CARRIER Air Cleaner Manual L1003417
User Manual: CARRIER CARRIER Air Cleaner Manual CARRIER Air Cleaner Owner's Manual, CARRIER Air Cleaner installation guides
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
to the expe_
Installation Instructions
NOTE:
install.
Read
the entire
TABLE
instruction
manual
before
starting
the
OF CONTENTS
PAGE
INTRODUCTION
...................................
1
HOW
...................................
1
IT WORKS
SAFETY
CONSIDERATIONS
APPLICATION
.........................
CONSIDERATIONS
....................
1
2
INSTALLATION
....................................
3
START-UP
OPERATION
6
AND
MAINTENANCE
TROUBLESHOOTING
SPECIFICATIONS
WARRANTY
........................
....................................
6
...............................
AND DIMENSIONS
8
.................
......................................
A06377
9
Fig. 1 - GAPAB
11
SAFETY
INTRODUCTION
Improper
Congratulations for selecting the Infinity Air Purifier for your
home comfort system! The Infinity
Air Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Infinity Air Purifier is a cornerstone
of Carrier's Healthy Home Solutions for providing healthier,
cleaner air in your home.
HOW
IT WORKS
The Infinity Air Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Infinity Air Purifier treats
the entire air-stream through a state of the art, three-stage process,
exclusive to Carrier.
In stage one, the particles are electrically charged by a
precision-point ionization array as they enter the Infinity Air
Purifier.
In stage two, the charged particles are electrically attracted to the air
purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
The Infinity Air Purifier is CSA certified for shock and electrical
fire hazard only.
La Infinity Air Purifier certification
risques de choc electrique et.
CSA vise uniquement
les
installation,
Unit
CONSIDERATIONS
adjustment,
alteration,
service,
maintenance,
or use can cause explosion,
fire, electrical
shock,
or other
conditions
which may cause death, personal injury or property
damage.
Consult
a qualified
installer,
service agency
distributor
or branch for information
or assistance. The
or your
qualified
installer or agency must use factory-authorized
kits or accessories
when modifying
this product. Refer to the individual
instructions
packaged with the kits or accessories when installing.
Follow all safety codes.
and work gloves. Have
instructions
thoroughly
included
in literature
building
codes
Wear safety glasses, protective
clothing,
a fire extinguisher
available. Read these
and follow
and attached
and cautions
Consult
local
edition
of the National
Electrical
In Canada, refer to the current
Code CSA C22.1.
editions
of the Canadian
Electrical
Recognize
When
you see this symbol
/_
on
be alert to the potential
for
Code (NEC)
and the current
all warnings
to the unit.
NFPA
safety
70.
information.
the unit and in instructions
personal
iniury.
WARNING,
and
or manuals,
Understand
CAUTION.
the signal
words
DANGER,
These words are used with the
safety-alert
symbol. DANGER
identifies the most serious hazards,
which will result in severe personal iniury or death. WARNING
signifies hazards, which could result in personal iniury or death.
CAUTION
is used to identify unsafe practices, which may result
in minor personal iniury or product and property damage. NOTE
is used to highlight
installation,
reliability,
suggestions
which
or operation.
will
result
in enhanced
Transitions
If the return air duct or fan coil openings do not fit the Infinity
Purifier cabinet openings,
gradual transitions
are recommended
PERSONAL
Failure
INJURY
to follow
HAZARD
this caution
Ozone in concentrations
to health.
may result in personal
above
Des concentrations
d'ozone
etre nocives pour la sante.
reduce
injury.
0.05 PPM may be hazardous
superieures
a 0.05
air turbulence
Turning
H
designed
distribution
CONSIDERATIONS
for use in systems
Air Purifier
should
equipped
in a system
be used
across the face of the air purifier.
Power / Air Flow
Sensor
with an air flow sensor
the fan coil blower is operating
models
GAPABXCC1620,
with a fan coil.
be installed
than 20
should
The Infinity Air Purifier should only be powered when airflow is
present. This model is designed
for use with a fan coil and is
GAPABXCC2420
are designed
VAC power source.
Air Conditioning
The Infinity
No more
If the Infinity Air Purifier is installed adjacent to a 90 degree duct
elbow, turning vanes should be added inside duct to improve air
PPM peuvent
The Infinity Air Purifier is designed for use in the return air duct of
a forced air heating,
cooling,
and ventilation
system.
Models
GAPABXCCI620,
GAPABXCC2020
and GAPABXCC2420
are
specifically
efficiency.
Vanes
Electrical
APPLICATION
and maximize
degrees (about 4 in. per running ft.) of expansion
on each side of the transition fitting.
Air
to
which provides
power
only when
(See Fig. 2). Infinity Air Purifier
GAPABXCC2020,
and
to be powered
from
a 208/230
so that all
the return air is circulated
through the air purifier. It should be
located upstream of the fan coil This will help keep the fan coil
clean and prevent condensation
from forming within the Infinity
Air Purifier.
Humidifiers
An ev@orative
humidifier can be mounted upstream of the Infinity
Air Purifier. It is best to install atomizing humidifiers
downstream
of the air purifier because
hard water salt deposits
droplets may damage the air purifier. If an atomizing
must be mounted
upstream
of the Infinity
Air Purifier,
and water
humidifier
it should
be
mounted
as far upstream as possible (at least 6 ft. recommended),
and a standard
disposable
furnace
filter should
be mounted
between the humidifier
and the air purifier to trap hard water salt
deposits and water droplets.
A06387
Fig. 2 - Air Flow
Door
(xl)
Cabinet
(xl)
Air
Purification
Cartridge
(xl)
Enhancement
Module
Sensor
(xl)
Safety
Screen
(xl)
(x21
(xl)
Installation
Manual
Return
Long
Duct
(x2)
Adapters:
/ Short
Air
Flow
Sensor
(x2)
(x2)
(xl)
Installation
Components
(in bag attached
to power
cord)
A07111
Fig. 3 - Infinity Air Purifier Components
INSTALLATION
Step 1 --
Check Infinity
Air Purifier
c. The location
of the Infinity
Components
Step 3 -- Mount
Failure
INJURY
to follow
may result in personal
injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear
appropriate
protective
clothing
and gloves
when
handling parts.
to the heating
and cooling
c. Remove
the air purifier
from the Infinity
d. Position
cartridge
Air Purifier
remove
Step 2 -- Identify
a. Identify
the return
b. Ensure
NOTE:
all items from the box.
Mounting
a mounting
the cabinet between
for the Infinity
Air Purifier
through
the Infinity
system.
and enhancement
Air Purifier
matches the arrows on the face of the air purifier cartridge.
The Infinity Air Purifier or door can be rotated 180 ° to accommodate
the cabinet orientation.
the fan coil and return
holding
the filter rack should
cabinet.
holes are provided
c. Use return
duct adapters
d. Seal seams with tape or caulking
cabinet has been secured.
to attach return ductwork
after the Infinity
Orientation
A06389
A06388
Vertical
Mounting Cabinet
Air Purifier
Air Purifier
A06384
Upflow
Fig. 4 - Infinity Air Purifier Cabinet
Infinity
is
(See Fig. 6).
A06381
Fig. 5 - Mounting
cabinet
for fan coil attachment.
provided
Horizontal
Mounting Cabinet
air duct
duct may be required.
screws
b. Mounting
A06516
Downflow
module
a. Gasket tape between the fan coil and the air purifier
already factory installed.
in
air duct (see Fig. 4).
airflow direction
The fan coil cabinet
be used to attach the air purifier
Location
orientation
acre-
cabinet.
(see Fig. 4 and 5). A transition
Carefully
be readily
for periodic
b. Remove the existing fan coil filter and discard. Excessive system static pressure may result if the Infinity Air Purifier is
used with other filtration devices.
HAZARD
this caution
should
Cabinet
a. Turn off power
PERSONAL
Air Purifier
cessible. Enough room should be provided
placement of the air purifier cartridges.
Cabinet
For Fan Coils
Horizontal
g
c. Connect
supply
the power
connector
cord and the flow sensor cord to the power
and the flow sensor
connector
(see Fig. 7
and Fig. 8).
o
o
H
A06392
Fig. 6 - Use of Return
ELECTRIC
SHOCK
Failure to follow
or death.
AND UNIT
this warning
A06414
Duct Adapters
DAMAGE
could
Fig. 7 - Flow
Sensor
Cable
Installed
HAZARD
result in personal
injury
Only a trained, experienced
service person should install the
Infinity Air Purifier. A thorough
check of the unit installation
should be completed before unit operation.
Before performing
installation,
service or maintenance
operations on unit, turn off
all power to unit. Tag disconnect switch with lockout tag.
A06413
Fig. 8 - Power
ELECTRICAL
SHOCK
HAZARD
could
NOTE:
Failure to follow
or death.
this warning
result in personal
injury
Before installing
power to system.
or servicing
system, always turn off main
There may be more than 1 disconnect switch.
The power
of the cabinet.
Cord
Installed
cord can be routed
through
Zip ties have been enclosed
the opposite
side
to secure the power cord
to the side of the power supply.
NOTE:
Cable
removed
the
connector
and re-installed
cable
connector
and block-off
plates
will
if the power cord is re-routed.
clamp
should
be tightened
need
to be
Screws on
to 9 in.
- lbs.
torque.
NOTE:
The Infinity
208/230Vac/60
Hz.
NOTE:
[]NIT
DAMAGE
Failure
HAZARD
to follow
this
caution
may
result
in
equipment
damage.
Cabinets will support a maximum
weight of 400 lbs/181 kg
when installed beneath
a vertical furnace or air-handling
unit. When setting furnace on cabinet, do not drop it into
place. Position the furnace correctly on the cabinet to prevent
a corner from slipping down and damaging the cabinet or its
components.
Step 4 -- Wiring
a. Ensure
power
has been removed
from the heating
system.
b. Turn the Infinity
Air Purifier
The Infinity
airflow is present.
power switch
off.
and cooling
Air
Purifier
Air Purifier
An airflow
is
should
sensor
to
be
powered
only be powered
is factory-installed
by
when
(See Fig. 2
and Fig. 11). In order to bypass the airflow sensor, use the special
bypass jumper included in the parts bag. With the bypass jumper in
place,
the air purifier
electrical
d. Attach
line power
will be on
at all times when
connected
(see Fig. 9).
the quick connect
terminals
to the fused power connec-
tor leads (in parts bag attached to power cord) and connect to
incoming field power. Attach the ground ring to fan coil chassis ground.
(See Fig. 10.)
to
ELECTRICALSHOCK
HAZARD
AIR FLOW SENSOR
CABLE OR AIR FLOW SENSOR
BYPASS PLUG MUST BE CONNECTED
TO THE
POWER
SUPPLY
IN ORDER TO ACTIVATE
THE AIR
PURIFIER
Failure to follow this warning could result in personal
iniury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
o
EQUIPMENT
DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
g
This unit cannot be powered directly from blower motor
leads. Voltages can exceed 190 VAC (120v motors). Do not
wire directly to blower motor. Wiring to blower motor will
damage power supply and void warranty.
A06670
Fig. 9 - Airflow Sensor Bypass Plug Installed
AIR PURIFIER
POWER CORD
. TOL1F,ELDPOWERSUPP
GROUND:
_
_
ATTACH TO FAN COIL
GROUND (CHASSIS)
i_-
TO FAN COIL FIELD POWER CONNECTION
CABLE CONNECTOR
TO SECURE POWER CORD
TO FAN COIL CABINET
A06515
Fig. 10 - Fan
Air
Coil Chassis
Ground
Flow Sensor
1) Slide
flow sensor
tabs
into support
bracket
2) Rotate
flow sensor
and clip into bracket
A06412
Fig. 11 - Flow Sensor Install
5
START-UP
AND OPERATION
Checking Air Purifier
ELECTRICAL
HAZARD
owner when it is time to change the Infinity Air Purifier cartridge. This maintenance renfinder can be based on either the
TrueSense
dirty filter algorithm or time. The installer should
use their discretion to select the most appropriate option based
on the initial system static pressure.
Operation
SHOCK
AND
HIGH
TM
Maximizing
VOLTAGE
Failure to follow
or death.
this warning
could result in personal
injury
Before installing
power to system.
switch.
or servicing system, always turn off main
There may be more than one (1) disconnect
a. Attach the Infinity Air Purifier door to the cabinet. A magnet
in the door (see Fig. 12) is used to activate a safety switch in
the power supply when the door is installed. The power supply will not energize the air purifier unless the safety switch is
activated.
Performance
a. Maximum air purification performance is obtained when the
furnace blower is set for continuous operation on the thermostat or Infinity Control.
MAINTENANCE
The Infinity Air Purifier is designed
to require minimal
maintenance. Maintenance is linfited to the replacement of the air
purification
cartridge and inspection/brush
cleaning of the
ionization array. Frequency of air purifier cartridge replacement
and cleaning of the ionization array may vary depending on
ductwork design and local environmental conditions.
To replace the air purifier
following steps:
cartridge,
complete
the
Step 5 -- Turn the heating and cooling system power off.
ELECTRICAL
SHOCK
HAZARD
Failure to follow this warning could result in personal
iniury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
A06379
Fig. 12 - Door
Switch
Step 6 -- Turn the Infinity Air Purifier switch to the off position,
Magnet
Step 7 -- Remove the Infinity Air Purifier door.
b. Turn the HVAC system power on and adjust the thermostat or
Infinity System Control to activate the system fan.
Step 8 -- Slide out the old air purifier cartridge and discard,
c. Turn the Infinity Air Purifier power switch to on position.
d. The power indicator light above the Air Purifier power switch
should illuminate (see Fig. 13).
NOTE:
Make sure that the arrows on the air purifier cartridge
point toward the fan coil. This should be in the same direction as
airflow.
Step 9 -- Install the new air purifier cartridge.
Step 10 -- Replace the Infinity Air Purifier door.
Step 11 -- Turn the Infinity Air Purifier switch to the on position,
Step 12 -- Turn heating and cooling system power on.
At the time of air purifier
cartridge
replacement,
if a
powdery residue is noticed on the tips of the points in
the ionization array, proceed to clean them by
completing
the following steps:
Step 1 -- Turn heating and cooling system power off.
//'_'"
i[.........................................
//
Power Indicator
A06380
Fig. 13 - Power
e. Check to ensure the light goes off when the Infinity Air Purifier power switch is set to off, when the blower goes off, or
when the HVAC system power is turned off.
NOTE: Upon power-up, the light will come on for approximately
5 seconds and if no flow is detected, it will go off. If no air purifier
cartridge is detected, the flow sensor will detect this and turn off
after approximately 7 seconds.
Infinity
ELECTRICAL
SHOCK
HAZARD
Indicator
Control
a. When the Infinity Air Purifier is used with an Infinity Control,
the Infinity Control can be configured to remind the home-
Failure to follow this warning could result in personal
iniury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
Step 2 -- Turn the Infinity Air Purifier
Step 3 -- Remove
Step 4 -- Unplug
connected)
the Infinity
the power
switch
Air Purifier
to the off position,
door.
cord and flow sensor cable (if
from the enhancement
module
9 (See Fig. 7 and 8)
Step 5 -- Slide out the enhancement module assembly and safety
screen.
Step 7 -- Gently
stroke the ionization
each bar with enough
points in the ionization
PERSONAL
Failure
INJURY
to follow
HAZARD
this caution
may result in personal
Sheet metal parts may have sharp edges or burrs. Use care and
wear
appropriate
protective
clothing
and gloves
when
handling parts.
Step 6 -NOTE:
Slide out the Safety Screen
Best cleaning
width (or greater)
14) or vacuum
cleaner with brush
to clean any small accunmlations
points.
If desired,
gently
vacuum
use vacuum
the frame and components
Reconnect
Step 11 -- Replace
of enhancement
to
module.
the Safety Screen.
Step 9 -- Slide in enhancement
Step 10 --
from the tips of the
cleaner with brush attachment
the power
module.
cord and flow sensor
the Infinity Air Purifier
Step 12 --
Turn the Infinity
Step 13 --
Turn heating
Air Purifier
and cooling
cable.
Door
switch to the on position,
system power
on.
and set aside.
tools: 5 inch handle
brush point (synthetic
array. Use a gentle back and forth brushing
motion
Step 8 -- Reinstall
injury.
pins on the top plane of
brush depth to hit front and back tips of the
paint brush with 2 inch
or natural bristle)
(See Fig.
g
attachment.
30 °
POINTS ARE SHARP!
Tip
of point
BE VERY CAREFUL
with
residue
Tip of point
DURING CLEANING.
after
cleaning
A06671
Fig. 14 - Removal
of Deposits
from
Ionization
Pins
TROUBLESHOOTING
NOTE:
A magnet in the door (see Fig. 8) is used to activate a
safety switch in the power supply when the door is installed, The
power
switch
SAFETY
supply will
is activated,
Step 2 -- Check
HAZARD
on (closed)
Failure to follow this caution
equipment damage.
The following
instructions
may result in personal
are for use by qualified
injury
or
personnel
only.
not energize
the air purifier
that the Infinity
Air Purifier
power
the safety
switch is in the
position.
Step 3 -- Confirm
that the fan coil blower
Step 4 -- Confirm
that 208/230
power
unless
supply
connector
is operating.
VAC power is provided.
to the air purifier
Attach
when the fan coil blower
is operating.
NOTE:
Even though power is supplied to the Infinity Air Purifier,
it will not turn on unless the airflow sensor senses airflow or the
airflow sensor's
bypass
Step 5 -- Confirm
H
ELECTRICAL
Failure to follow
or death.
SHOCK
this warning
The following
procedures
Disconnect
power between
bypass
HAZARD
could
result in personal
injury
plug is connected
sensor cable or airflow sensor
to the power
Step 6 -- If still not functioning,
cable and the power
will expose electrical components.
checks and proceed carefully.
plug is inserted,
that the airflow
supply
disconnect
cord from the power
Remove
the enhancement
inspect
the airflow sensor
module
(See Fig. 7).
the airflow sensor
supply.
from the air purifier
cabinet and
(See Fig. 11).
Confirm the airflow sensor is properly seated in its bracket
airflow sensor cable is connected
to the back of the sensor.
The Infinity Air Purifier is equipped with a power indicator light
located on the door (see Fig. 13). This power indicator light will
illuminate when the Infinity Air Purifier door is installed, the
power switch is in the on position, AND the fan coil blower is
running and airflow is sensed. If the power indicator light is not
illuminated, follow the troubleshooting steps below.
Step 1 -- Check that the Infinity Air Purifier door is installed.
Replace
the enhancement
Step 7 -- Reconnect
the airflow sensor
If the power
sensor.
module.
the power cord to the power
disable jumper
indicator
(from
light illuminates,
Install the door onto the air purifier
the "ON"
and the
supply
and insert
parts bag).
then replace the airflow
and turn the power switch
to
position.
Step 8 -- If all of the above steps are completed
and the power
indicator light is still not illuminating,
replace the power supply
the enhancement
module.
within
supply.
the power
Note that there are no serviceable
parts
on
SPECIFICATIONS
AND
Table 1 - Specifications
SPECIFICATIONS
Color
Cabinet
GAPABXCC2020
Metallic
20 Ga. Powder
Electrical
and Dimensions
GAPABXCC1620
Taupe
Material
DIMENSIONS
Taupe
Coated
Steel
20 Ga. Powder
208/230v/60Hz
Maximum
Airflow
(CFM)
Efficiency
Replacement
Cartridge
Initial Pressure Drop
(at maximum
airflow)
DIMENSIONS
Taupe
Steel
15
Equivalent
to MERV
GAPCCCAR2020
.22
GAPABXCC2020
22
Coated
2000
15
Equivalent
to MERV
.22
GAPABXCC2420
18-1/2
B
15-1/8
18-
C
13-1/8
13-1/8
13-1/8
D
17- 5/8
21 - 1/8
24-
5/8
E
19- 3/4
19-
19-
3/4
F
22-1/4
22-1/4
22-1/4
G
11-1/4
11-1/4
11-1/4
3/4
15
GAPCCCAR2420
A
5/8
Steel
208/230v/60Hz
.25
GAPABXCC1620
Metallic
20 Ga. Powder
1800
to MERV
GAPCCCAR1620
(in w.c.)
Coated
208/230v/60Hz
1350
Equivalent
GAPABXCC2420
Metallic
25-1/2
22-1/8
1 3/16"
3/8" (Typical Top & Bottom)
3/16"
1 1/2"
1 3/16"
A06378
Fig. 15 - Dimensions
10
Limited
Warranty
FOR WARRANTY
Contact
SERVICE
the installer.
For help, contact:
PRODUCT
for Air Purifier
OR REPAIR:
You may find the installer's
CAC / BDP, Consumer
REGISTRATION:
name on the equipment
Relations,
You can register
P.O. Box 4808,
or in your Owner's
Syracuse,
Packet.
New York 13221,
Phone 1-800-227-7437
your product online at www.cac-bdp.com.
Model No.
Unit Serial No.
Date of Installation
Installed
by
Name of Owner
Address
of Installation
CAC / BDP (hereinafter
"Company")
warrants this product against failure due to defect in materials or workmanship
under normal use and maintenance
as follows. All warranty periods begin on the date of original installation.
If a part fails due to defect during the applicable warranty period Company
will provide a new or remanufactured
part, at Company's
option, to replace the failed defective part at no charge for the part. Alternatively,
and at its
option, the Company will allow a credit in the amount of the then factory selling price for a new equivalent part toward the retail purchase price of a new
Company product.
Except as otherwise stated herein, those are Company's
exclusive
obligations under this warranty for a product failure. This limited
warranty is subject to all provisions, conditions,
limitations and exclusions
listed below and on the reverse (if any) of this document.
OWNER-OCCUPIED,
RESIDENTIAL
APPLICATIONS
This warranty is to the original purchasing owner and is transferable
only to the extent and as stated in the Warranty
warranty period in years, depending on the part and the claimant, is as shown in the chart below.
GAPA Air Purifier
10* (or 5)
Conditions
and below.
The
10"* (or 5)
* If properly registered within 90 days, otherwise 5 years (except in California and Quebec and other jurisdictions
that prohibit warranty benefits
conditioned
on registration,
registration
is not required to obtain longer warranty periods).
See Warranty Conditions
below.
** If properly transferred within 90 days, otherwise 5 years. See Warranty Conditions below. In California and Quebec and other jurisdictions
that
prohibit warranty benefits conditioned
on registration,
registration
is not required for a transfer and all warranty periods for subsequent
owners are
five years from original installation.
OTHER RESIDENTIAL
APPLICATIONS
(Apartments,
Rental
The warranty period is five (5) years and is not transferable.
OTHER APPLICATIONS
This warranty is non-transferable.
The warranty
period
Properties,
etc.)
is one (1) year on all such applications.
LEGAL REMEDIES
- The owner must notify the Company in writing, by certified or registered letter to CAC / BDP, Warranty Claims, P.O. Box 4808,
Syracuse, New York 13221, of any defect or complaint with the product, stating the defect or complaint
and a specific request for repair, replacement,
or other correction of the product under warranty,
mailed at least thirty (30) days before pursuing any legal rights or remedies.
39004DP452
01/10
11
WARRANTY
CONDITIONS:
1.
To obtain the longer warranty periods as shown in the table under original owner, for the original purchaser, the product must be properly
registered at www.cac-bc_.Lcom
within ninety (90) days d original installation.
In jurisdictions
where warranty terms conditioned
on
registration are prohibited by law, registration is not required and the longer warranty period shown will be apply.
2.
Where a product is installed in a newly constructed home, the date of installation is the date the homeowner purchased the home from the
builder.
3.
If the date of original installation cannot be verified, then the warranty period begins ninety (90) days from the date d product manufacture
(as
indicated by the model and serial number).
Proof of purchase may be required at time of service.
4.
The remainder of the first five years of warranty is freely transferable without registration.
To obtain a transfer of the longer warranty periods
as shown in the table under subsequent owner, a subsequent owner must register the transfer at www.cac-b@.com
within 90 days of the
change in ownership and payment of a transfer fee.
Not applicable in all jurisdictions.
See website for details.
5.
Product must be installed properly and by a licensed HVAC technician.
6.
The warranty applies only to products remaining in their original installation location.
7.
Installation, use, care, and maintenance
must be normal and in accordance with instructions contained in the Installation Instructions, Owner's
Manual and Company's service information.
8.
Defective parts must be returned to the distributor through a registered servicing dealer for credit.
LIMITATIONS
OF WARRANTIES:
ALL
IMPLIED
WARRANTIES
AND/OR
CONDITIONS
{INCLUDING
IMPLIED
WARRANTIES
OR
CONDITIONS
OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR
USE OR PURPOSE) ARE LIMITED TO THE DURATION OF THIS
LIMITED WARRANTY.
SOME STATES
OR PROVINCES
DO NOT ALLOW
LIMITATIONS
ON HOW LONG AN IMPLIED WARRANTY
OR
CONDITION
LASTS, SO THE ABOVE
MAY NOT APPLY
TO YOU.
THE EXPRESS
WARRANTIES
MADE iN THIS WARRANTY
ARE
EXCLUSIVE
AND MAY NOT BE ALTERED
ENLARGED
OR CHANGED
BY ANY DISTRIBUTOR
DEALER
OR OTHER
PERSON
WHATSOEVER.
THIS WARRANTY
1.
2.
3.
DOES NOT COVER:
Labor or other costs incurred for diagnosing,
repairing, removing, installing, shipping, servicing or handling of either defective parts, or
replacement parts, or new units.
Any product purchased over the Internet.
Normal maintenance
as outlined in the installation and servicing instructions or Owner's Manual, including filter cleaning and/or replacement
and lubrication.
4.
5.
Failure, damage or repairs from faulty installation, misapplication,
abuse, improper servicing, unauthorized
alteration or improper operation.
Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical
service.
6.
Failure or damage due to floods, winds, fires, lightning, accidents, corrosive environments
Company.
Parts not supplied or designated by Company, or damages resulting from their use.
Products installed outside the U.S.A. or its territories and Canada.
7.
8.
9.
10.
11.
(rust, etc) or other conditions
beyond the control d
Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever,
including additional or unusual use of
supplemental
electric heat.
Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
ANY SPECIAL
iNDiRECT OR CONSE
UENTIAL PROPERTY OR COMMERCIAL
DAMAGE OF ANY NATURE WHATSOEVER.
states or provinces do not allow the exclusion of incidental or consequential
damages, so the above limitation may not apply to you.
This Warranty
gives you specific
legal rights, and you may also have other rights which vary from state to state or province
Some
to province.
39004DP452
01/10
'c'2010Carrier Corp. • 7310 W. Morris St. • Indianapolis, IN 46231
Printed in China
Edition Date: 02/10
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
12
Catalog
No: GAPAB-3SI
Replaces: GAPAB- 2Sl
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 12 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Wed Mar 31 08:56:21 2010 Author : Title : Subject :EXIF Metadata provided by EXIF.tools