Bryant Thermostat Tstatbbps701 Users Manual
Bryant Thermostat TSTATBBPS701 TSTAT701_MANUAL1
TSTATBBPS701 to the manual ea9cc400-c368-429a-8b7d-2b60105b2380
2015-02-02
: Bryant Bryant-Thermostat-Tstatbbps701-Users-Manual-412167 bryant-thermostat-tstatbbps701-users-manual-412167 bryant pdf
Open the PDF directly: View PDF .
Page Count: 25
Download | |
Open PDF In Browser | View PDF |
USERS INFORMATION MANUAL Heating & Cooling Systems MODEL TSTATBBPS701 PROGRAMMABLE DIGITAL THERMOSTAT NOTE TO INSTALLER: This manual must be left with the equipment user. 6:03 Su AUTO 68 Am 70 o COOL 67 HEAT o Heat Pump & Heat Cool 7 Day Programmable 4 Time Periods per Day Auto Changeover Large, Easy To Read Display Thermoglow Backlight Very Easy to Program Programmable Fan No Batteries Required Outdoor Temperature Sensor Available Meets California Title 24 Residential Table Of Contents FRONT PANEL DISPLAY QUICK START Set the clock and go BASIC OPERATION PROGRAMMING 4 Time Periods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY 2 3 5 6 8 12 17 23 CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Residential Light Commercial Systems Carrier Corporation 4/01 TSTATBBPS101 Page 1 Front Panel Backlit LCD Display 6:03 Su AUTO 68 Am 70 Warmer or + Button o COOL 67 HEAT o Cooler or - Button Mode Button Heat or Cool Indicator Red = Heat, Green = Cool Programmable Thermostat 6:03 S AUTO 68 FAN FAN OUTSIDE Page 2 Am OUTSIDE 70 o COOL 67 HEAT o VACATION PROGRAM SET CLOCK MODE VACATION PROGRAM SET CLOCK Display 11 2 9 1 1 10 : 12:00 SMTWTFS 7 88 Am ProgramOn Setup Start Locked Pm 88 ServiceFilter AUTO OFFNight 6 Morning Day Evening 8 Fan On o COOL Outside 88 HEAT o 4 1 5 1 4 3 1 Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire system is turned off. PROGRAM ON - indicates the stored program is enabled to run. Page 8. 2 Clock with Day of the Week Indicates the current time and day. This clock is also used to program the timer periods. Page 5. 3 Room Temperature Display Indicates the current room temperature. 4 Desired Set Temperature Indicates desired room temperature(s). Page 7. Page 3 Display 5 Outside Indication Indicates the temperature displayed is from the optional outside sensor. Page 21. 6 Morning, Day, Evening & Night Indication Indicates the program time period. Page 8-11. 7 Setup Indication Indicates the thermostat is in the programming mode. Page 12. 8 Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool. Page 7. 9 Service Filter Indication Service Filter indicates when the filter should be serviced under normal conditions. Appears after 0 - 1950 hours of blower operation (adjustable). Page 15. 10 Locked Indication Locked appears after the right combination of buttons are pressed, rendering the buttons inoperative. Page 22. 11 Start Indication Start appears when programming timer functions. Page 8. Page 4 Quick Start Set the Clock and Go During Setup & Programming: SET CLOCK Press the SET CLOCK button. : 12:00 Am Setup i Pressing the Up and Down buttons will modify the flashing selection. . (Represented in dark black) Press MODE Setup To adjust the clock or Day use 2 S buttons. Press the SET CLOCK button as above to return to normal operation. SET CLOCK This thermostat is preprogrammed from the factory to operate 1 or 2 Stage equipment without the need for further programming. To optimize the installation of this thermostat follow the instructions in the Advanced Setup section. Page 5 Basic Operation Select Mode The HEAT setting indicates the temperature the room has to reach before the furnace will turn on to heat the room. The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. AUTO will automatically select heat or cool based on room temperature demand. Program On will activate the stored timer operation. (Morning, Day, Evening & Night Periods) OFF indicates both heating and air conditioning systems are turned off. : 12:00 M 70 70 70 70 70 : 12:00 M : 12:00 M AUTO : 12:00 M Pm Pm Pm ProgramOn Pm Day : 12:00 M OFF Pm Page 6 69 72 HEAT o Press MODE o COOL Press MODE 72 o COOL 69 HEAT o Press MODE 73 o COOL 70 HEAT o Press MODE Basic Operation Select Desired Temperature : 12:00 M AUTO 72 70 Pm o In any mode, adjust the desired Set Temperature with COOL 69 HEAT o buttons. Pressing the Up or Down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the Up or Down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Fan Operation : 12:00 S Fan On Press FAN 65 Pm 85 o COOL 55 HEAT o Fan On indicates constant fan operation. This feature is active even if the thermostat is set to Off. Page 7 Programming Press PROGRAM 4 Time Periods Press the PROGRAM button to enter time period programming. Use the back cover Programming Worksheet to help with this section. M Select the day of week (M - S) Press MODE Adjust the start time for Morning. 7M:30 Am Start Morning Press MODE Adjust the cooling setpoint for Morning. (35 - 99 ) 7M:30 Am 74 o COOL Morning Press MODE Adjust the heating setpoint for Morning. (35 - 99 ) 7M:30 Am Morning 74 o COOL 72 HEAT o Continued Page 8 Press MODE Programming Adjust the start time for Day. 4 Time Periods I0M:30 Am Start Day Press MODE Adjust the cooling setpoint for Day. I0M:30 (35 - 99 ) 75 Am o COOL Day Press MODE Adjust the heating setpoint for Day. (35 - 99 ) Adjust the start time for Evening. I0M:30 75 Am COOL 73 HEAT o Day 5M:30 o Pm Press MODE Start Evening Press MODE Adjust the cooling setpoint for Evening. 5M:30 Pm 75 o COOL (35 - 99 ) Press Evening MODE Continued Page 9 Programming Adjust the heating setpoint for Evening. (35 - 99 ) 4 Time Periods 5M:30 75 Pm o COOL 73 HEAT o Evening Press MODE Adjust the start time for Night. I MI :30 Pm Start Night Press MODE Adjust the cooling setpoint for Night. I MI :30 Pm 78 o COOL Night (35 - 99 ) Press MODE Adjust the heating setpoint for Night (35 - 99 ) I MI :30 Am Night 78 o COOL 70 HEAT o Press MODE Continued Page 10 Programming 4 Time Periods The copy command becomes available after programming the entire previous day. Yes Select Yes or No to copy the previous day’s program to this day. No : 18:no T co py If No is selected: If Yes is selected: Press MODE Selecting Yes, then pressing mode will copy the previous day’s program and then will ask the same copy question again. If yes is selected each time, this routine will repeat. If No is selected, as in previous steps, flashing prompts for input will appear for the 4 time periods for the next day. Page 11 Press MODE Advanced Setup MODE PROGRAM Press the Mode button. While holding the Mode, press the Program button to enter Setup screens. Adjust the time of day clock. I2:00 AM NOTE: Each step # is located at the top right corner of the display for easy reference. Setup I Tip: To change hours quickly, press and hold the override button in and press the up or down buttons. Press Setup Mo 2 MODE Select the day of the week. Press Setup On Select residential Heat Pump, On or Off. Off OFF HP O Setup B Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) O 3 MODE 4 MODE Press Press MODE Continued Page 12 Advanced Setup 5 Setup On Select Electric Heat On or Off. (Step 5 only appears if heat pump is off in step 3) OFF Off 88 Adjust the deadband from 1 - 6 degrees. 8If Adjust the minimum difference between cooling & heating setpoints. EH 6 2 7 2 8 6 Cy Setup Setup Press MODE Press MODE COOL HEAT (0 - 6 ) Setup Select the cycles per hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min. Compressor lockout. (d, d1, 2 - 6) Press MODE Press : 0:00 Adjust the programmable fan timer. 0 - 60 minutes. 0:00 = off Setup 9 MODE Fan On Press MODE Continued Page 13 Advanced Setup 7:00 Am On Setup Adjust the programmable fan start time. (step 10 appears only if step 9 is not 0:00) I0 Press Fan On MODE 9:00 Adjust the programmable fan stop time. (step 11 appears only if step 9 is not 0:00) Setup Pm II OFF Press Fan On MODE On Setup LI On Select the display backlight always On, or Off after 8 seconds. Off I2 Press MODE 0 Press Setup I3 Reset the Energy Watch Heat hour counter. HEAT FAN (0 - 1999) Press MODE 0 Press Setup I4 COOL Reset the Energy Watch Cool hour counter. FAN Press (0 - 1999) MODE Continued Page 14 Advanced Setup I5 0 Press Reset the Service Filter counter. This will also remove the Service Filter icon from the display FAN Setup ServiceFilter Press MODE Adjust the number of hours the blower will run before the Service Filter icon appears on the display. 0 = off. 0 Setup I6 ServiceFilter (0 - 1950) Press MODE F C Select thermostat operation in degrees Fahrenheit or Centigrade. F Setup I7 Press MODE Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds. Page 15 FAN Advanced Setup Advanced Setup Table Step # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Description Range Time of day clock set Day of the week Heat Pump Reversing Valve polarity Electric Heat Deadband or Temperature swing Forced minimum difference heat/cool Cycles per hour Programmable Fan Programmable Fan Start Time Programmable Fan Stop Time Thermoglow backlight Energy Watch - Heat Timer Energy Watch - Cool Timer Reset Service Filter icon Service Filter run time set Fahrenheit or Centigrade Page 16 24 hour Sun - Sat Off / On O/B Off / On 1-6 0-6 d, d1, 2 - 6 0:00 - 0:60 24 hour 24 hour Off / On 0 - 1999 0 - 1999 -0 - 1950 F/C Factory Default 12:00 Am Monday Off O Off 1 2 6 0:00 7:00 Am 9:00 Pm On 0 0 -0 F About Advanced Features & Operation MEMORY BACKUP - In the event of a power loss, the thermostat will retain the stored program settings without external power or batteries. 2 STAGE OPERATION - The 2nd Stage of heat or cool is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees. Cooling Heating 2 degrees 2nd Stage turn on 1st Stage turn on Dead Band Heat Setpoint Dead Band Cool Setpoint 2 degrees 1st Stage turn on 2nd Stage turn on MINIMUM HEAT/COOL SETPOINT DIFFERENCE - The Heat and Cool setpoints will not be allowed to come any closer to each other than the value set in Advanced Setup step # 7, on page 13. This minimum difference is enforced during Auto changeover and Program On operation. PROGRAMMABLE FAN - If the Programmable Fan timer is set to a value other than 0:00, the fan will run for the preprogrammed amount of time, page 13, step# 9. The Programmable Fan timer will start the fan at the top of each hour. The Programmable Fan may be active even if the thermostat mode is Off. Steps 10 & 11 restrict the hours in which Programmable Fan may operate. Step# 10, page 14 is the start time and step# 11 is the stop time. Setting the times to the same setting in both steps 10 & 11 will allow Programmable Fan to operate 24 hours a day. Page 17 About Advanced Features & Operation EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press the Up button for 2 seconds. The Cool setpoint display will read ‘EH’. : 12:00 Press for Emergency Heat 73 Am eh o 74 HEAT o FAN During Emergency Heat the thermostat will turn on the fan and the 2nd stage of heat, when there is a demand for heat, locking out the 1st stage compressor. Exiting Emergency Heat is the same as entering. During Emergency Heat only OFF and HEAT are available. ELECTRIC HEAT - Selecting Electric Heat on, page 13, step 5, will cause the thermostat to turn on the fan immediately any time there is a heat demand. Since all gas furnaces control the fan, this feature should be off unless the heater is only electric. Page 18 About Advanced Features & Operation KEYPAD LOCK - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will appear on the display. : 12:00 65 Press all 3 for Keypad Lockout MODE Pm Locked 85 COOL 55 HEAT o To unlock the buttons, again press and hold the Mode button. While holding the Mode button in, press the Up and Down buttons in together. The Locked icon will disappear from the display. Page 19 o About Advanced Features & Operation VACATION MODE - When the thermostat is in Vacation mode, the thermostat will operate under the Vacation time period set points. In order for Vacation mode to become active the thermostat must be in the Program On mode. Vacation mode will take effect when the time clock reaches 12:00am. VACATION Press the VACATION button to enter the vacation programming setup steps. 0 85 55 23 Setup Select the number of days that the Vacation Schedule will be in effect. A value of 0 disables Vacation mode. unoccupied 8y 24 Press MODE Setup unoccupied Adjust the cooling setpoint for Vacation mode. (35 - 99 ) COOL Press 25 Setup unoccupied Adjust the heating setpoint for Vacation mode. (35 - 99 ) MODE HEAT Press VACATION Press the Vacation button to exit the Setup screens. If no buttons are pressed, the display will leave the setup screens after 30 seconds. Page 20 About Advanced Features & Operation DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming 4 Time periods, the thermostat will not allow the Heat setpoint to get closer to the Cool setpoint than the value programmed as the minimum difference in step 7, page 13. When entering the Auto mode from Cool, the Heat and Cool setpoints will remain spread apart by the amount that they were adjusted, prior to entering Auto. For example: If the Cool setpoint was set to 80 while in the Cool mode and the Heat setpoint was adjusted to 70 while in the Heat mode, upon entering the Auto mode the Heat and Cool setpoints would be 80 and 70. Both setpoints would then move up and down together, (in this example spread by 10 degrees), by pressing the up or down buttons. To move the Heat and Cool setpoints closer together, enter the Cool or Heat mode by pressing the Mode button, then adjust the setpoint(s) closer together. Heat is limited to how close it can come to Cool by step 7, page 13. Page 21 About Advanced Features & Operation OUTSIDE SENSOR (Optional Accessory) - When connected to terminals RS+5, RS, & GND on the back of the thermostat, the thermostat will read the temperature from the Outside Sensor when asked to. This thermostat will not control to this sensor, it is only to read outside temperature. To read the temperature from the Outside Sensor, press the Outside button of the thermostat . The display will then only show Outside temperature. Pressing the Outside button will then return the display to normal operation. The Outside Sensor is available in a wired or wireless version. The wired sensor can be connected to the thermostat with up to 500’ of 20 ga. or 300’ of 18 ga. Unshielded, thermostat wire. See the Outside Sensor instructions for further details. FACTORY DEFAULTS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Fan button for 5 sec. All icons will appear. Press and hold in the Fan button until Fd appears. This resets all factory settings. To calibrate room temperature, press the Up and Down arrow buttons simultaneously, twice. At this point use the Up and Down buttons to calibrate room temperature, if needed. Press the Mode button to return to normal operation. NOTE CAUTION ON PAGE 1. Page 22 Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation, whether or not actual use begins on that date, then the product does meet this warranty. A new or remanufactured part, at the manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself; PROVIDED the defective part is returned to the distributor through a qualified servicing dealer. THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer. THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION. LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MANY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY. THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR: 1. Normal maintenance as outlined in the installation and servicing instructions or owners manual including filter cleaning and/or replacement and lubrication. 2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service. 4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of the Manufacturer. 5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use. 6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and Canada. 7. Electricity or fuel costs or increases in electricity or fuel costs from any reason whatsoever including additional or unusual use of supplemental electric heat. 8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary form state to state. Page 23 Programming Worksheet see page 8 DAY PERIOD START TIME COOL HEAT Morning M O N D A Y T U E S D A Y W E D N E S D A Y T H U R S D A Y F R I D A Y S A T U R D A Y S U N D A Y Day Evening Night Morning Copy Mon Tue Day No Evening Yes Night Morning Copy Tue Wed Day No Evening Yes Night Morning Copy Wed Thu Day No Evening Yes Night Morning Copy Thu Fri Day No Evening Yes Night Morning Copy Fri Sat Day No Evening Yes Night Morning Copy Sat Sun Day No Evening Yes Night Printed on recycled paper. P/N 88-307 Rev. 1 Form No. OM17-45 Catalog No. 13TS-TA52
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2003:04:21 13:43:58Z Modify Date : 2003:04:22 10:28:08-05:00 Page Count : 25 Creation Date : 2003:04:21 13:43:58Z Mod Date : 2003:04:22 10:28:08-05:00 Producer : Corel PDF Engine Version 11.633 Author : John B. Peil Metadata Date : 2003:04:22 10:28:08-05:00 Creator : John B. Peil Title : Manual Bryant TSTATBBPS701EXIF Metadata provided by EXIF.tools