CARRIER Package Units(both Units Combined) Manual L0709352
User Manual: CARRIER CARRIER Package Units(both units combined) Manual CARRIER Package Units(both units combined) Owner's Manual, CARRIER Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 7
Download | |
Open PDF In Browser | View PDF |
Wall Thermostat Interface Retrofit Kit Accessory For Packaged Terminal Air Conditioner or Heat Pump Cancels: IlK 84-07-7 Installation SAFETY Instructions CONSIDERATIONS INTRODUCTION Only trained, qualified personnel and service mechanics should install electrical accessories on packaged terminal air conditioners or heat pumps. PACKAGE CONTENTS ITEM QUANTITY Wall Thermostat Interface Assembly (Including Control Board, Control Box Door and Knob) Indoor Coil Freeze Thermostat Clip Control Panel Label Wire Ties 1 1 1 2 These instructions cover the installation of the Wall Thermostat Interface Retrofit Kit accessory with Indoor Coil Freeze Therlnostat (IFT) to be installed on packaged temtinal air conditioner (PTAC) products. See Fig. 1. Indoor coil fieeze thermostat protection prevents the indoor coil fiom freezing. The Wall Thermostat Interface Retrofit Kit allows PTAC units to be controlled from a remote thermostat (purchased sep_u'ately). INSTALLATION CONTROLPANEL LABEL Disconnect all power to unit to avoid possible electrical shock during inst_dlation. Prepare WIRE TIES INDOOR COIL THERMOSTAT FREEZE CLIP IlK 84-07-13 9/1/04 CONTROL Unit I. Check to be disconnected. 2. Remove front panel frt)m the unit by grasping the panel firmly near the bottom of both sides, then pulling panel forward and upward to release magnetic latches and p_u'tition hooks. KNOB Remove sure unit Existing is off and Control power to unit is Box 1. Relnove power cord access cover and save screw. See Fig. 2. 2. Remove control knobs and save one for inst_dlation later 3. 4. Open control box by removing the 2 control box cover screws shown in Fig. 2 and swing the cover down to open. Save the screws. Disconnect the power cord by removing the ribbed/white wire at the capacitor (C) terminal, the plain/black wire from the rotguy switch at terminal LI, and both power cord and chassis ground wires from ground screw. See Fig. 3 and 4. Remove wire ties, making sum not to damage the wires, and discard. Remove the power cord and save. WALL THERMOSTAT INTERFACE ASSEMBLY _INDOOR 5. COILFREEZE SENSOR NOTE: Wiring schematic for the Wall Thermostat Interface Retrofit Kit is located in plastic bag on front of control box door Fig. 1 -- Wall Thermostat Interface Retrofit Kit Package Contents Manufacturer reserves the right to discontinue, PC 132 or change Catalog No. 535-20065 at any time, specifications Printed in U.S.A. or designs without notice and without incurring obligations. Form 52C,P-36SI Pg 1 9-04 Replaces: 52C,P-3081 CONTROL BOX COVER SCREWS • POWER CORD ACCESS COVER OUTDOOR THERMOSTAT (OFT) MOUNTING SCREWS CORD Fig. 2 -- Control Box Component Location Select Unit -- Refer to the installation instructions for the unit being retrofit. For Cooling with Electric Heat units see below. For Heat Pump units see page 3. For Cooling Only units see page 5. COOLING WITH ELECTRIC HEAT UNITS 1. Remove the following wires from the rotary switch: a. Yellow wire from COME b. Red fan motor wire from LO, and the black fan motor wire from HI. c. Pink wire from L2. d. Red wire from LS. e. Violet heater wire from HT. 2. Remove the control box door and thermostat bulb from front of coil and discard. 3. Reinstall the previously saved power cord access cover to the new control box door supplied with kit. 4. Attach the new control box door by sliding it onto the control box hinge pins. See Fig. 5. 5. Secure power cord, control board and chassis ground wiles to control box door 6. Attach ribbed/white wire (L2) from power cord to temfinal C on capacitol: See Fig. 4. 7. Reconnect the following wires on control board (see Fig. 6): a. Plain/black wire (LI) from power cord to LI (brass post terminal) on lelay K2. b. Pink wire to L2 on relay K2AI. c. Violet heater wire to Heat2 on lelay K2AI. OUTDOOR COIL FREEZE THERMOSTAT (OFT) RIBBED/WHITE TO CAPACITOR WIRE TIE WIRE TIE _/ GROUND PLAIN/BLACK TO ROTARY SCREW (GND) WIRE (C) WIRE SWITCH (L2) (L1) RED YELLOW_ PINK BLACK BLACK _ INDOOR _ THERMOSTAT Fig. 3 i = ROTARY SWITCH _ Typical Control (Heat Pump Wiring -- Standard Unit Shown) Units NOTE: The male piggy back terminal is not used. This termimd may either be removed or pinched back to fit the connector onto Heat2 relay terminal. d. Red heater wire to Heatl on relay K2. e. Yellow compressor wire to COME on relay KI. 8. Attach the Red fan motor wire to termimd 1 on fan speed selector switch (FSS) and the Black fan motor wile to terminal 3 on FSS. See Fig. 6. 9. Dress wiles using wire ties provided. See Fig. 7. 10. Close the control box door and secure by re-attaching screws saved earliel: 11. Attach control knob that was removed earliel: to fan speed selector switch. 12. Install Indoor Coil Freeze Thermostat (IFT) into coil. a. b. Use a pen to m_ke an opening in the fins to install freeze sensor (Fig. 8). • For 7000 Btuh and 9000 Btuh units, make an opening 4-in. fiom the right side of the coil between the third and fourth row from the top. • For 12,000 Btuh and 15,000 Btuh units, make an opening 4-in. from the right side of the coil between the second and third row fiom the top. Route Indoor Coil Freeze Sensor: • Remove disch;uge deck. See Fig. 8. • Route fieeze sensor fiom PC board through plastic bushing in side panel with electric heater wiles. See Fig. 7. • Push sensor through hole in fi_)nt flange above the _uting plate. See Fig. 9. • Re-install discharge deck. c. Push freeze sensor into opening made in Step 12a. d. Bend clip on scored line and install in fins (the curved notches will lock clips in place) next to sensor to hold sensor in place in the coil. See Fig. 10. 13. Replace front panel. 14. Install control panel label on front of control panel, under door. to cover hole left by removal of control knob. 15. Restore power to unit. HEAT PUMP UNITS WIRE (L2) Fig. 4 -- Capacitor Wiring ATTACHMENT HINGE PINS ATTACHMENT NOTCHES _ ON DOOR ( [/'7--"-"_ %_ BOX --__J / _, / /l \ _-. / Fig. 5 -- Attaching Control Door to PTAC Unit 1. Remove the two mounting screws on the Outdoor Coil Freeze Thermostat (OFT) and save. See Fig. 3. 2. Remove the blue wile from terminal 1 of the OFT. Be sure to re-attach the red wire (that was piggy backed to the blue wire) back on to terminal 1 of file OFT. 3. Remove the black wile from terminal 2 on the OFT. NOTE: The OFT will remain attached to the unit by a capillary tube along with red and yellow wires. The OFT will be reinstalled on the retrofit control box door latec 4. Carefully move the OFT offto the side, taking care not to damage the capillmy tube or wires. 5. Remove the following wiles from the rotary switch: a. Red fan motor wire from LO, and the black fan motor wire from HI. b. Pink wire from L2. c. Violet heater wire and black revel.sing valve wile from HT terminal on rotary switch and separate. d. Remove other black reversing v_dvewire from indoor thermostat termimd 1 (ITI). 6. Remove the control box door and thermostat bulb from front of coil and discard. 7. Reinstall the previously saved power cord access cover to file new control box door supplied with kit. 8. Attach the new control box door by sliding it onto the control box hinge pins. See Fig. 5. 9. Secure power cord, control bomd and chassis ground wires to control box dool: 10. Attach ribbed/white wire (L2) from power cord to terminal C on capacitol: See Fig. 4. 11. Reconnect the following wires on control board (see Fig. 6): a. Plain/black wire (LI) fiom power cord to LI (brass post terminal) on relay K2. b. Pink wire to L2 (brass post terminal) on relay K2AI. c. Violet heater wire to Heat2 on relay K2AI. NOTE: The male piggyback terminal is not used. Either remove or pinch it back in order to fit connector onto Heat2 on relay K2AI. d. One of the 2 black reversing valve wires to RVS (no polarity). e. Remaining black reversing valve wire to L2 (brass post terminal) on relay K2AI. NOTE: Black reversing valve wires me molded together in a 2-wire bundle. 12. Attach md fan motor wire to terminal 1 on Fan Speed Selector switch (FSS) and the black fan motor wire to terminal 3 on FSS. (See Fig. 6.) 13. Attach md wire from Heatl on relay K2 to terminal 2 of OFT. See Fig. 11. 14. Attach yellow wire fiom COMP of relay KI (with piggy back male terlninal) to yellow wire already attached to terminal 3 of OFT. Attach both wires back on terminal 3 of OFT. See Fig. 11. 15. Remount the OFT to the new door with the original screws and in same position and orientation. 16. Dress wires using wire ties provided. See Fig. 7. 17. Close the control box door and secure by re-attaching screws saved earliec 18. Attach control knob that was removed earlier, to fan speed selector switch. VIOLET (HEAT2 ON PLAIN/BLACK (L1 ON K2) K2A1) POWER CORD RED WIRE PINK (L2 ON K2A1) POWER (H EATI_,_,// CORD YELLOW / WIRE // RED WIRE (TERMINAL ON FSS) POWER ACCESS CORD / BLACK POWER CORD ACCESS COVER ATTACHMENT SCREW FAN 1 WIRE SPEED SELECTOR SWITCH (FSS) // THERMOSTAT INTERFACE CONTROL BOARD # Fig. 6 -- Typical Wall Thermostat Interface Board Terminal BUSHING / ELECTRIC WIRES HEATER Connections Control Board Shown) 19. Install Indoor Coil Freeze Thermostat (Ibm) into coil. a. Use a pen to make an opening in the fins to install freeze sensor (Fig. 8). • For 7000 Btuh and 9000 Btuh units, make an opening 4-in. from the right side of the coil between the third and fourth row from the top. b. IFT COIL SENSOR (Heat/Cool • For 12,000 Btuh and 15,000 Btuh units, make an opening 4-in. from file right side of file coil between the second and third row from the top. Route Indoor Coil Freeze Sensor: • Remove dischtuge WIRE TIE deck. See Fig. 8. • Route freeze sensor from PC board through plastic bushing in side panel with electric heater wiles. See Fig. 7. TIE • Push sensor through hole in fiont flange above the rating plate. See Fig. 9. OUTDOOR COIL FREEZE THERMOSTAT (OFT) Fig. 7 -- Completed Assembly (Heat Pump Unit Shown) c. d. • Re-install discharge deck. Push fieeze sensor into opening made in Step 12a. Bend clip on scored line and install in fins (the curved notches will lock clips in place) next to sensor to hold sensor in place in the coil. See Fig. 10. 20. Replace fiont panel. 21. Install control panel label on fiont of control panel, under door, to cover hole left by removal of control knob. 22. Restore power to unit. DISCHARGE DECK Fig. 8 -- Location of Indoor Coil Freeze Thermostat (IFT) on Typical Unit COOLING FRONT FLANGE RATINGPLATE Fig. 9 -- Location of Indoor Thermostat (IFT) with Discharge Coil Freeze Deck Removed ONLY UNITS 1. Remove the yellow wire fiom terminal 1 on indoor thermostat (IT). 2. Remove the red fan motor wire fiom LO, and the black fan motor wire from HI on rotary switch. 3. Remove the control box door and discard. 4. Reinstall the previously saved power cord access cover to the new control box door supplied with kit. 5. Attach the new control box door by sliding it onto the control box hinge pins. See Fig. 5. 6. Secure power cord, control board and chassis ground wiles to control box dool: 7. Attach ribbed/white wire (L2) fiom power cord to temfinal C on capacitol: See Fig. 4. 8. Connect one end of Pink wire (included in plastic bag labeled "For cooling only installations") to the C termimd on the capacitoc Connect the other end to L2 on lelay K2A 1. 9. Reconnect the following wires on control board (see Fig. 6). a. Plain/black wire (LI) from power cord to termimd LI (brass post terminal) on relay K2. b. Yellow compressor wire to COMP on relay KI. 10. Attach red fan motor wire to terminal 1 on Fan Speed Selector switch (FSS) and the black fan motor wile to terminal 3 on FSS. See Fig. 6. 11. Dress wiles using wire ties provided. See Fig. 7. Fig. 10 -- Sensor Clip for Indoor Coil Freeze Thermostat (IFT) on Typical Unit 12. Close file control box door and secure screws saved eafliel: TUBE OFT YELLOW WIRE (TERMINAL 3) YELLOW (TERMINAL RED WIRE (TERMINAL WIRE 3) _ \ RED WIRE (TERMINAL 1) by re-attaching 13. Attach control knob that was removed earliel: to fan speed selector switch. 14. Install Indoor Coil Freeze Thermostat (IF_) into coil. a. Use a pen to make an opening in the fins to install freeze sensor (Fig. 8). • For 7000 Btuh and 9000 Btuh units, make tin opening 4-in. from the right side of the coil between the flfird and fourth row from the top. • For 12,000 Btuh and 15,000 Btuh units, make tm opening 4-in. from file right side of file coil between the second and third row from the top. b. Route Indoor Coil Freeze Sensor: • Remove dischtuge 2) deck. See Fig. 8. • Route freeze sensor from PC board through plastic bushing in side panel with electric heater wiles. See Fig. 7. Fig. 11 -- Outdoor Coil Freeze Thermostat (OFT) on PTAC Heat Pump Units • Push sensor through hole in front flange above the rating plate. See Fig. 9. c. d. • Re-install discharge deck. Push freeze sensor into opening made in Step 12a. Bend clip on scored line and install in fins (the curved notches will lock clips in place) next to sensor to hold sensor in place in file coil. See Fig. 10. 15. Replace front panel. 16. Install control panel label on front of control panel, under door, to cover hole left by removal of control knob. 17. Restore power to unit. Copyright 2004 Carrier Corporation Manufacturer reserves the right to discontinue, PC 132 or change at any time, specifications Catalog No. 535-20065 Printed in U.S.A. or designs without Form 52C,P-36SI notice and without Pg 8 incurring 9-04 obligations, Replaces: 52C,P-30SI
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 7 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Sat Oct 20 09:06:27 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools