V9A Series RATINGS & EQUIPMENT LISTING V9A Series
CAST IRON COMMERCIAL
WATER OR STEAM BOILER
UP TO 82.7%
THERMAL
EFFICIENCY
447 TO 2367
MBH INPUT
OIL, GAS OR
OIL/GAS
COMBINATION
30, 50 OR 80 PSI
CAST IRON
SECTIONAL DESIGN
WATER OR STEAM
TOP OR REAR
VENTING
EXCLUSIVE
OPTIONAL SBC™
BOILER CONTROL
MAXIMIZES
SYSTEM EFFICIENCY
POWER LOCKOUT
MENU ENTER
SBC™
OPTIONAL SBC
BOILER CONTROL
2
PAGE
V9A Series CAST IRON COMMERCIAL WATER OR STEAM BOILER
Your Commercial Heating Solution!
Available in ten sizes with gross output ratings from 347 to
1900 MBH, the V9A Series res gas, oil or combination gas/oil
and is available equipped with either steam or water trim. The
Series V9A has thermal eciencies up to 82.7% meeting AHRI
certication requirements.
Cast iron construction, ease of assembly, two venting options
and stringent testing methods make the V9A Series boiler by
Burnham Commercial your commercial heating solution.
American-Made Cast Iron Construction
Burnham Commercial’s unique cast
iron formula has an extremely high
silicon content, making it stronger
and more exible. It oers better
thermal shock resistance and greater
heat transfer capabilities than other
cast iron products.
• MANUFACTURED WITH QUALITY
Casting Solutions operates a state-
of-the-art foundry, in Zanesville,
Ohio, ensuring quality and
availability of boiler sections.
• CAST IRON NIPPLE DIFFERENCE
V9A sections are held together using
cast iron nipples, which are well
known as being of the highest
standard for boiler construction.
Unlike gaskets used by many other
boiler manufacturers, cast iron
nipples are impervious to ue
gases, oils, petroleum-based
chemicals and other contaminants,
which means fewer costly repairs
and a longer lasting boiler.
Installation & Service Flexibility
The cast iron sectional design of the V9A boiler makes it easy
to maneuver through doorways and into the boiler room. In
addition to being shipped as loose sections, the boiler is available
with factory-assembled sections or as a completely packaged
and re-tested unit. Packaged units, fastened to a steel skid, are
easily maneuvered through standard 36" x 80" doorways.
• HASSLEFREE SECTION ASSEMBLY
V9A boiler sections have reinforced
lugs that are used to assemble the
sections with individual draw rods
resulting in fast, strain-free assembly.
The sections can be assembled
using two common tools–a 3/4"
drive ratchet with a 1-1/16" deep
socket and wrench. The sections are
surface ground to ensure smooth
surface mating. An elastic sealant
and berglass rope are used on all
section joints for a completely sealed
and pressure-tight assembly.
• EXTENSIVE TESTING METHODS ASME APPROVED
Each boiler section is hydrostatically tested at 2-1/2 times
the rated working pressure at the foundry. Factory-assembled
sections are tested a second time at 1-1/2 times the rated
working pressure.
• REAR OR TOP VENTING
As a forced draft boiler, the V9A
provides optimum draft for
controlled eciency, eliminating
the need for high chimneys or
induced draft fans. A unique
feature of the V9A boiler is that it
can be vented from the rear or the
top. This enables easy chimney or
sidewall venting for maximum
installation exibility. Top outlet
venting saves oor space and
reduces installation time and
materials. A plugged tapping is provided
to make ue outlet pressure readings.
Optional Tankless Heater
Provides domestic hot water
Cast Iron Nipples
Ensure the integrity of the section
assembly and resist petroleum-based
chemicals and ue gases
Cast Iron Vertical Design
Vertical ue design with pinned
heating surface for maximum
heat extraction
Rear Observation Port
Includes plugged tapping for
over-re draft readings (not shown)
Burner Mounting Plate
With ame observation port
Removable Side Jacket Panels
Easy access to all cleanouts
Individual Draw Rods
With reinforced lugs for
strain-free assembly
Wet Base
Side wall insulation creates
improved thermal circulation
4 Burner Manufacturers
Options to best t your needs
Front Mounted Controls
For easy adjustment
and maintenance
3
PAGE
V9A Series COMMITMENT TO QUALITY
Top or Rear Outlet
With adjustable lock-type
damper (not shown); includes
plugged tapping for outlet
pressure readings
Boiler
Model (1)
Water Steam Water Steam
Combustion
Eciency
Thermal
Eciency
Combustion
Eciency
Thermal
Eciency
Combustion
Eciency
Thermal
Eciency
Combustion
Eciency
Thermal
Eciency
V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A
82.5%
82.5%
82.4%
82.4%
82.3%
82.3%
82.6%
82.2%
82.1%
82.1%
80.0%
80.1%
80.1%
80.1%
80.1%
80.2%
80.2%
80.2%
80.3%
80.3%
82.5%
82.5%
82.4%
82.4%
82.3%
82.3%
82.6%
82.2%
82.1%
82.1%
80.0%
80.1%
80.1%
80.1%
80.1%
80.2%
80.2%
80.2%
80.3%
80.3%
—
86.0%
85.5%
85.2%
85.1%
84.9%
84.8%
84.8%
84.7%
84.7%
—
82.1%
82.4%
82.5%
82.6%
82.6%
82.7%
82.7%
82.7%
82.7%
—
86.0%
85.5%
85.2%
85.1%
84.9%
84.8%
84.8%
84.7%
84.7%
—
82.1%
82.4%
82.5%
82.6%
82.6%
82.7%
82.7%
82.7%
82.7%
GAS EFFICIENCIES OIL EFFICIENCIES
Burnham Commercial, “America’s Boiler Company,”
has earned a reputation for quality and dependability.
Built for a variety of applications, the V9A Series is right
for your next job.
V9A Series — Hot Water or Steam Boiler
Maximum Allowable Working Pressure (MAWP):
80 PSI-Water; 15 PSI-Steam
Optional SBC
Boiler Control
POWER LOCKOUT
MENU ENTER
SBC
™
1. Sux “S” indicates steam boiler, “W” indicates water boiler. Sux “G” indicates gas-red, “O” indicates oil red and “GO” indicates combination gas/oil red.
2. Boiler ratings are based on 12.5% CO2 on oil; 9.7% CO2 on gas, and .10 in. water column pressure at boiler ue outlet.
3. I=B=R net ratings shown are based on piping and pick up allowances which vary from 1.333 to 1.289 for steam and 1.15 for water.
Consult manufacturer for installations having unusual piping and pick up requirements, such as intermittent system operation, extensive piping systems, etc.
4. The I=B=R burner capacity in GPH is based on oil having a heat value of 140,000 BTU per gallon.
Ratings shown above apply to altitudes up to 1000 feet on oil and 2000 feet on gas. For altitudes above those indicated, the ratings should be reduced at the rate of 4% for each
1000 feet above sea level.
Note: Maximum allowable working pressure (MAWP):
Steam: 15 PSI
Water – USA: 80 PSI (standard relief valve provided is 50 PSI) (30 PSI and 80 PSI relief valve optional)
Water – Canada: 45 PSI (standard relief valve provided is 45 PSI) (30 PSI relief valve optional)
Form No. PL81401291000-4/13-2.5Mc Printed in the U.S.A.
V9A Series RATINGS & EQUIPMENT LISTING
©2013 Burnham Commercial • P.O. Box 3939, Lancaster, PA 17604
Phone: 888.791.3790 • www.burnhamcommercial.com
4
PAGE
Boiler
Model (1)
Boiler
H.P.
Gross Output
MBH (2)
Steam Water
MBH
Oil
(GPH) (4)
Gas
(MBH)
Net Firebox
Volume (Cu. Ft.)
Pressure in Firebox
(In. Wtr. Column)
I=B=R
Dia. (In.)
MBH Sq. Ft.
V903A
V904A
V905A
V906A
V907A
V908A
V909A
V910A
V911A
V912A
10.3
14.4
19.3
24.1
28.6
33.2
40.1
45.6
51.2
56.8
347
483
646
808
959
1,110
1,342
1,528
1,714
1,900
260
362
485
606
719
833
1,014
1,168
1,323
1,474
1,083
1,508
2,021
2,525
2,996
3,471
4,225
4,867
5,513
6,142
302
420
562
703
834
965
1,167
1,329
1,490
1,652
N/A
4.2
5.6
7.0
8.3
9.6
11.6
13.2
14.8
16.4
447
606
808
1,010
1,198
1,386
1,674
1,905
2,136
2,367
3.2
4.8
6.4
7.9
9.5
11.0
12.6
14.2
15.7
17.3
0.33
0.38
0.31
0.38
0.36
0.35
0.35
0.40
0.45
0.49
7
7
8
8
8
10
10
10
12
12
NET I=B=R RATING 2 3
BURNER INPUT
PLEASE CONSULT BURNHAM COMMERCIAL WEBSITE FOR BOILER DIMENSIONAL DATA, PIPING CONFIGURATIONS AND BURNER MODELS/SPECIFICATIONS.
Standard Equipment
ALL BOILERS: Sections unassembled, ush insulated jacket, burner mounting plate, burner adapter plate, rear ue outlet damper (top outlet optional), ue canopy,
rear observation port cover, target wall (V903A), and miscellaneous plugs, bushing and ttings, L4006B (low re hold aquastat).
STEAM TRIM: 15 PSI safety valve, L404F pressuretrol, gauge glass assembly, steam gauge.
WATER TRIM: 50 PSI safety relief valve, L4006A high limit, pressure/temperature gauge.
OIL BOILERS: Flange mounted ame retention oil burner furnished with two (2) stage fuel unit, primary control and dual oil valves.
GAS BOILERS: Flange mounted gas burner with standard controls meeting the latest UL requirements, dual gas valves, gas-electric ignition with proven gas pilot, ame rod
on JR burner, ultra violet ame detector on others, electronic programming controls and components are factory wired in a burner mounted control panel.
GAS/OIL BURNERS: Flange mounted combination gas/oil burner with standard controls meeting latest UL requirements, manually operated fuel transfer switch for dual fuel
changeover, dual gas valves and oil valves, electric ignition with proven gas pilot on both fuels (direct spark ignition of oil is optional), ultra-violet ame
detector, electronic programming controls and components are factory wired in a burner mounted control panel.
Optional Equipment
Assembled sections; completely packaged (includes manual
reset high limit and manual reset low water cuto); packaged
and re-tested; top outlet ue damper; tankless heaters; side
inspection tappings with brass plugs; 30 PSI and 80 PSI safety
relief valves (water); combustion and hydronic controls to meet
special applications including F.M., I.R.I., and ASME CSD-1.
Optional Energy Management Interface
SBC Control
Maximizes system eciency while providing peer-to-peer network,
burner modulation, boiler monitoring and diagnostic displays, outdoor air
reset, warm weather shutdown and domestic hot water priority features.
Universal Gateway
• Can be connected to a building’s Energy Management System
(EMS) using simple menu selections and wiring a 4-20mA input.
• Connects to EMS using modbus protocol
• Optional EMS Gateway to BacNet or LonWorks.
• Allows EMS controls to adjust either the SBC central heating
setpoint or the ring rate.