Installation Instructions KFADC Downflow Conversion Kit NOTE: Read the entire instruction manual before starting the installation. This symbol --_ indicates a change since the last issue. SAFETY Installing and servicing air conditioning should install or service air conditioning Untrained personnel can pertbnn be performed by trained service labels attached to the unit. Follow all salary Recognize the potential safety codes. information. glasses CAUTION is used due to system and work gloves. This is the sal_ty-alert Use a quenching symbolz_. When pressures and electrical components. coils, or cleaning and replacing equipment, observe precautions cloth lor brazing you see this symbol Only trained personnel filters. All other operations should in the literature, and on tags and operations. Have a fire extinguisher on the unit and instructions or manuals, available. be alert to injury. Understand the signal words DANGER, most serious hazards which will result death. equipment can be hazardous equipment. basic maintenance functions such as cleaning personnel. When working on air conditioning Wear safety for personal CONSIDERATIONS to identify WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the in severe personal injury or death. WARNING signifies hazards which could result in personal injury or unsafe practices which would result in minor personal injury or product and property damage. WARNING: Before beginning any installation or modification, be sure the main electrical disconnect switch is in the OFF position. Tag the disconnect switch with a suitable warning label. Electrical shock can cause personal injury or death. INTRODUCTION Fan coils are factory-shipped tor up flow or horizontal-left applications. This instruction covers the installation of downflow conversion kit on models FA, FB, FC, FK, FX, FV, and PF fan coils and FH fan unit. The kit provides a means of installing fan coils in a downflow position. A-COIL A98437 A90210 -_ Fig. 1--Downflow A-Coil Brackets and Support Strap Location Form: AG-FADC-07 Cancels: AG-FADC-O6 Fig. 2--Position Printed in U.S.A. 2-99 of Angles on A-Coil Catalog No. 63FA-DC2 DESCRIPTION ANDUSAGE The downllow conversion kits are available provide condensate water drainage, conversion 1or slope proper The downflow for use on slope and A-coil versions as well as a means of supporting units requires conversion for A-coil units requires The fan coils are l_ctory complete before NOTE: If unit has electric shipped or horizontal-lefl to ensure heat with a circuit When installed, lor proper the kit will kit part numbers. the t_'_liowing items: l;3r upflow the fan coil unit is positioned fan coils. Instructions ( I) ( 1! (21 (I) Coil bracket Support strap Drainage hole plugs Angle Screws Air seal NOTE: mentioned the lk_llowing items: Coil bracket Coil baffle Screws Foam gasket The downflow of previously the coil. See unit Installation breaker, side access applications. required rel_r 1o electric I2t ( It (21 (2) (41 ! 1) heater INSTALLATION---A-COIL Installation Ik_r installation Installation or the Downflow Convcrsion Kit should be of the coil brackets. [nstructions tbr repositioning of breaker assembly. UNITS ONLY 1. Remove all panels and expose blower and coil areas. 2. Remove any shipping clips securing coil. 3, Remove complete coil/drain pan assembly. 4. Remove and discard horizontal drain pan from coil assembly. 5. Drill four 1/4-in. holes (2 on each side) in fan coil casing at dimples provided. (See Fig. 1.) 6. Secure coil brackets (provided in kit) to casing sides. (See Fig. l.) 7. Install support strap (provided in kit) across front of unit as follows: a. Position flange on each end of strap between coil bracket and casing insulation. (See Fig. 1.) b. Secure support strap ends m coil brackets. (See Fig. 1.) 8. Remove and discard 4 clips (on comers of coil) securing coil assembly to rails for upflow applications. 9. Remove and discard factory-shipped air seal and drain tube assembly. Install l-piece sheet metal air seal assembly provided with kit. 10. Tilt coil assembly back and slide angles (provided in kit) over each inside wall of condensate pan. Pop-riveted flange of angles should extend toward coil. (See Fig. 2.) 11. With fan coil in downflow position, slide coil assembly into unit. (See Fig. 3.) 12. Reinstall all panels. Align holes in panels with tubing and condensate connections. Casing was designed to allow 180 ° rotation of coil access panel and fitting panel. 13. Install 2 plugs that have been provided onto doors to seal unit. SLOPE COIL -3- Fig. 3_Completed A COIL Downflow --2-- Conversion A98442 INSTALLATION--SLOPE I. Remove all panels 2. Remove screw 3. Drill two and expose securing I/4-in. ---)' 5. Secure in downt]ow coil bracket a. Remove b. Align d. Apply in gasket exposed f. Replace top bracket remaining Remove provided complete coil/drain (unit in upflow pan assembly. position). with 2 screws provided. (See Fig. 4.) in top coil bracket. from gasket the gasket. to under of backing side of top coil from gasket must baft'/e at coil end opposite of baffle between bulb must be insulated and press engage the coil tube sheet bracket. (See Fig. 5.) gasket into place. the lanced boles. headers. (See/:Zig. 6,) and end of condensate on slope coils in horizontal pan. Be sure notch right and downflow in baffle applications. is fully seated Failure to insulate below notch in bulb will resu]l loss. 7. Insulate 8, lnverl at dimples onto coil. The 2 screws flange The TXV sensing in perlormance side flange. position. with holes piece coil ONLY Irom coil (2 screws). half of Ioam remaining a. Slide the longer tube sheet. NOTE: side of casing only half of the backing e. Remove 6. Install to right to left side of casing top coil bracket holes c. Remove in right UNITS and coil areas. coil assembly holes 4. Place fan coil unit blower COIL TXV sensing coil assembly 9. Reinstall fitting panel, bulb with cork tape or other and slide it into blower panel, permanent insulating material. unit with drain pan to left side o£ fan coil, Secure and coil access panel. Align holes in panels coil assembly with tubing with screws. and condensate (See Fig. 3.) connections. I I / GASKET TOP BRACKE1 A98438 A98439 SLOPE COIL -> Fig. 4---Downflow Slope Coil --> Fig. 5--Top Coil Bracket Gasket For Slope Coil Only Bracket SLOPE COIL- CONOENSA TE PAN COILBRACKET Fig. 6--COil Baffle Location (At End Opposite Coil Header) --3-- A98440 SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization * Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. CALL FOR FREE CATALOG [ ] Packaged Service Training © 1999 CAC/SDP P.O. Box 70, Indianapolis, IN 46206 agfadc07 1-800-962-9212 [ ] Classroom Service Training _ Book/Tab: 1/3d,4/2e Catalog No. 63FA-DC2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 12:31:10 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools