CARRIER Controls And HVAC Accessories Manual L0210306
User Manual: CARRIER CARRIER Controls and HVAC Accessories Manual CARRIER Controls and HVAC Accessories Owner's Manual, CARRIER Controls and HVAC Accessories installation guides
Open the PDF directly: View PDF
.
Page Count: 16
| Download | |
| Open PDF In Browser | View PDF |
MicroMetl's discharge 0637 economizer application. is convertible-it will work in either a down discharge or horizontal Read these instructions completely and carefully before beginning installation• ILL. 1 For Down Discharge (for Horizontal Application Compressor Compartment go to page 4) 1. Remove the side panel from the HVAC unit, ILL 1. Discard panel. 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched length 1/2". hole. Maximum screw 3. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/2". Blank-off should fit between top and bottom racks to the far left of HVAC unit. Side Panel with HVAC unit. Remove and discard• Rack Detail Blank-off (If using 1" filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.) ILL. 2 _ jTop filter Evaporator 4. If using 2" wide filter remove spacer. ILL. 3. 5. To change filter: • Open hinged door. • Remove middle filter first. Slide remaining filters to middle of rack for removal. • To install filters, reverse above operation. HVAC unit screw BoSom filter/- #" Spacerfor ILL. 3 Bo_o Screw __ 1" filter (3) 12" X 24" X 1" 2" filter (3) 12" X 24" X 2" Manufacturer reserves the right to disconlJnue,or change at any IJrne,specificaf_ns, designs and pnces without no'dceand without incurnngobliga_ons. Form No. IlK 582A-42-1 / 48/50-10381 Catalog No. 534-80093 Copyright MicroMetl Corporation 2001. All fights reserved. ILL.5 Install additional screw 'l unit flange into replacement panel. Replacement panel. Shipped with economizer Install 3/4" x 1/8" gasket along flange 3/8" " -. I 1/2" flange MicroMetl Install 3/4" x 1/8 28 _/2" economizer bottom gasket along Economizer cover panel 5. Install the replacement panel (shipped with the economizer) HVAC unit. Screw in place through the prepunched holes. over the compressor compartment of the 6. Slide the economizer into the return air chamber, ILL. 5. Slide the economizer as far to the left as possible. The economizer's right side will slightly overlap the bottom filter rack. Be sure economizer is flat. 7. Install gasket and the economizer cover panel over the economizer. Screw in place to the divider in the HVAC unit, base and top. Also, align economizers 3/8" flange to the outside of 1/2" flange as shown and secure economizer cover panel to economizer using provided pre-punched holes with 1" long tek screw. 8. Run the _economizer wiring harness through the grommet in the economizer side and through the HVAC units provided hole located in the upper part of the HVAC unit divider. (Install provided grommet in divider hole.) Follow the enclosed harness routing diagram. (see page 8) 2 g, Screw the rainhood to the economizer panel through prepunched holes. Caulk hood perimeter. (After adjusting the minimum position setting on the actuator, install the 24 3/8" x 19 3/8" aluminum filter in the rain hood.) 11. Remove cover panel shipped over the horizontal return opening. Locate the filter access panel and gasket mating flanges. Install door latch angle, Screw the hinge to the HVAC unit over the horizontal return opening. Adjust the closure handles for a tight seal. 12, Install the provided hinged door. filter access sticker on the kluminum water entrainment filter ILL. 7 Horizontal supply A air cover panel. /" HVAC_ _ SIDE VIEW - Down Discharge Replacement Door latch 13. Be sure the seams are all water tight. Seal as required. angle Filter access door - hinged Aluminum Filter Install filter access door sticker 14. Follow the wiring instructions (see page 7) TOP VIEW enclosed. ILL. 8 Screw panel Compressor Door angle Hinge [] DOOR LATCH ANGLE DETAIL \ Replacement Panel Economizer Hood 3 l-or I-IOrlzonl:al Ulscnarg_e_ (for Down Discharge Application go to page 1) 1. Remove the side panel from the HVAC unit, ILL. 1, discard the panel. Compressor Compartment 2. Install bottom rack. Slide rack over to right side (when facing coil) of HVAC unit. Set rack in front of coil and screw rack to coil frame through pre-punched length 1/2". hole. Maximum screw 3. Install top rack. Slide rack over to right side of HVAC unit. Set rack in front of coil and screw rack to coil frame. Maximum screw length 1/2". Blank-off should fit between top and bottom racks to the far left of HVAC unit. (If using 1" filters, spacer may need to be removed to position blank-off. Once blank-off is in position, re-install spacer.) Side Panel shipped with HVAC unit, Remove and discard 4. If using 2" wide filter remove spacer. ILL. 3. Blank-off \ __ "/ /'-_--_ 5. To change filter: • Remove filter access door on economizer .. ""->_ Top filter rack Evaporator cover panel. • Remove middle filter first. Slide remaining filters to middle of rack for removal. • To install filters, reverse above operation. HVAC unit s( _ws Bo_orn filter/- Rack -_--_,..-_q_ Detail #" ILL. 2 Spacerfor Filter Wiath ILL. 3 BoSom 4 1" filter (3) 12" X 24" X 1" 2" filter (3) 12" X 24" X 2" ILL. 6 Replacement panel with economizer Install additional screw unit flange into replacement panel. ; unit 9 ,, Install 3/4" x 1/8" asket along HVAC divider flange. Economizer panel 7 /16 . Filter access Install 3/4" x 1/8" gasket HVAC bottom 3/4" x 5/8" Casketing, 3 Sides. door 28 1/2" blank-off Screw _ nto base Caulk these corners after economizer is installed 6. Install the replacement prepunched holes. panel over the compressor 7. Install provided economizer punched holes. 8. Install the 3/4 x 5/8" gasketing blank-offto Remove molded gasket from economizer for horizontal application. compartment. bottom of economizer. Screw in place through the Screw in place through the pre- on the bottom flanges of the economizer, ILL. 6. 9. Turn the economizer on its side as shown, ILL. 6. Slide the economizer into the cabinet and as far to the left as possible. The economizer will set against the left side of the HVAC unit. Caulk as required. 10. Install the economizer 11. Align the economizer holes. cover panel over the opening and economizer. to the cover panel with 1" long tek screw using the provided pre-punched NOTE: The relief damper must be sealed shut for the horizontal 5 discharge application. HVAC Unit ILL. 7 Replacement with panel economizer Filter access door for Lpplieation Install filter access door sticker. Rainhood with water entrainment filter 11. Route the economizer wiring harness through the grommet in the economizer side and through the HVAC unit's provided hole located in the upper part of the HVAC unit divider. (Intall provided grommet in divider hole.) Followthe harness routing diagram. (see page 8) 12. Screw the rainhood to the economizer panel through the prepunched holes. Caulk hood perimeter. An extended socket will be required for the left side of the hood. After adjusting the minimum position setting on the actuator, install the aluminum filter in the rainhood. Install the provided filter access sticker on the horizontal filter door. 13. Follow _he wiring instructions, see page 7. 6 i i | The side hinged panel and horizontal cover panel will not be used in the horizontal i applicationl, _Gra DischargeA Orange Sensor ____ Green Equipment Transformer Yellow Brown 0 Green _. White NOTES: J[ Main24V Splice Box Gr_..Lr [ Red /'_ OPTIONAL LOW AMBIENT CONTROL //_ TRANSFORMER IN HVAC UNIT. ..... i .... Z_ POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. z_ MUST BEFINSTALLED ON SUPPLY AIR FAN. 3000 OHM AT 25 C, 77 /.k REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOMETER IS USED z_IS POWERED IS AN ELECTRONIC BY A 24 VAC SWITCH INPUT. WHICH CLOSES WHEN Z_ RELAY 1K & 2K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. Z_ FACTORY INSTALLED 620 OHM, 1 WATT, 5% RESISTOR SHOULD BE REMOVED ONLY IF A SENSOR IS ADDED TO SR AND + FOR DIFFERENTIAL CHANGEOVER. /_ RESISTER ONLY REQUIRED FOR FIXED DRY BULB. Form No. IlK 582A-42-1 / 48/50-103SI Catalog No. 534-80093 ' 1 t I t I t OplJonalRemote Poteni]ometer _] Dry Bulb outside air sensor (or optional enthalpy) n, _Gray Sensor Equipment Transformer Main 24V ,YEtLOW [ IT, AC FUAIOR Ax D_ Bulb Outside Air Sensor (or optional enthalpy) III IZI : n. GO ',',,,,', Ill,, I I _ I I J I NOTES: m Z_ OPTIONAL LOW AMBIENT CONTROL. z_ EQUIPMENTTRANSFORMERMUSTBESIZEDTOACCOMMODATE AN ADDITIONAL 12VA. IF NOT, AN ADDITIONAL OPTIONALTRANSFORMERISREQUIRED. il I I i t POWER SUPPLY. DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Z_ MUST BE INSTALLED IN SUPPLY AIR STREAM. 3000 OHMS AT 25_C, 77eF Z_ REMOVE JUMPER WHEN OPTIONAL REMOTE POTENTIOMETER IS USED /_ lS IS AN ELECTRONIC SWITCH WHICH CLOSES WHEN POWERED BY A 24 VAC INPUT. //_ RELAY 1K & 2K ACTUATE WHEN THE OUTSIDE AIR SENSED BY THE ENTHALPY OR DRY BULB IS LOWER THAN THE SET POINT A-D. FACTORY INSTALLED 620 OHM. 1 WATF, 5% RESISTOR ,_ SHOULD BE REMOVED ONLY IF AN ENTHALPY OR ADJUSTABLE DRY BULB SENSOR IS ADDED TO SR AND + FOR _ DIFFERENTIAL RESISTOR ONLY REQUIRED FOR FIXED DRY BULB. R1 - RELAY IS FIELD SUPPLIED AND FIELD INSTALLED. MOUNT RELAY IN CONTROL BOX, ABOVE INDOOR FAN RELAY Form No. IlK £.n_.A-42-1 / 48/50-103SI Catalog No. 534-80093 WIRING LEGEND U I II LJL_ (_ II I,, _._Z!__Im ',k..... ,,,,, I ,:, ;; iii lli 4% I ] , 1 _ Op'donal Remote ;....... _ Poten_neler iI tl Ii '1[ i I Ill lel L e- ...... ...... I I L .... I L---I 1 I Terminals ___Wire l I 1,I ', I Z_ III I __MMC q I I -I _ I I THERMOSTAT nut or equivalent -- wiring harness Field supplied low voltage wire I [ __L--Field supplied I I I I --Other low voltage wire i connection I I I shock or equipment damage high voltage wire A _'-'--'3 Supply Routing Wiring Harness ACCESSORY SLIDE-IN ECONOMIZER CONTROL INSTALLATION, 1. Unpackage economizer, Main 24V splice box fan/ Discharge sensor. Field 2. Install accessory in unit per installation instructions provided. 3. Remove parts bag and instructions from inside of accessory. 4, Install the discharge sensor in the supply fan section. The sensor must protrude into the supply air stream. 5, Uncoil the wiring harness. Connect the two gray wires of the harness to the discharge sensor leads using the two wire nuts provided. 6. Route the remainder of the wire harness through the unit to the main 24V splice box. 7. Mount thermostat downstairs per the manufacturer's instructions. Run proper wire from the thermostat to the unit control panel. 8, Review the MicroMetl wiring diagram from this booklet. Connect unit, wire from the thermostat and harness from the economizer, together to match the diagram. 9, Follow start-up instructions To.._op_ View Wiring harness. Factory attached to economnzer actuator. Factory run to splice box. Economizer Replacement panel shipped with economizer Damper or enthalpy (optional) Dart module EconOmizer rainhood A "q--'--'J Economizer i Water entrainment filter in hood Economizer harness actuator Economizer rainhoed Main 24V =lice box below. harness 10. Adjust change over setpoint on logic module. Damper actuator and dry bulb or enthalpy Compressor d 1. 2. 3. 4. 5. 6. Discharge sensor. Field install. "A-A"SideView [.:'] 7. 11. Adjust minimum position set point on logic module. Change the thermostat function from HEAT to COOL or leave in AUTO. Drop the comfort setpoint down to engage first stage call for cooling. The first stage cooling call travels to the economizer. If the outdoor air is above the A through D setpoint, (see chart on next page), the first stage mechanical cooling is brought on. As the comfort setpoint is reduced more there will be a second call for cooling which will bring on second stage mechanical cooling if available. 8. In the cooling mode if the outdoor air is below the satpoint, the first stage call for cooling will open the economizer. As the comfort setpoint is reduced more there will be a second call for cooling. This call will bdng on the first stage mechanical cooling to back up the economizer. 9. Once all stages have been cycled, and all adjustments made return thermostat to its proper operating mode, replace all doors, panels and hoods. 10. Leave a copy of these instructions with the customer. After unit is wired begin start-up procedures. Set thermostat functions to OFF. Set comfort levels to minimum cool and minimum heat. Turn unit power on following manufacturer's start up instructions. Turn thermostat fan function to ON. Unit indoor blower should start and damper motor will drive to minimum vent position. Minimum vent position should be adjusted on the economizer logic for the proper percentage of outdoor air. * Switch the thermostat function from OFF to HEAT or AUTO. Bring the comfort setpoint for heat up to engage first stage heating. Follow manufacturer's procedures to check heating cycle. Bring the comfort setpoint for heat up to engage second stage heating if available. Check this heating cycle also. Under no circumstance should the economizer operate in a heating mode except for minium vent position. g These instructions are for fully modulating electronically controlled economizers utilizing solid state logic throughout. A standard single or 1. (recommended) two stage thermostat is all that is needed to complete the control and economizer system for the HVAC equipment. Damper actuator .., 9901-0083 provides 24v modulating control of economizer dampers, 25 in. lb. of torque. (Honeywell M7415A-1006) 2. Ball joint for linkage connection. 3. Discharge sensor ... 9901-0001 provides a signal (3000 Ohms at 25°C or 77°F) to the actuator during free cooling or economizer mode. The signal opens the economizer damper until the discharge temperature drops below 55 ° . At this time the signal causes the motor to modulate the damper and mix outside air with return air to maintain a 50 ° R to 56 ° R discharge temperature. 4. Wire nuts to connect discharge 5. Economizer logic ... 9901-0017 accepts input from discharge _ensor and outside air sensor. Analyzes input to control actuator modulation and economizer switching. Logic also houses minimum position adjustment and enthalpy or adjustable dry bulb adjustment. When used with optional differential sensors in the return air, the logic is capable of selecting the most economical air available for cooling. (Honeywell W7459A-1001) 6. Dry bulb...9901-0183 senses temperature of outside and provides signal to the economizer logic. Opens outside air at 60 °, closes outside air at 70 ° (enthalpy optional). 7. 5/8" grommet fits 5/8" hole that wires may pass through to keep from chaffing. 8. Wire clamps to secure wires to base, dividers, etc.. 9. Wire harness color coded and pre-wired to actuator and economizer logic... 9962-0087. 10. 1/2" hex head screws to secure wire clamps. sensor to the harness. 10 air The purpose of an economizer is to use outdoor air for cooling, whenever possible, to reduce compressor operation. If the fully open actuator cannot satisfy the space demand, mechanical cooling is sequenced on. During the unoccupied period, the actuator will override minimum position setting and drive fully closed. On a loss of power, the actuator will spring return fully closed. The economizer system initially responds to a signal from the cooling thermostat and functions as a true first stage for cooling, while providing maximum fuel economy. The economizer is automatically locked out during the heating mode and holds the outdoor air damper at the minimum position settings. When in heating operation, or when outdoor air temperature or enthalpy (optional) conditions are high, economizer operation is locked out, and actuator During the occupied period, on a call for cooling, when outdoor air temperature or enthalpy (optional) conditions are low, the economizer actuator will proportion thermistor to maintain between discharge sensor. is held at minimum position. The staging relay is used when the first stage compressors must provide mechanical cooling when assisting the economizer. 50 °-F and 56 -oF at If the mixed or discharge temperature is above 56 °- F, actuator will open to admit additional outdoor air until the temperature returns to the 50 °-to 56-° F range. If the mixed or discharge air temperature is below 50 _ F, the actuator will proportion closed, shutting the outdoor air damper until the temperature returns to the 50 -oto 56-o F range. During the occupied period, the actuator will not close past the minimum position. tt The staging relay can be omitted when the second stage compressors can be used to assist the economizer with mechanical cooling. Lvli_ It it It, iI "..-V_L='_((*},Ir "__';i_71_Jf,, [_, [ The minimum position potentiometer keeps the outdoor air damper from closing completely during system operation to provide ventilation, 2. If remote control of dampers is desired, connect the remote potentiometer to P and P and turn it fully clockwise before adjusting the minimum position. 1. Make sure the factory installed jumper is in place across terminals P and P_. 3. Connect 24V AC to system and adjust the potentiometer on the face of the logic module with a screwdriver for desired minimum position. Single enthalpy: The enthalpy changeover setpoints is set to return the outdoor air damper to minimum position when the enthalpy rises above its set point. The enthalpy setpoint scale markings, located on W7459 are A,B,C,D as shown below. The factory-installed 620-ohm lumper must be in place across terminals + and S,_ unless using differential enthalpy. 10 5O 20W ---_13£ I-uJ <;__ d0- lid _O zo: IC uJ:E 40- :_ow _t)> __wO 5oXQ_O e0 ::..i_ O> 0::0 w aw(.9 i . IA T :EwZ : _,_ : :_Wz° _-o 80W (j _ ,,0,< 60- Q:.q 70- wI D 80 ' ' EXAMPLE ENTHALPY Note: The C7650A adjustable dry bulb can also be used for differential change over. Only the temperature of the outdoor air and return air will be compared and the best selected for free cooling. MlcroMeU Call Toll-Free: 1-800-662-4822 Fax: 1-317-543-5986 _ _,1 FOR DETERMINING CONTROL SETTING (1008-0100) i I]'il I_ _[;] il ir_l I[i.] i_1 i[. [_._,_;] dl.."._[_ i,[. |1_ 'i[.] i f; i i i Differential enthalpy control (optional) utilizes two enthalpy sensors connected to one W7459 Economizer Control. The enthalpy setpoint scale markings, located on the W7459, are A,B,C,D. Turn the setpoint potentiometer fully clockwise past the D setting. The economizer will select the air with lower enthalpy for cooling; i.e., if outdoor air has lower enthalpy than return air, then the outdoor air damper will be opened to bring in outdoor air for free cooling. The differential enthalpy connects to S_ and + on the W7959 logic. M LII .% _L''- Enthalpy Changeover Set Point ._.iMinimum Damper Position Setting .._p...--.--LEDLights up to indicate Outdoor Air is Suitable for Free Cooling W7459 Logic Module icroMetlWest Call Toll-Free: 1-800-884-4662 Fax: 1-775-356-9184 Manufac_rer reservesthe rightto discontinue,or change at any time, specifications,designsand priceswithoutno'_ceand withoutincurnngobligations. Copyhght MicroMetl Corporation 2001. All rights reserved. 12 Features: SUBMITTED TO • Economizer can be used in a down or horizontal application. • Fully assembled, easy to install in both down and horizontal application. • Modulating control system factory installed and wired (optional). • Rainhood ships assembled, includes a water entrainment filter and is constructed • Low leak outside air damper. • Barometric relief damper (for down discharge only). • Insulated filler access door is hinged and latched. • Includes filter rack and (3) 12" x 24" x 1"filters. COMPANY: M. HARGIS DRAWN BY: JOB NAME: EQUIPMENT: NOTES: Supply air cover panel shipped on HVAC unit. Carrier Unit No. 48/50GS Economizer 50JS 048-060 P.N. of prepaint steel. Carrier P,N. 0637-0211 48/50GX. 50GL 48GP 042-060 50JX, JZ 042-048 (NOTE 1) CPECOMZR004A00 50JX, JZ 060 0637-0311 CPECOMZR006A00 NOTE: 1. DPDT relay (HN61KK040) for heat pump application is field provided on the 0637-0211. SIDE VIEW Down Discharge Replacement panel shipped with economizer Filters Hinged latched door for down discharge filter access Aluminum water entrainment filter outside air damper THIS OOCUMENT " Economizer's barometnc relief damper (For down discharge only) IS THE PROPERTY OF MICROM ETL CORPORATION MICROMETLCORPORATION*3035N with water entrainment "-.... _,. filter AND IS DELIVER E D UPON THE EXPRESS SHADELANDAVENUE,SUITE300 ° INOIANAPOLIS, CONDITION THAT THE CONTENTS IN 46226*l-800-662-4822_MICROMETLWES WILL NOT BE DISCLOSED O R US ED WITHOUT T°202SOUTH °SPARKS,NV 18THS- MICROMETL'S WRI_ 89431 ol 800-884-466E EN CONSENT 14 15 Ilk 582A-42-1 / 48/50-103SI Catalog No. 534-80093 Page 16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 16 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 12:24:04 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools