Burnham V9A Boiler Brochure
2015-06-08
: Burnham Burnham-V9A-Boiler-Brochure-738058 burnham-v9a-boiler-brochure-738058 burnham pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
V9A Series CAST IRON COMMERCIAL WATER OR STEAM BOILER UP TO 82.7% THERMAL EFFICIENCY 447 TO 2367 MBH INPUT OIL, GAS OR OIL/GAS COMBINATION 30, 50 OR 80 PSI CAST IRON SECTIONAL DESIGN WATER OR STEAM TOP OR REAR VENTING EXCLUSIVE OPTIONAL SBC™ BOILER CONTROL MAXIMIZES SYSTEM EFFICIENCY MENU POWER ENTER LOCKOUT SBC ™ OPTIONAL SBC BOILER CONTROL V9A Series CAST IRON COMMERCIAL WATER OR STEAM BOILER Your Commercial Heating Solution! Available in ten sizes with gross output ratings from 347 to 1900 MBH, the V9A Series fires gas, oil or combination gas/oil and is available equipped with either steam or water trim. The Series V9A has thermal efficiencies up to 82.7% meeting AHRI certification requirements. Cast iron construction, ease of assembly, two venting options and stringent testing methods make the V9A Series boiler by Burnham Commercial your commercial heating solution. American-Made Cast Iron Construction PAGE 2 Burnham Commercial’s unique cast iron formula has an extremely high silicon content, making it stronger and more flexible. It offers better thermal shock resistance and greater heat transfer capabilities than other cast iron products. • MANUFACTURED WITH QUALITY Casting Solutions operates a stateof-the-art foundry, in Zanesville, Ohio, ensuring quality and availability of boiler sections. • C AST IRON NIPPLE DIFFERENCE V9A sections are held together using cast iron nipples, which are well known as being of the highest standard for boiler construction. Unlike gaskets used by many other boiler manufacturers, cast iron nipples are impervious to flue gases, oils, petroleum-based chemicals and other contaminants, which means fewer costly repairs and a longer lasting boiler. Installation & Service Flexibility The cast iron sectional design of the V9A boiler makes it easy to maneuver through doorways and into the boiler room. In addition to being shipped as loose sections, the boiler is available with factory-assembled sections or as a completely packaged and fire-tested unit. Packaged units, fastened to a steel skid, are easily maneuvered through standard 36" x 80" doorways. • HASSLE-FREE SECTION ASSEMBLY V9A boiler sections have reinforced lugs that are used to assemble the sections with individual draw rods resulting in fast, strain-free assembly. The sections can be assembled using two common tools–a 3/4" drive ratchet with a 1-1/16" deep socket and wrench. The sections are surface ground to ensure smooth surface mating. An elastic sealant and fiberglass rope are used on all section joints for a completely sealed and pressure-tight assembly. • E XTENSIVE TESTING METHODS — ASME APPROVED Each boiler section is hydrostatically tested at 2-1/2 times the rated working pressure at the foundry. Factory-assembled sections are tested a second time at 1-1/2 times the rated working pressure. • R EAR OR TOP VENTING As a forced draft boiler, the V9A provides optimum draft for controlled efficiency, eliminating the need for high chimneys or induced draft fans. A unique feature of the V9A boiler is that it can be vented from the rear or the top. This enables easy chimney or sidewall venting for maximum installation flexibility. Top outlet venting saves floor space and reduces installation time and materials. A plugged tapping is provided to make flue outlet pressure readings. V9A Series COMMITMENT TO QUALITY V9A Series — Hot Water or Steam Boiler Maximum Allowable Working Pressure (MAWP): 80 PSI-Water; 15 PSI-Steam Burnham Commercial, “America’s Boiler Company,” has earned a reputation for quality and dependability. Built for a variety of applications, the V9A Series is right for your next job. Front Mounted Controls Top or Rear Outlet For easy adjustment and maintenance With adjustable lock-type damper (not shown); includes plugged tapping for outlet pressure readings Removable Side Jacket Panels Easy access to all cleanouts Cast Iron Vertical Design Vertical flue design with pinned heating surface for maximum heat extraction Optional Tankless Heater Provides domestic hot water Burner Mounting Plate Rear Observation Port MENU POWER ENTER LOCKOUT Individual Draw Rods With reinforced lugs for strain-free assembly SBC Optional SBC Boiler Control Wet Base Cast Iron Nipples 4 Burner Manufacturers Side wall insulation creates improved thermal circulation Ensure the integrity of the section assembly and resist petroleum-based chemicals and flue gases Options to best fit your needs GAS EFFICIENCIES Boiler Model (1) V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A ™ Water Combustion Thermal Efficiency Efficiency 80.0% 82.5% 80.1% 82.5% 80.1% 82.4% 80.1% 82.4% 80.1% 82.3% 80.2% 82.3% 80.2% 82.6% 80.2% 82.2% 80.3% 82.1% 80.3% 82.1% Steam Combustion Thermal Efficiency Efficiency 82.5% 80.0% 82.5% 80.1% 82.4% 80.1% 82.4% 80.1% 82.3% 80.1% 82.3% 80.2% 82.6% 80.2% 82.2% 80.2% 82.1% 80.3% 82.1% 80.3% OIL EFFICIENCIES Water Combustion Thermal Efficiency Efficiency — — 86.0% 82.1% 85.5% 82.4% 85.2% 82.5% 85.1% 82.6% 84.9% 82.6% 84.8% 82.7% 84.8% 82.7% 84.7% 82.7% 84.7% 82.7% Steam Combustion Thermal Efficiency Efficiency — — 86.0% 82.1% 85.5% 82.4% 85.2% 82.5% 85.1% 82.6% 84.9% 82.6% 84.8% 82.7% 84.8% 82.7% 84.7% 82.7% 84.7% 82.7% 3 PAGE With flame observation port Includes plugged tapping for over-fire draft readings (not shown) V9A Series RATINGS & EQUIPMENT LISTING NET I=B=R RATING (2) (3) BURNER INPUT Steam Boiler Boiler Gross Output Water Oil Gas Net Firebox Pressure in Firebox Model (1) H.P. MBH (2) MBH Sq. Ft. MBH (GPH) (4) (MBH) Volume (Cu. Ft.) (In. Wtr. Column) V903A V904A V905A V906A V907A V908A V909A V910A V911A V912A 10.3 14.4 19.3 24.1 28.6 33.2 40.1 45.6 51.2 56.8 347 483 646 808 959 1,110 1,342 1,528 1,714 1,900 260 362 485 606 719 833 1,014 1,168 1,323 1,474 1,083 1,508 2,021 2,525 2,996 3,471 4,225 4,867 5,513 6,142 302 420 562 703 834 965 1,167 1,329 1,490 1,652 N/A 4.2 5.6 7.0 8.3 9.6 11.6 13.2 14.8 16.4 447 606 808 1,010 1,198 1,386 1,674 1,905 2,136 2,367 3.2 4.8 6.4 7.9 9.5 11.0 12.6 14.2 15.7 17.3 0.33 0.38 0.31 0.38 0.36 0.35 0.35 0.40 0.45 0.49 I=B=R Dia. (In.) 7 7 8 8 8 10 10 10 12 12 1. Suffix “S” indicates steam boiler, “W” indicates water boiler. Suffix “G” indicates gas-fired, “O” indicates oil fired and “GO” indicates combination gas/oil fired. 2. Boiler ratings are based on 12.5% CO2 on oil; 9.7% CO2 on gas, and .10 in. water column pressure at boiler flue outlet. 3. I=B=R net ratings shown are based on piping and pick up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water. Consult manufacturer for installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc. 4. The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon. Ratings shown above apply to altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each 1000 feet above sea level. Note: M aximum allowable working pressure (MAWP): Steam: 15 PSI Water – USA: 80 PSI (standard relief valve provided is 50 PSI) (30 PSI and 80 PSI relief valve optional) Water – Canada: 45 PSI (standard relief valve provided is 45 PSI) (30 PSI relief valve optional) PAGE 4 Standard Equipment ALL BOILERS: Sections unassembled, flush insulated jacket, burner mounting plate, burner adapter plate, rear flue outlet damper (top outlet optional), flue canopy, rear observation port cover, target wall (V903A), and miscellaneous plugs, bushing and fittings, L4006B (low fire hold aquastat). STEAM TRIM: 15 PSI safety valve, L404F pressuretrol, gauge glass assembly, steam gauge. WATER TRIM: 50 PSI safety relief valve, L4006A high limit, pressure/temperature gauge. OIL BOILERS: Flange mounted flame retention oil burner furnished with two (2) stage fuel unit, primary control and dual oil valves. GAS BOILERS: Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves, gas-electric ignition with proven gas pilot, flame rod on JR burner, ultra violet flame detector on others, electronic programming controls and components are factory wired in a burner mounted control panel. GAS/OIL BURNERS: Flange mounted combination gas/oil burner with standard controls meeting latest UL requirements, manually operated fuel transfer switch for dual fuel changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet flame detector, electronic programming controls and components are factory wired in a burner mounted control panel. PLEASE CONSULT BURNHAM COMMERCIAL WEBSITE FOR BOILER DIMENSIONAL DATA, PIPING CONFIGURATIONS AND BURNER MODELS/SPECIFICATIONS. Optional Energy Management Interface SBC Control Maximizes system efficiency while providing peer-to-peer network, burner modulation, boiler monitoring and diagnostic displays, outdoor air reset, warm weather shutdown and domestic hot water priority features. Universal Gateway • Can be connected to a building’s Energy Management System (EMS) using simple menu selections and wiring a 4-20mA input. • Connects to EMS using modbus protocol • Optional EMS Gateway to BacNet or LonWorks. • Allows EMS controls to adjust either the SBC central heating setpoint or the firing rate. Optional Equipment Assembled sections; completely packaged (includes manual reset high limit and manual reset low water cutoff); packaged and fire-tested; top outlet flue damper; tankless heaters; side inspection tappings with brass plugs; 30 PSI and 80 PSI safety relief valves (water); combustion and hydronic controls to meet special applications including F.M., I.R.I., and ASME CSD-1. ©2013 Burnham Commercial • P.O. Box 3939, Lancaster, PA 17604 Phone: 888.791.3790 • www.burnhamcommercial.com Form No. PL81401291000-4/13-2.5Mc Printed in the U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2013:05:20 14:43:05-04:00 Metadata Date : 2013:05:20 14:43:29-04:00 Modify Date : 2013:05:20 14:43:29-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:92dead47-1cec-1c46-9af1-f72b8db59ab9 Original Document ID : adobe:docid:indd:5169b3c7-82bb-11df-94da-b1b510992cfe Document ID : xmp.id:438BD5D9262068118083FA66431AE59D Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:03F4A92F40206811822AFC5D3428DE93 Derived From Document ID : xmp.did:F7835B871A2068118083E332750441F2 Derived From Original Document ID: adobe:docid:indd:5169b3c7-82bb-11df-94da-b1b510992cfe Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2013:05:20 14:43:05-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 4 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools