CARRIER Furnace/Heater, Gas Manual L1002455
User Manual: CARRIER CARRIER Furnace/Heater, Gas Manual CARRIER Furnace/Heater, Gas Owner's Manual, CARRIER Furnace/Heater, Gas installation guides
Open the PDF directly: View PDF .
Page Count: 4
Download | ![]() |
Open PDF In Browser | View PDF |
Installation NOTE: Read installation. the entire SAFETY instruction manual before starting Instructions the CONSIDERATIONS CUT Improper maintenance, installation, adjustment, or use can cause explosion, other conditions property damage. which may cause Consult a qualified alteration, fire, electrical death, personal installer, service service, shock, or injury, agency, or or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions Follow packaged all safety with the kits or accessories codes. Wear safety glasses, HAZARD Failure to follow this caution may result in personal Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces. when installing. protective clothing, and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions include in literature and attached to the unit. Consult local UNIT building Failure to follow this caution dangerous operation. codes, the current editions Code (NFGC) NFPA 54/ANSI Electrical Code (NEC) NFPA 70. of the National Z223.1 and Fuel the refer to the current of Canada Installation CAN/CGA-BI49.1 and .2 Natural Gas and Propane Codes, and Canadian Electrical Code CSA C22.1 Recognize safety information. you manuals, this symbol This is the safety-alert on the unit be alert to the potential Understand CAUTION. DANGER severe see the signal of the National Gas National In Canada, When editions words Standards WARNING, or and These words are used with the safety-alert symbol. identifies the most serious hazards which will result in personal injury or death. WARNING signifies Label all wires controls. hazards This instruction NOTE is used in enhanced covers Use this PSC inducer SHOCK NOTE: wheel, could result in personal injury, Before installing or servicing unit, always turn off main electrical and gas to unit. Lockout and tag with appropriate warning switch. label. There may be more than one disconnect in improper when and servicing of the high output permanent Condensing Gas Furnaces. AND motor kit to replace See Table 1 USAGE a failed inducer motor assembly. the following items: assembly Installation Failure to follow this warning death and/or property damage. disconnection DESCRIPTION Inducer ELECTRICAL to installation PG9MAA and PG9MAB for kit applicability. This kit contains FIRE, EXPLOSION, HAZARD prior may result split capacitor (PSC) inducer motor kit on models 340MAV, 340AAV, 345MAV, 350MAV, 350AAV, 351DAS, 353AAV, 490AAV, 58MCA, 58MCB, 58MEB, 58MSA, 58MXA, 58MXB, which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. to highlight suggestions which will result installation, reliability, or operation. HAZARD INTRODUCTION injury. DANGER, DAMAGE symbol/_. and in instructions for personal iniury. 1 Instructions Inducer motor and vent clamp. 1 assembly mount, inducer consists cover, of motor inducer and fan, capacitor, housing, vent cap, COMBUSTION-AIR -_( INTAKE CONNECTION BURNER ENCLOSURE GAS VALVE AUXILIARY JUNCTION BOX PRIMARY HEAT EXCHANGER (BEHIND CELL INLET PANEL) VENT OUTLET CONDENSING HEAT EXCHANGER (BEHIND CELL INLET PANEL) PRESSURE SWITCH PAM RTV CAP AND CLAMP (UNUSED DRAIN CONNECTION) VENT OUTLET INDUCER MOTOR CONTROL CENTER CONDENSATE, TRAP BLOWER ACCESS PANEL SAFETY INTERLOCK SWITCH MOTOR AND BLOWER ASSEMB_ AIR FILTER AND -RETAINER A98401 Fig. 1 - Inducer Motor Assembly in Upflow Furnace Orientation INSTALLATION Step 1 1 Remove Old Motor A93081 Fig. 2 - Inducer Housing to Collector Box Gasket halogenated hydrocarbons or aromatic contents to prevent inadequate sealing) to inducer housing. Apply a small bead of G.E. RTV 162, G.E. 6702, or Dow-Corning RTV 738 sealant to groove in collector box. G.E. 162 (P771-9003) is available through RCD in 3-oz. tubes. Assembly 1. Turn off gas and electrical supplies to unit. 2. Remove main furnace door. 3. Remove drain tube from inducer motor mounting cover plate. 2. Remove 4 bolts and spacers from old inducer housing assembly. 4. Remove pressure switch tubes. (See Fig. 1.) a. Remove tube attached to pressure switch from collector box. 3. Install spacers in new inducer housing. 4. Insert bolts through inducer housing. b. Remove tube attached to pressure switch from burner enclosure and gas valve. 5. Remove screw securing pressure switch and capacitor to inducer housing. 6. Disconnect motor lead connector at quick-connect. 7. Disconnect vent pipe from inducer housing by loosening coupling clamp on inducer outlet. If coupling has 2 clamps, loosen clamp on vent pipe side. Move pipe out of furnace casing. 8. Using backup wrench, disconnect gas supply pipe from gas valve. 9. Remove wires from gas valve. Note location for reassembly. 10. Remove burner enclosure cover. 11. Remove screws securing manifold to burner enclosure. 12. Remove manifold, orifices, and gas valve as 1 assembly. 13. Remove 4 bolts attaching inducer housing assembly to heat exchanger cell panel. Step 2 1 Install 1. Inspect NOTE: repaired. cooking New Motor seal on collector Assembly box. (See Fig. 2.) If collector box seal is damaged To repair, apply spray or equivalent sealant (must in any way, it must be releasing not contain agent such as PAM corn or canola oil, NOTE: Inserting bolts at this time will add to the ease of their installation later. 5. Install new inducer housing assembly to heat exchanger cell panel by aligning guide pins in collector box. NOTE: Do not pinch collector box pressure tube when assembling inducer housing to collector box. 6. Tighten 4 bolts securing inducer housing assembly to heat exchanger cell panel. 7. Remove screw securing capacitor and reuse to secure pressure switch and capacitor to inducer motor mounting cover plate. 8. Reconnect pressure switch tubes. See tubing label on furnace for proper connections. a. Connect tube from burner enclosure and gas valve to pressure switch. b. Connect tube from collector box to pressure switch. 9. Reconnect motor leads to quick-connect. 10. Reconnect drain tube to inducer motor mounting cover plate. 11. Remove cap and clamp from unused drain connection on old inducer motor mounting cover plate and install on new inducer motor mounting cover plate. 12. Connect vent pipe by inserting pipe through elastomeric (rubber) coupling and then fully into inducer housing outlet. Tighten coupling clamp screw(s) to 15 in.-lb of torque. 16. Reconnect wires to gas valve. gram for proper 17. Turn on gas and electrical CARBON PROPERTY MONOXIDE POISONING DAMAGE HAZARD Failure to follow this warning could iniury, death and/or property damage. result AND 18. Check 14. Replace 15. Using burner a back-up orientation, assembly screws. with gas valve to burner FIRE wrench to prevent rotation supplies to unit. for gas leaks. AND EXPLOSION HAZARD Never check for gas leaks with an open flame. Use a commercially available soap solution made specifically for the detection of leaks to check all connections, box. 19. Check gas supply furnace 20. Reinstall and improper operation main furnace through 2 complete cycles. door. pipe to gas valve. Table 1 - Kit Applicability Fixed Speed Condensing 350AAV 350MAV 353AAV 345MAV 024040 024040 036040 036040 320725-756 024060 036060 048060 320725-756 Furnace Inducer Kits 58MCA 58MCB 58MEB 58MXA 58MXB 58MSA PG9MAA PG9MAB 490AAV 024040 040-08 040-08 040-08 024040 036040 040-12 040-12 040-12 036040 024060 036060 048060 024060 036060 048060 060-08 060-12 060-16 060-08 060-12 060-16 060-08 060-12 060-16 024060 036060 048060 036080 048080 060080 036080 048080 060080 036080 048080 060080 080-12 080-16 080-20 080-12 080-16 080-20 080-12 080-16 080-20 036080 048080 060080 320725-756 048100 060100 048100 060100 048100 060100 100-16 100-20 100-16 100-20 100-16 100-20 048100 060100 320725-757 060120 060120 060120 120-20 120-20 120-20 060120 320725-758 060140 060140 060140 140-20 140-20 140-20 060140 Kit Part Number 320725-756 340AAV 340MAV dia- Failure to follow this warning could result in personal injury, death and/or property damage. box cover. reconnect wiring in personal After completing installation, vent pipe must be installed and fully seated against inducer housing internal stop. Coupling clamp screw(s) must be tightened to 15 in.-lb of torque to prevent disassembly of vent from furnace, and to prevent vent gas and condensate leakage. 13. Reinstall manifold Replace mounting Refer to furnace wire location. 351 DAS 036080 048080 060080 ll Copyright 2009 CA( Manufacturer _BDP • 7310 W. Morris St. • Iudianapolis, reserves the right to change, IN 46231 at any time, specifications and designs Edition Date: 09_09 Printed in U.S.A. without notice and without obligations. 4 Catalo_l Replaces: No: IIK320725-002 IIK320725 001. IIK320725 753 001
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 4 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Thu Mar 04 04:16:24 2010 Author : Title : Subject :EXIF Metadata provided by EXIF.tools