CARRIER Package Units(both Units Combined) Manual L0812445
User Manual: CARRIER CARRIER Package Units(both units combined) Manual CARRIER Package Units(both units combined) Owner's Manual, CARRIER Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Installation Instructions NOTE: Read and become SAFETY Installing and fanfiliar with these instructions servicing installation. air-conditioning codes. INTRODUCTION equipment can be pressures and electrical components. Only personnel should install or service air-conditioning equipment. When working equipment, observe the precautions provided labels attached to the unit. all safety beginning CONSIDERATIONS hazardous due to system trained and qualified Follow before Wear safety on air-conditioning in literature, tags, and These instructions Accessory. consists of extension panels, and attached National Electrical of the power protective clothing, local building codes 265v cord cover, and 4 attachment 1--Package screws. Contents QUANTITY Electrical Subbase and 1 2 Side Extension Panels Adjustable Electrical Subbase Accessory 2 adjustable side ITEM glasses, to the unit. Consult Code (NEC) the installation The 265v Electrical the electrical subbase, Table and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature cover Subbase package Power Cord Cover 1 Attachment Screws (black) 4 for special requirements. GENERAL Recognize safety information. This is the safety-alert symbol/_. When you see this symbol on the unit and in instructions manuals, be alert to the potential for personal injury. or Understand these signal words: DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in nfinor personal injury or product and property damage. NOTE is used to highlight suggestions operation. which will result in enhanced installation, reliability, or The 265v Electrical Subbase packaged air conditioner ternfinal Accessory nmst be used whenever or heat pump is installed the in a wall less than 2 in. (50.8 ram) thick, or where wall sleeve extends 4 in. (101.6 ram) or more into room, or for additional support or leveling of air conditioner or heat pump. Wall sleeve must be 3-1/4 in. (82.6 nfininmm The box ram) minimum into room and 3-1/4 in. (82.6 to 5-1/2 in. (139.7 ram) naaxinmm above floor. ram) electrical subbase has a factory-installed electrical junction containing a receptacle for corded packaged ternfinal air conditioner (PTAC) source connections, units, Knockouts are provided for power INSTALLATION IMPORTANT: Refer to chassis nameplate for power source requirements. ELECTRICAL SHOCK HAZARD AND/OR OPERATION AND DAMAGE HAZARD UNIT Failure to follow this warning or death and/or unit operation injury could result in personal and damage. - Follow the National Electrical codes and ordinances. - For personal grounded. Code (NEC) safety, this unit MUST or local - Alunfinum Consult All wiring must BE properly comply Code NOTE: The factory-installed to PTAC building a qualified wiring cord with this unit. may present electrician When unit is in STOP electrical controls. Step 2 --Prepare position, special problems. there is still voltage to electrical receptacle Owner's codes and National all power Manual must match to choose to unit and remove the chassis the correct front panel. wall sleeve. Drill one 1/8 in. (3.18 ram) hole on each side of wall sleeve. If installing plastic sleeve, use locator dimple can be done through on outside of sleeve. Drilling plastic from inside if desired. for assistance. local (NEC). Step 1 --Disconnect use an extension with Electrical plug. Refer subbase. - Protective devices (fuses or circuit breakers) acceptable for unit installations are specified on the nameplate of each unit. - DO NOT Building power source wiring can enter subbase through any conduit knockout hole in bottom of subbase or through the knockouts in the electrical junction box walls. See Fig. 1. the EXTENSION PANELS SHOWN BENT TO FIT ADJUSTABLE SIDE EXTENSION PANELS ATTACHMENT SCREWSUBBASE TO WALL AGAINST WALL _ LOOATOR SLEEVE .... i E. o,OPLE F PANELS SLIDE INTO INSIDE NOTE: OF SUBBASE r_ _ I/ // BOX ATTACHMENT SCREWSUBBASE TO SIDE PANEL LEVELING BOLT _ I/PANELS _/_ _'1/ _ SIDEI _ ZZ Z - ,_ TAB !_ ENGAGEMENT HOLES _J_ - ATTACHMENT ACCESS COVERS RECEPTACLE ADJUSTABLE SIDE EXTENSION SLEEVE SUBBASE TO WALL _ POWER CORD NOTCH LEVELING BOLT SCREW- ATTACHMENT SCREW-SUBBASE TO SIDE PANEL A08513 Fig. 1 - NOTE: If installing metal sleeve, mark location then drill 1/8-in.(3.2 on metal sleeve. ram) holes. See Fig. 2 Electrical of holes on sleeve for hole dimensions Subbase Assembly Step 5 --Bring Step 6 --Take Step 3 --(Optional) Adjustable Side Extension Panels can be Fig. 4 and 5. See Fig. 3, dimension mounting Step 7 --Attach X. Side Extension Panels to subbase screw on each side so that panel end extends in. (50.8 ram) from front of subbase. using one black dimension X plus 2 To adjust side panel, simply bend panel at slot position. See Fig. 1 and 3. NOTE: 1. holes for more exact fit to wall. See Fig. Use engagement INSIDE WALL-_ into the subbase power subbase the subbase junction box See Fig. 4. are aligned, on each side. wires. Replace to wall sleeve. Subbase cover. See has side tabs for Be sure hole on side tab is locator hole on side of sleeve. attach subbase Once to sleeve with one (1) black screw Do not over tighten. See Fig. 1 and 4. Step 8 --Level subbase flush with floor by adjusting beneath each end of subbase. 1/8" (3.2) ATTACH M ENT HOLE FOR METAL SLEEVE leveling bolts INSIDE WALL ------e, WALL SLEEVE DISTANCE X SIDE 1/8" (3.2) ATTACHMENT HOLE electrical connections. to receptacle to the sleeve. lined up with pre-drilled holes for conduit larger, left access cover off and use field supplied wire nuts to connect attached to cover open space left between subbase and wall. Determine the distance from inside wall to front of wall sleeve. Step 4 --Attach power using one of the knockouts 2" (50.8 (BOTH SIDESy _sl II I I I I I I I r- ---- -- 1 3/16_ _1 L/I DE _EXTENSION T ELECTRICAL SUBBASE PANEL ATTACHMENT SCREW 1/2" (12.7)-_" NOTE: Numbers in ( ) are in rnrn NOTE: Numbers I ILl ADJUSTABLE EXTENSION (MOUNTED SIDE PANEL INSIDE SUBBASE) in ( ) are mm A08498 Fig. 2 - Metal Wall Sleeve A08499 Fig. 3 - Optional Adjustable with Electrical Side Extension Subbase Panels EXPLODED VIEW RECEPTACLE ELECTRICAL JUNCTION BOX WITH RECEPTACLE KNOCKOUTS NOTCH ELECTRICAL JUNCTION BOXSEE EXPLODED VIEW FOR ELECTRICAL SUBBASE DETAIL ELECTRICAL CORD POWER W,RES . HOLE TO ATTACH SUBBASE TO SLEEVE (USE 1 ATTACHMENT SUBBASE LEFT POWER ACCESS COVER CORD COVER _:P_" f RECEPTACLE _ RIGHT ACCESS _ HOLE SIDE (USE COVER SCREW) TO ATTACH EXTENSION PANELS 1 ATTACHMENT SCREW A08514 Fig. 4 - Electrical IMPORTANT: Be sure unit is installed before proceeding Subbase to - Exploded View onto the unit basepan, ensuring power cord is completely covered next step. by power cord cover. See Fig. 6. Step 9 --Remove the smaller right access cover from the subbase and plug the power cord into the receptacle. Step 11 --Make sure power cord cover is lined up so that power cord will pass through the rectangular power cord notch. NOTE: Cord should be routed out through notch located on top-front of subbase. U-shaped knockout on receptacle access Step 10 -- Install metal power [Underwriters' Laboratories] the rectangular DO cover. cord NOT remove the See Fig. 1 and 4. cord cover (required and NEC) by hooking by UL Step 12 -- Attach receptacle access cover to subbase 2 black screws provided, capturing end of power See Fig. 4. See Fig. 7 for completed assembly. Step 13 -- Replace front panel and restore power to unit. the cord cover POWER CORD PTAC UNIT / GROUND _ _ \--GRN/YEL - _ SUBBASE UNIT BASEPAN __ _ GRN/YEL_ /2 - with cord cover. RED (208-230V)- ELECTRICAL BOX LEGEND .... Field Supplied (Wire Power Supply) SUBBASE Factory Supplied Wire / / Wire Connector O Component Connection POWER CORD COVER (Unmarked) RECEPTACLE ACCESS COVER SCREWS POWER CORD NOTCH (ON SUBBASE) A08510 Fig. 5 - Electrical Subbase Wiring Diagram A08511 Fig. 6 - Location of Power Cord Cover on Basepan POWER CORD WALL SLEEVE ELECTRICAL SUBBASE LEVELING __ ADJUSTABLE SIDE EXTENSION PANEL BOLT ATTACHMENT SCREW-SUBBASE TO WALL SLEEVE ACCESS POWER CORD COVER COVERS LEVELING BOLT ATTACHMENT SCREWSUBBASE TO SIDE PANEL A08512 Fig. 7 - Electrical Subbase Assembly Copyright 2008 CA( / BDP ° 7310 W. Morris St. ° hldianapolis. IN 46231 Manufacturer reserves the right to change_ at any time_ specifications and Attached to Wall Sleeve Edition Date: 10/08 Printed in U.S.A. designs with Installed without notice and without obligations. 4 Power Cord Cover Catalog No: IIK-SUBB265V-01 Replaces: 52(.P 17S1/535 20039
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Thu Jan 01 04:14:21 2009 Author : Title : Subject :EXIF Metadata provided by EXIF.tools