressure gauge access through a specially designed access port in the top panel of the unit. 2. There shall be gauge line access port in the skin of the rooftop, covered by a black, removable plug. a. The plug shall be easy to remove and replace. b. When the plug is removed, the gauge access port shall enable maintenance personnel to route their pressure gauge lines. c. This gauge access port shall facilitate correct and accurate condenser pressure readings by enabling the reading with the compressor access panel on. d. The plug shall be made of a leak proof, UV-- resistant, composite material. 3. Compressors a. Unit shall use fully hermetic, scroll compressor for each independent refrigeration circuit. b. Compressor motors shall be cooled by refrigerant gas passing through motor windings. c. Compressors shall be internally protected from high discharge temperature conditions. d. Compressors shall be protected from an over-- temperature and over-- amperage conditions by an internal, motor overload device. e. Compressor shall be factory mounted on rubber grommets. f. Compressor motors shall have internal line break thermal, current overload and high pressure differential protection. g. Crankcase heaters shall not be required for normal operating range, unless required by compressor manufacturer due to refrigerant charge limits. 23 81 19.13.L. Filter Section 1. Filters access is specified in the unit cabinet section of this specification. 2. Filters shall be held in place by a pivoting filter tray, facilitating easy removal and installation. 3. Shall consist of factory installed, low velocity, throw-- away 2-- in. thick fiberglass filters. 4. Filters shall be standard, commercially available sizes. 5. Only one size filter per unit is allowed. 23 81 19.13.M. Evaporator Fan and Motor 1. Evaporator fan motor: a. Shall have permanently lubricated bearings. b. Shall have inherent automatic-- reset thermal overload protection or circuit breaker. 580J c. Shall have a maximum continuous bhp rating for continuous duty operation; no safety factors above that rating shall be required. 2. Belt-- driven Evaporator Fan: a. Belt drive shall include an adjustable pitch motor pulley. b. Shall use sealed, permanently lubricated ball-- bearing type. c. Blower fan shall be double-- inlet type with forward-- curved blades. d. Shall be constructed from steel with a corrosion resistant finish and dynamically balanced. 23 81 19.13.N. Condenser Fans and Motors 1. Condenser fan motors: a. Shall be a totally enclosed motor. b. Shall use permanently lubricated bearings. c. Shall have inherent thermal overload protection with an automatic reset feature. d. Shall use a shaft-- down design on 04 to 12 models and shaft-- up on 14 size with rain shield. 2. Condenser Fans: a. Shall be a direct-- driven propeller type fan. b. Shall have aluminum blades riveted to corrosion-- resistant steel spiders and shall be dynamically balanced. 23 81 19.13.O. Special Features Options and Accessories 1. Integrated Economizers: a. Integrated, gear-- driven parallel modulating blade design type capable of simultaneous economizer and compressor operation. b. Independent modules for vertical or horizontal return configurations shall be available. Vertical return modules shall be available as a factory installed option. c. Damper blades shall be galvanized steel with composite gears. Plastic or composite blades on intake or return shall not be acceptable. d. Shall include all hardware and controls to provide free cooling with outdoor air when temperature and/or humidity are below setpoints. e. Shall be equipped with gear driven dampers for both the outdoor ventilation air and the return air for positive air stream control. f. Shall be equipped with low-- leakage dampers, not to exceed 2% leakage at 1 in. wg pressure differential. g. Shall be capable of introducing up to 100% outdoor air. h. Shall be equipped with a barometric relief damper capable of relieving up to 100% return air. i. Shall be designed to close damper(s) during loss-- of-- power situations with spring return built into motor. j. Dry bulb outdoor air temperature sensor shall be provided as standard. Outdoor air sensor setpoint shall be adjustable and shall range from 40 to 100_F / 4 to 38_C. Additional sensor options shall be available as accessories. k. The economizer controller shall also provide control of an accessory power exhaust unit function. Factory set at 100%, with a range of 0% to 100%. l. The economizer shall maintain minimum airflow into the building during occupied period and provide design ventilation rate for full occupancy. A remote potentiometer may be used to override the damper setpoint. m. Dampers shall be completely closed when the unit is in the unoccupied mode. n. Economizer controller shall accept a 2-- 10 Vdc CO2 sensor input for IAQ/DCV control. In this mode, dampers shall modulate the outdoor air damper to provide ventilation based on the sensor input. o. Compressor lockout sensor shall open at 35_F (2_C) and close closes at 50_F (10_C). p. Actuator shall be direct coupled to economizer gear. No linkage arms or control rods shall be acceptable. q. Economizer controller shall provide indications when in free cooling mode, in the DCV mode, or the exhaust fan contact is closed. 2. Two-- Position Damper a. Damper shall be a Two-- Position Damper. Damper travel shall be from the full closed position to the field adjustable %-- open setpoint. b. Damper shall include adjustable damper travel from 25% to 100% (full open). c. Damper shall include single or dual blade, gear driven dampers and actuator motor. d. Actuator shall be direct coupled to damper gear. No linkage arms or control rods shall be acceptable. e. Damper will admit up to 100% outdoor air for applicable rooftop units. f. Damper shall close upon indoor (evaporator) fan shutoff and/or loss of power. g. The damper actuator shall plug into the rooftop unit’s wiring harness plug. No hard wiring shall be required. h. Outside air hood shall include aluminum water entrainment filter. 90 91 580J 3. Manual damper a. Manual damper package shall consist of damper, air inlet screen, and rain hood which can be preset to admit up to 25 or 50% outdoor air for year round ventilation. 4. Perfect Humidity System: a. The Perfect Humidity System shall be factory installed in single stage 580J04-- 07 and two stage 580J08-- 14 models with RTPF (round tube plate tin) condenser coils, and shall provide greater dehumidification of the occupied space by two modes of dehumidification operations in addition to its normal design cooling mode: (1.) Subcooling mode further sub cools the hot liquid refrigerant leaving the condenser coil when both temperature and humidity in the space are not satisfied. (2.) Hot gas reheat mode shall mix a portion of the hot gas from the discharge of the compressor with the hot liquid refrigerant leaving the condenser coil to create a two-- phase heat transfer in the system, resulting in a neutral leaving air temperature when only humidity in the space is not satisfied. (3.) Includes head pressure controller. 5. Head Pressure Control Package a. Controller shall control coil head pressure by condenser fan speed modulation or condenser fan cycling and wind baffles. b. Shall consist of solid-- state control and condenser coil temperature sensor to maintain condensing temperature between 90_F (32_C) and 110_F (43_C) at outdoor ambient temperatures down to - 20_F (-- 29_C). 6. Propane Conversion Kit a. Package shall contain all the necessary hardware and instructions to convert a standard natural gas unit for use with liquefied propane, up to 2000 ft (610m) elevation. b. Additional accessory kits may be required for applications above 2000 ft (610m) elevation. 7. Flue Shield a. Flue shield shall provide protection from the hot sides of the gas flue hood. 8. Condenser Coil Hail Guard Assembly a. Shall protect against damage from hail. b. Shall be either hood style or louvered. 9. Unit-- Mounted, Non-- Fused Disconnect Switch (Available on units with MOCP’s of 80 amps or less): a. Switch shall be factory installed, internally mounted. b. National Electric Code (NEC) and UL approved non-- fused switch shall provide unit power shutoff. c. Shall be accessible from outside the unit. d. Shall provide local shutdown and lockout capability. 10. Convenience Outlet: a. Powered convenience outlet. (1.) Outlet shall be powered from main line power to the rooftop unit. (2.) Outlet shall be powered from line side or load side of disconnect by installing contractor, as required by code. If outlet is powered from load side of disconnect, unit electrical ratings shall be UL certified and rated for additional outlet amperage. (3.) Outlet shall be factory installed and internally mounted with easily accessible 115-- v female receptacle. (4.) Outlet shall include 15 amp GFI receptacles with independent fuse protection. (5.) Voltage required to operate convenience outlet shall be provided by a factory installed step-- down transformer. (6.) Outlet shall be accessible from outside the unit. (7.) Outlet shall include a field installed “Wet in Use” cover. b. Non-- Powered convenience outlet. (1.) Outlet shall be powered from a separate 115/120v power source. (2.) A transformer shall not be included. (3.) Outlet shall be factory installed and internally mounted with easily accessible 115-- v female receptacle. (4.) Outlet shall include 15 amp GFI receptacles with independent fuse protection. (5.) Outlet shall be accessible from outside the unit. (6.) Outlet shall include a field installed “Wet in Use” cover. 580J c. Disconnect Switch Bracket (1.) Provides a pre-- engineered and sized mounting bracket for applications requiring a unit mounted fused disconnect of greater than 100 amps. Bracket assures that no damage will occur to coils when mounting with screws and other fasteners. 11. Flue Discharge Deflector: a. Flue discharge deflector shall direct unit exhaust vertically instead of horizontally. b. Deflector shall be defined as a “natural draft” device by the National Fuel and Gas (NFG) code. 12. Thru-- the-- Base Connectors: a. Kits shall provide connectors to permit gas and electrical connections to be brought to the unit through the unit basepan. b. Minimum of four connection locations per unit. 13. Supply Duct Cover (16 size only): a. Required when field converting the factory standard vertical duct supply to horizontal duct supply configuration. One required per unit. 14. Propeller Power Exhaust: a. Power exhaust shall be used in conjunction with an integrated economizer. b. Independent modules for vertical or horizontal return configurations shall be available. c. Horizontal power exhaust shall be mounted in return ductwork. d. Power exhaust shall be controlled by economizer controller operation. Exhaust fans shall be energized when dampers open past the 0-- 100% adjustable setpoint on the economizer control. 15. Roof Curbs (Vertical): a. Full perimeter roof curb with exhaust capability providing separate air streams for energy recovery from the exhaust air without supply air contamination. b. Formed galvanized steel with wood nailer strip and shall be capable of supporting entire unit weight. c. Permits installation and securing of ductwork to curb prior to mounting unit on the curb. 16. High Altitude Gas Conversion Kit: a. Package shall contain all the necessary hardware and instructions to convert a standard natural gas unit to operate from 2000-- 7000 ft (610 to 2134m) elevation with natural gas or from 0-- 7000 ft (90-- 2134m) elevation with liquefied propane. 17. Outdoor Air Enthalpy Sensor: a. The outdoor air enthalpy sensor shall be used to provide single enthalpy control. When used in conjunction with a return air enthalpy sensor, the unit will provide differential enthalpy control. The sensor allows the unit to determine if outside air is suitable for free cooling. 18. Return Air Enthalpy Sensor: a. The return air enthalpy sensor shall be used in conjunction with an outdoor air enthalpy sensor to provide differential enthalpy control. 19. Indoor Air Quality (CO2) Sensor: a. Shall be able to provide demand ventilation indoor air quality (IAQ) control. b. The IAQ sensor shall be available in duct mount, wall mount, or wall mount with LED display. The setpoint shall have adjustment capability. 20. Smoke detectors (factory installed only): a. Shall be a Four-- Wire Controller and Detector. b. Shall be environmental compensated with differential sensing for reliable, stable, and drift-- free sensitivity. c. Shall use magnet-- activated test/reset sensor switches. d. Shall have tool-- less connection terminal access. e. Shall have a recessed momentary switch for testing and resetting the detector. f. Controller shall include: (1.) One set of normally open alarm initiation contacts for connection to an initiating device circuit on a fire alarm control panel. (2.) Two Form-- C auxiliary alarm relays for interface with rooftop unit or other equipment. (3.) One Form-- C supervision (trouble) relay to control the operation of the Trouble LED on a remote test/reset station. (4.) Capable of direct connection to two individual detector modules. (5.) Can be wired to up to 14 other duct smoke detectors for multiple fan shutdown applications 92 580J 21. Winter start kit a. Shall contain a bypass device around the low pressure switch. b. Shall be required when mechanical cooling is required down to 25_F (-- 4_C). c. Shall not be required to operate on an economizer when below an outdoor ambient of 40_F (4_C). 22. Time Guard a. Shall prevent compressor short-- cycling by providing a 5-- minute delay (±2 minutes) before restarting a compressor after shutdown for any reason. b. One device shall be required per compressor. 93 580J E2011 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/11 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. 94 Catalog No. PDS580J---10 Replaces: PDS580J--- 08
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 2011:02:03 14:41:18-05:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2011:02:03 14:41:18-05:00 Producer : Acrobat Distiller 8.1.0 (Windows) Format : application/pdf Creator : Title : Document ID : uuid:16bcc94f-60c8-4562-9e49-2acd3caee0a1 Instance ID : uuid:81b9749a-05b5-4d6a-adee-c049f39eb3bb Page Count : 94 Author :EXIF Metadata provided by EXIF.tools